XR500/XR100 PROGRAMMING 2
Slide 1 XR500/XR100 Basic Training
Programming Part 2
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 2 Objectives
After completing this course you will:1. Understand how to program the
remaining options of the XR500/XR100.2. Be able to configure an example system.
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 3 Output Options Section
• Define the panel's bell output • Control relay outputs
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 4 Bell Cutoff Time
• Range: 1 to 99 minutes and Zero (0) disables• SIA CP-01 Installations note• Conditions for Bell cutoff time to reset• Abort message and bell cutoff time
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 5 Automatic Bell Test
• Closing Wait and bell output• Keypad arming note
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 6 Bell Action Section
• Bell Output– 4 output patterns
• Zone troubles note
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 7 Fire Type Bell Output
• Fire Type option– Default value is “P”
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 8 Burglary Type Bell Output
• Burglary Type option– Three zone types affected– Default value is “S”
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 9 Supervisory Type Bell Output
• Supervisory Type option– SV zones only– Default value is “N”
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 10 Panic Type Bell Output
• Panic Type option– PN zones only– Default value is “N”
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 11 Emergency Type Bell Output
• Emergency Type option– EM zones only– Default value is “N”
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 12 Auxiliary 1 Type Bell Output
• Auxiliary 1 type option– AUX1 zones only– Default value is “N”
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 13 Auxiliary 2 Type Bell Output
• Auxiliary 2 Type option– Aux 2 zones only– Default Value is “N”
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 14 Output Options Section
• Allows user to define use of panel outputs– Form C relays– Open Collector
• 716 Output expander note• Additional output numbers
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 15 Cutoff Output
• Cutoff Output option– Applies to panel outputs
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 16 Cutoff Time
• Cutoff Time option– 1 to 99 minutes– 0 for a continuous output
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 17 Communication Failure Output
• Comm Fail Out activates outputs based on– Main communication fail– Backup line used for comm– Network comm fail
• Used for trigger• Output turns off
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 18 Fire Alarm Output
• Activated by fire type alarm• Can use any output• Sensor Reset
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 19 Fire Trouble Output
• Activated by fire type trouble– Spv zone alarm or trouble– System monitor trouble
• Deactivated when system is normal
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 20 Panic Alarm Output
• Activated by panic type alarm• Deactivated when Panics restore
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 21 Ambush Output
• Activated with ambush code and/or Early Morning Ambush timer
• Deactivated with Sensor Reset
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 22 Entry Delay Output
• Activated with Entry Delay Timer• Deactivated by Disarm or Timer Expiration
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 23 Exit Delay Output
• Activated with Exit Delay Timer• Deactivated by Arming Process or Timer
Expiration
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 24 Ready Output
• Activated by normal disarmed burg zones• Deactivated on bad condition• Common use- Ready Light
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 25 Phone Trouble Output
• Activated by low phone line voltage– XR500 or 893
• Deactivated when voltage normalizes
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 26 Late to Close Output
• Activated by closing schedule• Note: Closing Check must be Yes• Deactivated by arming or schedule
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 27 Device Fail Output
• Activated by failed poll attempt• Deactivated by successful polling
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 28 Sensor Reset Output
• Activated by Sensor Reset• Deactivated automatically• Common use- smoke detector power
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 29 Closing Wait Output
• Activated by Closing Message• Deactivated after timer expires
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 30 Arm-Alarm Output
• Activated by an area arm• In alarm-Output pulses• Deactivated by disarm of system
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 31 DMP wireless and Arm-Alarm Output
• 1117 Wireless LED/1116 Wireless Relay Output
• 1117 battery power operation• 1116 and 572 LED function• Fast response 480-499• Slow response 450-474
– Increased battery life
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 32 Output Groups Section
• 20 Output Groups • Each Output Group links multiple outputs• Assign Output Group to profile
– Common uses• Schedules and Output Groups Note
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 33 Group Number & Name
• G1 to G20• Number and name the group to be used• Note that Output Groups 1-10 for end-user
and 11-20 are reserved.
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 34 Add Outputs to the groups
• Assigning outputs• Up to 8 outputs.
– Nesting output groups
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 35 Output Options Review
The next 15 slides are a review for the Output Option Section
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 36 Question 1
1) The panel's BELL OUTPUT does not turn on for zone troubles.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 37 Question 1
1) The panel's BELL OUTPUT does not turn on for zone troubles.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 38 Question 2
2)Selecting YES for the BELL TEST option will cause the panel to turn on the BELL OUTPUT for __________ any time all areas of the system have been armed.
A. one secondB. five secondsC. 5 minutesD. two seconds
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 39 Question 2
2)Selecting YES for the BELL TEST option will cause the panel to turn on the BELL OUTPUT for __________ any time all areas of the system have been armed.
A. one secondB. five secondsC. 5 minutesD. two seconds
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 40 Question 3
3)Which of the four BELL ACTION options are missing from the following list: Steady, _______, Temporal Code 3, None
A. StrobeB. WhoopC. PulseD. Optional
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 41 Question 3
3)Which of the four BELL ACTION options are missing from the following list: Steady, _______, Temporal Code 3, None
A. StrobeB. WhoopC. PulseD. Optional
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 42 Question 4
4) The CUTOFF OUTPUT option will accept output numbers _________.
A. 100 to 299B. 1 to 6C. 1 to 10D. 100 to 199
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 43 Question 4
4) The CUTOFF OUTPUT option will accept output numbers _________.
A. 100 to 299B. 1 to 6C. 1 to 10D. 100 to 199
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 44 Question 5
5) The ENTRY DELAY output will turn off when the system is disarmed.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 45 Question 5
5) The ENTRY DELAY output will turn off when the system is disarmed.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 46 Question 6
6) The COMM FAIL OUTPUT will turn on when the panel has failed to communicate with the receiver after __________ dial attempts.
A. 3B. 5C. 4D. 1
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 47 Question 6
6) The COMM FAIL OUTPUT will turn on when the panel has failed to communicate with the receiver after __________ dial attempts.
A. 3B. 5C. 4D. 1
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 48 Question 7
7) The ___________ output is not compatible with the CUTOFF OUTPUT option.
