YL9100 HPLCThink Smart Work Better
2 YL9100 HPLC
Young Lin's HPLC is built to provide an exceptional cost/performance ratio.
Continued research and development provide high-end performance and features, whilst a state of the art manufacturing facility ensures that quality is not compromised.
With more than 20 years experience and development, we are proud to present our new generation of HPLC, YL9100 HPLC.
“
”
When the time came to replace the ageing HPLCequipment in my laboratory, the YL9100 exceededmy expectations, but not my budget. We now havegreat looking, modern HPLCs, with the performanceand functionality I required, yet at a fraction of theprice I expected. The Windows XP/Vista based CDShas proved to be a great success with my analysts.
3
Analysts can waste their time waiting for excessivebaseline noise and drift to stabilize. The YL9100 HPLC delivers a very stable baseline tomaximize analysis up-time.
One of many innovative features of the YL9100 HPLC is shielded optic design, which protects the opticalcomponents from dangerous contaminants such as fine dust or harmful gases, providing high detection sensitivity.
With automatic compressibilitycompensation minimising back-flow inthe pump, the YL9100 HPLC providesaccurate and precise flow rates.
In addition, the Seya-Namioka Monochromator and a new BlazedHolographic Concave Grating enhance light intensity, ensuring highsensitivity over the entire wavelength range.
Remarkable Stability
Superior Sensitivity
Noise Drift
Seya-NamiokaMonochromator
4 YL9100 HPLC
Powerful and Intuitive Control
21 CFR Part 11 compliance
User accountsYL-Clarity sets up access rights and passwords (including theirparameters e.g., minimum length, validity, etc.). Each user can definethe appearance of their own station.
Audit trailIt records selected events and operations into a special file andselected operations directly into a chromatogram.
Electronic signatureEach chromatogram can be signed electronically. Signature selectionis based on the username or the signature certificate.
Data Acquisition
OverlayYL-Clarity simultaneously displays a virtually unlimited number ofchromatograms and their mathematical modification; for example,mutual deductions or derivations of any order.
MeasuringSimultaneous data acquisition from up to four independentchromatographs, each chromatograph can acquire data from up to 12detectors.
Outstanding ReliabilityReliability is an essential feature of the modern HPLC and the YL9100 absolutely meets this demand.
YL9101 vacuum degasser perfectly removes dissolved gases and air bubbles, withthe added convenience of an integrated tray to safely house solvent bottles. Automatic rinsing extends the life of the pump seals.YL9130 Column Compartment with Peltier cooling providing a wide range oftemperature from 4℃ up to 90℃. Effective temperature control ensures retentiontime reproducibility and reliable data. Column temperature can also be used toimprove separation performance and analysis times.
FeaturesThe sophisticated YL-Clarity data system is easy to use and offersextensive data management plus full control of the entire YL9100HPLC product. The software is designed for 21 CFR Part 11 Complianceand through full compatibility with MS Windows XP and Vistaseamlessly handles data processing and instrument control using anultra-reliable LAN interface.
5
IntegrationThere are extensive possibilities to optimize integration. Theintegration parameters can be changed by entering globalparameters or interactively, through direct graphic modification of thebaseline.
CalibrationInternal and external standard calculation methods, calibration ofgroups of peaks and reference peaks method for better identification.
PostrunYL-Clarity automatically displays, prints, exports and starts otherprograms after the completion of a measurement.
User calculationsUsers can define custom calculations in the Result and Summarytables. Using the integrated editor you can create your own columnsfrom original columns and individual mathematical functions.
SST (System Suitability Test)The program compares up to 12 selected parameters calculatedaccording to one of three pre-selected methods (USP, EP, and JP).These calculated values are either compared to the users set limitvalues for each chromatogram separately or together for the selectedseries.
Reliable and Convenient Data Management
PDA ExtensionThis is to process data that has been acquired from selectedphoto diode array detectors. The spectral data, together withchromatograms, adds a third dimension to analytical data analysis.
