GLOBAL SPECIALIST FOR POWER BUSBARS C a s t R e s i n I n s u l a t e d B u s w a y S y s t e m

Transcript of Works: Review 10 d.d.08/2015 - Scanelec

Page 1: Works: Review 10 d.d.08/2015 - Scanelec

GLOBAL SPECIALIST FOR POWER BUSBARS

Cast Resin Insulated Busway System

Rev

iew

10

d.d.

08/2

015

Corporate Office:222, Okhla Industrial Estate,

New Delhi-110 020, India

Tel.: +91-11-30884912, 30887520-29

Fax: +91-11-26848241, 26847342

email: [email protected]

Works:

Belgium Plant

Scheldeweg 4,

2850, Boom,

Belgium

Tel.: +32-3-880.64.00

Fax.: +32-3-844.4 2.50

email: [email protected]

Sales Office:

Belgium Office:

Scheldeweg 4,

2850, Boom,

Belgium

Tel.: +32-3-880.64.00

Fax.: +32-3-844 .4 2.50

email: [email protected]

UK Office:

Unit 19/20, Horsham Court,

City Business Centre, 6, Brighton Road,

HORSHAM, West Sussex, RH13 5BB,

United Kingdom

Tel.: +44-1-403265767

Fax: +44-1-403254131

email: [email protected]

Netherland Office:

Zwarte Zee 2-6,

3144, DE MAASSLUIS,

The Netherlands

Tel.: +31-1059-16422

Fax: +31-1059-20673

email: [email protected]

Middle East (FZE) Office:

PO Box 124999

Saif Zone Office, X2-13

Sharjah - UAE

Tel.: +971 65579786

Fax: +971 65579786

E-mail: [email protected]

Page 2: Works: Review 10 d.d.08/2015 - Scanelec

Boom-Belgium

The Eta-com group was founded in 1979 and ever since markets a

full range of cast resin insulated busway systems. The concept which

was already in use in the sixties in industrial installations is now in the

third generation form. Due to the typical characteristics, the system

guarantees the integrity of many projects world-wide, providing safe

and maintenance free electrical power supplies in both Low Voltage

and Medium Voltage installations.

C&S Electric Ltd. was founded in 1966 and is amongst the leading

suppliers of electrical equipment in India. It’s wide range of electrical

and electronic products find application in power generation,

distribution, control, protection and final consumption.

C&S employs over 4000 people including 400 engineers, and has 17

state-of-the-art manufacturing plants. It has 22 sales/marketing

offices across India and its products are exported to more than 80

countries. C&S Electric also has joint venture companies with global

leaders.

The Power Busbar Division of C&S founded in 1982 has been

meeting the evolving needs of power generating stations, process

and manufacturing industries, infrastructure establishments,

technology and technological centers and real estate developments

with its complete and fully tested product line of Busduct,

Bustrunking and associated equipment.

With the acquisition of Eta-com in December 2011, the co-operation

between the two companies give birth to a Global Power Busbars

Specialist.

Manufacturing Facilities

2 3

Haridwar - India

Page 3: Works: Review 10 d.d.08/2015 - Scanelec

Boom-Belgium

The Eta-com group was founded in 1979 and ever since markets a

full range of cast resin insulated busway systems. The concept which

was already in use in the sixties in industrial installations is now in the

third generation form. Due to the typical characteristics, the system

guarantees the integrity of many projects world-wide, providing safe

and maintenance free electrical power supplies in both Low Voltage

and Medium Voltage installations.

C&S Electric Ltd. was founded in 1966 and is amongst the leading

suppliers of electrical equipment in India. It’s wide range of electrical

and electronic products find application in power generation,

distribution, control, protection and final consumption.

C&S employs over 4000 people including 400 engineers, and has 17

state-of-the-art manufacturing plants. It has 22 sales/marketing

offices across India and its products are exported to more than 80

countries. C&S Electric also has joint venture companies with global

leaders.

The Power Busbar Division of C&S founded in 1982 has been

meeting the evolving needs of power generating stations, process

and manufacturing industries, infrastructure establishments,

technology and technological centers and real estate developments

with its complete and fully tested product line of Busduct,

Bustrunking and associated equipment.

With the acquisition of Eta-com in December 2011, the co-operation

between the two companies give birth to a Global Power Busbars

Specialist.

Manufacturing Facilities

2 3

Haridwar - India

Page 4: Works: Review 10 d.d.08/2015 - Scanelec

For Medium Voltage

Type Current Rating Voltage Rating

SH - Series Al upto 1500 A 3.6 KV to 7.2 KV

Cu upto 1850 A

PH - Series Al upto 5000 A 3.6 KV to 17.5 KV

Cu upto 6100 A

Other current and voltage ratings on request.

is the leading technology in the world for cast resin insulated busbars in low & medium voltage installations.

This concept is unique as it is based on the direct encapsulation of copper or aluminium conductors with an insulation compound, B.I.M. casting

mix, consisting of epoxy-resin mixed under vacuum. This B.I.M. casting mix has excellent electrical characteristics and high mechanical withstand

with specific physical properties. It is moisture-resistant, fire-resistant and self extinguishing. A flexible fabrication method, universal moulds and an

integrated process controlled mixing technique allow the production of an almost unlimited number of element forms for L.V as for M.V

applications. The prefabricated elements are self-supporting and are interconnected electrically by joining the conductors with 2-sided

compression contacts, ensuring an excess of contact surfaces and a maximum of adjustment. Junctions and element extremities are overcast with

a B.I.M. casting mix resulting in a homogeneous insulation over the full length of the connection.

busbars can be supplied in the following standard types:

For Low Voltage

LA-LB series

Up to 1000 V AC / 1500V DC

Three phase conductors and/or

Protective earth / 50,100,150, 200% neutral

Al-conductors range up to 5200 A

Cu-conductors range up to 6600 A

DC application on request

Other frequencies on request

mechanical resistance

Other Products

n

n

n

n

n

n

n

n

Non-Segregated Phase Busducts (415 to 1100V upto 6500A)

DC Busbar Systems

PTSP Cubicles

Generator Auxiliary Compartments (GAC)

Neutral Grounding Cubicles

Line & Neutral Side Terminal Boxes

Pressurization System for IPB's

Hot Air Blowing Equipment

range covers Isolated Phase Busduct, Segregated Phase Busducts and Non-Segregated Phase Busducts.

C&S is a market leader in India and amongst the major global companies for design, manufacture, erection and commissioning of lsolated Phase

Bus Ducts up to 1000MW power plants.

Today, we have an enviable track record of having associated with 14 Units of 660 MW, 25 Units of 500 MW, 35 Units of 250 MW, 30 Units of 150

MW Thermal Power Stations, Hydro Power Plants and Nuclear Power Plants, besides many Captive/Private Power Projects of capacity less than

100 MW. The largest proportion of power generated in India flows through C&S busducts.

Busduct have been successfully type tested for highest peak current during short circuit test and also for temperature rise test at world

famous laboratories like KEMA-Holland and EDF-France, CPRI-Bhopal & Bangalore and at IIT-Roorkee (For Seismic tests).

4 5

degree of protection explosion proof on request

Isolated Phase Busduct

C&S offers a wide range of natural air cooled Isolated

Phase Busducts with voltage rating of 11kV to 38 kV

having current rating of 100 A to 30,000 A, with the short

circuit current withstand capacity of 312 kA / sec. & 844 kA

peak. These Busducts have applications in all generating

stations from 50 MW & above.

Non-Segregated Phase Busducts

C&S offers a wide range of Non-Segregated Phase

Busducts for Low Voltage applications from 415 V to

1.1 kV up to 6500 A with a maximum Short Circuit Current

withstand capability of 80 kA RMS for 1 sec. and 180 kA

peak. Non-Segregated Phase Busducts are commonly

used in industrial utilities, power plants for interconnection

between switchgear and transformers and also for lower

capacity of generator (viz DG sets)

Segregated Phase Busducts

C&S offers a wide range of Segregated Phase Busducts for

Medium Voltage applications from 3.3 kV to 33 kV upto

5000 A with a maximum Short Circuit Current withstand

capability of 50 kA rms for 3 sec. and 128 kA peak.

