XMM 1Michael Smith, ESAC EPIC PN Monitoring Provided by Michael Smith.

8
1 Michael Smith, ESAC XMM EPIC PN Monitoring Provided by Michael Smith
  • date post

    21-Dec-2015
  • Category

    Documents

  • view

    215
  • download

    0

Transcript of XMM 1Michael Smith, ESAC EPIC PN Monitoring Provided by Michael Smith.

1Michael Smith, ESAC

XMM

EPIC PN Monitoring

Provided by Michael Smith

XMM-Newton

2

Michael Smith, ESAC

PN Bad Pixel & Offset Monitoring

Since last meeting:

• FF offset map calculation using 50 frames (as opposed to 100) since ~ rev 842.

• Additional bad pixel (type ‘H’, i.e. not up-linked) included in EPN_BADPIX CCFs:

CCD 1, (RAWX,RAWY) = (56,75)

XMM-Newton

3

Michael Smith, ESAC

Hot Pixels (E > 744 ADU in Offset Map)

XMM-Newton

4

Michael Smith, ESAC

Offset Map Mean

XMM-Newton

5

Michael Smith, ESAC

Offset Map Variance

XMM-Newton

6

Michael Smith, ESAC

Noisy Pixels (> 1% Occurrence in CalClosed)

XMM-Newton

7

Michael Smith, ESAC

Energy monitoring

• over-correction with time tailed out with new CTI CCF (13) for all modes

• eFF mode over-correction improved (see talk M.Pilar Esquej)

• Still not understood problem of SW mode (CC data not applicable for SW, however in first approximation a over correction would be expected:we see an under-correction ???

XMM-Newton

8

Michael Smith, ESAC

Conclusions

• Hot pixel situation is stable.

• Offset Map mean is stable again after small excursions around rev 600 (mentioned in previous Ops meetings).

• Offset Map variance for FF mode has changed after ~ rev 842; probably related to the introduction of 50 frame offset calculation.

The change is more pronounced in some CCDs (e.g. Quadrant 1 and CCD11) than in others.

• Noisy pixel situation is stable.

Current Bad Pixel Table still valid.