WiringGuide - Bricomp
Transcript of WiringGuide - Bricomp
EP.MINI Wiring Guide
Version 1.00 Last Updated: 19-‐05-‐2009
1
Note: See h>p://www.entrypass.net/ for updates, revisions, and download the latest installaGon manual There are currently 2 version of EntryPass PlaKorm1 Access Control System available for different card number system 1) EntryPass PlaKorm1 Access Control System (6 Digit Card Number System) cater for 6 digit card number installaGon 2)EntryPass PlaKorm1 Access Control System (10 Digit Card Number System) cater for 10 digit card number installaGon For EntryPass PlaKorm1 Access Control System to work correctly, both control panel and soWware MUST be using the same card number system This soWware installaGon manual might be updated without prior noGce Please refer to separate EntryPass PlaKorm1 User Manual for detail operaGon help. The Official EntryPass PlaKorm1 User Manual can be downloaded from our website under “Download” secGon
2
Model: EP.MINI
Technical Support If you cannot find the answer to your quesGon in this manual or in the Help files, we recommend you contact your system installer. Your installer is familiar with your system configuraGon and should be able to answer any of your quesGons. Should you need addiGonal informaGon, please call our Technical Support Help desk, Monday to Friday 9:00 AM to 6:00 PM (GMT +8:00) Method Details Phone + 60 (3) -‐ 8068 1929 Fax + 60 (3) -‐ 8068 1922 Internet www.entrypass.net Email [email protected]
Before you begin
3
Model: EP.MINI
CAUTION Ba>ery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. To prevent a risk of explosion do not pry the ba>ery out with a metal or conducGve tool.
ConsideraGons Prior to InstallaGon
Preparing Your EntryPass Controllers EntryPass controller contains numerous delicate electronic circuits and components which can become damaged as a result of electrostaGc discharge (ESD). Thus, prior to installaGon, please follow the instrucGon below: • Observe precauGons while handling the circuit board assembly by using proper grounding straps and handling precauGons at all • Visually ensure no onboard parts is broken, damage or contains burn mark • Do not turn on the power supply unGl you completed all wiring and external add on devices installaGons
Instances of Non-‐Warranty • Damage due to natural disaster, accident or human cause. • Damage as a result of violaGng the condiGons recommended in the user manual • Damage due to improper installaGon • Damage due to use of uncerGfied components • Damage due to use exceeding the permi>ed parameters
4
Model: EP.MINI
Model: EP.MINI MiNi DescripGon
MiNi Reader Keypad Display Unit
Encrypted Lock Control (ELC)
5
Model: EP.MINI MiNi Color DescripGon
Encrypted Lock Control (ELC) DescripGon Red : +12VDC Black : GND / 0VDC Orange : RCLK Yellow : RDAT Blue : RTX Pink : Push Bu>on Red : +12VDC Black : GND / 0VDC Grey / Yellow : NO1 White / Blue : CM1 White : NC1 Brown : NO2 Grey : CM2 Green : NC2 Purple : +12Vdc Lock Purple : +12Vdc Lock
MiNi Reader Color DescripGon Red : +12VDC Black : GND / 0VDC Pink : Door Sensor Black : GND / 0VDC Blue : RTX Brown : + 5VDC White : Exit Reader D1 Green : Exit Reader DO Orange : RCLK Yellow : RDAT Grey : RS485 C+ Purple : RS485 C-‐ Green : RS232 RX Separated White : RS232 TX Separated
6
Model: EP.MINI MiNi reader keypad display unit
White LCD Display
Enter Key
Numbered Keypad
NavigaGon Pad
LED Indicator
7
Power Supply Unit SpecificaGon
8
Model: EP.MINI
