WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or...

8
STANDARD PANEL DIMENSIONS 26.94 684.4 ERO PANEL DIMENSIONS [26.98] 685.2 STANDARD PANEL DIMENSIONS 47.78 1213.6 ERO PANEL DIMENSIONS [47.81] 1214.4 FRONT VIEW STANDARD PANEL SHOWN TOP VIEW X-ADJUSTMENT ±3mm 3mm HEX KEY Y/ROTATION-ADJUSTMENT ±3mm 3mm HEX KEY TOP CORNER Z-ADJUSTMENT ±3mm 3mm HEX KEY BOTTOM CORNER Z-ADJUSTMENT ±3mm 3mm HEX KEY BOTTOM VIEW 3.32 84.3 NOMINAL WITHOUT MOUNT STANDARD PANEL SHOWN 3.6 90 STANDARD PANEL NOMINAL 3.7 94 ERO PANEL NOMINAL 'A' SEE TABLE WITH MOUNT ERO PANEL SHOWN CEILING DUE TO HOT AIR BUILD UP AT THE TOP OF AN INSTALLED ARRAY, PLANS SHOULD BE MADE TO ALLOW THIS AIR TO ESCAPE EITHER OUT THE FRONT, BACK OR CEILING WHERE SHOWN. 2.31 58.8 9.74 247.5 13° SERVICE MODE WITH MOUNT ELECTRONICS INTERFACE 2X POSITION SENSOR TRANSMITTER POSITION SENSOR RECEIVER HANDLES EASY AXIS MOUNT INTERFACE DO NOT HANDLE THIS AREA SIDE VIEWS REVISION HISTORY ECO ZONE REV. DESCRIPTION DATE APPR'D MINIMUM GAP TO CEILING 'A' CONDITION mm in SERVICE MODE 38 1.5 TOOL ACCESS 165 6.5 PANEL REMOVAL ONLY 32 1.3 MINIMUM GAP 17 0.7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A A B B C C D D THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMS IS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASIS FOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS. TOLERANCES: ENGR BY DRAWN BY CHECKED BY USED ON MATERIAL FINISH EJS EJS 20NOV13 20NOV13 PLANAR SYSTEMS, INC. 1195 NW COMPTON DRIVE BEAVERTON, OR 97006 USA CLARITY MATRIX MX55HDU-L PRODUCT OUTLINE TITLE SIZE D PART NO. - DRAWING NO. UX2 55L Outline- REV 01 SCALE 1:5 DO NOT SCALE SHEET 1 OF 8 050-0218-00 REV B THIRD ANGLE PROJECTION DIMENSIONING AND TOLERANCING PER ASME Y14.5M-1994 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS [INCHES]. = ±1° XX= ±.25 .X= ±.5 X= ±1 2. PANEL TEMPERATURES CAN INCREASE 3-5°C WITH EACH VERTICALLY STACKED UNIT. 1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. NOTES: UNLESS OTHERWISE SPECIFIED.

Transcript of WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or...

Page 1: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

STANDARD PANELDIMENSIONS

26.94684.4

ERO PANELDIMENSIONS

[26.98]685.2

STANDARD PANELDIMENSIONS

47.781213.6

ERO PANELDIMENSIONS

[47.81]1214.4

FRONT VIEWSTANDARD PANEL SHOWN

TOP VIEW

X-ADJUSTMENT ±3mm3mm HEX KEY

Y/ROTATION-ADJUSTMENT ±3mm3mm HEX KEY

TOP CORNERZ-ADJUSTMENT ±3mm3mm HEX KEY

BOTTOM CORNERZ-ADJUSTMENT ±3mm3mm HEX KEY

BOTTOM VIEW

3.3284.3

NOMINAL

WITHOUT MOUNTSTANDARD PANEL SHOWN

3.690

STANDARDPANEL

NOMINAL3.794

ERO PANELNOMINAL

'A' SEE TABLE

WITH MOUNTERO PANEL SHOWN

CEILING

DUE TO HOT AIR BUILD UP AT THETOP OF AN INSTALLED ARRAY,PLANS SHOULD BE MADE TOALLOW THIS AIR TO ESCAPE EITHER OUT THE FRONT, BACK ORCEILING WHERE SHOWN.

2.3158.8

9.74247.5

13°

SERVICE MODE

WITH MOUNT

ELECTRONICSINTERFACE

2X POSITION SENSORTRANSMITTER

POSITION SENSORRECEIVER

HANDLES

EASY AXIS MOUNTINTERFACE

DO NOT HANDLETHIS AREA

SIDE VIEWS

REVISION HISTORYECO ZONE REV. DESCRIPTION DATE APPR'D

MINIMUM GAP TO CEILING'A'

CONDITION mm inSERVICE MODE 38 1.5TOOL ACCESS 165 6.5

PANEL REMOVAL ONLY 32 1.3MINIMUM GAP 17 0.7

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-LPRODUCT OUTLINE

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:5 DO NOT SCALESHEET

1 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

2. PANEL TEMPERATURES CAN INCREASE 3-5°C WITH EACH VERTICALLY STACKED UNIT.

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 2: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

