Amazon VRF Products Overview
2
Product Lineup
3
Product LineupOffers Overview
T1 Mini VRF Outdoor T1/T3 Modular VRF Outdoor
Broad Indoor Offering
Note: The capacity mentioned in following pages is basically for cooling
Side Discharge Mini VRF Outdoor Units Dual Frequency 50/60Hz
DC Inverter Rotary Compressor
BLDC Fan ( BrushLess DC motor )
4
VProduct LineupT1 Mini VRF Outdoor Units
10kW
15/18kW
Note: 1hp is 2.8kW, 1TR is 3.52kW, and 1kW is 3.41kBtu/h
*: EER is W/W
Model NameNominalCapacity
kW
NominalCapacity
[TR]
CoolingEER/Heating COP
Power SupplyMax.
IndoorUnits
YV2VYH010KAR-D-X 10 3 3.14/4.39 220-230V/1Ph/50-60Hz 4YV2VYH015KAR-D-X 15 4 3.53/4.02 220-230V/1Ph/50-60Hz 8YV2VYH015KAS-D-X 15 4 3.17/4.16 380-400V/3Ph/50-60Hz 8YV2VYH018KAS-D-X 18 5 2.94/3.52 380-400V/3Ph/50-60Hz 9
Top Discharge Modular VRF Outdoor Units Dual Frequency 50/60Hz - 380V, 60Hz - 230V
DC Inverter Scroll Compressor & BLDC Fan
5 Basic Modular Units: 8hp, 10hp, 12hp, 14hp, 16hp
Free Combination Up to 48hp with incremental 2hp, max.
Indoor units up to 64
5
VProduct LineupT1 Modular VRF Outdoor Units
8/10hp
12/14/16hp
Note: 1hp is 2.8kW, 1TR is 3.52kW, and 1kW is 3.41kBtu/h*: EER/COP is W/W
Model NameNominalCapacity
hp
NominalCapacity
NominalCapacity
[TR]
CoolingEER/Heating COP
IEERBtu/W.h
Power SupplyMax.
IndoorUnits
YV2VYH022KAS-D-X 8 22.8kW 6 4.12/4.31 19.77 380-400V/3Ph/50-60Hz 13YV2VYH028KAS-D-X 10 28.9kW 8 3.97/4.12 18.91 380-400V/3Ph/50-60Hz 16YV2VYH033KAS-D-X 12 34.8kW 10 3.54/3.71 19.98 380-400V/3Ph/50-60Hz 19YV2VYH040KAS-D-X 14 41.5kW 11 3.70/3.95 19.37 380-400V/3Ph/50-60Hz 23YV2VYH045KAS-D-X 16 46.4kW 13 3.49/3.87 18.79 380-400V/3Ph/50-60Hz 26YV2VYH077BAH-D-X 8 81kBtu/h 6 4.21/4.40 20.15 220-230V/3Ph/60Hz 13YV2VYH096BAH-D-X 10 100kBtu/h 8 3.48/3.77 18.85 220-230V/3Ph/60Hz 16YV2VYH114BAH-D-X 12 120kBtu/h 10 3.48/3.87 19.61 220-230V/3Ph/60Hz 19YV2VYH137BAH-D-X 14 142kBtu/h 11 3.45/3.76 18.98 220-230V/3Ph/60Hz 23YV2VYH154BAH-D-X 16 153kBtu/h 13 3.22/3.53 18.33 220-230V/3Ph/60Hz 26
Top Discharge Modular VRF Outdoor Units Dual Frequency 50/60Hz
DC Inverter Scroll Compressor & BLDC Fan
3 Basic Modular Units: 8hp, 10hp, 12hp
Free Combination Up to 36hp with incremental 2hp, max.
Indoor units up to 36
High Ambient Operation Up to 52 ℃
6
VProduct LineupT3 Modular VRF Outdoor Units
8hp
10/12hp
Note: 1hp is 2.8kW, 1TR is 3.52kW, and 1kW is 3.41kBtu/h
*: EER/COP is W/W
Model NameNominalCapacity
hp
NominalCapacity
kW
NominalCapacity
[TR]
CoolingEER/Heating COP
IEERBtu/W.h
Power SupplyMax.