Segregated Phase Busducts find applications in power

generating stations and industrial or distribution plants for

lower capacity generator connections, inter-connections

between switchgear and transformers.

Page 5: Works: Review 10 d.d.08/2015 - Scanelec

For Medium Voltage

Type Current Rating Voltage Rating

SH - Series Al upto 1500 A 3.6 KV to 7.2 KV

Cu upto 1850 A

PH - Series Al upto 5000 A 3.6 KV to 17.5 KV

Cu upto 6100 A

Other current and voltage ratings on request.

is the leading technology in the world for cast resin insulated busbars in low & medium voltage installations.

This concept is unique as it is based on the direct encapsulation of copper or aluminium conductors with an insulation compound, B.I.M. casting

mix, consisting of epoxy-resin mixed under vacuum. This B.I.M. casting mix has excellent electrical characteristics and high mechanical withstand

with specific physical properties. It is moisture-resistant, fire-resistant and self extinguishing. A flexible fabrication method, universal moulds and an

integrated process controlled mixing technique allow the production of an almost unlimited number of element forms for L.V as for M.V

applications. The prefabricated elements are self-supporting and are interconnected electrically by joining the conductors with 2-sided

compression contacts, ensuring an excess of contact surfaces and a maximum of adjustment. Junctions and element extremities are overcast with

a B.I.M. casting mix resulting in a homogeneous insulation over the full length of the connection.

busbars can be supplied in the following standard types:

For Low Voltage

LA-LB series

Up to 1000 V AC / 1500V DC

Three phase conductors and/or

Protective earth / 50,100,150, 200% neutral

Al-conductors range up to 5200 A

Cu-conductors range up to 6600 A

DC application on request

Other frequencies on request

mechanical resistance

Other Products

n

n

n

n

n

n

n

n

Non-Segregated Phase Busducts (415 to 1100V upto 6500A)

DC Busbar Systems

PTSP Cubicles

Generator Auxiliary Compartments (GAC)

Neutral Grounding Cubicles

Line & Neutral Side Terminal Boxes

Pressurization System for IPB's

Hot Air Blowing Equipment

range covers Isolated Phase Busduct, Segregated Phase Busducts and Non-Segregated Phase Busducts.

C&S is a market leader in India and amongst the major global companies for design, manufacture, erection and commissioning of lsolated Phase

Bus Ducts up to 1000MW power plants.

Today, we have an enviable track record of having associated with 14 Units of 660 MW, 25 Units of 500 MW, 35 Units of 250 MW, 30 Units of 150

MW Thermal Power Stations, Hydro Power Plants and Nuclear Power Plants, besides many Captive/Private Power Projects of capacity less than

100 MW. The largest proportion of power generated in India flows through C&S busducts.

Busduct have been successfully type tested for highest peak current during short circuit test and also for temperature rise test at world

famous laboratories like KEMA-Holland and EDF-France, CPRI-Bhopal & Bangalore and at IIT-Roorkee (For Seismic tests).

4 5

degree of protection explosion proof on request

Isolated Phase Busduct

C&S offers a wide range of natural air cooled Isolated

Phase Busducts with voltage rating of 11kV to 38 kV

having current rating of 100 A to 30,000 A, with the short

circuit current withstand capacity of 312 kA / sec. & 844 kA

peak. These Busducts have applications in all generating

stations from 50 MW & above.

Non-Segregated Phase Busducts

C&S offers a wide range of Non-Segregated Phase

Busducts for Low Voltage applications from 415 V to

1.1 kV up to 6500 A with a maximum Short Circuit Current

withstand capability of 80 kA RMS for 1 sec. and 180 kA

peak. Non-Segregated Phase Busducts are commonly

used in industrial utilities, power plants for interconnection

between switchgear and transformers and also for lower

capacity of generator (viz DG sets)

Segregated Phase Busducts

C&S offers a wide range of Segregated Phase Busducts for

Medium Voltage applications from 3.3 kV to 33 kV upto

5000 A with a maximum Short Circuit Current withstand

capability of 50 kA rms for 3 sec. and 128 kA peak.

Segregated Phase Busducts find applications in power

generating stations and industrial or distribution plants for

lower capacity generator connections, inter-connections

between switchgear and transformers.

Page 6: Works: Review 10 d.d.08/2015 - Scanelec

CAST-RESIN INSULATEDBUSWAY SYSTEMS

range cover Sandwich Bustrunking, Air Insulated Bustrunking & Lighting Trunking.

Energy Saver: Bustrunking has lower impedance in comparison to cable and conventional busducts for the same application. Lower impedance

means less energy lost during distribution and this translates into cost savings.

Flexible Distribution: Plug-in type arrangement at regular intervals or as per customer design provides efficient power distribution.

Less Space: Bustrunking system require less space for Installation in a building / industry as compared to conventional busduct and cable system,

so optimum utilization of space.

Conserves Raw-materials & Produces less waste: Material and manpower used in busway is lower than cable & conventional busduct. It saves

money on raw materials and create less waste by buying pre-engineered lengths of busway.

Reusable: Bustrunking system comes with provision of expansions, changes, replacement and reusing.

EB - Sandwich Type

Compliance of Standard IEC 61439 (1&6)

Independent Certificate Authority UL, ASTA, CPRI-India

Conductor Material & Ratings Copper 800A ~ 5000A

Rate Operational Voltage (Ue) 1000 Volt, AC

Rated Impulse Withstand Voltate (Uimp) 12 KV (1.2/50 s)

Enclosure Material Aluminium

Busbar Insulation Multi layer Class - ‘F’ Insulation

Degree of Protection IP 54/ IP55 /IP65 /IP67

Fire Rating 240Min. (ISO 834) 55

Seismic Compliance Zone -5

Section Jointing Uniblock Joint

Plug - in Box 32~630A

CB-Compact Air Insulated Type

Compliance of Standard IEC 61439 (1&6)

Independent Certification Authority ASTA-UK, CPRI-India

Conductor Material & Ratings Copper 125~2000A, Aluminium 200~1250A

Rated Operational Voltage (Ue) 1000 Volt, AC

Rated Impulse Withstand Voltage (Uimp) 12 KV (1.2/50 s)

Enclosure Material G.I

Busbar Insulator Class-F

Degree of Protection IP 54 /55

Fire Rating 120 Min. (ISO 834)

Seismic Compliance Zone-5

Section Jointing Uniblock Joint

Plug in Box 32 ~ 400A

6

Page 7: Works: Review 10 d.d.08/2015 - Scanelec

CAST-RESIN INSULATEDBUSWAY SYSTEMS

range cover Sandwich Bustrunking, Air Insulated Bustrunking & Lighting Trunking.

Energy Saver: Bustrunking has lower impedance in comparison to cable and conventional busducts for the same application. Lower impedance

means less energy lost during distribution and this translates into cost savings.

Flexible Distribution: Plug-in type arrangement at regular intervals or as per customer design provides efficient power distribution.

Less Space: Bustrunking system require less space for Installation in a building / industry as compared to conventional busduct and cable system,

so optimum utilization of space.

Conserves Raw-materials & Produces less waste: Material and manpower used in busway is lower than cable & conventional busduct. It saves

money on raw materials and create less waste by buying pre-engineered lengths of busway.

Reusable: Bustrunking system comes with provision of expansions, changes, replacement and reusing.

