VARNA Products
XD9 Whisper Vane Transfer Pump
Compact, Heavy Duty, Industrial, Quality
1HP IEC Metric MotorFlow rate up to 9 GPM or 34 LPMPressure up to 100 psi or 6.9barUnique Whisper-Vane design: Direct ShaftCoupling, Simple, Reliable, Efficient, SelfPriming, Quiet Running, Compact, Long Life.
VARNA Products 4305 Business Dr.
Cameron Park, CA 95682, USAwww.VarnaProducts.com
1 (888) 676-7770+1 (530) 676-7770 (International)
Printed in USA 7/10/12 © 2008 VARNA Products
Engineered | Innovatio
Wetted Materials: Carburized Carbon Steel Anodized Aluminum Viton
Feature and Specifications Comparison 60Hz 50Hz
Operating voltage 230/460 200/400
9 GPM
(34 LPM)
Rated Pressure
Whisper-Vane positive displacement technology, Self Priming
SAE straight thread O-ring Ports (J1926 ISO 11926) (Not compatible with pipe thread )
Max Ambient air temperature
Rated current in Amps. 3.2/1.6 3.8/1.9
Motor service factor
Max oil temperature
Max oil viscosity
Flow rate at 30psi (2 bar)
>5ft (1.5m)
-16 (1" or 25mm)
28 LPM
1.15
~6,000 cSt
392°f (200°c)
104°f (40°c)
100psi (6.9 bar)
7/27/2019 XD9_OilPump
http://slidepdf.com/reader/full/xd9oilpump 2/4
Printed in USA 7/10/12 © 2008 VARNA Products
General
The XD9 pump delivers up to 9 gpm (34 l/m) of oil flow. It is a self-priming and quiet-running
vane pump for use in a wide variety of transfer or circulating applications with non-corrosivefluids such as oils and coolants. It can handle fluids with poor lubricity or low film strength, andproduce over 100 psi (6.9 bar) pressure.
Plumbing Considerations
Excessive pressure drop caused by small pipes can be detrimental to system performance.Relative to ‘hydraulic pumps’ this is a high flow, low pressure pump, optimized for efficiency intransfer applications. Small suction hoses/pipes will starve the pump and reduce output flow bycausing cavitation. Small pressure pipes will create excessive backpressure that will exceed therating of the pump. Therefore, elbows and long runs of pipe should be avoided. Each elbow andeach inch of pipe has a cumulative effect. Pluming loses with cold or high viscosity fluid caneasily add up to a large percent of available pressure when the plumbing is too restrictive.
The pump itself produces flow not pressure. Like a turnstile, every rotation of the pump delivers ametered volume to the other side. Whatever system is connected to the pump has flowresistance, which is the source of the backpressure as the pump works to maintain flow.
It is recommended that hose or pipe no smaller than 1” (25mm) be used and that the suctionhose in particular is kept as short as possible and no longer than 36”.
Motor Protection
Class 20 motor protection in the motor starter is recommended.
Application Engineering
It is challenging to address every possible installation type. We are always happy to help inchoosing an appropriate installation setup. Give us a call for engineering assistance and support.888-676-7774
Engineer’s Corner VARNA Products XD9 Transfer Pump
7/27/2019 XD9_OilPump
http://slidepdf.com/reader/full/xd9oilpump 3/4
0 1 2 3 4 5 6
0
5
10
15
20
25
30
35
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
0 10 20 30 40 50 60 70 80 90 100
Pump Pressure (Bar)
P u m p F l o w ( L P M )
P u m p F l o w ( G P M )
Pump Pressure (psi)
XD-9 Pump Flow Performance
0 1 2 3 4 5 6
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
0 10 20 30 40 50 60 70 80 90 100
Pump Pressure (Bar)
M o t o
r C u r r e n t ( A M P S . )
Pump Pressure (psi)
XD-9 Motor Current Performance
Current @ 1400 cSt
Current @ 1 cSt
Motor Full Load Rating
7/27/2019 XD9_OilPump