ADDENDUM PROJECT Tri-C Exterior Signage ADDENDUM NO. 2
PROJECT NO. 16213.01 DATE 5/31/19
DRAWING NO. Click here to enter text. SPEC. SECTION 10400
TO Michele Crawford FROM Todd Nichols DESCRIPTION:
Addendum submitted to address questions and clarifications to the Westshore Exterior Signage package. The deadline for this RFP submission is extended to Wednesday June 5, 2019.
ATTACHMENTS:
Updated RFP Documents (pages 1, 2, 14)
- Title Sheet for reference - Bid Form updated to include allowance for drywall repairs (Appendix A)
RFI responses to received questions from interested vendors.
RFI 185 for reference and review.
Updated Appendix C- Exterior Signage Drawings. NOTE: Updated sheet numbers are clouded in title block.
Added Appendix H- Building sections for reference and review.
DISTRIBUTION:
As per Tri-C to Sign Vendors
1 | P a g e A d d e n d u m # 2 - R e v i s e d 5 / 3 1 / 1 9
CUYAHOGA COMMUNITY COLLEGE
Capital & Construction 700 Carnegie Ave.
Cleveland, OH 44115
Request for Proposal
ISSUED: May 20, 2019
Westshore Phase 2 Expansion
Tri-C Project No. C20169005
Bid Packages in this RFP: #18 Exterior Signage
PRE-BID MEETING DATE:
Friday May 24, 2019 @ 1:00 pm Westshore Campus SCHS 223 Conference Room
31001 Clemens Rd, Westlake, OH 44145
BID DUE DATE: Wednesday June 5, 2019 at 2:00P
2 | P a g e A d d e n d u m # 2 - R e v i s e d 5 / 3 1 / 1 9
Table of Contents
1 Introduction 1.1 Project Overview 2 Submitting Your Proposal 2.1 Contacts 2.2 Preparation of Proposal 2.3 Supplier Diversity 3 Administrative and Contractual Information 3.1 Award of Contract 3.2 Pricing 3.3 Delivery of Products and Services 3.4 Billing 3.5 Contract and License Agreements 4 Terms and Conditions 4.1 Entire Agreement 4.2 Time of Performance 4.3 Contract Amendments 4.4 Insurance 4.5 Indemnification 4.6 Other Benefits 4.7 Non-Disclosure 4.8 Publicity 4.9 Severability 4.10 Assignment 4.11 Observance of College Rules and Regulations 5 Additional Information & Requirements Appendix A: Bid Form Appendix B: Scope of Work Appendix C: Exterior Signage Document Issued 05-20-2019, Updated 05-30-2019 Appendix D: Close-out Checklist Appendix E: Delinquent Personal Property Tax Affidavit Appendix F: General Conditions- CM Advisor Project Appendix G: Project Labor Agreement (PLA) Appendix H: Building Wall Sections (for reference only) 1 INTRODUCTION
Cuyahoga Community College District (Tri-C) is issuing this Request for Proposal (RFP) and inviting responses for the goods and/or services described in the accompanying specifications according to the terms, conditions, and requirements herein. Vendors responding to this RFP shall be herein called the “Bidder.”
14 | P a g e A d d e n d u m # 2 - R e v i s e d 5 / 3 1 / 1 9
Appendix A – BID FORM
Westshore Phase 2 Expansion Tri-C Project No. C20169005
Bid Packages in this RFP:
Exterior Signage Having read the Request for Proposal, prepared by the Office of the Capital & Construction, Cuyahoga Community College District Office, Cleveland, Ohio 44115 and having also received, read, and taken into account any Addenda and likewise having inspected the sites of, and conditions affecting and governing the construction of the said project, the undersigned hereby proposes to furnish all material and to perform all labor, as specified in this RFP for the said work, for the following sum (please round all numbers to the nearest dollar):
Time of Completion
Overall Project Completion 08/30/19 BASE BID ITEM 1- Exterior Signage For the Sum of: $ _____________________________ Sum in words: _______________________________________________________________________________ ALLOWANCE ITEM A-1- Drywall repairs as needed from signage installation For the Sum of: $ ____$5,000_____________________ Sum in words: _____Five Thousand_______________________________________________________________ Acknowledge Receipt of All Addenda by Listing Each Addendum and Date Received: Addendum #’s / Received Date ____________________________________________________________________ Signature: Printed Name: Title: Company: Date:
Westshore Exterior Signage RFP RFI Question Responses
Capital and Construction Cuyahoga Community College
ADDEDENDUM #2 May 31, 2019
1. RFI Question: I see color LEDs on the SC1 and BN1 sign. RFI Response: Exterior Sign Type CS1 to be face lit with internal illumination from RGB LED light strips or modules. The color range of the all RGB LEDs should effectively illuminate Tri-C Teal color. The other 2 sets of channel letters to be halo back lit, white only.
2. RFI Question: How much “control” do you want? RFI Response: Customer controlled LED light color changes (Solid preset colors) without opening any access panels or setting controller pins. Remote control required.
3. RFI Question: DMX or basic? RFI Response: DMX 4. RFI Question: What is going to control it – computer or basic IR controller? RFI Response: Remote control 5. RFI Question: Where do they want it controlled from?
RFI Response: Remote control
6. RFI Question: It says “dimmable LEDs” on the drawing detail, but the technical information says non- dimming power supplies?
RFI Response: The DMX controller performs the diming function with either 12 volt or 24-volt dimmable or non-dimmable power supplies.
7. RFI Question: LED in the detail will not work well at all for assembly or for even illumination. Will you except alternates?
RFI Response: For the RGB LEDs specified MN believes the lighting and premanufactured strips will adequately illuminate the CS1 Logo sign. NO ALTERNATES, WORKING FULL SIZE SAMPLE REQUIRED BEFORE FINAL FABRICATION.
8. RFI Question: With all the illuminated letter sets, what are we mounting to? RFI Response: Blocking to support pin-mounted letters. Refer to wall sections in Appendix H for more information. Blocking to be located behind ACM exterior wall panels. Distance between blocking and Exterior ACM building skin approximately 3” +/- Field verify, as spacers will be required to prevent deformation of ACM face panels. Plywood to be provided behind metal panel system at signs CS1, BN1, and CN1. Information on metal panels provided below in response to separate RFI question. Bidders should review and determine if they choose to fasten to metal panel system(s) or to plywood behind the metal panels.
9. RFI Question: Is there blocking if needed? RFI Answer: See RFI question and answer above (#8)
10. RFI Question: Where will the power supplies be located? RFI Response: To be field verified, and coordinated with RFI #185 response, see appendix H.
Westshore Exterior Signage RFP RFI Question Responses
Capital and Construction Cuyahoga Community College
ADDEDENDUM #2 May 31, 2019
11. RFI Question: What are the wiring conditions: access, conduit? RFI Response: To be field verified, some interior gyp board removal will be required for sign BN1. See added Appendix H for more details.
12. RFI Question: FS1 Monument sign. Page EX19 shows it as double sided. Pages EX18 & EX20 show it as single sided. To build the monument this way, it can only be single sided, and there will be exposed leads from every letter protruding the back of the monument, prior to being grouped and run into the raceway, which will house the transformers.
