WiringGuide - Bricomp

27
EP.MINI Wiring Guide Version 1.00 Last Updated: 19052009 1

Transcript of WiringGuide - Bricomp

Page 1: WiringGuide - Bricomp

EP.MINI  Wiring  Guide  

Version  1.00    Last  Updated:  19-­‐05-­‐2009  

1  

Page 2: WiringGuide - Bricomp

Note:  See  h>p://www.entrypass.net/  for  updates,  revisions,  and  download  the  latest  installaGon  manual      There  are  currently  2  version  of  EntryPass  PlaKorm1  Access  Control  System  available  for  different  card  number  system                1)  EntryPass  PlaKorm1  Access  Control  System  (6  Digit  Card  Number  System)  cater  for  6  digit  card                              number  installaGon                  2)EntryPass  PlaKorm1  Access  Control  System  (10  Digit  Card  Number  System)  cater  for  10  digit  card                          number  installaGon    For  EntryPass  PlaKorm1  Access  Control  System  to  work  correctly,  both  control  panel  and  soWware  MUST  be  using  the  same  card  number  system  This  soWware  installaGon  manual  might  be  updated  without  prior  noGce      Please  refer  to  separate  EntryPass  PlaKorm1  User  Manual  for  detail  operaGon  help.  The  Official  EntryPass  PlaKorm1  User  Manual  can  be  downloaded  from  our  website  under  “Download”  secGon  

         

2  

 Model:  EP.MINI  

Page 3: WiringGuide - Bricomp

Technical  Support    If  you  cannot  find  the  answer  to  your  quesGon  in  this  manual  or  in  the  Help  files,  we  recommend  you  contact  your  system  installer.  Your  installer  is  familiar  with  your  system  configuraGon  and  should  be  able  to  answer  any  of  your  quesGons.      Should  you  need  addiGonal  informaGon,  please  call  our  Technical  Support  Help  desk,  Monday  to  Friday  9:00  AM  to  6:00  PM  (GMT  +8:00)    Method  Details  Phone  +  60  (3)  -­‐  8068  1929  Fax  +  60  (3)  -­‐  8068  1922  Internet  www.entrypass.net  Email  [email protected]        

 

Before  you  begin

3  

 Model:  EP.MINI  

Page 4: WiringGuide - Bricomp

CAUTION  Ba>ery  may  explode  if  mistreated.  Do  not  recharge,  disassemble  or  dispose  of  in  fire.  To  prevent  a  risk  of  explosion  do  not  pry  the  ba>ery  out  with  a  metal  or  conducGve  tool.  

ConsideraGons  Prior  to  InstallaGon  

Preparing  Your  EntryPass  Controllers    EntryPass  controller  contains  numerous  delicate  electronic  circuits  and  components  which  can  become  damaged  as  a  result  of  electrostaGc  discharge  (ESD).  Thus,  prior  to  installaGon,  please  follow  the  instrucGon  below:  • Observe  precauGons  while  handling  the  circuit  board  assembly  by  using  proper  grounding  straps  and  handling            precauGons  at  all  • Visually  ensure  no  onboard  parts  is  broken,  damage  or  contains  burn  mark  • Do  not  turn  on  the  power  supply  unGl  you  completed  all  wiring  and  external  add  on  devices  installaGons  

Instances  of  Non-­‐Warranty  • Damage  due  to  natural  disaster,  accident  or  human  cause.  • Damage  as  a  result  of  violaGng  the  condiGons  recommended  in  the  user  manual  • Damage  due  to  improper  installaGon  • Damage  due  to  use  of  uncerGfied  components  • Damage  due  to  use  exceeding  the  permi>ed  parameters    

4  

 Model:  EP.MINI  

Page 5: WiringGuide - Bricomp

 Model:  EP.MINI  MiNi  DescripGon    

MiNi  Reader    Keypad  Display  Unit  

Encrypted  Lock  Control    (ELC)    

