Zurich Open Repository and Archive University of Zurich Main Library Strickhofstrasse 39 CH-8057 Zurich www.zora.uzh.ch Year: 2015 Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study. Ioannidis, Alexis ; Gallucci, German O ; Jung, Ronald E ; Borzangy, Sary ; Hämmerle, Christoph H F ; Benic, Goran I Abstract: AIM To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently from titanium (Ti) 4.1 mm diameter implants with respect to marginal bone level (MBL) and clinical parameters. MATERIAL AND METHODS Forty patients in need of a single-implant crown in the anterior or premolar regions were enrolled in two centres. Following random allocation, either a Ti-Zr or a Ti implant was inserted. Porcelain-fused-to-metal crowns were inserted 6 months after implantation. Implant survival, change in MBL, clinical parameters, change in mid-facial mucosa and papilla levels, and the occurrence of biological and technical complications were assessed at the 3-year follow-up. RESULTS At 3 years, 32 of the 40 included patients were examined (15 Ti, 17 Ti-Zr). There were no implant failures. From the implant placement to 3 years, the median change in mean MBL amounted to 0.21 mm (mean: -0.31) in the Ti group and 0.10 mm (mean: -0.40) in the Ti-Zr group. There were no significant differences between the groups with respect to the change in MBL, the change in mucosa levels, and the occurrence of complications. CONCLUSIONS Ti-Zr implants with 3.3 mm diameter used for the support of single crowns in the anterior and the premolar regions did not differ from Ti implants with 4.1 mm diameter regarding the clinical performance over a 3-year period. This article is protected by copyright. All rights reserved. DOI: https://doi.org/10.1111/jcpe.12468 Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: https://doi.org/10.5167/uzh-113483 Journal Article Accepted Version Originally published at: Ioannidis, Alexis; Gallucci, German O; Jung, Ronald E; Borzangy, Sary; Hämmerle, Christoph H F; Benic, Goran I (2015). Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study. Journal of Clinical Periodontology, 42(11):1060-1070. DOI: https://doi.org/10.1111/jcpe.12468

Transcript of Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether...

Page 1: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

Zurich Open Repository andArchiveUniversity of ZurichMain LibraryStrickhofstrasse 39CH-8057 Zurichwww.zora.uzh.ch

Year: 2015

Titanium-zirconium narrow-diameter versus titanium regular-diameterimplants for anterior and premolar single crowns: 3-year results of a

randomized controlled clinical study.

Ioannidis, Alexis ; Gallucci, German O ; Jung, Ronald E ; Borzangy, Sary ; Hämmerle, Christoph H F ;Benic, Goran I

Abstract: AIM To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differentlyfrom titanium (Ti) 4.1 mm diameter implants with respect to marginal bone level (MBL) and clinicalparameters. MATERIAL AND METHODS Forty patients in need of a single-implant crown in theanterior or premolar regions were enrolled in two centres. Following random allocation, either a Ti-Zr ora Ti implant was inserted. Porcelain-fused-to-metal crowns were inserted 6 months after implantation.Implant survival, change in MBL, clinical parameters, change in mid-facial mucosa and papilla levels, andthe occurrence of biological and technical complications were assessed at the 3-year follow-up. RESULTSAt 3 years, 32 of the 40 included patients were examined (15 Ti, 17 Ti-Zr). There were no implantfailures. From the implant placement to 3 years, the median change in mean MBL amounted to 0.21 mm(mean: -0.31) in the Ti group and 0.10 mm (mean: -0.40) in the Ti-Zr group. There were no significantdifferences between the groups with respect to the change in MBL, the change in mucosa levels, and theoccurrence of complications. CONCLUSIONS Ti-Zr implants with 3.3 mm diameter used for the supportof single crowns in the anterior and the premolar regions did not differ from Ti implants with 4.1 mmdiameter regarding the clinical performance over a 3-year period. This article is protected by copyright.All rights reserved.

DOI: https://doi.org/10.1111/jcpe.12468

Posted at the Zurich Open Repository and Archive, University of ZurichZORA URL: https://doi.org/10.5167/uzh-113483Journal ArticleAccepted Version

Originally published at:Ioannidis, Alexis; Gallucci, German O; Jung, Ronald E; Borzangy, Sary; Hämmerle, Christoph H F;Benic, Goran I (2015). Titanium-zirconium narrow-diameter versus titanium regular-diameter implantsfor anterior and premolar single crowns: 3-year results of a randomized controlled clinical study. Journalof Clinical Periodontology, 42(11):1060-1070.DOI: https://doi.org/10.1111/jcpe.12468

Page 2: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

1

Titanium-zirconium narrow-diameter versus titanium regular-1

diameter implants for anterior and premolar single crowns: 3-2

year results of a randomized controlled clinical study 3

Alexis Ioannidis1, German O. Gallucci2, Ronald E. Jung1, Sary Borzangy2, 3, Christoph H.F. 4

Hämmerle1, Goran I. Benic1 5

6

1: Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of 7

Dental Medicine, University of Zurich, Zurich, Switzerland 8

2: Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental 9

Medicine, Boston, USA 10

3: Department of Substitutive Dental Sciences, College of Dentistry, Taibah University, Al 11

Madinah Al Munawwarah, Kingdom of Saudi Arabia 12

13

Key words: dental implants, titanium-zirconium, titanium, narrow, diameter, crown, fixed 14

partial denture, humans, randomized controlled trial, survival, radiographic 15

Running title: Ti-Zr narrow- vs. Ti regular-diameter 16

17

Address for correspondence: Dr. Goran I. Benic 18 Clinic of Fixed and Removable Prosthodontics and Dental 19 Material Science 20 Center of Dental Medicine 21 University of Zurich 22 Plattenstrasse 11 23 8032 Zurich, Switzerland 24 Tel: +41 44 634 32 52 25 Fax: +41 44 634 43 05 26 E-mail: [email protected] 27

Page 3: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

2

Abstract 1

Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 2

from titanium (Ti) 4.1 mm diameter implants with respect to marginal bone level (MBL) and 3

clinical parameters. 4

Material and Methods: Forty patients in need of a single-implant crown in the anterior or 5

premolar regions were enrolled in two centres. Following random allocation, either a Ti-Zr or 6

a Ti implant was inserted. Porcelain-fused-to-metal crowns were inserted 6 months after 7

implantation. Implant survival, change in MBL, clinical parameters, change in mid-facial 8

mucosa and papilla levels, and the occurrence of biological and technical complications were 9

assessed at the 3-year follow-up. 10

Results: At 3 years, 32 of the 40 included patients were examined (15 Ti, 17 Ti-Zr). There 11

were no implant failures. From the implant placement to 3 years, the median change in mean 12

MBL amounted to 0.21 mm (mean: -0.31) in the Ti group and 0.10 mm (mean: -0.40) in the 13

Ti-Zr group. There were no significant differences between the groups with respect to the 14

change in MBL, the change in mucosa levels, and the occurrence of complications. 15

