Accessories FOR HELIAX® PRODUCTS
PRODUCT SE L ECT ION GU IDE 2007
Table of Contents
�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
A
B
D
A
D
E
F
C
A CableHoistingandAttachment
B Weatherproofing
C CableEntry
D GroundingKits
E GroundingBars
F ArrestorPlus®SurgeArrestors
Introduction
Cable Installation Accessories
Cable Hoisting and Attachments ................................................. 8
Weatherproofing ....................................................................... 19
Cable Entry ............................................................................... 22
Installation Aids......................................................................... 24
Lightning Protection
Grounding Kits .......................................................................... 30
Grounding Bars ......................................................................... 34
Surge Arrestors ........................................................................ 37
Appendixes
Appendix 1: Quarterwave Stub Surge Arrestors ....................... 40
Appendix 2: Gas Tube Surge Arrestors .................................... 43
Appendix 3: dc Passing T-Series Surge Arrestors .................... 46
Appendix 4: Lightning Strike Probability .................................. 47
Appendix 5: Additional Documents .......................................... 48
Appendix 6: Hanger Spacing Guidelines .................................. 49
Index ............................................................................................... 58
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�
Andrew’s Clear Advantage
Around the globe, in a world being transformed by communications, people anticipate more than ever that wireless services will enhance their lives, workplaces, and communities.
Withtheconvergenceofvoice,data,andvideo,weexperiencethepromiseofmobility—andweexperienceAndrew.Andrewsupportstheemergingmobilesociety,andthecompaniesthatmakethistoday’sreality,withcompletewirelesssolutions.Ourcustomersrepresenttheleadingwireless,broadband,andsatellitecommunicationprovidersoftheworld.WesupportallmajoroperatorsandOEMsineveryregionandareextremelyproudoftheserelationships,manyofwhichwehaveservedfordecades.
Andrewsolutionsaretechnologyagnosticandunbiasedregardingplatform,frequencyandtechnologyevolution,evenwithinourownproductportfolio.
Withourbroadbaseofproducts,wesupportmoreglobalmarketsandoffermoreknowledgeandexperienceinlicensing,spectrumanalysisandutilization,assetoptimization,andcustomized,multi-prongproblem-solvingforbuilding,optimizing,andenhancingnetworksforgrowthandsuccess.
Simply,weunderstandyourchallengesandareuniquelypreparedtohelpasanunmatchedone-stopresourceformanagingtheentirelifecycleofwirelessnetworks.
AndrewprovidesproductsandsolutionsfortheentireRFfootprintwithourAntennaandCablepassiveproductsandourWirelessNetworkSolutionsactiveproducts.Oursubstantialinvestmentinglobalresearchanddevelopmentensuresapipelineofnewproductsandsolutionsthataddressourcustomers’evolvingnetworkrequirements.
TheAndrewflashrepresentsanenviable70-yearlegacyofcustomerservicethatbringsustotoday,withover11,000employeesin35countries,andanunmatchedglobaldistributionnetworkthatensuresthatourcustomersreceiveessentialsupportwhereverandwhenevertheyneedit.Ourtalents,expertise,andcommitmentarealwaysnearby,andourlocalpresenceineveryregionoftheworldensurescost-effectiveproductsandon-timedeliveryandservices.
Everywhereyoulook,thepromiseofmobilityishere—andweatAndrewpromisetolisten,anticipate,andinnovate,andtocontinuetoearnthetrustandrespectofourcustomers.
�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
n BaseStationAntennaandRemoteElectricalDowntiltSystems
n MicrowaveAntennas
n CoaxialFoam,Air,andSpecialtyCable
n Connectors,SurgeArrestors,andAssemblies
n BroadbandCables
n SiteInstallationProductsandServices
n BiasTees
ANTENNA AND CABLE PRODUCTS
n Single-CarrierPowerAmplifiers
n MulticarrierPowerAmplifiers
n CustomIn-CabinetAmplifiers
n CustomIn-CabinetFilters
n TowerMountedAmplifiers
n Filters/Combiners
n IntegratedProducts
n Micro/PicoCells
n RemoteRadioHeads
n AfterMarketServices
BASE STATION SUBSYSTEMS
n GeolocationandLocationBasedServices/GeolocationMobileLocationSolutions
n SpectrumManagement
n NetworkOptimization
n NetworkInfrastructureandProgramManagement
n AdvancedDataCollection
NETWORK SOLUTIONS
n RFRepeaters
n RFBoosters
n OpticalDistributionNetworks
n RadiatingCable
n PassiveSplitters,Combiners,Duplexers,Terminators,andIndoorAntennas
n OperationsandMaintenanceCenter
n TurnkeySystemDesignandProjectManagement
WIRELESS INNOVATIONS
n Direct-to-HomeOutdoorUnits
n VerySmallApertureTerminalOutdoorUnits
n EarthStationAntennas
n GatewaySystems
n MilSatComAntennaSystems
n Government/RadarAntennas
n RFElectronics
n SiteInstallationandServices
SATELLITE COMMUNICATIONS
Antenna and Cable Products Segment Wireless Network Solutions Segment
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�
Planning SoftwareAASP—the first and only PCS/Cellular Systems Design Software
DesignyourPCSorcellularsysteminlesstime,withgreateraccuracyand
lowercostswithadvancedAndrewAntennaSystemsPlannersoftware(AASP).PowerfulAASPsoftwaregraphicallyguidesyouthroughtheentiredesignprocess,fromthechoiceoffrequencytotheavail-
ableshippingoptions.Theprogram’sdynamic,rule-basedlogicgenerates
customsolutionsbyusingstandardAndrewproductswhileautomaticallycheckingcomponentcompatibility.Uponcompletion,AASPprovidesyouwithacustomizedbillofmaterialsoftheAndrewpartsnecessaryforthesystem.AASPisavailableontheAndrewPowertools™CDorasadownloadfromwww.andrew.com.
OnePackSM Site KitsThe Answer for More Efficient System Build-outs
Today’sglobalbuild-outdemandsnewsolutionsthatspeedsystemdeploymentandsimplifysupplychainmanagement.Tohelpsystemmanagersbetterachievethesegoals,Andrewofferskitsforwire-lessRFcommunicationssystemssites.OnePackSiteKitsprovidethecriticalcomponentsineasytoorder,easytomanagepackages.Systemdesignersandmanagerscanbeconfidentofshortenedprojectplanningandexecutioncycles,improvedefficiency,anddependablesystemperformance.
Customer Support Center (CSC)Service Around the Clock, Around the World
Contact the Andrew Customer Support Center for:
dTechnicalsupport
dOrderstatus
dCoordinatingproductservice,repairs,orreplacement
dProductinformation
dReplacementmaterials
Call toll free from:
NorthAmerica 1-800-255-1479Fax 1-800-349-5444
International:UnitedKingdom 0800-250055Australia 1800-803219NewZealand 0800-441-747Callfromotherareas: +1708-873-2307
Services
Installation Techniques to Ensure Quality!Andrewproductsandpeopleareattheforefrontofconnectingthewirelessworld.Astheindustryevolves,theAndrewInstitute®iscommittedtoprovidingyouwithquality,effectivetraining.Ourtrainersdeliverknowledgethatcandevelopyourskillsandself-assurance,aswellasbenefityoursystemperformanceandreliability.DedicatedAndrewInstitutetrainerswillsharetheirproveninstallationtechniquesandexpertisewithyouinone-ortwo-daysessions.
“Build an Agenda” Customize Your Training:
Connector Attachment
(1hourperconnector)
dCableconcepts
dConnectorattachment
dAccessories
RET Antenna
(2hours)
dAntennaconcepts
dMountingtechniques
dWeatherproofing
dInspectionandmaintenance
�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.comAndrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com �
MorecustomersaremandatingthattechniciansinstallingtheirsystemsareregisteredashavingcompletedAndrewInstitutetraining.
OrlandPark,IllinoisUSA
Lochgelly,Scotland
Sorocaba,Brazil
Suzhou,China
Andrew Institute Technical TrainingYou will learn:
dHowtoobtainthehighestpossibleperformancewitheveryAndrewproductinstalled
dSystemfundamentalsandhowcomponentsworktogether
dProperinstallationofcable,connectors,andaccessoriesthroughhands-onpractice
dTMWsystemsfundamentalsandessentialelementsofpathalignment
dPressurizationsystemstheoryofoperationandinstallationtechniques
dProperpathalignment
dFundamentalsofVSWRsweeptesting,insertionloss,andTDR/FDRplots
TheAndrewInstitutewelcomestheopportunitytoservetheindustry.Wecanbringselectcoursestoyourfacility,oryoucancometoanyoneofourconvenienttraininglocations.
Terrestrial Microwave Systems
(2days)
dRFtheory/TMWfundamentals
dAntennainstallation
dPathalignment
dPressurizationfundamentals
For more information visit our Web site at: www.andrew.com
Registration is available online or call: +1-779-435-6231
Fundamentals of VSWR
(4hours)
dTypicalsiteconfiguration
dPlot/sweepinterpretation
dTroubleshooting
Selection Guide
Elements of a Cable Mounting and Protection System
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�
Once you’ve selected the cable and connectors for your system, the cable mounting and protection system must be planned. Andrew offers a comprehensive line of installation accessories and lightning protection systems to help you realize your communications system’s full potential.
Hoisting Grips
Selectahoistinggriptosafelyraisethecableandholditduringhangerattachment.Insomecases,ahoistinggripmustalsobeusedwithacalibratedclamp,availablefromAndrew,toprovidepermanentsupportforthecable.
Hangers
Thetypeorshapeofthestructure,thespaceavailableforcableattachment,thetypeofenvironmentthesystemwillbeexposedto,andtheeaseofinstallationormaintenancearekeyconsiderations.Manyhangeroptionsareavailable,andmanyvariableshavetradeoffsthataffecttotalhangersystemcost.Thetableonpage18willhelpyouselectthebesthangersforyoursystemandbudget.
Weatherproofing
Weatherproofingkeepsconnectorinterfacestightandaddsanadditionallayerofprotectionagainsttheenvironment.Andrewoffersthreetypesofweatherproofing.Astandardweather-proofingkitprovidesuniversalcoverageandusesbutylandvinyltapestowrapconnectorsurfaces.Our3M™ColdShrink™weatherproofingkitusesaself-shrinkingtechnologytoreduceinstallationtime.NewWeatherShield™enclosuressealandprotectconnectorsfortheenvironmentinseconds.
Cable Entry
Thefinalstepinabasestationinstallationistobringthecableintothebuildingorradiocabinet.Twobasictypesofcableentrysystemsareavailable:astandardbuildingentry,andanintegratedsystemthatcombinescableentryandlightningsurgesuppressionintooneefficientsystem.
Grounding Kits
Agroundingkitdivertstransientcurrentsfromlightningoffthetransmissionlinetoanearthgroundingsystemtopreventdamagetocableandradioequipment.Atypicalinstallationusesthreegroundingkits:nearthetopofthemainfeedercable,atthebottomofthemainfeederpriortothehorizontalrun,andjustpriortothecableenteringthebuilding.Andrewoffersthreekittypestomeettherequirementsofyoursystemandbudget.
Surge Arrestors
AndrewArrestorPlus®surgearrestorsprovidethelaststageofaneffectivelightningprotectionsystem.Installthemtodivertlightningtransientsofftheinnerconductorofyourcoaxialcablebeforetheyreachyourradioequipment.Selectfromavarietyofsurgearrestorstomeetyourexactrequirements.
( Cable Hoisting and Attachment
( Weatherproofing
( Cable Entry
( Installation Aids
CA
BLE INSTA
LLATION
AC
CESSO
RIES
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�
Support/Hoisting GripSafer, Faster Cable Hoisting
Liftandsupportcableinyourmonopoleoronyourtowerfasterandmoresafelyandwithoutthethreatofslippage.Ourone-piecegripandlockingclampspeedandsimplifyinstallationbyeliminatingtimeconsuminglacing.
Useat200ft(60m)intervalstoraisecableandprovidepermanentcablesupport.Basickitincludesonegripandonesupportclamp.Supportclampsarealsoavailableinkitsof10.Installationtoolisrequired.
Part Number Part Number
Support Grip Support Clamp Cable Size Cable Type
F1SGRIP F1SGRIP-1IK 1/4" FSJ1L1SGRIP L1SGRIP-1IK 1/4" LDF1E2SGRIP E2SGRIP-2IK 3/8" EFX2L2SGRIP L2SGRIP-2IK 3/8" LDF2F2SGRIP F2SGRIP-2IK 3/8" FSJ2C2SGRIP C2SGRIP-2IK 3/8" CNT-400L4SGRIP L4SGRIP-4IK 1/2" LDF4F4SGRIP F4SGRIP-4IK 1/2" FSJ4L45SGRIP L45SGRIP-45IK 5/8" LDF4.5L5SGRIP L5SGRIP-5IK 7/8" LDF5, VXL5L6SGRIP L6SGRIP-6IK 1-1/4" LDF6, VXL6L7SGRIP L7SGRIP-7IK 1-5/8" LDF7, VXL7L12SGRIP L12SGRIP-12IK 2-1/4" LDF123CCGRIP — — RET cablePart Number DescriptionSG-IT Support Clamp Installation Tool
Standard Hoisting Grip For Transmission Line Installation
Useat200ft(60m)intervalstoraisecableontower.Usewithaddi-tionalsupportclamptoachieveoptimumcablegrip.
Part Number Part Number
Hoisting Grip Support Clamp Cable Size
43094 L4SGRIP-4IK 1/2"29958 L45SGRIP-45IK 5/8"19256B L5SGRIP-5IK 7/8"29961 L6SGRIP-6IK 1-1/4"24312A L7SGRIP-7IK 1-5/8"31535 L12SGRIP-12IK 2-1/4"26985A — 3"34759 — 4"31031-1 — 5"
Use the support/hoisting grip whenever possible. Rely on the standard, lace up hoisting grip only when connectors are pre-attached or you have to place a grip in the middle of a cable run over 200 ft.
TIP!
TIP!
Cable Installation Accessories
Cable Hoisting and Attachment
�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Snap-In Hangers Attachment with No Hardware!
AndrewSnap-Inhangersprovidequickandeasyattachmentinalltypesofweather.Thehangerssnapdirectlyintoholesinthetowersupportmembers.Installationtimeandcostsaresubstantiallyreduced.Thesehangersfeaturecablegrippingtabstopreventcableslippage,andareconstructedofheavygaugestainlesssteelforhighstrengthandexcel-lentcorrosionresistance.WaveguideversionsincludeaheavyUVresis-tantrubberinserttosecuretheellipticalwaveguide.
Part Number Description206706A-6 For 5/8" cable206706A-5 For 2-1/4" cableEWSH-52 For EW52 waveguideEWSH-63 For EW63 waveguideEWSH-64 For EW64 waveguideEWSH-77 For EW77 waveguideEWSH-90 For EW90 waveguideEWSH-127A For EW127A waveguideEWSH-132 For EW132 waveguideEWSH-180 For EW180 waveguideEWSH-220 For EW220 waveguideEWSH-240 For EW249 waveguide
SnapStak™ HangersNo more worries about fumbling with hardware or losing small parts—because there aren’t any!
Newantennasystemscannowbeaddedtocrowdedmultiple-tenanttowers—withminimalspace!SnapStaksnap-inhangerscanbestackeduptothreedeepwhenusing1/2inand7/8incoaxialcable,ortwodeepwhenusing1-1/4inand1-5/8incoaxialcable.EachhangeraccommodatesonerunofHELIAX®cable.
Thedistinctive,self-containeddesignoftheSnapStakstackablesnap-inhangereliminatestheneedformountinghardwareandinstallationtools.Thissimplifiescoaxialcableinstallations,loweringbothtimeandcost.
RetentiontabsonthespringforkmakeSnapStakhangershighlyresis-tanttopop-out,soinstallationsarerobustandsecure.Yet,speciallydesignedtodampenvibrations,SnapStakhangersdonothavearigidholdonthetower,somotioncausedbywindissimplyabsorbed.Thisreducesmovementdownthecoaxialcable,greatlyreducingstressontheconnectionsatthejumpercable,antenna,ordevice.
SnapStakhangerscanbemounteddirectlytothetowersupportsystem,orusedinconjunctionwithavarietyofmountingaccessoriesforrooftops,buildings,andwatertowers.TheSnapStakhangerinstallsin3/4inholesinsupportstructures1/8in(0.120into0.150in)thick.ThestainlesssteelconstructionoftheSnapStaksnap-inhangerprovidesexceptionalintegrity,eveninhighlycorrosiveenvironmentsandextremeweatherconditions.Compactinstallationssavetowerspace.Andmaintenanceiseasy,sinceSnapStakstackablesnap-inhangersareselfsufficient—nohardwarerequiredforinstallation!Mountstopre-punched3/4in(19mm)holes,kitof10.
Part Number DescriptionSSH-12 SnapStak hanger kit for 1/2" corrugated cableSSH-78 SnapStak hanger kit for 7/8" corrugated cableSSH-114 SnapStak hanger kit for 1-1/4" corrugated cableSSH-158 SnapStak hanger kit for 1-5/8" corrugated cableSSHAK-3812 SnapStak hanger kit for RET cableSSHA-38 Insert, adapts 1/2" snap in hanger to RET cableUnitedStatesPatents:6,345,543,6,899,305,and6,161,804.Otherpatentspending.
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0
Snap-In Tower StandoffsFormountingsnap-inhangerstoroundsupportmembers.Adapterisdesignedwith3/4inpre-punchedhole.Adapterprovides2-1/2in(60mm)standoff.Allpartsarestainlesssteelorgalvanized,kitof10.