IndoorUnits
YV2VYH022KAS-D-X 8 23.2 7 3.58/4.33 20.50 380-400V/3Ph/50-60Hz 10YV2VYH028KAS-D-X 10 28.6 8 3.70/4.38 19.70 380-400V/3Ph/50-60Hz 13YV2VYH033KAS-D-X 12 35.2 10 3.76/4.28 19.76 380-400V/3Ph/50-60Hz 16
7
VProduct LineupIndoor Units – Ductless Type
220-230V/1Ph/50-60Hz Fit for All Outdoor Units
8
VProduct LineupIndoor Units – Ducted Type
220-230V/1Ph/50-60Hz Fit for All Outdoor Units
Note: HRV has air flow as its capacity
Capacity kBtu/h 7.5 9.5 12.3 15.3 19.1 24.2 27.3 30.7 38.2 47.7 77.1 95.5
Capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 22.6 28.0
Low Static PressureSlim Duct 185mm
(0/20Pa)
Low Static PressureDuct (0/20Pa)
Medium StaticPressure Duct
(50/96Pa)
Medium StaticPressure Duct
(80/120Pa)
Heat RecoveryVentilator
(CMH/CFM)
150/88
260/153
800/471
1000/588
Product Family
High Static PressureDuct (100-196Pa)
Fresh Air Unit
9
Broad Indoor Offering
Global Exclusive Front
Stylish Design & LED Display
Built in EEV & Easy to Installation
Without Built-in Drain Pump & Not Available for External Drain Pump
Vitamin C and ESF
Filter Optional
6 Models Ranging from 2.2kW to 7.1kW
10
VIndoor FeaturesHigh Wall
2.2/2.8/3.6/.4.5kW
5.6/7.1kW
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YVHVXH022WAR--FX 2.2 8 220-230V/1Ph/50-60Hz 938*265*187YVHVXH028WAR--FX 2.8 10 220-230V/1Ph/50-60Hz 938*265*187YVHVXH036WAR--FX 3.6 12 220-230V/1Ph/50-60Hz 938*265*187YVHVXH045WAR--FX 4.5 15 220-230V/1Ph/50-60Hz 938*265*187YVHVXH056WAR--FX 5.6 19 220-230V/1Ph/50-60Hz 1046*299*239YVHVXH071WAR--FX 7.1 24 220-230V/1Ph/50-60Hz 1046*299*239
Compact Design
280mm Ultra Thin Body
Two Way Air Flow
Quite Operation
Built in High Head Drain Pump
4 Models Ranging from 2.8kW to 5.6kW
11
VIndoor FeaturesTwo Way Cassette
2.8/3.6/.4.5/5.6kW
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
Panel Dimension(MM)
W*H*D
YV8VXH028WAR--GX 2.8 10 220-230V/1Ph/50-60Hz 817*280*620 1055*80*680YV8VXH036WAR--GX 3.6 12 220-230V/1Ph/50-60Hz 817*280*620 1055*80*680YV8VXH045WAR--GX 4.5 15 220-230V/1Ph/50-60Hz 817*280*620 1055*80*680YV8VXH056WAR--GX 5.6 19 220-230V/1Ph/50-60Hz 817*280*620 1055*80*680
Compact Design, 570mm*570mm Installation Size
Quite Operation
Built in High Head Drain Pump
5~10% Fresh Air Inlet Except for 5.6/7.1/8.0 kW
Branch Outlet Except for 2.8/3.6/4.5kW
9 Models Ranging from 2.8kW to 14kW
12
VIndoor FeaturesFour Way Cassette
2.8/3.6/.4.5kW(Compact)
5.6/7.1/8.0kW
9.0/12/14kW
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
Panel Dimension(MM)
W*H*D
YVKVXH028WAR--GX 2.8 10 220-230V/1Ph/50-60Hz 570*260*570 700*60*700YVKVXH036WAR--GX 3.6 12 220-230V/1Ph/50-60Hz 570*260*570 700*60*700YVKVXH045WAR--GX 4.5 15 220-230V/1Ph/50-60Hz 570*260*570 700*60*700YVKVXH056WAR--GX 5.6 19 220-230V/1Ph/50-60Hz 840*240*840 950*80*950YVKVXH071WAR--GX 7.1 24 220-230V/1Ph/50-60Hz 840*240*840 950*80*950YVKVXH080WAR--GX 8 27 220-230V/1Ph/50-60Hz 840*240*840 950*80*950YVKVXH090WAR--GX 9 31 220-230V/1Ph/50-60Hz 840*295*840 950*80*950YVKVXH112WAR--GX 12 38 220-230V/1Ph/50-60Hz 840*295*840 950*80*950YVKVXH140WAR--GX 14 48 220-230V/1Ph/50-60Hz 840*295*840 950*80*950
Compact Design & Small Space Occupation
Quite Operation
Air Discharge through Top(Cooling) or Bottom(Heating)
Without Built-in Drain Pump & Not Available for External Drain Pump
4 Models Ranging from 2.2kW to 5.6kW
13
VIndoor FeaturesConsole
2.2/2.8/3.6/5.6kWModel Name
NominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YV5VXH022WAR--FX 2.2 8 220-230V/1Ph/50-60Hz 720*640*255YV5VXH028WAR--FX 2.8 10 220-230V/1Ph/50-60Hz 720*640*255YV5VXH036WAR--FX 3.6 12 220-230V/1Ph/50-60Hz 720*640*255YV5VXH056WAR--FX 5.6 19 220-230V/1Ph/50-60Hz 720*640*255
Compact Design
Quite Operation
Wide Range Angle Air Flow
ESF Filter Optional
9 Models Ranging from 2.8kW to 14kW
14
VIndoor FeaturesFloor Ceiling
2.8/3.6/4.5/5.6/7.1kWUltra Thin Unit Body 199mm
8.0/9.0/11.2/14kW
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YVFVXH028WAR--GX 2.8 10 220-230V/1Ph/50-60Hz 990*655*199YVFVXH036WAR--GX 3.6 12 220-230V/1Ph/50-60Hz 990*655*199YVFVXH045WAR--GX 4.5 15 220-230V/1Ph/50-60Hz 990*655*199YVFVXH056WAR--GX 5.6 19 220-230V/1Ph/50-60Hz 990*655*199YVFVXH071WAR--GX 7.1 24 220-230V/1Ph/50-60Hz 990*655*199YVFVXH080WAR--GX 8 27 220-230V/1Ph/50-60Hz 1298*700*240 YVFVXH090WAR--GX 9 31 220-230V/1Ph/50-60Hz 1298*700*240 YVFVXH112WAR--GX 11.2 38 220-230V/1Ph/50-60Hz 1580*700*240YVFVXH140WAR--GX 14 48 220-230V/1Ph/50-60Hz 1580*700*240
185mm Height Ultra Thin Design
Built in Drain Pump
Bottom or Rear Air Return
Install With or Without Discharge & Return Plenum
Static Pressure Setting 0/30Pa
6 Models Ranging from 2.2kW to 7.1kW
15
VIndoor FeaturesSlim Low Static Pressure Duct
2.2/2.8/3.6kW
4.5/5.6/7.1kW
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YV3VXH022WAR--GX 2.2 8 220-230V/1Ph/50-60Hz 610*185*500YV3VXH028WAR--GX 2.8 10 220-230V/1Ph/50-60Hz 610*185*500YV3VXH036WAR--GX 3.6 12 220-230V/1Ph/50-60Hz 610*185*500YV3VXH045WAR--GX 4.5 15 220-230V/1Ph/50-60Hz 1105*185*500YV3VXH056WAR--GX 5.6 19 220-230V/1Ph/50-60Hz 1105*185*500YV3VXH071WAR--GX 7.1 24 220-230V/1Ph/50-60Hz 1105*185*500
220mm Height Ultra Thin Design
Optional External Drain Pump
Bottom or Rear Air Return
Install With or Without Discharge & Return Plenum
Knock Down Coil From Bottom
Static Pressure Setting 0/20Pa
6 Models Ranging from 2.2kW to 7.1kW
16
VIndoor FeaturesLow Static Pressure Duct
2.2/2.8/3.6kW
4.5/5.6/7.1kW
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YVDVXH022WAR--GX 2.2 8 220-230V/1Ph/50-60Hz 610*220*500YVDVXH028WAR--GX 2.8 10 220-230V/1Ph/50-60Hz 610*220*500YVDVXH036WAR--GX 3.6 12 220-230V/1Ph/50-60Hz 610*220*500YVDVXH045WAR--GX 4.5 15 220-230V/1Ph/50-60Hz 1105*220*500YVDVXH056WAR--GX 5.6 19 220-230V/1Ph/50-60Hz 1105*220*500YVDVXH071WAR--GX 7.1 24 220-230V/1Ph/50-60Hz 1105*220*500
Built in Drain Pump for 5.6/7.1/8.0kW
Optional External Drain Pump for 9.0/11.2/14kW
Rear Air Return with Plenum
Flexible Discharge Duct Connection
Static Pressure Setting 50/96Pa or 80/120Pa
6 Models Ranging from 5.6kW to 14kW
17
VIndoor FeaturesMedium Static Pressure Duct
5.6/7.1/8.0kW50/96Pa
9.0/11.2/14kW80/120Pa
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YVEVXH056WAR--GX 5.6 19 220-230V/1Ph/50-60Hz 990*300*655YVEVXH071WAR--GX 7.1 24 220-230V/1Ph/50-60Hz 990*300*655YVEVXH080WAR--GX 8 27 220-230V/1Ph/50-60Hz 990*300*655YVEVXH090WAR--GX 9 31 220-230V/1Ph/50-60Hz 1135*270*742YVEVXH112WAR--GX 11.2 38 220-230V/1Ph/50-60Hz 1135*270*742YVEVXH140WAR--GX 14 48 220-230V/1Ph/50-60Hz 1135*270*742
Optional External Drain Pump
Rear Air Return With Plenum
Flexible Discharge Duct Connection
Static Pressure Setting 100/196Pa
8 Models Ranging from 5.6kW to 28kW
18
VIndoor FeaturesHigh Static Pressure Duct
5.6/7.1/8.0kW
22.6/28kW
9.0/11.2/14kW
