At Mohawk/CDT, the future of connective technology isalready a reality...with copper, fiber and compositecabling systems, supporting the telecommunicationsinfrastructure for commercial, industrial and residentialarchitecture...wherever and whenever quality can’t becompromised.
Mohawk has been a leader in wire and cable innovation andquality for half a century: meeting or surpassing all standardswhile setting new ones: responding to our customers’ emerg-ing needs, and pioneering new technologies in anticipation ofthe next levels of connectivity requirements and opportunities.
Mohawk/CDT is at the leading edge of today’s rapidlychanging communications industry. Through our innovativeand expanding capabilities we are able to offer the first inde-pendently verified Category 5e 25 pair cable. And as a multi-dimensional manufacturer we offer a comprehensive fiberline from standard distribution styles to hybrid ribbon con-structions including 10 Gigabit Ethernet ready fiber.
New technologies are also now in place for our traditionalvenues; enhanced UTP and ScTP copper cables for GigabitEthernet, ATM, Fast Ethernet, FDDI, Real-Time Imaging,internet access for web-based applications and multimedia(voice/video/data) applications.
Innovative indoor network cable products are driven by thedemands of higher bandwidth performance.
• computer to internet server access for web-based applications
• Integrated multimedia applications (voice/video/data),distributed processing, imaging, medical, and CAD/CAMapplications.
• All fiber cables are manufactured with laser optimizedfiber to maximize potential bandwidth.
In engineering design, in production technology, in qualitycontrol and customer support, we’re ready to meet theneeds of the next half century.
Product and System InnovationsMohawk/CDT remains focused on cabling to meet the needsof current and Next Generation data technology. When look-ing for premier Category 6 performance enhancements,make GigaLAN your first selection. This product line exceedsall the parameters for Gigabit Ethernet and surpasses theCategory 6 standard..as well as meeting the challenges ofNext Generation technology for signal power, crosstalk,delay skew and return loss.
At the fiber frontier, our AdvanceLite™ cables since their incep-tion, have met or surpassed the emerging industry standards– including Telcordia GR-409-CORE, RUS 1753F-601 andTIA/EIA 568-B.3. UL-listed and NEC-compliant, AdvanceLite™cables are approved by several of the world’s foremosttelecommunications companies. AdvanceLite laser optimizedfiber cables are guaranteed to handle 10 Gigabit Ethernettransmissions, yet are fully compatible with existing FDDI-grade cabling.
Index
Mohawk/CDT reserves the right to revise any specifications in the interest of product enhancement.
1-800-422-9961www.mohawk-cdt.com
UTP CablesGigaLAN™ Category 6+ . . . . . . . . . . . . . . . . . . . 1GigaLink™ Category 6+ Patch Cable. . . . . . . . . 1AdvanceNet™ Category 6. . . . . . . . . . . . . . . . . . . 2AdvanceLink™ Category 6 Patch Cable . . . . . . . 2MegaLAN™ 400 Category 5e+ . . . . . . . . . . . . . . 3MegaLink™ Category 5e+ Patch Cable . . . . . . . . . 35e LAN™ Category 5e. . . . . . . . . . . . . . . . . . . . . . 45e LAN™ Category 5e Patch Cable . . . . . . . . . . . 4
ScTP CablesMegaLAN 400 Category 5e+ . . . . . . . . . . . . . . 5MegaLink Category 5e+ Patch Cable . . . . . . . . . 55e LAN Category 5e . . . . . . . . . . . . . . . . . . . . . 65e LAN Category 5e Patch Cable . . . . . . . . . . . 6
High Pair CountUTP & ScTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Fiber Optic CablesAdvanceLite™ and Optical Characteristics . . . . 8Distribution Cables . . . . . . . . . . . . . . . . . . . . . . 9Breakout Cables . . . . . . . . . . . . . . . . . . . . . . . 10Loose Tube Cables . . . . . . . . . . . . . . . . . . . . . 11RiserLite™ Loose Tube Cables . . . . . . . . . . . . 12Simplex and Duplex Cables . . . . . . . . . . . . . . 13Field Breakout Kit . . . . . . . . . . . . . . . . . . . . . . 13
Jacket Colors for Patch Cables
1
GigaLAN is the highest performance unshielded twisted pair(UTP) cable available today. The “FlexWeb” construction iso-lates the pairs throughout the length of the cable, while provid-ing an installer-friendly cable.
The unique GigaLAN “flex-web” construction isolates thecable pairs and enhances the pair-to-pair balance for supe-rior crosstalk, LCL and LCTL performance. Compact cabledesign meets the diameter requirements specified inTIA/EIA-568-B, providing flexibility and ease of installation.Electrical performance is ETL verified to TIA/EIA 568-B.2-1Category 6.
• Tested to 550 MHz – with verified stability
• Lifetime Warranty *
• 34% increase in power due to lower insertion loss char-acteristics at 100 MHz and greater than 50% at 250 MHzthan Category 6.
• 7 dB Minimum – Improvement in Near End Crosstalkvs. Category 6 NEXT
• 33 dB Minimum ACR @ 100 MHz and positive ACR to 460 MHz.
• Application – Proven support for Gigabit Ethernet /1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, 100Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHzBroadband Video and standards under development suchas ATM at 622 Mbps, 1.2, 2.4 and 4.8 Gbps.
• 100% Teflon® insulation (plenum)
• Enhanced Performance Parameters – All electricalcharacteristics proven to exceed TIA/EIA 568-B.2-1 andISO/IEC 11801 Category 6 requirements: including NEXTand ELFEXT (Pair-to-Pair and Power Sum), Insertion Loss,Return Loss, and Delay Skew.
• This cable and/or its manufacture are covered by USPatent Nos. 6,074,503 and 5,424,491.
