Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8 Industrial Radiography Supplies and...

22
www.irss.com

Transcript of Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8 Industrial Radiography Supplies and...

Page 1: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

www.irss.com

Page 2: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

About IRSS

14705 116 ave Edmonton, AbT5m-3E8www.irss.ca

Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta, Canada, is in its first years of operations and has become the leading supplier of RT products in Western Canada.

IR’s vision for the future will be to expand into other NDE disciplines and develop an educational center focusing on radiation safety and product training. IR will also become a leader in digital technology working with those companies that are willing to help us develop products that will perform under Western Canada’s unique climate and production techniques.

Page 3: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Analog Vs Digital

Page 4: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Displays

DMC 2000-SOR/R

RDS 30

RadEye G

PEN Dosimeter

Canadian Admiral

Analog Digital

Page 5: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Different models have Different Ranges and are displayed using different scales

Digital models have an easy to read display that goes from 0.1mR to 1000R and can with the push of a button can even display the rate as a double check to a survey meter

Dosimeter Displays

Page 6: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Response Time Comparison

Page 7: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Set Up

Dose Rate = 600mR/hr

Distance to Center of Detector = 11.79”D(inches) = 22.2(mCi/mRhr)ˆ½

Activity of reference SourceCs-137, s/n S1307 on October 27, 2008

= 168.88 mCi

Page 8: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Analog

Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity 168.89mCi

Canadian AdmiralModel CCD-100-10S/N 02085

Display not scaled with proportional increments, makes it hard to read current field strength at a glance

Jumps between 500mR/hr and 700mR/hr

Meter set on high scale If on low, the scale range would have to be changed manually by the user

Page 9: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Digital

Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity 168.89mCi

RDS 30S/N 270700

Scale range is automatic and requires no user intervention

Display easily read

Stable Field Measurement

Page 10: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Direct Response Time Comparision

Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity 168.89mCi

RDS 30S/N 270700

Canadian AdmiralModel CCD-100-10S/N 02085

Note: Canadian Admiral set on Low Scale

Page 11: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Direct Response Time Comparision

Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity 168.89mCi

RDS 30S/N 270700

Canadian AdmiralModel CCD-100-10S/N 02085

Note: Canadian Admiral set on High Scale

Page 12: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,
Page 13: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Dose Rate Alarm Set-Up Screen- Using Wireless IRDA Connection to Communicate with PC

Dose Alarm Set-Up Screen- Using Wireless IRDA Connection to Communicate with PC

Meter Status Screenshot

History Reading Screenshot

Page 14: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

PC Interface Screenshot

Page 15: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

SOR/R OverviewGeneral Features• Solid State (silicon diode) detector• Personnel & Area Monitoring capability• Linear response to 1000 R/hr• Energy Range: 50 keV - 6 MeV• Self Testing/Diagnostics (battery, detector)• Internal Memory “Histogram”• Standard Calculator Battery - over 2000 hrs• Multi-Configuration:

- Dose, Rate and Time Alarm/Warning- Satellite or Autonomous operation- Hands-Free communication

Page 16: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

SOR/R OverviewGeneral Features• Alarm Thresholds

- Primary Alarm for Dose and Dose Rate- Pre-Alarms (warnings) for Dose and Dose Rate

• Histogram – “Events History” - 700 intervals- 10 sec, 1 min, 10 min, 1 hr, 24 hr- Stamps dose increment, date, time at selected time interval; records alarm or error indication automatically

Page 17: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

SOR/R Overview General Features• Optical Detector Check

- Expose diode to light source every 10 minutes- Three consecutive failures, detector fault alarm (def det)

Test-to-failure concept!• Background Radiation check

- 10 uR/hr: one pulse ~ 10 minutes- No counts in pre-determined time: det. Fault

• Battery (voltage)check every 10 minutes

Page 18: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Display Messages – Internal Faults

Defective Detector:Remove from serviceReturn for repair/replacement

Defective History:Start new histogram using Reader – Entry/Exit

Defective Battery:Battery discharged/removed;Change battery, check for short Or defective ground wire

Defective EEPROM:Problem accessing data in Memory; remove battery for72 hrs,reinstall

Defective Calibration:Calibration data integrityproblem; re-calibrate dosimeter

Defective Componentfor Pulse Counting:Remove from service; return For repair/replacement

Defective External Detector/Initialization:External detector calibration value corrupted; Data integrity suspect or corrupted; re-initialize calibration or system parameters. ContactMGPI for help

Drained Battery:Remove battery for 72 hrs; inspect for damage

Page 19: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

History

Customizable Alarm/Alarm Warning ThresholdsAudible Alarms and Warnings Have Different Tone

HistoryTime Stamp- Can be set to record down to an interval of every 10 seconds Detailed Graph- allows user to display and calculate dose increments down to an interval of every 10 secondsRecords can be electronically saved or printed

Dose and Dose Rate thresholds Have Different Audible Tones

Page 20: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

New Designs to meet user preferences and demands

New Technology can be used in traditional designs

In Development

Page 21: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

ALARA and Safety Advantages

Digital Dosimeters display instantaneous, easy to read and accurate dose levels

Digital Survey Meters do not need to be adjusted by the user to change scalesDigital Survey Meters

Digital Dosimeters

Digital Dosimeter History reports can be analyzed, saved electronically, and matched to TLD reports

Customizable audible alarm thresholds

Customizable audible alarm thresholdsHave a scale going up too 1000R, Dose will not run meter off scale

Page 22: Www.irss.com. About IRSS 14705 116 ave Edmonton, Ab T5m-3E8  Industrial Radiography Supplies and Services Inc. (IR), located in Edmonton Alberta,

Questions