AUGUST, 2019
Softstarter Firmware Upgrade
Contents
1 How to upgrade PSTX firmware 2
1.1 Upgrade PSTX softstarter with CB FW version higher than 1.22.0 2
1.1.1 Preparation 2
1.1.2 Upgrade firmware 3
1.2 Upgrade PSTX softstarter with CB FW version lower than 1.22.0 8
1.2.1 Preparation 8
1.2.2 Backup parameters 9
1.2.3 Upgrade firmware 9
2 How to upgrade PSE firmware 13
2.1 Preparation 13
2.2 Upgrade firmware 13
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 2/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
1 How to upgrade PSTX firmware
The PSTX Softstarter has two firmware; one firmware for PSTX HMI and
one firmware for the PSTX Control Board (CB). The two firmware are in one
zip-package and can be found at ABB Library. It is only published internally
ABB, but sharing to customers is approved. To upgrade the PSTX
softstarter with the firmware, the SoftstarterCare is required. Use the
hyperlinks below to download from the ABB library (only available for ABB
personnel - intranet).
• Firmware Package
• SoftstarterCare
It is also possible to find the PSTX firmware and the SoftstarterCare under
Documents->Software at ABB Library - PSTX Softstarter.
In order to upgrade PSTX, there are two different instructions available
depending on the CB firmware version used. The CB firmware version can
typically be found using the HMI (Menu->System info->Softstarter). If the
HMI cannot be used, connect SoftstarterCare to the PSTX softstarter and
you will find the CB firmware version on Information->DEVICE INFORMATION sheet.
IMPORTANT: If you use SoftstarterCare version 2.2.9 or newer and PSTX CB version 1.36.2 or older, you will not be able to
upgrade if you are running in demo mode. Quit demo mode before upgrade.
1.1 Upgrade PSTX softstarter with CB FW version higher than 1.22.0
IMPORTANT: This instruction shall only be used for softstarters with CB firmware version higher than 1.22.0.
1.1.1 Preparation
a. You need a standard USB cable - “Mini-USB to USB”.
b. Unzip and Install SoftstarterCare on your PC.
Note: Please make sure to install the correct version of the Visual C++ Redistributable for Visual Studio 2015 package prior to installation of Softstarter Care. No matter what type of Windows computer you have, please install the x86 version (32-bits) as Softstarter Care is a 32-bits application. It also applies to 64-bits computers. The file name of the redistributable package to download and install from microsoft.com is vc_redist.x86.exe.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 3/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
c. Unzip the PSTX Firmware Package.
1.1.2 Upgrade firmware
a. Ensure that the PSTX softstarter is disconnected from operational
voltage and control supply voltage (100-250V). It only requires the
power from the USB.
b. Set the PSTX HMI in boot mode.
Hold both the stop and L/R button when connecting the USB cable
between the PC and the PSTX HMI. This will set the HMI in boot
mode and all four LEDs (Ready, Run, Protection and Fault) will be lit.
Release the buttons and verify that all 4 LEDs still are lit.
c. Start SoftstarterCare and confirm that the softstarter is connected.
Windows Start->All programs->ABB-> ABB SoftstarterCare™ - Service Engineer Tool-> SoftstarterCare™ - Service Engineer Tool.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 4/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
d. Click on Firmware upgrade to start the firmware upgrade wizard.
e. Select the firmware (.cab) files previously unzipped during the
preparation and then click Next.
f. Your PSTX softstarter is already in boot mode so click Next to
proceed with the upgrade.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 5/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
g. The softstarter parameters are stored to a specified directory for
allowing user to restore parameters after upgrade.
Click Next to use the default directory and start the firmware
upgrade.
h. The firmware upgrade is now in progress. The upgrade takes up to
15 minutes.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 6/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 7/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
i. Message box asks whether you want to restore parameters or not.
Click Yes to restore parameters.
j. The upgrade is now completed. Click Finish.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 8/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
1.2 Upgrade PSTX softstarter with CB FW version lower than 1.22.0
IMPORTANT: This instruction shall only be used for softstarters with CB firmware version lower than 1.22.0.
SoftstarterCare has very limited support for softstarters with old CB
firmware, i.e. parameters backup/restore is not supported, only firmware
upgrade is supported. In addition to the firmware upgrade instruction of
softstarters with new CB firmware, two additional steps is needed for old
CB firmware in order to not lose parameter setting during firmware
upgrade.
1.2.1 Preparation
a. You need a standard USB cable - “Mini-USB to USB”.
b. You need to connect a jumper cable to the COM2 port in order to set
it in boot mode. Contact softstarters support (se-softstarters-
[email protected]) to order one.
