Workshop Eurocodes – Background and...

34
Eurocode 8 Part 5: Foundations, retaining structures and geotechnical aspects (EN1998-5: 2003) Ezio Faccioli ([email protected]) Workshop Eurocodes – Background and Applications Brussels, February 18-20, 2008

Transcript of Workshop Eurocodes – Background and...

Page 1: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Eurocode 8 Part 5: Foundations, retaining structures and geotechnical aspects (EN1998-5: 2003)Ezio Faccioli ([email protected])

Workshop Eurocodes – Background and Applications

Brussels, February 18-20, 2008

Page 2: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Outline• Object and salient characteristics of EN1998-5:2003

• Ground properties (strength, stiffness and damping parameters)

• Design seismic action and its dependence on ground type

• Requirements of construction site and of foundations soils

• Foundation system: shallow and deep foundations

• Earth retaining structures

Page 3: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Object of EN1998-5:2003 The norm:

• “rules for the siting and foundation soil of structures forearthquake resistance”, and

• “covers the design of different foundation systems, .. of earth retaining structures ……under seismic actions”

From Part 1:”…. It shall be verified that both the foundation elements and the foundation soil are able to resist the action effects resulting from the response of the superstructure without substantial permanent deformations. ”

Page 4: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Salient characteristics and innovative aspects• Complementarity with Eurocode 7 (EN 1997e), which does not cover earthquake resistant

design.

• Introduction and use of dynamic soil properties (τcyc, shear wave velocity vs and damping) in addition to standard static properties (tan φ′, cu, qu).

“4.2.2 (2) The profile of the shear wave propagation velocity in the subsoil shall be regarded as the most reliable predictor of the site dependent characteristics of the seismic action at stable sites”

• Different approaches to safety and strength verifications, depending on seismicity level and type of soil.

“4.1.2.3 (8) Simplified methods (of slope stability analysis), such as the pseudo-static ones, shall not be used for for soils capable of developing high pore water pressures or significant degradation of stiffness under cyclic loading”.

• In situ investigations, or gathering of reliable equivalent data, to determine the elastic design response spectrum.

• Recognition of seismically-induced permanent ground deformations as a design criterion.

Page 5: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

• Static undrained parameter values (cu, tanφ’ ) can generally be used for strength verifications, with recommended values of material partial factors (γm).

• For cohesionless soil the strength parameter is the cyclic undrained shear strength τcy,u which should take the possible pore pressure build-up into account.

• The soil shear modulus:

and the soil damping ratio are introduced, for use in SSI calculations, as well as their dependence on the seismic shear strain in the soil (through the design ground acceleration).

• For the evaluation of the liquefaction potential, the cyclic soil resistance against liquefaction (based on field performance in past earthquakes) is used, which depends on SPT blowcount or cone penetration resistance.

Ground properties

2Sv

gwG =

Page 6: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

The reference ground motion model at a point on the surface is the accelerationelastic response spectrum:

The dependence is established through:•The constant soil factor S, which does not modify the spectrum shape

but only amplifies it, and takes a single value for each ground type ;•The “control periods” TB ,TC ,TD which modify the shape by enlarging

the spectral plateau

Se (T) = ag f (T; S,TB ,TC ,TD )

Remark: it would be desirable to make S a smoothly varying function of Vs30, e. g.:

with bv and Va constants

VbaS VVS )/( 30=

Design seismic action: dependence on ground type

Page 7: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

∑=

=

N,1i S

i30,S

iVh

30V Weighted VS

∑= N,1i

ithi ti

Particular cases:

Types S1,S2 Special studies

Identification of ground typesD

epth

[m]

Page 8: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

In seismic geotechnical verifications, such as:

• Slope stability • Liquefaction hazard occurrence• Stability of retaining works

the sesmic action is directly determined by the design ground acceleration agS,multiplied by a reductive coefficient, as follows:•(0.5 agS) /g seismic coefficient for pseudo-static slope stability verifications• 0.65 agS effective acceleration for checking the liquefaction potential in a

saturated sand deposit• [(ag/g)S)]/r seismic coefficient for computing the dynamic thrust in the

pseudo-static verification of a retaining work.