* Warranty available with MAC and SystemMATETM programs.
M57418 4 PAIR Thermoplastic White PVC 34 51 UL, c(UL)Non-Plenum 24 AWG .244 6.20 CMR, MPR
UTP
M57413 4 PAIR FEP Teflon** White ThermoPlen®* 35 52 UL, c(UL)Plenum 24 AWG .229 5.82 CMP, MPP
UTP .
M58374 4 Pair FEP Teflon** Clear FEP Teflon** 35 52 UL CMPPlenum Plus 24 AWG .219 5.56 Limited Combustible
UTP c(UL) CMP
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
*Plenum rated Thermoplastic **Teflon is a registered trademark of DuPont.
Jacket Colors for 4-Pair Non-Plenum
GigaLink™ Patch Cables
M57634 4 PAIR Thermoplastic White PVC 29 43 UL, CM24 AWG (7/32) TC .226 5.7 CSA, CMG
UTP
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
Jacket Color Mohawk # Jacket Color Mohawk #
Category 6+ Patch CableTested to 550 MHz
WHITE M57634 VIOLET M57639
BLUE M57635 ORANGE M57640
DEC 068 GRAY M57636 RED M57641
YELLOW M57637 BLACK M57642
GREEN M57638 PINK M58205
Jacket Color Mohawk # Jacket Color Mohawk #WHITE M57418 RED M57621
BLUE M57419 PINK M57867
YELLOW M57420 VIOLET M57870
GREEN M57421 ORANGE M57868
DEC 068 GRAY M57422 BLACK M57869
Jacket Color Mohawk # Jacket Color Mohawk #WHITE M57413 RED M57620
BLUE M57414 PINK M57750
YELLOW M57415 VIOLET M57860
LIME GREEN M57416 ORANGE M57861
GRAY M57417 BLACK M57866
GigaLAN™
Category 6+ CableTested to 550 MHz
Verified by ETL to TIA/EIA-568-B.2-1
Safety listed to NEC (NFPA 70)
Jacket Colors for 4-Pair Plenum
WHITE M56905 LIME GREEN M57197
BLUE M57193 RED M57198
PINK M57194 ORANGE M57199
YELLOW M57195 BLACK M57200
GRAY M57196 VIOLET M57201
2
AdvanceNet is unshielded twisted pair cable tested to 550MHz and ETL verified to TIA/EIA 568-B.2-1 Category 6.
With “FlexWeb” construction, the AdvanceNet cable isolatesthe pairs throughout the length of the cable, while providing around installer-friendly cable.
• 25 Year Warranty *
• 28 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM upto 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T /IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1,xDSL, ISDN, 550 MHz Broadband Video and standardsunder developement such as ATM at 622 Mbps, 1.2 and 2.4 Gbps.
• 13 dB Minimum – Improvement in Near End Crosstalk vs. Category 5e NEXT
• .25 ns/meter Maximum Skew – Tightly controlled propagation delay
• 100% Teflon® insulation (plenum)
• Enhanced Performance Parameters – All electrical characteristics proven to exceed TIA/EIA 568-B.2-1 andISO/IEC 11801 Category 6 requirements: NEXT and ELFEXT (Pair-To-Pair and Power Sum), Insertion Loss, Return Loss, and Delay Skew.
• This cable and/or its manufacture are covered by USPatent Nos. 6,074,503 and 5,424,491.
* Warranty available with MAC and SystemMATETM programs.
WHITE M56889 GREEN M57206
BLUE M57202 RED M57207
PINK M57203 ORANGE M57208
YELLOW M57204 BLACK M57209
DEC 068 GRAY M57205 VIOLET M57210
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
*Plenum rated Thermoplastic **Teflon is a registered trademark of DuPont.
Jacket Colors for 4 Pair Non-PlenumJacket Color Mohawk # Jacket Color Mohawk #
Jacket Colors for 4 Pair PlenumJacket Color Mohawk # Jacket Color Mohawk #
AdvanceLink™ Patch CablesCategory 6 Patch CableTested to 550 MHz
M56889 4 PAIR Thermoplastic White PVC 30 45 UL, c(UL)Non-Plenum 24 AWG .227 5.77 CMR, MPR
UTP
M56905 4 PAIR FEP Teflon** White ThermoPlen®* 31 46 UL, c(UL)Plenum 24 AWG .209 5.31 CMP, MPP
UTP
. M58375 4 PAIR FEP Teflon** Clear FEP Teflon** 31 46 UL CMPPlenum PlusTM 24 AWG .199 5.1 Limited Combustible
UTP c(UL) CMP
WHITE M57507 VIOLET M57517
BLUE M57508 ORANGE M57518
DEC 068 GRAY M57509 RED M57519
YELLOW M57511 BLACK M57520
GREEN M57512 PINK M58204
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
Jacket Color Mohawk # Jacket Color Mohawk #
M57507 4 PAIR Thermoplastic White PVC 25 37 UL, CM24 AWG (7/32) TC .210 5.33 CSA, CMG
UTP
Jacket Colors for Patch Cables
Category 6 CableTested to 550 MHz
AdvanceNet™
Verified by ETL to TIA/EIA-568-B.2-1
Safety listed to NEC (NFPA 70)
M55989 4 PAIR Thermoplastic White PVC 23 34 UL, c(UL)Non-Plenum 24 AWG .201 5.11 CMR, MPR
UTP
M55988 4 PAIR Dual Insulation*** White ThermoPlen®* 24 36 UL, c(UL)Plenum 24 AWG FEP on all 4 pairs .186 4.72 CMP, MPP
UTP
M58379 4 PAIR FEP Teflon** Clear FEP Teflon** 24 36 UL, CMPPlenumPlus™ 24 AWG .171 4.34 Limited Combustible
UTP c(UL) CMP
Jacket Colors for 4 Pair Plenum
3
MegaLAN 400 is ETL Verified to Category 5e.