A. Device FailB. Phone TroubleC. AreaD. Fire Alarm
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 49 Question 7
7) The ___________ output is not compatible with the CUTOFF OUTPUT option.
A. Device FailB. Phone TroubleC. AreaD. Fire Alarm
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 50 Question 8
8) Which output will turn on with the keypad message CLOSING TIME! ?
A. AmbushB. Phone TroubleC. ReadyD. Late to Close
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 51 Question 8
8) Which output will turn on with the keypad message CLOSING TIME! ?
A. AmbushB. Phone TroubleC. ReadyD. Late to Close
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 52 Question 9
9) The _____________ output is commonly used to drive a status LED on a key switch arming system.
A. ReadyB. Exit DelayC. AmbushD. Steady
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 53 Question 9
9) The _____________ output is commonly used to drive a status LED on a key switch arming system.
A. ReadyB. Exit DelayC. AmbushD. Steady
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 54 Question 10
10)The _____________ output will turn on when the voltage on the telephone line drops below 3 VDC.
A. ReadyB. Phone TroubleC. Device FailD. Comm Fail
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 55 Question 10
10)The _____________ output will turn on when the voltage on the telephone line drops below 3 VDC.
A. ReadyB. Phone TroubleC. Device FailD. Comm Fail
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 56 Question 11
11)The _____________ output turns on when any Fire type zone is in a trouble condition.
A. Fire AlarmB. Comm FailC. Fire TroubleD. Device Fail
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 57 Question 11
11)The _____________ output turns on when any Fire type zone is in a trouble condition.
A. Fire AlarmB. Comm FailC. Fire TroubleD. Device Fail
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 58 Question 12
12) The ______ output will turn on when a supervisory type zone is placed in alarm or trouble, or when any system monitor (AC, Battery, Phone Line 1 or Phone Line 2) is placed in trouble
A. System MonitorB. Comm FailC. Device FailD. Fire Trouble
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 59 Question 12
12) The ______ output will turn on when a supervisory type zone is placed in alarm or trouble, or when any system monitor (AC, Battery, Phone Line 1 or Phone Line 2) is placed in trouble
A. System MonitorB. Comm FailC. Device FailD. Fire Trouble
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 60 Question 13
13) OUTPUT GROUPS may be configured with up to _____ individual output in a group.
A. 8B. 10C. 20D. 16
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 61 Question 13
13) OUTPUT GROUPS may be configured with up to _____ individual output in a group.
A. 8B. 10C. 20D. 16
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 62 Question 14
14) OUTPUT GROUPS G1 – G10 should be reserved for _________.
A. scheduled output applicationsB. fire applications onlyC. end-user applications D. panel-controlled applications
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 63 Question 14
14) OUTPUT GROUPS G1 – G10 should be reserved for _________.
A. scheduled output applicationsB. fire applications onlyC. end-user applications D. panel-controlled applications
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 64 Question 15
15)Output Groups may be activated as would any other system output, including by schedule.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 65 Question 15
15)Output Groups may be activated as would any other system output, including by schedule.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 66 Menu Display Section
The Menu Display section allows you to select the keypad addresses where certain control panel functions or menus are displayed.
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 67 Armed Status Display
• Armed Status option– Range 1 to 16 and 1 to 8 panel dependent
• Default: All keypads
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 68 Time Display
• Time Display option• Alternates with other items• Default: All keypads
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 69 Arm and Disarm Display
• Arm and Disarm option• Default: All keypads
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 70 Status List Section
• Status List section– Display selected by address and message
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 71 Display Keypads
• Display Keypads option• Asterisk (*) next to address number
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 72 System Monitor Troubles
• System Troubles option– Includes:
• Name displayed and Trouble Buzzer sounds• Silenced with select key• Display clears when condition clears
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 73 Fire Zone Display
• Fire Zone option• Name and zone condition displayed• Cleared with Sensor Reset• Buzzer for troubles• Default
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 74 Burglary Zone Display
• Burglary Zone option• Name and zone condition displayed• Cleared when zone normalizes• Buzzer for alarms• Default
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 75 Supervisory Zone Display
• Supervisory Zone option
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 76 Panic and Emergency
Zone Display
• Panic and Emergency option• Name displayed• Cleared when zone restores• Buzzer• Default
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 77 Auxiliary 1 and
Auxiliary 2 Zone Displays
• Aux 1 and Aux 2 option• Name displayed• Cleared when zone restores• Buzzer• Default
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 78 Menu Display & Status List Review
The next 10 slides are a review for the Menu Display & Status List Section
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 79 Question 1
1) The MENU DISPLAY section of the programming is where you identify which keypad addresses will display the:
A. armed status of the areasB. time of the dayC. day of the weekD. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 80 Question 1
1) The MENU DISPLAY section of the programming is where you identify which keypad addresses will display the:
A. armed status of the areasB. time of the dayC. day of the weekD. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 81 Question 2
2) In the MENU DISPLAY section, the ___________ option allows you to enter the keypad addresses that will display the armed condition of any burglary areas of the system.
A. Area StatusB. Arm StatusC. Arm/DisarmD. System Status
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 82 Question 2
2) In the MENU DISPLAY section, the ___________ option allows you to enter the keypad addresses that will display the armed condition of any burglary areas of the system.
A. Area StatusB. Arm StatusC. Arm/DisarmD. System Status
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 83 Question 3
3) Which of the following is not considered a SYSTEM MONITOR TROUBLE?
A. EmergencyB. Panel TamperC. AC PowerD. Phone Line 1
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 84 Question 3
3) Which of the following is not considered a SYSTEM MONITOR TROUBLE?
A. EmergencyB. Panel TamperC. AC PowerD. Phone Line 1
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 85 Question 4
4) Which of the following zone type alarms will NOT sound the keypad buzzer?
A. EmergencyB. PanicC. FireD. Any of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 86 Question 4
4) Which of the following zone type alarms will NOT sound the keypad buzzer?
A. EmergencyB. PanicC. FireD. Any of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 87 Question 5
5) To remove fire and supervisory zone alarms from the keypad display the _____________ function must be performed at the keypad.
A. Sensor ResetB. Zone Restore
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 88 Question 5
5) To remove fire and supervisory zone alarms from the keypad display the _____________ function must be performed at the keypad.
