PART B: Fan speed controller operation
Example: An efficient way to control the fan units is to chain connect each Silent Fan Units.Then attach this set to one of the Speed Controllers.
Note:If 4 or more Silent Fan Units are chain connected altogether, please attach the set to either Speed Controller #2 or #3. This is because each Silent Fan Unit requires 0.10Amp: [0.1Amp X 4 Silent Fan Units] is greater than 0.35Amp, so it must be connected to Fan2 or Fan3 only.
Installation GuideInstallation GuideHardcano 10Hardcano 10
USB2.0 connection: it is compatible for USB1.1Please consult your motherboard manual to find out the position of USB2.0 connection on your motherboard. You can see 9-pins from HardcanoUSB2.0.Find out the following each pin to connect onto your M/B.
-VCC1 connects to VCC1or USB+5V or USB Power on your M/B.
-DATA-1 connects to USB1- or LDM1 or USB2- on your M/B.
-DATA+1 connects to USB1+ or LDP1 or USB2+ on your M/B
-GND1 connects to GND1 or GND.
-SHIELD connects to NG on your M/B.
-VCC2 connects to VCC2 or USB+5V or USB Power on your M/B.
-DATA-2 connects to USB2- or LDM2 or USB3- on your M/B.
-DATA+2 connects to USB2+ or LDP2 or USB3+ on your M/B
-GND2 connects to GND1 or GND.
IEEE 1394 firewire connection - Identify and find out IEEE1394 port in the I/O shield (backside of the
case ), connect the IEEE1394 to it.
- If you can not find IEEE1394 port from I/O shield but exist 1394 function
on the motherboard, please install PCI bracket with IEEE1394(usually
enclosed in the M/B package), then connect it.
Note:One or two pins may be shown in both rows as NC on some motherboards, please ignore it, NC means empty pin
PART C: USB 2.0 & IEEE 1394 firewire
If the fan unit you wish to control is over 0.35Amp, please connect it to Speed Controller # 1. However, the total current of fan unit is less than 0.35Amp, please connect it to Fan2.
If you wish to control a fan unit with a 3-pin power connection, please use the included CPU Fan Adaptor.Once connected, you may still monitor the RPM by connecting the Yellow wire directly to motherboard.
FAN1 Controller
FAN2 Controller
ww
w.th
erm
alta
ke.c
om
the
rma
ltake
@th
erm
alta
ke.c
om
ww
w.th
erm
alta
ke.c
om
the
rma
ltake
@th
erm
alta
ke.c
om
ww
w.th
erm
alta
ke.c
om
the
rma
ltake
@th
erm
alta
ke.c
om
PART A: LCD display with Temp. Alarm
- Please refer to the other page(Hardcano 9 Installation Guide)
ww
w.th
erm
alta
ke.c
om
the
rma
ltake
@th
erm
alta
ke.c
om
ww
w.th
erm
alta
ke.c
om
the
rma
ltake
@th
erm
alta
ke.c
om
ww
w.th
erm
alta
ke.c
om
the
rma
ltake
@th
erm
alta
ke.c
om
PART A: LCD display with Temp. Alarm
ON / OFF
O oC/ FRESET
RECORD
Alarm Temp. Setting
fig 1
There are two temperature shown on the screen (T1, T2). T1 always mean pre-setting temperature as well as T2 representatives the temperature from sensor.
ON / OFF: power on or power off switch.O oC/ F : Celsius and Fahrenheit display switch.
RESET: clean the temperature setting. (MAX & MIN)
REC: please adjust the pre-setting temperature by using the cross-head screw driver. Whatever it shows the temperature you would like to set, ( the screen should be shown without MIN or MAX, see fig 1), please press the button "REC" to record the temperature.Alarm Temp. Setting: Control the temperature you would like to set (Please use the cross-head screw driver to adjust the temperature).
Specificationo o o o-Range: 0 C ~ 90 C (32 F ~ 194 F)
o o-Resolution: 0.1 C (0.1 F)o o-Accuracy: +/-1 C (+/-2 F)
-Sampling rate: 3 seco o-Alarm setting range: 40 C ~ 90 C
-Power: Lithium battery CR2032 3V
Note:When the screen is shown MAX, it means the highest temperature you have recorded. In the meanwhile, T1 is the highest temperature you set, T2 is the highest temperature that the sensor detected.
Note:When the screen is shown MIN, it means the lowest temperature you have recorded. In the meanwhile, T1 is the lowest temperature you set, T2 is the lowest temperature that the sensor detected.
Monitor Switch
Press "REC" Button
Press "REC" Button
Normal Status
"MAX" Status
"MIN" Status
PART B: Fan speed controller operation
Example: An efficient way to control the fan units is to chain connect each Silent Fan Units.Then attach this set to one of the Speed Controllers.
Note:If 4 or more Silent Fan Units are chain connected altogether, please attach the set to either Speed Controller #2 or #3. This is because each Silent Fan Unit requires 0.10Amp: [0.1Amp X 4 Silent Fan Units] is greater than 0.35Amp, so it must be connected to Fan2 or Fan3 only.
Installation GuideInstallation GuideHardcano 9Hardcano 9
If the fan unit you wish to control is over 0.35Amp, please
connect it to either Speed Controller # 2 or 3. However, the total
current of fan unit is less than 0.35Amp, please connect it to Fan1
or Fan 4.
If you wish to control a fan unit with a 3pin power connection,
please use the included CPU Fan Adaptor.Once connected, you
may still monitor the RPM by connecting the Yellow wire directly
to motherboard.
FAN1 Controller
FAN2 Controller
FAN3 Controller
FAN4 Controller