Conclusions: Ti-Zr implants with 3.3 mm diameter used for the support of single crowns in 16

the anterior and the premolar regions did not differ from Ti implants with 4.1 mm diameter 17

regarding the clinical performance over a 3-year period. 18

19

20

21 22

Page 4: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

3

Introduction 1

Placing dental implants into native bone or in conjunction with bone augmentation 2

procedures is a predictable treatment option to prosthetically restore the edentulous jaw 3

regions (Jung et al., 2012, Benic et al., 2009, Hammerle et al., 2002). Due to the reduced 4

bucco-oral dimension of the edentulous alveolar ridge, the prosthetically driven implant 5

placement is frequently associated with the presence of peri-implant bone dehiscences and 6

fenestrations. In terms of mesio-distal gap dimension, an adequate distance between teeth 7

and implants is required to reduce the amount of subsequent bone resorption and recession 8

of the papillae (Esposito et al., 1993, Tarnow et al., 2000). The challenging clinical situations 9

with limited mesio-distal amount of space or reduced ridge width can be overcome by using 10

narrow-diameter implants (Davarpanah et al., 2000). 11

A recent systematic review of clinical trials found survival rates of narrow-diameter 12

(3.0 – 3.5 mm) implants ranging from 89% to 100% (Klein et al., 2014). The meta-analysis of 13

the data showed no statistically significant differences in implant survival between implants 14

with 3.3 – 3.5 mm diameter and those with conventional diameter (3.75 – 4.1 mm). It was, 15

however, found that there is insufficient evidence on the success rates for implants with 16

narrow diameter (Klein et al., 2014). It is known that fatigue fractures of narrow-diameter 17

implants may occur after a long period of loading (Zinsli et al., 2004). The risk of 18

biomechanical problems and the limited knowledge of their clinical behaviour should, 19

therefore, be taken into account when using implants with narrow diameter (Bornstein et al. 20

2014). 21

The strength of titanium (Ti) implants can be increased, by alloying Ti with other 22

metals, such as zirconium (Kobayashi et al., 1995, Grandin et al., 2012). A titanium-23

zirconium (Ti-Zr) alloy, made of 83-87% Ti and 13-17% Zr, was developed and introduced for 24

the fabrication of narrow-diameter implants (Berner et al., 2009). Preclinical investigations 25

revealed that Ti-Zr implants perform similar to Ti implants with respect to osseointegration 26

(Thoma et al., 2011, Gottlow et al., 2012, Saulacic et al., 2012, Anchieta et al., 2013, Wen et 27

al., 2013). 28

Page 5: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

4

The clinical performance of narrow-diameter Ti-Zr implants was investigated in 1

several previous clinical trials (Chiapasco et al., 2012, Benic et al., 2013, Anchieta et al., 2

2013) In those studies high survival and success rates for Ti-Zr narrow-diameter implants 3

were observed after short periods of observation. A recent randomized controlled trial 4

compared narrow-diameter Ti-Zr and Ti implants for the support of mandibular overdentures 5

(Al-Nawas et al., 2012). In this study no differences were found between Ti-Zr and Ti 6

implants with respect to the change in marginal bone level (MBL), the implant survival and 7

the success rate after 3 years of observation (Quirynen et al., 2014). However, there is 8

insufficient comparative evidence available on the clinical performance of narrow-diameter 9

Ti-Zr implants for the support of fixed partial dentures in the load bearing jaw regions. 10

Therefore, the primary aim of the present randomized controlled clinical trial was to 11

test whether Ti-Zr 3.3 mm diameter implants, placed to support single crowns in the anterior 12

and the premolar regions, render different results from Ti 4.1 mm diameter implants with 13

respect to the change in MBL over a 3-year period. The null hypothesis was that the 14

treatment modalities do not differ with respect to the change in MBL from the implant 15

placement to the 3-year follow-up. In addition, the implant survival, the soft tissue parameters 16

and the complication rate were assessed. 17

18

Page 6: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

5

Material and Methods 1

This article is reported according to the CONSORT guidelines for reporting parallel 2

group randomized trials (Moher et al., 2010). 3

4

Study design 5

This study was designed as a prospective randomized controlled clinical trial with two 6

parallel study groups and a duration period of 5 years. The study was conducted at two 7

centres (Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center 8

of Dental Medicine, University of Zurich, Zurich, Switzerland and Department of Restorative 9

Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA, USA). 10

The clinical protocol was approved by the respective local ethical committees. 11

12

Study population 13

Each centre recruited 20 subjects for a total of 40 patients in need of an implant-14

supported crown for the restoration of a single-tooth gap in the anterior or the premolar 15

regions of upper or lower jaw. 16

The subjects had to fulfil the following inclusion criteria: 17

• ≥18 years of age 18

• No medical history in which any elective oral surgical intervention would be 19

contraindicated 20

• No heavy smoking (>20 cigarettes per day) 21

• No active periodontal disease 22

• Full-mouth plaque score (FMPS) and full-mouth bleeding score (FMBS) <25% 23

• Need of an implant-supported crown at a single-tooth gap in regions 11–15, 21–25, 31–24

35, 41–45 (FDI) 25

• Presence of mesial and distal natural teeth 26

Page 7: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

6

• Adequate quantity of native bone to allow the placement of an implant with 4.1 mm 1

diameter and 8 mm length with at least 2 mm of distance to the mandibular alveolar canal. 2

The pre-operative assessment of the apico-coronal amount of bone available was 3

performed by means of a panoramic radiograph. 4

Need of primary bone augmentation and absence of primary stability at the time of 5

implant placement were considered exclusion criteria. 6

A signed informed consent was obtained from all the patients prior to any study 7

treatments. 8

9

Randomization and allocation concealment 10

All patients were randomly allocated to one of the two treatment modalities according 11

to a computer-generated randomization list. Two separated lists were created for the two 12

study centers. To generate the allocation sequence, a permuted-block randomization with 13

block sizes of 4 and allocation ratio of 1:1 was applied. In the case that two or more sites per 14

patient were available, fulfilling the inclusion criteria, one gap was selected by throwing a die. 15

Allocation to the study groups was concealed by using sealed envelopes until the time of 16

surgical procedure that required the preparation of the implant bed. 17

18

Treatment procedures 19

The time sequence of interventions and assessments is represented in Fig. 1. All 20

investigators participating in the study were experienced in implant placement and bone 21

augmentation procedures. Before the study initiation, all participating clinicians attended a 22

training session to standardize the patient selection and the therapeutic procedure and to 23

calibrate the assessment techniques. 24

The placement of implants was performed either as type 2, type 3 or type 4 procedure 25

(Hammerle et al., 2004). Prior to implant insertion, the patients received antibiotics (2 x 750 26

mg amoxicillin) and non-steroidal analgesics/antiphlogistics. The surgery was performed 27

under local anaesthesia. A crestal incision and, if needed, a vertical release incision were 28

Page 8: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

7

performed and the mucoperiostal flaps were elevated. In the case that the amount of bone 1

was found to be insufficient for implant placement, the patient was considered ineligible for 2

the study and an alternative treatment following good clinical standards was offered. The 3

implant bed was prepared according to the manufacturer’s instruction for the placement of 4

StraumannⓇ Bone Level implants (Institut Straumann AG, Basel, Switzerland). 5

One of the following randomly assigned implants was inserted: 6

• Test group: a Ti-Zr 3.3 mm diameter implant (StraumannⓇ Bone Level, RoxolidⓇ, 7

SLActiveⓇ, Institut Straumann AG) 8

• Control group: a Ti 4.1 mm diameter implant (StraumannⓇ Bone Level, Ti, SLActiveⓇ, 9

Institut Straumann AG). 10

11

The implant stability was assessed by mechanical testing with a hand instrument (e.g. 12

periodontal probe). In the event that the implant lacked primary stability (visible mobility on 13

mechanical testing), the subject was excluded from the study and an alternative treatment 14

was offered following good clinical standards. Peri-implant bone dehiscences, fenestrations, 15

infrabony defects measuring >0.5 mm of width, and thin bone plates were grafted with 16

particulated deproteinized bovine bone mineral (BioOssⓇ Spongiosa Granules; Geistlich 17

