airfow management solutions
predictability, reliability & eciency or your data center
8/6/2019 Airflow Management Brochure
2/16800.225.7348 www.wrightline.com
For years, data center managers have been told they can
either have a highlyreliable data center or a highlyefcient
data center, but not both. Its a similar story to the automobile
market where or decades, Detroit told the world, you caneither buy a low cost or a high quality car. The Japanese
showed the world that you can indeed oer a car that is both
low cost and high quality, changing the dynamics o the car
industry orever.
At Wright Line, we oer solutions that improve both
eciency and reliability. In order to eectively uture proo
your critical inrastructure you must maintain a predictable
environment. This not only includes the ability to direct and
separate hot and cold air, but also to accurately measure the
perormance o your design to ensure it is operating
as planned.
Wright Lines comprehensive portolio o vendor-neutral
airfow management solutions are designed to work within
your new or existing data center environment. Whether you
have Wright Line enclosures, an alternative brand or a mixo enclosures rom various manuacturers, these products
will help solve your airfow management issues and provide
a much more predictable operating environment which is
essential to delivering both eciency and reliability.
Although it is always important to look at the entire data
center when optimizing airfow, solutions can be implemented
in stages at the rack, row and room level depending on:
Theproblemsyouarelookingtoaddress
Thebudgetconstraintsyouareoperatingunder
Thetimeframeinwhichasolutionisrequired
Wright Lines Innovative Airow Management Solutions:
Through the separation of hot and cold air, you dramatically increase the
predictability of your data center s performance thereby enabling you to:
Moreeffectivelyandefcientlyutilizeexistingphysicalinfrastructure
and cooling capacity
Activelycontrolandnormalizesupplytemperature;eliminating
recirculationandstratication Domorewithlessinasmallerdatacenterfootprintwithincreasing
high-density IT loads
Eliminatestranded physical, electrical or mechanical capacity
Fromheatcontainmentandcold-aisleisolationtototalairow
managementbestpractices,WrightLinecanhelpimproveyourphysical
ITinfrastructurebyprovidingeco-friendlysolutionsthatwillincreaseyour
neworexistingdatacentersefciencyandreliability.
Table of Contents:
Heat Containment System Products 3-6
Independent Containment System 7
EndofRowDoors 8
AisleContainmentCeiling/Duct 9
EndofRowCurtains 10
CRACCollars 10
BlankingPanels 11
AirowDirectors/Managers 12
HighFlowDoors 13
UniversalAirSealKit 13
TowerofCool 14
RaisedFloorGrommets 14
CFDModelingServices 15
Ask your account representative or more inormation.
The Optimized Data Center
sComputational Fluid Dynamics (CFD) model o an optimized data center illustrating cold-aisle isolation and Wright Lines
Heat Containment System (HCS). See CFD Services on Page 15 or more inormation.
8/6/2019 Airflow Management Brochure
3/16800.225.7348 www.wrightline.com
Heat Containment System (HCS)
or Paramount and Vantage S2 enclosure systems
sHCS allows or your existing cable management without the
interruption o re-routing or disconnecting cables and power. HCS
shown here on Wright Line's Paramount enclosure system.
sWright Line's Paramount enclosure with integrated HCS.
PhotocourtesyofHumana
Wright Line's Heat Containment System (HCS) is a simple, scalable and low cost solution to
cool up to 25kW or more per enclosure without the expense o adding supplemental CRAC
units to your data center. This patented technology is available on Wright Line's Paramount
and Vantage S2 enclosure systems and can also be eld retrotted to most manuacturers'
enclosures. The HCS contains and directs the heat exhaust o your IT equipment through
the chimney that is attached to the top rear o the enclosure. The hot air is then ducted to
your existing CRAC units through the plenum ceiling or high air returns.
Chimney
Chimney base
Optional ans (2)
See Page 4
Tool-less an access door
s
s
s
s
8/6/2019 Airflow Management Brochure
4/16800.225.7348 www.wrightline.com
Heat Containment System (HCS)
sComputational Fluid Dynamics (CFD) model showing
airow through active HCS System.
sBy using two optional ans, you can
increase your airow up to 2,600 CFM.
Wright Line's HCS is:
ScalableItcanbeadaptedtoexistinginfrastructurestoincreaserackutilizationasyourcapacitydemandsgrow.