Part Number Member Diameter, in (mm)STS3-12 1–2 (25–50)STS3-23 2–3 (50–75)STS3-34 3–4 (75–100)STS3-45 4–5 (100–125)
SnapStak™ Hanger ToolSpeciallydesignedpliersmakeinstallationandremovalofSnapStaksnap-inhangersextremelyeasy.Thespringloadedpliersaredesignedwithahookthatholdsandspreadsthehangeropentoslipeasilyoverthecable.Serratedpadsthensqueezethehangertogetherforeffortlessinsertionintothemountingstructure.Insulatedhandleandalanyardholemakeiteasytohangonto.
Part Number Description SHT-4 SnapStak hanger tool, quantity 1
Part Number DescriptionUA-3 Universal snap-in adapter, kit of 10
Universal Angle Adapter InsertInserttransitionstheuniversaladapter’s3/4intoa3/8inholediameter,whichallowstheuseofstandardhangers.
Part Number DescriptionUAAI Universal angle adapter Insert, kit of 10
Eachpartsoldseparately
(UA-3
(UAAI
Universal Snap-In AdapterTheuniversalsnap-inadapterisaversatiledeviceforsecuringcoaxialcablehangerstostructuressuchascommunicationstowers,rooftops,buildingsandwatertowers.
Theuniversalsnap-inadaptersecurescoaxialcabletoanyroundorangletowermemberswherepre-punchedholesarenoteasilyacces-sible.Theadapterhasapre-punched3/4inholethatallowstheinstallertomountcablehangerssuchasAndrewSnapStak™snap-inhangerstowirelesscommunicationstowersorotherstructures.Stainlesssteelconstructionforlonglife.
Universal Adapter Applications
Cable Installation Accessories
Cable Hoisting and Attachment
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Cluster Support BracketTheclustersupportbracketisaversatilemeanstosupportmultiplerunsofcoaxialcableinvirtuallyanyapplication.Theovaldesignallowscoaxialcabletoberuninsideandoutsideofthebracket,whichmaxi-mizesitscapacity.Eachbracketfeatures3/4inholestoaccommodatesnap-inhangersand3/8inholesforbutterflyhangersusingstandard3/8inhardware.Theclustersupportbracketsupportssevenrunsofcoaxialcable.Soldinunitsofone,U-bolthardwaresoldseparately.
Part Number Description CS-B Cluster support bracket with U-bolt for 2-3/8" round member attachment
PVC Roof SleeperSupportrooftopcoaxialcablerunsusingthesnap-inPVCroofsleepers.PVCroofsleepersarepre-punchedwith3/4inholestoaccommodatesnap-inhangers.Sleepersaremadeofagray4in(102mm)x4in(102mm),UV-resistantPVCmaterial.
Part Number DescriptionMT-F1598 4 run, 22" (559 mm) lengthMT-F1599 8 run, 32" (810 mm) lengthMT-F1600 12 run, 43" (1102 mm) length
Snap-In Adapter BracketThisbracketisusedinconjunctionwithWRAPLOCK®andisusedonlarge,roundmembers,watertowers,oroutsideofamonopole.ThebracketsslideontheWRAPLOCKandholduptosixrunsofcoaxialcable.Youcanusemultiplebracketsforthenumberofrunsrequiredforyoursystem.Thegalvanizedsteelbracketsupportsbothstandardhangersandsnap-inhangers.Accommodatessixrunsofsnap-inhangersandfourrunsofclick-onhangers.
Part Number DescriptionRM-USBG Snap-in adapter bracket, kit of 1012395-1 Stainless steel WRAPLOCK
Universal Snap-In BracketThesegalvanizedsteelbracketsaredesignedtoworkonbothangleandroundmembers.Theyarepre-punchedwith3/4inholestoholdsnap-inhangersorstandardhangers.
Part Number DescriptionSS-TB2550 Universal snap-in bracket, for 1-1/2" to 5-9/16" round member 2-1/2" to 5" angle member. Accommodates six snap-in or standard hangers.SS-TB6080 Universal snap-in bracket, for 6" to 10-3/4" round member 6" to 8" angle member accommodates six snap-in or standard hangers.
Anchor Rail AdapterAnchor rail adapters make cable installation fast, secure, and neat.
Theseone-piece,one-size,self-containedanchorrailadaptersrequirenotoolsandsnapintocommonstrutoranchorrailsystems,suchasUniStrut®MetalFraming.The3/4inholeacceptscommonsnap-inhangers.Adapterscanbeusedforhorizontalorverticalcabletoproduceneatlyalignedinstallationsonlargepoles,smokestacks,rooftops,walls,oranysupportstructure.UnitedStatesPatent:7,090,174.UniStrutisaregisteredtrademarkoftheUniStrutCorporation
Part Number DescriptionARA-22 Anchor rail adapter for 0.86" (22 mm) rails (North American standard), kit of 10
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
AngleAdapterAttachment
CeilingAdapterAttachment
Part Number Attachment Hardware243684 Compact angle adapter, see page 16 for details244350 Ceiling adapter, kit of 10Roundmemberadapter(varioussizes)seepage16
RoundMemberAttachment
FlatMemberAttachment
Click-On HangersClick-On Hangers—Install Cable with One Easy “Click”
SpecificallydesignedtosupportHELIAX®coaxialcable,stackableclick-onhangersinstallinjustminutesandprovideaperfectfitthatgivesyourPCS/PCN,cellular,microwave,ruraltelephony,GSM,orothertelecommunicationssystemaprofessionalappearance,especiallyinconfinedspaces.
Availableineithersingleordoubleversions,click-onhangersaremanufacturedoftoughUV-resistantmaterialandsetthestandardfordurability,simplicityofinstallation,andcosteffectiveness.UnitedStatesPatent:5794897.
Double Single*
Part Number Part Number DescriptionL4CLICK L4SCLICK 1/2" hanger, kit of 10L45CLICK — 5/8" hanger, kit of 10L5CLICKB L5SCLICKB 7/8" hanger, kit of 10L6CLICK L6SCLICK 1-1/4" hanger, kit of 10L7CLICK L7SCLICK 1-5/8" hanger, kit of 10
Snap-In Adapter BlockThissnap-inadapterblockisdesignedtoaccommodateasnap-inhangeroneachsideoftheblock.Youcanattachthistothetowerwithourstandardangleadaptersortowerstandoffs.Stainlesssteelconstruction.
Part Number DescriptionSA-38 Snap-in adapter block, kit of 10
Cable Installation Accessories
Cable Hoisting and Attachment
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Click-On Hanger Hardware KitsClick-onhangerattachmenthardwareisavailablein3/8inorM10sizes.Constructedofstainlesssteelfordurability.Selecthardwarelengthaccordingtoplannedhangerstackheight.Eachkitcontains10threadedrods,30nuts,40flatwashersand20lockwashers.Note:Click-onhangersaccommodatetworunsofcableandcanbestackeduptothreedeeptohandleuptosixruns.
Part Number Stack Height Cable Size Rod Length (# of hangers) in (mm)
Imperial
243095-9 1 1/2" or 7/8" 3.75 (95)243095-5 2 1/2" or 7/8" 5.40 (137)243095-1 3 1/2" or 7/8" 7.00 (177)243095-10 1 1-1/4" or 1-5/8" 4.75 (121)243095-6 2 1-1/4" or 1-5/8" 7.25 (184)243095-2 3 1-1/4" or 1-5/8" 9.75 (248)
Metric
243095-11 1 1/2" or 7/8" 3.97 (101)243095-7 2 1/2" or 7/8" 5.50 (141)243095-3 3 1/2" or 7/8" 7.10 (181)243095-12 1 1-1/4" or 1-5/8" 5.00 (126)243095-8 2 1-1/4" or 1-5/8" 7.30 (186)243095-4 3 1-1/4" or 1-5/8" 9.90 (251)
Miniature Click-On HangersFast, easy installation for small cables
Nowinstallingsmallcablesintohangersisaccomplishedinoneeasyclickwithminiatureclick-onhangers.
Eachcompact,miniatureclick-onhangersaccommodatestworunsofcable.Miniatureclick-onhangersarecompactandstackable,makingiteasytoinstallseveralrunsofcableinconfinedspaces.
Miniatureclick-onhangersarecosteffectiveanddurable.Withflexiblegrippingribs,thehangerprovidessecuresupportonarangeofcablesizes,andindexingonthehangerbodyhelpsaligncablesduringinstallation.
Specificallydesignedtoaccommodatesmallcorrugatedcoaxialcables,ellipticalwaveguide,andbraidedcableruns,miniatureclick-onhangersprovideaperfectfitforyourinstallation.Hangersarepackedinkitsof10.Attachmenthardwaremadeofanti-corrosioncoatedmetalforlongservicelifeissoldseparatelyinkitsof10.
UnitedStatesPatent:7,007,900.
Select hardware by intended hanger stack height.
Part Number Description68MCLICK Click-on hangers for 6-8 mm cable; FSJ1A, CNT-240, CNT-300912MCLICK Click-on hangers for 9-12 mm cable; LDF1, EFX2, FSJ2, LDF2, CNT-400, EW3801316MCLICK Click-on hangers for 13-16 mm cable; FSJ4, LDF4-50A, CNT-500, CNT-600
Part Number Description252026-10KT Mini angle adapters, M8 tap252027-10KT Single stack hardware for mini click-on hangers, M8 thread252028-10KT Double stack hardware for mini click-on hangers, M8 thread 252029-10KT Triple stack hardware for mini click-on hangers, M8 thread
Multi-run hangers are the best choice for installing cables where space is very limited on crowded towers.
TIP!
TIP!
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
KwikClamp™ HangersMultiple Run Cable Hangers for European Norms
IdealformultipleruncablehangersdesignedexclusivelyforEuropean-styletowers,costeffectiveKwikClampcablehangerseliminatetheneedfordrillingandadapters.Theseself-clampingcablehangersattachdirectlytoroundorflattowermembers,providingsturdy,reliable,long-termsupporttosystems.Hangersaresoldinkitsof10.
KwikClamp Ordering Information
SeethetablebelowtobuildaKwikClamppartnumberforyourapplication.
1 Select your cable size and note the base part number shown below that cable size.
2 Select the tower member type and the number of cable runs for your application.
3 Locate the part number detail at the junction of the cable size column and the tower member type row. The base part number plus the part number detail indicates the full part number.
Forexample,theKwikClamphangerpartnumberforthreerunsof7/8inchcableonan8–25mmroundtowermemberisL5CLAMP-RDN-3.
Cable and Hanger Type
Cable Size RG8 1/2" 5/8" 7/8" 1-1/4" 1-5/8"
Base Part Number R8CLAMP-( ) L4CLAMP-( ) L45CLAMP-( ) L5CLAMP-( ) L6CLAMP-( ) L7CLAMP-(
Tower Member Type # of Runs Part Number Detail
3-11 mm 2 UNV-2 — — — — —
8-25 mm round or3-25 mm flat plate 1 — RDN-1 RDN-1 RDN-1 RDN-1 RDN-1 2 — RDN-2 RDN-2 RDN-2 RDN-2 RDN-2 3 — RDN-3 RDN-3 RDN-3 RDN-3 RDN-3
Cable Installation Accessories
Cable Hoisting and Attachment
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Standard HangersStandard Hangers and Hardware—For Security and Flexibility
Standardhangersaredesignedforeasyinstallation.Theclamplockingboltandnutarepre-assembledandcaptivatedtominimizeinstalla-tionlabor.Propertensioniseasytodetermine.Thehangerissimplytighteneduntilthereisa5/16ingapbetweentheclamplegs.Thepre-drilledholefor3/8inor1/2inmountinghardwareandslotsforroundmemberadapterclampsfurthersimplifyinstallation.Seepages16–18foraccessoriestoadaptthesehangerstomosttowerconfigurations.
PleaserefertoAppendix6forspecificrecommendations.
Hanger Part Number Cable Size Photo Reference43211A 3/8" A43211A 1/2" A42396A-9 5/8" B42396A-5 7/8" B42396A-1 1-1/4" B42396A-2 1-5/8" B42396A-4 2-1/4" B31766A-11 3" C31766A-10 4" C
Hanger Waveguide Part Number Size Photo Reference31766A-9 EW17 C31766A-10 EW20 C31766A-11 EW28 C42396A-4 EW37 B42396A-16 EW43 B42396A-8 EW52 B42396A-7 EW63 B42396A-1 EW64 B42396A-11 EW77 B42396A-5 EW85 B42396A-5 EW90 B42396A-9 EW127A B42396A-9 EW132 B43211A EW180 B43211A EW220 B43211A EW240 B
Hardware Sets, Kit of 10Imperialkitsinclude3/8infillister-headbolts,lockwashers,andnutsforattachmentofstandardhangerstodrilledtowermembers.ThemetrickitincludesM10boltsandlockwashersforusewithmetricangleadapters.
Part Number Length31769-5 3/4" (19 mm) 31769-1 1" (25 mm) 243684-MH Metric M10 19 mm
Additional Mounting HardwareThreaded Rod Support Kit for Standard Hangers.
Usetomounthangersawayfromsupportingstructure,undercablebridge,andinsideequipmentroom.Includes3/8indiameterthreadedrod,galvanizedceilingmountingplate,nuts,andwashers.Attachtoangletowermemberswith31768Aangleadapters.Attachtoroundtowermemberswith30848seriestowerstandoffs.Allcomponentsarestainlesssteel,exceptceilingmountingplate.
Part Number Part Number Rod Length, in (mm)
Kit of 1 Kit of 5
31771 31771-4 12 (305) 31771-9 31771-6 24 (610) — 31771-10 36 (915)
A B C
Cable Installation Accessories
Cable Hoisting and Attachment
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Angle AdapterStainlesssteel,kitof10.Formounting1/2into4incablehangerstoangletowermembersupto7/8in(22mm)thick.Includeshangerattachmenthardware.
Part Number Description31768A 3/8" hardware31768A-M Metric hardware
Round Member AdapterStainlesssteelclampstomount1/2into4incablehangerstoroundsupportmembers.Twoeachareneededfor3inand4incablehangers,kitof10.
Part Number Member Diameter, in (mm)31670-1 1–2 (25–50)31670-2 2–3 (50–75)31670-3 3–4 (75–100)31670-4 4–5 (100–125)31670-5 5–6 (125–150)31670-6 6–8 (150–200)
Angle Adapter Galvanized and Non-marring
Formounting1/2into2-1/4incablehangerstoangletowermembersupto3/4in(19mm)thick.Hangerattachmenthardwaresoldsepa-rately,kitof10.
Part Number Description247763-I Tapped for 3/8" hardware247763 Tapped for metric hardware
Compact Stainless Steel Angle AdaptersThesecompact,lightweight,highqualitystainlesssteelangleadaptersprovideacostsavingoptiontostandardadaptersformanywirelesssystemsthatuseHELIAX®coaxialcable.ThesecompactangleadaptersaresuitableforusewithsinglerunsofHELIAXcableupto2-1/4inindiameter.Whenusedwithourstackableclick-onhangers,theycanaccommodateuptosixrunsof1-1/4incableorsmallercableanduptofourrunsof1-5/8incable.Includes3/8inormid-hangerattach-menthardware,kitof10.
Part Number Description
243684 Imperialangleadapter,kitof10
243684-M Metricangleadapter,kitof10
Cable Installation Accessories
Cable Hoisting and Attachment
�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
45° AdapterUsewithangleadapterandthreadedrodsupportkittoplaceahangeratawaveguidebend,kitof10.
Part Number Description
42334 45 degree adapter, kit of 10
Clamp Head
Part Number DescriptionMF39901-10 Clamp head, kit of 10
Nylon Cable Ties For Jumper Cable AttachmentCabletiessecurecablebundleswherespaceislimited.Theyareanexcellentchoicefororganizingjumpercableswithinandbetweenradiocabinetsandforbundlingjumpercables.Nyloncabletiesprovidesupportforsmalldiametercable1/4into1/2in.Typicalapplica-tionsincludesecuringjumpercablesinbuildingsandalonghorizontalantennamountingarms.
Part Number Description40417 Nylon cable ties, 5/16" wide
14.5" long, kit of 50
Tower Standoff Adapterswithroundmemberclampsandhardwarefor1/2into4inhangers.Allpartsarestainlesssteelorgalvanized,kitof10.
Part Number Member Diameter, in (mm)30848-5 0.75–1.5 (20–40)30848-4 1.5–3.0 (40–75)30848-1 3–4 (75–100)30848-2 4–5 (100–125)30848-3 5–6 (125–150)
Hanger TypeConstruction
Cable runs supported
Primary applications
Typical installation time (minutes)***
Key feature
Benefits
Attachment capability (Tower member type)
Additional parts needed
Tower adapters (allows hanger attachment to various tower types)
SnapStak™ HangersStainless steel
1 to 3
Towers with pre-punched cable ladders, snap-in accessories
7
Attaches cables in compact bundles, saving tower space
•Fastest hanger installation; No additional hardware needed
•Attaches cables in compact three run bundles
•Impervious to environmental extremes
•Universal hanger accommodates all corrugated cables
•3/4" drilled cable ladder
•Various adapters (see pages 10–11)
None
•Cluster mount•Universal tower
adapter•Anchor rail adapter
Standard HangersStainless steel
1
Tower installations subject to high wind, high corrosion, and high ice
20
Stainless steel tensioning hardware
•Impervious to environmental extremes
•Adaptable to various tower configurations
•3/8" (M10) drilled cable ladder
•Various adapters (see pages 16-17)
Tower attachment hardware kit
•Round member adapter
•Angle adapter
Support/ Hoisting Grips*Tin coated bronze
1
Monopole towers
2
Calibrated clamp provides permanent cable support
•Quick installation•Monopole
application•Accommodates
single run of cable
• All towers and monopoles
None
• None required
Cable Ties**Nylon
1
Jumper cables and inter-rack cabling
—
Universal fastening
•Fits most cable sizes and tower members
•Quick installation•Inexpensive•Accommodates
single run of light-weight cable
• Round member, angle member, cable ladders
None
• None required
Conditions * Supportgriporhoisting/supportgriprequiredwithallcableinstallations ** Shouldonlybeusedwith1/2incableandsmaller *** Installationtimebasedona100ft(30m)runof7/8incablewith3ft(1m)hangerspacing.Monopoleapplicationapplied200ftintervals,2minutes.
