ZXMW-PR10 V4 Specification 20080701

20
ZXMW-PR10 V4 PDH Microwave SPECIFICATION

Transcript of ZXMW-PR10 V4 Specification 20080701

Page 1: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave SPECIFICATION

Page 2: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. I

ZXMW-PR10 V4 PDH Microwave Specification

Version Date Author Approved By Remarks

V1.00 2008-06-27 Not open to the Third Party

© 2008 ZTE Corporation. All rights reserved.

ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used without the prior written permission of ZTE.

Due to update and improvement of ZTE products and technologies, information of the document is subjected to change without notice.

Page 3: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

II © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

TABLE OF CONTENTS

1 Overview ......................................................................................................................1 1.1 Key Features ................................................................................................................1 1.2 Advanced Technology..................................................................................................2 1.2.1 FEC-Seed Solomon Technology..................................................................................2 1.2.2 Time Domain Equalizer Technology ............................................................................2

2 Product Description ...................................................................................................3 2.1 Physical Description .....................................................................................................3 2.1.1 Protected Configuration ...............................................................................................3 2.1.2 Unprotected Configuration ...........................................................................................3 2.1.3 Alarm Display ...............................................................................................................3 2.2 ODU..............................................................................................................................3 2.3 IDU ...............................................................................................................................5 2.3.1 1+0 only IDU.................................................................................................................5 2.3.2 1+0 expandable IDU ....................................................................................................6 2.3.3 1+1 protected IDU ........................................................................................................6

3 Network Management System...................................................................................7 3.1 WEB CIT ......................................................................................................................7 3.1.1 Fault Management .......................................................................................................7 3.1.2 Configuration Management..........................................................................................7 3.1.3 Maintenance.................................................................................................................8 3.1.4 Performance.................................................................................................................8 3.1.5 Security Management ..................................................................................................8 3.2 EMS for Microwave Network........................................................................................9

4 Performance Parameters .........................................................................................10 4.1 Frequency Plan and Channel Spacing.......................................................................10 4.2 Nominal Transmitted Power.......................................................................................11 4.3 Threshold Power ........................................................................................................11 4.4 System Gain...............................................................................................................12 4.5 System Characteristics...............................................................................................12 4.6 Ethernet traffic throughput..........................................................................................13 4.7 Power Consumption ...................................................................................................14 4.8 IF Cable Characteristics .............................................................................................14

5 LIST OF ABBREVIATIONS .......................................................................................15

Page 4: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. III

FIGURES

Figure 1 Unprotected ODU (7G - 15G) ...............................................................................................4 Figure 2 Protected ODU (7G - 15G)....................................................................................................4 Figure 3 Unprotected ODU (18G - 38G) .............................................................................................4 Figure 4 Protected ODU (18G - 38G) .................................................................................................5 Figure 5 Remote mounted unprotected ODU (7G – 15G) ..................................................................5 Figure 6 1+0 only 16E1 IDU................................................................................................................5 Figure 7 1+0 only 16E1+Ethernet IDU ................................................................................................5 Figure 8 1+0 Expandable 16E1 IDU ...................................................................................................6 Figure 9 1+0 Expandable 16E1+Ethernet IDU....................................................................................6 Figure 10 1+1 16E1 IDU......................................................................................................................6 Figure 11 1+1 16E1+Ethernet IDU......................................................................................................6 Figure 12 1+1 32E1 IDU......................................................................................................................6 Figure 13 Menu Navigation Bar...........................................................................................................7

TABLES

Table 1 Key Features ..................................................................................................................1 Table 2 Frequency Plan and Channel Spacing.........................................................................10 Table 3 Frequency Plan and Channel Spacing(Continued)......................................................10 Table 4 Transmitted Power .......................................................................................................11 Table 5 Threshold Power ..........................................................................................................11 Table 6 System Gain .................................................................................................................12 Table 7 System Characteristics.................................................................................................12 Table 8 System Characteristics(Continued)..............................................................................13 Table 9 Ethernet Maximum Throughput....................................................................................14 Table 10 Power Consumption .....................................................................................................14 Table 11 IF Cable Characteristics ...............................................................................................14

Page 5: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 1

1 Overview ZXMW-PR10 is PDH family of digital microwave systems by ZTE Corporation. It leads the market in technology innovation, network flexibility, and IP evolution.