RFI Response: Sign FS1 to be double sided. Increase width of masonry work (if needed) to provide internal cavity for wiring. Access panel at trailing end or behind teal logo panel for maintenance.
13. RFI Question: The sign shown in the photo on page EX 18 is not internally illuminated. The letters and logo, are just painted aluminum.
RFI Response: Sign Type FS1 to have face lit lettering and back lit logo panels on both sides.
14. RFI Question: The top view of FS2 – is inconsistent with notes below. FS2 cannot have an aluminum face with first and second surface painted graphics – do you mean double sided?
RFI Response: Yes, most are double sided.
15. RFI Question: Is aluminum an acceptable alternate to steel post? When we installed the original signs on the East side they were aluminum.
RFI Response: Our intent is to match the existing signs that are at Westshore.
16. RFI Question: Can the graphics be painted vinyl or do you want the signs frisket painted? The original signs were painted vinyl.
RFI Response: Painted vinyl or frisket painted lettering are acceptable.
17. RFI Question: What is the lighting type for each fixture? RFI Response: Exterior Sign Type CS1 to be face lit with internal illumination from RGB LED light strips or modules. The color range of the all RGB LEDs should effectively illuminate Tri-C Teal color. The other 2 sets of channel letters to be halo back lit, white only.
18. RFI Question: Please provide wall sections for all elevations for signs BN1, CN1 and CS1. RFI Response: See Appendix H
19. RFI Question: Please provide a materials spec sheet for the ACM fascia behind each sign type.
RFI Response: Panels at “Community Circle Symbol” (CS1) and “Building Name” (BN-1): Aluminum-composite material. Panels at “College Name” (CN-1): Centria IW-20A Horizontal Profile https://www.centria.com/products/rainscreens/concealed-fastener-panels/iw-series/iw-series-iw20a
Westshore Exterior Signage RFP RFI Question Responses
Capital and Construction Cuyahoga Community College
ADDEDENDUM #2 May 31, 2019
20. RFI Question: Please provide a specific brick type(s) for the monument sign. For bid purposes can we state that the Monarch Brick called out on drawing EX-19 is a standard, non-special order brick with no minimum order required from the brickyard?
RFI Response: Approved brick for Phase II project: Belden Brick, 4x4x16 Jewel Blend A, Grade: SW, Type FBX.
21. RFI Question: Please confirm that the project is prevailing wage. RFI Response: Yes, this project has a PLA is appendix G 22. RFI Question: Please confirm that zoning has been approved and that the sign contractor is only responsible for applying for building permits at this time. RFI Response: Yes, the college has received approval from Westlake Planning Commission. 23. RFI Question: Please confirm that the primary electrical service will be provided to all sign locations by others.
RFI Response: Power has been provided the general sign location (1 j-box behind CS1, 2 j boxes behind BN1, 1 j-box behind CN1) on the inside of the building. Exterior panels, sub-framing system and insulation will be removed on the exterior by others (and re-installed by others). Sign contractor responsible to extend power from these j-boxes to the signage, including removal and replacement of interior building finishes as required. All penetrations through the exterior sheathing and AVB (assumed separate penetrations for wiring each of the letters or sign parts) will need to be sealed with compatible sealant.
24. RFI Question: For the basis of bid purposes, can we state that the BN1 building sign letters are accessible by removing drywall as needed from the interior knee wall area?
RFI Response: Power has been provided along the 2nd floor line (2 locations) behind BN1 (in an approximate 8” space between the floor and the underside of a wall-mounted fin tube heating element. Bidders should assume extending power from these (2) j-boxes to power the sign letters, including removal and replacement of drywall as needed.
25. RFI Question: Please confirm what items are due at the time of bid. RFI Response: Reference RFP section 2 and 4 for requirements.
Westshore Exterior Signage RFP RFI Question Responses
Capital and Construction Cuyahoga Community College
ADDEDENDUM #2 May 31, 2019
26. RFI Question: Please clarify item 9 in scope of work. Whom is responsible for providing the primary power and sign on/off controls?
RFI Response: Include all light control devices; reference RFI 185 for work provided by electrician. Electric to be stubbed out at all sign locations by others.
27. RFI Question: Please clarify item 10 in scope of work. It is only assumed that in wall blocking may be utilized as a method of sign attachment. Items 11 and 12 are related to how the sign is attached. For bid purposes can we state whether blocking is required or not and whom is to provide it? Can the architect provide a pre-approved method of sign attachment so that all are bidding equally?
RFI Response: Some blocking will be in place at sign locations, if additional blocking is needed it will be coordinated in the field. See RFI response #8
28. RFI Question: Regarding the ground sign. Is the sign single or double sided? Please confirm that the sign is to be installed in “Normal Soil Conditions” and that no concrete or asphalt cutting and or patching is required for sign installation. Please confirm that the primary electric and sign on/off controls to the ground sign are to be provided by others.
RFI Response: Electric to be stubbed out at all sign locations by others. Signage vendor to include photo cell on/off control. Assume “Normal Soil Conditions”.
29. RFI Question: How will the sign mounting effect the vapor barrier?
RFI Response: All penetrations through the AVB will need to be sealed with a compatible sealant by the sign installer. Exterior panels, sub-framing and insulation will be removed by others (and re-installed by others) to help facilitate this requirement.
30. RFI Question: Can a drawing be supplied that shows signage location elevations in relation to the floor elevations
RFI Response: See Appendix H 31. RFI Question: Can the signage be flush mounted instead of 1” reveal?
RFI Response: Type CS1 Channeled logo can be flush mounted to the building as it is face lit. 32. RFI Question: Will the Runtal units effect access to the power, what happens if the boxes go bad?
RFI Response: Sign vendor to locate access panel on inside wall at gap between Runtal units or at top or end for access to Sign Type BN1 power supplies. Power for BN-1 is located below the Runtal (fin tube) heaters at 2 locations. Sign installers should assume power is fed from these boxes to the lettering within the available wall space (approx 8”) below the runtal units.
33. RFI Question: Confirm there is a separate signage circuit for the electrical connections.
RFI Response: Electrical locations have been coordinated.
REQUEST FOR INFORMATION
1098. : TRI-C WESTSHORE PHASE 2
RFI # 185
Date: 09/28/2018
To: Samuel Marcum From: Mary Ianiro
Moody Nolan Architects Donley's, Inc.
1621 Euclid ave., Suite 1150 5430 Warner Rd.
Cleveland, OH 44115 Cleveland, OH 44125
Phone: 216-432-0696 Phone: 216-524-6800
Fax: Fax: 216-642-3216
Email: [email protected] Email: [email protected]
CC:
Subject: Layout Dimensions/Rough-in Coordination Needed Status: New
Drawing #: Spec Sect#: Submittal #:
Addendum: Schedule #: Response Due: 10/02/2018
Potential Schedule &/or Cost Impacts:
Schedule Impact: days Cost Impact: $
Information Requested: Dated Required: 10/02/2018
Reference attached drawings.