Pharma AG, Wolhusen, Switzerland) and covered with a native collagen membrane 18

(BioGideⓇ; Geistlich Pharma AG). If needed, the membrane was fixed by using resorbable 19

pins (Inion GTRTM, Inion Ltd., Tampere, Finland). A cover screw was placed and the mucosal 20

flaps were sutured using ePTFE non-resorbable monofilament sutures (Gore-TexⓇ, Gore, 21

Flagstaff, AZ, USA). All the implants healed in a submerged position. The patients were 22

instructed to rinse the oral cavity twice daily with 0.2% chlorhexidine-digluconate and 23

analgesics (mefenamic acid 500 mg) were prescribed for the first 3 days according to the 24

individual needs. In cases of guided bone regeneration, the patients received antibiotics for 5 25

days (3 x 750 mg/day amoxicillin). The sutures were removed 7 days after implant 26

Page 9: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

8

placement. Post-surgical examinations including supra-gingival cleaning were performed 2 1

and 6 weeks after implant insertion. 2

Three months after the implant placement, the re-entry surgery was performed under local 3

anaesthesia. After crestal incision and flap elevation, cover screws were replaced by healing 4

abutments. When necessary, provisional crowns were inserted to condition the peri-implant 5

soft tissue. The final porcelain-fused-to-metal single screw- or cement-retained crowns were 6

placed 6 months after the implantation. All the patients were recalled for the follow-up 7

assessment 1 and 3 years after the implant placement (Fig. 2). 8

9

Outcome variables 10

Implant survival 11

Implant survival was assessed at the 3-year follow-up. The implant survival was 12

defined as the implant being in place and stable. The stability of the implant-supported 13

reconstruction and, if necessary, of the implant were assessed by mechanical testing with a 14

hand instrument. 15

16

Marginal bone level 17

Periapical radiographs were taken immediately after implant insertion, at 6 months, at 18

1 year and at 3 years. Standardized radiographs were taken by using individualized X-ray 19

film holder devices. The individualization of the film holder was performed with a bite-20

registration material (R-SI-LineⓇ Metal-BiteⓇ, R-dental GmbH, Hamburg, Germany). The film 21

was positioned parallel to the implant axis and the X-ray beam directed perpendicular to the 22

implant. The radiographs were digitized as jpeg files and imported in the ImageJ 1.43 open-23

source software (National Institute of Health, Bethesda, MD, USA). A calibrated investigator, 24

who was unaware of the treatment strategy and the aim of the study, evaluated all the 25

radiographic images. 26

The marginal bone level (MBL) was assessed on the mesial and on the distal aspect 27

of each implant by measuring the distance between the implant shoulder and first bone-to-28

Page 10: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

9

implant contact. The known distance between implant threads was used for the calibration of 1

the images. Mesial and distal MBL values were averaged to one value per implant. The 2

changes in MBL from implant placement to 6, 12 and 36 months examinations were 3

calculated. A negative change of MBL denoted a loss of marginal bone. 4

5

Clinical parameters 6

At the 1- and 3-year follow-up examinations, the following variables were assessed: 7

• Full-mouth plaque score (FMPS) at six sites per tooth/implant (O'Leary et al., 1972) 8

• Full-mouth bleeding on probing score (FMBS) at six sites per tooth/implant (Ainamo and 9

Bay, 1975) 10

• Plaque control record (PCR) at six sites per study implant (O'Leary et al., 1972) 11

• Bleeding on probing score (BOP) at six sites per study implant (Ainamo and Bay, 1975) 12

• Probing pocket depth (PPD) at six sites per study implant 13

• Width of the keratinized mucosa (KM) at the mid-buccal aspect of the study implant 14

15

Mid-facial mucosa and papilla levels 16

After the insertion of the final crown (6 months after implantation), at the 1- and 3-year 17

examinations, the levels of the mid-facial mucosa and of the inter-proximal papillae were 18

assessed. The tangent to the incisal edge/buccal cusp of the implant-supported crown was 19

used as the reference line. The measurements were performed with a periodontal probe and 20

the values approximated to the nearest 0.5 mm. 21

The changes in mucosa levels from 6 months to 1 and 3 years were calculated. A 22

negative value denoted a reduction in soft tissue level. 23

24

Adverse events and complications 25

The occurrence of adverse events (AE) and biological and technical complications 26

was recorded at each study visit. The following biological complications were assessed: 27

implant mobility, persistent subjective complaints, continuous peri-implant radiolucency, peri-28

Page 11: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

10

implant infection with suppuration (Buser et al., 1990). Peri-implantitis was defined as bone 1

loss > 2 mm in combination with a positive BOP recording (Sanz et al., 2012). The list of the 2

technical complications included: implant fracture, abutment fracture, fracture of the 3

veneering ceramic, loosening of the abutment screw, fracture of the abutment screw. If 4

needed, appropriate treatment was performed and the patient was monitored until the AE or 5

complication was resolved. 6

7

Statistical analysis 8

The statistical analysis was performed with SPSS Statistics 20.0 (SPSS Inc., 9

Chicago, IL, USA) and Stat X act 11.0 (Cytel, Cambridge, MA, USA). 10

The primary parameter was the change of MBL from the implant placement to the 3-11

year examination. The sample size calculation was based on two independent groups, a 12

normal distribution and the two-sample t-test. To detect a difference of 0.5 mm with a 13

standard deviation (SD) of 0.5 mm (power: 80%, significance level: 0.05), 17 patients per 14

group (total of 34 patients) were required. To compensate for possible drop-outs, the sample 15

size was increased to 20 patients per group (total of 40 patients). 16

For the statistical analysis the six values around each implant for PCR, BOP and PPD 17

and the two values for MBL and papilla level at the mesial and distal aspect were averaged 18

to one value each. For MBL and papilla level, the mesial, the distal and the mean values 19

were analyzed separately. For discrete variables, the absolute and the relative frequencies 20

were calculated. For continuous parameters, the data distributions were represented with 21

boxplots and the data were reported by using means, standard deviations (SD), ranges, 22

medians, and interquartile ranges (IQR). The non-parametric Mann–Whitney test was 23

applied to detect differences between the groups because of non-normality of the data. To 24

analyse the centre effect on the primary endpoint, the non-parametric Hodges-Lehmann 25

estimate together with the non-parametric 95% confidence intervals (CI) were used. For 26

implant survival, the 95% CI for the true survival was computed. Results of tests with p-27

Page 12: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

11

values ≤ 0.05 were considered statistically significant. No correction for multiple testing was 1

performed for the analyses of the secondary endpoints. 2

3

4

Results 5

Patients 6

A total number of 40 patients were included in this study from January 2010 to 7

December 2010. Of these, 20 were randomized to the Ti group and 20 to the Ti-Zr group. 8

There were no significant differences between the treatment groups with respect to the 9

following parameters: patient gender, patient age, smoking, implant location and time point of 10

implant placement after tooth extraction (p > 0.05) (Table S1). At 3 years, 32 out of the 40 11

included patients attended the follow-up examination, rendering a recall rate of 80%. Two 12

subjects had moved and were classified as lost to follow-up between 6 and 12 months. 13

Between 1 and 3 years, 6 patients had moved or passed away and could not be recruited for 14

the follow-up examination. 15

16

Implant survival 17

At the 1-year follow-up, 18 Ti and 20 Ti-Zr implants were evaluated. At 3 years, 15 out 18

of 20 Ti implants (75%) and 17 out of 20 Ti-Zr implants (85%) were examined. During the 19

entire study observation period, no implant failures were recorded, yielding a 3-year implant 20

survival rate of 100% for both the Ti (95% CI: 78%; 100%) and the Ti-Zr groups (95% CI: 21