5  

Page 6: WiringGuide - Bricomp

 Model:  EP.MINI  MiNi  Color  DescripGon    

Encrypted  Lock  Control  (ELC)  DescripGon    Red      :  +12VDC  Black    :  GND  /  0VDC  Orange              :  RCLK  Yellow              :  RDAT  Blue              :  RTX  Pink              :  Push  Bu>on  Red            :  +12VDC  Black              :  GND  /  0VDC  Grey  /  Yellow    :  NO1  White  /  Blue        :  CM1  White            :  NC1  Brown              :  NO2  Grey            :  CM2  Green            :  NC2  Purple            :  +12Vdc  Lock  Purple            :  +12Vdc  Lock  

MiNi  Reader  Color  DescripGon    Red  :  +12VDC  Black  :  GND  /  0VDC  Pink  :  Door  Sensor  Black  :  GND  /  0VDC  Blue  :  RTX  Brown  :  +  5VDC  White  :  Exit  Reader  D1  Green  :  Exit  Reader  DO  Orange  :  RCLK  Yellow  :  RDAT  Grey  :  RS485  C+  Purple  :  RS485  C-­‐    Green  :  RS232  RX  Separated  White  :  RS232  TX  Separated  

6  

Page 7: WiringGuide - Bricomp

 Model:  EP.MINI  MiNi  reader  keypad  display  unit    

White  LCD  Display  

Enter  Key  

Numbered  Keypad  

NavigaGon  Pad  

LED  Indicator  

7  

Page 8: WiringGuide - Bricomp

Power  Supply  Unit  SpecificaGon  

8  

 Model:  EP.MINI  

Power  Supply  Unit  SpecificaGon:  •   Switching  Power  Supply  •   12V  DC  •   3  Amp  (Minimum)  

Page 9: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  MINI  to  ELC  

0  V +12  VDC

Switching  Mode  Power  Supply  Unit  

(12V  DC,  3A  Minimum)

Red  (+12VDC)Black  (Gnd)

Red  (+12VDC)Black  (Gnd)

Blue  (RTX) Blue  (RTX)Orange  (RCLK) Orange  (RCLK)Yellow  (RDAT) Yellow  (RDAT)

The  distance  from  MINI  keypad  reader  to  ELC  should  not  more  than  10  meter  

9  

Page 10: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  the  Lock  (NC),  Breakglass  and  Keyswitch  to  ELC    

+-

White/Blue  (CM1)White  (NC1)

0V

Emergency Breakglass

Emergency Keyswitch

Electro-Magnetic Lock

-+

Purple  (+12VDC)Purple  (+12VDC)

Switching  Mode  Power  Supply  Unit  

(12V  DC,  3A  Minimum)

Diode(1N4002)  must  be  installed  at  the  locking  devices  in  order  to  protect  against  back  EMF  

10  

Page 11: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  the  Lock  (NO)  

11  

Diode(1N4002)  must  be  installed  at  the  locking  devices  in  order  to  protect  against  back  EMF  

+-

White/Blue  (CM1)

Grey/Yellow  (NO1)

0V

Electro-Magnetic Lock (Drop Bolt)

-+

Purple  (+12VDC)Purple  (+12VDC)

Switching  Mode  Power  Supply  Unit  

(12V  DC,  3A  Minimum)

Page 12: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  the  Door  Sensor  and  Door  Release  Bu>on/Push  Bu>on    

The  distance  from  door  sensor  to  MINI  and  from  push  bu>on  to  ELC  should  not  more  than  30  meter  

12  

Door  Sensor Push  Button

Pink  (Door  Sensor)Black  (Gnd)

Pink  (Push  Button)Black  (Gnd)

Page 13: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  the  Exit  Reader  –  MINI  reader  as  an  exit  reader    

To  use  MINI/NMINI  on  exit  reader  side,  you  must  enable  the  READER  MODE  funcGon  on  the  programming  mode  

To  configure  MINI  as  a  READER  Mode,  press:  • F1    • 123456  • 01  Enter  • 01  Enter  • 05  Enter  • 1  Enter  • ESC  x3  

To  configure  NMINI  as  a  READER  Mode,  press:  • F1    • 123456  • 01  Enter  • 01  Enter  • 04  Enter  • 1  Enter  • ESC  x3  

0  V +12  VDC

Exit  Reader

Switching  Mode  Power  Supply  Unit  

(12V  DC,  3A  Minimum)

Green  (D0)White  (D1)

Black  (Gnd)  Red  (+12VDC)

Black  (Gnd)  Red  (+12VDC)Orange  (RCLK)Yellow  (RDAT)