• 20 Year Warranty *
• 20 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T /IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10 BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622Mbps and 1.2 Gbps.
• 5 dB Minimum – Improvement in Near End Crosstalk vs.standard Category 5e NEXT.
• Meets Return Loss – Category 5e Standard.
• .25 ns/meter Maximum Skew – Tightly controlled propagation delay
• Enhanced Performance Parameters – All electrical characteristics proven to exceed TIA/EIA 568-B Category 5requirements: Near End Crosstalk, Characteristic Imped-ance, Insertion Loss, and Delay Skew. Also exceeds TIA/EIA 568-B.2 Category 5e requirements: Power SumNEXT, and Far End Crosstalk – ELFEXT and PS-ELFEXT.
• Engineered for Future Applications – More than 9 yearsof service and still going strong, MegaLAN 400 has a proventrack record of successful installations.
• User Friendly – No special stripping tools. No waiting for deliveries. No compromises. Proven Performance all the way.
• This cable and/or its manufacture are covered by US PatentNo. 5,424,491.
* Warranty available with MAC and SystemMATETM programs.
MegaLink™ Patch Cables
WHITE M55988 RED M56072
BLUE M56168 ORANGE M56876
PINK M56092 BLACK M56877
YELLOW M56093 VIOLET M56878
GRAY M56882 DEC 068 GRAY M57286
LIME GREEN M56166 BROWN M58320
WHITE M55989 VIOLET M57048
BLUE M56167 ORANGE M56954
PINK M56094 RED M56670
YELLOW M56095 BLACK M57129
GREEN M56165 DEC 068 GRAY M56746
DK. VIOLET M57822 BROWN M58365
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
*Plenum rated Thermoplastic **Teflon is a registered trademark of DuPont. ***US Patent No. 5,563,377Jacket Colors for 4 Pair Non-Plenum
Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color Mohawk #
DEC 068 GRAY M57071
BLUE M57076
WHITE M56726
YELLOW M56985
GREEN M57075
VIOLET M57077
ORANGE M57074
RED M57073
BLACK M57216
DARK GRAY M57569
PINK M57570
BROWN M57823
M56726 4 PAIR Thermoplastic White PVC 25 37 UL, CM24 AWG (7/32) TC .200 5.08 CSA, CMG
UTP
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
Jacket Color Mohawk # Jacket Color Mohawk #
Category 5E+ Patch Cable
Jacket Colors for Patch Cables
MegaLAN™400Category 5E+ CableTested to 400 MHz
Verified by ETL to TIA/EIA-568-B.2
Safety listed to NEC (NFPA 70)
M57552 4 PAIR Thermoplastic DEC 068 Gray PVC 22 33 UL, c(UL)Non-Plenum 24 AWG .194 4.93 CMR, MPR
UTP
M57545 4 PAIR Dual Insulation*** Gray ThermoPlen®* 23 34 UL, c(UL)Plenum 24 AWG FEP on all 4 pairs .180 4.57 CMP, MPP
UTP
M58104 4 PAIR FEP Teflon** Clear FEP Teflon** 23 34 UL, CMPPlenumPlus™ 24 AWG .170 4.32 Limited Combustible
UTP c(UL) CMP
DEC 068 GRAY M57552 GREEN M57557
BLUE M57553 VIOLET M58007
WHITE M57554 RED M58008
PINK M57555 ORANGE M58009
YELLOW M57556 BLACK M58010
LIME GREEN M58234 DK. BROWN M58312
4
• 15 Year Warranty *
• 14 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM upto 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T /IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1,xDSL, ISDN, 550 MHz Broadband Video and standardsunder development such as ATM at 622 Mbps.
• 4 dB Minimum – Improvement in Near End Crosstalk vs. TIA/EIA 568-B Category 5
• ETL Verified to Category 5e
• .25 ns/meter Maximum Skew – Tightly controlled propagation delay
• Engineered for Future Applications – Tested for allparameters specified...for 4 pr UTP in TIA/EIA 568-B.2,including PS-NEXT, Return Loss, ELFEXT and PS-ELFEXT.
• This cable and/or its manufacture are covered by USPatent No. 5,424,491.
* Warranty available with MAC and SystemMATETM programs.
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
*Plenum rated Thermoplastic **Teflon is a registered trademark of DuPont. ***US Patent No. 5,563,377
5e LAN Patch Cables
M58126 4 PAIR Thermoplastic White PVC 25 37 UL, CM24 AWG (7/32) TC .200 5.08 CSA, CMG
UTP
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
Category 5e Patch Cable
Jacket Colors for 4 Pair Plenum
GRAY M57545 BROWN M57723
BLUE M57546 VIOLET M57761
WHITE M57547 RED M57887
PINK M57548 ORANGE M57924
YELLOW M57550 BLACK M57936
LIME GREEN M57551 KELLY GREEN M58069
Jacket Colors for 4 Pair Non-PlenumJacket Color Mohawk # Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color Mohawk #
WHITE M58126
BLUE M58127
PINK M58135
YELLOW M58129
DEC 068 GRAY M58128
GREEN M58130
RED M58133
ORANGE M58132
BLACK M58134
VIOLET M58131
Jacket Color Mohawk # Jacket Color Mohawk #Jacket Colors for Patch Cables
5e LAN™
Category 5e CableTested to 200 MHz
Verified by ETL to TIA/EIA-568-B.2
Safety listed to NEC (NFPA 70)
WHITE M57542 GREEN M58219
DEC 068 GRAY M57543 RED M57770
BLUE M57544 ORANGE M58220
PINK M58226 BLACK M58221
YELLOW M58218 VIOLET M58222
DK. GRAY M58223 BROWN M58224
5
M55987 4 PAIR Thermoplastic White PVC 33 49 UL, c(UL)Non-Plenum 24 AWG .254 6.45 CMR, MPR
ScTP
M55986 4 PAIR FEP Teflon** White ThermoPlen®* 35 52 UL, c(UL)Plenum 24 AWG .233 5.92 CMP, MPP
ScTP .
