7/28/2019 08 iSCSI Considerations
1/141PowerEdge M1000e Administration and Configuration
7/28/2019 08 iSCSI Considerations
2/142PowerEdge M1000e Administration and Configuration
7/28/2019 08 iSCSI Considerations
3/143PowerEdge M1000e Administration and Configuration
iSCSI is:
Block level storage
Standards based:
Open standard for SCSI over IP
Ratified by IETF standards committee
iSCSI performs extremely well:
Switched Gb Ethernet outperforms 1Gb Fibre
124 MB/sec per interface
10 Gb-Ethernet iSCSI deployments to be available in the future
iSCSI is a secure, reliable storage
Security built-in to standard (IPSec, VLANs, CHAP)
Multilayer access control (IP address, Initiator, CHAPs)
Switched GbE is point to point, full duplex
iSCSI exploits existing IP knowledge base:
Leverages existing network management tools (SNMP, etc.)
Is a consistent protocol with WAN and LAN infrastructures
Reduces interoperability issues:
IP standards are mature
7/28/2019 08 iSCSI Considerations
4/144PowerEdge M1000e Administration and Configuration
What is iSCSI?
iSCSI defines how storage traffic is handled across a TCP/IP network in the
following suite of RFCs:
RFC 3720 iSCSI
RFC 3721 Naming and Discovery
RFC 3722 String Names
RFC 3723 Securing Block IP Protocols
Provides all the benefits of a SAN:
MPIO, Boot from SAN, Clustering, HBAs, and SAN backup
iSCSI uses a combination of two familiar networking technologies:
Gigabit Ethernet Data Link level protocol to connect between a server and
a level 2 switch:
Uses a MAC address to route between the two
Uses flow control to control the traffic
Uses jumbo frames (9000 byte)
TCP/IP
Routing protocol
Guaranteed delivery system
Storage traffic uses the familiar SCSI protocol to perform SCSI reads and writes to
storage devices from a server
7/28/2019 08 iSCSI Considerations
5/145PowerEdge M1000e Administration and Configuration
iSCSI initiators issue SCSI commands
Commands are Read, Write or Status
Commands are used to request services from components (logical unit known as a
target)
iSCSI targets service the requests from the initiator
iSCSI transmits and receives block storage applications over TCP/IP networks by
encapsulating SCSI commands into TCP and transporting them over the network via IP
iSCSI deployments:
Initial deployments are commonly project-oriented:
Deal with lack of storage for email, databases, and new applications
Provide storage consolidation
Improve the storage management feature set provided by DAS
After initial deployment, SAN becomes infrastructure:
Expanded use for existing applications
New servers and applications
New IT operations
Disk-to-disk backup
Snapshot-based backups
Disaster protection
7/28/2019 08 iSCSI Considerations
6/146PowerEdge M1000e Administration and Configuration
iSCSI requires that the iSCSI initiator and target nodes have one of two types of names.
Name types:
IQN, iSCSI qualified names
Example: iqn.2001-05.com.equallogic:6-8a0900-9f46a0201-
be4ff0d21dd428df-testvoulume1
Format
Reverse DNS naming equallogic.com = com.equallogic
Naming Authority would add a unique string of characters
EUI (enterprise unique identifier)
Example: eui.abcde49123779abcd
Format
Formed using the IEEE EUI (Extended Unique Identifier)
format (16 hex characters)
High 24 bits is the company id, which is IEEE assigned
Low 40 bits is the manufacturer assigned value preceded by
the date that the name was assigned
Both are intended to be long lived and unique.
Both are controlled by a central naming authority such as a department within the
corporation.
The default iSCSI protocol port number is 3260.
7/28/2019 08 iSCSI Considerations
7/147PowerEdge M1000e Administration and Configuration
7/28/2019 08 iSCSI Considerations
8/148PowerEdge M1000e Administration and Configuration
Logging on to the iSCSI target will make the volume visible to this host. To log on to
the target:
From the Targets tab, highlight the target you will attach to
Press the Log On button
When Log On to Target appears, select the Automatically restore this
connection when the system reboots checkbox and press OK
Select the Persistent Targets tab and confirm that the iSCSI name of the
target is listed
7/28/2019 08 iSCSI Considerations
9/149PowerEdge M1000e Administration and Configuration
When a login occurs:
The first login request goes to the PS Series group IP address.