EB - Sandwich Type

Compliance of Standard IEC 61439 (1&6)

Independent Certificate Authority UL, ASTA, CPRI-India

Conductor Material & Ratings Copper 800A ~ 5000A

Rate Operational Voltage (Ue) 1000 Volt, AC

Rated Impulse Withstand Voltate (Uimp) 12 KV (1.2/50 s)

Enclosure Material Aluminium

Busbar Insulation Multi layer Class - ‘F’ Insulation

Degree of Protection IP 54/ IP55 /IP65 /IP67

Fire Rating 240Min. (ISO 834) 55

Seismic Compliance Zone -5

Section Jointing Uniblock Joint

Plug - in Box 32~630A

CB-Compact Air Insulated Type

Compliance of Standard IEC 61439 (1&6)

Independent Certification Authority ASTA-UK, CPRI-India

Conductor Material & Ratings Copper 125~2000A, Aluminium 200~1250A

Rated Operational Voltage (Ue) 1000 Volt, AC

Rated Impulse Withstand Voltage (Uimp) 12 KV (1.2/50 s)

Enclosure Material G.I

Busbar Insulator Class-F

Degree of Protection IP 54 /55

Fire Rating 120 Min. (ISO 834)

Seismic Compliance Zone-5

Section Jointing Uniblock Joint

Plug in Box 32 ~ 400A

6

Page 8: Works: Review 10 d.d.08/2015 - Scanelec

busbars are suitable for application in large

buildings, industrial plants, power stations, sub-stations and

large switchrooms, such as:

Factory distribution of low and medium voltage power.

Rising mains with tap-offs to sub-distribution boards in

high rise buildings.

Transformer switchboard connections.

Main switchboard feeders to distribution panels.

Generator and large motor feeders.

400 Hz distribution systems.

Refineries, offshore and onshore platforms.

Zone 2 & Zone 3 Explosive areas.

For special Application, contact our agent.

busway system is available in a wide range of

standard element shapes, forms, and lengths which are

fabricated to suit the typical project requirements. Our

element range consists of :

Straight elements.

Flat and edge elbows.

Z (double elbow) and T elements.

Flanged terminal elements.

Tap-off facilities and phase-transfer elements.

Thermal expansion compensation elements.

Tailor-made terminal elements for transformer or generator

and switchboard connection.

§

§

§

§

§

§

§

§

§

§

§

§

§

§

§

Extensive application and Element Range High-Quality Production

busbars have been developed as a modern, all-

purpose means of efficient and safe transmission of

electrical energy. They have been in manufacture for more

than thirty-five years.

system complies with all the requirements for

current distribution at low and medium voltage.

The busbar consists of copper or aluminium conductors,

embedded in an enclosure of a fire retardant, self

extinguishing and homogeneous insulation mix based on

epoxy cast-resin with mineral fillers, ensuring high

mechanical strength and chemical withstand.

Standard types are available for current ratings up to 6600 A

and voltage ratings up to 17.5kV. Systems for higher

current, high voltage ratings or DC applications are possible

on request.

The busbar line consists of a number of prefabricated

elements. The electrical joining of the conductors is

achieved by means of double fish plates and high tensile

steel bolts.

The junctions and the element ends are overcast with the

same insulation mix as used for the elements. In this way an

integral insulating enclosure to IP68.IK10 is guaranteed

over the full length of the busbar run. Straight junctions and

also elbow junctions are available, each facilitating

installation adjustments of 0-20 mm per standard junction.

8 9

Page 9: Works: Review 10 d.d.08/2015 - Scanelec

busbars are suitable for application in large

buildings, industrial plants, power stations, sub-stations and

large switchrooms, such as:

Factory distribution of low and medium voltage power.

Rising mains with tap-offs to sub-distribution boards in

high rise buildings.

Transformer switchboard connections.

Main switchboard feeders to distribution panels.

Generator and large motor feeders.

400 Hz distribution systems.

Refineries, offshore and onshore platforms.

Zone 2 & Zone 3 Explosive areas.

For special Application, contact our agent.

busway system is available in a wide range of

standard element shapes, forms, and lengths which are

fabricated to suit the typical project requirements. Our

element range consists of :

Straight elements.

Flat and edge elbows.

Z (double elbow) and T elements.

Flanged terminal elements.

Tap-off facilities and phase-transfer elements.

Thermal expansion compensation elements.

Tailor-made terminal elements for transformer or generator

and switchboard connection.

§

§

§

§

§

§

§

§

§

§

§

§

§

§

§

Extensive application and Element Range High-Quality Production

busbars have been developed as a modern, all-

purpose means of efficient and safe transmission of

electrical energy. They have been in manufacture for more

than thirty-five years.

system complies with all the requirements for

current distribution at low and medium voltage.

The busbar consists of copper or aluminium conductors,

embedded in an enclosure of a fire retardant, self

extinguishing and homogeneous insulation mix based on

epoxy cast-resin with mineral fillers, ensuring high

mechanical strength and chemical withstand.

Standard types are available for current ratings up to 6600 A

and voltage ratings up to 17.5kV. Systems for higher

current, high voltage ratings or DC applications are possible

on request.

The busbar line consists of a number of prefabricated

elements. The electrical joining of the conductors is

achieved by means of double fish plates and high tensile

steel bolts.

The junctions and the element ends are overcast with the

same insulation mix as used for the elements. In this way an

integral insulating enclosure to IP68.IK10 is guaranteed

over the full length of the busbar run. Straight junctions and

also elbow junctions are available, each facilitating

installation adjustments of 0-20 mm per standard junction.

8 9

Page 10: Works: Review 10 d.d.08/2015 - Scanelec

Major Advantages

EMCelectro magnetic compatibility

S90 A90fire proof wall bushings

IP68.IK10degree of protection

R Y B N

BY R

N

explosion proof

E30-E120electrical continuity

n Compact Dimensions.

Simple Installation.

Low Voltage Drop and High Short-Circuit withstand Capacity.

Overload Capacity of +20% for 2 Hours.

Degree of Protection of IP68 for L.V bus ways and IP67 for M.V bus ways as per IEC 60529.

High Mechanical Impact strength of IK.10 as per DIN 52453 & IEC 62262.

Fire proof property : Tested for 750°C for 3 Hours in accordance with IEC 60331-21.

Tested for 850°C for 2 Hours in accordance with pre-BS 7346.

Tested as per ISO834-1 for 2 hours in accordance with BS 8602

Fire Wall Bushings of S90 & S120 in accordance with EN1366-3 and NBN 713.020.

Fire Retardant Bushings A90 for Normal fire and H60 for Hydrocarbon Fire In Offshore Applications.

Self-extingusihing insulation as per IEC 60332.

Electrical Continuity E30-E120 finishing available under fire conditions as per DIN 4102-12.

EMC Compatible. (For sensitive environment)

Explosion Proof ATEX, & IEC Ex Certified on request.

Excellent Resistance to atmospheric pollution & wide range of chemicals.

n

n

n

n

n

n

n

n

n

n

n

n

n

Product Certifications

TEST REPORT 2036755.01-QUA/IND Page 1 of 10

Applicant : Eta.comB nv/sa Scheldeweg 4 B-2850 Boom

Application date : 2003-08-29

Order Number : 2036755.00-QUA/IND

Subject : Partially type test of low-voltage busbar turking systems for a maximum rating of 3420 A at a 3-phase voltage of 1000 V (50 Hz)

Trademark : Betobar

Types : LA 3, 4, 5 poles and LB 6, 7, 8, 9 poles

Arnhem, April 6, 2005

Manufacturer/ Production sites:Eta-com B nv/sa, Scheldeweg 4, B-2850 Boom, Belgium

Test Requirements : EC 60439-2:2000

Tested by : H.L. Schendstok

Checked by : H.H.M. Versteegen

Contents- 7 Pages general and description of test reults- 3 pages with drawings

HLS 0173-05

© KEMA Quality B. V. All rights reserved

KEMA Quality B.V. and/or its subsidiaries are not liable for any direct or indirect, incidental or consequential loss originatingthrough or because of the use of the information or date from document or due to the impossibility of using theinformation or data.