If you don’t have the cable it’s still possible to get into boot mode by
connecting the 3 pins shown in the picture below.
c. Unzip and Install SoftstarterCare on your PC
Note: Please make sure to install the correct version of the Visual C++ Redistributable for Visual Studio 2015 package prior to installation of Softstarter Care. No matter what type of Windows computer you have, please install the x86 version (32-bits) as Softstarter Care is a 32-bits application. It also applies to 64-bits
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 9/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
computers. The file name of the redistributable package to download and install from microsoft.com is vc_redist.x86.exe.
d. Unzip the PSTX Firmware Package CB1.34.7/HMI1.16.6.
1.2.2 Backup parameters
Write down all modified parameters. These parameters must be manually
restored after firmware upgrade.
To list the modified parameters, use the HMI and navigate to Menu->Parameters->Modified. If the HMI cannot be used for some reason, then it
is possible to connect another HMI to the PSTX softstarter to list the
modified parameters.
1.2.3 Upgrade firmware
a. Ensure that the PSTX softstarter is disconnected from operational
voltage and control supply voltage (100-250V). It only requires the
power from the USB.
b. Attach jumper cable to Control Board (Jumper cable will force PSTX
CB to boot mode when it is power on)
c. Set the PSTX HMI in boot mode.
Hold both the stop and L/R button when connecting the USB cable
between the PC and the PSTX HMI. This will set the HMI in boot
mode and all four LEDs (Ready, Run, Protection and Fault) will be lit.
Release the buttons and verify that all 4 LEDs still are lit.
d. Remove jumper cable. The Control Board will need to restart itself
into application mode during the upgrade, and that’s not possible if
the jumper cable remains connected to the COM2 port.
e. Start SoftstarterCare, Windows Start->All programs->ABB-> ABB SoftstarterCare™ - Service Engineer Tool-> SoftstarterCare™ - Service Engineer Tool.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 10/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
You will get the following information dialog. Click OK.
f. Click on Firmware upgrade
g. Select the firmware (.cab) files previously unzipped during the
preparation and then click Next.
h. Your PSTX softstarter is already in boot mode so click Next to
proceed with the upgrade.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 11/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
i. Since parameters cannot be read from device, you will have to set
the PSTX model number manually. Click Select and choose the
correct model number. Then click OK to start the firmware upgrade.
j. A message box will show up because of the parameters that cannot
be saved. Click Yes to continue with firmware upgrade.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 12/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
k. The firmware upgrade is now in progress. The upgrade takes up to
15 minutes.
l. The upgrade is now completed, click Finish to exit upgrade wizard.
m. Restore all modified parameters by setting each parameter to the
value stored before firmware upgrade, see section 1.2.2 Backup parameters.
n. Done, firmware update completed.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 13/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
2 How to upgrade PSE firmware
The PSE firmware can be found at ABB Library. It is only published
internally ABB, but sharing to customers is approved. To upgrade the PSE
softstarter with the firmware, the SoftstarterCare is required. Use the
hyperlinks below to download from the ABB library (only available for ABB
personnel - intranet).
• SoftstarterCare
It is also possible to find the PSE firmware and the SoftstarterCare under
Documents- >Software at ABB Library - PSE Softstarter.
2.1 Preparation
a. You need a USB cable for ABB SoftstarterCare - Service Engineer
Tool
• Type code: PSECA
• Order code: 1SFA897201R1001
b. Unzip and Install ABB SoftstarterCare - Service Engineer Tool on your
PC.
Note: Please make sure to install the correct version of the Visual C++ Redistributable for Visual Studio 2015 package prior to installation of Softstarter Care. No matter what type of Windows computer you have, please install the x86 version (32-bits) as Softstarter Care is a 32-bits application. It also applies to 64-bits computers. The file name of the redistributable package to download and install from microsoft.com is vc_redist.x86.exe.
2.2 Upgrade firmware
a. Ensure that the PSE softstarter is disconnected from operational
voltage and control supply voltage (100-250V). It only requires the
power from the USB.
b. Start SoftstarterCare and confirm that the softstarter is connected.
Windows Start->All programs->ABB-> ABB SoftstarterCare™ - Service Engineer Tool-> SoftstarterCare™ - Service Engineer Tool.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 14/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
c. Click on Firmware upgrade to start the firmware upgrade wizard.
d. Select the firmware (.cab) file and then click Next.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 15/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
e. The softstarter parameters are stored to a specified directory for
allowing user to restore parameters after upgrade.
Click Next to use the default directory and start the firmware
upgrade.
f. The firmware upgrade is now in progress. The upgrade takes up to 1
minute.
Technical Instruction Released
Softstarter Firmware Upgrade Instruction 2019- August- 27 16/16
FILE: 2CMT001197D0169 Softstarter Firmware Upgrade Instruction rev B03.docx We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
© ABB Group Processes Ltd; 2019
g. Message box asks whether you want to restore parameters or not.
Click Yes to restore parameters.
h. The upgrade is now completed. Click Finish.