7/29/2019 60D Series QuickStart
1/12
7/29/2019 60D Series QuickStart
2/12
July 05, 2013
01-502-202499-20130705
Copyright 2013 Fortinet, Inc. All rights reserved. Fortinet, FortiGate, and FortiGuard, are registered trademarks of Fortinet, Inc., and other Fortinet
names herein may also be trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance metrics
contained herein were attained in internal lab tests under ideal conditions, and performance may vary. Network variables, different network environments
and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties,
whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinets General Counsel, with a purchaser that
to performance in the same ideal conditions as in Fortinets internal lab tests. Fortinet disclaims in full any guarantees. Fortinet reserves the right to change,
modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable.
7/29/2019 60D Series QuickStart
3/12
FortiGate/FortiWiFi 60DQuickStart Guide
Register your Fortinet product to receive:
Technical Support
New product features
Protection from new threats
Vous devez enregistrer le produit pour
recevoir:
Support technique
Nouvelles fonctionnalites du produit
Protection contre de nouvelles menaces
La reistrazione ti permette di usufruire di:
Supporto Tecnico
Nuove funzionalita
Proteezione dalle ultime minaccce
Register for Support
Debe registrar el producto para recibir:
Apoyo tcnico
Nuevas funcionalidades del producto
Proteccin contra ataques
http://support.fortinet.com/
Toll free: 1 866 648 4638
Phone: 1 408 486 7899
Fax: 1 408 235 7737
Email: [email protected]
http://support.fortinet.com/http://support.fortinet.com/7/29/2019 60D Series QuickStart
4/12
5
Box Includes
4
USB Cable Ethernet Cable
Power Cable Power Adapter
2 Wireless Antennae(Wireless models only)
Before You Begin
It is normal to not require a hostnamebut your ISP may require it.
Hostname
Write down details that you may need from your network administrator or ISP.
T1/E1, Static broadband, Cable, or DSL with a static IP
IP Address Subnet Mask
Cable Modem DHCP
Default Gateway Primary/Secondary DNS
DSL PPPoE
Username
Password
QuickStart Guide Videohttp://forti.net/vqsg
http://forti.net/vqsghttp://forti.net/vqsg7/29/2019 60D Series QuickStart
5/12
76
A
https://
Basic Connections
Connect your device to a power outlet and an Internet connection.
This is usually a modem, but could also be another device on your network.
1
WAN1
WAN2USB
DC+12V
23
4
USB
MGMT
DMZ
RESET
67
1
5
Power Connection
WAN1
Internet
LAN port 5
WAN1
WAN2USB
DC+12V
23
4
USB
MGMT
DMZ
RESET
67
1
5
FortiGate Setup Options
2
Web Browser
Setup Wizard (p.7) With FortiExplorer (pp.8-9) Fort iExplorer App
CA B OS X
Web-based Manager
1. Connect the Ethernet cable.
2. Visit 192.168.1.99 in your web browser.
3. Login using username admin and no password.
4. Click Wizard in the top right corner.
5. and save your settings.
6. Register your device from the dashboard page.
Web Browser with Ethernet cable
7/29/2019 60D Series QuickStart
6/12
8 9
B
USB MGMT
WAN1
WAN2USB
DC+12V
23
4
USB
MGMT
DMZ
RESET
67
1
5
FortiExplorer Setup Wizard
1. Follow prompts or click Register to register your device with FortiCare.
2. Click Setup Wizard.
3. Login using username admin and no password.
4. Follow Setup Wizard steps.
5. Click to complete the setup of your device.
Windows/OS X with USB
Microsoft Windows Install
2. Connect the USB cable and launch
FortiExplorer if it does not appear
automatically.
Mac OS X Install
2. Double-Click the and drag
the FortiExplorer icon to the Applications
folder.
3. Connect the USB cable.
4. Click the FortiExplorer icon to launch
the application.
