Presentation Outline
• Product Line up
• Membrane Fundamentals
• Strike Zone/Key Applications
• How do We Win?
• Competitive Landscape
• Case Studies
• Contact Information
![Page 3: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/3.jpg)
Product Line-up – IND WW
• ZeeWeed® Immersed Ultrafiltration
• MBR
• Tertiary Treatment
• Reverse Osmosis
• Ancillary Equipment, (Sludge Dewatering, Process Tanks etc.)
• Mobile Water Treatment Systems
![Page 4: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/4.jpg)
Membrane Fundamentals
![Page 5: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/5.jpg)
ZeeWeed® – The Membrane
• Immersed
• Hollow fiber
• Outside-in
• Ultrafiltration (UF)
• PVDF chemistry (chlorine and oxidant-resistant)
![Page 6: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/6.jpg)
ZeeWeed® Immersed Hollow Fibre UF
Membranes can be immersed in any tank, and clean water is produced.
![Page 7: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/7.jpg)
Membranes for Water Treatment
Conventional Pretreatment
![Page 8: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/8.jpg)
Electron microscope view of membrane surface
How Membranes Work
• Membrane fibers have billions of microscopic pores on the surface
• The pores form a barrier to impurities, while allowing pure water molecules to pass
• Water is drawn through the pores using a gentle suction
ZeeWeed® Membrane Fibers
![Page 9: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/9.jpg)
ZeeWeed® Immersed Outside-In Membrane
-2 to -5 psisuction pressure
Filtered Water
Liquid & Solids Liquid & Solids in free volumein free volume
of Process Tankof Process Tank
Solids, bacteria, cysts stay in process tank
![Page 10: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/10.jpg)
ZeeWeed® 500 – Reinforced Fibres• Inner reinforcing structure covered with a
composite polymer outer layer
• Pore Size:
– 0.04 micron (average)
– 0.1 micron (maximum)
• Strong: Single fiber can hold over 50 kg
• Robust: Can operate with < 1.0 mg/L TSS (DW) to 50,000+ mg/L MLSS (sludge thickening)
• Durable: Majority of modules installed are still in service (first ZeeWeed® membrane installed in 1993)
15 lbbowling ball
![Page 11: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/11.jpg)
Principles of Operation of Immersed Membranes
Feed
Permeate
Air injection
Immersed membranes
Purge
QF
QP
Qf
Membrane tank
Qbp YQ Q
QF P
F
Recovery
![Page 12: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/12.jpg)
Outside In Inside Out
vs.
Hollow Fibre Permeate Flow Path
ZeeWeed® Other
ZeeWeed®
Hollow Fibrefree flowing path
![Page 13: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/13.jpg)
ZeeWeed® Membrane
Inner reinforcing structurecovered with a composite
polymer outer layer
Immersible, Ultra Low Pressure, Oxidant Resistant, High Strength
Operates at -2 psi to -5 psi whenfiltering and 3 psi on backwash
Diameter Outer = 1.9 mmInner = 0.9 mm
Filtered Water
Process Tank(Influent)
X-Section
![Page 14: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/14.jpg)
ZeeWeed® Backwash
ZeeWeed® Base Diffuser
Clean-In-PlaceTank(Filtrate from membrane)
Process Tank Water
Backwash Cleaning(Reverse Flow with Filtrate)
ZeeWeed® uses clean filtrate to backwash itself. A reverse flow from the CIPtank is fed to the inside of the membrane fibers cleaning from the inside out
Cleaning chemicals are optional and not always necessary.
X-section
![Page 15: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/15.jpg)
ZeeWeed® Cleaning Shear
Upward component of cleaning shear at face of ZeeWeed due
to rising stream of air and solids from ZeeWeed® base
Sideways component of cleaning shear at face of ZeeWeed® due
to oscillation of membrane within airlift stream
Outside Face of ZeeWeed is kept free of solids build-up by the action of a rising solids/air/liquid stream around the face of the membrane fibers. This rising stream produces a Cleaning Shear at the face of the
membrane due to Membrane Oscillation and airlift effect of the rising stream.