GPC ExtensionsThis provides interactive and automated GPC analysis, includingrecalibration and GPC reporting, as well as simplifies the retrieval ofGPC data
Optional Module
6 YL9100 HPLC
SpecificationsSolvent Delivery Pump
In Common Compressibility compensation : AutomaticFlow range: 0.001-10ml/minFlow rate accuracy : ≤±1% at 1ml/minFlow rate precision : 0.1% RSD at 1ml/minMaximum pressure : 6000 psi> Operating range : 0-6000 psi up to 5ml/min> Operating range : 0-3000 psi up to 10ml/minSemi-automatic prime/purgeSafety & maintenance : Leak detection, Diagnostics, Error detection
YL9112 Isocratic PumpNo mixing valveOperating principle : Parallel dual-plunger pumpEasily upgraded to YL9110 Quaternary pump
YL9110 Quaternary PumpOperating principle : Parallel dual-plunger pump, Low-pressure gradientNumber of Solvent : up to 4 solventsGradient formation : 4-channel mixing valveComposition Precision : <0.1%Composition Accuracy : <0.5%
YL9111 Binary PumpOperating principle : Double Parallel dual-plunger pump, High-pressure gradientNumber of Solvents : 2
7
Detector
YL9120 UV/Vis DetectorWavelength Range : 190-900 nmData collection rate : up to 50HzLight Source : Deuterium lamp & tungsten lampNoise level : <±0.5 X 10-5 AU , 254nm, dry cellDrift : <1 X 10-4 AU/hrBandwidth : 5.5 nmWavelength Accuracy : ±1 nmWavelength Precision : ±0.1nmLinearity : >99.5% for 2.5 AU (acetone, 254nm)Path Length : 10 mm ( Analytical cell )Cell Volume : 10 uL ( Analytical cell )
YL9160 PDA DetectorSlit Bandwidth : 1.7 nmNo. of PDA Channel : 1024Pixel Resolution : 0.9 nmWavelength : 190~950 nmAnalytical Cell - Path-length : 10 mm
- Pressure : > 1500 psi- Volume : 13 ul
Noise Level : < ± 2 x 10-5 AU (Empty Cell, 1sec Rise Time, 254nm) Drift : < 2 x 10-4 AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)Wavelength Accuracy : < 1 nm (HY-1 Holmium Oxide Filter)GLP Compliance: - Photometric Accuracy, Linearity, Noise Level, Drift
- System Check
YL9170 Refractive Index DetectorRI Range : 1.00 ~ 1.75 RIUNoise : ≤ 1.3 x 10-8 RIUDrift : 0.8 x 10-7 RIU/hrLinear dynamic range : 80 x 10-5 RIUCell pressure : 6 kg/cm2 (84 psi)
8 YL9100 HPLC
YL9101 Vacuum DegasserNumber of channel : 4 ChannelsMaximum flow rate : 10 ml/min per channel
> 0 ~ 2.0ml/min per channel for 70% Gas Removed from MethanolInternal volume per channel : 925 ul per channelMaterials in contact with solvent : Teflon AF, PEEK and Glass-filled PTFE
YL9130 Column CompartmentTemperature range : 4°C (Cooling) - 90 °CTemperature stability : ±0.05°CTemperature accuracy : ±0.5°CTemperature programs : 40 StepsColumn capacity : Total 3 columns
(max. 2ea of 25cm column + 1ea of 15cm column)Heat-up time : 16 minutes from 4°C to 90°CCool-down time : 13 minutes from 90°C to 4°CLine frequency : 50/60Hz, ±5%Column switching : max. two automatic 6-port valve ( optional )
Vacuum Degasser
Column Compartment
9
Autosampler
Industry standard manual injectorAnalytical : 7725i(SUS) and 9725i(PEEK)semi-prep available
Manual Sample Injector
Rheodyne 7725i / 9725i
Other Detectors
Evaporative Light Scattering Detector(ELSD)ELSD can detect any compound less volatile than the mobile phase to low nanogram levels offering universal detection at an affordable price. It can be used to analyse components that do not have UV absorption, or those that need to be separated using gradient elution and therefore preclude the use of Refractive Index Detection.
Electrochemical Detector(ECD)ECD is a detector for HPLC applied to variable analyses such as biogenic amines, phenols, vitamins, DNA adducts, inorganic ions and amino acids.
Fluorescence Detector(FLD)FLD is a highly sensitive, scanning fluorescence detector for liquid chromatography. It provides exceptional optical performance and operational flexibility for routine and trace analysis.
YL9150 Autosampler (Alias)
The YL9150 is a high-throughput autosampler with state of the art injection technology, fast injection and washcycles, and an optional Peltier chiller/heater for samples. Full or partial loop injection along with Pressure-Assisted-Sample-Aspiration (PASA TM ) is possible.
The highly efficient needle and internal capillary washvirtually eliminates sample carry-over. Cycle time,including wash, is less than one minute.
96 standard 2ml vials (32mm x 12mm) or well plates (96or 384 capacity, deep or shallow) can be used.