PredictableItseparateshotexhaustairandcoldsupplyair;dramaticallyincreasingthereliabilityofthedatacenter.
EfcientAllowinghotterairtoreturndirectlytotheCRACs,increasingtheirefciencybyoperatingatahigherDeltaT(T).
ReliableItextendsexistingcoolingcapacitythroughoutthedatacenter;freeingupstrandedassetsandloweringoperationalcosts.
FlexibleItdoesnotrequireyoutoalterexistingenclosurelocationsandisalsoeld-installableonthird-partyenclosures.
HCS Flexible Return Duct
For data centers unable to accommodate steel chimneys, an alternative
solution or controlling chaos cooling is Wright Lines new Flexible
Return Duct. A simple interace easily connects to the top o the Heat
Containment System chimney. Flexible 10" ducts are clamped to the
interace and a 2' X 2' ceiling tile , which is mounted to the plenum ceiling
to create a closed loop system.
DuctingisV-0ratedandselfextinguishing. CeilingtileisavailableinNugreytomatchexistingtiles.
Ductingcanbecutintheeldforcustomts.
Eachductcomeswithfourclamps.
Ductsarepositioneddirectlyoverthefanformaximumairow.
sThe ideal solution or clients having enclosures that are o-grid
rom drop ceilings, where obstacles preclude the use o sheet metal
chimneys or have uneven ceilings throughout their data center.
8/6/2019 Airflow Management Brochure
5/16800.225.7348 www.wrightline.com
Bypass airfow and mixing lead to ineciencies, shorter
lie cycles or equipment and increased operating cost.
Managing airfow to enclosures with varying densities,
varying building inrastructure and sporadic hot spots ischallenging, but can now be solved using a simple solution.
Wright Lines HCS pressure based system with active
airfow, when combined with best practices, improves
perormance metrics considerably. Allocating the correct
amount o airfow at known intake locations is the key toreducing energy consumption while increasing equipment
perormance. Best practices such as blanking panels, proper
perorated tile placement and the reduction o bypass
airfow must be employed to ensure desired results.
Active Thermal Management System
Active Airfow Manager
Features & Benets:
SNMPmanageddevicewithuser-friendlywebinterface.
Controllercontinuouslymonitorspressuredifferentialsto
ensurethatairenteringtheenclosureandserveris
properlyremoved. LocalLEDsindicatefanstatusincludingfanfailand
overtemperature.
Manageupto64PeerActiveAirowManagers
viaEthernet.
TwointegratedtemperaturesensorswithEmail
alertcapabilities.
Redundantpowerinput;C13plugtypeisrequiredfor
eachinput,90-240VACsuppliedbyenclosurePDU(s).
ControllerisRoHScompliant.
Features & Benets:
Dual90-264VACInput(C14).
1Urack-mountapplication.
Uptofourtemperatureprobesandoneinternalprobe.
Webaccess,EmailandSNMPalerts.
Displayindicatestemperature,operating
setpointandfanspeedpercentage.
sThe Active Airow Manager easily mounts inside a HCS chimney
base. This device measures pressure dierentials and temperature to
regulate an operation.
sWright Line's Active Thermal Management System manages
power to your an systems in a 1U orm actor. Works with
optional ans shown on Page 4.
Manage power to your an systems based on a set operating
temperature. The ATMS-I (Active Thermal Management
System) has dual 90-264 VAC input or redundancy in a 1Urack-mount enclosure. Connect up to our temperature
probes and select operating temperature or automatic an
speed adjustment. The local display indicates temperature,
operating set point and an speed percentage.
8/6/2019 Airflow Management Brochure
6/16800.225.7348 www.wrightline.com
Heat Containment System
or third-party enclosure systems
Features & Benets:
Scalable Heat ContainmentImplementheatcontainmentwithminimal
interruptiontooperationsbybuildingupfromexistingenclosureswithout
havingtore-routeordisconnectcablesandpower.
Increased Rack CapacityByisolatingthehotexhaustairfromthecold
supplyair,youcanloadover25kWofequipmentinanenclosure.
Save White Space No additional air conditioners or other space
consuming supplemental equipment is required at the perimeter of the data
center,in-roworoverhead.
Increase CRAC Cooling EfciencyHotexhaustairisdirectedbacktotheCRACintakeatahigherTallowingyourACunitstooperatemoreefciently.
Greatforyour"green"initiatives.
