53
Kukdong LSHF - NEK 606 2004
Marketing Office Tel:82-2-2140-3055 Fax:82-2-2140-3098Head Office Tel:82-43-530-2000 Fax:82-43-530-2144 Pusan Office Tel:82-51-817-0295 Fax:82-51-817-0297
Hig
h V
olta
ge F
lam
e Re
tard
ant C
able
Hig
h V
olta
ge F
lam
e&
Fir
e Re
sist
ant C
able
Low
Vol
tage
Flam
e Re
tard
ant
Cable
Low
Vol
tage
Fla
me
& F
ire
Resi
stan
t Cab
leTe
chni
cal i
nfor
mat
ion
ApplicationPower circuit below 1kV, Lighting circuits, Trace heating circuits.Fixed installation power, control & lighting in both explosion risk and safe areas, generalpurposes.Maximum operating conductor temperature 90
Standard AppliedDesign guideline : IEC 60092-353Material properties : IEC 60092-351 (Insulation, HF-EPR)
IEC 60092-359 (Sheath, SHF2)Flame retardant : IEC 60332-3-22, Cate. ‘A’Halogen free properties : IEC 60754-1Low smoke properties : IEC 61034-1/2Cold properties(option) : CSA C22.2 No. 03Sunlight resistance(option) : UL 1581Mud resistance(option) : NEK 606 (2004)
0.6/1kV SINGLE CORE, ARMORED POWER CABLE (CODE : 0.6/1kV RFOU[P1], RFOU[P1/P8])
Conductor
Nominal Min. Max.sectional No. of overall area wires dia.
mm2 EA mm
No.of core
EA
1
1.0 7 1.4
1.5 7 1.7
2.5 7 2.2
4 7 2.7
6 7 3.3
10 7 4.2
16 7 5.3
25 7 6.6
35 7 7.9
50 19 9.1
70 19 11.0
95 19 12.9
120 37 14.5
150 37 16.2
185 37 18.0
240 61 20.6
300 61 23.1
Cableweightapprox
kg/km
120
135
150
180
205
270
350
535
655
825
1080
1410
1685
2020
2455
3155
3865
Conductorresistance(20 )
/km
18.2
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.1000
0.0762
0.0607
Cableratingat 45
Amp.
18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601
Nominaloveralldia.
mm
8.4 0.4
8.9 0.4
9.3 0.4
9.9 0.4
10.4 0.4
11.6 0.5
12.6 0.5
15.1 0.6
16.3 0.7
18.2 0.7
20.3 0.8
22.8 0.9
24.4 1.0
26.6 1.1
29.0 1.2
32.7 1.3
35.9 1.4
Thicknessof outersheath
mm
1.0
1.1
1.1
1.1
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
Nominaldia. overbraid
mm
6.2
6.5
6.9
7.5
8.0
9.0
10.0
12.3
13.5
15.2
17.1
19.4
21.0
23.0
25.2
28.7
31.5
Dia. ofmetal wire forbraid
mm
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Nominaldia. over innercovering
mm
5.1
5.4
5.8
6.4
6.9
7.9
8.9
10.7
11.9
13.6
15.5
17.8
19.4
21.4
23.6
27.1
29.9
Thickness of inner covering
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
Thickness of insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
Construction
Conductor : Circular tinned stranded copper as per IEC60228 & 60228A, Class 2Insulation : Halogen Free Ethylene Propylene Rubber (HF-EPR)as per IEC 60092-351Inner covering : Halogen-free thermosetting compoundAmour : Copper wires braid as per IEC 60092-353Outer sheath : Flame retardant, oil, abrasion, chemical andsunlight resistant.- Code-P1 : Halogen-free thermosetting compound as per IEC60092-359, SHF2
- Code-P1/P8 : Halogen-free & Mud resistance thermosettingcompound as per IEC 60092-359, SHF Mud
Identification of color
Insulation1 : Grey
Outer sheath : BlackNote) Any other colors purchaser required
IEC 60332-3-22 : Flame retardant, Cate ‘A’IEC 60754-1 : Halogen free, 0.5%IEC 61034-1/2 : Smoke densityCSA C22.2 No.03 : Cold bend, 40
Cold impact, 35UL 1581 : Sunlight resistanceNEK 606 : Mud resistance
Marketing Office Tel:82-2-2140-3055 Fax:82-2-2140-3098Head Office Tel:82-43-530-2000 Fax:82-43-530-2144 Pusan Office Tel:82-51-817-0295 Fax:82-51-817-029754
Kukdong LSHF - NEK 606 2004
ApplicationPower circuit below 1kV, Lighting circuits, Trace heating circuits.Fixed installation power, control & lighting in both explosion risk and safe areas, generalpurposes.Maximum operating conductor temperature 90
Standard AppliedDesign guideline : IEC 60092-353Material properties : IEC 60092-351 (Insulation, HF-EPR)
IEC 60092-359 (Sheath, SHF2)Flame retardant : IEC 60332-3-22, Cate. ‘A’Halogen free properties : IEC 60754-1Low smoke properties : IEC 61034-1/2Cold properties(option) : CSA C22.2 No. 03Sunlight resistance(option) : UL 1581Mud resistance(option) : NEK 606 (2004)
0.6/1kV DOUBLE CORE, ARMORED POWER CABLE (CODE : 0.6/1kV RFOU[P1], RFOU[P1/P8])
Conductor
Nominal Min. Max.sectional No. of overall area wires dia.