1. Please provide rough-in coordination for the power for the signage as indicated by coded note 4.
2. Please provide layout dimensions for the exterior power pedestals and the ADA pedestal at the entrance.
Additional Information:
Submitted By:
Mary Ianiro
Response:
CLEMENS ROAD 60'
INTERSTATE 90
CLEMENS ROAD 60'
INTERSTATE 90
J
J
J
J
J
J J
J
J
J
J
J
SLP4HP21:7
SLP4HP21:7
SLP4HP21:7
SLP42HP21:9
SLP42HP21:9
SLP42HP21:11
SLP42HP21:11
SLP4HP21:11
SLP4HP21:9
SLP3HP21:7
SLP3HP21:9
SLP3HP21:7
SLP3LHP21:5
N48a
SLP3LHP21:5
N48a
SLP3LHP21:5N48a
1
EXISTING IN GROUND MANHOLE (REX)
2
SLP3LHP21:5N48a
SLFHP21:1N48b
SLFHP21:1
N48b
3
4
4
4
5
5
5
5
5
5
LP21:25
LP21:25
LP21:23LP21:21
LP21:21
LP21:23
HP21:13N48c
HP21:3N48d
HP21:3N48d
HP21:3N48d
ALTERNATE #1.RELOCATE STANCHIONS ABOUT 100' WEST AND DELETE LUMINAIRES.
6 6
SLP4HP21:7
SLP42HP21:9
SLP42HP21:11
SLP4HP21:7
SLP3LHP21:5N48a
SLP3LHP21:5N48a
SLP3LHP21:5N48a
1
SLP3LHP21:5N48a
SLP3LHP21:5N48a
HP21:3N48d
4
4
HP21:3N48d
7
7
D
C A B
60'30'0
SCALE: 1" = 30'-0"
©
EEEE----61663616636166361663
OOOOIIIIHHHHOOOO
FFFFOOOOEEEETTTTAAAATTTT
SSSS
SSSSIIIIEEEERRRR
GGGG RRRREEEETTTTEEEEDDDD
BRIAN BRIAN BRIAN BRIAN
J.J.J.J.
DAVIDDAVIDDAVIDDAVID
RRRROOOOFFFF
SSSSSSSSIIII
EEEENNNNIIII
EEEEAAAAOOOO
PPPP
LLLLNNNNGGGG
EEEE
NNNN
EEEERRRR
© 2
016
Moo
dy/N
ola
n In
c.
DRAWING TITLE:
300 Spruce SteetSuite 300Columbus, Ohio 43215
Phone: (614) 461-4664Fax: (614) 280-8881www.moodynolan.com
DRAWN BY: CHECKED BY:
KEYNOTE LEGENDKEYNOTE LEGENDKEYNOTE LEGENDKEYNOTE LEGEND
KEYPLANKEYPLANKEYPLANKEYPLAN
16
02
22_
ME
PT
_R
17
_de
tach
ed.r
vt
4/1
7/2
01
8 2
:13:1
2 P
M
16213.01
04/20/18
CONFORMED SET
E-100
AL KHM
SITE ELECTRICAL PLAN
Tri-C Westshore Phase 2 - HCSBuilding Renovation
CUYAHOGA COMMUNITY
COLLEGE
31001 Clemens RoadWestlake, Ohio 44145
PLAN NOTES1 PROVIDE HANDHOLE TO MATCH EXISTING. EXTEND COUNDUIT
FROM THE EXISTING HANDHOLE TO BE REMOVED, TO THE NEWHANDHOLE. REFER TO HANDHOLE DETAIL DRAWING ON SHEETE-604 FOR MORE DETAILS.
2 PROVIDE (3) 4" DUCTS CONCRETE ENCASED. REFER TO THEDETAILS ON SHEET E-604.
3 PROVIDE HANDHOLE TO ACCOMODATE POWER FOR THE SIGNAND FOR THE LUMINAIRES THAT ARE GRADE MOUNTED.
4 JUNCTION BOX FOR THE SIGN. COORDINATE EXACT LOCATIONAND HEIGHT WITH ARCHITECTURAL DRAWINGS.
5 JUNCTION BOX 120V, 0.2KW, 1Ø FOR THE BLUE LIGHTSTANCHION, AND CCTV CAMERA. PROVIDE 2#10, 1#10GND IN1"CONDUIT. CIRCUIT IS SHOWN ON THE DRAWING.COORDINATE LOCATION WITH TC AND CIVIL SITE DRAWINGS.REFER TO TECHNOLOGY DRAWINGS FOR MORE DETAILS.
6 THE FRONT OF LUMINAIRES SHALL BE 3' AWAY FROM THEFRONT OF THE SIGN, ON CENTER WITH THE SIGN. COORDINATEEXACT LOCATION WITH ARCHITECT, AND SIGN SUPPLIER PRIORTO ROUGH-IN.
7 PROVIDE 24" SWEEP FOR ALL BENDS AND OFFSETS.
LUMINAIRE TYPES 'SLP3', 'SLP4',
LUMINAIRE TYPE SLP3L
1. ALL SITE LIGHTING SHALL USE #10AWG WIRE SIZE
GENERAL
# DATE CHANGE DESCRIPTION
04/27/18
24'
Wetlands to beconserved
4x4" conduits inductbank approx 3' deep
48"x48" in-ground pull box perteledata site drawing T-002
15' 1"
60'
EXTERIOR SIGNAGE PRESENTATION • MEETING 02 • SEPTEMBER 20, 2018
WEST ELEVATION
1/16” = 1’-0”
BL-1 BUILDING LOGOSCALE: 1/4” = 1’-0”
BN-2 BUILDING NAMESCALE: 3/16” = 1’-0”
WESTSHORE LIBERAL ARTS BUILDING
WESTSHORE LIBERAL ARTS BUILDING
12’-0”
50’-4”
12’-0”
2’-0”
2” THICK HALO-LIT INTERNALLY ILLUMINATED ALUMINUM SIGN. FACE AND RETURNS TO BE PAINTED SILVER.
TO BE PIN-MOUNTED TO BUILDING.
OVERALL SIZE: 100 S.F. +/-
FONT: ITC FRANKLIN GOTHIC STD MEDIUM
Note: Signs shown are preliminary. Text to be reviewed and approved by owner.
5” THICK HALO-LIT INTERNALLY ILLUMINATED ALUMINUM SIGN. FACE AND RETURNS TO BE PAINTED SILVER.
TO BE PIN-MOUNTED TO BUILDING.
OVERALL SIZE: 144 S.F. +/-
EXTERIOR SIGNAGE PRESENTATION • MEETING 02 • SEPTEMBER 20, 2018
SOUTH ELEVATION
BN-2 - BUILDING NAME SIGNSCALE: 1/4” = 1’-0”
CUYAHOGACOMMUNITY
COLLEGE
CUYAHOGACOMMUNITY
COLLEGE
1/16” = 1’-0”
CUYAHOGACOMMUNITY
COLLEGE7’-2”
15’-8”+/-
2’-0”CAP. HT.
3” THICK INTERNALLY ILLUMINATED ALUMINUM CHANNEL LETTERS. FACE-LIT LETTERS WITH RETURNS PAINTED WHITE. LIGHTS TO BE LED AND DIMMABLE.