19.249488.92

30.500774.70

47.8301214.87

26.996685.69

8.657219.90

.0150.38

NOMINAL

.0150.38

NOMINAL

53.981371.0

95.642429.4

23.390594.10

.83521.22

340.61032 3

14.6370

315.7400

36.1155

HORIZONTAL ALIGNMENTBRACKETS. USE M5X8BUTTON HEAD SCREWS

VERTICAL ALIGNMENTBRACKETS. USE M5X8BUTTON HEAD SCREWS

MOUNT HOLES FOR#1/4-20 OR M6 BOLTSAND WASHERS

DISPLAY OUTLINE

CENTERING NOTCHKICKSTAND FORSERVICE MODE

3 RECOMMENDED LOCATIONFOR CABLE INGRESS BETWEEN

PANEL COLUMNS

CABLE ROUTEFEATURES

SERVICE MODEHANGER TABS

30.50774.7

47.241200.0

3.3284.3

2X M6X15 STUDSFOR MOUNTINGTO LCD MOUNTS

.061.5

OPTIONAL LANDSCAPE WALL STUD ADAPTER BRACKET2 PER LCD MOUNT, ATTACHMENT ORIENTATION SHOWN

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-LMOUNT BRACKET LAYOUT

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:5 DO NOT SCALESHEET

2 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

5.

4. IT IS RECOMMENDED THAT FOR FLUSH MOUNT WALLS, A MINIMUM OF 13mm (0.5") GAP BE LEFT AT THE SIDES AND A MINIMUM OF 25mm (1.0") GAP BE LEFT AT THE BOTTOM. SEE PAGE ONE FOR TOP GAP RECOMMENDATIONS.

3. IT IS RECOMMENDED THAT A MINIMUM OF 5 FEET OF CABLE IS AVAILABLE FOR PANELS NEXT TO THE CONDUIT OPENING. MORE WILL BE NEEDED FOR PANELS FARTHER AWAY.

2. ENSURE THE LCD MOUNTS ARE MOUNTED FLAT, LEVEL AND PLUMB.

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 3: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

128.603266.3

52.021321.4

53.981371.0

143.473644.3

.8421.2

7.44189.0

36.1155

315.7400

340.61032 3

14.6370 DISPLAY OUTLINE3 RECOMMENDED LOCATION

FOR CABLE INGRESS BETWEENPANEL COLUMNS

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-L3X2 MOUNT BRACKET LAYOUT

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:5 DO NOT SCALESHEET

3 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

4. IT IS RECOMMENDED THAT FOR FLUSH MOUNT WALLS, A MINIMUM OF 13mm (0.5") GAP BE LEFT AT THE SIDES AND A MINIMUM OF 25mm (1.0") GAP BE LEFT AT THE BOTTOM. SEE PAGE ONE FOR TOP GAP RECOMMENDATIONS.

3. IT IS RECOMMENDED THAT A MINIMUM OF 5 FEET OF CABLE IS AVAILABLE FOR PANELS NEXT TO THE CONDUIT OPENING. MORE WILL BE NEEDED FOR PANELS FARTHER AWAY.

2. ENSURE THE LCD MOUNTS ARE MOUNTED FLAT, LEVEL AND PLUMB.

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 4: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

128.603266.3

79.022007.0

80.972056.7

143.473644.3

7.44189.0

.8421.2

36.1155

315.7400

340.61032 3

14.6370

DISPLAY OUTLINE3 RECOMMENDED LOCATION

FOR CABLE INGRESS BETWEENPANEL COLUMNS

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-L3X3 MOUNT BRACKET LAYOUT

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:5 DO NOT SCALESHEET

4 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

4. IT IS RECOMMENDED THAT FOR FLUSH MOUNT WALLS, A MINIMUM OF 13mm (0.5") GAP BE LEFT AT THE SIDES AND A MINIMUM OF 25mm (1.0") GAP BE LEFT AT THE BOTTOM. SEE PAGE ONE FOR TOP GAP RECOMMENDATIONS.

3. IT IS RECOMMENDED THAT A MINIMUM OF 5 FEET OF CABLE IS AVAILABLE FOR PANELS NEXT TO THE CONDUIT OPENING. MORE WILL BE NEEDED FOR PANELS FARTHER AWAY.

