onlineUPS COMPACT
AP160N
•LOCALAREANETWORKS(LAN)
•SERVERS
•DATACENTERS
•INTERNETCENTERS(ISP/ASP/POP)
•INDUSTRIALPLCS
•EMERGENCYDEVICES(LIGHT,ALARM)
•ELECTROMEDICALDEVICES
•TELECOMMUNICATIONDEVICES
•INDUSTRIALAPPLICATION
Rack–towerconvertible1-10kVA
COMMONFEATURES:
GTEC is proud to introduce the latest Rack-Tower covertibleAP160NUPS,which can deliver clean, safe, and regulatedpowersupplytoprotectyourmissioncriticalequipment,soastosafeguardyourvaluabledatafromanyabnormalpowerdisturbances,suchas:powersurges,powerdipsorpowerblackout.
AP160Nisavailablewith1kVA;2kVA;3kVA;6kVAand10kVArange,itscompactdesignallowsAP160Ntoadaptwithinalimitedrackspacebutdemandedforhighpowersupply.
AP160NisfullyDSPcontrolleddesignedforhighestpowerdensity;reliabilityandpoweravailabilitysuitableallITloadsforServersandinDataCenter.
AP160N series
•ExcellentReliability•HighPowerDensity•FlexibleSettings•CompactSolution•LowerPowerConsumption•LongruntimeModel•Rack-TowerConvertible
COMMONFEATURES
ExCELLENTRELiAbiLiTy•DSPtechnologyfullycontrolled•RotarysegmentLCDdisplaywitheasyaccess•Selfmonitoringandfaultdiagnosis
HigHPOwERDENSiTy•Wideinputvoltagerange•0,9loadPFincreasethepoweravailability• Inputpowerfactorcorrectionforthelowestcurrentdistortion
FLExibLESETTiNgS•SelectableconfigurationviaLCD:online, eco-modeandfrequencyconvertermode(CVCF)•EPOconnectorforemergencypoweroff
COMPACTSOLUTiON•Higher power performance in slim height for 19’’rackspace
• Internalbatteriesincluded,witheasyreplacement•Standardbatteryconnectorforadditionalbackuptime
LOwERPOwERCONSUMPTiON•Veryhighefficiency•Ecomodeoperationavailableforefficiencyupto97%• Lowerheatingdissipation
LONgRUNTiMEMODEL•Dedicatedsolutionavailablewithsuperchargerforlongautonomy
•Using external batteries with large capacity withdedicatedbatterypack
1kVAto3kVA
FLExibLESETTiNgS• Loadsegments(outlet)control
• Standardsingledrycontactport
programmable
COMPACTSOLUTiON• Slim2Uheightfor19”rackspace
LOwERPOwERAUTO-CONSUMPTiON• Highefficiencyupto90%
• UPSSTATUS• bATTERyCAPACiTy• LOADLEVEL• iNPUT/OUTPUTVOLTAgE• iNPUT/OUTPUTFREqUENCy• FAULT/wARNiNgS• SETTiNgMODE
AP160N
MENU:
1 2 4 753 6 8
1
1
1
2
2
2
4
4
4
7
7
7
5
5
5
3
3
3
6
6
6
8
8
8
Description
1 ACOutput
2 EPO/Dry-InCommunication
3 Dry-OutCommunication
4 IntelligentSlot
5 USBSlot
6 RS232Port
7 ACInput
8 EarthTerminal
AP160N, 1K/1KS/2K rear panel
AP160N, 2KS rear panel
AP160N, 3K rear panel
AP160N, 3KS rear panel
AP160N6kVAto10kVA
FLExibLESETTiNgS• Redundantparallel1+1configuration
•Optional hot swappable PDU with
powersegmentoutletsandmechanical
maintenancebypassswitch
COMPACTSOLUTiON•3U package for the 6kVA version and
5Upackageforthe10kVA,withinternal
batteriesincluded
• Dualinputs,withseparatedbypass
LOwERPOwERAUTO-CONSUMPTiON• Efficiencygreaterthan93%
IntelligentSlot
ParallelPort(optional)
RS232 USb ExtBatteryConnector
ACOutput Terminals MaintenanceBypass
EPO
• UPSSTATUS• bATTERyCAPACiTy• LOADLEVEL• iNPUT/OUTPUTVOLTAgE
• iNPUT/OUTPUTFREqUENCy• FAULT/wARNiNgS• SETTiNgMODE
AP16N -10KPDU
MENU:
CommunicationandPowerManagementSolutionsET
HER
NET
NET
WO
RK
POWER SUPPLY
WinPowerCDispackedwithUPS,andcanalsobedownloadedfromtheinternet.Ithasthefunctiontoremote
monitorandcontrolUPS,warningnotifications throughbroadcastandmobilephone,multi-shutdownPCs,and
scheduleUPSself-test.Thisuniquesoftwareprovidescompletepowerprotectionforcomputersystemduringpo-
werfailure.ThesoftwaresupportslotsofO/SincludingWindowsfamily,Linux,SunSolaris7/8/9,FreeBSD,IBMAix
4.3x,5.1x,andHP-UX11.x.Morethanthat,toofferincreasedbenefitsforourcustomers,wehavealsoreleased
USBversionMACversionontheinternet.