TO BE PIN-MOUNTED TO BUILDING.
OVERALL SIZE: 112 S.F. +/-
FONT: ITC FRANKLIN GOTHIC STD MEDIUM
Note: Signs shown are preliminary. Text to be reviewed and approved by owner.
EXTERIOR SIGNAGE DOCUMENT
Tri-C Westshore CampusPhase II - New Building & Renovation
ISSUE SET: 05.20.2019ADDENDUM SET: 05.30.2019
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-2
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
10400 SIGNAGE SPECIFICATIONS
Ohio.
MAY 2019MAY 2019
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-3
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
MAY 2019MAY 2019
10400 SIGNAGE SPECIFICATIONS
BN1 Building Name Sign - Example Letter for quality and finish approvalCN1 College Name Sign - Example Letter for quality and finish approvalCS1 Community Circle Symbol - Example Letter for quality and finish approval
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-4
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
MAY 2019MAY 2019
10400 SIGNAGE SPECIFICATIONS
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-5
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
State of Ohio
MAY 2019MAY 2019
10400 SIGNAGE SPECIFICATIONS
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-6
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
MAY 2019MAY 2019
10400 SIGNAGE SPECIFICATIONS
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-7
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
MAY 2019MAY 2019
10400 SIGNAGE SPECIFICATIONS
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-8
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
MAY 2019MAY 2019
10400 SIGNAGE SPECIFICATIONS
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-9
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
MAY 2019MAY 2019
10400 SIGNAGE SPECIFICATIONS
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-10
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
LOGO, COLOR & FINISHES
BRAND ELEMENTS
DARK GREYPMS 432C
PAINTBENJAMIN MOORESTONECUTTER 2135-20
TEAL LOGO BLACK LOGO COMMUNITY CIRCLE SYMBOL COLLEGE SEAL
TRI-C TURQUOISEPMS 321C
PAINTBENJAMIN MOORE ARUBA BLUE 2048-30
LIGHT TURQUOISEPMS 324C
PAINTBENJAMIN MOORE JAMAICAN AQUA 2048-60
WHITE PAINT
BENJAMIN MOORE WINTER SNOW 0C-63
WHITE VINYL
GERBER A6 OPAQUE MATTE WHITE A6002-O
PAINT TO MATCH EXTERIOR BUILDING PANEL
ARCHITECT TO PROVIDE BUILDING MATERIAL SAMPLE TO FABRICATOR. FABRICATOR TO PROVIDE CUSTOM-PAINTED SAMPLES TO ARCHITECT FOR APPROVAL.
SILVER PAINT
FABRICATOR TO PROVIDE CUSTOM-PAINTED SAMPLES TO ARCHITECT FOR APPROVAL.
PROJECT PALETTE
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-11
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
EXTERIOR SIGNAGE LOCATION PLAN
1
FS1
CS1
BN1
CN1
FS2.1
FS2.3
FS2.2
FS2.4 FS2.5FS2.6
FS2.7
FS2.8
FS3.4
FS3.7FS3.8
FS3.5
FS3.6
FS3.3
FS3.1
FS2.6 FS2.7
FS3.2
EXTERIOR SIGNAGE LOCATION PLAN
CLEMENS ROADCLEMENS ROAD
MAIN ENTRY
SECONDARY ENTRY
NEXTERIOR SIGNAGE LISTTYPE NAME
BN1 Building Name SignNEW SIGN
NEW MESSAGE FOR EXISTING SIGN
CN1 College Name Sign
CS1 Community Circle Symbol
FS1 Monument Sign
FS2 Vehicular Directional Sign
FS3 Single-Post Sign
SIGN TAG
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-12
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
SOUTHWEST RENDERING
CS1COMMUNITY CIRCLE SYMBOL
BN1BUILDING NAME
CN1COLLEGE NAME
EXISTING EXTERIOR SIGNAGEPHASE TWO EXTERIOR SIGNAGE
VIEW FROM
SOUTHWEST
SECONDARY ENTRY
MAIN ENTRY
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-13
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
WEST RENDERING
VIEW FROM
WEST
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-14
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
WEST RENDERING
NIGHT VIEW FROM
WEST
WHITE LIGHT
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-15
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
WEST ELEVATION
1 ELEVATION - OVERALL WESTSCALE: 3/32” = 1’-0”
LIBERAL ARTS & TECHNOLOGY
ALIGN TOP OF SIGN WITH TOP OF INSULATED COMPOSITE BACK-UP PANELS & LOUVERS
INSULATED COMPOSITE BACK-UP PANELS & LOUVERS
ALIGN SIGN WITH RIGHT EDGE OF BUILDING WINDOWS
SEE PARTIAL SECTION ON NEXT PAGE FOR ADDITIONAL DETAILS
1’-11”
EQ.
EQ.
10’-1/2”EQ.EQ.
CS1 - COMMUNITY CIRCLE SYMBOLOVERALL SIZE: 99 S.F.
BN1 - BUILDING NAME SIGNOVERALL SIZE: 74 S.F.
13’-0”+/-ABOVEGRADE
49’-3”+/-ABOVEGRADE
MAIN ENTRY
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-16
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
CS1 & BN1 EXTERIOR SIGNS
1
3 CS1 - COMMUNITY CIRCLE SYMBOLSCALE: 1/4” = 1’-0”
2 BN1 - BUILDING NAME SIGNSCALE: 3/16” = 1’-0”
1 BN1 - PARTIAL SECTIONNot to scale, Field verify all dimensions
38’-8”+/-
1’-11” LIBERAL ARTS & TECHNOLOGY
5” THICK, INTERNALLY ILLUMINATED FACE-LIT ALUMINUM SIGN. FACE TO BE TRANSLUCENT ACRYLIC LENS WITH FIRST SURFACE DAY-NIGHT PERFORATED VINYL PAINTED TO MATCH EXTERIOR BUILDING TILE. RETURNS TO BE PAINTED TO MATCH EXTERIOR BUILDING TILE. LIGHTING TO BE LLI RGBW 5.8W LED TAPE-IP68 COLOR-CHANGING, DIMMABLE LEDS.
TO BE PIN-MOUNTED 1” FROM BUILDING FACE.
FABRICATOR TO PROVIDE PAINT SAMPLES TO ARCHITECT FOR FINAL APPROVAL.
OVERALL SIZE: 99 S.F.
CS1 - LIGHTING SPECIFICATIONFABRICATOR TO COORDINATE WITH LLI ARCHITECTURAL LIGHTING REPRESENTATIVE, SHANNON FRY ([email protected]) ON LIGHTING SPECIFICATION.
10’-1/2”
9’-10 1/2”
3” THICK INTERNALLY ILLUMINATED HALO- LIT ALUMINUM SIGN.FACE AND RETURNS TO BE PAINTED SILVER.
TO BE PIN-MOUNTED 2” FROM BUILDING FACE.
OVERALL SIZE: 74 S.F.