Click-On Single, Double, or Miniature HangersEngineered plastic single or double
2 to 6
Rooftops, water towers, and towers with limited space
20
Stackable up tothree high
•Attaches cables in compact six run bundles
•Versatile and adaptable to almost any application
•Easy to install click-on design
•UV stable
•3/8" (M10) drilled hardware ladder
•Various adapters (see pages 12–13)
Threaded rod and hardware
•Round member adapter
•Angle adapter
KwikClamp™ HangersStainless steeland plastic
1 to 3
New or existingtowers
15
Built in toweradapter
•Requires no additional hardware for tower attachments
•Fits round, flat angle, and C-channel tower members
•Quick installation•UV stable
•Round member Angle member channel section
•Cable ladders
None
None required
Cable Installation Accessories
Hanger Selection Guide
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
NEW! WeatherShield™ Reusable Connection Protection Enclosures For In-Line Connectors, Antennas, and Tower Top Devices
CompleteyourtransmissionlineinstallationwithWeatherShieldconnec-tionprotectionenclosureswhichsealandprotectconnectorsfromtheenvironment.
Thisrobust,one-pieceweatherproofingenclosureoffersanadditionalmeasureofsystemprotectionbyprovidingahightemperatureresistant,watertightsealaroundtheconnectorswhilealsohelpingtodampenvibrationthatcanloosenconnectorinterfacesovertime.
Thereusableenclosurecontainsaninnovativetrifoldsealthatprovidescompletemoistureblockforinstalledconnectors.Theeaseofinstal-lationonhard-to-reachconnectionsandthelong-termprotectionprovidedbythisenclosuremakesitthemostcost-effectivesolutionavailabletoday.TheWeatherShieldconnectionprotectionenclosuretakesjustsecondstoinstall.Simplyplacethehousingaroundtheconnectorandsnapthetabstogether.
Notapes,tools,orshrinktubesarerequired.TheAndrewWeatherShieldconnectionprotectionenclosureswillaccommodateTypeNand7-16DINconnectionsandarecompatiblewithAndrewHELIAX®cable,SureFlex™cableassemblies,andmostbrandsofstandardjumpers.
Part Number DescriptionAWE-A12 Enclosure for 1/2" antenna connection/deviceAWE-7812 Enclosure for 7/8" to 1/2" connectionsAWE-11412 Enclosure for 1-1/4" to 1/2" connectionsAWE-15812 Enclosure for 1-5/8" to 1/2" connections
Cable Installation Accessories
Weatherproofing
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
More Information: See the installation video at www.andrew.com/ products/trans_line/heliax/weathershield.aspx
Cable Installation Accessories
Weatherproofing
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0
Part Number Minimum Application Diameter, in (mm)* Kit Coverage, Cable Size to Cable Size
Connectors, 7-16 DIN or Type N
245173 0.63–0.41 (16–10.0) 3/8" through 1/2" to 3/8" through 1/2"241475-13 0.80–0.29 (20–7.4) 1/4" through 5/8" to 1/4" through 1/2"245171 0.84–0.29 (2–7.4) 7/8" to 1/4" through 1/2"245172 1.20–0.29 (30–7.4) 1-5/8" or 1 1/4" to 1/4" through 1/2"245175 1.40–0.41 (36–10.0) 2-1/4" to 1/4" through 1/2"
Antennas, filters, amplifiers, 7-16 DIN or Type N**
245174 0.84–0.29 –(21–7.4) 1/2"–7/8" jumpers to antenna
*Minimumapplicationdiameteristhefullycompresseddiameterofeachtubeinthekit.**Andrew3M™ColdShrink™WeatherproofingiscompletelycompatiblewithAndrewbasestationantennas.SeespecialpublicationSP50030forspecificapplicationinformationontheuseofColdShrink™forantennainterfaces.
Weathertight Seal Quickly Installs in Three Minutes
Completeyourtransmissionlineinstallationwiththepremierweatherproofingproducttosealandprotectconnectors,splices,surgeprotectors,andjumper-to-antennainterfacesfromtheenvironment.Andrew3M™ColdShrink™weatherproofingprotectsyourinvestmentandyoursystem’sperformance.
No Tools Required
ColdShrinkweatherproofingsimplyslipsovertheconnectionandcompressesaroundtheinterface.Notapesorheatgunsarerequiredforsealingorshrinking.SimplyplacetheColdShrinkkitoverthecableandconnector,maketheconnection,andunwindthepull-tabapplicator.Onceitiscollapsed,itscontinuouscompressiondesignformsawatertightsealaroundthecable.DevelopedjointlybyAndrewand3M™Corporation,ColdShrinkweatherproofinghasprovenitselfinthousandsofhighpowercableinstallationsformorethan15years.
Fits up to 2-1/4 in HELIAX® Cable
Kitsareavailablefortransitionsfromlargertosmallerdiametercable,suchas1-5/8into1/2in,orforsamediametercable,suchas1/2into1/2in.Seethetableforpartnumbers.
3MandColdShrinkaretrademarksofMinnesotaMiningandManufacturingCompany
Self-fusing TapeSelf-fusingandmarkingtapeisatimesavingalternativetotraditionalbutylrubbersealanttapes.ThesiliconetapesareproducedfromspeciallyformulatedUV-resistantsiliconerubber.WhenappliedtoRFconnectors,thetapewrapsbondtogethergivingtheconnectionanadditionallayerofprotectionagainstwater,dirt,andvibration.Comparedtoconventionaltapes,self-fusingtapeisbotheasytoapplyandremovefromconnections.
Availableinthreecolorsoptions,self-fusingtapecanalsobeusedtocolorcodetowertopcableinstallations,makingiteasytolocatecablesformonitoringpurposes.
Part Number Description QuantityFT-TB Self-fusing tape, black .030" x 1.5" x 15' 2 rollsFT-TR Self-fusing tape, red .030" x 1.5" x 15' 2 rolls FT-TW Self-fusing tape, white .030" x 1.5" x 15' 2 rolls
Cable Installation Accessories
Weatherproofing
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Standard Weatherproofing Kit for Connectors and AntennasTheapplicationofsealingmaterialstoantennacableconnectionsprotectsthemfromweatherconditions.Theseincludemoisturepenetra-tionandlooseningofconnectionsfromvibrationscausedbystrongwinds.AndrewCorporationrecommendsweatherproofingtheseconnec-tionswithstandardweatherproofingtapessuchasbutylandplasticelectricaltapes.
dMainfeedercable-to-jumpercableconnectiondJumpercable-to-antennaconnection
Thiskitprovidesanadditionalmoisturesealforcableconnections.Italsopreventslooseningofconnectionsfromvibrationorotherexternalstresses,whichwouldeventuallyallowmoisturepenetration.Thesealedconnectionissuitablefortypicalexposedandburiedcableapplications.
Weatherproofing Connections Per Kit
Applications Connection Type Per Kit2-1/4" to 1/2" (57 mm to 13 mm) 21-5/8" to 1/2" (41 mm to 13 mm) 21-1/4" to 1/2" (32 mm to 13 mm) 27/8" to 1/2" (22 mm to 13 mm) 41/2" to 1/2" (13 mm to 13 mm) 127/8" to antenna, amplifier, device (22 mm to 13 mm) 121/2" to antenna, amplifier, device (13 mm to 13 mm) 12
Installation Tips
dWhenapplied,thetapemustbeabove32°F(0°C)toensureadhe-sion.Keeptapewarmbycarryingincoatpockets.
dDonotstretchthetape.Applyonlyenoughtensiontoprovideasmoothwrap.
dSmootheachwrappedlayerwithyourhandstoensurefulladhesion.
dDonotpullthetapetoteartape—alwayscutit.(Pulledtapeeventu-allyunravels,decreasingprotection.)
dAddextrafinallayersoftapeinwarmerclimateswheretherewillbelongexposuretodamagingultraviolet(UV)rays.TwoorthreeextralayersoftapewillprovideadditionalUVprotection.
dWhenwrappingtape,overlapthetapetohalf-width.
dEnsureventordrainholesatthebottomoftheantennaordevicearenotcoveredwithweatherproofingtape.
Andrew 221213 Weatherproofing Kit contains: 2rollsof3/4inx66ftblackplastictape1rollof2inx20ftblackplastictape6rollsof2-1/2inx24inbutylrubbertape
Colored Electrical Marking Tape Coloredtapeisaconvenientwaytomarkandcodecableruns.Sixdifferentcolorsareavailablein3/4inx66inrolls.Soldinindividualrolls.
Part Number Description CM-TB Blue, 3/4" x 66' (19.1 mm x 20.1 m)CM-TBR Brown, 3/4" x 66' (19.1 mm x 20.1 m)CM-TG Green, 3/4" x 66' (19.1 mm x 20.1 m)CM-TR Red, 3/4" x 66' (19.1 mm x 20.1 m)CM-TW White, 3/4" x 66' (19.1 mm x 20.1 m)CM-TY Yellow, 3/4" x 66' (19.1 mm x 20.1 m)
Standard Weatherproofing TapePart Number Description 221213 Complete kit, black221213-S Complete kit, slate gray42615-10 2-1/2" x 24" butyl rubber roll9905-41 3/4" x 66' black plastic tape roll9905-71 2" x 20' black plastic tape roll
Cable Installation Accessories
Cable Entry
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Multiple Entrance Wall/Roof Feed-Thru PlatePlatewithoneormore4or5-inchholes.Weatherproofsealingcapsincluded.Usewiththecorrespondingsizerubbercableboot(soldsepa-rately).
Part Number Number Height, Width of Openings in (mm) in (mm)
4 in (102 mm) Entry Opening, Multiple Entrance Plate
204673-1 1 7.0 (178.0) 7 (178)204673-2 1 5.0 (127.0) 5(127)204673-2A 3 9.5 (241.3) 20 (508)204673-4 4 9.5 (241.3) 25.5 (648)204673-6 6 17.5 (444.0) 23 (584)204673-8 8 17.5 (444.0) 25.5 (648)204673-9 9 23.0 (584.0) 23.0 (584)204673-10 10 9.5 (241.3) 31.0 (787)204673-12 12 25.5 (648.0) 25.5 (648)204673-16 16 25.5 (648.0) 25.5 (648204673-18 18 25.5 (648.0) 39.5 (1003)204673-20 20 28.8 (731.0) 31.0 (787)204673-24 24 31.0 (787.0) 39.5 (1003)
Hole PlugsPart Number DescriptionPLUG-12 Plug, 1/2", for unused cable boot holes, kit of 5PLUG-78 Plug, 7/8", for unused cable boot holes, kit of 5PLUG-114 Plug, 1-1/4", for unused cable boot holes, kit of 5PLUG-158 Plug, 1-5/8", for unused cable boot holes, kit of 5
Standard Cable Entry BootsUsewithfeed-thruplatewiththecorrespondingsizeentryhole.
Cable Boot Cable Number of Part Number Size Holes in Boots
4 in (102 mm) Cable Boots
204679A-17 1/4" foam 3204679A-19 3/8" foam 1204679A-5 1/2" foam 1204679A-7 1/2" foam 3204679A-6 1/2" air 1204679A-1 1/2" air 3204679A-16 1/2" 4204679A-13 5/8" 1204679A-14 5/8" 3204679A-2 7/8" 1204679A-18 7/8" 2204679A-15 7/8" 3204679A-3 1-1/4" 1204679A-4 1-5/8" 1204679A-8 2-1/4" 1204679A-9 3" 1CAP-4 Blank cap 0
5 in (127 mm) Cable Boots
48939A-16 3/8" foam 348939A-6 1/2" foam 148939A-8 1/2" foam 348939A-7 1/2" air 148939A-5 1/2" air 348939A-17 1/2" 448939A-14 5/8" 148939A-15 5/8" 348939A-1 7/8" 148939A-2 7/8" 348939A-3 1-1/4" 148939A-4 1-5/8" 148939A-9 2-1/4" 148939A-10 3" 1EP-CAP5 Blank cap 0
Single Entrance Wall/Roof Feed-Thru AssemblyIncludesrubberboot,clamp,andaluminumplate.Orderfromtable.
Part Number Cable SizeSCE-12 1/2"SCE-58 5/8"SCE-78 7/8"SCE-114 1-1/4"SCE-158 1-5/8"SCE-214 2-1/4"
ArrestorPort™ II Integrated Transmission Line Entry/Ground SystemTheArrestorPortIIintegratedbuildingentry/groundsystemredefinesthewayyouachievecableshelterentryandgrounding.Traditionalinstallationsrelyonapiecemealapproachthatstealstimeandincreasescosts.ArrestorPortIIunifiestheinstallationofentryports,ArrestorPlus®surgeprotectors,andtransmissionlinegroundingintoanintegratedentry/groundsystem.ArrestorPlussurgearrestorscutcosts,savevaluableinteriorspace,andprotectyourrevenuesandpersonnelfromthedamagingeffectsoflightningstrikes.
TheArrestorPort™IIintegratedwallentry/groundingsystemkitconsistsofanentrypanelanda1/8insolidcoppergroundbarassemblywithassemblyhardware,weatherstripping,andweatherproofsealingcapsforallentryports.UsewithArrestorPlussurgearrestors(pages37and38,orderseparately)andstandardcableboots(page22and23,orderseparately).
Part Number Description APORT-13-4 Provides mounting positions for 13 bulkhead mount surge arrestors and includes four 4" holes for waveguide entry
Cable Installation Accessories
Cable Entry
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Elliptical Waveguide—Standard Cable Entry Wall and Roof Feed-Thru and BootsA Singleentrancewall/rooffeed-thruassembly.Includesrubberboot,
clamp,andgalvanizedsteelplate.Orderfromtablebelow.
B Singleentrancewall/rooffeed-thruassemblyforEW37–EW240.Includesrubberboot,clamps,andaluminumplate.
C Waveguidebootforusewith204673and48940seriesmultipleentrancewall/rooffeed-thruplates.Bootdiameterof4inor5in(102or127mm)isavailabletomatchplate.Orderindividuallyfromtablebelow.
A, B Single Entrance Wall/Roof Feed-Thru Assemblies
Single Entrance For Waveguide Photo Size Reference Part NumberEW17 A 35849A-10EW20 A 35849A-9EW28 A 35849A-13EW37 B 245314-37EW43 B 245314-43EW52 B 245314-52EW63 B 245314-63EW64 B 245314-64EW77 B 245314-77EW85 B 245314-85EW90 B 245314-90EW127A B 245314-127AEW132 B 245314-132EW180 B 245314-180EW220 B 245314-220EW240 B 245314-240
C
B
CA
BA C
C Waveguide Boots
Part Number by DiameterFor Waveguide Size 4 in (102 mm) 5 in (127 mm)EW17 — —EW20 — — EW28 — —EW37 WGB4-37 WGB5-37EW43 WGB4-43 WGB5-43EW52 WGB4-52 WGB5-52EW63 WGB4-63 WGB5-63EW64 WGB4-64 WGB5-64EW77 WGB4-77 WGB5-77EW85 WGB4-85 WGB5-85EW90 WGB4-90 WGB5-90EW127A WGB4-127 WGB5-122EW132 WGB4-132 WGB5-132EW180 WGB4-180 WGB5-180EW220 WGB4-220 WGB5-220EW240 WGB4-240 WGB5-240
Cable Installation Accessories
Installation Aids
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
EASIAX® 2 Cable Preparation ToolsImprovesystemperformanceandcutinstallationtimewithspecial-izedEASIAX2cablepreparationtools.Wirelessinstallationspecialistsrequiretoolsthatprovideprecisionandconsistencywhenattachingconnectors.Thetoolsprovideacleancutofthecoaxialcableandeliminatecoppershavings.ThislessensthepotentialforhighVSWRandIMDreadings.EASIAX2toolsalsoreducethetimespentpreparingcableforconnectorattachmentby40%,comparedtousingcommontools.
Part Number Description CPTV2-158 Cable preparation tool for use with AL, AVA, VXL, and
LDF 1-5/8" cableCPTV2-114 Cable preparation tool for use with VXL and
LDF 1-1/4" cableCPTV2-BK Replacement blade kit for CPTV2 tools
EASIAX Replacement Blades
Tool Replacement Blade Kit
Part Number Part Number CPT-L1 CPT-BKS1CPT-F4 CPT-BKCPT-L4ARC1 CPT-BKS1CPT-E2L2DIN CPT-BKS1CPT-E2L2N CPT-BKS1CPT-L45RC CPT-BKS1CPTL6 CPT-BK6CPT-158U CPT-BK7CPT-78U CPT-BK5Recommendeddrillsizefortoolsfor1/4inthrough1/2incablesis3/8intorquevaluewith12voltminimum.Cordlessdrill14.4minimumvoltage,400–650RPM.