Seismic action: dependence on ground type

Page 9: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

OBJECTIVE: minimise hazards caused by ground rupture, instability, liquefaction in the event of an earthquakeGROUND STABILITY VERIFICATIONS:

• Slope limit state = excessive permanent displacements of ground mass

• Topographic amplification coefficients for the seismic action to be used for slope angles >15°

• Pseudo-static verification of stability is allowed but:

− Cyclic Δu and strength degradation in saturated soils must be accounted for in areas with

design ground acceleration > 0.15 g

− Development of cyclic Δu and cyclic stiffness degradation are not high

• Limit state condition can be checked by simplified dynamic model (rigid block)

Topographic amplification factors (ST)Type of

topographic profile Sketch Average slopeangle,α ST

Isolated cliff andslope > 15° 1.2

15° to 30° 1.2Ridge with crest

width significantlyless than base width

> 30° 1.4

α

α

Amplitude response (averaged over frequency) along slopes of different geometry

Requirements for siting and foundation soils

Page 10: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Example of simplified 3D representation of a settlement on a crest: Baiardo

1

2

2

1

y = 0,3946x + 565,43

y = -0,3873x + 1184,8

500

600

700

800

900

1000

0 200 400 600 800 1000 1200 1400 1600 1800

d [m]

Transv. cross section1

h[m]

α1 α2α1 = 22.6

α2 = 22.2

y = -0,3009x + 1171,7

y = -0,0759x + 928,52

0

200

400

600

800

1000

1200

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Long. cross section2

h[m]

d [m]

α1 = 4.3

α2 = 17.2α2

α1

Page 11: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

“(1) Buildings of importance classes II, III, IV defined in EN 1998-1:2004, 4.2.5, shall

not be erected in the immediate vicinity of tectonic faults recognised as being

seismically active in official documents issued by competent national authorities.

(2) An absence of movement in the Late Quaternary may be used to identify non

active faults for most structures that are not critical for public safety.

(3) Special geological investigations shall be carried out for urban planning purposes

and for important structures to be erected near potentially active faults in areas of

high seismicity, in order to determine the ensuing hazard in terms of ground

rupture and the severity of ground shaking..”

Requirements of the construction site:Proximity to seismically active surface faults

Page 12: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Izmit, Turkey, M 7.3 earthquake of August 1999Fault rupture (double stranded) near Golcuk

Page 13: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Izmit, Turkey, M 7.3 earthquake of August 1999Details of fault rupture

Page 14: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Izmit, Turkey, M 7.3 earthquake of August 1999Damages to buildings

Page 15: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

The guidelines are not unduly conservative, because evaluation of liquefaction susceptibility can be omitted if:- The sandy soil layer or lens lies at more than 15

m depth from ground surface- The design ground acceleration is less than

0.15 g and, at the same time: NSPT is sufficiently high, or the content of plastic fines in the soil is sufficiently high.

A minimum safety factor of 1.25 (in terms of shear stresses) is recommended.

Relationship between stress ratios causingliquefaction and N1 (60) values forclean and silty sands for M=7,5 earthquakes.

Requirements for siting and foundation soilsPOTENTIALLY LIQUEFIABLE SOILS

Detailed guidelines and charts (Annex B) are provided for evaluating the liquefaction susceptibility of saturated cohesionless foundation soils through the well known empirical method based on NSPT or CPT resistance.