13  

Page 14: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  the  Exit  Reader  –  3rd    Party  Reader      

0  V +12  VDC

Green  (D0)White  (D1)

Black  (Gnd)  Red  (+12VDC)

Green  (D0)White  (D1)

Exit  Reader

Black  (Gnd)  Red  (+12VDC)

Switching  Mode  Power  Supply  Unit  

(12V  DC,  3A  Minimum)

The  distance  from  MINI  to  exit  reader  should  not  more  than  10  meter    

14  

Page 15: WiringGuide - Bricomp

 Model:  EP.MINI  Configuring  the  MINI  Unit  Address      

15  

Unit  Address   SoIware  address  field  

00   255.255.255.0  

01   255.255.255.1  

02   255.255.255.2  

03   255.255.255.3  

04   255.255.255.4  

05   255.255.255.5  

06   255.255.255.6  

07   255.255.255.7  

08   255.255.255.8  

09   255.255.255.9  

10   255.255.255.10  

11   255.255.255.11  

12   255.255.255.12  

13   255.255.255.13  

14   255.255.255.14  

15   255.255.255.15  

To  configure  MINI  unit  address  (default:  00),  press:  • F1    • 123456  • 01  Enter  • 01  Enter  • 04  Enter  • Key  in  new  unit  address    (00  –  15)    • ESC  x3  

The  unit  address  that  you  configure  on  the  MINI  controller  will  determine  the  controller  address  on  the  EntryPass  PlaKorm1  Access  Control  System  

soWware  

Page 16: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  to  the  PC  using  RS  232  mode  

The  distance  from  computer  to  MINI  should  not  more  than  10  meter  

DB  9  Female  Connecter

White  to  Pin  2Green  to  Pin  3Black  to  Pin  5

Green  (RS  232  RX)White  (RS  232  TX)

Black  (Gnd)

EntryPass Platform1 Server Access Control System

16  

Page 17: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  to  the  PC  using  RS  485  mode  

To  configure  MINI  unit  address  (default:  00),  press:  • F1    • 123456  • 01  Enter  • 01  Enter  • 04  Enter  • Key  in  new  unit  address    (00  –  15)    • ESC  x3  

17  

When  the  implementaGon  consists  of  more  than  1  MINI  to  be  connected  to  the  PC  using  the  same  bus/comport,  the  unit  address  for  each  MINI  must  be  unique.  

Only  a  total  of  16  controllers  can  be  connected  to  each  bus/comport.  

Purple  (C-­‐)Purple  (C-­‐)Grey  (C+)Grey  (C+) Grey  (C+)

C-­‐

C+

Purple  (C-­‐)

MINI  16Unit  Address:  15

MINI  2Unit  Address:  01

MINI  1Unit  Address:  00

PCC  (Pc  Communicator)

RS  232:  10  meterRS232

Power Tx Rx

EntryPass  Platform1  Server  Access  Control  System

RS  485:  I000  meter  (Maximum)

Page 18: WiringGuide - Bricomp

 Model:  EP.MINI  ConnecGng  to  the  power  supply  unit  

0  V +12  VDC

Red/Yellow  (+12VDC)Black  (Gnd)

Switching  Mode  Power  Supply  Unit  

(12V  DC,  3A  Minimum)

18  

Page 19: WiringGuide - Bricomp

 Model:  EP.MINI  Complete  overview  

19  

+-

White/Blue  (CM1)

0V

Emergency Breakglass

Emergency Keyswitch

Electro-Magnetic Lock

-+

Purple  (+12VDC)

Door  Sensor

Push  Button

Black  (Gnd)

Exit  Reader

Black  (Gnd)Red/Yellow  (+12VDC)

+12  VDC

Switching  Mode  Power  Supply  Unit  

(12V  DC,  3A  Minimum)

EntryPass Platform1 Server Access Control System

White  (NC1)

Orange  (RCLK)Yellow  (RDAT)

Blue  (RTX)Pink  (Push  Button)

Red  (+12VDC)Black  (Gnd)

Orange  (RCLK)Yellow  (RDAT)Blue  (RTX)Red  (+12VDC)Green  (D0)White  (D1)Black  (Gnd)Pink  (Door  Sensor)

