Slide 1Orion Telecom Networks Inc. - 2010 Slide 1
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
xcvcxv Updated: April, 2010Orion Telecom Networks Inc. - 2010
VCL-MegaConnectVCL-MegaConnectTMTM
16 Port Plus - T1 16 Port Plus - T1 Monitoring GroomerMonitoring Groomer
Product PresentationProduct Presentation
Slide 2Orion Telecom Networks Inc. - 2010 Slide 2
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
Product OverviewProduct Overview
Used for non-intrusively monitoring T1 links (i.e. without disturbing "live” T1 traffic)
16 T1 receivers for monitoring up to 8, bi-directional T1 links
Built-in non-blocking DCX at DS-0 level to cross-connect the Input T1 Ports to the
Output T1 Ports.
Grooming facility - allows the user to select and aggregate the 64Kbps time-slots from
various T1 inputs to a few T1 outputs
4 additional outputs T1 ports to connect the aggregated time-slots to user's protocol
analyzers, test probes, etc.
2U high rack-space. Compact 19-inch stand-alone unit.
Powered by and operates on a -48V DC power input.
Slide 3Orion Telecom Networks Inc. - 2010 Slide 3
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
Application DiagramApplication Diagram
Slide 4Orion Telecom Networks Inc. - 2010 Slide 4
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
Application DiagramApplication Diagram
Slide 5Orion Telecom Networks Inc. - 2010 Slide 5
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
VCL-MegaConnectVCL-MegaConnectTMTM 16 Port Plus - T1 Monitoring Groomer - 16 Port Plus - T1 Monitoring Groomer - Front View:Front View:
Slide 6Orion Telecom Networks Inc. - 2010 Slide 6
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
VCL-MegaConnectVCL-MegaConnectTMTM 16 Port Plus - T1 Monitoring Groomer - 16 Port Plus - T1 Monitoring Groomer - Back View:Back View:
Slide 7Orion Telecom Networks Inc. - 2010 Slide 7
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
Programming FeaturesProgramming Features
Status MonitoringStatus Monitoring
T1 Synchronization Clock Selection (internal, incoming T1 clock, 2.048 MHz TTL External Clock)
Enabling or disabling T1 Ports (masking) of the T1 Ports that are not in use
Creating a cross-connect between T1s at DS-O level (single time-slot level) using the CLI text commands or Windows based GUI (Graphical User Interface)
Telnet for remote programming.
T1 Synchronization Clock Status
Status of alarms
Enabled / Disabled status of T1 Ports
Monitoring of the VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer, status and configuration.
Slide 8Orion Telecom Networks Inc. - 2010 Slide 8
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
Loss of incoming signal at any T1 Port
Configuration error alarm
T1 Synchronization Clock Status
1 to 16 T1 Ports - LED indicators to indicate the status of each T1 Monitoring Port
3 Volts Power Supply
-48V DC Input Voltage
Configuration Error
External alarm output - through a dry contact relay.
Indications and Alarm MonitoringIndications and Alarm Monitoring
Telnet for remote configuration and monitoring
Windows based GUI (Graphical User Interface) with a in-built feature to back-up and restore existing configuration files.
Management OptionsManagement Options
Slide 9Orion Telecom Networks Inc. - 2010 Slide 9
VCL-MegaConnectTM 16 Port Plus - T1 Monitoring Groomer
Thank you for your attentionThank you for your attention
For more details visit us at our Website at
http://www.oriontelecom.com
Regional Office: Miami, Florida
Orion Telecom Networks Inc.4000 Ponce de Leon Blvd. Suite 470,Coral Gables, FL 33146 U.S.A.Phone: 1-305-777-0419, Fax: 1-305-777-0201E-mail: [email protected]: http://www.oriontelecom.com
Headquarters: Phoenix, Arizona
Orion Telecom Networks Inc.16810, Avenue of the Fountains, Suite # 108, Fountain Hills, AZ 85268 U.S.A.Phone: +1 480-816-8672, Fax: +1 480-816-0115E-mail: [email protected]: http://www.oriontelecom.com