Technical Data- viledon MV95 1/1
Particle Removal Efficiency Resistance Curve
Performance Unit MV95Rated Air Flow CFM 1968
Initial Resistance “w.g. .31
Final Resistance “w.g. 1.50
MERV@1968 1-16 16
ASHRAE 52.1 Equivalent Efficiency* % >95%
ASHRAE 52.2BHT-09-1015
Performance Unit MV95Burst Strength) “w.g. >25
ADDITIONAL DATA
MV 95 Characteristic Chart
*Ref. Ashrae 2008 Handbook Chpt.28 Sec. 11
Characteristics unit1/1
(24x24)1/2
(12x24)5/5
(20x20)5/6
(20x24)Header Size in. 23-3/8x23-3/8 11-3/8x23-3/8 19-3/8x19-3/8 19-3/8x23-3/8
Depth 1’’ Recess in. 12-1/2 12-1/2 N/A 12-1/2
Depth Non-Recess in. 11-1/2 11-1/2 11-1/2 11-1/2
Weight lb. 10 5.0 6.5 8.3
Media Area ft2 130.07 56.48 76.76 106.24
0
10
20
30
40
50
60
70
80
90
100
0.1 1 10
Particle Diameter (um)
Rem
oval
Effi
cien
cy %
Initial Load 1 Load 2 Load 3 Load 4 Load 5
0.08
0.15
0.22
0.31
0.41
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
492 984 1476 1968 2460
Air Flow Rate (CFM)
Res
ista
nce
(in W
G)
Freudenberg Filtration Technologies LP2975 Pembroke RoadHopkinsville, Ky 42240Tel: 1-270-887-5145Fax: 1-270-890-0743www.freudenberg-filter.com
The figures given are mean values subject to tolerances due to normal production fluctuations. Our explicit written confirmation is always required for the correctness and applicability of the information involved in any particular case.