Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control
Jim FeatherExxonMobil Research & Engineering
OLI 23rd User ConferenceOctober 5-6, 2005
2
Presentation Outline
• Challenges with corrosion prediction• Application Overview• Example Applications• Looking Ahead
3
Refinery Corrosion Analysis
• Corrosion control applications often focus on a particular section of a process unit
• Complex modeling tools aren’t easily applied to routine operating envelope management
• Chemistry of corrosion environment remains complex
• Corrosion rates at complex conditions or across a process may not be easily predictable
4
Analyzers Bring Modeling Tools to the Corrosion Engineer
• OLI Analyzers are facilitating evaluations of conditions important to aqueous corrosion– Aqueous phase dew point– Aqueous phase condensation profile– Application of corrosion control methods
• Changes in operating conditions readily evaluated for their impact on chemistry
• Effectiveness of corrosion control measures more readily evaluated
5
General Application of Analyzers to Corrosion Prediction• Tools used in several ways to improve corrosion
predictions– Model chemistry and use other tools for
corrosion rate predictions– Model chemistry and compare with operating
envelope constraints– Direct estimation of corrosion rate with Corrosion
Analyzer• Assess the impact of changes or mitigation
measures in the process on corrosion– Water wash & chemical treatment programs– Validation of 3rd party corrosion inhibitor
programs
6
Example Refinery Applications
• Common applications of interest– Crude distillation unit overhead – Acid
condensate corrosion, water wash application– FCCU overhead systems – Sour water corrosion,
Carbonate stress corrosion cracking, water wash application
– Coker overhead systems – Sour water corrosion– Hydrotreater reactor effluent systems – Sour
water corrosion, water wash application• Estimation of corrosivity of environments without
readily available corrosion data
7
Application to Crude Distillation Unit Overhead
Naphtha
CRUDEFEED
DESALTER
Acidic WaterCondensate
INHIBITOR
NEUTRALIZER
Steam Reduced Crude
Kerosene
Light Gas Oil
Heavy Gas Oil
Acidic WaterCondensate
8
Conditions of Untreated Overhead
9
More Corrosive Conditions at Dewpoint
10
Est. Corrosion through Condensation Range
11
Impact of Neutralizer Addition in CDU Overhead
12
Effect of Neutralizer During Condensation
13
Controlling Corrosion in FCCU Overheads
• Carbonate stress corrosion cracking in non-stress relieved carbon steel piping is a growing problem – May be associated with operations which
increase NH3 & CO2 in overhead water while unit feed sulfur is being reduced by hydroprocessing
– Greatest likelihood of cracking occurs:• pH < 9.0 and CO3 > 100 ppm
• pH between 8.0 and 9.0 and CO3 > 400 ppm
– Direct measurement of carbonate is not straightforward
• General corrosion control also an important issue, often managed by water wash
-2
-2
14
Carbonate SCC
15
Conditions promoting SCC in FCCU’spH
Log CO3, ppm
SCC Not Likely
SCC Possible
SCC Likely
From NACE C/90 Paper 206, Kemetz & Truax
16
Analyzer Used to Evaluate FCCU OH
• Analyzer used to model changes in operations with other model as input
• Outputs pH & carbonate ion concentration to support cracking likelihood assessment
• Benefit of corrosion & cracking control mitigation measures evaluated– General corrosion – balance corrosion vs
operational issues with excess water– Model impact of measures taken to reduce
tendency for cracking• Dilution • pH adjustment
17
Looking Ahead
• Prediction of salt deposition a needed capability– Corrosive NH4Cl salt forms in refinery
processes• Crude distillation• Hydroprocessing• FCCU’s & Cokers
– Amine chloride salt important in neutralizer applications
– Corrosion predictions “nice to have” but modeling of deposition more important