Power Supply Unit SpecificaGon: • Switching Power Supply • 12V DC • 3 Amp (Minimum)
Model: EP.MINI ConnecGng MINI to ELC
0 V +12 VDC
Switching Mode Power Supply Unit
(12V DC, 3A Minimum)
Red (+12VDC)Black (Gnd)
Red (+12VDC)Black (Gnd)
Blue (RTX) Blue (RTX)Orange (RCLK) Orange (RCLK)Yellow (RDAT) Yellow (RDAT)
The distance from MINI keypad reader to ELC should not more than 10 meter
9
Model: EP.MINI ConnecGng the Lock (NC), Breakglass and Keyswitch to ELC
+-
White/Blue (CM1)White (NC1)
0V
Emergency Breakglass
Emergency Keyswitch
Electro-Magnetic Lock
-+
Purple (+12VDC)Purple (+12VDC)
Switching Mode Power Supply Unit
(12V DC, 3A Minimum)
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
10
Model: EP.MINI ConnecGng the Lock (NO)
11
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
+-
White/Blue (CM1)
Grey/Yellow (NO1)
0V
Electro-Magnetic Lock (Drop Bolt)
-+
Purple (+12VDC)Purple (+12VDC)
Switching Mode Power Supply Unit
(12V DC, 3A Minimum)
Model: EP.MINI ConnecGng the Door Sensor and Door Release Bu>on/Push Bu>on
The distance from door sensor to MINI and from push bu>on to ELC should not more than 30 meter
12
Door Sensor Push Button
Pink (Door Sensor)Black (Gnd)
Pink (Push Button)Black (Gnd)
Model: EP.MINI ConnecGng the Exit Reader – MINI reader as an exit reader
To use MINI/NMINI on exit reader side, you must enable the READER MODE funcGon on the programming mode
To configure MINI as a READER Mode, press: • F1 • 123456 • 01 Enter • 01 Enter • 05 Enter • 1 Enter • ESC x3
To configure NMINI as a READER Mode, press: • F1 • 123456 • 01 Enter • 01 Enter • 04 Enter • 1 Enter • ESC x3
0 V +12 VDC
Exit Reader
Switching Mode Power Supply Unit
(12V DC, 3A Minimum)
Green (D0)White (D1)
Black (Gnd) Red (+12VDC)
Black (Gnd) Red (+12VDC)Orange (RCLK)Yellow (RDAT)
13
Model: EP.MINI ConnecGng the Exit Reader – 3rd Party Reader
0 V +12 VDC
Green (D0)White (D1)
Black (Gnd) Red (+12VDC)
Green (D0)White (D1)
Exit Reader
Black (Gnd) Red (+12VDC)
Switching Mode Power Supply Unit
(12V DC, 3A Minimum)
The distance from MINI to exit reader should not more than 10 meter
14
Model: EP.MINI Configuring the MINI Unit Address
15
Unit Address SoIware address field
00 255.255.255.0
01 255.255.255.1
02 255.255.255.2
03 255.255.255.3
04 255.255.255.4
05 255.255.255.5
06 255.255.255.6
07 255.255.255.7
08 255.255.255.8
09 255.255.255.9
10 255.255.255.10
11 255.255.255.11
12 255.255.255.12
13 255.255.255.13
14 255.255.255.14
15 255.255.255.15
To configure MINI unit address (default: 00), press: • F1 • 123456 • 01 Enter • 01 Enter • 04 Enter • Key in new unit address (00 – 15) • ESC x3
The unit address that you configure on the MINI controller will determine the controller address on the EntryPass PlaKorm1 Access Control System
soWware
Model: EP.MINI ConnecGng to the PC using RS 232 mode
The distance from computer to MINI should not more than 10 meter
DB 9 Female Connecter
White to Pin 2Green to Pin 3Black to Pin 5
Green (RS 232 RX)White (RS 232 TX)
Black (Gnd)
EntryPass Platform1 Server Access Control System
16
Model: EP.MINI ConnecGng to the PC using RS 485 mode
To configure MINI unit address (default: 00), press: • F1 • 123456 • 01 Enter • 01 Enter • 04 Enter • Key in new unit address (00 – 15) • ESC x3
17
When the implementaGon consists of more than 1 MINI to be connected to the PC using the same bus/comport, the unit address for each MINI must be unique.
Only a total of 16 controllers can be connected to each bus/comport.