ZeeWeed® Base Diffuser
ZeeWeed®
MembraneElement
![Page 16: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/16.jpg)
ZeeWeed® Membrane Cassettes
Permeate Header
Permeate Pump
Air Header
Air SeparatorMain Permeate
Header
ZeeWeed® 500 – the System
![Page 17: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/17.jpg)
Benefits of Immersed ZeeWeed® Technology
“Outside-in” permeation means that fibres don’t get plugged
Low energy requirements (80% less than Tubular)
Suitable/cost effective for high flow rates Membrane can be immersed directly in tank
(minimizes footprint requirement, making it easy to retrofit)
High packing density design Very strong fibre design (no worries of breakage) Membrane can be cleaned “in-situ”
![Page 18: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/18.jpg)
ZENON Packaged Wastewater Plants
![Page 19: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/19.jpg)
Temporary Treatment
![Page 20: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/20.jpg)
ZENONMembrane Bioreactor (MBR)
Filtrate(Treated WW)
Concentrate Return
10,000 to 15,000 mg/l
Feed
Bioreactor Membrane(Liquid/Solids Separator)
Sludge for Disposal
Hi-Rate Bioreactor
large capacity throughput
compact footprint
advanced treatment
simpler more reliable process (de-emphasizes biological component)
Absolute/Positive Filter
high degree of organisms/solids control
consistent effluent quality
lower operator attention - less components
![Page 21: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/21.jpg)
Mixed Liquor vs. ZeeWeed® Permeate
![Page 22: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/22.jpg)
Key Applications/Strike Zone - WW• Food and Beverage
• Pharmaceutical
• Petrochemical
• Chemical
• Automotive
• Oil and Gas
![Page 23: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/23.jpg)
ZENON Positioning
• Plant retrofits/upgrades lend themselves well to MBR – Easy to do
• Extensive widespread Industrial experience by ZENON – Lots of quality sites to visit
• < 2 year payback on Capital Investment – It is important for the customer to fully understand how
much they are spending for their current method of disposal
• Minimal operator attention required – Most Industrial facilities don't have dedicated wastewater
operators, so MBR plants run unmanned most of the time
![Page 24: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/24.jpg)
How We Win• Low price or Life Cycle Cost doesn't always win
– Clients are willing to pay for value added while minimizing fear, uncertainty and doubt about future sewer use requirements and by-laws
• Consulting Engineers are less involved in the process– Industry gurus are key and direct selling is preferred
• Successful pilot testing increases the probability of winning the job significantly – We win 90+% of the jobs that we pilot
• Clients that are truly interested in our technology don't mind paying for pilots– We very seldom give them away for free. Payment for pilot
testing is a very good project qualifier
![Page 25: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/25.jpg)
How We Win• Clients typically want one-stop-shopping and single
point liability – ZENON typically provides all of the MBR equipment
package (Equalization, Aeration Tanks, Membranes, Controls, MCC etc.) and takes full process responsibility
• Most Industrial projects are Design/Build or Turnkey, but can also do Supply Only and DBOOM
• Most of our clients have done business with us several times – Industrial customers are very loyal and thus we use a
repeat business model (if something isn't broken then they don't want to fix it)
![Page 26: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/26.jpg)
Design/Build Experience• Canadian Natural Resources Ltd. (Alberta) • Basic American Foods (Oregon)• Southern Company Plant McIntosh (Alabama)• Southern Company Plant Harris (Alabama)• ATCO Battle River Generating Station (Alberta)• TransAlta Wabamum Generating Station (Alberta)• Field (British Columbia) Sewage Treatment • Unifine Richardson (Ontario)• Brescia WWTP (Italy)• General Motors (Ontario)• Ford Motor Company (Mexico)• Violet Reinforcements (Mexico)• Zobelsreuth Drinking Water Plant (Germany)
![Page 27: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/27.jpg)
Competitive Landscape
![Page 28: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/28.jpg)
Membranes vs. Conventional Technology
Conventional Treatment•Mature19th century technology •Large land requirement•Coarse filtration, no physical barrier•Need multiple steps for coarse filtration•Labor and chemical intensive•Dependent on chlorine for disinfection
Membrane Treatment•Modern, continuously improving
technology •Compact footprint; Allows for expansion •Physical barrier means reliable filtration•Single step provides superior filtration•Fully automated with minimal chemicals•Disinfects by physical removal of
micro-organisms
![Page 29: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/29.jpg)
Wastewater
• Trickling Filters
• Oxidation Ditch eg. Eimco Carrousel
• Rotating Batch Contactors (RBC)
• Sequencing Batch Reactors (SBRs)
• Anaerobic Treatment
• Fixed Film Technologies
• Biologically Aerated Filter (BAF)
Where do membranes fit?
• High quality permeate required (regulation, or reuse etc.)