Recommendeddrillsizefortoolsfor7/8inthrough1-5/8incableis1/2in.Cordlessdrill15.4minimumvoltage,400–650RPM.
Fordetailedinformationoncablepreparation,seeSpecialPublicationSP50262.
Better Connections Yield Superior System PerformanceThe connector interface is one of the most critical factors affecting transmission line operation. Even experienced technicians find the job more difficult when equipped with makeshift devices or an inad-equate array of simple hand tools, and it only takes a single faulty connection to degrade performance and threaten your operation’s revenues.
EASIAX® Plus Automated Cable Preparation ToolFor Reliable Cable Preparation in 10 Seconds
Cableinstallersandsystemdesignerscandramaticallyreducecablepreparationtimeandexpensewhileimprovingoverallsystemperfor-mancewiththeEASIAXPlusautomatedcablepreparationtool.FittheEASIAXPlustooltoanystandardpowerdrill,anditremovesthecablejacket,outerconductor,andfoam,thencutsbackandchamferstheinnerconductortothecorrectdimensionsforconnectorattach-ment—allinlessthan15seconds.TheEASIAXPlusautomatedmethodofcablepreparationmeanscableconnectionsthataremoreconsistent,morereliable,andmorerepeatable.
Tool Part Number Cable Type Connector TypeCPT-L1 LDF1-50 Standard connectors
CPT-E2L2N EFX2-50 Type N connectors
CPT-E2L2DIN EFX2-50 7-16 DIN connectors
CPT-E2L2N LDF2-50 Type N connectors
CPT-E2L2DIN LDF2-50 7-16 DIN connectors
CPT-F4 FSJ4-50B FSJ4 version two connectors
CPT-L4ARC1 LDF4-50 7-16 DIN or Type N standard, RingFlare™, HL4RP-50 OnePiece™, or Positive Stop™ connectors CPT-L45RC LDF4.5-50 RingFlare connectors
CPT-78U LDF5-50A 7-16 DIN or Type N standard, RingFlare, AVA5-50 OnePiece, or Positive Stop connectors VXL5-50 AL5-50
CPTL6 LDF6-50 7-16 DIN or Type N standard, RingFlare, OnePiece, or Positive Stop connectors
CPT-158U LDF7-50 7-16 DIN or Type N standard, RingFlare, AVA7-50 OnePiece, or Positive Stop connectors VXL7-50 AL7-50
Cable Installation Accessories
Installation Aids
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Cable Types Cutting Tool Replacement Blades
Part Number Description Part Number, kit of 5 FSJ1, FSJ4, ETS1, RXL1* Series MCPT-1412 Cuts jacketing and outer conductor 209874FSJ2, FSJ4,ETS2 Series MCPT-3812 Cuts jacketing and outer conductor 209874LDF4, HL4RP-50A, RXL4** Series MCPT-L4 Cuts outer conductor and scores jacketing MCPT-BK4LDF5, VXL5, AVA5, RXL5, AL5-50 Series MCPT-78 Cuts outer conductor and inner conductor MCPT-BK5 and scores jacketingAVA5 A5MCPT-78 Cuts outer conductor and inner conductor A5MCPT-BK5
and scores jacketing
*ExceptRXL1-1RNT
**ExceptRXL4-(1,2or3)RNT
EASIAX® Cable Preparation ToolFor Fast, Precision Cuts in 15 Seconds
It’s Accurate
Cutspreciselyatcrestofcoppercorrugationattheexactdistancerequiredforeasyconnectorattachment.Cleancutmakesflaringeasierthanever.Precisebladedepthmakesitimpossibletocutinnerconductor.
It’s Consistent
Everycutbyeverytechnicianoneveryinterfaceofanycablewillbeexactlythesame.It’sonemorewaytoensureconsistentelectricalperformanceforyourcablesystem.EASIAX®precisioncuttingtoolistheonlycuttingtoolmadeexclusivelyforHELIAX®coaxialcable.
Remove2”ofjacketing
MCPT-78 Rotation
Cable Installation Accessories
Installation Aids
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Connector Attachment Torque WrenchesPreset to Andrew Specifications
AndrewtorquewrenchesattachanytypeofHELIAX®connectorstoHELIAXLDF4.5,LDF5,LDF6,LDF7,andLDF12coaxialcables.Allaredesignedwithamechanismtoaudiblynotifytheinstallerthatthepropertorquehasbeenreachedandreleasethepressure.
Part Number Cable Type Connector Type 247696 LDF4-50A OnePiece™
245154 LDF4-50A RingFlare™
244376 LDF4.5-50 RingFlare and Standard244378 LDF5-50A, OnePiece, RingFlare, AVA5-50 and Standard and VXL5-50244375 LDF6-50 RingFlare and Standard247698 LDF6-50 LDF6 OnePiece only244374 LDF7-50A OnePiece, RingFlare and Standard244374 VXL7-50 OnePiece™, RingFlare™ and Standard244373 LDF12-50 Standard244379 All Type N coupling nut244377 All 7-16 DIN coupling nut247696 LDF4-50 OnePiece
Crimping ToolUsedtoattachcrimp-onlugsforstandardandSureGround™series.Notrequiredforkitshavingfactory-attachedlugs.
Part Number207270
Aluminum Grounding Kit ToolNowinstallerscanpreparetransmissionlinecableforgroundingkitinstallationinonesimple,precisestep—andwithoutusingaknife!TheAndrewaluminumgroundingkitpreparationtooltakesjustsecondstouse:simplysnapthetoolinplacearoundthecableandrotate.Inonestepthetoolremovestheexactamountofjacketingnecessarytoattachthegroundingstrap.Thegroundingkitpreparationtoolisamanuallyoperatedcuttingdevicethatquicklytrimsawayasectionofcablejacketforthepurposeofgroundingstrapinstallation.Thetoolisidealforuseoncablesmountedclosetostructuresandothercableruns,andwillnotscrapeordamagethecable’souterconductor.
Part Number Cable Type Grounding Kit TypeGKT-F4A FSJ4 StandardGKT-L4A LDF4 Standard, CSGL, SGL,
and SGPL seriesGKT-78A LDF5, VXL5, AVA5, AL5 Standard, CSGL, SGL,
and SGPL seriesGKT-114A LDF6 Standard, CSGL, SGL,
and SGPL seriesGKT-158A LDF7, VXL7, AVA5, AL7 Standard, CSGL, SGL,
and SGPL seriesPart Number Replacement Blade KitGKT-F4A GKT-BKF4GKT-L4A GKT-BK512GKT-78A GKT-BK512GKT-114A GKT-BK67GKT-158A GKT-BK67
Cable Installation Accessories
Installation Aids
�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Description
Complete tool box kit includes all individual tools marked with an asterisk in the list below.
Manual cable preparation tool for 1/4" FSJ1-50 cableCut-off tool 7/32"Cut-off tool 8/32"Cut-off tool 9/32"
Manual cable preparation tool for 3/8" FSJ2-50 cableCut-off tool 7/32"Cut-off tool 8/32"Cut-off tool 9/32"
Automated/manual cable preparation tool for 1/2" coaxial superflexible cableManual cable preparation tool for 1/2" superflexible FSJ4-50B cable
Chamfer toolCut-off tool 7/32"Cut-off tool 8/32"Cut-off tool 9/32"
Automated/manual cable preparation tool for 1/2" coaxial cable21 mm torque wrench for L4 OnePiece™ connectors3/4" torque wrench for L4 RingFlare™ connectorsManual cable preparation tool for 1/2" LDF4-50A cable
Aluminum grounding kit stripping tool for LDF4 cableReplacement blade kit for grounding kit stripping tool for LDF4 cable
Manual cable preparation tool for 7/8" cableAutomated cable preparation tool for 7/8" cable1-1/4" torque wrench for 7/8" connectors1 -3/8" open end wrench for OnePiece™ 7/8" connectors, fits body of Positive Stop™ connectors1-1/4" open end wrench for 7/8" connectors, fits clamping nut of Positive Stop connectors Aluminum grounding kit stripping tool for 7/8" cableReplacement blade kit for plastic grounding kit stripping tool for 7/8" cable
Tool Part Number
TB-COMP-KIT
*MCPT-1412 224361 224362 244494
MCPT-3812 224361 224362 244494
CPT-F4
MCPT-1412
241953 224361 224362 244394
CPT-L4ARC1
247696 245154 MCPT-L4
GKT-L4A GKT-BK512
*MCPT-78 CPT-78U 244378 245516
244459-5
GKT-78AGKT-BK512
Cable Size
General Purpose
1/4"
3/8"
1/2" – F4
F4 and L4
1/2" – L4
7/8"
Attachment Tool KitsEasier Connections
Theconnectorinterfaceisoneofthemostcriticalfactorsaffectingtransmissionlineoperation.Evenexperiencedtechnicianscanhaveahardtimewhenequippedwithmakeshiftdevicesoraninadequatearrayofsimplehandtools,anditonlytakesasinglefaultyconnectiontodegradeperformanceandthreatenyouroperation’srevenues.
Selection
Thetableisdesignedtohelpyouselecttherighttoolsforeachcablesize.Undereachcablesizeyouwillfindalistofpartnumbersfortheappropriatecablepreparationtools,cableconditioningtools,spannerandtorquewrenches,andgroundingkitpreparationtools.
You’llhavetheoptionofselectingamanualorautomatedcablepreparationtool.Undertheindi-vidualtoolsyouwillfindthetorquewrenchesfortheconnectorinterfacenuts.
*This tool is included in the complete tool kit box, TB-COMP-KIT.
Cable Installation Accessories
Installation Aids
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Description Manual cable preparation tool for 1-1/4" cableReplacement blade for CPTV2-114Automated cable preparation tool for 1-1/4" LDF6 cable1-7/8" torque wrench 1-1/4" standard or RingFlare™ connectors 1-3/4" torque wrench for 1-1/4" OnePiece™ connectorsAluminum grounding kit stripping tool for 1-1/4" cableReplacement blade kit for grounding kit stripping tool for 1-1/4" cable 1-7/8" open end wrench
Manual cable preparation tool for 1-5/8" cableReplacement blade for CPTV2-158Automated cable preparation tool for 1-5/8" cable2-1/4" torque wrench for 1-5/8" connectors2-1/4" open end wrench for 1-5/8" connectorsAluminum grounding kit stripping tool for 1-5/8" cableReplacement blade kit for grounding kit stripping tool for 1-5/8" cable
Type N coupling nut torque wrench 7-16 DIN coupling nut torque wrenchSafety knifeRulerGrease brushPoint filePin alignment toolCable flare tool LDF4Cable flare tool LDF5Cable flare tool LDF6Pin depth gauge, Type N malePin depth gauge, Type N femalePin depth gauge, 7–16 DIN malePin depth gauge, 7–16 DIN female
Tool Part NumberCPTV2-114 CPTV2-BK CPTL6 244375 247698 GKT-114A GKT-BK67 244459-6
CPTV2-158 CPTV2-BK CPT-158U 244374 244459-7 GKT-158A GKT-BK67
244379 244377 *224352 *224354 *224355 *224356 *224360 *224363 *224368 *224373 *224380 *224395 *114468 *114469
Cable Size1-1/4" cable
1-5/8"
Individual Tools
*This tool is included in the complete tool kit box, TB-COMP-KIT.
LIGH
TNIN
G PRO
TECTIO
N
( Grounding Kits
( Grounding Bars
( Surge Arrestors
Lightning Protection
Grounding Kits
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0
Grounding Point 1
Grounding Point 4(Runs longer than 200 ft)
Grounding Point 2
Grounding Point 3
Transmission Line GroundingA well designed system uses grounding kits to provide a bond between the cable and the tower/earth ground system. One grounding kit is recommended at tower top, tower bottom, at 200 ft (60 m) intervals (where applicable), and at the entrance to the equipment shelter. Andrew solid copper grounding kits have passed United States Air Force lightning simulation tests and meet MIL-STD-188-124A. The non-braided solid copper construction of all Andrew grounding kits eliminates corrosion caused by moisture retention and “wicking.” A heat shrink tube protects the cable terminal connection.
(CompactSureGround™ (SureGround™ (Standard
Grounding Kit SelectionSeveral grounding kit options are available to meet the requirements of any transmission line grounding application.
dCompact SureGround™ grounding kits provide the fastest, easiest installation with the highest degree of lightning protection. Their self-sealing design clips and locks onto the cable in less than a minute.
dSureGround grounding kits, an industry favorite, offer clip on attachment with taped weatherproofing.
dStandard grounding kits provide the best grounding solution for elliptical waveguide. The copper grounding strap is coiled around the cable and weatherproofed with tape.
dUniversal grounding kits can be applied to a broad range of coaxial or elliptical transmission lines.
Grounding Kit Selection Guide
Compact SureGround SureGround Standard UniversalKey Feature Over-molded weatherproof Preformed clip-on strap Wraparound grounding strap Multiple cable size design for easy, fast installation wraparound grounding strapBenefits Uniform installation compact Requires no tools Fits standard coaxial cable Breakaway design fits design for bundled installation for installation and elliptical waveguide multiple sizes of coaxial cable and elliptical waveguideInstallation Time Less than 1 minute About 3 minutes About 6 minutes About 7 minutesConstruction Preformed copper Pre-tensioned copper Copper grounding strap Copper grounding strap grounding strap grounding clip Over-molded weatherproof Standard weatherproofing Standard weatherproofing Standard weatherproofing boot, locking bail
Heavy Duty Ground Lead
Andrewgroundingkitsuseheavyduty6gaugegroundleadstomaximizeperformance.TheMIL-STD-188-124Bcompliantcoppergroundleadreducesdcresistance.Theextremelypliablejacketprovidesprotectionandmakesiteasytomaneuvertheleadintopositionforattachmenttothedownconductor.
dSolidcopperconstructionforhighcurrenthandlingcapability,compatibilitywithcoppercableouterconductors
dMeetsmilitarystandardsatcommercialprices.
dProvidescertaintyofcontinuedoperation,testedatanindependentlaboratory
Lightning Protection
Grounding Kits
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
NEW! Compact SureGround™ Grounding KitsNowwirelesscommunicationssysteminstallersanddesignerscanprotecttheirsystemsfromtheeffectsoflightningeasierandatlowercost.ThenewCompactSureGroundgroundingkit,availableonlyfromAndrew,isaone-piecegroundingassemblywiththeweatherproofingmoldedrightintothegroundingstrap.
CompactSureGroundgroundingkitfeatures:
Easy attachment
dSelf-locking,self-sealingweatherproofenclosureeliminatesloosehardwareandtaping
dSavesuptoanhourofinstallationtimepertypicalninerunsite
Sure protection
dLargestsurfacecontactareaintheindustry
dProvidessuretyofprotectionagainsteventhemostseverelightningstrikes
dWaterprooftoIEC529,IP68
Compact size
d“Clipandlock”installationidealfortightcablebundlesorcrowdedtowers
dExclusiveuniversalgroundinglugcanbefittedtoaone-ortwo-holeearthingattachmentpoint.
UnitedStatesPatent:6,548,762.Otherpatentspending.
More Information
dSeeCompactSuregroundorderinginformationonpage33
dSeetheinstallationvideoatwww.andrew.com/products/trans_line/heliax/sureground.aspx
Easy Installation
PositionCompactSureGroundgroundingkit
Clipandlocktoseal
SureGround™ KitsFast Installation, Complete Protection
ProtectyourequipmentfromtheeffectsoflightningwithSureGroundgroundingkits.MeetingbothMILandIECstandards,theSureGroundself-securinggroundstrapeliminatestheneedforattachmenttoolsandprovidesprotectionagainstlightningstrikesinexcessof100kA.Qualitynon-braidedsolidcopperconstructionpreventsmoistureretentionandwicking,whileaheavyduty6gauge,MIL-STD-188-124Bcompliantcoppergroundleadmaximizesperformance.Installationisfast,easy,anderror-free.Groundingkitsincludeasolidcopperstraprivetedtothegroundingwire,towerattachmenthardware,andatwo-parttapeweatherproofingsystem.Groundingkitversionsareavailablewithatinplatingforcompatabilitywithaluminumcables.UnitedStatesPatent:5,850,056.
The Compact SureGround Kit with integrated weatherproofing is the choice for the speediest installation, best fit in tight locations, and long-term protection.
TIP!
TIP!
Completed
Lightning Protection
Grounding Kits
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Connector Grounding Kit for Mounting RailPart Number DescriptionCGT12 Connector grounding kit fits all F4 and L4 (except OnePiece™)
series connectorsCGT58 Connector grounding kit fits all L4.5 and L5
standard connectorsCGT78 Connector grounding kit fits all L5, V5, A5, OnePiece,
and Positive Stop™ series connectorsCGT114 Connector grounding kit fits all L6 series connectorsCGT158 Connector grounding kit fits all L7 and V7
series connectorsCGT214 Connector grounding kit fits all L12 series connectors
40 mm x 22 mm x 17 mm
Universal Grounding LugsThisgroundinglugprovidesyouwiththeoptionofaone-holeconfigurationortwo-holeconfiguration.Justbreakawaythebottomportionofthelugandthiswillgiveyouyourone-holelug.Thisuniversallugwillfitcommonbussbarconfigurationswithtwo-holespacingsof0.750,0.815,or1.0in.Designedtocrimpon6gaugeor16mm2groundingwire.Includedonallgroundingkitsandavailableseparately.