ZXMW-PR10 is a versatile, compact split type radio system. It supports both data and voice transmission, typically in mobile RAN, backhaul, enterprise, government, and public safety networks. It is optimized for combined PDH-IP operation in next generation wireless networks.

ZXMW-PR10 PDH supports frequency bands from 7 to 38 GHz and supports 32xE1 telephony or 16xE1 telephony with 4x10/100Base-T data interfaces. Software selectable QPSK or 16QAM modulation provides bandwidth range from 3.5 to 28MHz for 4E1 to 32E1. ZXMW-PR10 is developed for low-to-medium capacity PDH access and transport.

1.1 Key Features This section introduces the key features of ZXMW-PR10 microwave systems. The main frequency bands, capacity, modulation and capacity are listed in Table 1 .

Table 1 Key Features

Frequency Band 7, 8, 13, 15, 18, 23, 26, 38GHz

Capacity Mixed capacity 4 to 32E1 or LAN interface 4Mbps to 75Mbps

Modulation QPSK, 16QAM Configuration 1+0 Only, 1+0 Expandable, 1+1

The detail description is as follows.

• Capacity independent ODU

• 4E1,8E1,16E1,32 E1 selectable

• 4x10/ 100Base-T ports with built-in Layer-2 Ethernet Switch

• Fully programmable modem

• In-service performance monitoring with parameters compliant to ITU-T G.826 recommendations

• Self diagnostics to differentiate the path alarms from the equipment alarms

• Built-in SNMP support

• Programmable relay contacts for alarm indication or site control

• Web CIT for radio maintenance

Page 6: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

2 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

• Remote baseband loop back

• Local baseband loop back

• ATPC operation

Ethernet port supports:

• 10M/100M/Full duplex/Half duplex auto-negotiation

• Flow control

• Frame size up to 1518 bytes

• MDI/MDI-X self-adaptive

• IP frame direct mapping to radio frame, low latency and high throughput

• Max throughput up to 75Mbps(1+0 expandable,1+1) or 40Mbps(1+0 only)

• VLAN Transparent (IEEE802.1Q Tagged frame) / VLAN Tagging

1.2 Advanced Technology The following advanced technologies are used in ZXMW-PR10 Digital microwave system design.

1.2.1 FEC-Seed Solomon Technology

ZXMW-PR10 PDH System adopts twice accessional FEC coding technology. To build (252, 236) RS coding which is first FEC coding, 16 byte RS code was tacked after 236 byte. This is known as RS coding External code. The second accessional FEC coding adopts Convolution Coder. This is known as Convolution Coder Internal code. Based on this design, ZXMW-PR10 PDH System gets more system gain with less coding length.

1.2.2 Time Domain Equalizer Technology

In ZXMW-PR10 PDH system, time-domain equalizer consists of two parts, a Feed Forward section and Decision Feedback section. The Feed Forward section is a 24-tap, fractionally-spaced FIR filter. The filter coefficients can be driven by a blind CMA algorithm during acquisition or by a decision directed algorithm once carrier lock is achieved. A 3-tap decision feedback filter is used within the carrier recovery loop to correct strong minimum-phase distortions.

Page 7: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 3

2 Product Description

2.1 Physical Description The ZXMW-PR10 PDH radio system consists of IDU (Indoor Unit) and ODU (Outdoor Unit). The IDU can be mounted in the standard 19” (483 mm) rack occupying 1U space both for unprotected and 1+1 protected configuration. The ODU is weatherproof and can be mounted in separate or direct mode with antenna.

The radio is fully programmable in terms of capacity, modulation level, RF frequency channel, and transmit output power level.

2.1.1 Protected Configuration

ZXMW-PR10 supports HSB&SD protection modes.

HSB consists of 1+1 IDU and two ODUs mounted on hybrid.