FONT: ITC FRANKLIN GOTHIC STD MEDIUMGYP BOARD ON INTERIOR SIDE OF KNEEWALL
TO BE REMOVED SPARINGLY TO WIRE SIGN AND CONNECT POWER
SIGN CONTRACTOR TO BE RESPONSIBLE FOR REPAIRING AND REPAINTING GYPBOARD IN THIS AREA
MAINTENANCE ACCESS THROUGH SURFACE MOUNTED ACCESS PANELSPAINT ACCESS PANELS TO MATCH WALL COLORS
ACCESS PANELS AND FINAL PAINTING BY SIGNAGE CONTRACTOR
SPECIFIER
PROJECT
DATE
RGBW 5.8W LED TAPE - IP68
Technical Information
Wattage 5.8W per foot
IP Rating IP68 - wet locations. Protected against temporary submersion, limited protection against harsh environments.
Output RGB30K RGB60K
RGB 289 lm/ftRed (620-625nm) 22 lm/ftGreen (520-525nm) 62 lm/ftBlue (465-470nm) 14 lm/ft 3000K 180 lm/ft
RGB 305 lm/ftRed (620-625nm) 22 lm/ftGreen (520-525nm) 62 lm/ftBlue (465-470nm) 14 lm/ft 6000K 238 lm/ft
Input Voltage 24VDC
Cut Length Every 4”, or every 6 LEDs
Maximum Run 32 feet
Dimensions 0.54” W x 0.21” H (13.7mm x 5.3mm)
Adhesive Backing Yes - VHB
Lifespan 50,000 hrs
Warranty 3 year limited
Power Supply Compatible with all 24VDC non-dimming power supplies -- see power supply section of website
Recommended applications:
Shallow coves
Under-cabinet
Back-lit graphics
Accent lighting
Sign lighting
Part Number Builder / Ordering Guide
REV 05.18
SERIES
LLI-LCCW5.8W-68
COLOR LENGTHVOLTAGE
Example part number: LLI-LCCW5.8W-68-RGB30K-24V-96in
1555 Barclay Blvd. Buffalo Grove, IL 60089
Mounting options:
Architectural extrusions and other mounting solutions are
available
(sold separately).
24VXXX - custom length (in)
**If a custom, pre-assembled layout is desired, please use the layout guide on page 3 to specify a layout code**
Connector options:
Not compatible with connectors – must be fabricated to
specification by factory. Use Layout Guide on page 3 to specify
factory-assembled connections.
RGB30KRGB60K
0.54”13.7mm
3
IP68 - solid silicone(profile view)
GLASS
KNEE WALL
RGB CONTROLLER RECESSED J-BOX
INSIDE FLOOR
POWER SUPPLY CLUSTER INSIDE
WALL DIMENSIONAL LETTERING-HALO RGB LED ILLUMINATIONW/ REMOTE CONTROL
LOW VOLTAGE POWER PENETRATION-1 REQUIRED AT EACH LETTER TOP
THREADED MOUNTING RODS
24 volt
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-17
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
CN1 - COLLEGE NAME SIGN - SOUTH ELEVATION
1 OVERALL - SOUTH ELEVATION SCALE: 3/32” = 1’-0”
CUYAHOGACOMMUNITY
COLLEGE
CUYAHOGACOMMUNITY
COLLEGE
1’-6”
1’-6”
38-0”+/- ABOVE GRADE
CN-1 - CAMPUS BRANCH SIGNOVERALL SIZE: 97 S.F. +/-
2 CN1 - COLLEGE NAME SIGNSCALE: 1/4” = 1’-0”
6’-8”
14’-6 1/2”+/-
1’-10”CAP. HT.
3” THICK INTERNALLY ILLUMINATED FACE- LIT ALUMINIUM SIGN. FACE AND RETURNS TO BE PAINTED WHITE.
TO BE PIN-MOUNTED 1” FROM BUILDING FACE.
OVERALL SIZE: 97 S.F. +/-
FONT: ITC FRANKLIN GOTHIC STD MEDIUM
SECONDARY ENTRY
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-18
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
FS1 - MONUMENT SIGN
1 FS1 - MONUMENT SIGN - PERSPECTIVESCALE: N.T.S.
2 FS1 - MONUMENT SIGN - ELEVATIONSCALE: 1/4” = 1’-0”
3 FS1 - MONUMENT SIGN - ELEVATIONSCALE: 1/4” = 1’-0”
8” PAINTED WHITE ALUMINUM, INTERNALLY ILLUMINATED LETTERS
6” PAINTED WHITE ALUMINUM, INTERNALLY ILLUMINATED LETTERS
EXISTING SIGN
NOTE TO FABRICATOR:FABRICATOR TO SURVEY EXISTING SITE SIGNAGE. THIS SIGN TO MATCH EXISTING FREESTANDING SIGN ON TRI-C WESTSHORE CAMPUS. SIGN RENDERINGS, PLAN, ELEVATIONS, SECTIONS DRAWN BY BURT, HILL ARCHITECTS AND PROVIDED TO MOODY NOLAN.
FABRICATOR TO FIELD-VERIFY LETTER HEIGHTS AND MOUNTING LOCATIONS TO MATCH EXACTLY WHEN CONSTRUCTING SIGN.
FS1 -NEW SIGN TO BE DOUBLE SIDED-BRICK TO MATCH BRICK USED IN NEW TRI-C SLS BUILDING CONSTRUCTION
1
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-19
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
FS1 - MONUMENT SIGN
SIGN BASE0' - 0"
8" LETTERING
MONARCH BRICK 'B'
4" PRECAST CAP
MONARCH BRICK 'A'
2'-2" W X 2'-6" HRECESSED INTERNALLY
ILLUMINATED LOGO
EQ EQ
9' - 0"
4' - 11"
6" LETTERING
4" PRECEST CAP
2' - 1"
1SK-03bSK-03b
2SK-03bSK-03b
1SK-03bSK-03b
2SK-03bSK-03b
1' - 4
"
3' - 8" 9' - 8"
1' - 0
"
2"
SIGN BASE0' - 0"
4' - 0
"4 1
/2"
1' - 1"
1/2"
PRECAST CAP
MONARCH BRICK(4"x4"x16")ALUMINUM SURFACEMOUNTED LETTERINGPAINTED WHITE
4" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
8" MIN
APPROX. GRADE
SIGN BASE0' - 0"
PRECAST CAP
MONARCH BRICK(4"x4"x16")
CONT. STRUCTURALSTEEL RELIEF ANGLE
8" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
APPROX. GRADE
1' - 5"
1/2"
4' - 8
"4 1
/2"8" MIN