Purple (C-‐)Purple (C-‐)Grey (C+)Grey (C+) Grey (C+)
C-‐
C+
Purple (C-‐)
MINI 16Unit Address: 15
MINI 2Unit Address: 01
MINI 1Unit Address: 00
PCC (Pc Communicator)
RS 232: 10 meterRS232
Power Tx Rx
EntryPass Platform1 Server Access Control System
RS 485: I000 meter (Maximum)
Model: EP.MINI ConnecGng to the power supply unit
0 V +12 VDC
Red/Yellow (+12VDC)Black (Gnd)
Switching Mode Power Supply Unit
(12V DC, 3A Minimum)
18
Model: EP.MINI Complete overview
19
+-
White/Blue (CM1)
0V
Emergency Breakglass
Emergency Keyswitch
Electro-Magnetic Lock
-+
Purple (+12VDC)
Door Sensor
Push Button
Black (Gnd)
Exit Reader
Black (Gnd)Red/Yellow (+12VDC)
+12 VDC
Switching Mode Power Supply Unit
(12V DC, 3A Minimum)
EntryPass Platform1 Server Access Control System
White (NC1)
Orange (RCLK)Yellow (RDAT)
Blue (RTX)Pink (Push Button)
Red (+12VDC)Black (Gnd)
Orange (RCLK)Yellow (RDAT)Blue (RTX)Red (+12VDC)Green (D0)White (D1)Black (Gnd)Pink (Door Sensor)
RS232
Power Tx Rx
Grey (C+)Purple (C-‐)
PCC (Pc Communicator)
C+
C-‐
Model: EP.MINI Before connecGng to the EntryPass PlaKorm1 Access Control System
Before you begin to connect to the EntryPass PlaKorm1 Access Control System, please make sure all the wiring connecGon is correct. On the MINI keypad, please make sure the following seong
has been done:
Form
at M
emory
Unit A
ddress
Advisable to perform format memory for the first Gme you turn
on the power
To configure the EP.MINI unit address if there is more than one MINI controller connected to the PC
communicator
20
Model: EP.MINI MINI (6 digit firmware) Programming Mode
21
To enter programming mode, press: • F1 • 123456 (default admin pin)
Admin Pin • Enter programming mode • 01 Enter • 01 Enter • 01 Enter • Key in new admin pin (6 digits) • ESC X3 Normal Pin • Enter programming style • 01 Enter • 01 Enter • 02 Enter • Key in new normal pin (6 digits) • ESC X3 Security Level • Enter programming mode • 01 Enter • 01 Enter • 03 Enter • 1 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3 Unit Address • Enter programming mode • 01 Enter • 01 Enter • 04 Enter • Key in the new unit address (00 -‐ 15 sets) • ESC X3 Reader Mode • Enter programming mode • 01 Enter • 01 Enter • 05 Enter • 1 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3
Inhibit Mode • Enter programming mode • 01 Enter • 02 Enter • 01 Enter • 1 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3 Security Mode • Enter programming mode • 01 Enter • 02 Enter • 02 Enter • 0 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3 Site Code 1 • Enter programming mode • 01 Enter • 02 Enter • 03 Enter • Key in the new site code (4 digits) • ESC X3 Site Code 2 • Enter programming mode • 01 Enter • 02 Enter • 04 Enter • Key in the new site code (4 digits) • ESC X3 Site Code 3 • Enter programming mode • 01 Enter • 02 Enter • 05 Enter • Key in the new site code (4 digits) • ESC X3
Door Pin 1 • Enter programming mode • 01 Enter • 02 Enter • 06 Enter • Key in the new door pin (6 digits) • 09 Enter • 01 • ESC X3 Door Pin 2 • Enter programming mode • 01 Enter • 02 Enter • 07 Enter • Key in the new door pin (6 digits) • 10 Enter • 01 • ESC X3 Door Pin 3 • Enter programming mode • 01 Enter • 02 Enter • 08 Enter • Key in the new door pin (6 digits) • 11 Enter • 01 • ESC X3 Door Pin 1 Tz • Enter programming mode • 01 Enter • 02 Enter • 09 Enter • Key in the new door pin Gmezone • ESC X3
Model: EP.MINI MINI (6 digit firmware) Programming Mode
22
Door Pin 2 Tz • Enter programming mode • 01 Enter • 02 Enter • 10 Enter • Key in the new door pin Gmezone • ESC X3 Door Pin 3 Tz • Enter programming mode • 01 Enter • 02 Enter • 11 Enter • Key in the new door pin Gmezone • ESC X3 Exit Bu]on Tz • Enter programming mode • 01 Enter • 02 Enter • 12 Enter • Key in the new exit bu>on Gmezone • ESC X3 Auto Release Tz • Enter programming mode • 01 Enter • 02 Enter • 13 Enter • Key in the new auto release Gmezone • ESC X3 Release Time • Enter programming mode • 01 Enter • 02 Enter • 14 Enter • Key in the new release Gme (00 – 99) • ESC X3