80%; 100%). 22

23

Marginal bone level 24

From the implant placement to the 3-year follow-up, the median change of mean MBL 25

amounted to 0.21 mm (mean ± SD: -0.31 ± 0.59 mm in the Ti group and 0.10 mm (mean ± 26

Page 13: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

12

SD: -0.40 ± 0.93 mm) in the Ti-Zr group with no significant difference between the groups (p 1

= 0.720) (Table 1, Fig. 3). 2

The centre effect on the change in MBL from the implant placement to the 3-year 3

examination was not statistically significant (p = 0.058). When analysing the data for each 4

centre separately, the differences between the treatment groups were not statistically 5

significant (Boston: 95% CI: -0.09, 1.04 mm; Zurich: 95% CI: -0.51, 0.24 mm). 6

From the 1-year to the 3-year examination, the median change in mean MBL 7

measured -0.01 mm (mean ± SD: 0.14 ± 0.59 mm) for the Ti implants and -0.04 mm (mean ± 8

SD: -0.05 ± 0.41 mm) for the Ti-Zr implants. The difference between the groups was not 9

statistically significant (p = 0.692) (Table 1, Fig. 3). 10

When analysing the changes in the mesial and in the distal MBL separately, there 11

were no significant differences between the Ti and the Ti-Zr groups for the period from 12

implant placement to the 3-year examination (mesial: p = 0.880; distal: p = 0.637 distal) and 13

the period from 1 to 3 years (mesial: p = 0.417; distal: p = 0.777). 14

The frequency distributions of the changes in MBL from the implant placement to the 15

1-year examination were described in a previous publication (Benic et al., 2013). The 16

corresponding results from implant placement to the 3-year follow-up are represented in 17

Figure 4. One year after implant placement, there were two Ti-Zr implants with >2 mm of 18

bone loss at the mesial aspect and one Ti implant with >2 mm of bone loss at the distal 19

aspect. One of the two Ti-Zr implants could not be examined at 3 years because the patient 20

was lost to follow-up. At the 3-year examination, two Ti-Zr implants and no Ti implants were 21

observed with >2 mm of bone loss. 22

23

Clinical parameters 24

The results of FMPS, PCR, BOP and KM are presented in Table 2. At 3 years, there 25

were no statistically significant differences in FMPS, PCR, BOP and KM between the groups 26

(p > 0.05). The median FMBS amounted to 12 % (mean ± SD: 15.7 ± 11.6 %) for Ti implants 27

Page 14: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

13

and 4 % (mean ± SD: 6.9 ± 7.3 %) for Ti-Zr implants. The difference in FMBS between the 1

groups reached statistical significance (p = 0.028). 2

3

Mid-facial mucosa and papilla levels 4

The results of the changes in facial mucosa and papilla levels are presented in Table 5

3. From the 6-month to the 1-year examination, the median change in mid-facial mucosa 6

level measured 0 mm (mean ± SD: 0.2 ± 0.6 mm) for the Ti implants and 0 mm (0.0 ± 0.8 7

mm) for the Ti-Zr implants. The difference between the groups did not reach statistical 8

significance (p = 0.480). From the crown insertion (6 months after implantation) to the 3-year 9

follow-up, the median change of mid-facial mucosa level amounted to 0.5 mm (mean ± SD: -10

0.3 ± 1.1 mm) in the Ti group and -0.5 mm (mean ± SD: -0.3 ± 0.9 mm) in the Ti-Zr group 11

with no significant difference between the groups (p = 0.281) (Table 3). 12

In terms of change in mesial and distal papilla levels, there were no significant 13

differences between the groups (p > 0.05) (Table 3). 14

15

Adverse events and complications 16

Postoperative complications were described in a previous publication (Benic et al., 17

2013). 18

From 6 months to 3 years, there were no cases of implant mobility, persistent 19

subjective complaints, continuous peri-implant radiolucency, or peri-implant infection with 20

suppuration. At 3 years, one Ti-Zr implant was diagnosed with peri-implantitis (1/17 = 5.9%) 21

according to the specific definition (Sanz et al., 2012). Another Ti-Zr implant was affected by 22

peri-implantitis at the 1-year follow-up. This patient could not be recruited for the 3-year 23

examination. 24

At the 3-year follow-up, it bled on probing at totally 18 implants. Therefore, according 25

to the specific definition (Sanz et al., 2012) peri-implant mucositis was diagnosed at 10 Ti 26

implants and at 8 Ti-Zr implants. 27

Page 15: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

14

At the 3-year follow-up, two technical complications were recorded in the Ti-Zr group 1

(2/17 = 11.8%): one polishable fracture of the veneering ceramic and one loosening of the 2

abutment screw. At 3 years, one polishable chipping of the veneering ceramic was observed 3

in the Ti group (1/15 = 6.7%). 4

5

6

Discussion 7

The results of the present randomized controlled clinical study suggest that Ti-Zr 3.3 8

mm diameter and Ti 4.1 mm diameter two-piece implants do not differ with respect to the 9

change in marginal bone level from the implant placement to the 3-year examination. There 10

were no implant failures during the 3-year observation period. Furthermore, there were no 11

differences between the Ti-Zr narrow-diameter and the Ti regular-diameter implants 12

regarding the soft tissue parameters and the changes of the peri-implant mucosal level. 13

These results are in accordance with the data reported in previous clinical studies 14

investigating Ti-Zr 3.3 mm diameter implants. In a recent randomized controlled, double-15

blind, split-mouth trial, 3.3 mm-diameter two-piece Ti and Ti-Zr implants were compared 16

(Quirynen et al., 2014). All the patients received one Ti and one Ti-Zr implant in the 17

interforaminal region of the edentulous mandible. Implants were loaded after 6–8 weeks with 18

removable locator-retained over-dentures. Of the 91 treated patients, 75 completed the 3-19

year follow-up. One Ti-Zr and two Ti implants were lost, yielding a 3-year survival rate of 20

98.7% for Ti-Zr implants and 97.3% for Ti implants. With respect to the implant survival and 21

the change in MBL, there were no statistically significant differences between the groups. 22

The change of mean MBL between implant placement and 3 years reached -0.78 mm for Ti-23

Zr implants and -0.60 mm for Ti implants. In a pilot clinical study, 22 patients received Ti-Zr 24

one-piece 3.3 mm diameter implants for the support of fixed reconstructions in the anterior 25

and the premolar regions (Barter et al., 2012). The Ti-Zr narrow-diameter implants were 26

splinted either to regular- or to wide-diameter implants. At 2 years, the survival rate of the Ti-27

Page 16: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

15

Zr implants reached 95.2% and the mean change of MBL was -0.33 mm. Another clinical 1

study assessed the use of narrow-diameter one-piece Ti and Ti-Zr implants placed in the 2

posterior region of the jaw to support single crowns (Tolentino et al., 2014). In this 3

randomized controlled trial, 21 patients received a 3.3 mm-diameter Ti-Zr implant and 21 4

subjects were treated with a 3.3 mm-diameter Ti implant. During the first 6 weeks after 5

implant placement, one implant was lost in each group. At the 1-year examination, the 6

survival and the success rates amounted to 95.2 % for both groups (Tolentino et al., 2014). 7