SD consists of one 1+1 IDU and two ODUs.

2.1.2 Unprotected Configuration

A ZXMW-PR10 terminal in an unprotected configuration consists of 1+0 IDU and one ODU connected to the IDU Modem through a coaxial cable.

2.1.3 Alarm Display

In-service performance monitoring and built-in diagnostics are provided to monitor signal quality, path identification and hardware failures. LED’s and relay contacts provide alarm status. The ZXMW-PR10 PDH supports Network Management System (NMS) and element management system with SNMP protocol.

2.2 ODU Suitable configuration can be selected from various ODU mounting styles.

• Direct mounting on antenna

• Separate mounting with antenna using flexible waveguide

• 1+1 mode with Hybrid

The unprotected and protected modes are shown from Figure1 to Figure5.

Page 8: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

4 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

Figure 1 Unprotected ODU (7G - 15G)

Figure 2 Protected ODU (7G - 15G)

Figure 3 Unprotected ODU (18G - 38G)

Page 9: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 5

Figure 4 Protected ODU (18G - 38G)

Figure 5 Remote mounted unprotected ODU (7G – 15G)

2.3 IDU

2.3.1 1+0 only IDU

The IDU 1+0 only configuration is shown in Figure6 and Figure7.

Figure 6 1+0 only 16E1 IDU

Figure 7 1+0 only 16E1+Ethernet IDU

Page 10: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

6 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

2.3.2 1+0 expandable IDU

The IDU 1+0 expandable configuration is shown in Figure8 and Figure9.

Figure 8 1+0 Expandable 16E1 IDU

Figure 9 1+0 Expandable 16E1+Ethernet IDU

* 1+0 Expandable IDU can update to 1+1 IDU

2.3.3 1+1 protected IDU

The IDU 1+1 protected configuration is shown in Figure10 to Figure12.

Figure 10 1+1 16E1 IDU

Figure 11 1+1 16E1+Ethernet IDU

Figure 12 1+1 32E1 IDU

Page 11: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 7

3 Network Management System

3.1 WEB CIT ZXMW-PR10 has Web CIT interface for Local/Remote end maintenance, configuration, and troubleshooting.

The CIT (Craft Interface Terminal) is a Web-Based Management System. All system features are provided by Embedded RTOS and VxWorks. C is employed as programming languages.

Web CIT operates on Microsoft Internet Explorer (IE), and connect to front panel of IDU by a network cable, no additional client software required.

The menu navigation bar is shown in Figure13.

Figure 13 Menu Navigation Bar

The options listed in sub menu are describes as follows.

3.1.1 Fault Management

All alarms are displayed in fault management page. Alarms data can be monitored and retrieved easily.

3.1.2 Configuration Management

Web CIT provides local/remote end configuration. User can configure following configuration parameters.

• E1 Used Capability

• Band Width

• Modulation Type

Page 12: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

8 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

• Wireless Network Capability

• Protection mode

• System Time

• Frequency

• TPC (transmit power control) and ATPC

• Software version

• IP address

• Tributary management

User can configure frequency, and the adjustable step is 250 kHz.

User can configure transmit power, and the adjustable step is 1 dB.

3.1.3 Maintenance

Web CIT provides following maintenance tools

• MU Tone

• Reboot

• Upgrade

• Loopback

Loopback function includes two modes:

• Local End Baseband Loop Back

• Remote End Baseband Loop Back

3.1.4 Performance

Web CIT provides System BER (Bit Error Rate) measurement, and total performance statistics with different level.

3.1.5 Security Management

Web CIT provides SNMP Management, Trap Destinations Management, User Management, and Password Management.

Page 13: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 9

3.2 EMS for Microwave Network The Element Management System is located at a central or a region operation center and enables operators to monitor and control the ZXMW family microwave products.

ZXMW-EMS is a low-cost yet powerful and comprehensive management tool for ZTE PDH/SDH product lines. ZXMW-EMS offers full functionality through a friendly and intuitive graphical user interface. Running on an ordinary PC under Windows 2003/ XP and supporting industry-standard protocols such as SNMP.