mm2 EA mm
No.of core
EA
2
1.0 7 1.4
1.5 7 1.7
2.5 7 2.2
4 7 2.7
6 7 3.3
10 7 4.2
16 7 5.3
25 7 6.6
35 7 7.9
50 19 9.1
70 19 11.0
95 19 12.9
120 37 14.5
150 37 16.2
185 37 18.0
240 61 20.6
300 61 23.1
Cableweightapprox
kg/km
245
270
320
440
525
685
895
1295
1630
2085
2795
3780
4560
5500
6675
8605
10510
Conductorresistance(20 )
/km
18.2
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.1000
0.0762
0.0607
Cableratingat 45
Amp.
15
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511
Nominaloveralldia.
mm
12.3 0.5
12.9 0.5
13.7 0.5
15.6 0.6
16.8 0.7
18.8 0.8
21.0 0.8
25.0 1.0
27.6 1.1
31.2 1.2
35.8 1.4
41.2 1.6
44.8 1.8
49.2 2.0
53.8 2.2
61.0 2.4
67.0 2.7
Thicknessof outersheath
mm
1.2
1.2
1.2
1.3
1.4
1.4
1.5
1.7
1.8
1.9
2.1
2.3
2.4
2.6
2.7
3.0
3.2
Nominaldia. overbraid
mm
9.7
10.3
11.1
12.8
13.8
15.8
17.8
21.4
23.8
27.2
31.4
36.4
39.8
43.8
48.2
54.8
60.4
Dia. ofmetal wire forbraid
mm
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
Nominaldia. over innercovering
mm
8.6
9.2
10.0
11.2
12.2
14.2
16.2
19.8
22.2
25.6
29.8
34.4
37.8
41.8
46.2
52.8
58.4
Thickness of inner covering
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
Thickness of insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
Construction
Conductor : Circular tinned stranded copper as per IEC60228 & 60228A, Class 2Insulation : Halogen Free Ethylene Propylene Rubber (HF-EPR)as per IEC 60092-351Cabling (with filler)Inner covering : Halogen-free thermosetting compoundAmour : Copper wires braid(screen) as per IEC 60092-353Outer sheath : Flame retardant, oil, abrasion, chemical andsunlight resistant.- Code-P1 : Halogen-free thermosetting compound as per IEC60092-359, SHF2
- Code-P1/P8 : Halogen-free & Mud resistance thermosettingcompound as per IEC 60092-359, SHF Mud
Identification of color
Insulation2 : Grey, Black
Outer sheath : BlackNote) Any other colors purchaser required
IEC 60332-3-22 : Flame retardant, Cate ‘A’IEC 60754-1 : Halogen free, 0.5%IEC 61034-1/2 : Smoke densityCSA C22.2 No.03 : Cold bend, 40
Cold impact, 35UL 1581 : Sunlight resistanceNEK 606 : Mud resistance
RFCU
= with galvanized steel wire braid
Marketing Office Tel:82-2-2140-3055 Fax:82-2-2140-3098Head Office Tel:82-43-530-2000 Fax:82-43-530-2144 Pusan Office Tel:82-51-817-0295 Fax:82-51-817-029756
Kukdong LSHF - NEK 606 2004
ApplicationPower circuit below 1kV, Lighting circuits, Trace heating circuits.Fixed installation power, control & lighting in both explosion risk and safe areas, generalpurposes.Maximum operating conductor temperature 90
Standard AppliedDesign guideline : IEC 60092-353Material properties : IEC 60092-351 (Insulation, HF-EPR)
IEC 60092-359 (Sheath, SHF2)Flame retardant : IEC 60332-3-22, Cate. ‘A’Halogen free properties : IEC 60754-1Low smoke properties : IEC 61034-1/2Cold properties(option) : CSA C22.2 No. 03Sunlight resistance(option) : UL 1581Mud resistance(option) : NEK 606 (2004)
0.6/1kV THREE CORE, ARMORED POWER CABLE (CODE : 0.6/1kV RFOU[P1], RFOU[P1/P8])
Conductor
Nominal Min. Max.sectional No. of overall area wires dia.
