Wiring Accessories Consumer Units Circuit ProtectionRCD Incomer Consumer Units The M2 range of RCD...
Transcript of Wiring Accessories Consumer Units Circuit ProtectionRCD Incomer Consumer Units The M2 range of RCD...
-
Installation Materials Division...the name behind the brands
PR
OD
UC
TC
ATA
LOG
UE
Wiring Accessories
Consumer Units
Circuit Protection
®
M2
EL
EC
TR
ICA
L
-
2
Welcome to......
M2 Electrical
-
Introduction
M2Electrical
01527 520 678
www.m2electrical.co.uk
M2 consumer units, circuit protection devices and soft edge wiring accessories have been designed to be both stylish and practical for the modern home or commercial office.
Consumer units manufactured to the latest wiring regulations feature innovative products such as the compact RCBO and patented designs as incorporated in the mains isolator.
Wiring accessories now include USB charging points on socket outlets and the contemporary white moulded range is complemented by a comprehensive array of decorative metal plate products that also include voice, audio and data combinations.
A new range of IP66 weatherproof accessories are introduced with 20 amp rated switches and enclosures that will accept standard one and two gang accessory products.
-
Metalclad Consumer Units.......................6Insulated Consumer Units.....................14Accessories........................................16Circuit Protection Devices......................18Technical Information.............................22
230v Switchgear Wiring Accessories
Content
IP67 Rotary Isolators..............................20
400v Switchgear
Decorative Accessories.........................28White Moulded Accessories...................44Metalclad Accessories...........................58Weatherproof Accessories....................60Part M Accessories.................................62Medical Sockets....................................64Technical Information............................65
2
-
ConsumerUnits & Circuit Protection Devices
M2 offer a comprehensive range of consumer units and short circuit protective devices for the domestic market that have many features to aid the installation. The dual screw main switch isolator offer unrivalled performance for meter tails connections, whilst the unique bus bar system provide quick and easy installation of devices. In addition, our extensive range of compact RCBO devices now feature a 45 Amp rated device. At M2, it is a matter of safety and our product features and benefits have been developed following research carried out by leading industry bodies. Our commitment to change has been a deciding factor for many esteemed housing associations to choose M2 as their primary switchgear manufacturer.
3
-
+44 (0) 1527 5206784
Con
sum
er U
nits
Selection and Configurations
Isolator Controlled Board
DPISOLATOR
N
NLSupply
E
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
DPRCD
N
NLSupply
E
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
• Allows the use of single module RCBO devices for individual circuit protection at 30mA.
• Reduces risk of nuisance tripping.• An earth fault on one circuit would not adversely
affect other circuits in the installation.• Can be used as main domestic Consumer Unit.
• Suitable for Grouped Circuit Protection of small numbers of circuits, usually downstream of main consumer unit.
• Typical applications include garages, showers and small extensions.
• If fed from main Consumer Unit also with RCD protection then earth leakage discrimination must be considered.
• Can be used as sub-distribution board, but should not be used as main domestic Consumer Unit.
BS7671:2008 incorporating Amendment 3 is clear about the type of enclosure required for domestic (household) premises – non-combustible (or metal) – but the configuration can vary depending on the type of
installation. M2 offers a full selection of consumer units to meet both the requirements of BS7671 and each individual application.
This guide to Consumer Units has been compiled in order to assist in understanding the new wiring regulations. However it is not intended to be a substitute for BS7671:2008 which should always be consulted in order to ensure that all installations are constructed in accordance with these regulations.
- Is the Consumer unit being installed in a domestic (household) premise.
(Reg. 421.1.201) i.e metalclad consumer unit.
- To avoid hazards and minimise inconvenience in the event of a fault. Take into account the
danger caused by failure of a single circuit such as a lighting circuit. Reduce the possibility of tripping of an RCD due to excessive protective conductor currents (Reg. 314.1).
- Socket outlets up to 20A must be protected by a residual-current device (Reg. 411.3.3).