Create a Predictable EnvironmentEliminatingchaosairowwillresult
inamorepredictableoperatingenvironment,allowingyoutodriveefcient
energyusewhilecreatingareliableinfrastructureforconstanttechnology
moves,additionsandchanges.
sBy adding the Wright Line Heat Containment System to your existing enclosures, you realize
enormous equipment and cost savings while maintaining your valuable data center space.
Shown here on APC, CPI, Rittal, Compaq and Knurr enclosures.
Converting existing enclosures to
the HCS allows you to eliminate the
incremental capital expense associated
with having to add more CRAC units
or other supplemental cooling. The
HCS manages the hot air exhaust,
which prevents mixing, thereby
allowing the available cooling already
produced by your AC units, to be
used much more eciently. Optional
ans eliminate the issue o backfow
rom a pressurized plenum, generallyassociated with passive-only systems.
8/6/2019 Airflow Management Brochure
7/16800.225.7348 www.wrightline.com
Independent Containment System
Features & Benets:
Scalable DesignTheabilitytoextendaisleswithload
growthmakestheICSanidealsolutionforco-locationand
otherhighlyevolvingdatacenterenvironmentsthatrequire
on-the-ymodications.
Containment IntegrityVerticalblankingpanelsensure
containmentintegritywhenracksarepartiallydeployed
withintherowandareeasilyremovedinsectionstoallow
quickinstallationandpositioningofnewITracks.
Rack AgnosticAbilitytosupportvirtuallyanybrandof
serverornetworkrackinanydepth,heightandsizewith
on-demandrecongurationoftherow.
Cold Aisle CompatibleEasilydeployedasacold
aislecontainmentsolutionwithorwithoutadownow
chimneysystem.
Increased ROIModular,building-blockdesignoffers
completeexibilityandroomforgrowthincreasingyour
initialReturnonInvestment(ROI).
sCeiling structure allows or the installation o additional 2' x 2'
chimneys as IT loads increase.
The culmination o Wright Line containment
strategies is its patent-pending Independent
Containment System (ICS), a ree-standing, scalable,sustainable and vendor-neutral containment solution
or high-density computing environments.
Designed to provide maximum fexibility in all
environments, the ICS, assembled within the
ootprint o a standard aisle, is constructed with
a tubular steel rame. The rames structure is
designed to be reestanding and meets seismic
NEBSZone4standards.Additionally,itacceptsa
varietyofWrightLinesEndofRowDoors(p.10)
including ca style and single-swing models.
Aisle ceilings (p. 11) are constructed o a light-weight
steel rame and clear Lexan panels allowing ambient
room light to illuminate the ICS aisle, eliminating the
need or energy-consuming supplemental lighting.
The ceiling accepts 2' x 2' adjustable chimneys which
can be added anywhere on the ceiling structure as
IT loads increase.
sShown above Independent Containment System eaturing End o
Row, Ca-style doors and vertical blanking to accommodate third-party
enclosures.
8/6/2019 Airflow Management Brochure
8/16800.225.7348 www.wrightline.com
EndofRowDoorsareasimple,cost-effectivesolutionto
improve eciency while lowering overall operating costs.
End o Row Doors
Features & Benets:
Ease of Installation Field-installable, rack-integrated and
freestandingoptionsavailable.
Rack AgnosticFlexibleenoughtoinstallalmostanywhereon
anymanufacturer'sbrandenclosure.
Improve Efciency and Predictability Increases cold air
intakeefciency,fromthebottomoftheenclosuretothetop,
withinthecoldaisle.Decreasewastedairbyasmuchas70%.
Variety of Door Models Choose from three styles of
doors from simple containment curtains to building-integrated
caf-styledoorsandcontainmentwalls.
Minimize Air Re-mixingCost-effectivelyminimizeair
mixingbetweenthehotandcoldaislewhilekeepingthe
uniformcoldairsupplyinfrontoftheserversforalonger
periodoftime.sCa style doors allow or easy, hands-ree access to the row.
sWright Line's End o Row Doors solution helps achieve aisle containment.
Industry studies indicate that an estimated
60% o the cool air supplied to traditional
data centers is wasted because it bypasses theintended IT equipment and returns directly to
the hot air intake o the CRAC. Adapting a
containment strategy increases the eectiveness
ofthecoldair.Eliminatingwastedaircaneither
reduce the amount o cold air you need to
supply to the data center or it can allow you to
increase your IT load.