The contents of this report may not be made available to a third party other than as an entity provied with theaforementioned designation with respect to copyrights and liability .

Products may only be provided with a quality mark or put on the market as approved if KEMA Quality B.V. has explicitlygranted the right to carry a quality mark.

KEMA Quality B.V., Utrechtseweg 310, 6812 AE Arnhem, The Netherlands, PO Box 5185, 6802 ED Arnhem,The Netherlands. Website www .kema.com www.BuyerRisk.com Telephone: +31 26 3 56 20 00. Telefax: +31 26 3 52 58 00.

MEAN-P-R04engVersion 1.0

TEST REPORT 2071268.01-QUA/IND Page 1 of 3

Applicant : Eta.comB nv/sa Scheldeweg 4 B-2850 Boom

Application date : 2004-02-09

Order Number : 2071268-QUA/IND

Subject: LCW-voltage and medum voltage busbar trunking system

Trademark : Betobar-r

Types : LA, LB, LC, SH, PH and MH (joints and lengths only)

Arnhem, March 31, 2004

Manufacturer/ Production sites:Eta-com B nv/sa, Scheldeweg 4, B-2850 Boom, Belgium

Test Requirements : IEC 60529:2001 Ed. 2. 1

Conclusion: The products comply with the specified requirments.

Tested by : H.L. Schendstok

Checked by : H.H.M. Barends

Enclosure:- 7 Pages general and description of test reults- 3 pages with drawings

HLS/Sco 0373-04

Products may not be provided with one of our approval mark, not put on the market as approved on the bassis of thisreport.

KEMA Quality B.V., Utrechtseweg 310, 6812 AE Arnhem, The Netherlands, Website www .kemaquality.comPO Box 5185, 6802 ED Arnhem,The Netherlands. T elephone: +31 26 3 56 20 00. T elefax: +31 26 3 52 58 00.

© Publication in total or in part and/or reproduction in whatever way of the content of this report is not allowed unlesspermission has been explicitly given either in this trport or by previous letter .

KEMA Quality B.V. and/or its associated companies disclaim liability for any direct, indirect, consequential or incidentaldamages that may result from the use of the information or data, or from the inability to use the information or data.

IPH Type Test Certificate for L. V. Betobar KEMA Type Test Certificate for L. V. Betobar

KEMA Type Test Certificate for Degree of Protection KEMA Type Test Certificate for M. V. Betobar

10 11

Page 11: Works: Review 10 d.d.08/2015 - Scanelec

Major Advantages

EMCelectro magnetic compatibility

S90 A90fire proof wall bushings

IP68.IK10degree of protection

R Y B N

BY R

N

explosion proof

E30-E120electrical continuity

n Compact Dimensions.

Simple Installation.

Low Voltage Drop and High Short-Circuit withstand Capacity.

Overload Capacity of +20% for 2 Hours.

Degree of Protection of IP68 for L.V bus ways and IP67 for M.V bus ways as per IEC 60529.

High Mechanical Impact strength of IK.10 as per DIN 52453 & IEC 62262.

Fire proof property : Tested for 750°C for 3 Hours in accordance with IEC 60331-21.

Tested for 850°C for 2 Hours in accordance with pre-BS 7346.

Tested as per ISO834-1 for 2 hours in accordance with BS 8602

Fire Wall Bushings of S90 & S120 in accordance with EN1366-3 and NBN 713.020.

Fire Retardant Bushings A90 for Normal fire and H60 for Hydrocarbon Fire In Offshore Applications.

Self-extingusihing insulation as per IEC 60332.

Electrical Continuity E30-E120 finishing available under fire conditions as per DIN 4102-12.

EMC Compatible. (For sensitive environment)

Explosion Proof ATEX, & IEC Ex Certified on request.

Excellent Resistance to atmospheric pollution & wide range of chemicals.

n

n

n

n

n

n

n

n

n

n

n

n

n

Product Certifications

TEST REPORT 2036755.01-QUA/IND Page 1 of 10

Applicant : Eta.comB nv/sa Scheldeweg 4 B-2850 Boom

Application date : 2003-08-29

Order Number : 2036755.00-QUA/IND

Subject : Partially type test of low-voltage busbar turking systems for a maximum rating of 3420 A at a 3-phase voltage of 1000 V (50 Hz)

Trademark : Betobar

Types : LA 3, 4, 5 poles and LB 6, 7, 8, 9 poles

Arnhem, April 6, 2005

Manufacturer/ Production sites:Eta-com B nv/sa, Scheldeweg 4, B-2850 Boom, Belgium

Test Requirements : EC 60439-2:2000

Tested by : H.L. Schendstok

Checked by : H.H.M. Versteegen

Contents- 7 Pages general and description of test reults- 3 pages with drawings

HLS 0173-05

© KEMA Quality B. V. All rights reserved

KEMA Quality B.V. and/or its subsidiaries are not liable for any direct or indirect, incidental or consequential loss originatingthrough or because of the use of the information or date from document or due to the impossibility of using theinformation or data.

The contents of this report may not be made available to a third party other than as an entity provied with theaforementioned designation with respect to copyrights and liability .

Products may only be provided with a quality mark or put on the market as approved if KEMA Quality B.V. has explicitlygranted the right to carry a quality mark.

KEMA Quality B.V., Utrechtseweg 310, 6812 AE Arnhem, The Netherlands, PO Box 5185, 6802 ED Arnhem,The Netherlands. Website www .kema.com www.BuyerRisk.com Telephone: +31 26 3 56 20 00. Telefax: +31 26 3 52 58 00.

MEAN-P-R04engVersion 1.0

TEST REPORT 2071268.01-QUA/IND Page 1 of 3

Applicant : Eta.comB nv/sa Scheldeweg 4 B-2850 Boom

Application date : 2004-02-09

Order Number : 2071268-QUA/IND

Subject: LCW-voltage and medum voltage busbar trunking system

Trademark : Betobar-r

Types : LA, LB, LC, SH, PH and MH (joints and lengths only)

Arnhem, March 31, 2004

Manufacturer/ Production sites:Eta-com B nv/sa, Scheldeweg 4, B-2850 Boom, Belgium

Test Requirements : IEC 60529:2001 Ed. 2. 1

Conclusion: The products comply with the specified requirments.

Tested by : H.L. Schendstok

Checked by : H.H.M. Barends

Enclosure:- 7 Pages general and description of test reults- 3 pages with drawings

HLS/Sco 0373-04

Products may not be provided with one of our approval mark, not put on the market as approved on the bassis of thisreport.

KEMA Quality B.V., Utrechtseweg 310, 6812 AE Arnhem, The Netherlands, Website www .kemaquality.comPO Box 5185, 6802 ED Arnhem,The Netherlands. T elephone: +31 26 3 56 20 00. T elefax: +31 26 3 52 58 00.

© Publication in total or in part and/or reproduction in whatever way of the content of this report is not allowed unlesspermission has been explicitly given either in this trport or by previous letter .

KEMA Quality B.V. and/or its associated companies disclaim liability for any direct, indirect, consequential or incidentaldamages that may result from the use of the information or data, or from the inability to use the information or data.

IPH Type Test Certificate for L. V. Betobar KEMA Type Test Certificate for L. V. Betobar

KEMA Type Test Certificate for Degree of Protection KEMA Type Test Certificate for M. V. Betobar

10 11

Page 12: Works: Review 10 d.d.08/2015 - Scanelec

TESTS REPORT Ref: GT 4-3412

Company : Etacom

CONCERNING : Bending tests on aged and reference samples.

Samples type : Bars

Receipt date : 08-09-01

Client reference :

CRIF Reference : 4-3412 Samples conditioning: according to ISO 291 : Temperature (23 _+2) Relative humidty: (50+_5) %

°C

Sampling: realised by the company

Note: Tests results are valid only for materials identical to the tested materials.