RS232

Power Tx Rx

Grey  (C+)Purple  (C-­‐)

PCC  (Pc  Communicator)

C+

C-­‐

Page 20: WiringGuide - Bricomp

 Model:  EP.MINI  Before  connecGng  to  the  EntryPass  PlaKorm1  Access  Control  System  

Before  you  begin  to  connect  to  the  EntryPass  PlaKorm1  Access  Control  System,  please  make  sure  all  the  wiring  connecGon  is  correct.  On  the  MINI  keypad,  please  make  sure  the  following  seong  

has  been  done:  

Form

at  M

emory  

Unit  A

ddress  

Advisable  to  perform  format  memory  for  the  first  Gme  you  turn  

on  the  power  

To  configure  the  EP.MINI  unit  address  if  there  is  more  than  one  MINI  controller  connected  to  the  PC  

communicator    

20  

Page 21: WiringGuide - Bricomp

 Model:  EP.MINI  MINI  (6  digit  firmware)  Programming  Mode  

21  

To  enter  programming  mode,  press:  • F1  • 123456  (default  admin  pin)  

Admin  Pin  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 01  Enter  • Key  in  new  admin  pin  (6  digits)  • ESC  X3    Normal  Pin  • Enter  programming  style  • 01  Enter  • 01  Enter  • 02  Enter  • Key  in  new  normal  pin  (6  digits)  • ESC  X3    Security  Level  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 03  Enter  • 1  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3    Unit  Address  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 04  Enter  • Key  in  the  new  unit  address  (00  -­‐  15  sets)  • ESC  X3    Reader  Mode  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 05  Enter  • 1  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3                              

Inhibit  Mode  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 01  Enter  • 1  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3      Security  Mode  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 02  Enter  • 0  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3    Site  Code  1  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 03  Enter  • Key  in  the  new  site  code  (4  digits)  • ESC  X3    Site  Code  2  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 04  Enter  • Key  in  the  new  site  code  (4  digits)  • ESC  X3    Site  Code  3  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 05  Enter  • Key  in  the  new  site  code  (4  digits)  • ESC  X3                              

Door  Pin  1    • Enter  programming  mode  • 01  Enter  • 02  Enter  • 06  Enter  • Key  in  the  new  door  pin  (6  digits)  • 09  Enter  • 01  • ESC  X3    Door  Pin  2  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 07  Enter  • Key  in  the  new  door  pin  (6  digits)  • 10  Enter    • 01  • ESC  X3    Door  Pin  3  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 08  Enter  • Key  in  the  new  door  pin  (6  digits)  • 11  Enter    • 01  • ESC  X3    Door  Pin  1  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 09  Enter  • Key  in  the  new  door  pin  Gmezone  • ESC  X3    

Page 22: WiringGuide - Bricomp

 Model:  EP.MINI  MINI  (6  digit  firmware)  Programming  Mode  

22  

Door  Pin  2  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 10  Enter  • Key  in  the  new  door  pin  Gmezone  • ESC  X3    Door  Pin  3  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 11  Enter  • Key  in  the  new  door  pin  Gmezone  • ESC  X3    Exit  Bu]on  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 12  Enter  • Key  in  the  new  exit  bu>on  Gmezone  • ESC  X3    Auto  Release  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter    • 13  Enter  • Key  in  the  new  auto  release  Gmezone  • ESC  X3    Release  Time  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 14  Enter  • Key  in  the  new  release  Gme  (00  –  99)  • ESC  X3                            

Open  Time  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 15  Enter  • Key  in  the  new  open  Gme  (00  –  99)  • ESC  X3    Pin  Trials  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 16  Enter  • Key  in  the  new  pin  trials  (00  –  09)  • ESC  X3    Card+Pin  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 17  Enter  • Key  in  the  new  card+pin  Gmezone  • ESC  X3    Date  Se^ng  • Enter  programming  mode  • 01  Enter  • 03  Enter  • Key  in  the  new  date  (DDMMYY)  • ESC  X2    Time  Se^ng  • Enter  programming  mode  • 01  Enter  • 04  Enter  • Key  in  the  new  Gme  (HHMMSS)  • ESC  X2                                