Part Number Description 245529-10 Universal grounding lug, kit of 10 207136-3 Grounding lug hardware kit
Standard Grounding KitsEasy Installation for System Protection
Standardgroundingkitsaretraditionalsolutionsforlightningprotectionandarealsowellsuitedforellipticalwaveguideinstallations.Onegroundingkitisrecommendedatthetowertop,towerbottom,at200ft(60m)intervals,andattheentrancetotheequipmentshelter.Standardgroundingkits(204989and241088series)requirefewstepstoinstallandincludeeasy-to-followinstructions.Propertensioningisensuredbyanexpansionsectionthatprovidesvisualindicationthatthestrapissecured.
Series204989and241088kitsincludeasolidcopperstraprivetedtothegroundingwire,coilingtoolforpropertightening,universalgroundinglug,towerattachmenthardware,andatwo-parttapeweath-erproofingsystem.Field-attachable,crimp-ongroundinglugsrequireacrimpingtool(notincluded).
Fortwoboltgrounding
Snapoffpre-scoredlugforoneholeoption
Foroneboltgrounding
Crimping Tool for SureGround™ and Standard Grounding Thecrimpingtoolisusedtoattachcrimp-onlugsforstandardandSureGroundseriesgroundingkits.Notrequiredforkitswithfactoryattachedlugs.
Part Number Description 207270 Crimping tool, quantity 1
Universal Grounding KitPart Number DescriptionUG12158-15B4 1/2"–1-5/8" EW180–EW63 60" field attached lug
Lightning Protection
Grounding Kits
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Compact SureGround™
24 in 36 in 60 in
Size/Type 600 mm 1 meter 1.5 meters factory attached lug field attached lug
1/2" LDF4 black CSGL4-06B2 CSGL4-10B2 CSGL4-15B41/2" LDF4 gray CSGL4-06S2 CSGL4-10S2 CSGL4-15S47/8" black CSGL5-06B2 CSGL5-10B2 CSGL5-15B47/8" gray CSGL5-06S2 CSGL5-10S2 CSGL5-15S41-1/4" black CSGL6-06B2 CSGL6-10B2 CSGL6-15B41-1/4" gray CSGL6-06S2 CSGL6-10S2 CSGL6-15S41-5/8" black CSGL7-06B2 CSGL7-10B2 CSGL7-15B41-5/8" gray CSGL7-06S2 CSGL7-10S2 CSGL7-15S4
SureGround™
Size/Type 600 mm 1 meter 1.5 meters factory attached lug field attached lug
1/2" LDF4 black SGL4-06B2 SGL4-10B2 SGL4-15B41/2" LDF4 gray SGL4-06S2 — —5/8" black SGL45-06B2 SGL45-10B2 SGL45-15B47/8" black SGL5-06B2 SGL5-10B2 SGL5-15B47/8" gray SGL5-06S2 — —7/8" aluminum cable SGL5-06B2-T — SGL5-15B4-T1-1/4" black SGL6-06B2 SGL6-10B2 SGL6-15B41-1/4" gray SGL6-06S2 — —1-5/8" black SGL7-06B2 SGL7-10B2 SGL7-15B41-5/8" gray SGL7-06S2 — —1-5/8" aluminum cable SGL7-06B2-T — SGL7-15B4-T2-1/4" SGL12-06B2 SGL12-10B2 SGL12-15B4
Standard Grounding Kit
Size/Type 24" in 36" in 60" in factory attached lug field attached lug
1/4" and 3/8", EW240, EW380 223158-2 223158-3 223158-41/2", EW180, EW220 241088-1 241088-6 2415455/8" and 7/8", EW85, EW90, EW127A, EW132 241088-2 241088-7 2204971-1/4", EW64, EW77 241088-3 241088-8 241088-601-5/8", EW52, EW63 241088-4 241088-9 220498EW43 204989-10 241088-64 204989-282-1/4" and 3", EW28, EW37 241088-5 241088-10 223700-7244", EW17, EW20 204989-6 — —
Universal Grounding Kit
Size/Type 60" field attached lug
1/4"–5/8" (Cinta™, HELIAX®) — — GK-SUNV
Universal Connector Grounding Kit
Part Number Description
244495 Universal connector grounding kit
Lightning Protection
Grounding Bars
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Ground Buss BarsAndrew offers a complete range of grounding buss bar sizes and hole pattern configurations to accommodate just about any application. Each grounding bar is made from 1/4 in solid copper bar stock and is available with optional tin plating. Kits come complete with insulators, stainless steel brackets, adapters, and hardware for mounting to a wall or tower.
2" Ground Buss Bar Kits Part Number Description
2" x 10" Ground Buss Bar Kits
Bare Copper
UGBKIT-0210 Universal ground buss bar kit, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm) with universal buss bar hardware kit
Tinned Copper
UGBKIT-0210-T Universal tinned ground buss bar kit, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm) with universal buss bar hardware kit
2" x 12" Ground Buss Bar Kits
Bare Copper
UGBKIT-0212 Universal ground buss bar kit, 1/4" x 2" x 12" (6.4 mm x 50.8 mm x 304.8 mm) with universal buss bar hardware kit
Tinned Copper
UGBKIT-0212-T Universal tinned ground buss bar kit, 1/4" x 2" x 12" (6.4 mm x 50.8 mm x 304.8 mm) with universal buss bar hardware kit
7/16" x 5/8"(11.1 mm x 15.9 mm)
7/16"(11.1 mm)
2" (50.8 mm)
1/2"(12.7 mm)
3/4"(19.1 mm) 10"
(254 mm)
7/16"(11.1 mm)
12"(304.8 mm)
2"(50.8 mm)
1/2"(12.7 mm)
2" x 14" Ground Buss Bar Kits
Bare Copper
UGBKIT-0214 Universal ground buss bar kit, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm) with universal buss bar hardware kit
Tinned CopperUGBKIT-0214-T Universal tinned ground buss bar kit, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm) with universal buss bar hardware kit
2-1/2" Ground Buss Bar Kits Part Number Description
2-1/2" x 12-1/2" Ground Buss Bar Kits
Bare Copper
UGBKIT-2 Universal ground buss bar kit, 1/4" x 2-1/2 x 12-1/2 (6.4 mm x63.5 mm x 317.5 mm) with universal buss bar hardware kit
Tinned Copper
UGBKIT-2T Universal tinned ground buss bar kit, 1/4" x 2-1/2" x 12-1/2" (6.4 mm x 63.5 mm x 317.5 mm) with universal buss bar hardware kit
13/16"(20.6 mm)
7/16"(11.1 mm)
1-1/4" (31.8 mm)
1-3/8" (34.9 mm)
12-1/2" (317.5 mm)
1" (25.4 mm)
1" (25.4 mm)
2-1/2" (63.5 mm)
7/16"(11.1 mm)
1/2"(12.7 mm)
2" (50.8 mm)
14"(355.6 mm)
3/4" (19.1 mm)
7/16" x 5/8"(11.1 x 15.9 mm)
(UGBKIT
Lightning Protection
Grounding Bars
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
2-1/2" x 19-1/2" Ground Buss Bar Kits
Bare Copper
UGBKIT Universal ground buss bar kit, 1/4" x 2-1/2" x 19-1/2" (6.4 mm x 63.5 mm x 495.3 mm) with universal buss bar hardware kit
Tinned Copper
UGBKIT-T Universal tinned ground buss bar kit, 1/4" x 2-1/2" x 19-1/2" (6.4 mm x 63.5 mm x 495.3 mm) with universal buss bar hardware kit
4" Ground Buss Bar Kits Part Number Description
4" x 12" Ground Buss Bar Kits
Bare Copper
UGBKIT-0412 Universal ground buss bar kit, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm) with universal buss bar hardware kitTinned Copper
UGBKIT-0412-T Universal tinned ground buss bar kit, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm) with universal buss bar hardware kit
7/16"(11.1 mm)
12"(304.8 mm)
4" (101.6 mm)
1/2" (12.7 mm) 3/4" (19 mm)
7/16" x 5/8"(11.1 mm x 15.9 mm)
7/16"(11.1 mm)
13/16"(20.6 mm)
2-1/2"(63.5 mm) 1" (25.4 mm)
1-3/8" (34.9 mm)
19-1/2"(495.3 mm)
1-1/4" (31.8 mm)
4" x 14" Ground Buss Bar Kits
Bare Copper
GBKIT-0414 Universal ground buss bar kit, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm) with universal buss bar hardware kit.
Tinned Copper
UGBKIT-0414-T Universal tinned ground buss bar kit, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm) with universal buss bar hardware kit.
(11.1 mm)
(355.6 mm)
(12.7 mm)(12.7 mm)
4" (101.6 mm)
1-1/2" (38.1 mm)
(6.4 mm)(11.1 mm x 15.9 mm)
(UGBKIT-0210
(UGBKIT-0412
Lightning Protection
Grounding Bars
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
4" x 20" Ground Buss Bar Kits
Bare Copper
UGBKIT-0420 Universal ground buss bar kit, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm) with universal buss bar hardware kit.
Tinned Copper
UGBKIT-0420-T Universal tinned ground buss bar kit, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm) with universal buss bar hardware kit.
4" x 24" Ground Buss Bar Kits
Bare Copper
UGBKIT-0424 Universal ground buss bar kit, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm) with universal buss bar hardware kit.
Tinned Copper
UGBKIT-0424-T Universal tinned ground buss bar kit, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm) with universal buss bar hardware kit.
7/16" x 5/8"(11.1 mm x 15.9 mm)7/16"
(11.1 mm)
4" (101.6 mm)
20"(508 mm)
3/4"(19 mm)
1-3/4"(44.5 mm)
7/16" x 5/8"(11.1 mm x 15.9 mm)7/16"
(11.1 mm)
4" (101.6 mm)
20"(508 mm)
3/4"(19 mm)
1-3/4"(44.5 mm)
Universal Arrestor Ground Bar AssemblyThispre-punchedsolidcoppergroundbarassemblysimplifiesmountingandgroundingofsurgearrestorsinsidethebuilding.Insteadofrelyingonindividualwiresorfield-fabricatedtrapezesetups,theAndrewuniversalarrestorgroundbarassemblyprovidesauniformmountingandgroundingpointforsurgearrestorsandgroundingleads.The1/8inassemblyusesthreehorizontalmembersthatcanbeorientedflatoruprightandadjustedverticallyasneededtoaccommodatevarioussurgearrestortypes.Alsoincludedisamountingkitthatincludesceilingbrackets,insulators,threadedrod,andhardware.
dCompatiblewithstandardentryportsizes
dHeight-adjustablebars
dSolidcopperconstruction
dAcceptsbulkheadorboltgroundedsurgearrestors
dAccommodatesone-andtwo-holegroundinglugs
dEliminatesneedforinternalbussbar
Part Number DescriptionUGBA-DIN-36 Three 6-position ground bars punched for oversized
7-16 DIN mount arrestors (APTL and APT series) or bolt-grounded arrestors
UGBA-36 Three 6-position ground bars punched for most 7-16 DIN, Type N or bolt-grounded arrestors (Andrew APG and APM series arrestors)
UGBA-DIN-34 Three 4-position ground bars punched for oversized 7-16 DIN mount arrestors (APTL and APT series) or bolt-grounded arrestors
UGBA-34 Three 4-position ground bars punched for most 7-16 DIN, Type N, or bolt-grounded arrestors (Andrew APG and APM series arrestors)
Lightning Protection
Surge Arrestors
�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
T-SeriesDualBand
dcPassDualBand
ReplaceableGasTube
dcBlockIntegrated BiasTee
T-Series Surge Arrestors ArrestorPlus®T-seriessurgearrestorsgiveengineersmoreflex-ibilitywhenconfiguringlightningprotectionsystems.Thisslimprofilearrestorfitseasilyinsideequipmentenclosures,isbi-directional,andofferstruemultistrikeprotection.ThearrestorplusbulkheadmountT-seriesfeaturesuniversalTypeNand7-16DINinterfaces.Thedcpassingversionallowscurrenttotraveltothetopofthetower.
Arrestor Plus® Lightning Surge Arrestors Add the final measure of protection to your equipment from lightning current traveling down the transmission line with Arrestor Plus surge arrestors. All designs are completely weatherproof and feature low return, insertion loss, and low intermodulation. Our wide range of surge arrestor types and configurations support most applications.
Replaceable Gas Tube Surge ArrestorsOfferingbroadbandperformancefrom0–2200MHzandexcellentelec-tricalcharacteristics,ArrestorPlusreplaceablegastubesurgearrestorsareeasytoinstall,arebidirectional,andfeaturedcpasscapabilitythroughthecenterconductortotheactivetowertopelectronics.Theunit’sremovablecapmakesperiodicmaintenancefastandeasy.
45–2200 MHz, 90 VAPG-BDFDF-090APG-BDFDM-090APG-BNFNF-090APG-BNFNM-090
45–2200 MHz, 350 VAPG-BDFDF-350APG-BDFDM-350APG-BNFNF-350APG-BNFNM-350
824–960 MHz and 1710–2170 MHz
APT-DFDF-DBAPT-DFDM-DBAPT-BDFDF-DBAPC-BDFDM-DBAPT-BDFDM-DBAPT-NFNF-DBAPT-NFNM-DBAPT-BNFNF-DBAPT-BNFNM-DB
824–960 MHz and 1710–2170 MHz dc Passing
APTDC-BDFDF-DBAPTDC-BDFDM-DBAPTDC-BNFNM-DB
380–520 MHz
APC-BDFDM-450
675–825 MHz
APC-BDFDM-700
2000–2800 MHz
APB-BNFNF-2400
Bias Tee Andrewbiasteesaredesignedtoprotectequipmentfromdamagingtransientsinducedbylightningstrikes.Thisproductallowstheinjec-tionofdccurrenttothecenterconductorofthefeederline,allowingcurrenttotraveltothetopofthetower.Biasteesareunidirectionaldevices.Portsareclearlymarkedtoshowmountingdirectionwitheither“Antenna”or“Radio”.
824–960 MHz and 1710–2170 MHzABT-DFDM-ADBHABT-DFDM-DBABT-DMDF-ADBHABT-DMDF-DBABT-NFNM-DBABT-NMNF-DB
dc BlockThedcblockisdesignedtoblockdcsignalsfrompassingthroughthecenterconductorofacoaxialtransmissionline.Thedcblockisabidi-rectionalRFdevice.EitherRFportmaybeconnectedtotheequipmentsideortheantennasideofthetransmissionlineinterfacetoprovideequivalentprotection.
824–960 MHz and 1710–2170 MHzADCB-DFDM-DB
Integrated Surge Arrestor/ConnectorTheArrestorPlus®integrated,T-serieslightningsurgearrestorisaone-piecesurgearrestor/HELIAX®connector.Ituniquelycombinesthereli-abilityofquarterwaveshortingstubtechnologywiththeprovenperfor-manceofHELIAXconnectorstodeliverpremiumlightningprotectioninasinglecomponent.
824–960 MHz and 1710–2170 MHzAPTA5DC-BDF-DBAPTA7DC-BDF-DB
Surge Arrestor AccessoriesPart Number DescriptionGASTUBE-090 90 volt gas tube replacement, kit of 10GASTUBE-350 350 volt gas tube replacement, kit of 10243951 90 degree mounting/grounding bracket, Type N243950 90 degree mounting/grounding bracket, 7–16 DIN244847 Integrated surge arrestor/connector 90 degree
mounting/grounding bracket, 7–16 DINDF-CAPKIT Plated port sealing cap, 7–16 DIN (Fits onto DIN female
connector), IP 66 and 68
Lightning Protection
Surge Arrestors
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
APPEN
DIXES
Appendix �
Quarterwave Stub Surge Arrestors
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0
Quarterwave Stub Surge Arrestors—Considerations and SelectionQuarterwave Stub (QWS) Surge Arrestor Technology
Anunderstandingofthekeyconceptsofquarterwavestubtech-nologyanditsrelationshiptolightningtransientscanbeofgreatbenefittotransmissionlinesystemdesignersandoperators.Withthisunderstanding,systemdesignersandoperatorscanmorefullyutilizelightningprotectionsystemsthatuseQWStechnologyaswellasunderstandthecriticalrolemultistrikeabilityplaysinlight-ningprotectionsystems.
ArrestorPlus®T-seriessurgearrestorsfromAndrewCorporationemployQWStechnology,auniquedesignthatallowsmicrowavesignalstopassunattenuatedwhileshuntingthelowerfrequenciesassociatedwithlightning-inducedtransientstoground.ThisprovenQWStechnologyisutilizedinAPTArrestorPlus®SurgeArrestors.
TounderstandQWStechnology,oneneedstounderstandlightning.Thelightningtransientischaracterizedbyacurrentwaveformwithan8-microsecondrisetime(timetoreach90%ofthepeakvalue)anda20-microseconddecaytime(timetodecayto50%ofthepeakvalue).Peakcurrentscanreachexcessivevalues,but50%ofallstrikeswillreachvaluesofonly18kA.Itisimportanttorememberthatthisisonlyalaboratorycharacterizationofthelightningtransient,butitfacilitatesstandardizedtestingtechniquesfortheindustry.Figure1depictsanactuallaboratory-generated8/20µsecwaveformthatwasusedtoevaluateAndrewsurgearrestors.Formoredetailedinformationregardinglaboratorygeneratedsurgewaveforms,seeIEC60-2,ANSI-IEEEStd4-1978,andANSIC62.1-1984.
Thesubstantialenergyassociatedwithlightningtransientshasfrequencycomponentsneardcwithcomponentsofdecreasingvalueofenergyextendingthrough160kHz.