Revision 1 Reference 4-34 12etacomrap 102-angl.doc LAB-DT -608 4-3412etacomEstablishment acknowledged by decree of law dated January 30thrd 1947

CRIF , LIEGE science park, Rue du Bois St Jean, 12 B-4102 Seraing (LIEGE) • Tel: 32,4,361,87,00 Fax: 32,4,361,87,02 E-mail: [email protected] de Charleroi, Avenue Georges Lemaitre, 22. B-6041Gosselies (CHARLEROI) • Tel: 32,71,250,362

Registered office and administration :Boulevard A, Reyers 80, B-1030 Bruxelles • Tel:32,2,706,79,44 • G-Bank: 210-0723013-27 • BTW BE 406,606,380

• •

CRIF - WTCMCollective Research Center for Technological Industry

ASTA Type Test Report Ageing Test Report

Flame Spread Test as per IEC 60332 IEC Certification for Explosive Atmospheres

Product Certifications

ATEX Certification for Explosive Areas

Electromagnetic Compatibility

Product Certifications

12 13

32-Diploma notification quality ATEX-rev0

ISO 9001:2008 Certificate

Page 13: Works: Review 10 d.d.08/2015 - Scanelec

TESTS REPORT Ref: GT 4-3412

Company : Etacom

CONCERNING : Bending tests on aged and reference samples.

Samples type : Bars

Receipt date : 08-09-01

Client reference :

CRIF Reference : 4-3412 Samples conditioning: according to ISO 291 : Temperature (23 _+2) Relative humidty: (50+_5) %

°C

Sampling: realised by the company

Note: Tests results are valid only for materials identical to the tested materials.

Revision 1 Reference 4-34 12etacomrap 102-angl.doc LAB-DT -608 4-3412etacomEstablishment acknowledged by decree of law dated January 30thrd 1947

CRIF , LIEGE science park, Rue du Bois St Jean, 12 B-4102 Seraing (LIEGE) • Tel: 32,4,361,87,00 Fax: 32,4,361,87,02 E-mail: [email protected] de Charleroi, Avenue Georges Lemaitre, 22. B-6041Gosselies (CHARLEROI) • Tel: 32,71,250,362

Registered office and administration :Boulevard A, Reyers 80, B-1030 Bruxelles • Tel:32,2,706,79,44 • G-Bank: 210-0723013-27 • BTW BE 406,606,380

• •

CRIF - WTCMCollective Research Center for Technological Industry

ASTA Type Test Report Ageing Test Report

Flame Spread Test as per IEC 60332 IEC Certification for Explosive Atmospheres

Product Certifications

ATEX Certification for Explosive Areas

Electromagnetic Compatibility

Product Certifications

12 13

32-Diploma notification quality ATEX-rev0

ISO 9001:2008 Certificate

Page 14: Works: Review 10 d.d.08/2015 - Scanelec

Type Test Report for MV Betobar Type Test Report for LV Betobar

Type Test Report for MV Betobar Type Test Report for LV Betobar

Product Certification

14

Low Voltage

Page 15: Works: Review 10 d.d.08/2015 - Scanelec

30

Medium VoltageBusway Route Planner

Customer : Date :

Information required for quotation. Please, photocopy this form and attach to your inquiry.

In Un Freq.

A V Hz

Conductors

Temp.

3P N PE + -

t00C 0C

tmax

Project :

Job nr :

Cu Al

Line

nr

Lengthtotal

m

Outdoor Tap off’sIn

m nr

Page 16: Works: Review 10 d.d.08/2015 - Scanelec

Technical Specifications for Medium Voltage

Compliance Standard IEC 62271 (1 & 201)

Independent Certification Authority KEMA, MPA (Germany), ISSeP, ASTA, IPH, CPRI (India)

Type of Series SH & PH Series

Ratings SH Series

Aluminium - 1350A to 1500A

Copper - 1300A to 1850A

PH Series

Aluminium - 1350A to 5000A

Copper - 1750A to 6100A

Rated Operating Voltage SH Series - 3.6 kV to 7.2 kV

PH Series - 3.6 kV to 17.5 kV

Rated Frequency 50Hz/60Hz

Busbar Material Copper 99.9% Pure ETP grade

Aluminium, 99.5% Pure grade

Degree of Protection IP66/67 as per IEC 60529

Mechanical Impact IK.10 as per IEC 62262 DIN 52453

Conditions of use Altitude upto 5000m, indoor as well as outdoor0 0Ambient temperature: -50 C / + 60 C

Ambient Humidity : 0% - 100%

Applications

32 33

Page 17: Works: Review 10 d.d.08/2015 - Scanelec

Technical Specifications for Medium Voltage

Compliance Standard IEC 62271 (1 & 201)

Independent Certification Authority KEMA, MPA (Germany), ISSeP, ASTA, IPH, CPRI (India)

Type of Series SH & PH Series

Ratings SH Series

Aluminium - 1350A to 1500A

Copper - 1300A to 1850A

PH Series

Aluminium - 1350A to 5000A

Copper - 1750A to 6100A

Rated Operating Voltage SH Series - 3.6 kV to 7.2 kV

PH Series - 3.6 kV to 17.5 kV

Rated Frequency 50Hz/60Hz

Busbar Material Copper 99.9% Pure ETP grade

Aluminium, 99.5% Pure grade

Degree of Protection IP66/67 as per IEC 60529

Mechanical Impact IK.10 as per IEC 62262 DIN 52453

Conditions of use Altitude upto 5000m, indoor as well as outdoor0 0Ambient temperature: -50 C / + 60 C

Ambient Humidity : 0% - 100%

Applications

32 33

Page 18: Works: Review 10 d.d.08/2015 - Scanelec

SH Series SH Series - Element Restricted Dimensions

Straight Element

RE1

RE2

RE3

RE4

REL1 (mm)

Norm Min Max

350

1001

2001

3001

1000

2000

3000

4000

1000

2000

3000

4000

Brazed Elbow Element

Bent Elbow Element

HLL1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L-Total

2000

1000

2000

1000HL1

HL2

SH06

SH10

SH06

SH10

260

280

740

720

1740

1720

500

500

260

280

260

280

520

560500

1500 1001401

600

600

Brazed 'Z' Element

L Total

Norm Min Max ZL

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000565

605

1001 2000

1000ZL1

ZL2

SH06

SH10

SH06

SH10

260

280

260

280

695

675

1695

1675

440

420

1240

1220

560

520

560

520

300

500

45260

280

260

28045

HBL1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L-Total

2000

1000

2000

1000HB1

HB2

SH06

SH10

SH06

SH10

290

290

290

290

710

710

1710

1710

710

710

1710

1710

500

500

290

290

290

290

580

580500

500 1001

*Total average weight of the system with junctions and standard supports.

34 35

*Depending on the geometry of termination head flange.