Reset  Password  • Enter  programming  mode  • 01  Enter  • 05  Enter  • 01  Enter  • ESC  X2    Reset  Door  Data  • Enter  programming  mode  • 01  Enter  • 05  Enter  • 02  Enter  • ESC  X2    Format  Memory  • Enter  programming  mode  • 01  Enter  • 05  Enter  • 03  Enter  • When  finish  formaong,  a  beep  sound  will  be  heard  • ESC  X2    Install  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 01  Enter  • Key  in  the  card  number  (6  digits)  • ESC  X3    Delete  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 02  Enter  • Key  in  the  card  number  (6  digits)  • ESC  X3    

     

Page 23: WiringGuide - Bricomp

 Model:  EP.MINI  MINI  (6  digit  firmware)  Programming  Mode  

23  

View  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 03  Enter  • Key  in  the  card  number  (6  digits)  • ESC  X4    Quick  Install  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 04  Enter  • Flash  all  the  cards  to  be  installed  (card  by  card)  • ESC  X4    Quick  Delete  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 05  Enter  • Flash  all  the  cards  to  be  deleted  (card  by  card)  • ESC  X4    Reset  Card  Pin  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 06  Enter  • Key  in  the  card  number  that  need  to  perform  pin  reset  (6              digits)  • ESC  X3    Reset  Lockout  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 07  Enter  • 1  Enter    • ESC  X3  

Reset  Lockout  Time  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 08  Enter  • Key  in  the  reset  lockout  Gme  (HHMM)  • ESC  X3    Total  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 09  Enter  • ESC  X3    TransacGon  • Enter  programming  mode  • 02  Enter  • 02  Enter  • Press  F3  bu>on  to  view  the  next  transacGon  event  or  F1                              bu>on  to  go  back  to  previous  transacGon  event  • ESC  X3      Info  Menu  • Enter  programming  mode  • 03  Enter  • ESC  X2    

     

Page 24: WiringGuide - Bricomp

Admin  Pin  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 01  Enter  • Key  in  new  admin  pin  (6  digits)  • ESC  X3    Normal  Pin  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 02  Enter  • Key  in  new  normal  pin  (6  digits)  • ESC  X3    Security  Level  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 03  Enter  • 1  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3    Unit  Address  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 04  Enter  • Key  in  the  new  unit  address  (00  -­‐  15  sets)  • ESC  X3    Reader  Mode  • Enter  programming  mode  • 01  Enter  • 01  Enter  • 05  Enter  • 1  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3                              

 Inhibit  Mode  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 01  Enter  • 1  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3      Security  Mode  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 02  Enter  • 0  Enter  (Press  1  to  set  it  ON  or  press  0  to  set  it  OFF)  • ESC  X3    Door  Pin  1    • Enter  programming  mode  • 01  Enter  • 02  Enter  • 03  Enter  • Key  in  the  new  door  pin  (6  digits)  • 06  Enter    • 01  • ESC  X3    Door  Pin  2  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 04  Enter  • Key  in  the  new  door  pin  (6  digits)  • 07  Enter    • 01  • ESC  X3                                    

 Door  Pin  3  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 05  Enter  • Key  in  the  new  door  pin  (6  digits)  • 08  Enter    • 01  • ESC  X3    Door  Pin  1  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 06  Enter  • Key  in  the  new  door  pin  Gmezone  • ESC  X3    Door  Pin  2  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 07  Enter  • Key  in  the  new  door  pin  Gmezone  • ESC  X3    Door  Pin  3  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 08  Enter  • Key  in  the  new  door  pin  Gmezone  • ESC  X3      

 Model:  EP.MINI  MINI  (10  digit  firmware)  Programming  Mode  

24  MINI  programming  mode  for  10  digit  firmware  does  not  have  site  code  

Page 25: WiringGuide - Bricomp

Exit  Bu]on  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 09  Enter  • Key  in  the  new  exit  bu>on  Gmezone  • ESC  X3    Auto  Release  Tz  • Enter  programming  mode  • 01  Enter  • 02  Enter    • 10  Enter  • Key  in  the  new  auto  release  Gmezone  • ESC  X3    Release  Time  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 11  Enter  • Key  in  the  new  release  Gme  (00  –  99)  • ESC  X3    Open  Time  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 12  Enter  • Key  in  the  new  open  Gme  (00  –  99)  • ESC  X3    Pin  Trials  • Enter  programming  mode  • 01  Enter  • 02  Enter  • 13  Enter  • Key  in  the  new  pin  trials  (00  –  09)  • ESC  X3                        Card+Pin  Tz  • Enter  programming  mode  