In the present study, no implant fractures occurred. At 3 years, two technical 8

complications were observed in the test group, corresponding to a technical complication 9

rate of 11.8%. In a recent systematic review, the cumulative 5-year rate for technical 10

complication rate for single implant crowns reached 8.8% (Jung et al., 2012). Abutment- and 11

screw-loosening, loss of retention and fracture of the veneering material were the most 12

frequent technical complications (Jung et al., 2012). These data are in accordance with the 13

findings of the present clinical trial. 14

The main limitation of the present study is the fact that the treatment groups differed 15

regarding the implant material and the implant diameter. Therefore, no conclusions can be 16

drawn on implant diameter or implant material separately. Moreover, the difference in two 17

variables represents a potential confounder since both parameters may be associated with 18

the study outcome. In this context it has to be emphasized that several preclinical and clinical 19

trials found no differences between Ti-Zr and Ti implants with respect to osseointegration 20

and change in the marginal bone level (Thoma et al., 2011, Al-Nawas et al., 2012, Quirynen 21

et al., 2014, Gottlow et al., 2012, Saulacic et al., 2012, Anchieta et al., 2013, Wen et al., 22

2013). As far as the clinical relevance is concerned, the main question is whether narrow-23

diameter implants made of Ti-Zr represent a valid alternative to the Ti regular-diameter 24

implants, which are considered the gold standard for single tooth gaps in the anterior and the 25

premolar regions. The present study aimed to answer this question. Another limitation of the 26

present study is given by the fact that implants with and without GBR of peri-implant defects 27

were included. This variable represents a potential confounder of the primary outcome. 28

Page 17: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

16

Currently, there is a high level of evidence that implants placed simultaneously with GBR do 1

not differ from the implants placed into pristine bone with respect to the interproximal 2

marginal bone levels (Benic and Hammerle, 2014, Benic et al., 2009, Jung et al., 2013, 3

Mayfield et al., 1998, Zumstein et al., 2012). Moreover, in the current trial the treatment 4

groups did not differ regarding the distribution of cases with GBR. 5

The results of the present study are promising, since the use of narrow-diameter 6

implants has the potential to preserve the peri-implant tissue and, consequently, to reduce 7

the need for bone grafting procedures (Papadimitriou et al., 2014, Caneva et al., 2010). 8

However, more clinical long-term investigations are needed reporting survival and success 9

rates of narrow-diameter implants. When using implants with narrow diameter, it is therefore, 10

recommended to take into account the potential risk of biomechanical complications. 11

12

13 14 15 16

Conclusions 17

Within the limitation of the present randomized controlled trial it can be concluded that 18

the Ti-Zr 3.3 mm diameter implants do not differ from the Ti 4.1 mm diameter implants with 19

respect to the change in MBL from the implant placement to the 3-year examination. From 1 20

to 3 years, the implants under investigation exhibited stable MBL. During the 3-year 21

observation period there were no implant failures and no device-related serious adverse 22

events. Moreover, no differences regarding the soft tissue parameters and the changes in 23

the mucosa levels were found between the groups. 24

25

26

27

28

Page 18: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

17

Acknowledgements: The investigators gratefully acknowledge PhD Caroline Lustenberger 1

for the assistance in analysing the data. 2

3

Conflict of interest: Dres. Benic, Gallucci, Weber, Jung and Prof. Hämmerle provided 4

lectures or consultations, which were reimbursed from Institut Straumann AG. The authors 5

report no financial interests related to any products involved in this study. This study was 6

supported by an unrestricted grant from ITI Foundation, by the Clinic of Fixed and 7

Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, 8

University of Zurich, Switzerland, and by the Department of Restorative Dentistry and 9

Biomaterials Sciences, Harvard School of Dental Medicine. 10

Page 19: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

18

Tables and Figures 1

Tables 2

Table 1. (a) Results of the marginal bone level at the implant placement, at 6 months, at 1 3

year and at 3 years. (b) Results of the change in marginal bone level from the implant 4

placement to 1 year, from implant placement to 3 years and from 1 year to 3 years (negative 5

values represent bone loss). 6

7 8

9

10

11

12

13

14

15

16

17

18

Ti 4.1 Ti-Zr 3.3

n Mean ± SD Median IQR Range n Mean ± SD Median IQR Range p-value *

(a) Marginal bone level (mm)Implant placement Mesial 20 -0.07 ± 0.24 0 0 -1.00 to 0.00 20 -0.08 ± 0.15 0 0.10 -0.56 to 0 0.351

Distal -0.05 ± 0.18 0 0 -0.73 to 0.00 -0.11 ± 0.18 0 0.27 -0.54 to 0 0.390

Mean -0.06 ± 0.14 0 0 -0.50 to 0.00 -0.09 ± 0.12 0.05 0.18 -0.38 to 0 0.086

6 months Mesial 20 -0.27 ± 0.31 0.15 0.28 -1.28 to 0.00 20 -0.33 ± 0.30 0.22 0.53 -0.95 to 0.11 0.396

Distal -0.29 ± 0.42 0.21 0.50 -1.62 to 0.10 -0.40 ± 0.42 0.38 0.63 -1.21 to 0.20 0.184

Mean -0.28 ± 0.28 0.22 0.40 -1.11 to -0.01 -0.39 ± 0.33 0.36 0.45 -1.06 to 0.12 0.194

1 year Mesial 18 -0.41 ± 0.47 0.24 0.83 -1.28 to 0.23 20 -0.50 ± 0.75 0.24 0.42 -2.85 to 0.18 0.874

Distal -0.51 ± 0.68 0.31 0.69 -2.26 to 0.12 -0.51 ± 0.58 0.26 0.58 -1.78 to 0.03 0.942

Mean -0.46 ± 0.50 0.28 0.44 -1.73 to -0.09 -0.50 ± 0.63 0.30 0.40 -2.15 to 0.10 0.965

3 years Mesial 15 -0.28 ± 0.50 0.16 0.93 -1.23 to 0.34 17 -0.42 ± 0.70 0.19 0.56 -2.13 to 0.33 0.748

Distal -0.48 ± 0.68 0.27 0.84 -1.88 to 0.34 -0.59 ± 1.14 0.33 0.71 -4.07 to 0.30 0.910

Mean -0.38 ± 0.55 0.26 0.52 -1.55 to 0.34 -0.50 ± 0.90 0.27 0.48 -3.08 to 0.28 0.925

(b) Change of marginal bone level (mm)Implant placement - 1 year Mesial 18 -0.34 ± 0.47 -0.22 0.57 -1.28 to 0.23 20 -0.42 ± 0.77 -0.11 0.44 -2.75 to 0.42 0.696

Distal -0.46 ± 0.68 -0.26 0.53 -2.26 to 0.12 -0.40 ± 0.60 -0.17 0.57 -1.78 to 0.38 0.784

Mean -0.40 ± 0.53 -0.22 0.49 -1.73 to 0.14 -0.41 ± 0.66 -0.16 0.49 -2.10 to 0.17 0.696

Implant placement - 3 years Mesial 15 -0.21 ± 0.62 0.16 0.95 -1.23 to 1.20 17 -0.33 ± 0.78 0.15 0.70 -2.13 to 0.89 0.88

Distal -0.41 ± 0.65 0.26 0.43 -1.88 to 0.34 -0.48 ± 1.15 0.13 0.68 -4.07 to 0.51 0.637

Mean -0.31 ± 0.59 0.21 0.59 -1.55 to 0.67 -0.40 ± 0.93 0.10 0.60 -3.08 to 0.56 0.720

1 year - 3 years Mesial 15 0.17 ± 0.37 -0.08 0.60 -0.23 to 1.08 17 -0.01 ± 0.35 -0.04 0.33 -1.08 to 0.48 0.417

Distal -0.41 ± 0.65 -0.01 0.54 -1.88 to 1.94 -0.08 ± 0.65 -0.06 0.34 -2.29 to 0.41 0.777

Mean 0.14 ± 0.59 -0.01 0.60 -1.05 to1.25 -0.05 ± 0.41 -0.04 0.26 -1.12 to 0.43 0.692

* Results of Mann-Whithney test. Ti 4.1, titanium 4.1 mm diameter implants; Ti-Zr 3.3, titanium-zirconium 3.3 mm diameter implants; n, number; SD, standard deviation; IQR, interquartile range.