Theeffectivenessofsurgearrestorsischaracterizedbythethroughputenergyandtheabilitytowithstandmultiplesurges.Thesecharacteristicsarereadilymeasurableinalaboratoryequippedwiththeappropriatetestequipment.Throughputenergyisameasureoftheamountofenergypassedthroughtheoutputofthedevicewhentheinputofthedeviceissubjectedtoalight-ningtransientwaveform.Thethroughputenergycanbecalculatedfromtheresidualvoltagewaveformusingtherelationship:
Figure2showstheresidualoutputvoltagepresentwhenanAPTSeriesSurgeArrestorwassubjectedtoanactual8/20µsecwaveformwithapeakcurrentof20kA.Inthiscase,theresidualvoltagewasrecordedacrossa50ohmload.Theresultingthroughputenergywas72microjoules.Theobjectiveofthesurgearrestoristominimizethethroughputenergytoamanageablelevel.Mostmicrowavetransmittersandreceiversusedintoday’swirelesssystemsarecapableofwithstandingthroughputenergylevelsof10millijoulesorless.
Theabilitytowithstandmultiplestrikesisalsoanimportantmeasureofsurgearrestormerit.MultistrikeabilityismeasuredbysubjectingtheQWSsurgearrestorstorepeatedsurgesandobservingifthearrestorscontinuetoproperlyfunctionorshow
Time (microseconds)Figure 1
Time (microseconds)Figure 2
Laboratory generated 8 x 20 µsec lightning surge current waveform.Peak current: 21 kiloamperes
Residual output voltage of an APT quarterwave stub surge arrestor when subjected to an 8 x 20 µsec current surge with peak current of 20,000 amperes.
Appendix �
Quarterwave Stub Surge Arrestors
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
signsofdegradation.NoevidenceoffailureordegradationwasobservedaftersubjectingtheAndrewArrestorPlus®surgearres-torstoover100strikesat50kApeakcurrentusingan8/20µsecwaveform.Thislevelofreliabilityisessentialinprotectingtoday’stelecommunicationssystemsfromthepotentialofdamaginglight-ningtransients.
ArrestorPlusQWSsurgearrestorsarecarefullydesignedandtestedtoprovidealowimpedancepathtogroundforanylightninginducedtransientenergypresentonthecenterconductorofthetransmissionline.Thesesurgearrestorsaredesignedtowithstandmultiplestrikesofthemostseveresurges.TheuniqueattributesofQWSsurgearrestorsaremadepossiblebycarefuldesignandselectionofthegeometryandcross-sectionalareaoftheconductorsthatmakeuptheshortingstub.QWSdesignsresultinextremelylowthroughputenergydeviceswithtruemultistrikeability.
Whenselectingasurgearrestor,theRFperformancemustbeconsidered.CharacteristicsthatdescribeRFperformanceareoperatingbandwidth,VSWR(returnloss),insertionloss,maximumaveragepower,andpassiveintermodulationdistortion.
Theoperatingbandwidthofquarterwaveshortedstubsislimited,butAndrewArrestorPlusQWSsurgearrestorsaredesignedtoaccommodatetheoperatingbandwidthrequirementsoftoday’swirelesstelecommunicationssystems.Quarterwaveshortedstubscanbedesignedtoaccommodateupto20%bandwidth.Thebandwidthcharacteristicsofthesurgearrestorsissimilartothatofabandpassfilter:RFsignalsatthecenterofthebandpassunat-tenuated,whileout-of-bandsignals(suchaslightningtransients)aredivertedharmlesslytoground.
Figure3showsthemeasuredwidebandS11(returnloss)ofaQWSsurgearrestor.Notethatinthebandofinterest,theS11levelsaretypically-30dB.
Itiskeytonotethatdcsignalscannotbepassedthroughthedevice.Whendcpassingisrequired,asisoftenthecasefortowertopactiveelectronics,thenitisstronglyrecommendedtouseAndrewAPGgastubeseriessurgearrestors.FormoreinformationonAPGgastubeseriesarrestors,seeAppendix2.
Thelowestcenterfrequencyofoperationislimitedtoapproxi-mately400MHz,whilethehighestcenterfrequencyislimitedbythecutofffrequencyofthecoaxialcablebeingused.Figure4showsacross-sectionalviewofaQWSsurgearrestor.Theloweroperatingfrequencyislimitedduetothephysicalsizeoftheshortingstub.Whentheshortingstubreachestoolongofaphysicallength,thestubappearsasaninductiveload,resultinginexcessiveresidualvoltages.Quarterwaveshortedstubscanbedesignedtoaccommodatesystemsoperatingashighas12GHz.
Frequency (MHz)Figure 3
Figure 4
S11 vs Frequency for a QWS surge arrestor
IntheoperatingbandwidthoftheArrestorPlus®QWSsurgearrestors,theRFperformancecharacteristicsareoptimal.AttheoperatingfrequenciesoftheArrestorPlus,theinsertionlossislessthan0.1dB,nomorethanaddingaconnectortothetransmissionlinepath.Figure5showsthemeasuredS21(insertionloss)perfor-manceofanAPMtypeQWSsurgearrestor.Notethatinthebandofinterest,theS21levelsarebetterthan-0.05dB.
ThemaximumaverageoperatingpoweroftheArrestorPlusQWSsurgearrestorislimitedbytheconnectorinterface.ThesuggestedmaximumaverageoperatingpowerforTypeNconnectorsis600wattsat900MHz.Thesuggestedmaximumaverageoperatingpowerfor7-16DINconnectorsis3000wattsat900MHz.Exceedingthesevaluescanresultinexcessivetemperatureriseandpermanentdamagetothedevice.
Intermodulationdistortion(IMD)isamajorconcernintoday’sPCS,cellular,ESMR,andotherwirelesssystems.IMDiscausedbynonlineareffectswithinadevice.Forconnectors,thesenonlineareffectscanbecausedbypoorcontactbetweeninternalsurfaces,platingwithferrousmaterials,suchasnickel,orbyoxidebuildupbetweencontactsurfaces.
Appendix �
Quarterwave Stub Surge Arrestors
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
ArrestorPlus®surgearrestorsaredesignedwithhighpressurecontacts,premiumplatings,andarecompensatedtoofferthebestpossibleIMDperformance.
ThefunctionalityofArrestorPlusQWSsurgearrestorscanbereadilyevaluatedbyusingordinaryRFfieldtestequipment.IfthereisnodegradationoftheVSWRorinsertionlossofthearrestor,thenthesurgearrestorisreassuringlyfunctioningasatransientlightningprotectiondevice.VSWRandinsertionlossmeasurementscanbemadebyusingvectororscalarnetworkanalyzersaswellasavarietyofotherreadilyavailablefieldtestequipment.Noothermaintenanceisrequired.Asobviousasitmayseem,surgearres-torsshouldneverbeinstalledortestedwhenastormisoccurringorapproaching.
Systemrequirementsoftendictateoutdoorinstallationofsurgearrestors.ArrestorPlussurgearrestorsareidealfortheseapplica-tionsanddesignedtowithstandtheharshestenvironmentsandareextensivelytestedtomeetindustrystandardspecificationsforwaterproofing,vibration,thermalcycling,mechanicalshock,saltspray,fungus,andmoistureresistance.
QWSsurgearrestorsareexcellentchoicesforwirelessbasestationapplicationswheresuperiorRFperformanceisrequiredtoensurecallqualityandwhenprotectionagainstmultiplelightningstrikesisofprimaryimportance.
Frequency (MHz)Figure 5
S21 vs Frequency for a QWS surge arrestor
Appendix �
Gas Tube Surge Arrestors
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Using the Maximum Average Power Derating Curves GSM Radio Operating Conditions:
1.Numberofcarriers=22.Powerofeachcarrier(dBm)=+42dBmcarriersattheoutput
ofahybridcombiner(+45dBmatcombinerinput)3.VSWR=1.25:14.dcBias=15V5.NominalImpedance=50Ω
Gas Tube Surge Arrestors—Considerations and SelectionGas Tube Surge Arrestor Technology Tosimplifyselectingtheappropriategastubesurgearrestorforyoursystemplots,maximumaveragepowervs.VSWRhavebeencompiled.Figures1and2showplotsofmaximumaveragepowervs.VSWRfor90and350voltgastubes.Eachgraphshowsdifferentvaluesofcommonlyuseddcbiasvoltages.Thesegraphswereestablishedfromextensivelaboratorytestingandincludetheappropriatesafetyfactorstoensurepropergastubeselection.Usingthesegraphsforselectingagastubewilloptimizethelevelofprotectionrequiredforyoursystem.
Gastubeelementsareofferedinvariousspark-overvoltages.AndrewCorporationsimplifiestheselectionprocessbylimitingthechoicetotwooptions,90voltforGPSapplicationsand350voltformanyotherwirelessapplicationsrequiringadcbias.Plotsofmaximumaveragepowervs.VSWRhavebeencompiledforthe90and350voltgastubesfromextensivelaboratorytestingandhavebuilt-insafetyfactorstoensureproperselection.Seefigures3and4.Eachgraphshowsseveraldifferentvaluesofcommonlyuseddcbiasvoltages.Usingthesegraphsforselectingagastubewilloptimizethelevelofprotectionrequiredforyoursystem.
Whenworkingintoday’senvironmentofdiplexedsignals,overlaidnetworks,towermountedamplifiers,andmultiplecarriers,itisnecessarytoverifythatasystem’smaximumaveragepowerdoesnotexceedthatratingforthegastube.Thefollowingexampleillus-tratestheprocessofusingthevoltagederatingcurvesthatfollow.
1. Calculate the peak instantaneous voltage of a single +42 dBm carrier for a 50 ohm based system
AveragePower10
(averagepowerpercarrierindBm/10) perCarrier(watts)=
1000
Vrmspercarrier(volts):= √ averagepowerpercarrier(watts)•Impedance(ohms)
Vrmspercarrier(volts)=28.284
Vpeakpercarrier(volts):=√2•Vrmspercarrier(volts)
Vpeakpercarrier(volts)=40
Therefore, the peak instantaneous voltage of a single +42 dBm carrier is 40 volts.
2. Calculate the peak instantaneous voltage of a two, +42 dBm carrier, 50 ohm based system
Peakinstantaneousvoltage(volts):= Vpeakpercarrier(volts)•numberofcarriers(N)
Peakinstantaneousvoltage(volts)=80
Therefore, the peak instantaneous voltage of a two +42 dBm carriers is 80 volts.
3. Calculate the peak instantaneous power of two, +42 dBm carrier, 50 ohm based system
Peakinstantaneouspower(watts):= (Peakinstantaneousvoltage(volts))2
Impedance(ohms)
Peakinstantaneouspower(watts)=128
Peakinstantaneouspower(dBm):=
10•log
Peakinstantaneouspower(watts) 0.001
Peakinstantaneouspower(dBm)=51.072
Therefore, the peak instantaneous voltage of two, +42 dBm carriers is 128 watts (+51 dBm).
4. The gas tube selection curves are specified as Maximum Average Power vs. VSWR. Therefore, it is required to calculate an estimate of the average (RMS) power from the peak instantaneous power. A reasonable calculation of this estimate is shown below:
Peakinstantaneousvoltage(volts)=80
RMSequivalent(volts):=Peakinstantaneousvoltage(volts)
√2
RMSequivalent(volts)=56.569
RMSequalpower(watts):=(RMSequivalent(volts))2
Impedance(ohms)
RMSequalpower(watts)=64
Therefore, to utilize the gas tube selection curves, an approximate value of 64 watts average power would provide a reasonable estimate.
Note that for this calculation, the dc bias voltage was not specified and the VSWR was not specified. The gas tube selection curves provide a derating for both the VSWR and dc bias voltage.
5. Apply calculated information to the derating curves.
Appendix �
Gas Tube Surge Arrestors
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
1.25
Vdc bias 15 V
3.25 W
Steps
1.Applysystemparametersto90Vcurves.
2.Estimate15Vdcbiasline
3.Findaveragepowerlevelatintersectionwith1.25VSWR
4.Averagepower=3.25W
5.3.25Wismuchlessthan64Wtherefore90Vgastubeisnotchosenforthisapplication.
6.Moveonto350Vcurve.
Steps
1.LocatemaximumaveragepowerforsystemwithVSWR=1.25andVdc=15Vasbefore.
2.Maximumaveragepower(est.)=375W(+55.74dBm)
3.Estimatedaveragepower(fromcalculation)=64W(+48.06dBm)
4.Resultingsafetymarginis7.68dB.
5.350Vgastubeischosenduetoacceptablesafetymargin.
TheAPTDClineofdcpassingsurgearrestorsshouldbeusedforthosecaseswheretheintersectionofVSWRandMaximumAveragePowerlieabovethe0voltdcoffsetcurve.
375 W
Vdc bias 15 V
Gas Tube Derating Curves
90 VoltFigure 3
350 VoltFigure 4
VSWRFigure 1
Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 90 volt gas tubes
VSWRFigure 2
Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 90 volt gas tubes
Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 90 volt gas tubes
Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 350 volt gas tubes
Appendix �
Gas Tube Surge Arrestors
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
AndrewArrestorPlus®gastubesurgearrestorsallowfieldreplacementofgastubeelements.Gastubescanbereplacedbysimplyremovingthenutandreplacingtheelement.Agastubeelementmaynotalwaysshowoutwardsignsoffailureordegrada-tion,therefore,routinemaintenanceandinspectionissuggested.Ifthenumberofstormsinanareaishigh,gastubeelementsshouldbereplacedmorefrequently.Gastubedegradationisdependentonthenumberaswellastheintensityofthelightningstrikes.Asobviousasitmayseem,gastubeelementsshouldneverbereplacedwhenastormisoccurringorapproaching.
Whenselectingasurgearrestor,theRFperformancemustbeconsidered.CharacteristicsthatdescribeRFperformanceareoperatingbandwidth,VSWR(returnloss),insertionloss,andmaximumaveragepower.
ArrestorPlusgastubearrestorsofferthewidestbandwidthavailableofanygastubesurgearrestorsonthemarket.Unlikequarterwavestubarrestors,AndrewAPGgastubearrestorscanbeusedforapplicationsunder400MHz.Asingleunitcanbeusedforbroadbandapplicationsoverthefullfrequencyrangeof0–2000MHz.Figure5showsthemeasuredwidebandS11returnlossplotofagastubesurgearrestor.Notethatinthecommonlyused800–960MHzand1700–2000MHzbands,theS11levelsaretypicallybetterthan-30dB.
OvertheoperatingfrequenciesoftheArrestorPlussurgearrestor,theinsertionlossislessthan0.1dB,nomorethanaddingaconnectortothetransmissionlinepath.Figure6showsthemeasuredS21(insertionloss)performanceforatypicalAPGfamilyarrestor.Notethatinthecommonlyused800–960MHzand1700–2000MHzbands,theS21levelsaretypically-0.05dBand-0.12dB,respectively.
UnlikeQWSarrestors,agastubearrestorcanpassdccurrentalongthecenterconductor,asisoftenrequiredfortoday’swirelesscommunicationsystemsincorporatingtowertopactiveelectronics.
VSWRandinsertionlossmeasurementofAPGgastubesurgearrestorscanbemadebyusingvectororscalarnetworkanalyzersaswellasavarietyofotherreadilyavailabletypesoffieldtestequipment.Thearrestorsaredcpassingbroadbanddevicesandcanthereforebeusedwithtimedomainreflectmetersorfaultlocationequipment.
Systemrequirementsoftendictatethatsurgearrestorswillbeinstalledoutdoors.TheArrestorPlusAPGseriessurgearrestorsfromAndrewareidealfortheseapplicationsandaredesignedtowithstandtheharshestenvironment.Theyareextensivelytestedtomeetindustrystandardspecificationsforwaterproofing,vibration,thermalcycling,mechanicalshock,saltspray,fungus,andmoistureresistance.
AndrewArrestorPlusgastubesurgearrestorsareanexcellentchoiceforbroadbandfrequencyapplicationsorwhenadcbiasisrequiredforprovidingpowertotowertopdevices.Pleasevisitourwebsiteatwww.andrew.comformoreinformation.
S11 vs Frequency for an APG gas tube surge arrestor
S21 vs Frequency for an APG gas tube surge arrestor
Frequency (MHz)Figure 5
Appendix �
dc Passing T-Series Surge Arrestors
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
dc Passing T-Series Surge ArrestorsAndrewArrestorPlus®dcpassingsurgearrestors(USpatentpending)aretruebroadbandRFdevicesthatarecapableofallowingadcbiastopassalongthecenterwhileshortingthelowerfrequenciesassociatedwithlightninginducedtransientstotheouterconductorandtoearthground.ByremovingthegastubefromtheRFpath,theyallowdcvoltagetopassandgreatlyenhancepowerhandlingcapability.
ArrestorPlus®dcpassingwidebandsurgearrestorsarethesamegeneralshapeandsizeasatypicalquarterwavesurgearrestors.Thearrestoriscomprisedoftwocoaxialconnectorinterfacesjoinedbyacenterconductorpassingthroughacoaxialarrestorbody.Ashortingstubconnectstothecenterconductoronanaxisperpendiculartothecenterconductorthroughaportinthearrestorbody.AgasdischargetubesitsdirectlyontopoftheRFshortingstub,underconstantpressureappliedbythegastubespringclip.Theshortingstub,RFshortingstub,gastube,andgastubespringcliparesealedinsideoftheshortingstubsleeveandarrestorbodybycompressingano-ringbetweenthescrew-ingascapandtheshortingstubsleeve.
ThefunctionofthevariouselementsinthedcpassingT-seriessurgearrestordescribedabovearebestunderstoodifmodeledasasimpleelectroniccircuitasshowninfigure1,below.