Sample capacity : 2 Micro Well Plates according to SBS standards ; 96-well high/low Loop volume : 1 - 5000 ㎕ programmable, 10 mL loop optionalReproducibility :RSD ≤ 0.3% for full loop injectionsRSD ≤ 0.5% for partial loopfill injections RSD ≤ 1.0% for ㎕ pickup injections Carry-over : < 0.05 %
10 YL9100 HPLC
Optimized HPLCPost-Column Derivatization systemPickering Laboratories, Inc., California, USA, a leading company of post-column derivatization chemistries and technology, has made a contract tosupply the post-column derivatization system based on our YL9100 HPLCsystem. The PINNACLE PCX combined with YL9100 HPLC system offersthe complete package of chemicals, columns, methods and post-columnsystems and reflects the ease of use, reliability and ruggedness you havecome to expect.
1. Phosphoserine2. Taurine3. Phosphoethanolamine4. Urea5. Aspartic acid6. Hydroxyproline7. Threonine8. Serine9. Aspargine
10. Glutamic acid11. Glutamine12. Sarcosine13. a-Aminoadipic acid14. Proline15. Glycine16. Alanine17. Citrulline18. α-Amino-n-butyric acid19. Valine20. Cystine21. Methionine22. Allo-isoleucine23. Cystathionine
24. Isoleucine25. Leucine26. Tyrosine27. Phenylalanine28. β-Alanine29. β-Amino-i-butyric acid30. Homocystine31. γ-Aminobutyric acid32. Tryptophan33. Ethanolamine34. Hydroxylysines35. Ammonia36. Creatinine37. Ornithine38. Lysine39. Histidine40. 3-Methylhistidine41. 1-Methylhistidine42. Anserine43. Carnosine44. Homocarnosine45. Arginie
Chromatograms Specifications
Reagent PumpPulse free syringe pumpSingle piece ceramic barrelProgrammable flow rateFlow range : 50 - 1500 ul/minAutomatic piston washAutomatic reagent flush cycle
ReactorHeated reactor for temperature from 5°C above ambient to 130°CEasy replacement coil cartridgesRange of reactor dwell volumes; 0.1 mL to 3mL
Column HeaterProgrammable temperature gradientEasy Column access
SafeguardsIn line check valve : prevent reagent back flowReplaceable column & reagent filtersPost column system over pressureBack-pressure regulator: Applies 7 bar (100 psi) to the detector flow cell outlet (waste) to prevent detector noise and precipitation due to out-gassing or boiling
Figure 1. High-efficiency Lithium for Physiological samples using temperature gradient
- Powerful Software Control- Electronic Syringe Pump & Valve- Flexible Reactor
- Column Heater Fast & Stable- Usability Design- Special Columns & Chemistries
11
Versatile Dedicated Analyzers
Sugar AnalyzerThis system provides a simple, easy andhighly sensitive method of detecting sugars.
We provide customized systems with analysis methods and application that completely meet analysispurpose and requirement for convenience in your lab.
1. Nicotinic acid
2. Nicotinamid
3. Vitamin B6
4. Vitamin B2
5. Vitamin B1
1. Fructose
2. Glucose
3. Sucrose
4. Maltose
5. Lactose
Vitamin AnalyzerVitamins are unstable compounds, whichare easily oxidized and destroyed duringsample preparation procedures. Thisspecified vitamin analyzer is optimized forthe analysis of both water-soluble andfat-soluble vitamins by supplying entiresolutions.
Formaldehyde AnalyzerIt delivers the optimum solution for derivatization analysis offormaldehyde with the appropriate system configuration accordingto Indoor Air Quality Management which is getting interested inrecent years.
Amino Acid AnalyzerWith the Post-Column derivatization method, it can analyze naturalamino acid or hydrolyzed amino acid with a supreme sensitivity.
Carbamate AnalyzerThe analysis of pesticide using Post-Column derivatization givesanalysis and quantitative analysis by automatic samplepreparation at the same time.
Catecholamine AnalyzerIt provides all the solutions such as a sample preparation, a shorttime to stabilize the ECD (Electrochemical detector), setting foroptimum condition, keeping the sensitivity and replacement andcleaning of cell.
These Products are manufactured by Young Lin
ISO 9001-certified facility that is periodically
audited by the registering body to ensure compliance
Young Lin Bldg., 899-6 Hogye-dong, Anyang, 431-836, KoreaTEL : 82-31-428-8700 / FAX : 82-31-428-8779 E-mail : [email protected] Homepage : www.younglin.com Date : Jul., 2008