• 01  Enter  • 02  Enter  • 14  Enter  • Key  in  the  new  card+pin  Gmezone  • ESC  X3    Date  Se^ng  • Enter  programming  mode  • 01  Enter  • 03  Enter  • Key  in  the  new  date  (DDMMYY)  • ESC  X2    Time  Se^ng  • Enter  programming  mode  • 01  Enter  • 04  Enter  • Key  in  the  new  Gme  (HHMMSS)  • ESC  X2    Reset  Password  • Enter  programming  mode  • 01  Enter  • 05  Enter  • 01  Enter  • ESC  X2    Reset  Door  Data  • Enter  programming  mode  • 01  Enter  • 05  Enter  • 02  Enter  • ESC  X2                                    Format  Memory  • Enter  programming  mode  

• 01  Enter  • 05  Enter  • 03  Enter  • When  finish  formaong,  a  beep  sound  will  be  heard  • ESC  X2    Install  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 01  Enter  • Key  in  the  card  number  (10  digits)  • ESC  X3    Delete  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 02  Enter  • Key  in  the  card  number  (10  digits)  • ESC  X3    View  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 03  Enter  • Key  in  the  card  number  (10  digits)  • ESC  X4    Quick  Install  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 04  Enter  • Flash  all  the  cards  to  be  installed  (card  by  card)  • ESC  X4    

     

 Model:  EP.MINI  MINI  (10  digit  firmware)  Programming  Mode  

25  MINI  programming  mode  for  10  digit  firmware  does  not  have  site  code  

Page 26: WiringGuide - Bricomp

 Model:  EP.MINI  MINI  (10  digit  firmware)  Programming  Mode  

26  

MINI  programming  mode  for  10  digit  firmware  does  not  have  site  code  

Quick  Delete  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 05  Enter  • Flash  all  the  cards  to  be  deleted  (card  by  card)  • ESC  X4    Reset  Card  Pin  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 06  Enter  • Key  in  the  card  number  that  need  to  perform  pin  reset            (10  digits)  • ESC  X3    Reset  Lockout  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 07  Enter  • 1  Enter    • ESC  X3    Reset  Lockout  Time  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 08  Enter  • Key  in  the  reset  lockout  Gme  (HHMM)  • ESC  X3    Total  Card  • Enter  programming  mode  • 02  Enter  • 01  Enter  • 09  Enter  • ESC  X3  TransacGon  

• Enter  programming  mode  • 02  Enter  • 02  Enter  • Press  F3  bu>on  to  view  the  next  transacGon  event  or  F1            bu>on  to  go  back  to  previous  transacGon  event  • ESC  X3      Info  Menu  • Enter  programming  mode  • 03  Enter  • ESC  X2    

     

Page 27: WiringGuide - Bricomp

 Model:  EP.MINI  

Advisable  to  perform  format  memory  for  the  first  Gme  you  turn  

on  the  power  

To  configure  the  EP.MINI  unit  address  if  there  is  more  than  1  MINI  controller  

connected  to  the  PC  communicator    

Cabling  InformaGon  

CommunicaGon     Data  Signal   Max  Distance   DescripGon  

MINI  to  ELC   10m  (30  W)  

22  AWG,  3  Pairs,  Shielded    

Computer  to  PC  Communicator    

RS  232     10m  (30  W)  

22  AWG,  2  Pairs,  Shielded  

PC  Communicator  to  MINI  

RS  485   1000m  (3000  W)  

22  AWG,  2  Pairs,  Shielded  

MINI  to  exit  reader   Wiegand     10m  (30  W)  

22  AWG,  2  Pairs,  Shielded  

ELC  to  Electro-­‐MagneGc  Lock  

Power   30m  (100  W)  

18  AWG,  1  Pair  

ELC  to  Push  Bu>on   Contact   30m  (100  W)  

22AWG,  1  Pair  

MINI  to  Door  Sensor   Contact     30m  (100  W)  

22AWG,  1  Pair    

27