mm2 EA mm
No.of core
EA
3
1.0 7 1.4
1.5 7 1.7
2.5 7 2.2
4 7 2.7
6 7 3.3
10 7 4.2
16 7 5.3
25 7 6.6
35 7 7.9
50 19 9.1
70 19 11.0
95 19 12.9
120 37 14.5
150 37 16.2
185 37 18.0
240 61 20.6
300 61 23.1
Cableweightapprox
kg/km
280
320
420
510
610
830
1100
1560
2000
2620
3580
4700
5750
6960
8560
10940
13490
Conductorresistance(20 )
/km
18.2
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.1000
0.0762
0.0607
Cableratingat 45
Amp.
12
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421
Nominaloveralldia.
mm
12.7 0.5
13.4 0.5
15.0 0.6
16.2 0.6
17.5 0.7
19.9 0.8
22.2 0.9
26.1 1.0
29.3 1.2
33.5 1.3
38.4 1.5
43.5 1.7
47.7 1.9
52.4 2.1
57.9 2.3
65.0 2.6
71.9 2.9
Thicknessof outersheath
mm
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.7
1.8
2.0
2.2
2.3
2.5
2.7
2.9
3.1
3.4
Nominaldia. overbraid
mm
10.2
10.9
12.3
13.5
14.6
16.8
18.9
22.8
25.4
29.5
34.0
38.9
42.6
46.9
52.0
58.7
64.9
Dia. ofmetal wire forbraid
mm
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Nominaldia. over innercovering
mm
9.1
9.8
10.7
11.9
13.0
15.2
17.3
21.0
24.0
27.8
31.9
36.8
40.6
44.9
50.0
56.7
63.0
Thickness of inner covering
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.8
Thickness of insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
Construction
Conductor : Circular tinned stranded copper as per IEC60228 & 60228A, Class 2Insulation : Halogen Free Ethylene Propylene Rubber (HF-EPR)as per IEC 60092-351Cabling (with filler)Inner covering : Halogen-free thermosetting compoundAmour : Copper wires braid(screen) as per IEC 60092-353Outer sheath : Flame retardant, oil, abrasion, chemical andsunlight resistant.- Code-P1 : Halogen-free thermosetting compound as per IEC60092-359, SHF2
- Code-P1/P8 : Halogen-free & Mud resistance thermosettingcompound as per IEC 60092-359, SHF Mud
Identification of color
Insulation3 : Grey, Black, Red 3phase3G : Grey, Black, Green/Yellow stripe
1phase, neutral & protectiveearth
Outer sheath : BlackNote) Any other colors purchaser required
IEC 60332-3-22 : Flame retardant, Cate ‘A’IEC 60754-1 : Halogen free, 0.5%IEC 61034-1/2 : Smoke densityCSA C22.2 No.03 : Cold bend, 40
Cold impact, 35UL 1581 : Sunlight resistanceNEK 606 : Mud resistance
RFCU
= with galvanized steel wire braid
89
Kukdong LSHF - NEK 606 2004
Marketing Office Tel:82-2-2140-3055 Fax:82-2-2140-3098Head Office Tel:82-43-530-2000 Fax:82-43-530-2144 Pusan Office Tel:82-51-817-0295 Fax:82-51-817-0297
Hig
h V
olta
ge F
lam
e Re
tard
ant C
able
Hig
h V
olta
ge F
lam
e&
Fire
Res
ista
nt C
able
Low
Vol
tage
Fla
me
Reta
rdan
t Cab
leLo
w V
olta
ge F
lam
e &
Fire
Res
ista
nt C
able
Tech
nica
l inf
orm
atio
n
ApplicationPower circuit below 1kV, Motor Power circuit for PWM AC Drives.Fixed installation power in both explosion risk and safe areas, general purpose.Maximum operating conductor temperature 90
Standard AppliedDesign guideline : IEC 60092-353Material properties : IEC 60092-351 (Insulation, HF-EPR)