Page 20: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

19

Table 2. Results of the clinical parameters at 3 years 1

2 3

Table 3. Results of (a) change in the mesial papilla level, (b) change in the distal papilla level 4

and (c) change in the mid-facial mucosa level from 6 months to 3 years (negative values 5

represent mucosal recession) 6

7

8 9

Ti 4.1 ( n = 15) Ti-Zr 3.3 ( n = 17)

Mean ± SD Median IQR Range Mean ± SD Median IQR Range p-value *

FMPS (%) 27.3 ± 14.5 22 20 12 to 65 19.6 ± 12.0 15 17 5 to 49 0.061

FMBS (%) 15.7 ± 11.6 12 16 0 to 36 6.9 ± 7.3 4 9 0 to 24 0.028 ✝

PCR (%) 10.0 ± 16.4 0 9 0 to 50 7.7 ± 11.9 0 17 0 to 33 0.911

BoP (%) 20.0 ± 19.1 17 33 0 to 67 13.8 ± 17.9 0 25 0 to 50 0.298

PPD (mm) 2.9 ± 0.8 2.7 0.7 1.8 to 4.3 2.6 ± 0.8 3 1.3 1.2 to 3.7 0.732

KM (mm) 2.8 ± 1.1 3 2 0 to 4 3.2± 1.1 3 1.5 1 to 5 0.314

* Results of Mann-Whitney test. Ti 4.1, titanium 4.1 mm diameter implants; Ti-Zr 3.3, titanium-zirconium 3.3 mm diameter

implants; n, number; SD, standard deviation; IQR, interquartile range; FMPS, full-mouth plaque score; FMBS, full-mouth

bleeding score; PCR, plaque control record; BOP, bleeding on probing; PPD, probing pocket depth; KM, width of keratinized

mucosa. ✝ p ≤ 0.05

Ti 4.1 Ti-Zr 3.3

n Mean ± SD Median IQR Range n Mean ± SD Median IQR Range p-value *

(a) Change of the mesial papilla level 6 months to 1 year 18 0.8 ± 1.3 0.3 2.0 -1.0 to 3.0 19 0.5 ± 1.4 0.0 1.5 -2.5 to 3.5 0.558

6 months to 3 years 15 0.5 ± 1.4 1.0 2.0 -2.0 to 3.0 16 0.3 ± 1.6 1.6 2.8 -2.5 to 3.5 0.572

1 year to 3 years 15 -0.2 ± 1.4 0.0 1.0 -2.0 to 3.0 16 -0.3 ± 0.8 0.0 0.9 -2.0 to 1.0 0.892

(b) Change of the distal papilla level 6 months to 1 year 18 0.8 ± 1.0 0.8 1.3 -1.0 to 3.0 19 0.1 ± 1.5 0.0 2.0 -2.5 to 3.0 0.070

6 months to 3 years 15 -0.1 ± 1.4 1.0 2.0 -3.0 to 2.0 16 -0.5 ± 1.7 0.0 1.4 -4.0 to 3.0 0.682

1 year to 3 years 15 -0.8 ± 1.3 -0.5 2.0 -4.0 to 1.0 16 -0.4 ± 1.3 0.0 1.0 -4.0 to 2.0 0.401

(c) Change of the mid-facial mucosa level 6 months to 1 year 18 0.2 ± 0.6 0.0 0.6 -1.0 to 1.5 19 0.0 ± 0.8 0.0 1.0 -2.0 to 1.0 0.480

6 months to 3 years 15 -0.3 ± 1.1 0.5 0.0 -3.0 to 1.5 16 -0.3 ± 0.9 -0.5 1.4 -2.0 to 1.0 0.281

1 year to 3 years 15 -0.5 ± 0.8 0.0 1.0 -3.0 to 0.0 16 -0.2 ± 0.4 0.0 0.5 -1.0 to 0.5 0.572

* Results of Mann-Whitney test for the inter-group analysis. Ti 4.1, titanium 4.1 mm diameter implants; Ti-Zr 3.3, titanium-zirconium 3.3 mm diameter

implants; n, number; SD, standard deviation ; IQR, interquartile range.

Page 21: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

20

Table S1. Patient demographics, distribution of implant locations and time points of implant 1

placement after tooth extraction (Benic et al., 2013). 2

3 4 Table S2. Results of the intra-surgical parameters (Benic et al., 2013). 5

6

7

Ti 4.1 (n = 20) TiZr 3.3 (n = 20) P-value*

Gender, n (%) Male 11 (55) 11 (55) 0.999 Female 9 (45) 9 (45)Age (years) Mean ± SD 51.5 ± 14.1 54.2 ± 14.2 0.327 Range 21 to 80 25 to 75 95% CI 44.9; 58.1 47.5; 60.9 Median 51.0 61.5 IQR 16.5 17.0Smokers, n (%) No 17 (85) 17 (85) 0.999 Yes 3 (15) 3 (15)Site, n (%) Incisive 2 (10) 1 (5) 0.766 Canine 2 (10) 3 (15) Premolar 16 (80) 16 (80)Jaw, n (%) Maxilla 16 (80) 14 (70) 0.716 Mandible 4 (20) 6 (30)Implantation time-point, n (%) Type II 1 (5) 3 (15) 0.472 Type III 5 (25) 3 (15) Type IV 14 (70) 14 (70)Ti 4.1, titanium 4.1 mm-diameter implants; TiZr 3.3, titanium-zirconium 3.3 mm-diameter implants; n, number; *, results of Mann-Whitney and Chi2 tests; SD, standard deviation; 95% CI, 95% confidence interval; IQR, interquartile range

Table S1. Patient demographics, distribution of implant locations and time points of implant placement after tooth extraction

Ti 4.1 ( n = 20) Ti-Zr 3.3 ( n = 20) p-value *

Peri-implant bone defect n (%)

no 13 (65) 13 (65) 0.999

yes 7 (35) 7 (35)

Bone augmentation n (%)

no 11 (55) 10 (50) 0.999

yes 9 (45) 10 (50)

* Results of Mann-Whitney test. Ti 4.1, titanium 4.1 mm diameter implants; Ti-Zr 3.3, titanium-zirconium

3.3 mm diameter implants; n, number

�1

Page 22: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

21

1 2 Figures 3

Figure 1. Time sequence of interventions and examinations. 4

5 6

Day

0

3 m

onth

s

6 m

onth

s

1 ye

ar

Screening Pretreatment

Randomization Implantation

Suture removal

Re-entry surgery

1 w

eek

Insertion of the temporary

crown

Insertion of the definitive

crown

!Follow-up

examinations

2 w

eeks

6 w

eeks

Post-operative examinations

Reconstructive phase

Surgical phase

3 ye

ars

!Follow-up

examinations

Follow-up phase

Page 23: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

22

Figure 2. (a) Intra-operative situation of site 13 after the placement of a titanium-zirconium 1

implant with 3.3 mm diameter. (b) Occlusal view after the soft tissue healing. (c) Occlusal 2

view and (d) facial view after the insertion of the definitive porcelain-fused-to-metal crown. (e) 3