A. Sensor ResetB. Zone Restore
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 89 Question 6
6) The ______________ option allows you to control which keypad addresses users can arm and disarm from.
A. User KeypadB. ControlC. Armed DisplayD. Arm/Dis
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 90 Question 6
6) The ______________ option allows you to control which keypad addresses users can arm and disarm from.
A. User KeypadB. ControlC. Armed DisplayD. Arm/Dis
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 91 Question 7
7) The default display keypad address for PANIC and EMERGENCY zone types is:
A. 8B. NoneC. 1D. All
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 92 Question 7
7) The default display keypad address for PANIC and EMERGENCY zone types is:
A. 8B. NoneC. 1D. All
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 93 Question 8
8) By default, on a XR500, FIRE type zone alarms and troubles will be displayed at keypads ___________________.
A. with odd numbered addressesB. with even numbered addressesC. addresses 1-16 D. address 1 only
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 94 Question 8
8) By default, on a XR500, FIRE type zone alarms and troubles will be displayed at keypads ___________________.
A. with odd numbered addressesB. with even numbered addressesC. addresses 1-16 D. address 1 only
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 95 Question 9
9) Only the ________________ burglary zone that tripped will remain on the keypad display.
A. firstB. last
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 96 Question 9
9) Only the ________________ burglary zone that tripped will remain on the keypad display.
A. firstB. last
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 97 Question 10
10)If no burglary zone trips are detected for _______ minutes, Burglary Zone alarms will be cleared from the keypad display.
A. 1B. 5C. 10D. 60
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 98 Question 10
10)If no burglary zone trips are detected for _______ minutes, Burglary Zone alarms will be cleared from the keypad display.
A. 1B. 5C. 10D. 60
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 99 Printer Reports Section (XR500)
• Define messages• 462P
– Compatible printers• Note on printers
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 100 Arm and Disarm Reports
• Arming, Disarming, Late to close• Report includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 101 Zone Reports
• Zone status changes• Report includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 102 User Command Reports
• Code changes, schedule changes, outputs• Report includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 103 Door Access Reports
• Door Access activity• Report includes:• Note about Access Granted reports
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 104 Supervisory Message Reports
• System Monitor troubles• Reports includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 105 PC Log Reports Section
• Use Network or 462N• Allows logging to a PC
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 106 PC Log Address (XR500)
• Similar to printer reports– Use RS-232 or 462N
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 107 PC Log Address (XR100)
• Send messages to PC over an IP network
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 108 Arm and Disarm Reports
• Arming, Disarming, Late to close• Report includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 109 Zone Reports
• Zone status changes• Report includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 110 User Command Reports
• Code changes, schedule changes, outputs• Report includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 111 Door Access Reports
• Door Access activity• Report includes:• Note about Access Granted reports
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 112 Supervisory Message Reports
• System Monitor troubles• Reports includes:
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 113 Printer and PC Log Reports
ReviewThe next 10 slides are a review for the
Printer and PC Log Reports Section
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 114 Question 1
1) Printing with the XR500 of any report listed in the PRINTER REPORTS section requires the use of a DMP ______________ module, if the onboard RS-232 is not being used for this purpose.
A. testB. 462P C. output expanderD. 462N
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 115 Question 1
1) Printing with the XR500 of any report listed in the PRINTER REPORTS section requires the use of a DMP ______________ module, if the onboard RS-232 is not being used for this purpose.
A. testB. 462P C. output expanderD. 462N
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 116 Question 2
2) Enabling the ____________ option with the XR500 allows opening and closing reports to be printed on a local printer.
A. Arm/DisB. SupervisoryC. SystemD. User
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 117 Question 2
2) Enabling the ____________ option with the XR500 allows opening and closing reports to be printed on a local printer.
A. Arm/DisB. SupervisoryC. SystemD. User
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 118 Question 3
3) Before XR500 zone alarm messages can be printed on the local printer, the SUPERVISORY MESSAGE option must be set to YES.
True False
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 119 Question 3
3) Before XR500 zone alarm messages can be printed on the local printer, the SUPERVISORY MESSAGE option must be set to YES.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 120 Question 4
4) To print SYSTEM MONITOR TROUBLES on the local printer, which option must be set to YES?
A. none of theseB. MonitorsC. SystemD. Supervisory
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 121 Question 4
4) To print SYSTEM MONITOR TROUBLES on the local printer, which option must be set to YES?
A. none of theseB. MonitorsC. SystemD. Supervisory
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 122 Question 5
5) (XR500) PC LOG REPORTS can be sent to PC LOG software directly through a 462N Network Interface module.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 123 Question 5
5) (XR500) PC LOG REPORTS can be sent to PC LOG software directly through a 462N Network Interface module.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 124 Question 6
6) PC LOG REPORTS can be sent to an alternate IP address by using the ____________________ string.
A. Serial OutputB. Program OutputC. PC Log Address D. Host Output
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 125 Question 6
6) PC LOG REPORTS can be sent to an alternate IP address by using the ____________________ string.
A. Serial OutputB. Program OutputC. PC Log Address D. Host Output
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 126 Question 7
7) Output status changes _________________ sent through the PC LOG REPORT function.
A. areB. are not
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 127 Question 7
7) Output status changes _________________ sent through the PC LOG REPORT function.
A. areB. are not
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 128 Question 8
8) Zone status change reports can be sent to both the local printer and the PC LOG software.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 129 Question 8
8) Zone status change reports can be sent to both the local printer and the PC LOG software.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 130 Question 9
9) The ALARM BELL SILENCED message is always printed on the local printer when any valid User silences an alarm.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 131 Question 9
9) The ALARM BELL SILENCED message is always printed on the local printer when any valid User silences an alarm.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 132 Question 10
10)EXIT ERROR messages _________________ sent to the PC LOG output.
A. areB. are not
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 133 Question 10
10)EXIT ERROR messages _________________ sent to the PC LOG output.