2'-2"W x 2'-6"H RECESSEDINTERNALLY LED ILLUMINATEDLOGO SIGN CABINET
1/4" = 1'-0"ELEVATION
1/4" = 1'-0"PLAN
3/4" = 1'-0"SK-03b
1 SECTION 3/4" = 1'-0"SK-03b
2 SECTION
SIGN BASE0' - 0"
8" LETTERING
MONARCH BRICK 'B'
4" PRECAST CAP
MONARCH BRICK 'A'
2'-2" W X 2'-6" HRECESSED INTERNALLY
ILLUMINATED LOGO
EQ EQ
9' - 0"
4' - 11"
6" LETTERING
4" PRECEST CAP
2' - 1"
1SK-03bSK-03b
2SK-03bSK-03b
1SK-03bSK-03b
2SK-03bSK-03b
1' - 4
"
3' - 8" 9' - 8"
1' - 0
"
2"
SIGN BASE0' - 0"
4' - 0
"4 1
/2"
1' - 1"
1/2"
PRECAST CAP
MONARCH BRICK(4"x4"x16")ALUMINUM SURFACEMOUNTED LETTERINGPAINTED WHITE
4" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
8" MIN
APPROX. GRADE
SIGN BASE0' - 0"
PRECAST CAP
MONARCH BRICK(4"x4"x16")
CONT. STRUCTURALSTEEL RELIEF ANGLE
8" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
APPROX. GRADE
1' - 5"
1/2"
4' - 8
"4 1
/2"8" MIN
2'-2"W x 2'-6"H RECESSEDINTERNALLY LED ILLUMINATEDLOGO SIGN CABINET
1/4" = 1'-0"ELEVATION
1/4" = 1'-0"PLAN
3/4" = 1'-0"SK-03b
1 SECTION 3/4" = 1'-0"SK-03b
2 SECTION
SIGN BASE0' - 0"
8" LETTERING
MONARCH BRICK 'B'
4" PRECAST CAP
MONARCH BRICK 'A'
2'-2" W X 2'-6" HRECESSED INTERNALLY
ILLUMINATED LOGO
EQ EQ
9' - 0"
4' - 11"
6" LETTERING
4" PRECEST CAP
2' - 1"
1SK-03bSK-03b
2SK-03bSK-03b
1SK-03bSK-03b
2SK-03bSK-03b
1' - 4
"
3' - 8" 9' - 8"
1' - 0
"
2"
SIGN BASE0' - 0"
4' - 0
"4 1
/2"
1' - 1"
1/2"
PRECAST CAP
MONARCH BRICK(4"x4"x16")ALUMINUM SURFACEMOUNTED LETTERINGPAINTED WHITE
4" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
8" MIN
APPROX. GRADE
SIGN BASE0' - 0"
PRECAST CAP
MONARCH BRICK(4"x4"x16")
CONT. STRUCTURALSTEEL RELIEF ANGLE
8" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
APPROX. GRADE
1' - 5"
1/2"
4' - 8
"4 1
/2"8" MIN
2'-2"W x 2'-6"H RECESSEDINTERNALLY LED ILLUMINATEDLOGO SIGN CABINET
1/4" = 1'-0"ELEVATION
1/4" = 1'-0"PLAN
3/4" = 1'-0"SK-03b
1 SECTION 3/4" = 1'-0"SK-03b
2 SECTION
SIGN BASE0' - 0"
8" LETTERING
MONARCH BRICK 'B'
4" PRECAST CAP
MONARCH BRICK 'A'
2'-2" W X 2'-6" HRECESSED INTERNALLY
ILLUMINATED LOGO
EQ EQ
9' - 0"
4' - 11"
6" LETTERING
4" PRECEST CAP
2' - 1"
1SK-03bSK-03b
2SK-03bSK-03b
1SK-03bSK-03b
2SK-03bSK-03b
1' - 4
"
3' - 8" 9' - 8"
1' - 0
"
2"
SIGN BASE0' - 0"
4' - 0
"4 1
/2"
1' - 1"
1/2"
PRECAST CAP
MONARCH BRICK(4"x4"x16")ALUMINUM SURFACEMOUNTED LETTERINGPAINTED WHITE
4" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
8" MIN
APPROX. GRADE
SIGN BASE0' - 0"
PRECAST CAP
MONARCH BRICK(4"x4"x16")
CONT. STRUCTURALSTEEL RELIEF ANGLE
8" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
APPROX. GRADE
1' - 5"
1/2"
4' - 8
"4 1
/2"8" MIN
2'-2"W x 2'-6"H RECESSEDINTERNALLY LED ILLUMINATEDLOGO SIGN CABINET
1/4" = 1'-0"ELEVATION
1/4" = 1'-0"PLAN
3/4" = 1'-0"SK-03b
1 SECTION 3/4" = 1'-0"SK-03b
2 SECTION
1 FS1 - MONUMENT SIGN - PLANSCALE: 1/4” = 1’-0” 3 FS1 - MONUMENT SIGN - SECTION
SCALE: 3/4” = 1’-0” 4 FS1 - MONUMENT SIGN - SECTIONSCALE: 3/4” = 1’-0”
2 FS1 - MONUMENT SIGN - ELEVATION (TYP)SCALE: 1/4” = 1’-0”
3
EX-19
3
EX-19
4
EX-19
4
EX-19
8” PAINTED WHITE ALUMINUM, INTERNALLY ILLUMINATED LETTERS
6” PAINTED WHITE ALUMINUM, INTERNALLY ILLUMINATED LETTERS
WHITE-PAINTED ALUMINUM LETTERS TO BE INTERNALLY ILLUMINATED (TYP)
NOTE TO FABRICATOR:FABRICATOR TO SURVEY EXISTING SITE SIGNAGE. THIS SIGN TO MATCH EXISTING FREESTANDING SIGN ON TRI-C WESTSHORE CAMPUS. SIGN RENDERINGS, PLAN, ELEVATIONS, SECTIONS DRAWN BY BURT, HILL ARCHITECTS AND PROVIDED TO MOODY NOLAN.
FABRICATOR TO FIELD-VERIFY LETTER HEIGHTS AND MOUNTING LOCATIONS TO MATCH EXACTLY WHEN CONSTRUCTING SIGN.
FS1 -NEW SIGN TO BE DOUBLE SIDED-BRICK TO MATCH BRICK USED IN NEW TRI-C SLS BUILDING CONSTRUCTION-INCREASE WIDTH OF MASONRY STRUCTURE TO ACCOMODATE INTERNAL CAVITY FOR SECONDARY WIRING TO PROVIDE ILLUMINATED COPY ON BOTH SIDES OF SIGN FS1.
1
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-20
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
FS1 - MONUMENT SIGNSIGN BASE
0' - 0"
8" LETTERING
MONARCH BRICK 'B'
4" PRECAST CAP
MONARCH BRICK 'A'
2'-2" W X 2'-6" HRECESSED INTERNALLY
ILLUMINATED LOGO
EQ EQ
9' - 0"
4' - 11"
6" LETTERING
4" PRECEST CAP
2' - 1"
1SK-03bSK-03b
2SK-03bSK-03b
1SK-03bSK-03b
2SK-03bSK-03b
1' - 4
"
3' - 8" 9' - 8"
1' - 0
"
2"
SIGN BASE0' - 0"
4' - 0
"4 1
/2"
1' - 1"
1/2"
PRECAST CAP
MONARCH BRICK(4"x4"x16")ALUMINUM SURFACEMOUNTED LETTERINGPAINTED WHITE
4" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
8" MIN
APPROX. GRADE
SIGN BASE0' - 0"
PRECAST CAP
MONARCH BRICK(4"x4"x16")
CONT. STRUCTURALSTEEL RELIEF ANGLE
8" CMU
HORIZONTAL JOINTREINFORCING 16" O.C.