Category 5E+ cable in a screened twisted pair (ScTP or FTP) design, consisting of an overall tape/drain shield.
MegaLAN 400 ScTP is ETL Verified to Category 5e.
•20 Year Warranty *
•20 dB Minimum ACR @ 100 MHz – Proven support for Giga-bit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3,ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3,4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550MHz Broadband Video and standards under developmentsuch as ATM at 622 Mbps and 1.2 Gbps.
• 5 dB Minimum – Improvement in Near End Crosstalk vs. standard Category 5e NEXT.
•.30 ns/meter Maximum Skew – Tightly controlled propagation delay.
•100% Teflon® insulation (plenum)
•Enhanced Performance Parameters – All electrical charac-teristics proven to exceed TIA/EIA 568-B Category 5 require-ments: Near End Crosstalk, Characteristic Impedance,Insertion loss and Delay Skew. Also exceeds TIA/EIA 568-B.2Category 5e requirements: Power Sum NEXT, Return Loss, andFar End Crosstalk – ELFEXT and PS-ELFEXT.
•Engineered for Future Applications – Where cabling is to beinstalled in a high external noise location. This could be in thepath of radar or next to a telecomm or a broadcast transmis-sion point. Or is security an issue? When quality cable is prop-erly installed, grounded, and tested, shielded cable providesmeasurably lower RF emissions.
•Use All Shielded Components for a Shielded or Screened System – Mohawk/CDT strongly recommends the use of shielded or screened connecting hardware, and all shielded or screened cords: patch, work area and equipment cords should be used throughout the structured cabling system.
•This cable and/or its manufacture are covered by USPatent No. 5,424,491.* Warranty available with MAC and SystemMATETM programs.
WHITE M55986 RED M57364
BLUE M57360 ORANGE M57365
PINK M57322 BLACK M57366
YELLOW M57361 VIOLET M57367
GRAY M57362 DEC 068 GRAY M57368
LIME GREEN M57363
WHITE M55987 GREEN M57374
BLUE M57370 RED M57375
PINK M57371 ORANGE M57376
YELLOW M57372 BLACK M57377
DEC 068 GRAY M57373 VIOLET M57378
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
*Plenum rated Thermoplastic **Teflon is a registered trademark of DuPont.
Jacket Colors for PlenumJacket Color Mohawk # Jacket Color Mohawk #
Jacket Colors for Non-PlenumJacket Color Mohawk # Jacket Color Mohawk #
M57542 4 PAIR Thermoplastic White PVC 25 37 UL, CMG26 AWG (7/34) TC .211 5.36 c(UL), CMG
ScTP
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
Jacket Color Mohawk #
MegaLink™ ScTP Patch CablesCategory 5E+ Screened Patch CableTested to 400 MHz
Jacket Color Mohawk #Jacket Colors for Patch Cables
MegaLAN™400 ScTPCategory 5E+ Screened CableTested to 400 MHz
Verified by ETL to TIA/EIA-568-B.2
Safety listed to NEC (NFPA 70)
WHITE M58208 GREEN M58213
BLUE M58209 RED M58214
PINK M58210 ORANGE M58215
YELLOW M58211 BLACK M58216
DEC 068 GRAY M58212 VIOLET M58217
WHITE M58185 RED M58190
BLUE M58186 ORANGE M58191
PINK M58187 BLACK M58192
YELLOW M58188 VIOLET M58193
GRAY M58144 DEC 068 GRAY M58194
LIME GREEN M58189
WHITE M58195 GREEN M58199
BLUE M58196 RED M58200
PINK M58197 ORANGE M58201
YELLOW M58198 BLACK M58202
DEC 068 GRAY M58145 VIOLET M58203
6
M58208 4 PAIR Thermoplastic White PVC 25 37 UL, CMG26 AWG (7/34) TC 211 5.36 c(UL), CMG
ScTP
M58145 4 PAIR Thermoplastic DEC 068 Gray PVC 32 48 UL, c(UL)Non-Plenum 24 AWG .240 6.10 CMR, MPR
ScTP
M58144 4 PAIR FEP Teflon** Gray ThermoPlen®* 34 51 UL, c(UL)Plenum 24 AWG .230 5.84 CMR, MPP
ScTP
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
*Plenum rated Thermoplastic **Teflon is a registered trademark of DuPont.
Jacket Colors for 4 Pair Non-PlenumJacket Color Mohawk # Jacket Color Mohawk #
Jacket Colors for 4 Pair PlenumJacket Color Mohawk # Jacket Color Mohawk #
5e LAN™ ScTP Patch Cables
Jacket Type WeightMohawk Cable Dielectric Diameter lbs/ kg/ ListingsPart No. Type Type inch mm M' km
Jacket Colors for 4 Pair ScTP Patch CablesJacket Color Mohawk # Jacket Color Mohawk #
Category 5e Screened Patch Cable
• 15 Year Warranty*
• 14 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM upto 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T /IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1,xDSL, ISDN, 550 MHz Broadband Video and standardsunder development such as ATM at 622 Mbps.
• 4 dB Minimum – Improvement in Near End Crosstalk vs. TIA/EIA 568-B Category 5
• ETL Verified to Category 5e
• .30 ns/meter Maximum Skew – Tightly controlled propagation delay
• 100% Teflon® insulation (plenum)
• Engineered for Future Applications – Tested for allparameters specified...for 4 pr ScTP in TIA/EIA 568-B.2,including PS-NEXT, Return Loss, ELFEXT and PS-ELFEXT.