- All circuits containing a bath or shower must be RCD-protected (Reg. 701.411.3.3).
- Unprotected cables buried less than 50mm deep in a wall must be RCDprotected. (Reg. 522.6.202 & 522.6.203).
RCD Controlled Board
See page 8 for Metalclad boards (14 for insulated boards)
See page 9 for Metalclad boards (15 for insulated boards)
-
www.m2electrical.co.uk 5
M2
Con
sum
er U
nits
Selection and Configurations
DPISOLATOR
DPRCD
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
MCB
MCB
MCB
MCB
MCB
MCB
NL
MainsSupply
NL
N1N2
N2
E
Split Load Board
DPISOLATOR
DPRCD
DPRCD
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
NL
MainsSupply
NL NL
N1N2
N2 N1
E
DPISOLATOR
DPRCD
DPRCD
MCB
MCB
MCB
MCB
MCB
MCB
MCB
MCB
NL
MainsSupply
NL NL
N1N2N3
N3 N2
RCBO / M
CB
RCBO / M
CB
E
Dual RCD Board
High Integrity Dual RCD Board
• Offers both High Integrity ways of Isolator and Grouped Circuit Protection off RCD device.
• Unwanted tripping is limited / restricted.• Variable units allow for increased High Integrity
ways for dedicated circuit protection - e.g. Smoke Alarms.
• Can be used as main domestic Consumer Unit.
• High Integrity circuit ways off the isolator are available for dedicated circuit protection - i.e. Smoke Alarms.
• Dual 30mA RCD configuration offering Grouped Circuit Protection.
• Circuits can be segregated to reduce unwanted tripping.
• Can be used as main domestic Consumer Unit.
• Offers Grouped Circuit Protection using two 30mA RCDs
• Circuits can be segregated to reduce unwanted tripping, for example upstairs lights + downstairs ring main off RCD1 and downstairs lights + upstairs ring main off RCD2.
• Can be used as main domestic Consumer Unit.
NSupply
L2Supply
L1Supply
DPISOLATOR
NE
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
RCBO / M
CB
DPISOLATOR
NN
Dual Tariff Board
• For segregation of On Peak and Off Peak circuits.
• Optional split load and isolator incomer options available.
• Additional configurations available upon request.• Can be used as main domestic Consumer Unit.
See page 11 for Metalclad boards
See page 10 for Metalclad boards
See page 10 for Metalclad boards
See page 11 for Metalclad boards
-
+44 (0) 1527 5206786
This new range of Metalclad Consumer Unit from M2 Electrical has been designed in conjunction with contractors and housing authorities specifically to meet the requirements of Regulation 421.1.201 of BS7671:2008 incorporating Amendment 3:2015.
The M2 XS dual screw terminal isolator with a 35mm2 terminal capacity offers protection for nearly double the average strip length, improving cable contact within the terminal and its circular terminal design reduces cable strand spread.
Met
alcl
ad C
onsu
mer
Uni
tsFeatures & Benefits
Steel cam lock with optional retrofit key lock.
5
Preformed internal cable links2
Large rear knockouts with radius corners.
3
Comb bus bar / Half Din Rail for quick fitting of devices.
4
Bespoke consumer units made to order.10
Captive screws with cage nut fixings.6
Full metal enclosure compliant to BS7671 Amendment 3:2015, Reg. 421.1.201 and BS EN 61439-3 compliant..
7
NEW compact 220mm high consumer units.
8
Easy access for meter tail connections.9
1 Dual screw termination.
AM2XRange
-
www.m2electrical.co.uk 7
M2With its linear design and matte white (RAL9010) finish,
the consumer unit offers the home owner a discreet and contemporary product, whilst providing suitable protection to meet today’s need.Regulation 421.1.201 calls for switchgear assemblies,
Met
alcl
ad C
onsu
mer
Uni
ts
Features & Benefitsincluding consumer units, to be housed in a non-combustible enclosure, incorporating the base, cover, door and any accessories. The M2XS range meets these requirements and offers additional features providing a more versatile product.