• Small plant footprint - no room for expansion
Conventional Technologies
Oxidation Ditch
RBC
![Page 30: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/30.jpg)
Hollow Fiber
MBR Membrane Competition
USFilter Memjet
Kubota
Koch / PuronMitsubishi
Flat Plate
Dynatec / NORIT
Tubular
Koch
Asahi
![Page 31: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/31.jpg)
How to Beat Kubota• Flat plate chlorinated PE MF (0.4 μm)
How to beat Kubota
• ZENON has a much better product
• No biolayer required to operate
• Easier to clean
• Lower O&M
• Smaller footprint
• ZENON has unparalleled MBR experience
• largest operating industrial MBRs
• Significant experience with difficult-to-treat wastewaters
• Most experienced support for industrial WW projects
![Page 32: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/32.jpg)
USFilter Memjet• O/I HF UF PVDF (0.05μm)
How to Beat USFilter Memjet
• Reinforced vs. unsupported fiber
• Defined spatial distribution vs. randomly potted fibers
• Aggressive, high energy jet aeration leads to fiber breakage, added complexity
• Experience:
• Limited to no industrial WW experience
• Earliest plant ~ 2002 vs. 1993 for ZENON
• High fiber breakage in pilot studies & full-scale municipal installations
![Page 33: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/33.jpg)
MRC Sterapore
• O/I horizontal hollow fiber, PE chemistry
• MF (0.4μm pores) vs. ZENON UF (0.035μm)
How to Beat Sterapore
• Reinforced vs. unsupported fiber
• Stretched MF pores vs. rounded UF pores (deep pore fouling, long-term pore integrity?)
• Experience:
• Limited industrial US WW experience
• Earliest US plant ~ 2000 vs. 1993 for ZENON
• Most plants performing poorly
![Page 34: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/34.jpg)
Tertiary Membrane Competition
Koch
USFilter CMFPall MicrozaNORIT USFilter CMF-S
Hydranautics HydraCAP
![Page 35: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/35.jpg)
Case Studies
• MBR
• Tertiary Treatment
• Re-use
![Page 36: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/36.jpg)
Basic American Foods, Blackfoot, Idaho• Key Project Design
Issues:– Design Flow Rate -1.5
MGD– Treating wastewater from
potato processing– Nitrification/Denitrification
for direct discharge– Complete Design/Build
project– Commissioned in March
2003
![Page 37: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/37.jpg)
Basic American Foods, Blackfoot, IDErection of Bioreactor Tank
![Page 38: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/38.jpg)
Basic American Foods, Blackfoot, IDInstallation of ZeeWeed® Tank
![Page 39: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/39.jpg)
Richardson Foods, St. Mary’s, Ontario• Turn-key project by ZENON• 40,000 USgpd• Highly variable waste
depending on what products they are running
• Includes DAF pretreatment to remove oils and greases and reduce the load to the bioreactor (COD about 10,000 mg/l after DAF!)
• Completely containerized at ZENON thereby minimizing site costs
• Consistently produce very high quality effluent
![Page 40: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/40.jpg)
Richardson Foods, St Mary’s, Ontario
• Permeate Numbers are as follows:– COD < 200 mg/l– BOD < 10 mg/l– TSS < 3 mg/l
• Since sewer use permit requires 300 mg/l BOD and 350 mg/l TSS, they blend waste sludge with permeate to minimize haulage costs
![Page 41: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/41.jpg)
Syndial Porto Marghera – 12.55 MGDPetrochemical Refining
Overview• ZeeWeed® MBR for the treatment
of petroleum wastewater• Commissioned in September 2005• ZENON’s largest industrial MBR• ZeeWeed® 500 membranes
Key Features• Two denitrification tanks, two
aerobic reactors, and eight ZeeWeed® UF trains
• Wastewater is treated to meet required limits and is discharged directly into the Venice lagoon
![Page 42: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/42.jpg)
Marathon Ashland Petroleum – 50,000 GPDPetrochemical Refining
Overview• ZeeWeed® MBR for the treatment
of petroleum wastewater• Commissioned in August 2003• ZeeWeed® 500 membranes
Key Features• Single train bioreactor and
ZeeWeed® UF membrane tank• Consistently removes COD,
BOD, TSS, “BTEX” compounds, and heavy metals to acceptable levels for discharge
![Page 43: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/43.jpg)
Point Judith Fisherman’s Co-op
• MBR system treats waste from squid processing
• High strength waste:» Flow- 43,000 USgpd» COD- 8,000 mg/l» BOD- 5,000 mg/l» TSS- 300 mg/l» TKN- 300 mg/l» P- 80 mg/l
• Containerized Pre-Engineered/Factory Assembled Design
• Nitrification/Denitrification
![Page 44: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/44.jpg)
Point Judith Fisherman’s Co-op
![Page 45: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/45.jpg)
Point Judith Fisherman’s Co-op
![Page 46: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/46.jpg)
Bell Carter Olive
• 800,000 USgpd
• Utilizes existing aerated lagoons
• Once fully commissioned, plant ceased discharge to the local POTW and discharged directly to river (saved flow charges, and had received capital refund)
• Containerized, Pre-Engineered, Factory Assembled Design
![Page 47: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/47.jpg)
Bell Carter Olive Co.