Occlusal view, (f) facial view and (g) periapical radiograph at the 3-year follow-up. 4

5 6

(a) (b)

(c) (d)

(e) (f) (g)

Page 24: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

23

Fig. 3. Box plots representing the mean marginal bone levels (in mm) relative to the implant 1

shoulder at the implant placement, at 6 months, at 1 year and at 3 years (a) in the titanium 2

4.1 mm diameter (Ti 4.1) and (b) in the titanium-zirconium 3.3 mm diameter (Ti-Zr 3.3) 3

groups. Box plots depicting the change of mean marginal bone level (in mm) from the implant 4

placement to 3 years and from 1 year to 3 years (c) in the Ti 4.1 and (d) in the Ti-Zr 3.3 5

groups. ° and * in the figure represent the outliers. 6

7 8

(c) (d)

Ti 4.1 mm

(a)

Ti-Zr 3.3 mm

(b)

Page 25: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

24

Figure 4. Frequency distributions of the changes in (a) mesial, (b) distal and (c) mean 1

marginal bone level (in mm) from the implant placement to the 3-year examination. 2

3

4

0

10

20

30

40

50

60

>-2 -2 to -1.5 -1.5 to -1 -1 to -0.5 -0.5 to 0 0 to 0.5

Pat

ient

s (%

)

Change'in'mesial'marginal'bone'level'from'implant placement to 3years (in mm)

Ti TiZr

0

10

20

30

40

50

60

>-2 -2 to -1.5 -1.5 to -1 -1 to -0.5 -0.5 to 0 0 to 0.5

Pat

ient

s (%

)

Change in distal marginal bone level from implant placement to 3years (in mm)

Ti TiZr

0

10

20

30

40

50

60

>-2 -2 to -1.5 -1.5 to -1 -1 to -0.5 -0.5 to 0 0 to 0.5

Pat

ient

s (%

)

Change in mean marginal bone level from implant placement to 3years (in mm)

Ti TiZr

Pat

ient

s (%

)P

atie

nts

(%)

Pat

ient

s (%

)

Change in mean marginal bone level from implant placement to 3 years

(a)

Change in mesial marginal bone level from implant placement to 3 years

(b)

Change in distal marginal bone level from implant placement to 3 years

(c)

Page 26: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

25

References 1

Ainamo, J. & Bay, I. (1975) Problems and proposals for recording gingivitis and 2 plaque. International Dental Journal 25, 229-235. 3

Al-Nawas, B., Bragger, U., Meijer, H. J., Naert, I., Persson, R., Perucchi, A., 4 Quirynen, M., Raghoebar, G. M., Reichert, T. E., Romeo, E., Santing, H. 5 J., Schimmel, M., Storelli, S., ten Bruggenkate, C., Vandekerckhove, B., 6 Wagner, W., Wismeijer, D. & Muller, F. (2012) A double-blind 7 randomized controlled trial (RCT) of Titanium-13Zirconium versus 8 Titanium Grade IV small-diameter bone level implants in edentulous 9 mandibles--results from a 1-year observation period. Clinical Implant 10 Dentistry and Related Research 14, 896-904. doi:10.1111/j.1708-11 8208.2010.00324.x. 12

Anchieta, R. B., Baldassarri, M., Guastaldi, F., Tovar, N., Janal, M. N., Gottlow, 13 J., Dard, M., Jimbo, R. & Coelho, P. G. (2013) Mechanical Property 14 Assessment of Bone Healing around a Titanium-Zirconium Alloy Dental 15 Implant. Clinical Implant Dentistry and Related Research. 16 doi:10.1111/cid.12061. 17

Barter, S., Stone, P. & Bragger, U. (2012) A pilot study to evaluate the success 18 and survival rate of titanium-zirconium implants in partially edentulous 19 patients: results after 24 months of follow-up. Clinical Oral Implants 20 Research 23, 873-881. doi:10.1111/j.1600-0501.2011.02231.x. 21

Benic, G. I., Gallucci, G. O., Mokti, M., Hammerle, C. H., Weber, H. P. & Jung, 22 R. E. (2013) Titanium-zirconium narrow-diameter versus titanium 23 regular-diameter implants for anterior and premolar single crowns: 1-year 24 results of a randomized controlled clinical study. Journal of Clinical 25 Periodontology 40, 1052-1061. doi:10.1111/jcpe.12156. 26

Benic, G. I. & Hammerle, C. H. (2014) Horizontal bone augmentation by means 27 of guided bone regeneration. Periodontology 2000 66, 13-40. 28 doi:10.1111/prd.12039. 29

Benic, G. I., Jung, R. E., Siegenthaler, D. W. & Hammerle, C. H. (2009) 30 Clinical and radiographic comparison of implants in regenerated or native 31 bone: 5-year results. Clinical Oral Implants Research 20, 507-513. 32 doi:10.1111/j.1600-0501.2008.01583.x. 33

Berner, S., Dard, M., Gottlow, J., Molenberg, A. & Wieland, M. (2009) 34 Titanium-Zirconium: A Novel Material for Dental Implants. European 35 Cells and Materials 17, 16. 36

Buser, D., Weber, H. P. & Lang, N. P. (1990) Tissue integration of non-37 submerged implants. 1-year results of a prospective study with 100 ITI 38 hollow-cylinder and hollow-screw implants. Clinical Oral Implants 39 Research 1, 33-40. 40

Caneva, M., Salata, L. A., de Souza, S. S., Baffone, G., Lang, N. P. & Botticelli, 41 D. (2010) Influence of implant positioning in extraction sockets on 42

Page 27: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

26

osseointegration: histomorphometric analyses in dogs. Clinical Oral 1 Implants Research 21, 43-49. doi:10.1111/j.1600-0501.2009.01842.x. 2

Chiapasco, M., Casentini, P., Zaniboni, M., Corsi, E. & Anello, T. (2012) 3 Titanium-zirconium alloy narrow-diameter implants (Straumann 4 Roxolid((R))) for the rehabilitation of horizontally deficient edentulous 5 ridges: prospective study on 18 consecutive patients. Clinical Oral 6 Implants Research 23, 1136-1141. doi:10.1111/j.1600-7 0501.2011.02296.x. 8

Davarpanah, M., Martinez, H., Tecucianu, J. F., Celletti, R. & Lazzara, R. 9 (2000) Small-diameter implants: indications and contraindications. 10 Journal of Esthetic Dentistry 12, 186-194. 11

Esposito, M., Ekestubbe, A. & Grondahl, K. (1993) Radiological evaluation of 12 marginal bone loss at tooth surfaces facing single Branemark implants. 13 Clinical Oral Implants Research 4, 151-157. 14

Gottlow, J., Dard, M., Kjellson, F., Obrecht, M. & Sennerby, L. (2012) 15 Evaluation of a new titanium-zirconium dental implant: a biomechanical 16 and histological comparative study in the mini pig. Clinical Implant 17 Dentistry and Related Research 14, 538-545. doi:10.1111/j.1708-18 8208.2010.00289.x. 19

Grandin, H. M., Berner, S. & Dard, M. (2012) A review of titanium zirconium 20 (TiZr) alloys for use in endosseous dental implants. Materials 5, 1348-21 1360. 22