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YVGVXH056WAR--GX 5.6 19 220-230V/1Ph/50-60Hz 970*360*875YVGVXH071WAR--GX 7.1 24 220-230V/1Ph/50-60Hz 970*360*875YVGVXH080WAR--GX 8 27 220-230V/1Ph/50-60Hz 970*360*875YVGVXH090WAR--GX 9 31 220-230V/1Ph/50-60Hz 1350*360*875YVGVXH112WAR--GX 11.2 38 220-230V/1Ph/50-60Hz 1350*360*875YVGVXH140WAR--GX 14 48 220-230V/1Ph/50-60Hz 1350*360*875YVGVXH226WAR--GX 22.6 77 220-230V/1Ph/50-60Hz 1610*360*840YVGVXH280WAR--GX 28 96 220-230V/1Ph/50-60Hz 1610*360*840
Install with Other Indoor Units Together
Static Pressure 100Pa
Operation Range -5~43 ℃
Installed Capacity Must Less Than 30% of Outdoor Units
3 Models Ranging from 14kW to 28kW
19
VIndoor FeaturesFresh Air Unit
14kW100~180Pa
22.6/28kW100~200Pa
Model NameNominalCapacity
kW
NominalCapacity[kBTU/h]
Power SupplyDimension (mm)
W*H*D
YV4VXH140WAR--GX 14 48 220-230V/1Ph/50-60Hz 1350*360*875YV4VXH226WAR--GX 22.6 77 220-230V/1Ph/50-60Hz 1750*360*840YV4VXH280WAR--GX 28 96 220-230V/1Ph/50-60Hz 1750*360*840
Efficient Heat Recovery Air Processing
Heat Recovery Media Element
Is Replacement As Spare part
4 Models Ranging from
150CMH to 1000CMH
20
VIndoor FeaturesHeat Recovery Ventilator
Warm, Exhaust Air from Inside
Pre-heatedFresh Air to Inside
Fresh Air From Outside
Exhaust Airto Outside
Illustration of how it works
Model NameNominalCapacity
CMH
NominalCapacity
CFMPower Supply
Dimension (mm)W*H*D
YV6VXH015CAR--GX 150 88 220-230V/1Ph/50-60Hz 940**276*685YV6VXH026CAR--GX 260 153 220-230V/1Ph/50-60Hz 1750*360*840YV6VXH080CAR--GX 800 471 220-230V/1Ph/50-60Hz 1227*387*1115YV6VXH100CAR--GX 1000 588 220-230V/1Ph/50-60Hz 1227*387*1115
21
Features & Benefits
22
Features & BenefitsOverview
Five Star FeaturesEnergy
Efficient
Broad and Flexible Indoor
Offering
Reliable Accurate
Temperature Control
Modular and
Compact Design
- Saves Energy
- HealthyEnvironment
- Low OperationCosts
Comfortable -Environment
Easy to Transport -And Install
23
180°vector dc inverter drive technology High precision control, variable frequency drive from 20 to180Hz
Sine wave current drive, efficiency improve 17% comparing to conventional rectangle wave
Inverter module equipped with heat dissipating fan, enhancing compressor reliability
Features & BenefitsEnergy Efficient
Conventional Drive Control 180° Vector Drive Control
24
High efficiency heat exchanging technology
Outdoor high efficiency four way air return heat exchanger design
The compressor and condenser are placed in separated chamber
High efficiency heat exchanger design
Efficient φ8 inner grooved tube and 0.11 hydrophilic aluminum coil fin, corrosion and oxidation resistance treatment
Features & BenefitsEnergy Efficient
25
High efficiency DC Inverter Scroll Compressor
DC Inverter Scroll Compressor from Mitsubishi Electric
Equipped with a “Frame Compliance Mechanism” that allows movement in the axial direction of the frame supporting the cradle scroll. This greatly reduces both leakage and friction loss, ensuring very high efficiency throughout the whole speed range
Features & BenefitsEnergy Efficient
26
64 stage speed adjustment DC Fan Motor
Efficiency increase 45% comparing with AC motor and power input largely decrease
64 stage speed adjustment plus DC inverter drive, stabilizing compressor discharge pressure and suction pressure to ensure high system reliability
Features & BenefitsEnergy Efficient
27
Two stage deep sub cooling technology
1st stage sub cooling added a sub cooling coil to Condenser
2nd stage sub cooling added a stand alone Sub Cooler
After further cooling, sub-cooling degree can be up to 30℃ , with the heat exchanging capacity per unit mass of refrigerant improved by 46% and flow resistance reduced by 55%, and running efficiency improved by 9%