A. areB. are not
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 134 Area Information Section
• Controls parameters for areas on the panel
• Notes on non-24 hour zones and naming an area
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 135 Exit Delay Timer
• Defines exit delay for all areas• Exit Delay operation• Timer range• Tone frequency/operation• Note: Exit Error
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 136 CP-01 and Exit Delay
• Note: When CP-01 is NO• Exit Error Operation
– Two different sequences1. Entry Delay 1 EX type zone sequence2. Entry Delay 2 to 4 EX type zone sequence
• Note: CP-01 if set to no, Entry Delay 1 changes to sequence 2
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 137 Burglary Bell Output
• Activated by burg zone alarm condition• Follows bell output• Three ways to deactivate
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 138 Opening/Closing Reports
• Sends message when area is armed or disarmed
• Note on additional programming
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 139 Closing Check
• Verify area arming• Closing Time! and buzzer• Area Schedules are used-displays “LATE”• Select Key silences buzzer• Late to Close message
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 140 Closing Code
• Yes=Valid user code for arming• No=No code required• Note for user arming reporting
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 141 Any Bypass
• Yes = Any valid user code• No = Proper authority• Note on Bypass Zone user menu
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 142 Area Schedules
• Schedule uses– Arming/Disarming– Opening/Closing windows
• Yes = Each area has it’s own Shifts• No = All area’s have the same shift• Note: All/Perim and Home/Sleep/Away systems
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 143 Early Ambush
• Range: 1 to 15 and Zero – Time before S15 is sent
• Description of Early Ambush in use• Note: Availability
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 144 Area Number Selection
• Area Number prompt– XR500 area range– XR100 area range
• Note on All/Perimeter or Home/Sleep/Away
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 145 All/Perimeter Selection
• When All/Perimeter is selected as the system type, program the Interior and Perimeter areas as needed.
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 146 Home/Sleep/Away Selection
• When Home/Sleep/Away is selected as the system type, program the Interior, Bedroom, and Perimeter areas as needed.
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 147 Area Name
• An inactive area is “Unused”• Clearing an area name• Note on making active areas inactive
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 148 Account Number
• Account number prompt– Area Account number function
• Note on defaults
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 149 Reports by Account Number
MESSAGE SENT REPORTING ACCOUNT #
System Monitor Trbl Main Account #
Fire Alarm/Trbl Main Account #
Supervisory Alrm/Trbl Main Account #
Auto Recall Test Main Account #
Alarm Silence Area 1 Account #
Sensor Reset Area 1 Account #
System Test Area 1 Account #
Time Set Area 1 Account #
MESSAGE SENT REPORTING ACCOUNT #
Open/Close Reports Area's Account #
System Recently Armed Area 1 Account #
Alarm Bell Silenced Area 1 Account #
Schedule Change Rprt Area 1 Account #
Code Change Report Area 1 Account #
Access Denied Area 1 Account #
Access Granted Area 1 Account #
Emergency Zones Area 1 Account #
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 150 Automatic Arming
• Automatic Arming option– Yes = Will auto arm according to the area’s schedule
• If no schedule is present-arming will occur
• Closing check sequence• Note on CP-01 installations
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 151 Bad Zone Options
• Bad Zone option– How the panel will act with a bad zone
• Bypass• Force• Refuse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 152 Automatic Disarming
• Yes = Will auto disarm according to area’s schedule– If no schedule is present- disarming will not occur
• Notes on reporting and CP-01 UL installations
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 153 Armed Output Number
• Activates when the area is armed• Deactivated when area is disarmed• Note on User Menu Output function
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 154 Late to Close Output
• Activated by armed condition• Deactivated by key press
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 155 Late to Arm Delay
• Delay for rearming• Range 4 to 250 minutes• Default 60 minutes• Note on Late Arm Delay vs. Re Arm Delay
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 156 Bank, Safe and Vault (XR500N/XR500E only)
• Yes = schedule can’t be changed while armed– If no schedule exists, cannot disarm
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 157 Bank, Safe and Vault Notes• Bank, Safe and Vault Operational Notes:
• Note 1: Program schedules before arming: A Bank Safe & Vault area can only be disarmed during scheduled times.
• If you arm the area before programming a schedule, the panel must be reset before the area can be disarmed from a keypad OR the Bank Safe & Vault option in Area Information must be set to NO.
• Note 2: Zones assigned to areas programmed for Bank Safe & Vault cannot be bypassed or force armed.
• Note 3: Do not assign Bank Safe & Vault area to an Arming zone. Arming zones can disarm Bank Safe & Vault areas outside of a schedule.
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 158 Common Area
• Common area description• Note on common areas and codes
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 159 Arm First Area
• Arms if another area arms• Arm First and faulted zones• Note on Arm First and keypad arming
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 160 Two Man Rule (XR500N/XR500E only)
• Requires two codes for– Disarm– Access
• Two Man Rule procedure
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 161 Area Information Review
The next 10 slides are a review for the Area Information Section
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 162 Question 1
1)An area is activated by _____________.
A. the user’s profileB. the armed outputC. giving it a numberD. giving it a name
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 163 Question 1
1)An area is activated by _____________.
A. the user’s profileB. the armed outputC. giving it a numberD. giving it a name
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 164 Question 2
2)When the EXIT DELAY time starts, activity on all non-24 hour zones that are assigned to an area containing an ENTRY/EXIT zone will be ___________.
A. an Exit ErrorB. displayed in the status listC. logged in the event bufferD. ignored by the panel
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 165 Question 2
2)When the EXIT DELAY time starts, activity on all non-24 hour zones that are assigned to an area containing an ENTRY/EXIT zone will be ___________.
A. an Exit ErrorB. displayed in the status listC. logged in the event bufferD. ignored by the panel
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 166 Question 3
3) When activated, the BURG BELL output will be turned off when _______________.
A. any of theseB. Bell Cutoff Time expiresC. silenced by userD. the area is disarmed
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 167 Question 3
3) When activated, the BURG BELL output will be turned off when _______________.
A. any of theseB. Bell Cutoff Time expiresC. silenced by userD. the area is disarmed
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 168 Question 4
4) When sending Opening and Closing reports is YES in Area Information, the O/C USER option must also be YES in the _________ programming section before opening and closing reports will be sent.
A. HOST LOG REPORTSB. COMMUNICATIONC. AREA INFORMATIOND. SYSTEM REPORTS
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 169 Question 4
4) When sending Opening and Closing reports is YES in Area Information, the O/C USER option must also be YES in the _________ programming section before opening and closing reports will be sent.