6
23
4
5
Dual screw termination1
-
+44 (0) 1527 5206788
Met
alcl
ad C
onsu
mer
Uni
tsIsolator Incomer Consumer Units
AM2X16MU Outgoing Ways
Isolator Rating
RCD 1 Rating
RCD 2 Rating
Cat. No. H (mm) W (mm) D (mm)
2 63A - - AM2X2MU 232 149 110
4 100A - - AM2X4MU 220 201 110
6 100A - - AM2X6MU 220 273 110
8 100A - - AM2X8MU 220 273 110
10 100A - - AM2X10MU 220 309 110
11 100A - - AM2X11MU 220 335 110
12 100A - - AM2X12MU 220 381 110
14 100A - - AM2X14MU 220 381 110
16 100A - - AM2X16MU 220 417 110
20 100A - - AM2X20MU 220 489 110
22 100A - - AM2X22M* 440 309 110
26 100A - - AM2X26MU 220 597 110
30 100A - - AM2X30M* 440 381 110
34 100A - - AM2X34M* 440 417 110
Isolator Controlled Consumer Units
The M2 range of metal consumer units are designed and manufactured to BSEN61439 pt 3 and meets the requirements of BS7671:2008, Amendment 3:2015, regulation 421.1.201 - effects against thermal influences specifically for domestic household dwellings.
Manufactured from steel and finished in a polyester powder coating to RAL9010, the M2 range provides a comprehensive selection of products to meet the customers requirements.
Outgoing MCBs/RCBOs to be ordered separately.* - Double banked unit.
-
www.m2electrical.co.uk 9
M2
Met
alcl
ad C
onsu
mer
Uni
ts
RCD Incomer Consumer Units
Outgoing Ways
Isolator Rating
RCD 1 Rating*
RCD 2 Rating*
Cat. No. H (mm) W (mm) D (mm)
2 - 63A - AM2R632M 232 149 110
4 - 63A - AM2R634MU 220 201 110
6 - 63A - AM2R636MU 220 273 110
8 - 63A - AM2R638MU 220 273 110
12 - 63A - AM2R6312MU 220 381 110
2 - 80A - AM2R802M 232 149 110
4 - 80A - AM2R804MU 220 201 110
6 - 80A - AM2R806MU 220 273 110
8 - 80A - AM2R808MU 220 273 110
12 - 80A - AM2R8012MU 220 381 110
4 - 100A - AM2R1004MU 220 201 110
6 - 100A - AM2R1006MU 220 273 110
8 - 100A - AM2R1008MU 220 273 110
12 - 100A - AM2R10012MU 220 381 110
AM2R8012MU
* - 30mA trip rating.
RCD Incomer Consumer Units
The M2 range of RCD incomer metalclad consumer units are available with 63A, 80A and 100A RCD incomer ratings and 30mA earth leakage protection.
For 100mA earth leakage protection, please contact our sales office for further details.
Outgoing MCBs/RCBOs to be ordered separately.
-
+44 (0) 1527 52067810
Dual RCD & Split Load Consumer Units
Split Load Consumer Units
AM2X33TRMU
Outgoing Ways
Isolator Rating
RCD 1 Rating*
RCD 2 Rating*
Cat. No. H (mm) W (mm) D (mm)
6 100A 63A - AM2XSLV6MU 220 273 110
12 100A 63A - AM2XSLV12MU 220 381 110
Outgoing Ways
Isolator Rating
RCD 1 Rating*
RCD 2 Rating*
Cat. No. H (mm) W (mm) D (mm)
6 100A 63A 63A AM2X33TRMU 220 309 110
10 100A 63A 63A AM2X55TRMU 220 381 110
12 100A 80A 80A AM2X66TRMU 220 417 110
16 100A 80A 80A AM2X88TRMU 220 489 110
20 100A 80A 80A AM2X1010TRMU 220 597 110
AM2XSLV12MU
* - 30mA trip rating.
* - 30mA trip rating.