![Page 48: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/48.jpg)
Bell Carter Olive Co.
![Page 49: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/49.jpg)
Bell Carter Olive Co.
![Page 50: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/50.jpg)
Bell Carter Olive Co.
![Page 51: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/51.jpg)
Tertiary/Reuse References
![Page 52: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/52.jpg)
Yanshan Petrochemical – 6.9 MGDPetrochemical Refining
Overview• ZeeWeed® UF for tertiary
treatment and reuse of petroleum wastewater
• Commissioned in July 2004• ZeeWeed® 500 membranes
Key Features• Four trains ZeeWeed® UF• ZeeWeed® permeate feeds RO
for demineralized process water• Permeate TSS < 1 mg/l • Permeate Turbidity < 0.2 NTU • Permeate SDI < 3
![Page 53: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/53.jpg)
New England Power Plant
• Tertiary ZeeWeed® system to treat effluent from local POTW for feed to Demin System at Power Plant (supplied by USF!)
• Supplied as temporary system while they were “sorting out issues” with existing disc filter
• Delivers 1000 gpm of feed with SDI < 3
• Has been in operation for over 3 years now (@ $45,000 per month)!
![Page 54: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/54.jpg)
ADM, Decatur Illinois
• 5 MGD tertiary ZeeWeed® System to recycle secondary effluent to cooling towers
• Piloted on site for approximately 6 months on various applications
• Currently being expanded to 6 MGD
• Provided savings in cooling tower chemicals of > $ 1 M per year and in the words of the operator; Brad Crookshank, “The cooling towers have never run better”
![Page 55: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/55.jpg)
ADM, Decatur Illinois
![Page 56: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/56.jpg)
ADM, Decatur Illinois
![Page 57: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/57.jpg)
PEMEX Project, Minatitlan Mexico
• One of Mexico’s largest Refineries (173,200 bpd)• Wastewater treatment allows for recycle• Design wastewater flow rate of 300 lps (7 MGD)• Treatment includes:
– Dissolved air flotation– Conventional Biological Treatment– ZeeWeed Tertiary Filtration– Reverse Osmosis
• Overall water recycle efficiency is approximately 70% based on RO permeate
![Page 58: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/58.jpg)
PEMEX Refinery Minatitlan Mexico
![Page 59: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/59.jpg)
Membranes Immersed in Process Tank @ 85,000 mg/l FOG After Upset!
![Page 60: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/60.jpg)
Cassette Fully Restored After Recovery Cleaning!
![Page 61: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/61.jpg)
Bedok, SingaporeDriver: Water Re-Use
![Page 62: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/62.jpg)
Bedok, SingaporeDriver: Water Re-Use• 11.25 MGD (42,700 m3/d) capacity• Commissioned November 2002• Features:
– Treat secondary effluent from municipal WWTP– Pre-treatment to RO for water re-use– Supply high quality product water to wafer-fab industry– 5 ZeeWeed® trains
• Design performance:– Turbidity < 0.2 NTU– SDI < 3– 90% Recovery
• Plant now open for tours
![Page 63: ZENON Industrial Wastewater Treatment Overview for General Electric.](https://reader034.fdocuments.us/reader034/viewer/2022051517/56649ce35503460f949aedc2/html5/thumbnails/63.jpg)
Regional Qualification of LeadsGE Equipment Sales Reps (ESG)
GE Project Developers
ZENON Applications Engineering
Gatekeepers: Steve Low / Ed Greenwood
GE Applications Engineering
Gatekeepers: Paul Clemens / John Minnery
Formal request for quotation
ZENON Questionnaire