•PowerflowdisplayformonitoringUPSstatus•Scheduledsystemshutdown/restart•ScheduledUPStest•WarningnotificationviaE-mail/Pager•WarningnotificationviaBroadcast•Passwordsecurityprotection•RemoteMonitor/ControlviaLAN
•Multi-languageversions:English,German,French,Italian,Spanish,PortugueseandChinese•SelectableUserInterface(Background)•UPSParametersetting•Recordlogsforanalysis•SNMPNetworkcardallowsmanagementofUPSacrossLANusinganyofthemainnetworkcommunicationprotocols–TCP/IPandnetworkinterfaceviaSNMP.
INPUT SWITCHBOARD
OUTPUT SWITCHBOARD
LOAD LOAD LOAD LOAD
AP160N 6kVA to 10kVA UPS with optional parallel kit fittedin parallel configuration, can meet most demanding powerrequirement.Increasepoweravailabilityandflexibility.
Parallel Redundancy feature provides economic power solutionforsystemintegration.Furthermore,parallelredundancyfeatureequallysharestheloadtomaximizeUPSperformance,andmoresecureUPScontinuousoperation.
RELAYCARD/AS400SNMPCARD MODBUSINTERFACE
INPUT SWITCHBOARD
OUTPUT SWITCHBOARD
LOAD LOAD LOAD LOAD
iNTERFACEOPTiON:
TECHNICAL SPECIFICATIONSModel AP160N 1K 1KS* 2K 2KS* 3K 3KS* 6K 6KS* 10K 10KS*Power Rating 1000VA/900W 2000VA/1800W 3000VA/2700W 6000VA/5400W 10000VA/9000W
INPUTRated Voltage 220Vac / 230Vac / 240VacVoltage Tolerance 120 ÷ 276 Vac
Voltage Range120Vac-276Vac (± 3 %) at 50% load148Vac-276Vac (± 3 %) at 75% load176Vac-276Vac (± 3 %) at 100% load
120Vac-276Vac (± 3 %) at 50% load
176Vac-276Vac (± 3 %) at 100% load
AC Input Connector IEC 320, C14 10A/ 250V socket
IEC 320, C20 16A/ 250V
socket
Terminal block Connectors
Frequency Range 45Hz÷55Hz / 54Hz÷66HzTHDi% < 5% at full loadPower Factor > 0.99 (I/P220Vac, full RCD load)
OUTPUTRated Voltage 208Vac** / 220Vac / 230Vac / 240VacVoltage Regulation ± 1%Rated Frequency AC mode 50/60 ± 0,2%Crest Factor 3:1Harmonic Distortion ≤ 2% THD ( Linear Load)Output Waveform Pure SinewavePower factor 0,9
Output Connection 8 x IEC 320, C13 10A 250V recepticles
8 x IEC 320, C13 10A/ 250V and 1x IEC 320, C19 16A/ 250V
recepticles
KS Version: 2 x IEC 320, C13 10A &
2 x IEC 320, C19 16A 250V recepticles &
output terminal
KS Version: 4 x IEC 320, C13 10A &
2 x IEC 320, C19 16A 250V recepticles &
output terminalBATTERy
Type Sealed lead acid battery, maintenance freeRating 12V/7.2Ah 36Vdc
Depending on the
capacity of external batteries
12V/9AH 48Vdc Depending
on the capacity
of external batteries
12V/9AH 72Vdc Depending
on the capacity
of external batteries
12V/5AH 180Vdc Depending
on the capacity
of external batteries
12V/9AH 240Vdc Depending
on the capacity
of external batteries
Numbers of Batteries 3 4 6 15 20
Backup Time (typical load) > 6 mins > 6 mins > 6 mins > 5 mins > 7 mins
Recharge Time 3 hours to 90%
3 hours to 90%
3 hours to 90%
3 hours to 90%
3 hours to 90%
GENERAL CHARACTERISTICSTransfer time 0ms
Dual Input to Bypass N/A yES
Parallel configuration N/A yES as optionalEfficiency (online mode) > 87% > 89% > 90% > 93%Dimensions LxDxH (mm) 438x435x2U 438x608x3U 438x560x3U*** 438x560x5U***Weight UPS case (kg) 15.3 9.1 30.5 12.3 33.2 13.5 46.5 18.0 82.5 32.5Operating Temperature 0-40° CHumidity 0-95% (non-condensing)Noise Level (@ 1m) <45dB <50dB <55dB
Interface standard via Smart USB WinPower Software supports: Windows 95/98/NT/2000/XP/ME, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC
Interface for Intelligent Slot SNMP /AS400 Card / Modbus all optional
Compliance IEC 61000-4, IEC 62040-1, IEC 62040-2, IEC 62040-3, IEC 60950-1,IEC 62040-1, ETS 300019-2-2
AP160N
* ks version are provided with battery extra charger** Derate to 90% with 208Vac output voltage*** Dimension is depth of casing, excluding cable gland & PDUNote: product specifications are subject to change without further notice.
G-Tec Companies are also present worldwide with Business Partners in several countries.
G-Tec Asia Pacific Pte Ltd
60 Kaki Bukit Place, #03-05, Eunos Techpark II, Singapore 415979
Tel. +65 6555.5014 - Fax +65 6555.4105
G-Tec Europe srl
Strada Marosticana, 81/13 - 36031 Povolaro (VI), Italia
Tel. +39 0444.361321 - Fax +39 0444.365191
www.gtec-power.com
Rev.31.12.2012
Top Related