Dual RCD Consumer Units
This selection of consumer units offer the facility to spread the load circuits across one or two 30mA RCDs. Standard configurations listed below supplied with DP
isolator and RCD/s factory fitted, link leads for both live and neutral connections also pre-installed.
Outgoing MCBs/RCBOs to be ordered separately.
Outgoing MCBs/RCBOs to be ordered separately.
Met
alcl
ad C
onsu
mer
Uni
ts
-
www.m2electrical.co.uk 11
M2
Met
alcl
ad C
onsu
mer
Uni
ts
High Integrity Dual RCD Consumer UnitsAM2X55TR2MU Outgoing
WaysIsolator Rating
RCD 1 Rating*
RCD 2 Rating*
Cat. No. H (mm) W (mm) D (mm)
6 100A 63A 63A AM2X23TR1MU 220 309 110
10 100A 63A 63A AM2X44TR2MU 220 381 110
12 100A 63A 63A AM2X55TR2MU 220 417 110
14 100A 63A 63A AM2X66TR2MU 220 489 110
20 100A 80A 80A AM2X88TR4MU 220 597 110
6 100A 63A 63A AM2XDSLV6U 220 309 110
10 100A 63A 63A AM2XDSLV10U 220 381 110
12 100A 80A 80A AM2XDSLV12U 220 417 110
16 100A 80A 80A AM2XDSLV16U 220 489 110
22 100A 80A 80A AM2XDSLV22U 220 597 110
* - 30mA trip rating.Outgoing MCBs/RCBOs to be ordered separately.
High Integrity & Dual Tariff Consumer UnitsFor applications where ‘High Integrity’ circuit protection is required, for example smoke detectors, these units allow dedicated RCBO installation.
Our standard range of dual tariff consumer units provide dedicated segregation of on peak and off peak circuits.
On Peak Off Peak Cat. No. H (mm) W (mm) D (mm)100A isolator 6 ways 100A isolator 2 ways AM2X6DT2U 256 309 110
100A isolator 6 ways 100A isolator 6 ways AM2X6DT6U 256 381 110
100A isolator 8 ways 100A isolator 4 ways AM2X8DT4U 256 381 110
100A isolator 8 ways 100A isolator 6 ways AM2X8DT6U 256 417 110
100A isolator 10 ways 100A isolator 4 ways AM2X10DT4U 256 417 110
100A isolator 12 ways 100A isolator 4 ways AM2X12DT4U 256 446 110
100A isolator 12 ways 100A isolator 6 ways AM2X12DT6U 256 489 110
100A isolator 10 ways 100A isolator 10 ways AM2X10DT10U 500 309 110
3 & 3 Dual RCD 100A isolator 2 ways AM2X33DT2U 256 381 110
4 & 4 Dual RCD 100A isolator 4 ways AM2X44DT4U 256 446 110
5 & 5 Dual RCD 100A isolator 4 ways AM2X55DT4U 256 489 110
AM2X6DT6U Dual Tariff Consumer Units
Other configurations available upon request, please speak to our sales office.
-
+44 (0) 1527 52067812
Met
alcl
ad C
onsu
mer
Uni
tsMetalclad AccessoriesTo compliment the M2 range of metalclad consumer units, a selection of spacer mounts are available for use where retrofitting to surface mount cables are necessary.
In addition, meter tail glands are available for providing Class II insulation protection for incoming supply cables.