A. HOST LOG REPORTSB. COMMUNICATIONC. AREA INFORMATIOND. SYSTEM REPORTS
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 170 Question 5
5) For the panel to require an arming code, this option must be set to yes.
A. CLS CODEB. O/C USER REPORTS
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 171 Question 5
5) For the panel to require an arming code, this option must be set to yes.
A. CLS CODEB. O/C USER REPORTS
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 172 Question 6
6) Selecting YES to the ANY BYPS option allows bad zones to be bypassed using any valid user code _______________.
A. at anytimeB. during disarmed periodsC. during the arming sequenceD. inside of their assigned Shift Schedule
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 173 Question 6
6) Selecting YES to the ANY BYPS option allows bad zones to be bypassed using any valid user code _______________.
A. at anytimeB. during disarmed periodsC. during the arming sequenceD. inside of their assigned Shift Schedule
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 174 Question 7
7) The EXIT DELAY option determines how long your customers have to exit any area that has an ENTRY/EXIT zone.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 175 Question 7
7) The EXIT DELAY option determines how long your customers have to exit any area that has an ENTRY/EXIT zone.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 176 Question 8
8) The OPENING/CLOSING report option can be enabled to tell the panel to send a report when any area is armed or disarmed.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 177 Question 8
8) The OPENING/CLOSING report option can be enabled to tell the panel to send a report when any area is armed or disarmed.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 178 Question 9
9) The BAD ZONES option is where you determine what the panel will do when it encounters a bad zone during ____________.
A. none of theseB. auto disarming onlyC. auto arming onlyD. arming or disarming
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 179 Question 9
9) The BAD ZONES option is where you determine what the panel will do when it encounters a bad zone during ____________.
A. none of theseB. auto disarming onlyC. auto arming onlyD. arming or disarming
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 180 Question 10
10)The COMMON AREA option allows an area to be armed with the last area that is armed and disarmed with the ______________ area that is disarmed.
A. firstB. last
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 181 Question 10
10)The COMMON AREA option allows an area to be armed with the last area that is armed and disarmed with the ______________ area that is disarmed.
A. firstB. last
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 182 Zone Information Section
• Controls parameters for zones on the panel
• Assigning zones
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 183 Zone Number
• Panel zones– Expansion zones for the XR500 and XR100
• LX Bus XR500• LX Bus XR100
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 184 XR500 Keypad Bus Zone Numbering
Address 1 =zones 11-14address 2 =zones 21-24address 3 =zones 31-34address 4 =zones 41-44address 5 =zones 51-54address 6 =zones 61-64address 7 =zones 71-74address 8 =zones 81-84
address 9 =zones 91-94address 10 =zones 101-104address 11 =zones 111-114address 12 =zones 121-124address 13 =zones 131-134address 14 =zones 141-144address 15 =zones 151-154address 16 =zones 161-164
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 185 XR100 Keypad Bus Zone Numbering
address 1 =zones 11-14address 2 =zones 21-24address 3 =zones 31-34address 4 =zones 41-44address 5 =zones 51-54address 6 =zones 61-64address 7 =zones 71-74address 8 =zones 81-84
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 186 Zone Name
• “Unused” is an unnamed zone• Clearing and entering a new name• Name up to 16 characters• Note about deleting a zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 187 Zone Type
• How the zone will act based on type• Basic characteristics• Changing Zone Type• The Zone Types: -- , NT, DY, EX
FI , PN, EM, SV A1, A2, FV, AR
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 188 Blank & Night Zone Types
• First four zones- Used as burglary zones– A Blank Zone– A Night Zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 189 Day & Exit Zone Types
• Burglary use zones (cont.)– A Day Zone– An Exit Zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 190 Fire & Panic Zone Types
• 24 Hour Zones– A Fire Zone– A Panic Zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 191 Emergency & Supervisory Zone
Types
• 24 Hour Zones cont.– An Emergency Zone– A Supervisory Zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 192 Auxiliary 1 & Auxiliary 2 Zone Types
• Other zone types– An Auxiliary 1 Zone– An Auxiliary 2 Zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 193 Fire Verify & Arming Zone Types
• Other zone types cont.– A Fire Verify Zone– An Arming Zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 194 Fire Bell Output
• Fire Bell Output– Activated by any alarm on a FI, FV, or SV
zone– 5 Ways for the output to deactivate
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 195 Area Number
• Area Number that this zone will be assigned to • Valid area numbers • Note on alarms and troubles display
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 196 Arming Zone Area Assignments
• Arming Zone Area Assignment– Assign the areas to the arming zone– Area 1 is default
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 197 Arming Zone Area Assignments
(Cont.)
• All/Perimeter or Home/Sleep/Away option
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 198 Toggle, Arm, Disarm Arming Zone Styles
• Toggle arming style operation• Arm arming style operation• Disarm arming style operation
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 199 Step & Maintain Arming Zone Styles
• Step arming style (for wireless arming)– Short condition operation– Open condition operation
• Maintain arming style operation
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 200 Next Zone?
• Select “YES” for a new zone• Select “NO” for alarm action of same zone
– Allows for customization of reports, outputs etc.
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 201 Extended Zone Information
• Selecting “YES” leaves remaining defaults• Selecting “NO” enters extended zone programming
– Allows for unusual applications• Messages, outputs, wireless options can be individually
controlled• Options are dependent on zone type
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 202 DMP Wireless
Zone Information
• Wireless option– Select “NO” for hard wired zone– Select “YES” for wireless options
• System Options - House Code• J23 Jumper position• Zones for DMP Wireless Key Fob• Zones for Other DMP Wireless
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 203 Transmitter Serial Number
• Eight digit serial number (DMP Wireless)• “Already In Use” prompt• Note on the Stop routine• Where is the wireless information stored?