EndofRowDoorscreatemoreefcientcold
aisles by blocking an obvious cold-air escape
route and entry or hot air re-circulation and airmixing. This allows you to set a higher overall
temperature within the data center and enables
air-side economization to be used a greater
percentage o the time.
8/6/2019 Airflow Management Brochure
9/16800.225.7348 www.wrightline.com
Aisle Containment Ceiling and Duct
sThe Aisle Containment Ceiling's Lexan panels are cut to size or
your specifc requirements and can be "nested" or adjustable widths.
Wright Line's Aisle Containment Ceiling is comprised o V-0 rated Lexan panels
and mounts easily to the top o Paramount, Vantage S2 and third-party enclosures.
The ceiling system can accomodate dierences in rack heights, row spacing and it's
sel-supporting structure allows or easy rack changes within the row. Holes can be
strategically drilled in the panels to accommodate any type o re suppression system.
The rack-integrated Aisle Containment Duct
works seamlessly with the Aisle Containment
Ceiling system. Integration with the air
conditioning supply or exhaust is easily achieved
with the duct's modular and scalable design.
sThe Aisle Containment Ceiling, used in conjunction with the Aisle Containment Duct and
End o Row Doors, completes Wright Line's total aisle containment solution.
sThe Aisle Containment Duct is modular
and scalable to ft your unique requirements.
8/6/2019 Airflow Management Brochure
10/16800.225.7348 www.wrightline.com
End o Row Curtains
CRAC Collars
Given the ever increasing heat loads in todays data centers, solutions that
eectively control airfow dynamics are in high demand. At a minimum,
partially containing air within the aisle will not only increase the lie oyour valuable IT equipment but help decrease your rising energy costs.
EndofRowCurtainsallowyoutocreateandmaintainproperaisle
isolationinyourdatacenter.Dependingonyourspecicneeds,Endof
Row Curtains can be installed at the rack level, with or without an Aisle
Containment Ceiling, or rom foor to room ceiling.
The CRAC Collar or downfow systems, used
in conjunction with data center containment
strategies is integral to Wright Lines total
containment solution. By containing and directing
the warm plenum air directly to your air
conditioning systems, you increase eciency and
equipment perormance while reducing overall
energy consumption.
The CRAC Collar eatures an integrated design,
comprised o steel panels that mount easily to
the top o any CRAC unit with easy, tool-less
installation. Collars allow ront lter installation
and service and completely integrate with airfow
dampening devices. This closed-loop integration
o the air conditioning supply or exhaust
completes the modular airfow containment
strategy in the data center, resulting in a more
energy-ecient operation.
sEnd o Row Curtains easily mount to
enclosure tops with a mounting bracket.
HTool-less access panels allow quick and easy installation on
your existing CRAC units.
HHinged access panels allow or easy cleaning, flter replacements and
maintenance. Shown here with optional Backow Bae.
cold aisle
hot aisle
CRAC
cold aisle
Typical data center confguration using
oor to ceiling curtains to acheive total
cold aisle isolation.
s
8/6/2019 Airflow Management Brochure
11/16800.225.7348 www.wrightline.com
In today's dynamic data center environment, IT
equipment is rereshed on a requent basis. These
changes oten leave open U-space in the enclosurewhich can allow re-circulation o hot exhaust air back to
the equipment inlet. This can cause overheating o the
equipment and subsequent shutdown o servers when
the maximum temperature threshold is reached.
Blanking panels provide a quick, easy and cost-eective
solution to optimize air circulation within an enclosure
while maintaining high aesthetics. Wright Line oers
blanking panels in a variety o styles including tool-less,
mechanically astened, clear and with cable pass through
options in steel as well as plastic . The width meetsEIA-310-Dstandardsandcomesinvariousheights
(depending on style). Most panels are bulk packed in
quantities o 10 and 100.
Blanking Panel Solutions
Features & Benets:
Signicantlyreducesre-circulationofhot
exhaustairtotheequipmentinlet
Addstotheoverallaestheticsofthedatacenter
1U,2U,3U,4U,5U,6U,7U,8Uand20U
(dependingonstyle)
EIA-310-Dcompliantfor19"equipment
Color: Black steel, black plastic, clear plastic
Availableintool-less,mechanicallyfastened,clear and cable pass through styles
sTool-less plastic blanking panels are a low cost but necessary solutionor preventing re-circulation and optimizing airow in your rack.
sBrush strip models allow routing o cables through the panel.
sVertical blanking panels seal open spaces and prevent bypass airow
in areas that are traditionally difcult to seal. They can also be adapted
or cable management.
sAdjustable blanking panels, oered in two sizes (7-12U,
12-22U) easily adapt to your hardware requirements.