Page 14: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

10 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

4 Performance Parameters The performance parameters of ZXMW-PR10 are described in this chapter.

4.1 Frequency Plan and Channel Spacing The frequency plan and Channel separation is listed in Table 2 and Table 3 .

Table 2 Frequency Plan and Channel Spacing

Item 7 GHz 8 GHz 13 GHz 15GHz Frequency Range [GHz] 7.11-7.9 7.725-8.5 12.75-13.25 14.5-15.35

Frequency Plan ITU-R/CEPT

F.385-7 Annex 1 Annex 4 CEPT/ERC REC 02-06

F.386-6 Annex 1 Annex 3 Annex 4

F.497-6 CEPT/ERC REC12-02

F.636-3 CEPT/ERC REC12-07

Channel Separation

QPSK: 7MHz/4E1, 14MHz/8E1, 28MHz/16E1 16QAM: 3.5MHz/4E1, 7MHz/8E1, 14MHz/16E1, 28MHz/32E1

RF TX/RX Spacing [MHz]

154, 161 168,196, 245

119,126 305.56 311.32

266 420, 490, 728

Table 3 Frequency Plan and Channel Spacing(Continued)

Item 18 GHz 23 GHz 26 GHz 38 GHz Frequency Range [GHz] 17.7-19.7 21.2-23.6 24.5-26.5 37.0-39.5

Frequency Plan ITU-R/CEPT

F.595-6 F.191 CEPT/ERC REC12-03

F.637-3 CEPT/ERC REC T/R 13-02 Annex A

F.748-3 CEPT/ERC REC T/R 13-02 Annex B

F.749-1 CEPT/ERC REC T/R 12-01

Channel Separation

QPSK: 7MHz/4E1, 14MHz/8E1, 28MHz/16E1 16QAM: 3.5MHz/4E1, 7MHz/8E1, 14MHz/16E1, 28MHz/32E1

RF TX/RX Spacing [MHz] 1010 1008 1008 1260

Page 15: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 11

4.2 Nominal Transmitted Power The nominal transmitted power with different modulation schemes is listed in Table 4 .

Table 4 Transmitted Power

Frequency(GHz) 7 8 13 15 18 23 26 38 Guaranteed

QPSK 24.0 24.0 21.0 21.0 20.0 20.0 20.0 17.0 Output Power (dBm) 16QAM 20.0 20.0 17.0 17.0 15.0 15.0 15.0 13.0