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 204 Transmitter Contact Selection
• 1101 and 1102 Programming• Internal vs. External contacts• Note on 1101 dual zones• Programming example
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 205 Transmitter Input Contact
• 1114 Four Zone Expander programming– Same serial number used– Must use consecutive zone numbers– Default Contact is 1
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 206 External Contact Type
• 1101 or 1102– Yes if a normally open contact is being used– No if a normally closed contact is being used
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 207 Supervision Time
• Supervision Time– Time is in minutes (0) for unsupervised operation
• Missing condition– Check in based on supervision time
• Note on supervision timer
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 208 LED Operation
• LED Operation– Yes turns on LED for PN or EM– No to disable– Open and Tamper operate LED – Defaults
• Note on UL installations
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 209 1100 Series Key Fobs
• 1100 Series Key Fob– House Code range– Zone Range
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 210 User Number
• User Number– Uses for Key Fob– Viewed by user number in Display Events– Defaults
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 211 Serial Number
• Serial Number– Include leading zeros on Key Fob
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 212 Supervision Time
• Key Fob Supervision Time– Defaults
• Note on timer restart
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 213 Number of Buttons
• Number of Buttons– 1,2,4
• Note on Button Action and One Button Fobs
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 214 Button Selection (Four Buttons)
• Four Button Fob– Display for Four Button Fob only– Default button assignments
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 215 Button Selection (Two Buttons)
• Display for two button fob– Default button assignments
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 216 Button Action
• Button Action for each button– Defaults are displayed
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 217 Button Action (Cont.)
• Button Action (Cont.)-PN -Out -PN2 -Rst-EM -Un -EM2
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 218 Button Press Time
• Button Press Time to initiate message– Used with Arm, Disarm, Toggle, Status, Output and
Sensor Reset• Note on when button press isn’t programmable• Short –one half second• Long – two seconds
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 219 Arm/Disarm Area Selection
• Arm/Disarm Area Selection
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 220 All/Perimeter or Home/Away selection
• All/Perimeter or Home/Away selection– Assign area to be armed– Choose between (Perim or All) OR (Home, Sleep, or
Away)
• Note on Areas not available
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 221 Output Action
• Output Action– Assign output operation– An output activated by PN, PN2, EM, or
EM2 will turn off on disarmed by Key Fob• Std, Pls, Mom, Tgl, Off
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 222 Output Number
• Assign particular output• Activated by PN, PN2, EM, or EM2
• Valid output ranges
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 223 Inovonics Wireless Zone Information (XR500)
• Inovonics Wireless Zone Information (XR500)– Select “No” if zone is hard wired– Select “Yes” if using an Inovonics FA device
• Before programming Inovonics Transmitters• Inovonics zone range
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 224 Check In Time
• Check In Time• Missing report
– Supervision window• Check in sequence• Unsupervised option
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 225 Internal Contact
• Internal Contact– Select “NO” if using external wiring– Select “YES” if using supplied magnet
• Note on install guide
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 226 End Of Line
• End Of Line option– Select “NO” if a resistor is not being used– Select “YES” if a resistor is being used
• Note on Inovonics resistor• See the Inovonics install guide for specifics
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 227 Normally Open
• Normally Open option– Select “NO” if the contacts are closed– Select “YES” if the contacts are open
• Next Zone? NO YES prompt– Select “NO” to continue with this zone– Select “YES” to program another zone
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 228 Alarm Action
• Alarm Action– Allows zone customization
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 229 Alarm Action Table
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 230 The Four Zone Conditions
• The Four Zone Conditions-D/O -D/S-A/O -A/S
• Three Configurable parameters for each zone condition– Message– Output– Action
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 231 Message (Report to Transmit)
• Message Prompt– Messages to choose from
-Alarm -Trouble-Local -Disable
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 232 Message (Report to Transmit)Continued
• Messages continued• Door Prop• Sensor Reset• Cancel Ambush
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 233 Output Number
• Activated regardless of message• Output number range• Note on LX-Bus polling cycle
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 234 Output Action
• Defines how the output behaves (if assigned)
-Steady -Pulse-Momentary -Follow
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 235 Swinger Bypass
• Swinger Bypass– Used with “runaway” conditions– Select “YES” to bypass– Select “NO” to disable this function
• Note on Swinger Bypass Operation
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 236 Prewarn Address
• Prewarn option– Determines which keypads display “Enter
Code:” • Defaults to all addresses
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 237 Entry Delay
• Allows selection of one of the four timers• Note on System Options and entry timers
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 238 Zone Retard
• For Fire, Supervisory, Aux1, or Aux2 zone types• Select “YES” to use Zone Retard Delay• Select “NO” to turn off this feature• Note on zone retard function
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 239 Presignal Address
• To sound desired keypad while in retard delay• How to silence• To enable keypad, enter address• All panel addresses may be used• Note on presignal prompt
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 240 Fast Response
• Length of time zone detected– Select “NO” for normal response– Select “YES” for fast response
• Note on LX Bus response
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 241 Cross Zone
• Requires one or more armed zones to fault within a specific time period
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 242 Priority Zone
• Uses– Safes, vaults and other sensitive areas– Area will not arm unless zone is normal– Select “YES” to utilize this feature
• Note on priority zones
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 243 Zone Number
• Priority zone is the final option– Then taken to this prompt– If finished press the Backarrow key
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 244 Program Transmitters
(Inovonics wireless)– Backarrow from Zone No to this prompt– Select “YES” to enter Inovonics programming
mode– Select “NO” to exit Zone Information
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 245 Connect Transmitter
• Enter transmitter number to be programmed• Connect transmitter• Press reset• Confirmation prompt• Connect Transmitter prompt and repeat
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 246 Additional Inovonics Wireless
Information
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 247 Connect FA100
• Procedure for programming transmitter• Press command if a FA100 is not used• Note on 472 card and FA426
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 248 Zone Information Review
The next 10 slides are a review for the Zone Information Section
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 249 Question 1
1) Entering a 'space' in the zone name is achieved by pressing __________ then the third Select key.
A. backarrowB. 9C. commandD. 0
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 250 Question 1
1) Entering a 'space' in the zone name is achieved by pressing __________ then the third Select key.
A. backarrowB. 9C. commandD. 0
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 251 Question 2
2) Fire Bell Output is available for ___________________ zone types.
A. Fire, Fire Verify and SupervisoryB. Fire and Fire verifyC. 24 hourD. 715 zone expander
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 252 Question 2
2) Fire Bell Output is available for ___________________ zone types.
A. Fire, Fire Verify and SupervisoryB. Fire and Fire verifyC. 24 hourD. 715 zone expander
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 253 Question 3
3) Fire Bell Output is silenced when _________________.