8/6/2019 Airflow Management Brochure
12/16800.225.7348 www.wrightline.com
Properly cooling network devices that require side-to-side airfow in an enclosure
can present many challenges. Air recirculation that occurs in an enclosure can cause
temperatures to rise signicantly causing overheating o the devices. Wright Line'sAirfow Managers and Directors draw air into the enclosure, redirect the air to the
side intake o the device and allow the removal o the hot air out o the enclosure.
These solutions extend equipment lie by providing proper inlet temperatures and
eliminating harmul recirculation within the rack.
The Airfow Director is designed or
Cisco6509/6513/9513andJuniper
8216 switches that have side-to-side
cooling. The intake allows cold air to
be drawn rom the cold aisle, through
the Airfow Director and to enter theswitch rom the side. The switch's
ans then pull the cool air across the
device and exhaust the warm air out
the opposite side.
The Airfow Manager is designed to be used on Cisco Catalyst 4948
switches.ItcanbeutilizedinmostenclosuresthatmeettheEIA-310-D
specication.
The Airfow Manager kit includes everything needed to mount the switch,control airfow and manage cabling. This 2U device can be mounted to
ace either the hot or cold aisle while properly directing airfow.
Airfow Directors / Managers or Side-intake Switches
Features:
Helpseliminateoverheatingofnetworkracksandothernearby
equipmentbyallowingfront-to-rearairowthroughtheswitch.
Improvesefciencybypreventinghotexhaustairfrommixing
withcoldintakeair.
Resolvesthedifcultissueofhowtomountaswitchwithunique
airowrequirements.
sOverhead view o Airow Manager
with optional Cable Manager.
sAirow Director or Cisco and Juniper switches.
sAirow Manager or Cisco 4948 switch.
sSide view o Airow Director.
8/6/2019 Airflow Management Brochure
13/16800.225.7348 www.wrightline.com
Wright Lines High Flow Doors oer exceptional airfow with 75%
peroration, a 19% increase over the industry standard. In addition to
increased perormance, the unique peroration pattern results in a reduction
o raw material consumption by over 60% which means less waste in the
manuacturing process a great green benet.
Doors are available as let or right hinged and are also eld
reversible. The High Flow peroration is also available or
the rear door and can be ordered as ull or split. The doors
eature tool-less door removal, a brushed aluminum door
pull and a variety o locks.
Paramount High Flow Doors
Universal Air Seal Kit
Stop the cold air rom escaping through small openings in the doors,
sides, bottom or top o your enclosure. This low cost, adaptable oam
solution can quickly be sized to t into any crack or opening. The Air Seal
Kit can easily be retrotted to an existing rack, regardless o manuacture,
and will allow you to cool equipment more eciently in your enclosure.
sReducing bypass airow and particulate matter is critical to maximize
efciency, contain cost and minimize carbon ootprint in the data center.
sWright Line's Air Seal Kit is
a simple, inexpensive solution
or preventing bypass airowin gaps around or within
enclosures.
Features & Benets:
Easytoinstallandconformstospacesthataretraditionallydifculttoseal
AnintegralcomponentofWrightLine'sAirowManagementSolutions,
thisproductreinforcesthecompany'scommitmenttooffercosteffective
green solutions
8/6/2019 Airflow Management Brochure
14/16800.225.7348 www.wrightline.com
KoldLok Raised Floor Grommets
By installing KoldLok Raised Floor Grommets, you
can optimize the eectiveness o existing cooling
equipment and manage increasing heat loads.
The patented KoldLok sealing system specically
addresses bypass airfow and its detrimental eect
on data center cooling.
Features & Benets:
Eliminateupto98%ofbypassairow.
Increasestaticpressureandairow
throughperforatedoortilesandgrates.
Bleedstaticchargebuildupoffofcables.
Easy,tool-lessinstallation,requiringno
downtimetoinstallorre-cable.
sExtended raised oor grommet or
long, narrow, above-oor perimeter cuts.
sIntegral raised oor grommets installed in oor
tiles prior to equipment installations.