IEC 60092-359 (Sheath, SHF2)Flame retardant : IEC 60332-3-22, Cate. ‘A’Halogen free properties : IEC 60754-1Low smoke properties : IEC 61034-1/2Cold properties(option) : CSA C22.2 No. 03Sunlight resistance(option) : UL 1581Mud resistance(option) : NEK 606 (2004)
0.6/1kV THREE CORE+THREE EARTH, ARMORED POWER CABLE (Code : 0.6/1kV RFOU-EMC, RFOU-EMC ‘MR’)
Construction
Conductor : Circular tinned stranded copper as per IEC 60228& 60228A, Class 2Insulation : Halogen Free Ethylene Propylene Rubber (HF-EPR) asper IEC 60092-351Cabling (with filler)Inner covering : Halogen-free thermosetting compoundAmour(screen) : Cu/PS tape & Copper wire braid combination100% shield screen.Outer sheath : Flame retardant, oil, abrasion, chemical andsunlight resistant.- Halogen-free thermosetting compound as per IEC 60092-359,SHF2
- ’MR’ : Halogen-free & Mud resistance thermosettingcompound as per IEC 60092-359, SHF Mud
Identification of color
Insulation3 : Grey, Black, RedEarth : Green or Green/Yellow stripe
Outer sheath : BlackNote) Any other colors purchaser required
Technical specification
VoltagesRated AC and DC voltage Uo/U(Um) ; 0.6/1(1.2)kVMax. permissible periodic peak voltage : 2kVAC test voltage : 5kVeff (Standard test voltage 3.5kV/5min)Min. bending radius : 6 cable outside diameterMax. permissible tensile load : 50N/mm2(sum of cross-section of all conductors in mm2)Permissible operation with conductor earth fault in non-earthed networks ; max. eight hours, but notmore than 125hours within a period of one year.
IEC 60332-3-22 : Flame retardant, Cate ‘A’IEC 60754-1 : Halogen free, 0.5%IEC 61034-1/2 : Smoke densityCSA C22.2 No.03 : Cold bend, 40
Cold impact, 35UL 1581 : Sunlight resistanceNEK 606 : Mud resistanceEMC : Electromagnetic Compatibility
Conductor
Nominal Min. Max.sectional No. of overall area wires dia.
mm2 EA mm
No.of core
EA
3+3E
25 7 6.66 7 3.3
35 7 7.910 7 4.2
50 19 9.110 7 4.2
70 19 11.016 7 5.3
95 19 12.925 7 6.6
120 37 14.525 7 6.6
150 37 16.235 7 7.9
185 37 18.035 7 7.9
240 61 20.650 19 9.1
300 61 23.150 19 9.1
Cableweightapprox
kg/km
1775
2375
2860
3950
5390
6330
7780
9315
12005
14395
Conductorresistance(20 )
/km
0.7343.11
0.5291.84
0.3911.84
0.2701.16
0.1950.734
0.1540.734
0.1260.529
0.10000.529
0.07620.391
0.06070.391
Cableratingat 45
Amp.
89
110
137
169
205
237
272
311
365
421
Nominaloveralldia.
mm
28.6 1.1
32.7 1.3
33.9 1.4
38.8 1.6
44.3 1.8
48.0 1.9
52.7 2.1
58.2 2.3
65.5 2.6
72.1 2.9
Thicknessof outersheath
mm
1.8
1.9
2.0
2.2
2.4
2.5
2.7
2.9
3.2
3.4
Nominaldia. overbraid
mm
24.8
28.7
29.7
34.2
39.3
42.8
47.1
52.2
58.9
65.1
Dia. ofmetal wire forbraid
mm
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Nominaldia. over innercovering
mm
23.2
27.1
28.1
32.2
37.3
40.8
45.1
50.2
56.9
63.1
Thickness of inner covering
mm
1.0
1.2
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8
Thickness of insulation
mm
1.21.0
1.21.0
1.41.0
1.41.0
1.61.2
1.61.2
1.81.2
2.01.2
2.21.4
2.41.4