A. valid user code is entered to silenceB. bell cutoff time expiresC. silence key of 630F keypad is pressedD. all of the above
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 254 Question 3
3) Fire Bell Output is silenced when _________________.
A. valid user code is entered to silenceB. bell cutoff time expiresC. silence key of 630F keypad is pressedD. all of the above
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 255 Question 4
4) Alarm Action prompts for 24-hour zones begin with _______________.
A. armed openB. next zone? No YesC. zone no:-D. disarmed open
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 256 Question 4
4) Alarm Action prompts for 24-hour zones begin with _______________.
A. armed openB. next zone? No YesC. zone no:-D. disarmed open
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 257 Question 5
5) To get tone at the keypad when a zone is shorted during the retard delay, __________ must be set to YES.
A. maintainB. prewarnC. presignalD. retard delay
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 258 Question 5
5) To get tone at the keypad when a zone is shorted during the retard delay, __________ must be set to YES.
A. maintainB. prewarnC. presignalD. retard delay
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 259 Question 6
6) Which type of zone does NOT have LOCAL as an option in the Armed Short message?
A. SupervisoryB. DayC. ArmingD. Auxiliary 2
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 260 Question 6
6) Which type of zone does NOT have LOCAL as an option in the Armed Short message?
A. SupervisoryB. DayC. ArmingD. Auxiliary 2
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 261 Question 7
7) When FAST RESPONSE is set to NO, the amount of time that it takes for the panel to see zone condition changes is:
A. 200 msB. 167 msC. 500 msD. 267 ms
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 262 Question 7
7) When FAST RESPONSE is set to NO, the amount of time that it takes for the panel to see zone condition changes is:
A. 200 msB. 167 msC. 500 msD. 267 ms
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 263 Question 8
8) When learning Inovonics wireless transmitters on the XR500 panel, connect the transmitter to the 472 Interface card and press ___________.
A. any Select keyB. CommandC. J16 panel resetD. the transmitter’s reset button
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 264 Question 8
8) When learning Inovonics wireless transmitters on the XR500 panel, connect the transmitter to the 472 Interface card and press ___________.
A. any Select keyB. CommandC. J16 panel resetD. the transmitter’s reset button
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 265 Question 9
9) XR500 zone expansion is limited to 100 zones per Interface card except the 472 Inovonics 900Mhz Interface Card, which allows up to 200 wireless zones. How many Model 472 cards may be used on the XR500?
A. only oneB. up to two
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 266 Question 9
9) XR500 zone expansion is limited to 100 zones per Interface card except the 472 Inovonics 900Mhz Interface Card, which allows up to 200 wireless zones. How many Model 472 cards may be used on the XR500?
A. only oneB. up to two
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 267 Question 10
10) A 16-zone expander installed on the onboard LX-Bus is addressed 16. What would be the zone number for the FIFTH zone on this expander?
A. 520B. 521C. 121D. 120
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 268 Question 10
10) A 16-zone expander installed on the onboard LX-Bus is addressed 16. What would be the zone number for the FIFTH zone on this expander?
A. 520B. 521C. 121D. 120
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 269 Stop Section
• Exit programming here– Four events occur during the stop routine
• Note in SIA CP-01
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 270 Important Note
• Flash Updating– Remotely– At site– Convenient
• Note on the significance of the stop routine and the panels flash memory
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 271 Stop Diagnostic Feature (XR500)
• Identify missing LX Bus cards• Four different diagnostic displays
- No LX- Bus Card - No Wireless Card- No Printer Card - No Host Card
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 272 Set Lockout Code
• Security code for programming• Can change anytime• Lockout codes and Remote Link
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 273 Enter Lockout Code
• Procedure on entering a lockout code• Numerical limit• Confirmation prompt• Exiting programming• Note on deleting a Lockout Code
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 274 Stop/Lockout Code Review
The next 5 slides are a review for the Stop/Lockout Code review
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 275 Question 1
1) The STOP routine exits the programmer mode and prepares the panel for normal operation.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 276 Question 1
1) The STOP routine exits the programmer mode and prepares the panel for normal operation.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 277 Question 2
2) The STOP routine will do the following:
A. turn off all outputsB. clear the status listC. disarm all areasD. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 278 Question 2
2) The STOP routine will do the following:
A. turn off all outputsB. clear the status listC. disarm all areasD. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 279 Question 3
3) The XR500 STOP diagnostic function will display any LX-Bus cards the panel is expecting, that are not installed.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 280 Question 3
3) The XR500 STOP diagnostic function will display any LX-Bus cards the panel is expecting, that are not installed.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 281 Question 4
4) The SET LOCKOUT CODE will allow you to enter a security code that must be entered to get into the panel's programming mode.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 282 Question 4
4) The SET LOCKOUT CODE will allow you to enter a security code that must be entered to get into the panel's programming mode.
TrueFalse
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 283 Question 5
5) The LOCKOUT CODE can be from ________________ digits.
A. 1 to 8B. 3 to 5
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 284 Question 5
5) The LOCKOUT CODE can be from ________________ digits.
A. 1 to 8B. 3 to 5
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 285 An Example SystemNow that we know how all of the different programming options
work together, let's use the floor plan below as an example and work through configuring the system.
W arehouse (Area 3)
Office (Area 2) •
Lobby (Area 1)
Vault (Area 5)
Break Room (Area 4)
Doo
r 7
Doo
r 4
Dv c 5
KP 1
Door 3
Do
or 2
Dv c 6
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 286 System Planning• Develop a plan
– Areas– Users– Access Only or Disarm and Access– Schedules– Profiles– Device Setup– Door Schedules and Device Setup
Warehouse (Area 3)
Office (Area 2) •
Lobby (Area 1)
Vault (Area 5)
Break Room (Area 4)
Doo
r 7
Doo
r 4
Dvc 5
KP 1
Door 3
Doo
r 2
Dvc 6
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 287 In this example site, the location includes: Five areas, five access doors (one is used for anti-
passback detection at the Vault) and four different groups of users.