Figure 1 Electronic circuit diagram of
dc-passing wideband surge arrestor
Thetwocoaxialconnectorinterfaces,portsP1andP2,providecouplingtocoaxialcablesthatrunbetweentheoutputoftheradioequipmentandthesurgearrestorandthesurgearrestorandtheantenna.Thiscableisindicatedashavinganominalimpedance(Zo)of50Ω.ThecenterconductorsectionsthatarebetweenthecoaxialconnectorinterfacesandtheshortingstubaremodeledastransmissionlinesTL1andTL2.Theshortingstubismodeledasaninductor(L1)thatconnectstothecenterconductorbetweenTL1andTL2.TheoutersurfaceoftheRFshortingstubiscoatedwithadielectricmaterialtocreateaseriescapacitance(C1)betweentheendofthehelicalshortingstubandtheshortingstubsleeve,whichisaground(G1).Agasdischargetubewithcapacitance(C2)sitsinparallelwithcapacitorC1andground(G2).Theinductance,L1,ofthehelicalshortingstubandtheeffec-tivecapacitanceofparallelcapacitorsC1andC2tunethesurgearrestorgivingitabroadbandfrequencyresponse.
Undernormaloperatingconditions,theRFsignalwillpassstraightfromP1toP2sincetheinductor,L1,appearsasanopencircuit.WhenadcbiasvoltageisappliedateitherP1orP2,itwillalsopassstraightthroughthedevice.Thedcbiasvoltageispreventedfromshortingtoeitherearthgrounds,G1orG2,bycapacitors,C1andC2,becausethesecapacitorsappearasopencircuitstolowcurrentdcbiasvoltagestypicallyappliedtopowertowermountedamplifiersoractiveantennas.Thegasinthegasdischargetubewillionizeunderlightningstrikesorotherhighvoltageconditionsallowingthetransienttogofromthecenterconductortotheouterconductororground(G2).Forpurposesofeffectivegrounding,thesurgearrestorcaneitherbemountedtogroundthroughabulkheadinterfaceorbymountingthesurgearrestortoacoppergroundingbussbarviathreadedmountinghardwarethatisprovidedwiththesurgearrestorororderedseparately.
Appendix �
Lightning Strike Probability
�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Definitions and CommentsIsokeraunic Level:Theisokerauniclevelisameasureofthenumberofthunderstormdaysperyear.Athunderstormdayisdefinedasadayonwhichthunderisheard.Forexample,thecityofChicagoaverages41thunderstormdaysperyear.Theisoke-rauniclevelisexpressedas:
Ty = Isokeraunic LevelsTotal Flash Density:Thetotalflashdensityisameasureofthenumberofflashesperyearpersquarekilometer.Forexample,thecityofChicagoaverages33flashesperyearpersquarekilometer.Totalflashdensityincludesintracloudflashes,intercloudflashes,andcloud-to-groundflashes.TotalflashdensitycanbeexpressedasDT.Theexpressionfortotalflashdensityisanempiricallydeterminedvaluebasedonmanyyearsofobservationandcanbeapproximatedasfollows:
P fraction DT ≈ 0.02 x Ty2 P fraction
Ground Flash Density:Thegroundflashdensityisameasureofthenumberofflashesthatreachtheground(asopposedtointercloudandintracloudtypeflashes).Flashesthatreachthegroundaretheonesthatarethreateningtous.Forexample,thecityofChicagoaver-ages9.9groundflashesperyearpersquarekilometer.Theexpres-sionforgroundflashdensityisanempiricallydeterminedvaluebasedonmanyyearsofobservationandcanbeexpressedasfollows:
DGround Flash = P fraction x DT
isthefractionoftotalflashesthatreachtheground.Thevalueisrelatedtothelatitudeasexpressedinthefollowingequation:
P fraction = 0.1 x [1 + (latitude)2] 30
Area of Attraction of a Structure:Astructurehasadefinedattrac-tionareathatisstronglydependentontheheightandlessdepen-dentonitswidthandlength.ForastructureofheightH,lengthL,andwidthW,theareaofattraction(sometimesreferredtoas“areaofcollection”)canbeestimatedbyusingthefollowingequation.Allunitsareinmeters.Notethatifthestructurehasasmalllengthorsmallwidthascomparedtotheheight,suchasacommunicationstowerorpole,thentheequationisdominatedbytheheight.
AreaC = L W = 4.4 H (L + W) + π (2.2 H)2
Average Number of Strikes per Year to a Tower:TheaveragenumberofstrikesperyearforanarbitrarytowerofheightH,lengthLandwidthW,canbeestimatedbymultiplyingtheAreaofAttraction,AreaC,bytheGroundFlashDensity,DGroundFlash.SincetheAreaofAttraction,isexpressedinsquaremetersandtheGroundFlashDensityisexpressedinsquarekilometers,afactorof10-6mustbeincluded.
Sψ ≈ Areac x D Ground Flash x H 2 x 10-6
Strikes per Year, 50 foot tower:Asanexample,a50-foottowerintheChicagoareawillaverage0.040strikesperyear(orthiscanbeinterpretedas1strikeevery24.6years).Thecalculationswerebasedona50-foot(15.24meters)height,3.5-meterwidth,3.5-meterlength,latitudeof42degrees,andanisokerauniclevelof41thunderstormdaysperyear.
Strikes per Year, 100 foot tower:Asanexample,a100-foottowerintheChicagoareawillaverage0.153strikesperyear(orthiscanbeinterpretedas1strikeevery6.5years).Thecalcula-tionswerebasedona100-foot(30.48meters)height,3.5-meterwidth,3.5-meterlength,latitudeof42degrees,andanisokerauniclevelof41thunderstormdaysperyear.
Strikes per Year, 200 foot tower:Asanexample,a200-foottowerintheChicagoareawillaverage0.591strikesperyear(orthiscanbeinterpretedas1strikeevery1.7years).Thecalcula-tionswerebasedona200-foot(60.96meters)height,3.5-meterwidth,3.5-meterlength,latitudeof42degrees,andanisokerauniclevelof41thunderstormdaysperyear.
Itisimportanttorememberthatthesearestatisticalcalculationsbasedonmanyyearsofobservation.Whenlightningstrikeswithinevenafewkilometersofthetower,damagingtransientscanbecoupledandcarriedonanytransmissionlines,datalines,andpowerlinesinthevicinityandcausedamagingeffectswithintheareaofthetower.References1IEC1312-1,ProtectionAgainstLightningElectromagneticImpulse2IEEEC62.41-1991,IEEERecommendedPracticeonSurgeVoltagesinLow-VoltageacPowerCircuits3MIL-STD-188-124A,MilitaryStandardforGrounding,BondingandShielding4MIL-HDBK-419A,MilitaryHandbookfortheTheoryofGrounding,BondingandShieldingof
CommunicationsElectronics.Volume1(BasicTheory),Volume2(Applications)5MIL-STD-1757A,LightningQualificationTestTechniquesforAerospaceVehiclesandHardware6NationalElectricCode1993,Article2807IEC1024-1,ProtectionofStructuresAgainstLightning.8BS6651,1992CodeofPracticeforProtectionofStructuresAgainstLightning9Aleksa,J.andStockman,C.,“AFlashofBeautyoraForceforDestruction?”,SouthAfrican
WirelessCommunications,Aug199710Fisher,F.A.andPlumer,J.A.,LightningProtectionofAircraft,LightningTechnologies,1990
Lightning Strikes—Statistics and DefinitionsStatistics on the probability of a lightning strike to towers of various heights in various locations on Earth
Isokeraunic Flash Ground Strikes per Year: Location Level Latitude Density Flash Density 50-foot tower 100-foot tower 200-foot tower
Chicago, IL 41 42 33.60 9.95 0.041 0.153 0.591Arlington, TX 48 33 46.10 9.85 0.040 0.151 0.585Atlanta, GA 50 34 50.00 11.30 0.046 0.173 0.671Tampa, FL 100 28 200.00 35.00 0.143 0.537 2.081York, UK 9 53 1.62 0.67 0.003 0.010 0.039Taiwan 20 23 8.00 1.27 0.005 0.019 0.075Hong Kong 30 23 18.00 2.85 0.012 0.043 0.170Singapore 140 2 392.00 39.30 0.160 0.604 2.340Rio de Janeiro 60 23 72.00 11.40 0.046 0.175 0.679
Appendix �
Additional Documents
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Andrew Accessory Products InformationCable Hoisting and Attachment Bulletin Number
Support/HoistingGripsforHELIAX®Cables 237409
Click-OnHangers 237397
StandardHangerKits 37378
Type31766AHangerKits 17783
HangerKits 37321
HoistingGripandCableSupportHangers SP30-45
CompactAngleAdapters 10140
AngleAdaptors(types31768A,243684,243684-M) 237363
HangerSpacingGuidelines TP-101619.1-EN
SnapStak™Adapterfor3/8"ControlCable TP-100940-EN
CableTie40417 TP-101085-EN
HoistingGripfor1/4"DataCables 7540680
SnapStak™Installation 237637
Tools
HELIAX®ConnectorToolKit 237274
WrenchKits 10234
SecuringCoaxialCableinaMonopole 10236
AndrewInstallationTools PA-100414.2-EN
Weatherproofing
3M™ColdShrink™WeatherproofingKits 237272
3M™ColdShrink™WeatherproofingKits 237426
ApplicationDetailsfor3M™ColdShrink™Kits SP50030
Connector/SpliceWeatherproofingKit 237133
WeatherShield™Enclosures PA-100428.4-EN
WeatherShield™Installation,MainFeederAntenna 750141
WeatherShield™Installation,Antenna 237914
TechnicalSpecificationsforWeatherShield™ TP-100257.2-EN
Cable Entry
CabinetFeed-ThruPlatesfor1/2"through1-5/8" 237362
Types204673and48940Wall/RoofFeedThruPlates 237060
SingleEntranceWall/RoofFeed-ThruKits 37007
ArrestorPort™IIEntry/GroundSystem 237516
Lightning Protection
UniversalGroundingBar 237440
UniversalGroundBarAssembly 237513
SureGroundInstallation 237549
StandardGroundingKits 237549
ConnectorGroundingKit 237701
CompactSureGround™Kit PA-101089-EN
CompactSureGround™TestingPerformance SP50365-A
CompactSureGround™InstallationInstruction 7513851
ThetablebelowlistsAndrewpublicationsfortheproductsmentionedinthisguide.Theyareavailableatwww.andrew.com.
Appendix �
Hanger Spacing Guidelines
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Standard Hanger—Maximum Hanger SpacingCable Size Cable Type Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" LDF4-75A 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HL4RP-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HJ4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HLT4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 3 (0.9) 2 (0.6)
1/2" HT4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HST4-50 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HS4RP-50 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" FSJ4-50B 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" FSJ4-75A 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
5/8" LDF4.5-50 42396A-9 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
5/8" HJ4.5-50 42396A-9 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" AVA5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" LDF5-50A 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" AL5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" HJ5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" HJ5-75 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" HT5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
1-1/4" LDF6-50 42396A-1 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9)
1-5/8" AVA7-50 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
1-5/8" AL7-50 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
1-5/8" HJ7-50A 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
DefinitionsandAssumptions1.PerEIA-222Standard:Coefficientofdragforcoaxialcableis1.2(cylindricalmembers).Iceformscompletelyaroundmember(360degrees).Combinedwindandiceloadingisreducedby25%toreflectlowerprobabilityofwindandiceoccurringsimultaneously.2.Windspeedsaremaximum,whichincludesgustfactorsandexposurefactors.Note:Standardtowerconfigurationspacingis3to4ft.
HELIAX® Coaxial CableRecommended maximum hanger spacings are tabulated below for various wind speed and ice conditions. The recommendations are based on guidelines stated in EIA Standard RS-222 and new wind tunnel and vibration tests. They supersede those in previous Andrew catalogs. Please refer to Andrew publication number TP-101619-EN available at www.andrew.com for the most current recommendations.
These spacing recommendations assume that all hangers are properly installed and tightened. Installations in Typical ClimatesUse the 125 mph (200 km/h), 1/2 in ice conditions, highlighted in red. Severe or Mild ClimatesUse the wind speed and ice conditions that most closely approximate the expected worst case conditions for the local climate.
Appendix �
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0
Standard Hanger—Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
2-1/4" LDF12-50A 42395A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
2-1/4" HJ12-50 42396A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice
1/2" LDF4-50A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" LDF4-75A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HL4RP-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HJ4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HLT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HST4-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HS4RP-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-50B 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-75A 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
5/8" LDF4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)
5/8" HJ4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)
7/8" AVA5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" LDF5-50A 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" AL5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HJ5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HJ5-75 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HT5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1-1/4" LDF6-50 42396A-1 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" AVA7-50 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" LDF7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" AL7-50 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" HJ7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
2-1/4" LDF12-50 42395A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
2-1/4" HJ12-50 42396A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
Note:Standardtowerconfigurationspacingis3to4ft.
Appendix �
Hanger Spacing Guidelines
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Snap-In Hanger—Recommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" LDF4-75A SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HL4RP-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HJ4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HLT4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HT4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HST4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HS4RP-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" FSJ4-50B SSH-12 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6)
1/2" FSJ4-75A SSH-12 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6)
5/8" LDF4.5-50 206706A-6 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
5/8" HJ4.5-50 206706A-6 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" AVA5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" LDF5-50A SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" AL5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" HJ5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" HJ5-75 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
7/8" HT5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-1/4" LDF6-50 SSH-114 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" AVA7-50 SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" LDF7-50A SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" AL7-50 SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" HJ7-50A SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
2-1/4" LDF12-50 206706A-6 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6)
2-1/4" HJ12-50 206706A-6 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6)
DefinitionsandAssumptions1.PerEIA-222Standard:Coefficientofdragforcoaxialcableis1.2(cylindricalmembers).Iceformscompletelyaroundmember(360degrees).Combinedwindandiceloadingisreducedby25%toreflectlowerprobabilityofwindandiceoccurringsimultaneously.2.Windspeedsaremaximum,whichincludesgustfactorsandexposurefactors.Note:Standardtowerconfigurationspacingis3to4ft.
Appendix �
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Snap-In Hanger—Recommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice
1/2" LDF4-50A SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" LDF4-75A SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HL4RP-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HJ4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HLT4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HT4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HST4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HS4RP-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-50B SSH-12 3 (0.9) 2 (0.6) 1 (0.3) 2 (0.6) 2 (0.6) 1 (0.3)
1/2" FSJ4-75A SSH-12 3 (0.9) 2 (0.6) 1 (0.3) 2 (0.6) 2 (0.6) 1 (0.3)
5/8" LDF4.5-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 1 (0.3)
5/8" HJ4.5-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 1 (0.3)
7/8" AVA5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" LDF5-50A SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" AL5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" HJ5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" HJ5-75 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
7/8" HT5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-1/4" LDF6-50 SSH-114 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" AVA7-50 SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" LDF7-50A SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" AL7-50 SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
1-5/8" HJ7-50A SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
2-1/4" LDF12-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)
2-1/4" HJ12-50 206706A-6 2 (0.6) 2 (0.6) 1 (0.3) 2 (0.6) 1 (0.3) 1 (0.3)
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
DefinitionsandAssumptions1.PerEIA-222Standard:Coefficientofdragforcoaxialcableis1.2(cylindricalmembers).Iceformscompletelyaroundmember(360degrees).Combinedwindandiceloadingisreducedby25%toreflectlowerprobabilityofwindandiceoccurringsimultaneously.2.Windspeedsaremaximum,whichincludesgustfactorsandexposurefactors.Note:Standardtowerconfigurationspacingis3to4ft.
Appendix �
Hanger Spacing Guidelines
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Click-On Hanger—Recommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice
1/2" LDF4-50A L4CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1/2" LDF4-50A L4CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1/2" LDF4-50A L4CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
Note:Thesesamehangerspacingrecommendationsapplyfortheotherfollowing1/2incabletypes:LDF4-75A,HL4RP-50,HLT4-50,HS4RP-50,HST4-50,HT4-50,HJ4-50
5/8" LDF4.5-50A L45CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
5/8" LDF4.5-50A L45CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
5/8" LDF4.5-50A L45CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
Note:Thesesamehangerspacingrecommendationsapplyfortheotherfollowing5/8incabletypes:HJ4.5-50
7/8" LDF5-50A L5CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
7/8" LDF5-50A L5CLICK, 2 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
7/8" LDF5-50A L5CLICK, 3 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
Note:Thesesamehangerspacingrecommendationsapplyfortheotherfollowing7/8incabletypes:AVA5-50,VXL5-50,AL5-50,HJ5-50,HJ5-75,HT5-5
1-1/4" LDF6-50 L6CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
1-1/4" LDF6-50 L6CLICK, 2 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
1-1/4" LDF6-50 L6CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A L7CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A L7CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A L7CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
Note:Thesesamehangerspacingrecommendationsapplyfortheotherfollowing15/8incabletypes:HJ7-50A,AVA7-50,AL7-50
*ThesehangerspacingshavebeenspecifiedbasedonusingtheClick-OnHangerswithAndrewspecifiedhardwarekits.
(Note:Standardtowerconfigurationspacingis3to4ft)
DefinitionsandAssumptions1.PerEIA-222Standard:Coefficientofdragforcoaxialcableis1.2(cylindricalmembers).Iceformscompletelyaroundmember(360degrees).Combinedwindandiceloadingisreducedby25%toreflectlowerprobabilityofwindandiceoccurringsimultaneously.2.Windspeedsaremaximum,whichincludesgustfactorsandexposurefactors.