Open Time • Enter programming mode • 01 Enter • 02 Enter • 15 Enter • Key in the new open Gme (00 – 99) • ESC X3 Pin Trials • Enter programming mode • 01 Enter • 02 Enter • 16 Enter • Key in the new pin trials (00 – 09) • ESC X3 Card+Pin Tz • Enter programming mode • 01 Enter • 02 Enter • 17 Enter • Key in the new card+pin Gmezone • ESC X3 Date Se^ng • Enter programming mode • 01 Enter • 03 Enter • Key in the new date (DDMMYY) • ESC X2 Time Se^ng • Enter programming mode • 01 Enter • 04 Enter • Key in the new Gme (HHMMSS) • ESC X2
Reset Password • Enter programming mode • 01 Enter • 05 Enter • 01 Enter • ESC X2 Reset Door Data • Enter programming mode • 01 Enter • 05 Enter • 02 Enter • ESC X2 Format Memory • Enter programming mode • 01 Enter • 05 Enter • 03 Enter • When finish formaong, a beep sound will be heard • ESC X2 Install Card • Enter programming mode • 02 Enter • 01 Enter • 01 Enter • Key in the card number (6 digits) • ESC X3 Delete Card • Enter programming mode • 02 Enter • 01 Enter • 02 Enter • Key in the card number (6 digits) • ESC X3
Model: EP.MINI MINI (6 digit firmware) Programming Mode
23
View Card • Enter programming mode • 02 Enter • 01 Enter • 03 Enter • Key in the card number (6 digits) • ESC X4 Quick Install • Enter programming mode • 02 Enter • 01 Enter • 04 Enter • Flash all the cards to be installed (card by card) • ESC X4 Quick Delete • Enter programming mode • 02 Enter • 01 Enter • 05 Enter • Flash all the cards to be deleted (card by card) • ESC X4 Reset Card Pin • Enter programming mode • 02 Enter • 01 Enter • 06 Enter • Key in the card number that need to perform pin reset (6 digits) • ESC X3 Reset Lockout • Enter programming mode • 02 Enter • 01 Enter • 07 Enter • 1 Enter • ESC X3
Reset Lockout Time • Enter programming mode • 02 Enter • 01 Enter • 08 Enter • Key in the reset lockout Gme (HHMM) • ESC X3 Total Card • Enter programming mode • 02 Enter • 01 Enter • 09 Enter • ESC X3 TransacGon • Enter programming mode • 02 Enter • 02 Enter • Press F3 bu>on to view the next transacGon event or F1 bu>on to go back to previous transacGon event • ESC X3 Info Menu • Enter programming mode • 03 Enter • ESC X2
Admin Pin • Enter programming mode • 01 Enter • 01 Enter • 01 Enter • Key in new admin pin (6 digits) • ESC X3 Normal Pin • Enter programming mode • 01 Enter • 01 Enter • 02 Enter • Key in new normal pin (6 digits) • ESC X3 Security Level • Enter programming mode • 01 Enter • 01 Enter • 03 Enter • 1 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3 Unit Address • Enter programming mode • 01 Enter • 01 Enter • 04 Enter • Key in the new unit address (00 -‐ 15 sets) • ESC X3 Reader Mode • Enter programming mode • 01 Enter • 01 Enter • 05 Enter • 1 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3
Inhibit Mode • Enter programming mode • 01 Enter • 02 Enter • 01 Enter • 1 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3 Security Mode • Enter programming mode • 01 Enter • 02 Enter • 02 Enter • 0 Enter (Press 1 to set it ON or press 0 to set it OFF) • ESC X3 Door Pin 1 • Enter programming mode • 01 Enter • 02 Enter • 03 Enter • Key in the new door pin (6 digits) • 06 Enter • 01 • ESC X3 Door Pin 2 • Enter programming mode • 01 Enter • 02 Enter • 04 Enter • Key in the new door pin (6 digits) • 07 Enter • 01 • ESC X3
Door Pin 3 • Enter programming mode • 01 Enter • 02 Enter • 05 Enter • Key in the new door pin (6 digits) • 08 Enter • 01 • ESC X3 Door Pin 1 Tz • Enter programming mode • 01 Enter • 02 Enter • 06 Enter • Key in the new door pin Gmezone • ESC X3 Door Pin 2 Tz • Enter programming mode • 01 Enter • 02 Enter • 07 Enter • Key in the new door pin Gmezone • ESC X3 Door Pin 3 Tz • Enter programming mode • 01 Enter • 02 Enter • 08 Enter • Key in the new door pin Gmezone • ESC X3