REINFORCED CONCRETEFOUNDATION
APPROX. GRADE
1' - 5"
1/2"
4' - 8
"4 1
/2"8" MIN
2'-2"W x 2'-6"H RECESSEDINTERNALLY LED ILLUMINATEDLOGO SIGN CABINET
1/4" = 1'-0"ELEVATION
1/4" = 1'-0"PLAN
3/4" = 1'-0"SK-03b
1 SECTION 3/4" = 1'-0"SK-03b
2 SECTION
FRONT - TYPICAL SIDE -TYPICAL
1 FS1 - MONUMENT SIGN - ELEVATIONSCALE: 3/4” = 1’-0”
2 FS1 - FACE-LIT LETTER DETAILSCALE: N.T.S.
2” THICK FACE-LIT, INTERNALLY ILLUMINATED ALUMINUM LETTERS. SIDES AND TRIM CAPS TO BE PAINTED WHITE.
LETTERS TO BE PIN-MOUNTED TO SIGN WITH ALL WIRING HIDDEN IN SIGN CABINET.
2’-2” (W) X 2’-6” (H) RECESSED INTERNALLY ILLUMINATED LOGO TO MATCH EXISTING SIGN STYLE
MITERED FRAME PAINTED BLUE TO MATCH EXISTING SIGN
8”
3”
6”
1’-5”+/-
9’-0”+/-
2’-2”+/-
2’-6”+/-
6”
3”
NOTE TO FABRICATOR:FABRICATOR TO SURVEY EXISTING SITE SIGNAGE. THIS SIGN TO MATCH EXISTING FREESTANDING SIGN ON TRI-C WESTSHORE CAMPUS. SIGN RENDERINGS, PLAN, ELEVATIONS, SECTIONS DRAWN BY BURT, HILL ARCHITECTS AND PROVIDED TO MOODY NOLAN.
FABRICATOR TO FIELD-VERIFY LETTER HEIGHTS AND MOUNTING LOCATIONS TO MATCH EXACTLY WHEN CONSTRUCTING SIGN.
EXISTING SIGN
C L
C L
ALIGN SIGN TOP TO TOP OF ADJACENT BRICK
FS1 -NEW SIGN TO BE DOUBLE SIDED-BRICK TO MATCH BRICK USED IN NEW TRI-C SLS BUILDING CONSTRUCTION-INCREASE WIDTH OF MASONRY STRUCTURE TO ACCOMODATE INTERNAL CAVITY FOR SECONDARY WIRING TO PROVIDE ILLUMINATED COPY ON BOTH SIDES OF SIGN FS1.-INSTALL TOP CAP AFTER WIRING IS COMPLETE
1
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-21
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
FS2 - VEHICULAR DIRECTIONAL SIGN
1 FS2 - VEHICLE DIRECTIONAL SIGNSCALE: 3/4” = 1’-0”
DARK GREY PMS 432CPAINTED BENJAMIN MOORE STONECUTTER 2135-20
ALUMINUM SIGN FACE WITH FIRST SURFACE PAINTED AND CUT VINYL OR MASKED AND
FRISKET PAINTED DIRECTIONAL COPY
SIGN POST TO BE CAPPED AND CAP TO BE PAINTED TO MATCH POLE
3” PAINTED ROUND STEEL OR ALUMINUM POST
POURED CONCRETE FOOTER; FABRICATOR TO DETERMINE APPROPRIATE DIMENSIONS PER SITE CONDITIONS
DARK GREY PMS 432CPAINTED BENJAMIN MOORE STONECUTTER 2135-20
TRI-C TURQUOISE PMS 321CPAINTED BENJAMIN MOORE ARUBA BLUE 2048-30, PAINTED AND CUT VINYL OR FRISKET MASKED PAINTED RULE LINES
TRI-C TURQUOISE PMS 321CPAINTED BENJAMIN MOORE ARUBA BLUE 2048-30
LIGHT TURQUOISE PMS 324CPAINTED BENJAMIN MOORE JAMAICAN AQUA 2048-60 PAINTED VINYL OR FRISKET MASKED PAINTED COPY
WHITE PAINT OR PAINTED VINYLPAINTED BENJAMIN MOORE WINTER SNOW 0C-63
NOTE TO FABRICATOR:FABRICATOR TO SURVEY EXISTING SITE SIGNAGE. THIS SIGN TO MATCH EXISTING FREESTANDING SIGN ON TRI-C WESTSHORE CAMPUS. SIGN RENDERINGS, PLAN, ELEVATIONS, SECTIONS DRAWN BY STUDIO GRAPHIQUE ARCHITECTS AND PROVIDED TO MOODY NOLAN.
EXISTING SIGNS
NOTE: FABRICATOR TO COORDINATE FINAL MESSAGING WITH OWNER.
1
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-22
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
FS2 - VEHICULAR DIRECTIONAL SIGN
Student DropoffSHCS Main Entrance
Parking
Student DropoffSLT Main Entrance
Delivery
Student DropoffSLT Main Entrance
Student DropoffSHCS Main Entrance
Parking
Delivery
Student DropoffSLT Main Entrance
Student DropoffSHCS Main Entrance
Student DropoffSLT Main Entrance
Parking
Delivery
Faculty Parking
Student DropoffSHCS Main Entrance
Faculty Parking
Student DropoffSLT Main Entrance
1 FS2.1 - SIDE A SCALE: 1/2” = 1’-0”
5 FS2.3 - SIDE A SCALE: 1/2” = 1’-0”
2 FS2.1 - SIDE B SCALE: 1/2” = 1’-0”
6 FS2.3 - SIDE B SCALE: 1/2” = 1’-0”
3 FS2.2 - SIDE A SCALE: 1/2” = 1’-0”
7 FS2.4 - SIDE A SCALE: 1/2” = 1’-0”
4 FS2.2 - SIDE B SCALE: 1/2” = 1’-0”
8 FS2.4 - SIDE B SCALE: 1/2” = 1’-0”
NOTE: FABRICATOR TO COORDINATE FINAL MESSAGING WITH OWNER.
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-23
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
FS2 - VEHICULAR DIRECTIONAL SIGN
Student DropoffSHCS Main Entrance
Delivery
Faculty Parking
Student DropoffSLT Main Entrance
Delivery
Faculty Parking
Faculty Parking
Student DropoffSHCS Main Entrance
Student DropoffSLT Main Entrance
Faculty Parking
Delivery
Delivery
Parking
Student DropoffSLT Main Entrance
Parking
Student DropoffSHCS Main Entrance
Student DropoffSLT Main Entrance
Student DropoffSHCS Main Entrance
Parking
1 FS2.5 - SIDE A SCALE: 1/2” = 1’-0”
5 FS2.7 - SIDE A SCALE: 1/2” = 1’-0”
2 FS2.5 - SIDE B SCALE: 1/2” = 1’-0”
6 FS2.7 - SIDE B SCALE: 1/2” = 1’-0”
3 FS2.6 - SIDE A SCALE: 1/2” = 1’-0”
7 FS2.8 - SIDE A SCALE: 1/2” = 1’-0”
4 FS2.6 - SIDE B SCALE: 1/2” = 1’-0”
8 FS2.8 - SIDE B SCALE: 1/2” = 1’-0”
NOTE: FS2.7 SIGN IS EXISTING SIGN. MESSAGING TO BE UPDATED TO REFLECT LAYOUT BELOW.