Aluminium

Copper

480 60 x 8 1300 45 113 37 48 103 114 245 43SH 06C 160 x 100 250 x 155

600 60 x 10 1450 60 150 29 40 101 109 251 46

800 100 x 8 1700 50 125 22 31 79 85 268 63SH 10C 160 x 140 250 x 195

1000 100 x 10 1850 65 163 18 26 78 82 263 67

B x H (mm)

Type B’ x H’ (mm)

CrossSection Area

2mm

BusbarSizemm

In(A)

Ip(kA)

Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)

Element Weight *Kg/m

SH Series - Aluminium Betobar, 3.6 - 7.2KV

Icw(kA)

H

H’

B’

B’

R S T

800 100 x 8 1350 35 88 36 49 79 93 266 48SH 10A 160 x 140 250 x 195

1000 100 x 10 1500 45 113 29 40 78 87 268 48

B x H (mm)

Type B’ x H’ (mm)

CrossSection Area

2mm

BusbarSizemm

Element Weight *Kg/m

SH Series - Aluminium Betobar, 3.6 - 7.2KV

In(A)

Ip(kA)

Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)

Icw(kA)

Page 19: Works: Review 10 d.d.08/2015 - Scanelec

SH Series SH Series - Element Restricted Dimensions

Straight Element

RE1

RE2

RE3

RE4

REL1 (mm)

Norm Min Max

350

1001

2001

3001

1000

2000

3000

4000

1000

2000

3000

4000

Brazed Elbow Element

Bent Elbow Element

HLL1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L-Total

2000

1000

2000

1000HL1

HL2

SH06

SH10

SH06

SH10

260

280

740

720

1740

1720

500

500

260

280

260

280

520

560500

1500 1001401

600

600

Brazed 'Z' Element

L Total

Norm Min Max ZL

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000565

605

1001 2000

1000ZL1

ZL2

SH06

SH10

SH06

SH10

260

280

260

280

695

675

1695

1675

440

420

1240

1220

560

520

560

520

300

500

45260

280

260

28045

HBL1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L-Total

2000

1000

2000

1000HB1

HB2

SH06

SH10

SH06

SH10

290

290

290

290

710

710

1710

1710

710

710

1710

1710

500

500

290

290

290

290

580

580500

500 1001

*Total average weight of the system with junctions and standard supports.

34 35

*Depending on the geometry of termination head flange.

Aluminium

Copper

480 60 x 8 1300 45 113 37 48 103 114 245 43SH 06C 160 x 100 250 x 155

600 60 x 10 1450 60 150 29 40 101 109 251 46

800 100 x 8 1700 50 125 22 31 79 85 268 63SH 10C 160 x 140 250 x 195

1000 100 x 10 1850 65 163 18 26 78 82 263 67

B x H (mm)

Type B’ x H’ (mm)

CrossSection Area

2mm

BusbarSizemm

In(A)

Ip(kA)

Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)

Element Weight *Kg/m

SH Series - Aluminium Betobar, 3.6 - 7.2KV

Icw(kA)

H

H’

B’

B’

R S T

800 100 x 8 1350 35 88 36 49 79 93 266 48SH 10A 160 x 140 250 x 195

1000 100 x 10 1500 45 113 29 40 78 87 268 48

B x H (mm)

Type B’ x H’ (mm)

CrossSection Area

2mm

BusbarSizemm

Element Weight *Kg/m

SH Series - Aluminium Betobar, 3.6 - 7.2KV

In(A)

Ip(kA)

Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)

Icw(kA)

Page 20: Works: Review 10 d.d.08/2015 - Scanelec

36 37

AE1

AE2

L1

Norm Min Max

400*

1001

1000

2000

500

1500

AP1

AP2

L1

Norm Min Max

400*

1001

1000

2000

500

1500

AC1

AC2

L1

Norm Min Max

400*

1001

1000

2000

500

1500

Terminal Elements

‘AE’ Type

‘AP’ Type

‘AC’ Type

Bent ‘Z’ Element

Brazed ‘T’ Element

Bent ‘T’ Element

Expansion Element

EX1

EXL1 (mm)

Norm Min Max

1000 10001000

L Total

Norm Min Max ZB

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000680

680

1001 2000

1000ZB1

ZB2

SH06

SH10

SH06

SH10

290

290

290

290

610

610

1610

1610

350

1000

420

420

1420

1420

300

500

100290

290

290

290100

350

500

610

610

1610

1610

L Total

Norm Min Max TB

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

1235

1455TB2

SH06

SH10

460

570315

460

570

L Total

Norm Min Max TL

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000780

840

1001 2000

1000TL1

TL2

SH06

SH10

SH06

SH10

260

280

260

280

480

440

1480

1440

330

500

480

440

1480

1440

330

500

260

280

260

280

340

500

480

440

1480

1440

260

280

260

280

‘XL’ Type‘XR’ Type

Double Elbow Element

L Total

Norm Min Max XR/XL

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000840

860

1001 2000

1000XR1/XL1

SH06

SH10

SH06

SH10

290

290

290

290

450

430

1450

1430

330

500

450

430

1450

1430

330

1000

260

280

260

280

340

500

420

420

290

290

290

290

XR2/XL2

600

Page 21: Works: Review 10 d.d.08/2015 - Scanelec

36 37

AE1

AE2

L1

Norm Min Max

400*

1001

1000

2000

500

1500

AP1

AP2

L1

Norm Min Max

400*

1001

1000

2000

500

1500

AC1

AC2

L1

Norm Min Max

400*

1001

1000

2000

500

1500

Terminal Elements

‘AE’ Type

‘AP’ Type

‘AC’ Type

Bent ‘Z’ Element

Brazed ‘T’ Element

Bent ‘T’ Element

Expansion Element

EX1

EXL1 (mm)

Norm Min Max

1000 10001000

L Total

Norm Min Max ZB

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000680

680

1001 2000

1000ZB1

ZB2

SH06

SH10

SH06

SH10

290

290

290

290

610

610

1610

1610

350

1000

420

420

1420

1420

300

500

100290

290

290

290100

350

500

610

610

1610

1610

L Total

Norm Min Max TB

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

1235

1455TB2

SH06

SH10

460

570315

460

570

L Total

Norm Min Max TL

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000780

840

1001 2000

1000TL1

TL2

SH06

SH10

SH06

SH10

260

280

260

280

480

440

1480

1440

330

500

480

440

1480

1440

330

500

260

280

260

280

340

500

480

440

1480

1440

260

280

260

280

‘XL’ Type‘XR’ Type

Double Elbow Element

L Total

Norm Min Max XR/XL

L1 (mm)

Norm Min Max Norm Min Max Norm Min Max

L2 L3

2000

1000840

860

1001 2000

1000XR1/XL1

SH06

SH10

SH06

SH10

290

290

290

290

450

430

1450

1430

330

500

450

430

1450

1430

330

1000

260

280

260

280

340

500

420

420

290

290

290

290

XR2/XL2

600

Page 22: Works: Review 10 d.d.08/2015 - Scanelec

*P2 dimension will be as per the equipment

layout depending on the geometry of the terminal head.

PH Series

38 39

Terminal Elements

L1

Norm Min Max

AG1 400* 1000500

L1

Norm Min Max

AO1 400* 1000500

L1

Norm Min Max

AJ1 400* 1000500

L1

Norm Min Max

AM1 400* 1000500

‘AG’ Type

‘AO’ Type

‘AJ’ Type

‘AM’ Type

L1

Norm Min Max

AH1 400* 1000500

‘AH’ Type

Note: Derating of various shielding will be given by agent.

Aluminium

Electrical Parameters

480 80 x 6 1350 35 88 60 78 142 162 428PH 08A

640 80 x 8 1550 45 113 45 60 140 152 429

PH 12A 720 120 x 6 1650 50 125 40 54 120 131 437

960 160 x 6 2250 65 163 30 41 104 112 624PH 16A

1280 160 x 8 2550 90 225 23 32 103 108 622

PH 20A 1600 100 x 8 x 2 3200 110 275 18 26 92 96 808

1920 120 x 8 x 2 3750 120 300 15 22 83 86 948

2400 120 x 10 x 2 4100 120 300 12 19 83 85 941PH 24A

2880 120 x 12 x 2 4450 120 300 10 16 82 84 953

3840 120 x 16 x 2 5000 120 300 8 13 82 82 953

Type Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)

PH Series - Unshielded Aluminium Betobar, 3.6-7.2-12-17.5KV

In(A)

Ip(kA)

Busbar Size (mm)

Cross Section

2Area (mm )

Icw(kA)

480 80 x 6 1750 50 125 36 49 142 150 447PH 08C

640 80 x 8 2000 65 163 27 38 140 145 451

PH 12C 720 120 x 6 2100 75 188 24 34 120 124 447

960 160 x 6 2800 75 188 18 26 104 107 619PH 16C

1280 160 x 8 3200 95 238 14 21 103 105 633

PH 20C 1600 100 x 8 x 2 4000 120 300 11 17 92 94 821

1920 120 x 8 x 2 4650 120 300 9 15 83 84 952

2400 120 x 10 x 2 5100 120 300 7 12 83 84 958PH 24C

2880 120 x 12 x 2 5500 120 300 6 11 82 83 961

3840 120 x 16 x 2 6100 120 300 5 9 82 82 949

Type

PH Series - Unshielded Copper Betobar, 3.6 - 7.2 - 12 - 17.5KV

In(A)

Busbar Size (mm)

Cross Section

2Area (mm )

Copper

Electrical Parameters

Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)Ip(kA)

Icw(kA)

Page 23: Works: Review 10 d.d.08/2015 - Scanelec

*P2 dimension will be as per the equipment

layout depending on the geometry of the terminal head.