Model: EP.MINI MINI (10 digit firmware) Programming Mode
24 MINI programming mode for 10 digit firmware does not have site code
Exit Bu]on Tz • Enter programming mode • 01 Enter • 02 Enter • 09 Enter • Key in the new exit bu>on Gmezone • ESC X3 Auto Release Tz • Enter programming mode • 01 Enter • 02 Enter • 10 Enter • Key in the new auto release Gmezone • ESC X3 Release Time • Enter programming mode • 01 Enter • 02 Enter • 11 Enter • Key in the new release Gme (00 – 99) • ESC X3 Open Time • Enter programming mode • 01 Enter • 02 Enter • 12 Enter • Key in the new open Gme (00 – 99) • ESC X3 Pin Trials • Enter programming mode • 01 Enter • 02 Enter • 13 Enter • Key in the new pin trials (00 – 09) • ESC X3 Card+Pin Tz • Enter programming mode
• 01 Enter • 02 Enter • 14 Enter • Key in the new card+pin Gmezone • ESC X3 Date Se^ng • Enter programming mode • 01 Enter • 03 Enter • Key in the new date (DDMMYY) • ESC X2 Time Se^ng • Enter programming mode • 01 Enter • 04 Enter • Key in the new Gme (HHMMSS) • ESC X2 Reset Password • Enter programming mode • 01 Enter • 05 Enter • 01 Enter • ESC X2 Reset Door Data • Enter programming mode • 01 Enter • 05 Enter • 02 Enter • ESC X2 Format Memory • Enter programming mode
• 01 Enter • 05 Enter • 03 Enter • When finish formaong, a beep sound will be heard • ESC X2 Install Card • Enter programming mode • 02 Enter • 01 Enter • 01 Enter • Key in the card number (10 digits) • ESC X3 Delete Card • Enter programming mode • 02 Enter • 01 Enter • 02 Enter • Key in the card number (10 digits) • ESC X3 View Card • Enter programming mode • 02 Enter • 01 Enter • 03 Enter • Key in the card number (10 digits) • ESC X4 Quick Install • Enter programming mode • 02 Enter • 01 Enter • 04 Enter • Flash all the cards to be installed (card by card) • ESC X4
Model: EP.MINI MINI (10 digit firmware) Programming Mode
25 MINI programming mode for 10 digit firmware does not have site code
Model: EP.MINI MINI (10 digit firmware) Programming Mode
26
MINI programming mode for 10 digit firmware does not have site code
Quick Delete • Enter programming mode • 02 Enter • 01 Enter • 05 Enter • Flash all the cards to be deleted (card by card) • ESC X4 Reset Card Pin • Enter programming mode • 02 Enter • 01 Enter • 06 Enter • Key in the card number that need to perform pin reset (10 digits) • ESC X3 Reset Lockout • Enter programming mode • 02 Enter • 01 Enter • 07 Enter • 1 Enter • ESC X3 Reset Lockout Time • Enter programming mode • 02 Enter • 01 Enter • 08 Enter • Key in the reset lockout Gme (HHMM) • ESC X3 Total Card • Enter programming mode • 02 Enter • 01 Enter • 09 Enter • ESC X3 TransacGon
• Enter programming mode • 02 Enter • 02 Enter • Press F3 bu>on to view the next transacGon event or F1 bu>on to go back to previous transacGon event • ESC X3 Info Menu • Enter programming mode • 03 Enter • ESC X2
Model: EP.MINI
Advisable to perform format memory for the first Gme you turn
on the power
To configure the EP.MINI unit address if there is more than 1 MINI controller
connected to the PC communicator
Cabling InformaGon
CommunicaGon Data Signal Max Distance DescripGon
MINI to ELC 10m (30 W)
22 AWG, 3 Pairs, Shielded
Computer to PC Communicator
RS 232 10m (30 W)
22 AWG, 2 Pairs, Shielded
PC Communicator to MINI
RS 485 1000m (3000 W)
22 AWG, 2 Pairs, Shielded
MINI to exit reader Wiegand 10m (30 W)
22 AWG, 2 Pairs, Shielded
ELC to Electro-‐MagneGc Lock
Power 30m (100 W)
18 AWG, 1 Pair
ELC to Push Bu>on Contact 30m (100 W)
22AWG, 1 Pair
MINI to Door Sensor Contact 30m (100 W)
22AWG, 1 Pair
27