* Warranty available with MAC and SystemMATETM programs.
5e LAN™ ScTPCategory 5e Screened CableTested to 100 MHz
Verified by ETL to TIA/EIA-568-B.2
Safety listed to NEC (NFPA 70)
M56753† 25 PAIR None DEC 068 Gray PVC 119 177 4.7 119 UL, C(UL)24 AWG UTP .470 11.94 CMR, MPR
M57040† 50 PAIR None DEC 068 Gray PVC 252 375 7.5 191 UL, C(UL)24 AWG UTP .750 19.05 CMR, MPR
M56832† 25 PAIR O/A ALUM/PLY DEC 068 Gray PVC 149 222 5.25 133 UL, C(UL)24 AWG ScTP W/DW .522 13.26 CMR, MPR
7
M56801 25 PAIR None Gray ThermoPlen®* 108 161 3.6 91 UL, C(UL)24 AWG UTP .364 9.25 CMP, MPP
M56126 50 PAIR None Gray ThermoPlen®* 213 317 5.4 137 UL, C(UL)24 AWG UTP .535 13.59 CMP, MPP
M56128 100 PAIR None Gray ThermoPlen®* 424 631 7.3 185 UL, C(UL)24 AWG UTP .732 18.59 CMP, MPP
M56129 200 PAIR None Gray ThermoPlen®* 884 1315 10.4 264 UL, C(UL)24 AWG UTP 1.044 26.52 CMP, MPP
M57211 300 PAIR None Gray ThermoPlen®* 1301 1936 12.75 324 UL, C(UL)24 AWG UTP 1.276 32.41 CMP, MPP
M58349 400 PAIR None Gray ThermoPlen®* 1750 2604 16.0 406 UL, c(UL)24 AWG UTP 1.590 40.38 CMP, MPP
M55073 25 PAIR O/A ALUM/PLY Gray ThermoPlen®* 116 173 3.5 88 UL, C(UL)24 AWG ScTP W/DW .346 8.79 CMP, MPP
Category 3: Plenum
M55700 25 PAIR None DEC 068 Gray PVC 100 149 3.6 91 UL, C(UL)24 AWG UTP .364 9.25 CMR, MPR
M55216 50 PAIR None DEC 068 Gray PVC 197 293 5.9 150 UL, C(UL)24 AWG UTP .591 15.01 CMR, MPR
M55211 100 PAIR None DEC 068 Gray PVC 381 567 7.1 180 UL, C(UL)24 AWG UTP .707 17.96 CMR, MPR
M55212 200 PAIR None DEC 068 Gray PVC 814 1211 10.5 267 UL, C(UL)24 AWG UTP 1.054 26.77 CMR, MPR
M57098 300 PAIR None DEC 068 Gray PVC 1186 1765 12.25 311 UL, C(UL)24 AWG UTP 1.222 31.04 CMR, MPR
Category 3: Non-Plenum
M56773† 25 PAIR None Gray ThermoPlen®* 127 189 4.3 109 ETL/cETL24 AWG UTP .430 10.92 CMP, MPP
M56700 25 PAIR O/A ALUM/PLY Gray ThermoPlen®* 153 228 4.75 120 ETL/cETL24 AWG ScTP W/DW .472 11.99 CMP, MPP
Jacket Type Weight Min BendMohawk Cable Shield Type Diameter lbs/ kg/ Radius ListingsPart No. Type inch mm M' km inch mm
*Plenum rated Thermoplastic †Verified by Independent Test Laboratories **Meets TIA/EIA 568-B Backbone Cable requirements.
Category 5: Plenum
Category 5: Non-Plenum
Category 5e: Non-PlenumM58141† 25 PAIR None DEC 068 Gray PVC 119 177 4.7 119 UL, C(UL)
24 AWG UTP .470 11.94 CMR, MPR
Category 5e: PlenumM58142† 25 PAIR None Gray ThermoPlen®* 133 198 4.3 109 ETL/cETL
24 AWG UTP .430 10.92 CMP, MPP
UTP High Pair CountPower Sum Backbone Cables**OPERATING TEMP.: -20ºC to +60ºC (-4ºF to +140º F)
STORAGE TEMP.: -20ºC to +75ºC (-4ºF to +167º F)
*INSTALLATION TEMP.: 0ºC to +60ºC (32ºF to +140º F)
*THE INSTALLATION TEMPERATURE REFERS TO THE TEMPERATURE OF THE CABLE WHILE BEING INSTALLED OR PULLED. DO NOT INSTALL BELOW 0ºC (32ºF).
25 and 50 pair Category 5 and 5e cables and/or its manu-facture are covered by US Patent Nos. 5,821,466 and5,424,491.