1. Download FortiExplorer fromhttp://forti.net/fexp.
http://forti.net/fexphttp://forti.net/fexp7/29/2019 60D Series QuickStart
7/12
1110
USB Port
C
WAN1
WAN2USB
DC+12V
23
4
USB
MGMT
DMZ
RESET
67
1
5
iPhone/iPad/iPod Touch with Apple USB cable
FortiExplorer App
1. Download theiOS FortiExplorer App to your device from http://forti.net/fexp-ios.
2. Use your Apple USB cable to connect to the USB port.
3. Launch the FortiExplorer App and select the device model.
4. Login using username admin and no password.
http://forti.net/fexp-ios
http://forticlient.com
http://forti.net/fexp-ioshttp://forti.net/fexp-ioshttp://forticlient.com/http://forticlient.com/http://forti.net/fexp-ioshttp://forti.net/fexp-ios7/29/2019 60D Series QuickStart
8/12
1312
Device GuideFortiGate/FortiWiFi 60D Non-PoE Models Only
USB (USB A)
USB server ports
USB MGMT
(USB mini-B)
USB client port formanagement
LAN Ports 1 - 7 (RJ-45)
Gigabit Ethernet 7-port switch
connection for the internal network
WAN 1 & 2 (RJ-45)Power Connection
12V DC, 2.5A
100-240V AC,
50-60Hz adapter
WAN1WAN2USBDC+12V 234USB
MGMT DMZ
RESET
67 1
DMZ (RJ-45)
Optional connection to a DMZ network/device
or to other units for High Availability (HA)
Status
Normal
Booting up
Power
On
Off
LAN Ports Speed
Connected at 1GbpsConnected at 10/100Mbps
Not connected
WAN & DMZ Ports Link/Activity
Connected
Transmitting & receiving data
No link established
WiFi (Wireless models only)
Connected
No Connection
HA
Operating in an HA clusterDisabled
LAN Ports Link/Activity
Connected
Transmitting & receiving data
No link established
WAN & DMZ Ports Speed
Connected at 1Gbps
Connected at 10/100Mbps
Not connected
PWRSTATUSHA
WAN1WAN2DMZ
SPEED
LINK/ACT
WIFI
1 2 3 4 5 6 7
5
Internet
7/29/2019 60D Series QuickStart
9/12
1514
Device GuideFortiGate/FortiWiFi 60D PoE Models Only
USB (USB A)
USB server ports
USB MGMT(USB mini-B)
USB client port for
management
LAN Ports 1 - 7 (RJ-45)
Gigabit Ethernet 7-port switch
connection for the internal network
WAN 1 & 2 (RJ-45)Power Connection
12V DC, 5A
100-240V AC,
50-60Hz adapter
WAN1WAN2USBDC+12VUSB
MGMT DMZ
RESET
DMZ (RJ-45)Optional connection to a DMZ
network/device or to other
units for High Availability (HA)
Status
Normal
Booting up
Power
On
Off
LAN Ports Speed
Connected at 1Gbps
Connected at 10/100Mbps
Not connected
WAN & DMZ Ports Link/Activity
Connected
Transmitting & receiving data
No link established
WiFi (Wireless models only)
Active
Inactive
HA
Operating in an HA cluster
Disabled
LAN Ports Link/Activity
Connected
Transmitting & receiving data
No link established
WAN & DMZ Ports Speed
Connected at 1Gbps
Connected at 10/100Mbps
Not connected
PWR STATUS HA
WAN1WAN2DMZ
SPEED
LINK/ACT
WIFI
A B 1 2 3 4 5
A B
PoE
PoE (A & B)
PD connected
PD not connected
35 4 B2 1 A
PoE LAN Ports A & B (RJ-45)802.af, up to 15.4 W
Internet
7/29/2019 60D Series QuickStart
10/12
16
More Information
FortiGate Cookbook
Advanced installing and setup, networking, security policies
Authentication, Logging and reporting.
http://forti.net/cookbook
Training Services
Course descriptions, availability, schedules, and locations of
training programs in your area.
http://forti.net/training
CLI Reference
http://forti.net/cli
FortiOS Handbook
http://forti.net/handbook
http://forti.net/cookbookhttp://forti.net/traininghttp://forti.net/clihttp://forti.net/handbookhttp://forti.net/handbookhttp://forti.net/clihttp://forti.net/traininghttp://forti.net/cookbook7/29/2019 60D Series QuickStart
11/12
Industry Canada Equipment Standard for Digital Equipment (ICES) CanadaCAN ICES-3 (B) / NMB-3 (B)
(Wireless models only)
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
:
susceptible de provoquer un fonctionnement indsirable.
Radiation Exposure Statement(Wireless models only):
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
:
Cet quipement est conforme aux limites dexposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis
avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
Caution: The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. High-
power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/
or damage to LE-LAN devices.
Avertissement:
radars de haute puissance sont dsigns utilisateurs principaux (c.--d., quils ont la priorit) pour les bandes 5 250-5 350 MHz et 5 650-5 850 MHz et que ces radars
pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL.
(Wireless models only)
This device has been designed to operate with an antenna having a maximum gain of 2dbi, 3dbi for 2.4GHz and 1dbi, 2dbi, 4.5dbi, 6dbi for 5GHz. Antenna having a
higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by
Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated
power (e.i.r.p.) is not more than that necessary for successful communication.
:
Conformment la rglementation dIndustrie Canada, le prsent metteur radio peutfonctionner avec une antenne dun type et dun gain maximal (ou infrieur)
approuv pourlmetteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique lintention des autres utilisateurs, il faut choisir le type
dantenne et son gain de sorte que lapuissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse p as lintensit ncessaire ltablissement dune communication
satisfaisante.
European Conformity (CE) - EU
This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to your local regulations.
IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.
Rack mount instructions
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room
the manufacturer.
Reduced Air Flow -
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct
connections to the branch circuit (e.g. use of power strips).
Grounding: Ensure your Fortinet product is connected and properly grounded to a lightning and surge protector.
WAN or LAN connections that enter the premises from outside the building should be connected to an Ethernet CAT5 (10/100 Mb/s) surge protector.
Shielded Twisted Pair (STP) Ethernet cables should be used whenever possible rather than Unshielded Twisted Pair (UTP).
Electrostatic discharge (ESD) can damage Fortinet equipment. Only perform the procedures described in this document from an ESD workstation. If no such station is
Operating temperature: 0 - 40C (32 - 104F)
Storage temperature: -25 - 70C (-13 - 158F)
Humidity: 20 to 90% non-condensing
Operating Altitude:
7/29/2019 60D Series QuickStart
12/12
Fortinet.com
http://fortinet.com/http://fortinet.com/Top Related