±2.0 dB

4.3 Threshold Power The threshold power in dBm measured at antenna port is listed in Table 5 .

Table 5 Threshold Power

Frequency(GHz) 7 8 13 15 18 23 26 38 Guaranteed

16E1 -86.0 -85.5 -85.5 -85.5 -85.5 -84.5 -84.0 -83.5

8E1 -88.5 -88.0 -88.5 -88.5 -87.5 -86.5 -86.0 -85.5 QPSK

4E1 -91.5 -91.0 -91.0 -91.0 -90.0 -89.5 -89.0 -88.5

32E1 -78.0 -78.0 -77.0 -77.0 -76.0 -75.0 -74.5 -74.0

16E1 -84.0 -83.5 -83.5 -83.5 -82.5 -82.5 -82.0 -81.5

8E1 -86.5 -86.0 -86.0 -86.0 -85.0 -84.0 -84.5 -83.0

BER = 10-3

16QAM

4E1 -88.5 -88.0 -88.5 -88.5 -87.5 -86.5 -86.0 -85.5

16E1 -82.5 -82.0 -82.0 -82.0 -81.0 -80.0 -79.5 -79.0

8E1 -85.0 -84.5 -85.0 -85.0 -84.0 -83.0 -82.5 -82.0 QPSK

4E1 -88.0 -87.5 -87.5 -87.5 -87.0 -86.0 -85.5 -85.0

32E1 -74.0 -74.0 -73.0 -73.0 -72.5 -72.0 -71.5 -71.0

16E1 -80.5 -80.0 -80.0 -80.0 -77.0 -76.0 -75.5 -75.0

8E1 -83.0 -82.5 -82.5 -82.5 -80.0 -79.0 -78.5 -78.0

BER = 10-6

16QAM

4E1 -85.0 -84.5 -85.0 -85.0 -83.0 -82.0 -81.5 -81.0

+2.0 dB

Page 16: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

12 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

4.4 System Gain The system gain in dBm measured at antenna port is listed in Table 6 .

Table 6 System Gain

Frequency(GHz) 7 8 13 15 18 23 26 38 Guaranteed

16E1 110.0 109.5 106.5 106.5 105.5 104.5 104.0 100.5

8E1 112.5 112.0 109.5 109.5 107.5 106.5 106.0 102.5 QPSK

4E1 115.5 115.0 112.0 112.0 110.0 109.5 109.0 105.5

32E1 98.0 98.0 94.0 94.0 91.0 90.0 89.5 87.0

16E1 104.0 103.5 100.5 100.5 97.5 97.5 97.0 94.5

8E1 106.5 106.0 103.0 103.0 100.0 99.0 99.5 96.0

BER = 10-3

16QAM

4E1 1085 108.0 105.5 105.5 102.5 101.5 101.0 98.5

16E1 106.5 106.0 103.0 103.0 101.0 100.0 99.5 96.0

8E1 109.0 108.5 106.0 106.0 104.0 103.0 102.5 99.0 QPSK

4E1 112.0 111.5 108.5 108.5 107.0 106.0 105.5 102.0

32E1 94.0 94.0 90.0 90.0 87.5 87.0 86.5 84.0

16E1 100.5 100.0 97.0 97.0 92.0 91.0 90.5 88.0

8E1 103.0 102.5 99.5 99.5 95.0 94.0 93.5 91.0

BER = 10-6

16QAM

4E1 105.0 104.5 102.0 102.0 98.0 97.0 96.5 94.0

-3.0 dB

4.5 System Characteristics

Table 7 System Characteristics

Frequency(GHz) 7 8 13 15 18 23 26 38 Guaranteed

ATPC range 20 dB, in 1 dB step -

Frequency Stability ±5 ppm ±10 ppm

Configuration 1+0 only, 1+0 Expandable, 1+1(HS), 1+1(HS/SD)

Receiver Noise Figure (at Ant. port) dB 4.5 4.5 4.5 4.5 5.5 6.5 7.0 7.5

+2 dB (13/15/18G) +1.5 dB (23/38G)

Maximum Input Level -20 dBm (No Error) -

Metering Access RX Signal Level -

Page 17: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 13

Table 8 System Characteristics(Continued)

Item Specification Modulation Type QPSK / 16QAM

*Baseband Interface N×E1 (N=0/4/8/16/32) + 4×10/100 Base T(X)

E1 (ITU-T G.703) 10/100 Base T(X) (IEEE 802.3)

Service Channels G.703 (Co-directional) 64kbps × 1 channel Engineering Order Wire × 1 channel 2 inputs and 2 outputs

External alarms Connector type : 15 pins, D-SUB

Loop Back Far/Near End Baseband Loop Back

Spectrum shaping Root roll-off ( α=0.2 )

Residual BER Less than 10-12 at RSL = -30 dBm

ODU Monitor Items Metering access Received signal level (AGC V) Output power level (TX PWR)

LED Display

Operating PWR (Green) IDU Alarm (Red/Major, Yellow/Minor) ODU Alarm (Red/Major, Yellow/Minor) Maintenance (Yellow, Flash)

EMC Conforms to ETS 301 489-4

Mean Time Between Failures (MTBF) 200,000 Hours

Guaranteed Temperature Range

IDU: -5 to 45°C; ODU: -33 to +55°C

Dimensions (mm) and Weight

7-15G ODU: 230 (W) × 305 (H) × 102 (D); 5.2 Kg 18-38G ODU: 210 (W) × 290 (H) × 90 (D); 5.0 Kg IDU 1+0: 482 (W) × 44 (H) × 240 (D); 3.0 Kg IDU 1+1: 482 (W) × 44 (H) × 240 (D); 3.7 Kg

*Note:

i When the N=32, ETH traffic is unavailable

ii If the T1 traffic required, the equipment should be ordered separately.