Operating Min. OFL* Max. 1 Gigabit Ethernet 10 Gigabit EthernetGlass Code Wavelength Bandwidth Attenuation Link Length Link LengthType (X) (nm) (MHz-km) (dB/km) (meters S/L**) (meters S/L**) Grade
62.5/125 MM*** 2 850 /1300 160/500 3.25/1.0 220/550 28/300 1
Single-Mode 3 1310/1550 — 0.40/0.30 —/5000 —/10,000 --
50/125 MMAdvanceLite 600 A 850/1300 500/500 3.0/1.0 600/600 85/300 4AdvanceLite 2000 C 850/1300 1500/500 3.0/1.0 2000/600 300/300 5
62.5/125 MMAdvanceLite 300 B 850/1300 200/500 3.25/1.0 300/550 35/300 2AdvanceLite 1000 D 850/1300 200/500 3.25/1.0 500/1000 35/300 3
Operating Min. OFL* Max. 1 Gigabit Ethernet 10 Gigabit EthernetGlass Code Wavelength Bandwidth Attenuation Link Length Link LengthType (X) (nm) (MHz-km) (dB/km) (meters S/L**) (meters S/L**) Grade
62.5/125 MM*** 2 850 /1300 160/500 3.50/1.25 220/550 28/300 1
Single-Mode 3 1310/1550 — 0.80/0.50 —/5000 —/10,000 --
50/125 MMAdvanceLite 600 A 850/1300 500/500 3.50/1.25 600/600 85/300 4AdvanceLite 2000 C 850/1300 1500/500 3.50/1.25 2000/600 300/300 5
62.5/125 MMAdvanceLite 300 B 850/1300 200/500 3.50/1.25 300/550 35/300 2AdvanceLite 1000 D 850/1300 200/500 3.50/1.25 500/1000 35/300 3
8
Mohawk/CDT has been manufacturing and testing fiber opticcable in accordance with several industry standards, includ-ing Telcordia GR-409-CORE, RUS 1753F-601, and TIA/EIA-568, since 1990. The cables are listed by UnderwritersLaboratories as being in compliance with the National Elec-trical Code and are verified to the TIA/EIA-568-B.3 standardby ETL.
AdvanceLite is fiber optic cable with Gigabitperformance...ready now, for Next Generation installations.
Cables are available with fiber counts ranging from 1 to 216in multimode, single-mode, or hybrid versions. They arecompatible with all major manufacturers’ connectivity hard-ware, including LID fusion splicers.
Mohawk/CDT’s own ISO 9001 registration assures our cus-tomers of consistent quality. Also, by working closely withcustomers and industry organizations, Mohawk/CDT canprovide the best solution for a given application.
AdvanceLite features fiber optimized for laser-based protocols.Yet these cables are still compatible with LED systems. Theyprovide guaranteed link lengths to handle Gigabit Ethernet
transmission while maintaining full compatibility with existinginstalled FDDI-grade cable.
AdvanceLite cables are manufactured with Corning’s InfiniCor™optical fiber to provide the highest level of quality and consistentperformance for laser-based systems. AdvanceLite also comeswith third-party verified performance to TIA/EIA 568-B.3.
AdvanceLite 2000 provides for 300 meter cable length for10 Gigabit Ethernet backbone connection.
AdvanceLite 1000 provides for 1000 meter cable lengthusing the familiar 62.5/125 MM fiber size for Gigabit Ethernet.
AdvanceLite 600 provides for 600 meter cable length, whichexceeds ISO 11801 and IEEE 802.3/z requirements, for Gigabit Ethernet transmission.
AdvanceLite 300 provides for a 300 meter cable length forGigabit Ethernet as defined by TIA/EIA TSB-72. This architec-ture allows for collapsed backbones, if fiber is to be run to thedesk, or longer backbones for large LAN’s.
Optical Characteristics
These products have the mechanical,environmental and optical performancesverified by ETL to TIA/EIA-568-B.3.
Loose Tube
Tight Buffered & Micro-Loose Tube
* OFL - Overfilled Launch** S/L - Short wavelength (850 nm) / Long wavelength (1310 nm)
*** Discontinued - Replaced by 62.5/125 MM AdvanceLite 300
AdvanceLite™ Fiber Optic CablesMohawk/CDT’s Range of Fiber Optic Cables for Gigabit Ethernet Applications—Without the Use of Mode Conditioning Patch Cords
9
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.) *Single jacket version
Part FiberNumber Count mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X037 2 4.67 .184 24 16 7.0 2.8 4.7 1.8 801 180
M9X038 4 5.08 .200 28 19 7.6 3.0 5.1 2.0 801 180
M9X039 6 5.59 .220 34 23 8.4 3.3 5.6 2.2 1201 270
M9X040 8 5.97 .235 39 26 8.9 3.5 6.1 2.4 1201 270
M9X042 12 6.48 .255 46 31 9.6 3.8 6.6 2.6 1334 300
M9X601* 24 10.74 .423 129 87 16.0 6.3 10.9 4.3 2015 453
M9X602 24 12.60 .496 141 95 18.8 7.4 12.7 5.0 4270 960
M9X604 36 16.36 .644 249 167 24.6 9.7 16.5 6.4 6405 1440
M9X606 48 15.93 .627 238 160 23.9 9.4 16.0 6.3 4203 945
M9X609 72 19.10 .750 333 224 28.6 11.3 19.1 7.5 6005 1350
M9X619 144 24.49 .964 612 411 36.8 14.5 24.4 9.6 12,210 2745
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