Page 16: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

CRITERIA:• The vs profile at the site is taken as “the most reliable predictor of the site dependent characteristics of

the seismic action at stable sites”

• Estimating the vs profile by empirical correlations (e. g. with NSPT) is allowed, provided the inherentscatter is taken into account

OBIECTIVES: Determine average subsoil profile for selecting design response spectrum and dynamic soil properties

Vs profile at Catania strong motion station on

deep sediments

(ground type C/D)

Ground investigations and studies

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 0.5 1 1.5 2T [s]

SA [

g]

Catania, 13 dec. 1990 - NS

Page 17: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Indicative reduction factors for vs or Gmax, and for internal damping in the soil are provided as a function of shear strain amplitude (through the peak ground acceleration)

Ground investigations and studies

0

0.2

0.4

0.6

0.8

1

0.0001 0.001 0.01 0.1 1 10

Shear Strain (%)

G/G

max

0

5

10

15

20

25

30

35

Dam

ping

Rat

io (%

)

Shear Modulus

Damping Ratio

Page 18: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Foundation systemBASIC RULEOnly one foundation type to be used for the same structure, unless this consists of dynamicallyindependent units. E. g. use of piles and shallow foundations in the same structure must beavoided, except for bridges and pipelines.

DESIGN ACTION EFFECTSAction effects transmitted to the foundations are evaluated according to capacity design considerations for dissipative structures (high ductility), while allowable seismic action combination applies for non-dissipative structures (essentially responding in the elastic range).

DIRECT FOUNDATIONS (Footings)Stability of footings is to be checked against sliding failure, i. e.

and against bearing capacity failure (Annex F, see following two slides). Factors to be taken intoaccount include: Inclination and eccentricity of structural loiad, inertia forces in the soil, porepressure effects, non-linear soil behaviour.

Vsd ≤ Nsd tan δ + Epdshear friction lateralforce resistance resistance

Page 19: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Bounding surface of external loadsA single expression has been obtained for both cohesive and granular soils; it is introduced in Annex F of Part 5

3D view of bounding surface Cross-sections for vanishing F and different load eccentricities

HD

HDLD

LD

e/B = 0

e/B = 1/6

Foundation system

Page 20: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Piles and piers

Should be designed to resist both:

(a) Inertia forces from the superstructure, and(b) Kinematic forces due to the eartquake-induced soil deformations.

The latter apply if all of the following conditions occur:

b1. Class D, S1, or S2 soil profile with consecutive layers of sharply contrasting stiffness

b2. Design ground acceleration > 0.10 g, and

b3. The supported structure is of importance category III or IV.

Although piles will generally be designed to remain elastic, they may under certainconditions develop plastic hinges at their head.

Foundation system

Page 21: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Kinematic forces on pilesKinematic forces induced by earthquake on piles in “stable” soils

s(z): seismically induced horizontaldisplacements in the soil

Designearthquake

Page 22: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Kinematic forces induced by earthquake on piles in “unstable” loosesoils

Kinematic forces on piles

Designearthquake

Stable soil

Stablesoil

Unstable loosesandy soil

Horizontaldisplacementsinduced in soil byeqk (“flow failure”)

Page 23: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

(NISEE slide collection)

Effects of kinematic forces on piles

Page 24: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

General requirements and considerations

• Permanent displacements/tilting may be acceptable, provided functional or aesthetic

requirements are not violated

• Structural choice is based on static loads , but seismic action may lead to different solution

• Build-up of significant PWP in backfill or supported soil is to be absolutely avoided

• Methods of analysis should in principle account for:

- inertial and interaction effects between structure and soil (even non-linear)

- hydrodynamic effects in the presence of water (in the soil, and on outer face of wall)

- compatibility of deformations of soil, wall, and free tendons)

NB: After introducing requirements for general methods of analysis, the code only provides prescriptions for pseudo-static verifications

Earth retaining structures

Page 25: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Experimental observations (flexible retaining walls)

1) Effects on retaining walls in historical earthquakes

- Liquifiable soils (harbour facilities) Collapse (0.6 – 4m displacements)

Loma Prieta (California, 1989) – MW=7.1

Kobe (Giappone, 1995) – MW=6.9

Bhuj (India, 2001) – MW=7.6

- Non-liquifiable soils Good behaviour (<10cm displacements)

Northridge (California, 1994) – MW=6.8

Kobe (Giappone, 1995) – MW=6.9

Taiwan (1999) – MW=7.6

2) Dynamic experimental tests

- Shaking table

- Dynamic centrifuge tests

Page 26: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Simplified (pseudo-static) analysis: the seismic action can be reduced by kind of ductility factor r:

kh = ag γI S/rkv = ± 0,5 kh (Spectrum Type 1) kv = ± 0,33 kh (Spectrum Type 2)

Values of reduction factor r and residual displacement

Type of retaining structure r Acceptable

residual displacement, dr (mm)

Free gravity walls that can accept a displacement

As above, but less”tolerant”

Flexural reinforced concrete walls, anchored or braced walls, reinforced concrete walls founded on vertical piles, restrained basement walls and bridge abutments

2

1,5

1

300agγI S / g

200ag γI S / g

0

For loose, saturated granular soils, r = 1 and FS against liquefaction not less than 2.