PH Series

38 39

Terminal Elements

L1

Norm Min Max

AG1 400* 1000500

L1

Norm Min Max

AO1 400* 1000500

L1

Norm Min Max

AJ1 400* 1000500

L1

Norm Min Max

AM1 400* 1000500

‘AG’ Type

‘AO’ Type

‘AJ’ Type

‘AM’ Type

L1

Norm Min Max

AH1 400* 1000500

‘AH’ Type

Note: Derating of various shielding will be given by agent.

Aluminium

Electrical Parameters

480 80 x 6 1350 35 88 60 78 142 162 428PH 08A

640 80 x 8 1550 45 113 45 60 140 152 429

PH 12A 720 120 x 6 1650 50 125 40 54 120 131 437

960 160 x 6 2250 65 163 30 41 104 112 624PH 16A

1280 160 x 8 2550 90 225 23 32 103 108 622

PH 20A 1600 100 x 8 x 2 3200 110 275 18 26 92 96 808

1920 120 x 8 x 2 3750 120 300 15 22 83 86 948

2400 120 x 10 x 2 4100 120 300 12 19 83 85 941PH 24A

2880 120 x 12 x 2 4450 120 300 10 16 82 84 953

3840 120 x 16 x 2 5000 120 300 8 13 82 82 953

Type Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)

PH Series - Unshielded Aluminium Betobar, 3.6-7.2-12-17.5KV

In(A)

Ip(kA)

Busbar Size (mm)

Cross Section

2Area (mm )

Icw(kA)

480 80 x 6 1750 50 125 36 49 142 150 447PH 08C

640 80 x 8 2000 65 163 27 38 140 145 451

PH 12C 720 120 x 6 2100 75 188 24 34 120 124 447

960 160 x 6 2800 75 188 18 26 104 107 619PH 16C

1280 160 x 8 3200 95 238 14 21 103 105 633

PH 20C 1600 100 x 8 x 2 4000 120 300 11 17 92 94 821

1920 120 x 8 x 2 4650 120 300 9 15 83 84 952

2400 120 x 10 x 2 5100 120 300 7 12 83 84 958PH 24C

2880 120 x 12 x 2 5500 120 300 6 11 82 83 961

3840 120 x 16 x 2 6100 120 300 5 9 82 82 949

Type

PH Series - Unshielded Copper Betobar, 3.6 - 7.2 - 12 - 17.5KV

In(A)

Busbar Size (mm)

Cross Section

2Area (mm )

Copper

Electrical Parameters

Rdc o20 C

µ /mW

Racµ /mW

Xµ /mW

Zµ /mW

P (W/m)Ip(kA)

Icw(kA)

Page 24: Works: Review 10 d.d.08/2015 - Scanelec

40 41

Straight Element

Brazed Elbow Element

REL1 (mm)

Norm

1000

2000

3000

4000

Min

550

1001

2001

3001

Max

1000

2000

3000

4000

RE1

RE2

RE3

RE4

PH Series - Elements

HL

HL1

PH10

PH12

PH16

PH20

PH24

PH10

PH12

PH16

PH20

PH24

650

595

575

550

530

1650

1595

1575

1550

1530

360

375

395

420

440

651

596

576

551

531

350

405

425

450

470

350

405

425

450

470

2000

1000

L1

Norm Min Max Norm Min Max Norm

710

780

820

870

910

1001

Min

2000

1000

Norm

L2 L Total

1000

2000

* Total average weight of the system with junctions and standard supports

Note: For derating of various shielding configurations, please consult Eta-com or your agent.

Additional Configuration

Shielded with Sun-Roof

480 71 61PH 08C PH 08A 322 x 130 390 x 205

640 75 61

PH 12C PH 12A 720 322 x 170 390 x 245 95 79

960 118 98PH 16C PH 16A 322 x 210 390 x 285

1280 126 99

PH 20C PH 20A 1600 322 x 260 390 x 335 145 120

1920 168 138

2400 191 140PH 24C PH 24A 322 x 300 390 x 375

2880 203 141

3840 226 144

Type Element Weight(kg)/m

PH Series - Unshielded Betobar, 3.6 - 7.2 - 12 - 17.5kV

B x Hmm

B’ x H’mm

Dimension Details

Copper Aluminium Copper Aluminium

480 86 76PH 08CS PH 08AS 322 x 130 518 x 378

640 90 76

PH 12CS PH 12AS 720 322 x 170 522 x 418 114 98

960 139 118PH 16CS PH 16AS 322 x 210 522 x 458

1280 147 119

PH 20CS PH 20AS 1600 322 x 260 522 x 508 168 143

1920 196 166

2400 219 167PH 24CS PH 24AS 322 x 300 542 x 560

2880 231 169

3840 254 172

Type Element Weight(kg)/m

PH Series - Shielded Betobar, 3.6 - 7.2 - 12 - 17.5kV

B x Hmm

B’ x H’mm

Copper Aluminium Copper Aluminium

Cross Section

2Area (mm )

Cross Section

2Area (mm )

H”

H

BB”

B

R S T

B’

H’

H

BB’

H’

H

Half Shielded

HH’

B

B’

Page 25: Works: Review 10 d.d.08/2015 - Scanelec

40 41

Straight Element

Brazed Elbow Element

REL1 (mm)

Norm

1000

2000

3000

4000

Min

550

1001

2001

3001

Max

1000

2000

3000

4000

RE1

RE2

RE3

RE4

PH Series - Elements

HL

HL1

PH10

PH12

PH16

PH20

PH24

PH10

PH12

PH16

PH20

PH24

650

595

575

550

530

1650

1595

1575

1550

1530

360

375

395

420

440

651

596

576

551

531

350

405

425

450

470

350

405

425

450

470

2000

1000

L1

Norm Min Max Norm Min Max Norm

710

780

820

870

910

1001

Min

2000

1000

Norm

L2 L Total

1000

2000

* Total average weight of the system with junctions and standard supports

Note: For derating of various shielding configurations, please consult Eta-com or your agent.