To configure the system we need to program the following information:
1)Areas 2)Device Setup 3)Schedules 4)Output Schedules 5)User Codes 6)Profiles
W arehouse (Area 3)
Office (Area 2) •
Lobby (Area 1)
Vault (Area 5)
Break Room (Area 4)
Doo
r 7
Do
or 4
Dvc 5
KP 1
Door 3
Doo
r 2
Dvc 6
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 288 Configuring Access Control• First, program the Area Information section.
W a r e h o u s e ( A re a 3 )
O f f ic e ( A re a 2 ) •
L o b b y ( A re a 1 )
V a u l t ( A re a 5 )
B r e a k R o o m ( A r e a 4 )
Doo
r 7
Do
or 4
D v c 5
K P 1
D o o r 3
Doo
r 2
D v c 6
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 289 Device Setup - Access Areas• The XR500/XR100 access control hinges on Device Setup
Programming– Used to restrict access
• First decide on the number of devices– Then name each device– Put in Area Access for each device
• Note on null Access field
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 290 Device Setup – Egress Areas• Egress field
– Anti-passback• Egress is granted when Areas match
– Must be used for Access later– Buffer events
• Egress field blank to deactivate– Example system
• Anti-passback operation
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 291 Device Setup – Strike time, Fire exit and Output
groups• Strike Time function
– Range– Default
• Example at hand• Fire Exit use
– Sensor Reset• Output Group option
– Uses
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 292 Device Setup – Schedule override
• Example: Lobby Door– Unlocks during business hours– Snow day
• Schedule Override option– Use
• Area arming and Door Locking– Use of multiple area numbers
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 293 Schedule Programming - Types
• Example Output Schedule use• Example Shift Schedule use• Door and Output Schedules
– Primary use• 100 Output Schedules available
– 8 different schedules for each output• Shift schedules• Each area may have up to 4 Shifts
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 294 Schedule Programming - Doors
• Example – Lobby Door to automatically lock– Requires an output schedule
• See table below for unlock (ON) and lock (OFF) times for door 2 (D2)
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 295 Schedule Programming - Shifts
• Example restrict access to an area• Day time shift access and Cleaning crew access• Table below lists schedules• Shift assignment also in Profiles
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 296 Profile Programming• Final step
– Defining user authority level (Profiles)• Before Profiles are created, consider the following:
-Who -Access to what areas-What areas to arm/disarm -What menus to access
• These issues should be addressed early on– Different restrictions will result in different profiles
• Total number of profiles available• Example site uses 4 different profiles
– The next four slides will detail each profile• Administrator• Management• Cleaning Crew• Warehouse Employees
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 297 The Administrator Profile
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 298 The Management Profile
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 299 The Cleaning Crew Profile
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 300 The Warehouse Profile
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 301 Profile Options• Many configuration possibilities with a
profile– Most options deal with the user menu
• The next slide will show the options available
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 302 Profile Options
• Profile Options– Many configurations
• Most are access to different menu options
• Profiles 1 through 10 are pre-configured for A/P or H/S/A
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 303 User Code Processing Flow Chart
The flow chart illustrate the access process
• Panel compares programming related to code presented
• If something doesn’t match up error will be generated
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 304 Error messages
• Invalid Code• No Authority• Invalid Area• Armed Area• Invalid Time• Failed to Exit
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 305 Example Site Review
The next 9 slides are a review for the Example Site review
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 306 Question 1
1) Each AREA to be used in the system must have _____________.
A. assigned zoneB. a nameC. access doorsD. a schedule
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 307 Question 1
1) Each AREA to be used in the system must have _____________.
A. assigned zoneB. a nameC. access doorsD. a schedule
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 308 Question 2
2) If the ACCESS and EGRESS fields are left blank, any valid code will be ____________ access at that device, regardless of the __________.
A. granted, scheduleB. denied, scheduleC. granted, profileD. denied, profile
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 309 Question 2
2) If the ACCESS and EGRESS fields are left blank, any valid code will be ____________ access at that device, regardless of the __________.
A. granted, scheduleB. denied, scheduleC. granted, profileD. denied, profile
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 310 Question 3
3) If anti-passback operation is not needed, leave the _______ field blank.
A. egressB. access C. overrideD. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 311 Question 3
3) If anti-passback operation is not needed, leave the _______ field blank.
A. egressB. access C. overrideD. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 312 Question 4
4) The STRIKE TIME can be configured from ______________ seconds.
A. 0 – 120B. 0 – 250C. 5 – 250D. 1 – 250
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 313 Question 4
4) The STRIKE TIME can be configured from ______________ seconds.
A. 0 – 120B. 0 – 250C. 5 – 250D. 1 – 250
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 314 Question 5
5) If there are multiple area numbers in the ACCESS field, the OVERRIDE option will lock the door when all areas in the field are ___________.
A. in alarmB. bypassed C. disarmed D. armed
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 315 Question 5
5) If there are multiple area numbers in the ACCESS field, the OVERRIDE option will lock the door when all areas in the field are ___________.
A. in alarmB. bypassed C. disarmed D. armed
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 316 Question 6
6) If an XR100 has 6 areas programmed, how many possible Shift schedules could be created?
A. 12B. 32C. 24D. 6
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 317 Question 6
6) If an XR100 has 6 areas programmed, how many possible Shift schedules could be created?
A. 12B. 32C. 24D. 6
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 318 Question 7
7) Which type of schedules are used to restrict access to certain individuals?
A. Area SchedulesB. Shift SchedulesC. Door SchedulesD. none of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
Slide 319 Question 7
7) Which type of schedules are used to restrict access to certain individuals?
A. Area SchedulesB. Shift SchedulesC. Door SchedulesD. none of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 320 Question 8
8) Which of these profile options below would allow the user to enter shift schedules into the panel?
A. Extend B. SchedulesC. AllowD. Anytime
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 321 Question 8
8) Which of these profile options below would allow the user to enter shift schedules into the panel?
A. Extend B. SchedulesC. AllowD. Anytime
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
XR500/XR100 PROGRAMMING 2
8/08
Slide 322 Question 9
9) Output Groups can be used for ______________.
A. starting the coffee makerB. lighting control C. elevator control D. elevator recallE. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 323 Question 9
9) Output Groups can be used for ______________.
A. starting the coffee makerB. lighting control C. elevator control D. elevator recallE. all of these
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
___________________________________
Slide 324 Congratulations!
You have completed the XR500/XR100 Training course.