NOTE: FS2.8 SIGN IS EXISTING SIGN. MESSAGING TO BE UPDATED TO REFLECT LAYOUT BELOW.
NOTE: FABRICATOR TO COORDINATE FINAL MESSAGING WITH OWNER.
PROJECT NUMBER:
DATE:
REVISIONS:
1
2
3
4
5
DRAWN BY:
SCALE:
COMPONENT NAME:
SHEET:
300 Spruce ST. Suite 300
Columbus Ohio 614.461.4664
TRI-C WESTSHORE EXTERIOR SIGNAGE
DOCUMENTISSUE SET
TH
EX-24
05.20.2019
05.30.2019 -Addendum
16213
1
23
4
5
N.T.S. U.N.O.
11”x17” Page Size
FS3 - SINGLE POST SIGN
DARK GREY PMS 432CPAINTED BENJAMIN MOORE STONECUTTER 2135-20
TRI-C TURQUOISE PMS 321CPAINTED BENJAMIN MOORE ARUBA BLUE 2048-30
WHITE VINYLGERBER A6 OPAQUE MATTE WHITE A6002-O
1 FS3 - SINGLE POST SIGN - ELEVATIONSCALE: 3/4” = 1’-0” 2 FS3 - SINGLE POST SIGN - SIDE
SCALE: 3/4” = 1’-0”
NOTE TO FABRICATOR:FABRICATOR TO SURVEY EXISTING SITE SIGNAGE. THIS SIGN TO MATCH EXISTING FREESTANDING SIGN ON TRI-C WESTSHORE CAMPUS. SIGN RENDERINGS, PLAN, ELEVATIONS, SECTIONS DRAWN BY STUDIO GRAPHIQUE ARCHITECTS AND PROVIDED TO MOODY NOLAN.
EXISTING SIGNS
SECOND FLOOR
116'-0"
THIRD FLOOR
131'-4"
A-5202
Sim
2'-0
"2'
-0"
8 1/
8"29
'-3 7
/8"
8"1'
-10"
3'-6
"2'
-0"
2'-0
"2'
-0"
3'-5
1/4
"
DEAN OFFICE201D
07 21 00.CSPANDRAL GLASS INSULATION
08 81 00.CEXTERIOR INSULATEDSPANDREL
07 42 44METAL COMPOSITE MATERIALS
07 48 00RAINSCREEN ATTACHMENTSYSTEM
07 21 00.BRIGID INSULATION -POLYISOCYANURATE
09 21 16.M65/8" GYPSUM EXTERIORCEILING BOARD
07 21 00.ESOUND ATTENUATINGBLANKET INSULATION
09 21 16.M45/8" GYPSUM EXTERIORSHEATHING
07 27 26FLUID-APPLIED VAPORPERMEABLE AIR BARRIER
05 58 00.ACOLUMN COVERS
A-5218
Sim
WESTSHORE - PHASE IIEXTERIOR SIGNAGE SUPPLEMENTAL INFORMATION (REFERENCE ONLY)BUILDING SECTION AT SIGN "BN1"
EXTERIORSIGNAGE PERSIGNAGE BIDDOCUMENTS(NOT TO SCALE)
2'-6
"
INTERIOR METAL STUD KNEE WALLBEHIND SPANDRAL GLASS
RUNTAL (FINTUBE) HYDRONICHEATING ELEMENT (NOT TO SCALE)
POWER (2 locations behind BN1)LOCATED IN SPACE BELOW RUNTALHEATER
METAL PANELS, SUBFRAMING,AND INSULATION WILL BEREMOVED BY OTHERS TOFACILITATE SIGNAGE (ANDRELATED WIRING) INSTALL. FINAL COORDINATION TOOCCUR AFTER BID WITH CM ANDOTHER PRIME CONTRACTORS.SIGN INSTALLER TO SEAL ALLPENETRATIONS THROUGH AVB.SIGN INSTALLER TO CUT/PATCHDRYWALL AS REQUIRED.
WESTSHORE - PHASE IIEXTERIOR SIGNAGE SUPPLEMENTAL INFORMATION (REFERENCE ONLY)BUILDING SECTION AT SIGN "CS1"
PENTHOUSE FLOOR
146'-0"
PENTHOUSE ROOF T/STEEL
161'-4"
T/PARAPET
150'-8"
T/ROOF
163'-8"
07 42 17INSULATED COMPOSITEBACK-UP PANELS & LOUVERS
13'-4
"4'
-0"
3 5/
8"
2'-4
"2'
-4"
PENTHOUSE400
08 44 13.MGLAZED ALUMINUM CURTAINWALL FRAMING EXTENDEDFACE CAP
2'-0
"2'
-0"
07 42 44METAL COMPOSITE MATERIALS
07 62 00.HPREFINISHED ALUM COPING
A-5227
LOUVERS DONOT OCCURAT CS1 SIGN. SEEELEVATION
SCALE: 1/4” = 1’-0”
5'-0" AFF(PENTHOUSE)
POWER LOCATED INPENTHOUSE APPROX 5'AFF AS NOTED BELOW.
METAL PANELS, SUBFRAMING,AND INSULATION WILL BEREMOVED BY OTHERS TOFACILITATE SIGNAGE (ANDRELATED WIRING) INSTALL. FINAL COORDINATION TOOCCUR AFTER BID WITH CM ANDOTHER PRIME CONTRACTORS.SIGN INSTALLER TO SEAL ALLPENETRATIONS THROUGH AVB.SIGN INSTALLER TO CUT/PATCHDRYWALL AS REQUIRED.
WESTSHORE - PHASE IIEXTERIOR SIGNAGE SUPPLEMENTAL INFORMATION (REFERENCE ONLY)BUILDING SECTION AT SIGN "CN1"
THIRD FLOOR
131'-4"
PENTHOUSE FLOOR
146'-0"
T/PARAPET
150'-8"
1'-2 1/4" 1'-0"
09 21 16.M45/8" GYPSUM EXTERIORSHEATHING
05 40 00.A86" METAL STUD
2'-4
"2'
-0"
2'-0
"2'
-0"
2'-0
"2'
-0"
2'-0
"2'
-0"
2'-0
"2'
-0"
2'-0
"
07 48 00.A1-1/2" VERTICAL CI GIRT
07 48 00
A-52012
Sim
CLASSROOM - 24T307
CUYAHOGACOMMUNITY
COLLEGE
11'-0" AFF(LEVEL 3)
POWER LOCATED INCEILING AREA APPROX11' AFF AS NOTEDBELOW.
METAL PANELS, SUBFRAMING,AND INSULATION WILL BEREMOVED BY OTHERS TOFACILITATE SIGNAGE (ANDRELATED WIRING) INSTALL. FINAL COORDINATION TOOCCUR AFTER BID WITH CM ANDOTHER PRIME CONTRACTORS.SIGN INSTALLER TO SEAL ALLPENETRATIONS THROUGH AVB.SIGN INSTALLER TO CUT/PATCHDRYWALL AS REQUIRED.
Top Related