Additional Configuration

Shielded with Sun-Roof

480 71 61PH 08C PH 08A 322 x 130 390 x 205

640 75 61

PH 12C PH 12A 720 322 x 170 390 x 245 95 79

960 118 98PH 16C PH 16A 322 x 210 390 x 285

1280 126 99

PH 20C PH 20A 1600 322 x 260 390 x 335 145 120

1920 168 138

2400 191 140PH 24C PH 24A 322 x 300 390 x 375

2880 203 141

3840 226 144

Type Element Weight(kg)/m

PH Series - Unshielded Betobar, 3.6 - 7.2 - 12 - 17.5kV

B x Hmm

B’ x H’mm

Dimension Details

Copper Aluminium Copper Aluminium

480 86 76PH 08CS PH 08AS 322 x 130 518 x 378

640 90 76

PH 12CS PH 12AS 720 322 x 170 522 x 418 114 98

960 139 118PH 16CS PH 16AS 322 x 210 522 x 458

1280 147 119

PH 20CS PH 20AS 1600 322 x 260 522 x 508 168 143

1920 196 166

2400 219 167PH 24CS PH 24AS 322 x 300 542 x 560

2880 231 169

3840 254 172

Type Element Weight(kg)/m

PH Series - Shielded Betobar, 3.6 - 7.2 - 12 - 17.5kV

B x Hmm

B’ x H’mm

Copper Aluminium Copper Aluminium

Cross Section

2Area (mm )

Cross Section

2Area (mm )

H”

H

BB”

B

R S T

B’

H’

H

BB’

H’

H

Half Shielded

HH’

B

B’

Page 26: Works: Review 10 d.d.08/2015 - Scanelec

Bent Elbow Element

500

500

HB

HB1

HB2 2000

1000

L1

Norm Min Max Norm Min Max Norm

740

760

760

760

760

1001

Min

2000

1000

Norm

L2 L Total

630

620

620

620

620

1630

1620

1620

1620

1620

370

380

380

380

380

370

380

380

380

380

630

620

620

620

620

1630

1620

1620

1620

1620

370

380

380

380

380

370

380

380

380

380

500

1500

PH10

PH12

PH16

PH20

PH24

PH10

PH12

PH16

PH20

PH24

Bent 'Z' Element

370

380

380

380

380

370

380

380

380

380

ZB1

ZB2

200

500

ZB

500

400

L1

Norm Min Max Norm Max Norm Min Norm

L2 L 3

260

240

240

240

240

1260

1240

1240

1240

1240

Min

400

1000

PH10

PH12

PH16

PH20

PH24

PH10

PH12

PH16

PH20

PH24

370

380

380

380

380

370

380

380

380

380

430

575

575

575

575

1430

1575

1575

1575

1575

Norm Min Norm

200

45

45

45

45

200

45

45

45

45

L Total

1000 1000

430

575

575

575

575

1430

1575

1575

1575

1575

2000 1001 2000

940

805

805

805

805

42 43

Brazed ‘T’ Element

Double Elbow Element

Expansion Element

L1 (mm)

Norm Min Max

1000

EX

EX1 1000 1000

350

405

425

450

470

XR2/XL2

500

XR / XLL1

Norm Min Max Norm Max Norm Min Max

L2 L 3

1280

1215

1195

1170

1150

Min

650

595

575

550

530

PH10

PH12

PH16

PH20

PH24

370

380

380

380

380

1339

1259

1219

1169

1129

Norm Min Max

311

336

356

381

401

L Total

2000

1031

1121

1161

1211

1251

1500

350

405

425

450

470

TL2 500

TLL1

Norm Min Max Norm Max Norm Min Max

L2 L 3

1290

1220

1180

1130

1090

Min

PH10

PH12

PH16

PH20

PH24

360

375

395

420

440

1290

1220

1180

1130

1090

Norm Min Max

360

375

395

420

440

L Total

1500 2000

1070

1155

1215

1290

1350

650

595

575

550

530

‘XR’ Element ‘XL’ Element

Page 27: Works: Review 10 d.d.08/2015 - Scanelec

Bent Elbow Element

500

500

HB

HB1

HB2 2000

1000

L1

Norm Min Max Norm Min Max Norm

740

760

760

760

760

1001

Min

2000

1000

Norm

L2 L Total

630

620

620

620

620

1630

1620

1620

1620

1620

370

380

380

380

380

370

380

380

380

380

630

620

620

620

620

1630

1620

1620

1620

1620

370

380

380

380

380

370

380

380

380

380

500

1500

PH10

PH12

PH16

PH20

PH24

PH10

PH12

PH16

PH20

PH24

Bent 'Z' Element

370

380

380

380

380

370

380

380

380

380

ZB1

ZB2

200

500

ZB

500

400

L1

Norm Min Max Norm Max Norm Min Norm

L2 L 3

260

240

240

240

240

1260

1240

1240

1240

1240

Min

400

1000

PH10

PH12

PH16

PH20

PH24

PH10

PH12

PH16

PH20

PH24

370

380

380

380

380

370

380

380

380

380

430

575

575

575

575

1430

1575

1575

1575

1575

Norm Min Norm

200

45

45

45

45

200

45

45

45

45

L Total

1000 1000

430

575

575

575

575

1430

1575

1575

1575

1575

2000 1001 2000

940

805

805

805

805

42 43

Brazed ‘T’ Element

Double Elbow Element

Expansion Element

L1 (mm)

Norm Min Max

1000

EX

EX1 1000 1000

350

405

425

450

470

XR2/XL2

500

XR / XLL1

Norm Min Max Norm Max Norm Min Max

L2 L 3

1280

1215

1195

1170

1150

Min

650

595

575

550

530

PH10

PH12

PH16

PH20

PH24

370

380

380

380

380

1339

1259

1219

1169

1129

Norm Min Max

311

336

356

381

401

L Total

2000

1031

1121

1161

1211

1251

1500

350

405

425

450

470

TL2 500

TLL1

Norm Min Max Norm Max Norm Min Max

L2 L 3

1290

1220

1180

1130

1090

Min

PH10

PH12

PH16

PH20

PH24

360

375

395

420

440

1290

1220

1180

1130

1090

Norm Min Max

360

375

395

420

440

L Total

1500 2000

1070

1155

1215

1290

1350

650

595

575

550

530

‘XR’ Element ‘XL’ Element

Page 28: Works: Review 10 d.d.08/2015 - Scanelec

Terminal Elements

‘AC’ Type ‘AC’ (Shielding)Type

L1

Norm Min Max

500AC1 500 1000

1500AC2 1001 2000

‘AE’ Type ‘AE’ (Shielding)Type

L1

Norm Min Max

500AE1 500 1000

1500AE2 1001 2000

‘AG’ Type ‘AG’ (Shielding)Type

AG1

L1

Norm Min Max

450 1000500

‘AM’ Type ‘AM’ (Shielding) Type

‘AO’ Type ‘AO’ (Shielding)Type

‘AJ’ Type ‘AJ’ (Shielding)Type

AJ1

L1

Norm Min Max

450 1000500

AM1

L1

Norm Min Max

450 1000500

AO1

L1

Norm Min Max

450 1000500

44 45

*P2 dimension will be as per the equipment

layout depending on the geometry of the terminal head.

*P2 dimension will be as per the equipment

layout depending on the geometry of the terminal head.

Page 29: Works: Review 10 d.d.08/2015 - Scanelec

Terminal Elements

‘AC’ Type ‘AC’ (Shielding)Type

L1

Norm Min Max

500AC1 500 1000

1500AC2 1001 2000

‘AE’ Type ‘AE’ (Shielding)Type

L1

Norm Min Max

500AE1 500 1000

1500AE2 1001 2000

‘AG’ Type ‘AG’ (Shielding)Type

AG1

L1

Norm Min Max

450 1000500

‘AM’ Type ‘AM’ (Shielding) Type

‘AO’ Type ‘AO’ (Shielding)Type

‘AJ’ Type ‘AJ’ (Shielding)Type

AJ1

L1

Norm Min Max

450 1000500

AM1

L1

Norm Min Max

450 1000500

AO1

L1

Norm Min Max

450 1000500

44 45

*P2 dimension will be as per the equipment

layout depending on the geometry of the terminal head.

*P2 dimension will be as per the equipment

layout depending on the geometry of the terminal head.

Page 30: Works: Review 10 d.d.08/2015 - Scanelec

46

General InformationJoints for Medium Voltage

ST 26 Joint

ST 27 Joint

ST 28 Joint

ST 29 Joint

n

n

n

Design Fundamentals

Termination Details

Bushings up till S120

n

n

n

Chemical Resistance

Standard Work Tests

Reference Lists

Assemble Cast Result

Page 31: Works: Review 10 d.d.08/2015 - Scanelec
Page 32: Works: Review 10 d.d.08/2015 - Scanelec
Page 33: Works: Review 10 d.d.08/2015 - Scanelec