www.quick-software-line.com
Settings
- Settings centralized on SOURCE system
- The environment contains everything needed for the settings and for the replications follow-up
Replication
- SIP, Sequence Integrity Processing: unique engine to process all journal entries
- CCI, Core Cycle Information: synchronous replication loop, with real time acknowledgements
- Automatic journaling management
Quick-EDD/HA concepts
www.quick-software-line.com
Controls and Synchronization
- EDC : Synchronization by comparison; only differences are sent to the target system
- Linked to replication acknowledgements
- Activated by IOA: Independent Object Audit
Jobs Follow-Up (JFP)
- Replication of jobs information (status, detail of SBMJOB), mandatory in case of fail-over
Smart Remote Staging (SRS)
- Pause of the replications, thanks to temporary storage of the journal entries on target system: continuous data protection, for example during backup made on the target system, instead of the production one
Quick-EDD/HA Concepts
www.quick-software-line.com
Tools
- External audit, control and supervision tools
- Sources of programs are available to adapt to different systems
Supervision GUI
- Light client to monitor at a glance Quick-EDD/HA on all your systems and partitions
Switch
-Switch scenarios allow a simple and efficient adaptation to all sites and contexts
-Management of Switch-over / Fail-over / Return on production system / Systems migrations
Quick-EDD/HA Concepts
www.quick-software-line.com
Settings
The « Environment » Object- One single object to describe the entire perimeter
- Settings manage the 5 system domains- User libraries (including QGPL, QUSRSYS, …)
- System objects (Profiles, authorization lists, configuration …)
- IFS, including QDLS
- Spools files
- System values
- Following your selections, Quick-EDD/HA will automatically analyze your applications in order to build the objects list and the list of journals which are necessary for the replication
- The environment is automatically replicated on the target system in order to access the information in case of switch
Settings are done only on SOURCE system
www.quick-software-line.com
Settings
Target system description
Access to the selections in each
domain
Journals manageme
nt rules
Replication general
parameters
www.quick-software-line.com
JournalingAny journaling organization is supported • Unlimited number of journals• Quick-EDD/HA can manage the start of journaling for
applications which don’t have journals already
• Support of all journaling functions• MINENTDTA• Journal Cache and *STANDBY mode (SS1 Option 42) • Before image – Commit/Roll-back
• Receivers management can be entirely done by Quick-EDD/HA - for different external needs, receivers can be
totally or partially managed by other processes
• « Not wished » journals entries can be ignored by the reading process to avoid communications overload
www.quick-software-line.com
JournalingJournals
management rules
Receivers detachment
optionsReceiversdeletion options
Cache management if activated
www.quick-software-line.com
Replication
Quick-EDD/HA fits any kind of organization- Without restrictions regarding the number of journals
- Without restrictions regarding the place of the objects (journals, PF/LF, …)
A unique engine to guarantee the sequence: SIP
- All the journals are simultaneously handled to guarantee the operations sequence
- Audit journal events are integrated in the same processSynchronous communications: CCI- Source system is informed in real time
- All the events are acknowledged in real time
www.quick-software-line.com
SIP – Sequence Integrity Processing
Rebuild of the
operations sequence
before sending
Simultaneous
reading of all the journals of the
perimeter
DB / IFS / Audit events are all
integrated at the same level
www.quick-software-line.com
CCI – Core Cycle Information
Detection from the journal
Sending on TARGET system
Direct application on TARGET object Real-time acknowledgement
SOURCE system is always informed about the replications status
www.quick-software-line.com
Real time acknowledgement <-> SynchroAn acknowledgement validates any replication operation-Any replicated event is acknowledged in real time.
The SOURCE system manages the whole process.
-In case of negative acknowledgement, AUTOMATIC EXECUTION of the object synchronization is made for an immediate repair of the abnormality.
Unique synchronization function- EDC module allows to compare two objects to detect the
differences. Only these differences are sent on the network to protect the bandwidth
- The synchronization does not use the SAV / RST function to avoid any locking of object on the source system
- Once synchronized, the object comes back in the replication loop
www.quick-software-line.com
IOA - Independent Object Audit
IOA function monitors the TARGET system - Scheduled or on demand control of all or a part of
perimeter objects
- Check of the objects presence and correspondence (for the 5 domains of the system)
Dynamic repair of the differences- Each difference detected by IOA function triggers
immediately a synchronization to repair the object – no manual action is required.
- A spool file report is created after each execution
www.quick-software-line.com
Synchronization EDC and IOA
JRNERR
Instant synchronization by comparison and
sending of the differences only
EDC
IOA
Diff ?
Replication errors, such as permanent controls, call the synchronization module for every noticed abnormality. The abnormality is repaired
in real time
www.quick-software-line.com
Jobs Follow-up and management during a Fail-Over
What happened on production at the moment of the failure?
What Jobs were active? What Jobs were in JOBQ ?
Unique and mandatory function for HA
JFP Track
Production Job status
Help for decision in case of Fail-over
Job submission in their corresponding JOBQ
Jobs Follow-up
Submission function to get an immediate start of the target system
www.quick-software-line.com
SRS ACTIVATEDJournal entries are stored in
a dedicated space.Temporary halting
acknowledgement back to production.
Target system Data can be used for backups, queries…
Synchronous ModeRegular process and direct apply of the
update on the target system
SRS Staging on the
target system
Automated or On Demand Apply
Operations on the target system are easier (Query, backup …)
On Demand Applying process
Smart Remote Staging
www.quick-software-line.com
Tools
Tools which offer additional functions :- Control functions
- Objects, data, perimeter control- Supervision of the replication process
- Monitoring functions
- Interception of all severe messages (gravity > 30)
- Sending by e-mail; SNMP; MSGQ – JOBLOG is attached
- Specific objects saves - Scheduler, NetServer, TCP/IP, RDB entries, …- WRKDIRE, Distribution list, …
For a total adaptation, all tools are delivered with source files.
www.quick-software-line.com
1 to 4 e-mail recipients
SMTP server used for e-mails
routing
Tools: SampleOptions to
monitor messages
www.quick-software-line.com
Ease of use – GUI - General InformationGUI monitoring
Monitor all servers/lpar’s on a single screen
Auto refresh and access to all environments
Active?
Latency?
In Sync?
5 mn a day!
www.quick-software-line.com
Switch
Quick-EDD/HA switch- Only one function to perform Quick-EDD/HA role-swap,
for the switch and for the return on production system.
- Transparent management of the journaling, triggers, constraints and identity fields
- In case of fail-over: Automatic management of the « commit/rollback » transactions, jobs follow-up, stored journal entries
Adapted tools - Switch scenarios allowing to adapt to all contexts
- Switch over and switch back of specific objects
www.quick-software-line.com
Switch
PMEDHSWI command
• Environment role-swap RCV SND to prepare replication from former target to former production system
• Creation of new journals receivers – positionning in the environment to give the replication starting point