The provisions for pseudo-static analysis follow a standard approach (Mononobe and Okabe), given in Annex E.

Earth retaining structures

Page 27: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

• Foundation soil The following need be verified:− Stability of slope− Stability w. r. to failure by sliding and loss of bearing capacity, for shallow

foundation. Design actions: permanent gravity loads, horizontal thrust Ed , seismic action.

• Anchorages They shall assure equilibrium and have a sufficient capacity to adapt to the seismic deformations of the ground . The distance Le between the anchor and the wall shall exceed the distance Ls, required for non-seismic loads :

• Backfill material must be immune from liquefaction. • Structural strength under the combination of the seismic action with other possible loads, equilibrium must

be achieved without exceeding the strength of any structural element:

Resistance and stability verifications

Le = Ls (1 + 1.5 S ag)

Rd > SdRd : design resistance of the element, evaluated as for the non seismic situation Sd : design value of the action effect, as obtained from the analysis.

Earth retaining structures

Page 28: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Examples of numerical analyses: simple flexible wall(from M. Eng. Thesis of O. Zanoli, Politecnico di Milano, Dec. 2007)

Soil profile propertiesGround categories B, C, D: governed by Vs,30Coarse grained, dry, γS=20kN/m3, Φ=34°, c’=0, ψ=0°, δA=0°, δP= ΦRC flexible wallUnit weight γRC=25kN/m3, νRC=0.3, ERC=28GPaExcavation depth h=3, 5, 7m + Embedment (d)

h3d5 h5d8 h7d11

Excavation d. [m] 3 5 7

Embedment [m] 5 8 11

H total [m] 8 13 18

⎪⎩

⎪⎨

=

=

ga

Sr

k

k

gRh

v

1

0

⎪⎪⎩

⎪⎪⎨

=

Δ+++=Δ+=

PEdPE

AEAdAEdAdAE

KdP

KdhKdhPPP

2,

22,,,

21

)()(21

γ

γγ

0

10

20

30

40

50

60

0 200 400 600 800 1000vs [m/s]

Pro

fond

ità [m

]

Suolo D Suolo C Suolo B

h

d

d2

KpE,kKpE,d

Ka,kKa,d

ΔPaE,d

Pa,d

PpE,d

Pre-dimensioning (EC 8)

1) Design strength : tan φd=tan φ /1.25

2) Seismic coefficients

3) Thrusts

4) Rotational equilibrium w. r. to base5) 20% increase in embedment d

Page 29: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Examples of numerical analyses: simple flexible wall (fromM. Eng. Thesis of O. Zanoli, Politecnico di Milano, Dec. 2007)

Material modelsSoil: coarse grained, homogeneous, Vs=156m/s, elastic-plastic non associated constitutive

model, Mohr-Coulomb rupture criterion(f=32°).

Flexible wall: 13m height, 5m excavation, linear elastic behaviour, E=28 GPa, ν=0.3.