2. ENSURE THE LCD MOUNTS ARE MOUNTED FLAT, LEVEL AND PLUMB.

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 5: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

30.500774.70

47.8931216.47

27.059687.29

8.673220.30

.0150.38

NOMINAL

.0150.38

NOMINAL

54.041372.6

95.712431.0

23.405594.50

22.554572.88

.85121.62

315.7400

340.61032 3

14.6370

36.1155

2

HORIZONTAL ALIGNMENTBRACKETS. USE M5X8BUTTON HEAD SCREWS

VERTICAL ALIGNMENTBRACKETS. USE M5X8BUTTON HEAD SCREWS

MOUNT HOLES FOR#1/4-20 OR M6 BOLTSAND WASHERS

DISPLAY OUTLINE

CENTERING NOTCHKICKSTAND FORSERVICE MODE

CABLE ROUTEFEATURES

SERVICE MODEHANGER TABS

30.50774.7

47.241200.0

3.3284.3

2X M6X15 STUDSFOR MOUNTINGTO LCD MOUNTS

.061.5

OPTIONAL LANDSCAPE WALL STUD ADAPTER BRACKET2 PER LCD MOUNT, ATTACHMENT ORIENTATION SHOWN

3 RECOMMENDED LOCATIONFOR CABLE INGRESS BETWEEN

PANEL COLUMNS

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-LERO MOUNT BRACKET LAYOUT

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:5 DO NOT SCALESHEET

5 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

5.

4. IT IS RECOMMENDED THAT FOR FLUSH MOUNT WALLS, A MINIMUM OF 13mm (0.5") GAP BE LEFT AT THE SIDES AND A MINIMUM OF 25mm (1.0") GAP BE LEFT AT THE BOTTOM. SEE PAGE ONE FOR TOP GAP RECOMMENDATIONS.

3. IT IS RECOMMENDED THAT A MINIMUM OF 5 FEET OF CABLE IS AVAILABLE FOR PANELS NEXT TO THE CONDUIT OPENING. MORE WILL BE NEEDED FOR PANELS FARTHER AWAY.

2. ENSURE THE LCD MOUNTS ARE MOUNTED FLAT, LEVEL AND PLUMB.

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 6: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

.9925.1

RIGHT TRIM

.9925.1

LEFT TRIM

26.94684.3

3.4387.2

3.4387.2

26.94684.3

3.4286.9

47.781213.5

TOP TRIM

47.781213.5

3.4286.9

BOTTOM TRIM

2X KNOCKOUTS FORUSE WITH COLUMN STAND

TRIM INSTALLATION

LEFT TRM

RIGHT TRIM

BOTTOM TRIM

TOP TRIM

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-LTRIM INSTALL OPTIONS

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:5 DO NOT SCALESHEET

6 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

2. TOP, BOTTOM, LEFT AND RIGHT TRIM ARE 2mm THICK.

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 7: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

32.14816.4

1.61+-1.00.00

41.0+ 25.40.0

47.721212.1

4X LEVELINGFEET

3.6191.8

16.99431.5

27.25692.2

WITHOUT FLOORANCHORS

30.00762.0

WITH FLOORANCHORS

17.16435.9

CUSTOM HEIGHTSAVAILABLE

98.102491.7

4X FLOOR ANCHORS[ .38 ]

9.5 HOLE PROVIDED

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-LCOLUMN STAND

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:6 DO NOT SCALESHEET

7 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

4. TIE BACKS REQUIRED FOR WALLS EXCEEDING 7 FEET TALL AT THE TOP AND MINIMUM EVERY 7 FEET BEYOND.

3. STANDARD MAXIMUM THREE HEIGHT STACK. CONTACT PLANAR FOR CUSTOM OPTIONS FOR ADDITIONAL ROWS.

2. ADDITIONAL CUSTOM ACCESSORIES. CONTACT PLANAR SYSTEMS.CASTERSFLOOR ANCHORING WITHOUT FEETCUSTOM LENGTHS

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 8: WITH MOUNT D D · ejs ejs 20nov13 20nov13 planar systems, inc. 1195 nw compton drive beaverton, or 97006 usa clarity matrix mx55hdu-l mount bracket layout title size d part no.-drawing

STANDARD PANELDIMENSIONS

26.94684.4

ERO PANELDIMENSIONS

[26.98]685.2

STANDARD PANELDIMENSIONS

47.781213.6

ERO PANELDIMENSIONS

[47.81]1214.4

FRONT VIEWSTANDARD PANEL

TOP VIEW

BOTTOM VIEW

3.385

STANDARDPANEL

NOMINAL3.588

ERO PANELNOMINAL

ERO PANEL SHOWN

SIDE VIEW

ELECTRONICSINTERFACE

2X POSITION SENSORTRANSMITTER

POSITION SENSORRECEIVER

HANDLES

DO NOT HANDLETHIS AREA

15.748400.00

15.748400.00

BACK VIEW

4X M6X1.0

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

EJS

EJS

20NOV13

20NOV13PLANAR SYSTEMS, INC.1195 NW COMPTON DRIVEBEAVERTON, OR 97006 USA

CLARITY MATRIX MX55HDU-VVESA INSTALL OUTLINE

TITLE

SIZE

DPART NO.

-DRAWING NO.

UX2 55L Outline-REV

01SCALE

1:5 DO NOT SCALESHEET

8 OF 8

050-0218-00 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

2. ROTATE 90° CLOCKWISE AS VIEWED FROM THE FRONT FOR PORTRAIT ORIENTATION.

1. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.