4.6 Ethernet traffic throughput The maximum throughput in Mbps measured when bandwidth is dedicated for ETH traffic use is listed in Table 9 .

Page 18: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

14 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

Table 9 Ethernet Maximum Throughput

Note: Effective traffic throughput depends on modulation and packet size.

4.7 Power Consumption

Table 10 Power Consumption

4.8 IF Cable Characteristics

Table 11 IF Cable Characteristics

Item Specification Interconnection Single coaxial cable (per channel)

Standard Type of Cable 8D-FB, RG-8 and equivalent Signals IF signal, alarms, control, monitoring, power

source Maximum Cable Length 300m(QPSK), 200m(16QAM)

Cable Equalization Automatic level equalization Guaranteed temperature range

-33°C to +50°C (workable : -40°C to +55°C)

QPSK 16QAM Configuration

3.5MHz 7MHz 14MHz 28MHz 3.5MHz 7MHz 14MHz 28MHz

1+0 only 4Mbps 10Mbps 21Mbps 40Mbps 10Mbps 21Mbps 40Mbps 40.00Mbps

1+0 Expandable /1+1

5Mbps 10Mbps 21Mbps 42Mbps 10Mbps 21Mbps 42Mbps 75Mbps

Power Consumption ( at -48 VDC Input) Power Supply -40 to -58 VDC Configuration 1 + 0 1 + 1 IDU 20W (Rate Free) 45W (Rate free)

ODU 35W 35W×2 E1 TU 1.4W

Option Card ETH TU 1W

Power consumption 55W 115W

Page 19: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

ZTE Confidential Proprietary © 2008 ZTE Corporation. All rights reserved. 15

5 LIST OF ABBREVIATIONS Typeface Meaning

AGC Automatic Gain Control

A/D Analog-to-Digital

AIS Alarm indication signal ALM Alarm AMP Amplifier ANT Antenna

ATPC Automatic Transmitter Power Control BBE Background Block Error BER Bit Error Rate BNC Bayonet Navy Connector

BR Branching CIT Craft Interface Terminal CMA Constant Modulus Algorithm CONV Converter

D/A Digital-to-Analog DEM Demodulator DEMUX Demultiplexer DHCP Dynamic Host Configuration Protocol

DPLL Digital Phased Locked Loop DSC Digital Service Channel EDI External Device Interface EMC Electro Magnetic Compatibility

EMS Element Management System EOW Engineering Order Wire ES Erred Seconds ETH Ethernet

ETSI European Telecommunications Standards Institute FIR Finite Impulse Response FREQ Frequency FTP File Transfer Protocol

HDB3 High Density Bipolar of order 3 HDLC High level Data Link Control HSB Hot Standby HTTP Hyper Text Transfer Protocol

IEC International Electro technical Commission

Page 20: ZXMW-PR10 V4 Specification 20080701

ZXMW-PR10 V4 PDH Microwave Specification

16 © 2008 ZTE Corporation. All rights reserved. ZTE Confidential Proprietary

Typeface Meaning I/O Input/Output

IDU Indoor Unit IF Intermediate Frequency ITU International Telecommunication Union ITU-R Radio standardization sector of ITU

ITU-T Telecommunication standardization sector of ITU LAN Local Area Network LED Light Emitting Diode LNA Low Noise Amplifier

LOF Loss of Frame LOS Loss of Signal MAINT Maintenance MIB Management Information Base

MIC Microwave Integrated Circuit MDI/MDI-X Media Dependent Interface MOD Modulator MTBF Mean time Between Failure

MUX Multiplexing NE Network Element NMS Network Management System NRZ Non-Return to Zero coding ODU Outdoor Unit

OSPF Open Shortest Path First PC Personal Computer PDH Plesiochronous Digital Hierarchy ppm parts per million

PS Power Supply PWR Power QAM Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying

RF Radio Frequency RX Receiver SD Space Diversity SES Severely Erred Second

SNMP Simple Network Management Protocol TX Transmitter