150m

55m 30mBase excitation2 groups of 7 accelerograms onground type A

Zone I Zone II(amax=0.35g) (amax=0.25g)

Average response spectramatching EC8 elastic spectrum

0

2

4

6

8

10

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

T[s]

Acc

. spe

ttra

le [m

/s2 ]

Page 30: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Results of EC8 pseudo-static vs. 2D dynamic (FEM) analyses(from the M. Eng. Thesis of O. Zanoli, Politecnico di Milano)

Bending moment profiles in retaining wall

Eurocode 8: pseudo-static analyses with assigned kh values for r = 1, 2;

Dynamic analyses: average Mmax values over groups of input accelerograms

Ground type B(Both pseudo-static anddynamic FEM analysesperformed withcommercial software FLAC)

-3500

-3000

-2500

-2000

-1500

-1000

-500

02 3 4 5 6 7 8

h (m)

Mom

ento

flet

tent

e m

assi

mo

[kN

m]

Valori massimi dinamici Pseudo-statico r = 1 Pseudo-statico r = 2 Media valori dinamici

-1800

-1600

-1400

-1200

-1000

-800

-600

-400

-200

02 3 4 5 6 7 8

h (m)M

omen

to fl

ette

nte

mas

sim

o [k

Nm

]

amax=0.35g amax=0.25g

r=1

r=1

r=2r=2

dyn

Maximum Mmax values Pseudo-static r =1 Pseudo-static r =2 Average dynamic values

Page 31: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Bending moment profiles in retaining wallEurocode 8: pseudo-static analyses with assigned kh values for r=1, 2;Dynamic analyses: average Mmax values over groups of input accelerograms

Ground type D(Both pseudo-static anddynamic FEM analysesperformed withcommmercial software FLAC)

-5000

-4500

-4000

-3500

-3000

-2500

-2000

-1500

-1000

-500

02 3 4 5 6 7 8

h (m)

Mom

ento

flet

tent

e m

assi

mo

[kN

m]

Valori dinamici massimi Pseudo-statico r = 1 Pseudo-statico r = 2 Media valori dinamici

-3000

-2500

-2000

-1500

-1000

-500

02 3 4 5 6 7 8

h (m)

Mom

ento

flet

tent

e m

assi

mo

[kN

m]

amax =0.35g amax=0.25g

r=2 r=2

r=1r=1dyn

dyn

Results of EC8 pseudo-static vs. 2D dynamic (FEM) analyses(from the M. Eng. Thesis of O. Zanoli, Politecnico di Milano)

Maximum Mmax values Pseudo-static r =1 Pseudo-static r =2 Average dynamic values

Page 32: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Examples of numerical analysesComplexity of wave propagation phenomena in soil – flexible wall systems(other example with amax = 0.15g)

2

1

3

4

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

2.0

0 2 4 6 8 10 12Tempo [s]

Acc

eler

azio

ne [m

/s²]

5

FinalDisplacement

Snapshots of displacementfield at different instants

Nonlinear dynamic analysesperformed with FEM code Gefdyn

180 m

Page 33: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Examples of numerical analysesAcceleration profile showing amplification of soil-wall seismic motion fromdepth to surface (example with amax = = 0.23g)

-0.3-0.2-0.10.00.10.20.3

Amax = 0.279 g, z = 0.00 m

-0.3-0.2-0.10.00.10.20.3

Amax = 0.187 g, z = - 2.53 m

-0.3-0.2-0.10.00.10.20.3

Amax = 0.180 g, z = - 4.30 m

-0.3-0.2-0.10.00.10.20.3

Amax = 0.126 g, z = - 6.96 m

-0.3-0.2-0.10.00.10.20.3

Amax = 0.105 g, z = - 8.42

-0.3-0.2-0.10.00.10.20.3

Amax = 0.120 g, z = - 11.42

-0.3-0.2-0.10.00.10.20.3

Amax = 0.141 g, z = - 13.47

Page 34: Workshop Eurocodes – Background and Applicationseurocodes.jrc.ec.europa.eu/doc/WS2008/EN1998_7_Faccioli.pdf · Workshop Eurocodes – Background and Applications Brussels, ... •Introduction

Ezio Faccioli

Suggested reference:Designers’ Guide to EN 1998-1

and EN 1998-5

Eurocode 8: Design of structuresfor earthquake resistance.

General rules, seismic actions, design rules for buildings, foundations

and retaining structuresMichael N. Fardis, Eduardo Carvalho, Amr Elnashai, Ezio Faccioli, Paolo Pinto

and Andre Plumier.Published by Thomas Telford, UK, 2006