Hammerle, C. H., Chen, S. T. & Wilson, T. G., Jr. (2004) Consensus statements 23 and recommended clinical procedures regarding the placement of 24 implants in extraction sockets. International Journal of Oral and 25 Maxillofacial Implants 19 Suppl, 26-28. 26

Hammerle, C. H., Jung, R. E. & Feloutzis, A. (2002) A systematic review of the 27 survival of implants in bone sites augmented with barrier membranes 28 (guided bone regeneration) in partially edentulous patients. Journal of 29 Clinical Periodontology 29 Suppl 3, 226-231; discussion 232-223. 30

Jung, R. E., Fenner, N., Hammerle, C. H. & Zitzmann, N. U. (2013) Long-term 31 outcome of implants placed with guided bone regeneration (GBR) using 32 resorbable and non-resorbable membranes after 12-14 years. Clinical 33 Oral Implants Research 24, 1065-1073. doi:10.1111/j.1600-34 0501.2012.02522.x. 35

Jung, R. E., Zembic, A., Pjetursson, B. E., Zwahlen, M. & Thoma, D. S. (2012) 36 Systematic review of the survival rate and the incidence of biological, 37 technical, and aesthetic complications of single crowns on implants 38 reported in longitudinal studies with a mean follow-up of 5 years. Clinical 39 Oral Implants Research 23 Suppl 6, 2-21. doi:10.1111/j.1600-40 0501.2012.02547.x. 41

Klein, M. O., Schiegnitz, E. & Al-Nawas, B. (2014) Systematic review on 42 success of narrow-diameter dental implants. International Journal of Oral 43

Page 28: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

27

and Maxillofacial Implants 29 Suppl, 43-54. 1 doi:10.11607/jomi.2014suppl.g1.3. 2

Kobayashi, E., Matsumoto, S., Doi, H., Yoneyama, T. & Hamanaka, H. (1995) 3 Mechanical properties of the binary titanium-zirconium alloys and their 4 potential for biomedical materials. Journal of Biomedical Materials 5 Research 29, 943-950. doi:10.1002/jbm.820290805. 6

Mayfield, L., Skoglund, A., Nobreus, N. & Attstrom, R. (1998) Clinical and 7 radiographic evaluation, following delivery of fixed reconstructions, at 8 GBR treated titanium fixtures. Clinical Oral Implants Research 9, 292-9 302. 10

Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gotzsche, P. C., 11 Devereaux, P. J., Elbourne, D., Egger, M. & Altman, D. G. (2010) 12 CONSORT 2010 Explanation and Elaboration: Updated guidelines for 13 reporting parallel group randomised trials. Journal of Clinical 14 Epidemiology 63, e1-37. doi:10.1016/j.jclinepi.2010.03.004. 15

O'Leary, T. J., Drake, R. B. & Naylor, J. E. (1972) The plaque control record. 16 Journal of Periodontology 43, 38. doi:10.1902/jop.1972.43.1.38. 17

Papadimitriou, D. E., Friedland, B., Gannam, C., Salari, S. & Gallucci, G. O. 18 (2014) Narrow-Diameter versus Standard-Diameter Implants and Their 19 Effect on the Need for Guided Bone Regeneration: A Virtual Three-20 Dimensional Study. Clinical Implant Dentistry and Related Research. 21 doi:10.1111/cid.12224. 22

Quirynen, M., Al-Nawas, B., Meijer, H. J., Razavi, A., Reichert, T. E., 23 Schimmel, M., Storelli, S., Romeo, E. & the Roxolid Study, G. (2014) 24 Small-diameter titanium Grade IV and titanium-zirconium implants in 25 edentulous mandibles: three-year results from a double-blind, randomized 26 controlled trial. Clinical Oral Implants Research. doi:10.1111/clr.12367. 27

Sanz, M., Chapple, I. L. & Working Group 4 of the, V. E. W. o. P. (2012) 28 Clinical research on peri-implant diseases: consensus report of Working 29 Group 4. Journal of Clinical Periodontology 39 Suppl 12, 202-206. 30 doi:10.1111/j.1600-051X.2011.01837.x. 31

Saulacic, N., Bosshardt, D. D., Bornstein, M. M., Berner, S. & Buser, D. (2012) 32 Bone apposition to a titanium-zirconium alloy implant, as compared to 33 two other titanium-containing implants. Eur Cell Mater 23, 273-286; 34 discussion 286-278. 35

Tarnow, D. P., Cho, S. C. & Wallace, S. S. (2000) The effect of inter-implant 36 distance on the height of inter-implant bone crest. Journal of 37 Periodontology 71, 546-549. doi:10.1902/jop.2000.71.4.546. 38

Thoma, D. S., Jones, A. A., Dard, M., Grize, L., Obrecht, M. & Cochran, D. L. 39 (2011) Tissue integration of a new titanium-zirconium dental implant: a 40 comparative histologic and radiographic study in the canine. Journal of 41 Periodontology 82, 1453-1461. doi:10.1902/jop.2010.100737. 42

Tolentino, L., Sukekava, F., Seabra, M., Lima, L. A., Garcez-Filho, J. & Araujo, 43 M. G. (2014) Success and survival rates of narrow diameter implants 44

Page 29: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

28

made of titanium-zirconium alloy in the posterior region of the jaws - 1 results from a 1-year follow-up. Clinical Oral Implants Research 25, 137-2 141. doi:10.1111/clr.12113. 3

Wen, B., Zhu, F., Li, Z., Zhang, P., Lin, X. & Dard, M. (2013) The 4 osseointegration behavior of titanium-zirconium implants in 5 ovariectomized rabbits. Clinical Oral Implants Research. 6 doi:10.1111/clr.12141. 7

Zinsli, B., Sagesser, T., Mericske, E. & Mericske-Stern, R. (2004) Clinical 8 evaluation of small-diameter ITI implants: a prospective study. 9 International Journal of Oral and Maxillofacial Implants 19, 92-99. 10

Zumstein, T., Billstrom, C. & Sennerby, L. (2012) A 4- to 5-year retrospective 11 clinical and radiographic study of Neoss implants placed with or without 12 GBR procedures. Clinical Implant Dentistry and Related Research 14, 13 480-490. doi:10.1111/j.1708-8208.2010.00286.x. 14

15

16

Page 30: Zurich Open Repository and Year: 2015 narro… · 2 1 Abstract 2 Aim: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently 3 from titanium (Ti)

29

Clinical Relevance 1

Scientific rationale for the study: Narrow-diameter implants were introduced to overcome 2

clinical situations with reduced bone width bucco-orally or a narrow mesio-distal tooth-gap. 3

The strength of narrow-diameter titanium implants however is limited and thus implant 4

fractures may occur. By alloying titanium to other metals like zirconium (titanium-zirconium), 5

the strength of narrow-diameter implants can be improved. 6

Principal findings: Narrow-diameter (3.3 mm) titanium-zirconium implants did not perform 7

differently from regular-diameter (4.1 mm) titanium implants regarding the change in marginal 8

bone level from the implant placement to the 3-year examination. During this observation 9

period there were no implant failures. Furthermore, there were no significant differences 10

between the groups with respect to clinical parameters and occurrences of adverse events. 11

Practical implications: The use of titanium-zirconium narrow-diameter implants for the 12

support of single crowns in the anterior and premolar regions leads to successful tissue 13

integration and clinical performance over a 3-year period. Longer observation periods are 14

required to recommend the use of titanium-zirconium implants with narrow diameter for this 15

clinical indication. 16