Appendix �
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Click-On Hanger—Recommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice
1/2" LDF4-50A L4CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1/2" LDF4-50A L4CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1/2" LDF4-50A L4CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
Note:Thesehangerspacingrecommendationsarealsoapplicableforthese1/2incabletypes:LDF4-75A,HL4RP-50,HLT4-50,HS4RP-50,HST4-50,HT4-50,HJ4-50
5/8" LDF4.5-50A L45CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
5/8" LDF4.5-50A L45CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
5/8" LDF4.5-50A L45CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
Note:Thesehangerspacingrecommendationsarealsoapplicableforthis5/8incabletype:HJ4.5-50
7/8" LDF5-50A L5CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
7/8" LDF5-50A L5CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
7/8" LDF5-50A L5CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
Note:Thesehangerspacingrecommendationsarealsoapplicableforthese7/8incabletypes:AVA5-50,VXL5-50,AL5-50,HJ5-50,HJ5-75,HT5-5
1-1/4" LDF6-50 L6CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1-1/4" LDF6-50 L6CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1-1/4"
1-5/8" LDF7-50A L7CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)
1-5/8" LDF7-50A L7CLICK, 2 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
1-5/8" LDF7–50A L7CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
LDF6-50 L6CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)
Note:Thesehangerspacingrecommendationsarealsoapplicableforthese15/8incabletypes:HJ7-50A,AVA7-50,AL7-50
(Note:Standardtowerconfigurationspacingis3to4ft)
Mini Click-On Hanger—Recommended Maximum Hanger Spacing
Cable Size Cable Part Number Hanger Part Number
Wind Speed 125 mph (200 km/h)
Radial Ice
6 mm–8mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 1 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
6 mm–8mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 2 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
6 mm–8mm
9 mm–12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 1 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
9 mm–12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 2 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
9 mm–12 mm
13 mm–16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 1 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
13 mm–16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 2 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)
13 mm–16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 3 Stack 2.0 (0.60) 2.0 (0.60) 2.0 (0.60)
CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 3 Stack 2.0 (0.60) 2.0 (0.60) 2.0 (0.60)
CNT-240, CNT-300, FSJ1 series 68MCLICK, 3 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
No Ice 1/2" (13 mm) 1" (25 mm)
DefinitionsandAssumptions1.PerEIA-222Standard:Coefficientofdragforcoaxialcableis1.2(cylindricalmembers).Iceformscompletelyaroundmember(360degrees).Combinedwindandiceloadingisreducedby25%toreflectlowerprobabilityofwindandiceoccurringsimultaneously.2.Windspeedsaremaximum,whichincludesgustfactorsandexposurefactors.Note:Standardtowerconfigurationspacingis3to4ft.
Appendix �
Hanger Spacing Guidelines
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
Standard Hanger for HELIAX® Elliptical Waveguide—Recommended Maximum Hanger Spacing
Waveguide Type Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
EW17 31766A-9 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80)
EW20 31766A-10 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80)
EW28 31766A-11 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 5.5 (1.68)
EW37 42396A-4 6.0 (1.80) 6.0 (1.80) 5.5 (1.68) 5.5 (1.68) 5.5 (1.68) 5.0 (1.50)
EW43 42396A-16 6.0 (1.80) 6.0 (1.80) 5.5 (1.68) 5.0 (1.50) 5.0 (1.50) 4.5 (1.37)
EW52 42396A-8 5.5 (1.68) 5.0 (1.50) 4.5 (1.37) 4.5 (1.37) 4.5 (1.37) 4.0 (1.20)
EW63 42396A-7 5.0 (1.50) 4.5 (1.37) 4.0 (1.20) 4.0 (1.20) 4.0 (1.20) 3.5 (1.07)
EW64 42396A-1 5.0 (1.50) 6.0 (1.80) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07)
EW77 42396A-11 5.0 (1.50) 6.0 (1.80) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07)
EW85 42396A-5 5.5 (1.68) 6.0 (1.80) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07)
EW90 42396A-5 5.5 (1.68) 4.5 (1.37) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.0 (0.90)
EW127A 42396A-9 5.5 (1.68) 4.5 (1.37) 3.5 (1.07) 4.5 (1.37) 4.0 (1.20) 3.0 (0.90)
EW132 42396A-9 5.5 (1.68) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)
EW180 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)
EW220 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)
EW240 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)
EW380 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)
Note:Standardtowerconfigurationspacingis3to4ft.
HELIAX® Elliptical WaveguideRecommended maximum hanger spacings are tabulated below for various wind speed and ice conditions. The recommendations are based on guidelines stated in EIA Standard RS-222 and new wind tunnel and vibration tests. They supersede those in previous Andrew catalogs.
Installations in Typical ClimatesUse the 125 mph (200 km/h), 1/2 in ice conditions, highlighted in red. Severe or Mild ClimatesUse the wind speed and ice conditions that most closely approximate the expected worst case conditions for the local climate.
Appendix �
Hanger Spacing Guidelines
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
Standard Hanger for HELIAX® Elliptical Waveguide—Recommended Maximum Hanger Spacing
Waveguide Type Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice
EW17 31766A-9 6.0 (1.80) 6.0 (1.80) 5.5 (1.68) 5.0 (1.50) 5.0 (1.50) 4.5 (1.37)
EW20 31766A-10 5.5 (1.68) 5.5 (1.68) 5.0 (1.50) 4.5 (1.37) 4.5 (1.37) 4.0 (1.20)
EW28 31766A-11 5.0 (1.50) 5.0 (1.50) 4.5 (1.37) 4.0 (1.20) 4.0 (1.20) 3.5 (1.07)
EW37 42396A-4 4.5 (1.37) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07) 3.5 (1.07) 3.0 (.090)
EW43 42396A-16 4.0 (1.20) 4.0 (1.20) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3.0 (.090)
EW52 42396A-8 3.5 (1.07) 3.5 (1.07) 3.0 (.090) 3.0 (.090) 3.0 (.090) 2.5 (0.76)
EW63 42396A-7 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.0 (0.60)
EW64 42396A-1 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)
EW77 42396A-11 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)
EW85 42396A-5 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)
EW90 42396A-5 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)
EW127A 42396A-9 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)
EW132 42396A-9 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)
EW180 43211A 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2.0 (0.60)
EW220 43211A 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2.0 (0.60)
EW240 43211A 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2.0 (0.60)
No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
DefinitionsandAssumptions1.PerEIA-222Standard:Coefficientofdragforcoaxialcableis1.2(cylindricalmembers).Iceformscompletelyaroundmember(360degrees).Combinedwindandiceloadingisreducedby25%toreflectlowerprobabilityofwindandiceoccurringsimultaneously.2.Windspeedsaremaximum,whichincludesgustfactorsandexposurefactors.Note:Standardtowerconfigurationspacingis3to4ft.
*Thesehangerspacingrecommendationshavebeenspecifiedusingtheclick-onhangerswithAndrewspecifiedhardwarekits.
IND
EX
114468............................... 28114469............................... 2812395-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111316MCLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . 1319256B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8204673-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-24. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-2A. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-13. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-14. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-15. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-16. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-17. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-18. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-19. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204989. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32204989-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33204989-28. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33204989-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33206706A-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9206706A-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9207270............................... 32207270............................... 32209874............................... 25209874............................... 25220497............................... 33220498............................... 33221213............................... 21221213............................... 21221213-S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21223158-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33223158-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33223158-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33223700-724. . . . . . . . . . . . . . . . . . . . . . . . . . . 33224352............................... 28224354............................... 28224355............................... 28224356............................... 28224360............................... 28224361............................... 27224361............................... 27224361............................... 27224362............................... 27
224362............................... 27224362............................... 27224363............................... 28224368............................... 28224373............................... 28224380............................... 28224395............................... 28241088............................... 32241088-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-60. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-64. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241475-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20241545............................... 33241953............................... 27243095-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1324312A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8243684............................... 12243684............................... 16243684-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16243684-MH . . . . . . . . . . . . . . . . . . . . . . . . . . . 15243950............................... 38243951............................... 38244350............................... 12244373............................... 26244374............................... 26244374............................... 26244374............................... 28244375............................... 26244375............................... 28244376............................... 26244377............................... 26244377............................... 28244378............................... 26244378............................... 27244379............................... 26244379............................... 28244394............................... 27244459-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27244459-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28244459-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28244494............................... 27244494............................... 27
244495............................... 32244847............................... 38245154............................... 26245154............................... 27245171............................... 20245172............................... 20245173............................... 20245174.............................. 20245175............................... 20245314-127A. . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-132. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-180. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-220. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-240. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-37. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-43. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-52. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-63. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-64. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-77. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-85. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-90. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245516............................... 27245529-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 32247696............................... 26247696............................... 26247696............................... 27247698............................... 26247698............................... 28247763............................... 16247763-I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16252026-10KT. . . . . . . . . . . . . . . . . . . . . . . . . . 13252027-10KT. . . . . . . . . . . . . . . . . . . . . . . . . . 13252028-10KT. . . . . . . . . . . . . . . . . . . . . . . . . . 13252029-10KT. . . . . . . . . . . . . . . . . . . . . . . . . . 1326985A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 829958................................. 829961................................. 830848-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1731031-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 831535................................. 831670-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631766A-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531768A-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631769-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531769-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531771................................ 1531771-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531771-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Index
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��
31771-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531771-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1534759................................. 835849A-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2335849A-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2335849A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233CCGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 840417................................ 1742334................................ 1742396A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542615-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2143094................................. 843211A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1548939A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2268MCLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13912MCLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 139905-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219905-71. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21A5MCPT-78 . . . . . . . . . . . . . . . . . . . . . . . . . . . 25A5MCPT-BK5 . . . . . . . . . . . . . . . . . . . . . . . . . . 25ABT-DFDM-ADBH . . . . . . . . . . . . . . . . . . . . . . . 38ABT-DFDM-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 38ABT-DMDF-ADBH . . . . . . . . . . . . . . . . . . . . . . . 38ABT-DMDF-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 38ABT-NFNM-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 38ABT-NMNF-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 38ADCB-DFDM-DB. . . . . . . . . . . . . . . . . . . . . . . . 38APB-BNFNF-2400. . . . . . . . . . . . . . . . . . . . . . . 37APC-BDFDM-450 . . . . . . . . . . . . . . . . . . . . . . . 37APC-BDFDM-700 . . . . . . . . . . . . . . . . . . . . . . . 37APC-BDFDM-DB . . . . . . . . . . . . . . . . . . . . . . . . 37
APG-BDFDF-090. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BDFDF-350. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BDFDM-090 . . . . . . . . . . . . . . . . . . . . . . . 37APG-BDFDM-350 . . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNF-090. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNF-350. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNM-090 . . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNM-350 . . . . . . . . . . . . . . . . . . . . . . . 37APORT-13-4. . . . . . . . . . . . . . . . . . . . . . . . . . . 22APTA5DC-BDF-DB. . . . . . . . . . . . . . . . . . . . . . . 38APTA7DC-BDF-DB. . . . . . . . . . . . . . . . . . . . . . . 38APT-BDFDF-DB. . . . . . . . . . . . . . . . . . . . . . . . . 37APT-BDFDM-DB. . . . . . . . . . . . . . . . . . . . . . . . . 37APT-BNFNF-DB. . . . . . . . . . . . . . . . . . . . . . . . . 37APT-BNFNM-DB. . . . . . . . . . . . . . . . . . . . . . . . . 37APTDC-BDFDF-DB. . . . . . . . . . . . . . . . . . . . . . . 37APTDC-BDFDM-DB. . . . . . . . . . . . . . . . . . . . . . 37APTDC-BNFNM-DB. . . . . . . . . . . . . . . . . . . . . . 37APT-DFDF-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 37APT-DFDM-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 37APT-NFNF-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 37APT-NFNM-DB. . . . . . . . . . . . . . . . . . . . . . . . . . 37ARA-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11AWE-11412 . . . . . . . . . . . . . . . . . . . . . . . . . . . 19AWE-15812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 19AWE-7812 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19AWE-A12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19C2SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8C2SGRIP-2IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8CAP-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22CGT114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT158 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT214 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CM-TB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TBR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CPT-158U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-158U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-158U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPT-78U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-78U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-78U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27CPT-BK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BK5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BK6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BK7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-E2L2DIN........................... 24CPT-E2L2DIN........................... 24CPT-E2L2DIN........................... 24CPT-E2L2N. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-E2L2N. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
CPT-E2L2N. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-F4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-F4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-F4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27CPT-L1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L45RC. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L45RC. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L4ARC1. . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L4ARC1. . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L4ARC1. . . . . . . . . . . . . . . . . . . . . . . . . . . 27CPTL6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTL6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTL6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-114. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTV2-114. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-158. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTV2-158. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-BK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTV2-BK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-BK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CS-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11CSGL4-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-10S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-15S4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-10S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-15S4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-10S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-15S4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-10S2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-15S4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33DF-CAPKIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38E2SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8E2SGRIP-2IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8EP-CAP5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22EWSH-127A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-132 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-240 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-52 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-77 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9F1SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F1SGRIP-1IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Index
��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com
F2SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F2SGRIP-2IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F4SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F4SGRIP-4IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8GASTUBE-090. . . . . . . . . . . . . . . . . . . . . . . . . . 38GBKIT-0414 . . . . . . . . . . . . . . . . . . . . . . . . . . . 35GK-SUNV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33GKT-114A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-114A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-114A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-158A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-158A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-158A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-78A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-78A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-78A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27GKT-BK512. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK512. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK512. . . . . . . . . . . . . . . . . . . . . . . . . . . . 27GKT-BK512. . . . . . . . . . . . . . . . . . . . . . . . . . . . 27GKT-BK67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-BK67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-BKF4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-F4A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-F4A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-L4A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-L4A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-L4A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27L12SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L12SGRIP-12IK. . . . . . . . . . . . . . . . . . . . . . . . . . 8L12SGRIP-12IK. . . . . . . . . . . . . . . . . . . . . . . . . . 8L1SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L1SGRIP-1IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L2SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L2SGRIP-2IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L45CLAMP-(). . . . . . . . . . . . . . . . . . . . . . . . . . 14L45CLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L45SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L45SGRIP-45IK. . . . . . . . . . . . . . . . . . . . . . . . . . 8L45SGRIP-45IK. . . . . . . . . . . . . . . . . . . . . . . . . . 8L4CLAMP-(). . . . . . . . . . . . . . . . . . . . . . . . . . . 14L4CLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L4SCLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L4SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L4SGRIP-4IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L4SGRIP-4IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L5CLAMP-(). . . . . . . . . . . . . . . . . . . . . . . . . . . 14L5CLICKB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L5SCLICKB. . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L5SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L5SGRIP-5IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L5SGRIP-5IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L6CLAMP-(). . . . . . . . . . . . . . . . . . . . . . . . . . . 14L6CLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L6SCLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L6SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L6SGRIP-6IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L6SGRIP-6IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L7CLAMP-(). . . . . . . . . . . . . . . . . . . . . . . . . . . 14L7CLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
L7SCLICK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L7SGRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L7SGRIP-7IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L7SGRIP-7IK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8MCPT-1412............................ 25MCPT-1412............................ 27MCPT-1412............................ 27MCPT-3812............................ 25MCPT-3812............................ 27MCPT-78.............................. 25MCPT-78.............................. 27MCPT-BK4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MCPT-BK5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MCPT-L4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MCPT-L4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27MCPT-V2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MF39901-10........................... 17MT-F1598. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11MT-F1599. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11MT-F1600. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11PLUG-114. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22PLUG-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22PLUG-158. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22PLUG-78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22R8CLAMP-(). . . . . . . . . . . . . . . . . . . . . . . . . . . 14RM-USBG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11SA-38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12SCE-114. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-158. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SG-IT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8SGL12-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL12-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL12-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL45-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL45-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL45-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-06B2-T. . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-15B4-T. . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-06B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-06B2-T. . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-06S2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-10B2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-15B4. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-15B4-T. . . . . . . . . . . . . . . . . . . . . . . . . . 33SHT-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10SSH-114. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SSH-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSH-158. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSH-78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSHA-38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSHAK-3812. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SS-TB2550. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11SS-TB6080. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11STS3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10STS3-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10STS3-34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10STS3-45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10TB-COMP-KIT. . . . . . . . . . . . . . . . . . . . . . . . . . 27UA-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10UAAI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10UG12158-15B4. . . . . . . . . . . . . . . . . . . . . . . . . 33UGBA-34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBA-36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBA-DIN-34 . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBA-DIN-36 . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0210 . . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0210-T. . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0212 . . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0212-T. . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0214 . . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0214-T. . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0412 . . . . . . . . . . . . . . . . . . . . . . . . . . 35UGBKIT-0412-T. . . . . . . . . . . . . . . . . . . . . . . . . 35UGBKIT-0414-T. . . . . . . . . . . . . . . . . . . . . . . . . 35UGBKIT-0420 . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-0420-T. . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-0424 . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-0424-T. . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-2T............................. 34UGBKIT-T.............................. 35WGB4-127. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-132. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-180. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-220. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-240. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-77. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-85. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-122. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-132. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-180. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-220. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-240. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-77. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-85. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Index
Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0
Andrew Corporation3 Westbrook Corporate CenterSuite 900Westchester, IL 60154
Customer Support CenterFrom North AmericaTelephone: 1-800-255-1479Fax: 1-800-349-5444
InternationalTelephone: +1-708-873-2307Fax: +1-708-349-5444Internet: www.andrew.com
All designs, specifications, and availabilities of products and services presented in this catalog are subject to change without notice.
Bulletin CA-101772-EN (06/07) Printed in the USA© 2007 Andrew Corporation, Westchester, IL 60154 USA