Part FiberNumber Count mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X043 2 4.67 .184 24 16 7.0 2.8 4.7 1.8 801 180
M9X044 4 4.42 .174 24 16 7.0 2.8 4.7 1.8 867 195
M9X045 6 4.83 .190 27 18 7.6 3.0 5.1 2.0 1201 270
M9X046 8 5.64 .222 34 23 8.5 3.3 5.6 2.2 1201 270
M9X048 12 5.72 .225 39 26 8.6 3.4 5.8 2.3 1334 300
M9X611* 24 9.88 .389 128 86 14.7 5.8 9.9 3.9 2015 453
M9X612 24 12.52 .493 150 101 19.0 7.5 12.6 5.0 5618 1263
M9X614 36 15.34 .604 262 176 23.4 9.2 15.6 6.1 8509 1913
M9X616 48 15.32 .603 238 160 22.9 9.0 15.2 6.0 6641 1493
M9X620 72 19.91 .784 391 263 30.0 11.8 19.8 7.8 9310 2093
M9X621 144 24.21 .953 601 404 36.3 14.3 24.1 9.5 14,612 3285
Riser
Plenum
(For “X” in part number see optical characteristics on page 8.) *Single jacket version
Distribution CablesRiser UL/cUL Type OFNR / OFN FT4Plenum UL/cUL Type OFNP / OFN FT6
Recommended Applications
• Plenum or Riser cabling
• Office cabling
• Computer room cabling
Product Features
• 900 µm tight buffered fibers
• Color coded for easy termination
• Flame Retardant
• UL listed for code compliance
FIBER BUNDLE DETAIL
ARAMID STRENGTHELEMENTS
COLOR CODEDJACKET
SPECIFIED FIBER(COLOR CODED)
UNJACKETEDCENTRALSTRENGTHELEMENT
BUNDLES OF UP TO12 FIBERS EACH
2-12 Fibers >12-144 Fibers
OUTER JACKET OVERAL POLYESTERTAPE BARRIER
ARAMIDSTRENGTHELEMENTS
COLOR CODEDTHERMO-PLASTICJACKET
900 MICRONTIGHT BUFFEREDFIBER CENTRAL
MEMBER2.0 mmSUB-UNITS
SUB-UNIT DETAIL
OUTER JACKET
Part FiberNumber Count mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X013 2 5.84 .230 31 21 8.9 3.5 5.8 2.3 801 180
M9X014 4 6.68 .263 45 30 9.9 3.9 6.6 2.6 1535 345
M9X015 6 7.11 .280 61 41 10.7 4.2 7.1 2.8 2415 543
M9X016 8 8.53 .336 91 61 13.0 5.1 8.7 3.4 2700 600
M9X017 10 9.78 .385 124 83 14.7 5.8 9.8 3.9 2700 600
M9X018 12 11.18 .440 155 104 16.8 6.6 11.2 4.4 2700 600
M9X019 18 11.43 .450 158 106 17.3 6.8 11.4 4.5 2700 600
M9X020 24 14.17 .558 251 169 21.3 8.4 14.2 5.6 2700 600
M9X082 36 15.32 .620 278 187 23.6 9.3 15.7 6.2 2700 600
Part FiberNumber Count mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X005 2 6.60 .260 36 24 9.9 3.9 6.6 2.6 801 180
M9X006 4 7.92 .312 67 45 11.9 4.7 7.9 3.1 1535 345
M9X007 6 9.09 .358 95 64 13.6 5.4 9.1 3.6 2415 543
M9X008 8 10.29 .405 116 78 15.4 6.1 10.3 4.1 2700 600
M9X009 10 11.53 .454 173 116 17.3 6.8 11.5 4.5 2700 600
M9X010 12 13.06 .514 182 122 19.6 7.7 13.1 5.1 2700 600
M9X011 18 13.21 .520 171 115 19.8 7.8 13.2 5.2 2700 600
M9X012 24 14.99 .590 241 162 22.6 8.9 15.0 5.9 2700 600
M9X083 36 17.27 .680 394 265 25.9 10.2 17.3 6.8 2700 600
10
Riser
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.)
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.)
Plenum
Breakout Cables2.0 mm sub-unit – Riser UL/cUL Type OFNR / OFN FT4Plenum UL/cUL Type OFNP / OFN FT6
Recommended Applications• Plenum and Riser cabling• Office cabling• Computer room cabling• 2-12 Fibers per DEC specifications
Product Features• 900 µm tight buffered fibers• Color coded for easy termination• Flame Retardant• UL listed for code compliance• Direct connectorization• Other sub-unit diameters available
Outdoor Direct Burial – Armored
FibersPart Fiber Per
Number Count Tube mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X381 6 6 13.46 .530 196 132 26.9 10.6 20.2 8.0 2700 600
M9X382 12 6 13.46 .530 198 133 26.9 10.6 20.2 8.0 2700 600
M9X384 24 6 13.46 .530 199 134 26.9 10.6 20.2 8.0 2700 600
M9X386 36 6 13.46 .530 201 135 26.9 10.6 20.2 8.0 2700 600
M9X389 48 12 15.49 .610 347 233 31.0 12.2 23.2 9.2 2700 600
M9X391 72 12 15.49 .610 350 235 31.0 12.2 23.2 9.2 2700 600
M9X398 96 12 17.53 .690 397 267 35.1 13.8 26.4 10.4 2700 600
M9X393 144 12 22.10 .870 509 342 44.2 17.4 33.3 13.1 2700 600
M9X400 216 12 22.10 .870 543 365 44.2 17.4 33.3 13.1 2700 600
FibersPart Fiber Per
Number Count Tube mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X510 6 6 9.53 .375 82 55 19.1 7.5 14.3 5.6 2700 600
M9X511 12 6 9.53 .375 83 56 19.1 7.5 14.3 5.6 2700 600
M9X500 24 6 9.53 .375 83 56 19.1 7.5 14.3 5.6 2700 600
M9X502 36 6 9.53 .375 86 58 19.1 7.5 14.3 5.6 2700 600
M9X505 48 12 12.07 .475 124 83 24.1 9.5 18.1 7.1 2700 600
M9X507 72 12 12.07 .475 125 84 24.1 9.5 18.1 7.1 2700 600
M9X513 96 12 13.77 .542 186 125 27.5 10.8 20.7 8.1 2700 600
M9X509 144 12 17.65 .695 368 247 35.3 13.9 26.5 10.4 2700 600
M9X520 216 12 17.65 .695 368 247 35.3 13.9 26.5 10.4 2700 600
11
Outdoor
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.)
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.)
