ZICO RETRaCTablE V STEP M VS-24-11 VS-24-9 In M U M · ZICO® 3094PM9 QUIC-STEP™ RETRaCTablE...
Transcript of ZICO RETRaCTablE V STEP M VS-24-11 VS-24-9 In M U M · ZICO® 3094PM9 QUIC-STEP™ RETRaCTablE...
ZICO®
3094PM9QUIC-STEP™ RETRaCTablE VEhIClE STEP
ModEl VS-24-11 and VS-24-9InPoWER ConTRol ModUlE UPgRadE ManUal
Note: This manual provides instruction when upgrading a vehicle step from a "terminal post"-style InPOWER Control Module (PN 3094-005-195) to a "plug-in"-style InPOWER Control Module (PN 3094-030-137).
The following step manuals may ease the upgrade process or be beneficial for future reference, but are not required:
Old InPOWER Module: 3094PM1i (Model VS-24-11) & 3094PM4i (Model VS-24-9) New InPOWER Module: 3094PM1ii (Model VS-24-11) & 3094PM4ii (Model VS-24-9)
Manuals are available for download at ziamatic.com.
I. Part Information:
ITEM PART # DESCRIPTION QTY58 3094-030-137 InPOWER CONTROL MODULE 163 3094-005-198 TERMINAL, FEMALE, MOLEX 33012-3001 764 3094-030-139 WIRE HARNESS 1
II. General Information:
• Whenthevehicledoorisopenedandclosed,powerwillflowtoPins1(MOT1)&5(MOT2)for 4secondsorthepowerwillstopiftheampdemandexceeds12ampsfor100ms.Thepolaritywill alsoswitchfromanominal+12vdctoanominal-12vdcasthedoorisclosedandopened.
• IftestingtheInPOWERunitforvoltageacrossthePins1(MOT1)&5(MOT2),disconnectthe LinearActuatorandconnecta12vtestlightacrossthePins1&5tocauseacurrentflow(amp draw).(Theunitwillnotoperatewithoutacurrentflow(ampdraw).)Connectavoltmeteracross thoseterminalsandeitheropenandclosethevehicledoororplaceaswitchbetweenPin2(Bat(+)) andPin4(INP1).Thelightshouldgoonmomentary(4seconds)asthevoltageregistersanominal 12v.See"ChartofNCSwitch"forthepolarityofthepins.
Whenthevehicledoorisopenedandclosed,powerwillflowtoPins1(MOT1)&5(MOT2)for4 secondsorthepowerwillstopiftheampdemandexceeds12ampsfor100ms.Thepolaritywillalso switchfromanominal+12vdctoanominal-12vdcasthedoorisclosedandopened.
REV.1-13-17
II. Recommended Tools:
Note: The wire harness plug (Item 64) comes with factory installed wires. If hooking the vehicle's wiring di-rectly to the plug is preferred, the following tools are recommended:
ToolforFemaleTerminals(Item63):
• Molex63811-5900CrimpTool,16-14GAFemaleTerminalsMX150Series
ToolforWiringHarnessPlug(Item64)
• Molex63813-1500ExtractionTool,MX150Series
III. Preparing to Wire the New Unit
1. OnthewiresconnectingtheoldInPOWERmoduletothevehicle(seeFigure1):
- Labelthewiresas(BAT+),(GND),(M2),and(M1) - Labelthewiregoingfromthe"BAT+"tothevehicledooras(DoorBAT+) - Labelthewiregoingfromthe"SpadeTerminal"tothedooras(DoorSpade)
2. DisconnectthewiresfromtheoldInPOWERunit
IV. Wiring the New Unit
A. Option1:AttachingtheFemaleTerminals(Item63)DirectlytotheWiresfromVehicle
1. UsetheMolex63813-1500ExtractionTooltoremovethefemaleterminalsfromnewwire harnessplug 2. AttachFemaleTerminals(Item63)totheendofthewiresthatwerelabeledinSection3.1in accordancewithChart1(below) 3. PlugthewiresintothenewpluginaccordancewithChart1(below)(forreference,see Figures3&4) 4. Testtheunitforproperoperation.Ifthestepisoperatingintheoppositemanner,switchthe wiresgoingtoPins1and5
WiresLabeledinSection3.1 NewInPOWERHarnesslugwithwiresremoved(M1) PIN 1 (MOT1)(BAT+)and(DoorBAT+) PIN2(BAT)(DoorSpade) PIN 4 (INP 1)(M2) PIN 5 (MOT 2)(GND) PIN6(GND)
Chart1
B. Option2:SplicingtheWiresfromVehicleandExistingWiresonNewWiringHarness
1. TemporarilyconnectthewiresinaccordancewithChart2(below)(Forreference,see Figures3&4) 2. Testtheunitforproperoperation.Ifthestepisoperatingintheoppositemanner,switchthe wiresgoingtoPins1and5.
Important:Itishighlyrecommendedthatthewiresaresolderedtogetherandthatshieldingonthe wiresplicesisheatsealabletopreventthewiresfromdisconnecting
3. Permanentlysplicethewirestogetherandtestforproperoperation
Wiresthatwerelabeledinstep1 NewInPOWERWiringHarness(M1) PIN 1 (MOT1) (WHITE WIRE)(BAT+)and(DoorBAT+) PIN2(BAT)(REDWIRE)(DoorSpade) PIN4(INP1)(BLUEWIRE)(M2) PIN5(MOT2)(ORANGEWIRE)(GND) PIN6(GND)(BLACKWIRE)
Chart2
Note:Asthestepmovestothefullyopenorfullyclosedposition,theactuatormaymakearatchetsoundforabriefmomentattheendoftheeithercycle.Thisisasafetyfeatureoftheactuator.
Figure 1Existing Wiring Setup
FIGURE 2 - InPOWER Control Module with Wire Harness
Open Closed Pin 1 (-) Pin5(+) Extends GoesDownClosed Open Pin1(+) Pin 5 (-) Retracts GoesUp
DoorPosition Switch Polarity Actuator
Position Step
CHART FOR NC SWITCH
NOTE: REVERSE ACTUATOR MOTOR POLARITY ON INPOWER MODULE(PIN1&PIN5)IFDOORSWITCHISAN.O.SWITCH
CONTROLLOGIC
FIGURE 3 - ControlModule Pin Layout
FIGURE 4 - FIELD WIRING DIAGRAM MODE OF OPERATION• providepowertoautostep
EXTEND MODE:• stepwillautomaticallyextendas soonasthedoorisopened.• stepwillremainextendedaslong asdoorremainsopen.
RETRACTED MODE:• stepwillautomaticallyretractas soonasthedoorisclosed.• stepwillremainretractedaslong asdoorremainsclosed.
Note: Switch and electrical panel should be mounted in waterproof compartments. Once all electrical connections are complete and system has been tested, protect connections with a weather proofer like liquid tape.
Ziamatic Corp.10 West College Avenue, P.O. Box 337, Yardley, PA 19067-0587 • (215) 493-3618 • FAX: (215) 493-1401
*ZICO is a registered trademark for fire, safety and marine products made by Ziamatic Corp. Copyright Ziamatic Corp. 01-17