Within the response that is returned to the initiator, there is a Status
class field indicating that the initiator must login to another IP
address. In the case of the PS Series, this IP address will effectively bethe least busy port.
Initially, the login process appears to be round-robin but as traffic
starts to flow, the least busy port or the port with the fewest
connections is chosen.
Then, the initiator is redirected to the least busy port and logs in to that IP
address.
This process of redirection is normal and fully covered in the iSCSI spec.
It is also used in other ways with the PS Series:
If you have a connection to eth2 and if for some reason the switch
port that eth2 is connected to fails, then the initiator will retry thecurrent port briefly, and then attempt to log in to the group IP
address again. Once again, it would be redirected to another port.
While the user may see a brief blip in performance, redirection should
not cause errors.
7/28/2019 08 iSCSI Considerations
10/1410PowerEdge M1000e Administration and Configuration
7/28/2019 08 iSCSI Considerations
11/1411PowerEdge M1000e Administration and Configuration
Network Configuration Choices
Private network
Requires separate switch
Can be inappropriate for some deployments
Separate Subnet/VLAN
Most commonCan use switch level access control for SAN
Port blocking (iSCSI uses port 3260)
Address filtering
LAN (merged LAN and SAN)
May be required with software initiators on desktops or blade servers
WAN
Should be used with VPN or other encryption mechanisms
Network Switch Options
Flow control
Ability of receiver to slow down a sender to avoid packet loss
Unicast storm controlSwitch feature to control storms; must be disabled on SAN ports
Spanning Tree
Switch capability to detect loops in multiple switch configurations
Lengthens time for ports to become usable; should be shortened in SANs (oravoided).
Separate vs. shared subnets (Layer 2 vs. Layer 3)
VLANs allow for separate network traffic while using the same switchinfrastructure
VLANs are separate subnets; adds requirement for L3 switches
Jumbo Frames
Allow larger packet sizes (~9000 bytes vs. 1500 bytes)
Can help improve performance, especially with software initiators
7/28/2019 08 iSCSI Considerations
12/1412PowerEdge M1000e Administration and Configuration
General iSCSI traffic guidelines:
iSCSI traffic tends to be "bursty" with large amounts of data coming all at oncefollowed by idle periods.
The switch needs enough bandwidth to handle the bursts AND enough buffer spaceto buffer packets for other, less fortunate members of the network. Those members
may not able to handle full speed bursts and must use flow control to mitigate theincoming data.
General GE Switch guidelines:
Ideally, the switching fabric should be able to handle 2 Gbps times the number ofports (because the traffic is full duplex). So, a 24-port switch should have an internalspeed of at least 48 Gbps.
For buffer space, a figure of at least 512KB per port seems to be a good startingpoint.
The reason for emphasizing per port is that some switches are designed sothat multiple ports share the same buffer space (and sometimes the samefabric interconnection).
This means that if only one port in this group is passing traffic, then it hasplenty of buffer space and/or bandwidth. As soon as you start passing trafficon multiple ports, and the space and/or bandwidth needs to be dividedamong the ports, there is no longer enough available per port to do the job.
Jumbo frames guidelines:
The maximum frame size that the PS Series can currently handle is 9014 bytes.
Some manufacturers of network equipment call this "9000 bytes"; it dependson whether they count the 14-byte Ethernet header as part of the frame ornot.
We recommend that you not set the jumbo frame size on your switch toanything more than 9014 (or 9000) bytes.
Trunks, ISLs, and Stack cables
Recommend stacking cables if available or if not available then sufficient Trunk, ISLs,to support the load. Rule of thumb is 1 trunk for each active port within the group.
7/28/2019 08 iSCSI Considerations
13/1413PowerEdge M1000e Administration and Configuration
7/28/2019 08 iSCSI Considerations
14/14