Features & BenefitsEnergy Efficient
Condenser
1st Stage
2nd Stage
28
Patent flow channel design
Special design of streamline fan , airflow improved by 17.5%, noise reduced 3dB/A compare to previous product
The new fan reduce air loss and increase heat exchange efficiency
Features & BenefitsEnergy Efficient
29
100% Independent Fresh Air System
Fresh air unit can be installed with other indoor units, and introduce the outdoor fresh air into indoor
Features & BenefitsHealthy Environment
30
3-in-1 High Efficient ESF Filter
Effectively purifying indoor air by trapping harmful dust and removing unpleasant odors
Features & BenefitsHealthy Environment
Note: ESF filter is only optional for High Wall and Floor Ceiling
31
The first 2-stages oil separation and cross oil return technology in the industry – Inside module 1st stage oil separation: built-in oil separating unit ,greatly reduced the oil from the
compressor discharge
2nd stage oil separation: external oil separator to separate the small amount oil from discharge
Cross oil return: on the one hand to ensure the own compressor oil (red line) ,on the other hand to supply the redundant oil to other compressor (blue line)
Features & Benefits Reliable
Inverter Compressor
Oil Separator
Fixed Compressor
32
High pressure difference oil equalization – Among modules
Using the pressure difference between suction and discharge ,to realize fast oil balance between module
Cycle every 15 minutes
Features & Benefits Reliable
CompressorSuction Line
Separator
33
Duty cycle operation to extend the system lifetime (combination model)
The outdoor units operating changes every 24 hours
Outdoor units start in turn and operation time can be balanced
Inverter compressor lifetime can be extend maximum 3 times
Features & Benefits Reliable
First time operation Second time operation Third time operation
1 2 3 3 1 2 2 3 1
34
Backup operation
If one outdoor unit get into malfunction, the other units continue to operate without affecting the whole system
Features & Benefits Reliable
35
Low noise and Night silent running
Machinery chamber is separated from air supply chamber; built-in high efficient muffler in the machinery chamber greatly reduce the compressor noise
The night silent running function can be set on the outdoor PCB. The noise can be reduced by 8 dB/A at most
Features & BenefitsComfortable Environment
Note: The night silent mode has to be turn on and off manually
36
Intelligent defrost Conventional defrost control(left) heating operation after all the outdoor finish the
defrost
Amazon outdoor defrosting(right) help each other to accelerate defrosting, not only accelerate defrosting speed, but also reach rapid heating
Features & Benefits Comfortable Environment
Defrost rapidly Defrost clean
Heat support
Module 1
Module 2
Module 3
Indoor temperature fluctuations small
Condenser heat absorption
Condenser heat dissipation
37
Precise temperature control
DC inverter control, temperature could be controlled precisely within range of ±0.5℃
Features & Benefits Comfortable Environment
38
Easy transportation
Outdoor footprint only occupy 0.74m^2(8/10hp) and 1.04m^2 (12/14/16hp)
Can lift with elevators and save lots of transport cost and time
Features & BenefitsModular & Compact Design
39
Flexible installation
Long pipe length and large drop
Total 300m liquid refrigerant piping length