Loose Tube CablesOutdoorOutdoor Direct Burial – Armored
Recommended Applications• Building interconnections• Telecommunications and data trunk• Long haul networking• Direct burial• Applications requiring good ozone, moisture,
weather resistance
Product Features• Excellent attenuation performance• Waterblock gel for moisture protection• Polyethylene jacket for weather and UV protection• Breakout kits available (see page 13)• Corrugated Steel Tape• Rodent Resistant• Dry water blocking available
LOOSE TUBE DETAIL
MOSITURE BLOCKINGGEL
MULTIPLE250 MICRONFIBERS
THERMOPLASTICTUBE
FLOODEDCORE
CENTRALE-GLASSSTRENGTHMEMBER
OUTER JACKETPOLYETHYLENE ARAMID STRENGTH
ELEMENTS
FibersPart Fiber Per
Number Count Tube mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X890 6 6 13.72 .540 240 161 27.4 10.8 20.6 8.1 2700 600
M9X891 12 6 13.72 .540 240 161 27.4 10.8 20.6 8.1 2700 600
M9X892 24 6 13.72 .540 240 161 27.4 10.8 20.6 8.1 2700 600
M9X893 36 6 13.72 .540 240 161 27.4 10.8 20.6 8.1 2700 600
M9X894 48 12 15.75 .620 400 269 31.5 12.4 23.6 9.3 2700 600
M9X895 72 12 15.75 .620 409 275 31.5 12.4 23.6 9.3 2700 600
M9X896 96 12 17.78 .700 521 350 35.6 14.0 26.7 10.5 2700 600
M9X897 144 12 22.35 .880 699 470 44.7 17.6 33.5 13.2 2700 600
FibersPart Fiber Per
Number Count Tube mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X810 6 6 9.65 .380 103 69 19.3 7.6 14.5 5.7 2700 600
M9X811 12 6 9.65 .380 103 69 19.3 7.6 14.5 5.7 2700 600
M9X812 24 6 9.65 .380 103 69 19.3 7.6 14.5 5.7 2700 600
M9X813 36 6 9.65 .380 104 70 19.3 7.6 14.5 5.7 2700 600
M9X814 48 12 12.20 .480 153 103 24.4 9.6 18.3 7.2 2700 600
M9X815 72 12 12.20 .480 153 103 24.4 9.6 18.3 7.2 2700 600
M9X816 96 12 13.89 .547 213 143 27.7 10.9 20.8 8.2 2700 600
M9X817 144 12 17.78 .700 335 225 35.6 14.0 26.7 10.5 2700 600
12
Indoor/Outdoor
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.)
Indoor/Outdoor Direct Burial/Armored
WeightOutside
Diameter Short Term Long TermMax. Load
(Installation)Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.)
Recommended Applications
• Indoor/outdoor building interconnections
• Telecommunications and data trunk
• Long haul networking
• Direct burial
Product Features
• No splicing required at building entrance
• Available with zero-halogen jacket
• Breakout kits available (see page 13)
• Fully waterblocked
RiserLite™Loose Tube CablesIndoor/Outdoor – UL / cUL Type OFNR / OFN FT4Indoor/Outdoor Direct Burial/Armored UL / cUL Type OFCR / OFC FT4
LOOSE TUBE DETAIL
MOSITURE BLOCKINGGEL
MULTIPLE250 MICRONFIBERS
THERMOPLASTICTUBE
FLOODEDCORE
CENTRALE-GLASSSTRENGTHMEMBER
OUTER JACKETPOLYETHYLENE ARAMID STRENGTH
ELEMENTS
Part Number Tube Diameter Fibers/Tube
M90272 0.075" (1.9 mm) ≤ 6
M90273 0.110" (2.8 mm) 7-12
Part FiberNumber Count mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X001 1 2.9 .114 13 9 4.3 1.7 2.9 1.1 400 90
M9X002 2 2.9 x 5.9 .114 x .233 22 15 4.3 1.7 2.9 1.1 801 180
13
Riser
Weight Short Term Long TermMax. Load
(Installation)
Min. Bend Radius
(For “X” in part number see optical characteristics on page 8.)
Field Breakout KitThis Field Breakout Kit is designed to attach to one tube of aloose tube cable and has either six or twelve 900 µm tubesthat hold each of the coated fibers. The kit is available in twosizes to accommodate the two different tube sizes which aremanufactured by Mohawk/CDT.
OutsideDiameter
Part FiberNumber Count mm in. kg/km lbs/M' cm in. cm in. Newtons lbs.
M9X003 1 2.9 .114 13 9 4.3 1.7 2.9 1.1 400 90
M9X004 2 2.9 x 5.9 .114 x .233 22 15 4.3 1.7 2.9 1.1 801 180
Weight Short Term Long TermMax. Load
(Installation)
Min. Bend RadiusOutsideDiameter
Plenum
Simplex & Duplex2.9 mm diameterUL Type OFNR / cUL OFN FT4 UL Type OFNP / cUL OFN FT6
• Patch Cables
• Short run office cabling
• Computer room cabling
Recommended Applications
WorldwideManufacturing andDistribution• Chicago, IL• Houston, TX• Orlando, FL• Leominster, MA• Las Vegas, NV• Los Angeles, CA• Manchester, CT• Memphis, TN• Pittsburgh, PA• Kinna, Sweden• Quebec, Canada
GigaLAN, Cablemate Planner, Q-Scan, LAN-Trak OSP, AdvanceNet, AdvanceLite,MegaLAN, SystemMATE, HomeLAN, UltraLink,MegaLink, GigaLink, AdvanceLink, Cable Caddy, Media Pull, ChannelMate, TruLite,RiserLite, Micro-Loose, FlexLink, Spectrum,Copperhead, ThermoPlen, and QwikConnect are trademarks of Mohawk/CDT.
9 Mohawk Drive, Leominster, MA 01453(978) 537-9961 • 1-800-422-9961 • FAX (978) [email protected]
Mohawk/CDT reserves the right to revise any specificationsin the interest of product enhancement.
©2003 Cable Design Technologies 2/03
Top Related