For applications where a ull HCS deployment
is unnecessary, the patented Tower o Cool,
which utilizes High Delta Temperature Cooling(HDTC), can be a perect alternative. The
Tower o Cool eciently cools 10kW o
equipment within 44U, by incorporating
the building air conditioning system and
the enclosure into one closed-loop cooling
system. The Tower o Cool is also the perect
solution or providing supplemental spot
cooling in legacy data centers.
By preventing stratied air rom entering
the top o the enclosure, the Tower o Cooldistributes cold air which allows equipment
to run at lower temperatures, resulting in
increased hardware reliability.
Paramount Tower o Cool
sThe Tower o Cool,
using specialized doorsand ans, captures cold
air rom the raised oor
plenum and distributes itthroughout the rack.
8/6/2019 Airflow Management Brochure
15/16800.225.7348 www.wrightline.com
Wright Lines innovative Computational
Fluid Dynamics (CFD) Modeling Service
provides a comprehensive approachto modeling the airfow, temperature,
static pressure and energy prole o
dynamic, critical environments. Using
Future Facilities 6SigmaDC sotware,
we construct a virtual representation
o your data center. This representation
models the impact o load distribution
within the acility, as well as the fow o
hot and cold air within the space. It also
illustrates how to increase rack densities
and server installations without creatingadditional hot spots and airfow issues.
Providing act-based decisions aimed
at improving operational eciency and
reliability, the CFD modeling analysis is
essential or creating and operating a
more predictable data center.
The service compares and substantiates
which design decisions will maximize
your data center fexibility, scalability and
resilience. It enables you to explore thebest possible options or IT and acility
growth, create a calculated plan and
avoid major capital commitments and
costly design/implementation mistakes.
Pricing or Wright Lines CFD Services is based on specic
customer requirements and there are several levels o customized
service a customer can choose rom. A pre-quote consultationand/or walk-through by a Wright Line CFD Team member is
advised to determine the scope and level o CFD service required.
Features:
Fourlevelsofservice.
State-of-the-artsoftwareandtools.
Certiedtechnicians.
Detailedreporting.
Computational Fluid Dynamics Modeling Services
sStream line plot showing temperature o air as it ows throughout the data center.
Plots can be animated to illustrate direction o ow.
sWright Line can provide extensive perormance
details o your entire data center down to specifc
devices at the rack level.
sIllustration shows synchronized comparison o rack inlet temperatures
beore and ater HCS deployment.
8/6/2019 Airflow Management Brochure
16/16
Wright Line is a leading designer and
manuacturer o products and solutions or
data centers, command/control environments,
technical labs and government oce settings.
Incorporating expertise in airfow management
and data center containment, modular
workstation design and green standards,
Wright Line helps customers conserve capital,
adhere to technology requirements and
address sustainable energy needs.
Wright Line LLC
World Headquarters
160 Gold Star Boulevard
Worcester, MA 01606
Tel: 800-225-7348
508-852-4300
Fax: 508-365-6178
www.wrightline.com
TAB Canada
130 Sparks Avenue
Willowdale, Ontario
M2H 2S4
Tel: 800-667-4020
Fax: 888-257-5205
For additional international representation,
pleasecontactusat800-225-7348or
PleaseaskfordetailsofotherproductsfromWrightLine.Allproductsand company names are trademarks or registered trademarks of theirrespectiveholders.Everyefforthasbeenmadetoensurethattheinformationcontainedhereiniscorrect.Thecompanyreservestherighttomodifyproductspecicationswithoutpriornoticeandassumesnoresponsibilityforanyerrorwhichmayappearinthispublication.
Wright Line LLC 201009-17/WP-5K/4-10 Printed in the USA
Also see our ull line o products or
high-perormance workplaces.
Prole Advanced
Console System
Brochure
Optimedia
Storage System
Brochure
Contract No: GS-29F-0100G
Schedule 71 I:
OfceFurniture
SIN 711-2: Workstations,ComputerFurniture&Accessories
SIN 711-3:Filing & Storage Cabinets
SIN 711-94: Design&LayoutServices
SIN 711-95: InstallationServices
Contract No: GS-07F-0546T
Schedule 66:
ScienticEquipmentandServices
SIN 566-1: ModularLaboratoryFurnitureSystems
SIN 566-2: IndividualNon-ModularLaboratoryTables,
Cabinets, Benches & Carts
Top Related