Download - Ammonia Flow Control Unit - Integrated Flow Solutions · Complete System Designed to API RP 550 Standard Features Heavy Duty Single or Multistage Centrifugal Air Blowers - Arrangement

Transcript
Page 1: Ammonia Flow Control Unit - Integrated Flow Solutions · Complete System Designed to API RP 550 Standard Features Heavy Duty Single or Multistage Centrifugal Air Blowers - Arrangement

Industries

BenefitsSingle Source AccountabilityPre-Packaged Modular Design Costs LessThan Component Based Site-Built SystemsReducing Overall Project CostMinimizes Field Erection Time -Shorter Overall Project Delivery ScheduleComplete System Function TestingPrior To Shipment24/7 Customer Service

Industry StandardsPiping Designed to ANSI B31.1/ANSI B31.3Pipe Fabrication to ASME Section IXStructural Steel Assembly Designed to AWS D1.1Complete System Designed to API RP 550

Standard FeaturesHeavy Duty Single or Multistage CentrifugalAir Blowers - Arrangement 4, 7 & 8INTEGRAHEATTM Electric Process Air Heating withFull Thyrister Power Controls, Motor Interlock andRedundant Safety Shutdown SystemLocally Mounted PLC Based ControlSystem Per NEC & NFPAVaporization Using Co-Current Mixing orCounter Flow Contact TechnologyComplete Factory Function Test

AFCU-100.0

Integrated Flow Solutions Ammonia Flow Control Units aredesigned to control the flow of ammonia from the AmmoniaStorage/Forwarding System into an air or flue gas stream. Theair is typically pressurized and heated with an electric processheater or low pressure steam. The hot flue gas is availablefrom the gas turbine exhaust. The hot air or flue gas vaporizesthe ammonia prior to injection into the Ammonia InjectionGrid (AIG).

Ammonia FlowControl Unit

Process ParametersVaporized Ammonia - Up to 4,000 #/hrExhaust Temperatures - Up to 800oFDischarge Pressures - Up to 6 psig

Utility Requirements (Cold-AFCU)Heat Source: INTEGRAHEATTM Electric ProcessAir Heater

Power Requirement: 1KW - 1500KW/3 Phase/60 Hertz

ORHeat Source: Steam Heat Exchanger

Total Duty - Up to 12,500 MM BTU/HRBlower Motors - Up to 300 HP/3 Phase/460 VoltInstrument Air

Utility Requirements (Hot-AFCU)Heat Source: Hot Flue GasBlower Motors: Up to 300 HP/3 Phase/460 VoltInstrument Air

Optional FeaturesComplete Factory Performance TestUL or CSA Listed Control Heater& Control Panel AssemblyClass 1, Div. 2 Hazardous LocationsCompliance with Plant/Engineering Specifications

Additional Services“Aspen Plus” Process Simulation Software UsedTo Guarantee Process ConditionsInstallation/Training/Start-Up SupervisionExtended WarrantyNationwide Service Network

EMISSIONSGENERALPOWER

www.IFSolutions.com

INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068

www.IFSolutions.com

Page 2: Ammonia Flow Control Unit - Integrated Flow Solutions · Complete System Designed to API RP 550 Standard Features Heavy Duty Single or Multistage Centrifugal Air Blowers - Arrangement

INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068 2004 IFS These materials contain proprietary information and may not be reproduced without prior written permission from Integrated Flow Solutions.

AMMONIA FLOW - LENGTH - X WIDTH - Y HEIGHT - Z WEIGHT - LBS.#/HR

100 15’ 8’ 10’ 10,000500 22’ 10’ 10’ 15,000900 30’ 12’ 10’ 20,000

Ammonia Flow Control Unit

BLOWER B

SKID LIMITS

BLOWER A

M

M

PDIT

TT

PIT

PIT

FE

FT

HEATER

MIXER/VAPORIZERTT

TETE

TT

AMMONIA

TE

S

AMMONIA FLOW# / HR

AMMONIA INLET

AIR SUPPLYINSTRUMENT

SKID LIMITS

PITFIT

FE

ELEVATION

CONTROLPANEL

OV

ER

ALL

WID

TH

OVERALL LENGTH

PLAN

CONTROLPANEL

X

Y

1'-3 5/16"1'-3 5/16"

AP

PR

OX

. OV

ER

ALL

HE

IGH

T

Z

www.IFSolutions.com