Max.175m refrigerant piping length for single way
Max.50m height drop when outdoor unit is above indoor unit
Max.40m height drop when outdoor unit is below indoor unit
Max.15m height drop between indoor units under same outdoor unit
Features & Benefits Modular & Compact Design
40
Outdoor high external static pressure
Up to 50Pa and can be installed at different floors
Features & Benefits Modular & Compact Design
50Pa ESP
41
Controllers and BMS
42
Controllers and BMSSolutions Overview
Stand Alone Controllers Central Controllers
BacNet ConverterLonWorks Converter
Stand Alone Controllers Auto/Cool/Dry/Heat/Fan Mode Setting
Auto/Low/Mid/High Fan Speed Setting
Temperature Setting
Clock and Timer Setting
Central Controllers Group Control & Unit Control
Weekly and Monthly Timer Management
Power Metering, System Running Recording and Report
BMS Converters BMS Integration
Group Control & Unit Control
Failure Code Display, System Running Recording and Report
Remote Monitoring
43
VControllers & BMSFunctions Overview
Wireless Controller LCD Display
Standard offer for High Wall and Console Units
Optional for Duct, Cassette and Floor Ceiling Units
Wired Controller LCD Display
Standard offer for Duct, Cassette, Floor Ceiling,
and Fresh Air Units
Not optional for High Wall and Console Units
Can also work as a group controller controlling up
to 16 indoor units
44
VControllers & BMSIndividual Controllers
45
VControllers & BMSTouch Screen Central Controller
IGU05Protocol Translator
Max.64 indoor units under one IGU05(one modular or combination outdoor system)
YCZ-A003Touch Screen Central Controller
Max
. 32
un
its
of
IGU
05
No.1
No..2
No..32
220-240V/1/50-60Hz
~
Touch Screen Central Controller can control up to 128 indoor units
No.1 No..2 No..64
RS
-485
max
. 10
00m
Note: (number of IGU05) x (number of indoor units under each IGU05)should be no more than 128
46
VControllers & BMSCentral Controller With Monitor Software
IGU02Protocol Translator
Max
. 32
un
its
of
IGU
02
No.1
No..2
No..32
Central Controller With Monitor Software can control up to 400 indoor units
No.1 No..2 No..40
RS
-485
max
. 10
00m
RS
-232
or
US
B
HCM-01Central Controller With Monitor Software
Monitor Software
Ammeter
Ammeter
Ammeter
Max.40 indoor units under one IGU02(one modular or combination outdoor system)
Note: (number of IGU02) x (number of indoor units under each IGU02)should be no more than 400
47
VControllers & BMSLonWorks
IGU06Protocol Translator
LonWorks Converter can control up to 32 indoor units
No.1 No..2 No..32
RS
-485
max
. 10
00m
Lo
nW
ork
s
IGU07 LonWorks Converter
JCI Net Control Engine
Note:1. One LonWorks IG07 Converter can Only work with ONE Protocol Translator IGU062. Please use LonTalk Card U10(75010R) to commissioning NCE & IGU073. Please buy U10(75010R) locally from Echelon, suggestOne branch office getting one Card
JCIMetasys
TC
P/
IP
Max.32 indoor units under one IGU06(one modular or combination outdoor system)
U10(75010R) LonTalk Card
48
VControllers & BMSBacNet/IP
IGU02Protocol Translator
Max
. 20
un
its
o
f IG
U02
No.1
No..2
No..20
BaNet/IP Converter can control up to 72 indoor units
No.1 No..2 No..40
RS
-485
max
. 10
00m
fo
r ea
ch
gro
up
Bac
Net
/IP
HCM-03 BacNet/IP Converter
Ammeter
Ammeter
Ammeter
JCIMetasys
TC
P/
IP
JCI Net Control Engine
Note: (number of IGU02) x (number of indoor units under each IGU02)should be no more than 72
Max.40 indoor units under one IGU02(one modular or combination outdoor system)
Top Related