Description Cat. No. Dia (mm)Meter tail gland pack (2x16mm / 1x 10mm) M32 - brass MTGP32B 32
Meter tail gland pack (2x25mm / 1x 16mm) M40 - brass MTGP40B 40
Meter tail gland pack (2x16mm / 1x 10mm) M32 - plastic MTGP32P 32
Meter tail gland pack (2x25mm / 1x 16mm) M40 - plastic MTGP40P 40
Meter Tail Gland Pack
MTGP40B
Description Cat. No.Key Operated Lock Assembly AKL
Intumescent putty pad (210mm x 148mm x 3mm) IP21X15
AKL
Safety Accessories
No. of Modules
Banks Cat. No. H (mm) W (mm) D (mm)
6 1 ASM6U 220 201 20
10 1 ASM10U 220 273 20
12 1 ASM12U 220 309 20
16 1 ASM16U 220 381 20
18 1 ASM18U 220 417 20
22 1 ASM22U 220 489 20
28 1 ASM28U 220 597 20
Consumer Unit Spacer Mounts
ASM16U
Outgoing Ways
RCD 1 Rating*
MCB Rating*
Cat. No. H (mm) W (mm) D (mm)
2 40A 6A + 16A AM2GU 232 150 110
4 40A 6A + 16A AM2GU4 220 201 110
1 40A 40A AM2SU95 232 150 110
1 63A 50A AM2SU115 232 150 110
Garage & Shower Units
Outgoing MCBs/RCBOs to be ordered separately.
AM2GU
-
www.m2electrical.co.uk 13
M2
Cas
e S
tudy
Bolton at HomeBespoke M2 Consumer Units
Senior engineers from Bolton at Home, a registered charity providing social housing met with M2 Electrical sales representatives to outline their
needs for servicing 18,000 homes in the borough.
Bolton at Home required a bespoke-sized consumer unit with lift up lid for 200 properties and they were impressed by the prospect of M2’s patented dual screw isolator – the key reasoning being the heightened safety aspect
of the device, to ensure the protection of its residents’ well-being.Furthermore, to maximise space available, Bolton at Home took up the option of utilising M2 Compact RCBOs, ensuring a neat and tidy install.
-
+44 (0) 1527 52067814
Insu
late
d C
onsu
mer
Uni
tsIsolator Incomer Consumer Units
Isolator Controlled Consumer UnitsM2X10I
Outgoing MCBs/RCBOs to be ordered separately.
Outgoing Ways
Isolator Rating (A)
No. of Modules
Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)
1 45 4 M2X1I 230 116 110 220
2 63 4 M2X2I 230 116 110 220
3 63 6 M2X3I 230 152 110 220
4 100 6 M2X4I 230 152 110 220
8 100 12 M2X8I 230 285 110 220
10 100 12 M2X10I 230 285 110 220
14 100 18 M2X14I 230 390 110 220
16 100 18 M2X16I 230 390 110 220
21 100 25 M2X21I 230 511 110 220
23 100 25 M2X23I 230 511 110 220
Readily available from 1 to 23 usable ways, our isolator incomer consumer units allow the use of single module RCBO devices for individual circuit protection at 30mA, reducing the risk of nuisance tripping. Our ranges of isolator incomer consumer units are pre-fitted with a
unique dual screw terminal double-pole mains isolator switch for an increased level of consumer safety, with ratings ranging from 45A – 100A. Our insulated enclosures are manufactured from light grey impact resistant and flame retardant thermoplastic.
-
www.m2electrical.co.uk 15
M2
Insu
late
d C
onsu
mer
Uni
ts
Readily available from 1 to 10 usable ways, our RCD incomer consumer units are suitable for grouped circuit protection for a small number of circuits, typically installed in addition to a property’s main consumer
unit – applications such as garages, showers and small extensions. Our ranges of RCD incomer consumer units are pre-fitted with a 30mA RCD incomer, with ratings ranging from 40A – 100A.
RCD Controlled Consumer Units
RCD Controlled Consumer Units
M2R808
Outgoing Ways
RCD Rating (A)
No. of Modules
Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)
2 40 4 M2R402 230 116 110 220
2 63 4 M2R632 230 116 110 220
4 63 6 M2R634 230 152 110 220
8 63 12 M2R638 230 285 110 220
4 80 6 M2R804 230 152 110 220
8 80 12 M2R808 230 285 110 220
10 80 12 M2R8010 230 285 110 220
8 100 12 M2R1008 230 285 110 220
10 100 12 M2R10010 230 285 110 220Outgoing MCBs/RCBOs to be ordered separately.
Build your own consumer unit or multi-purpose board. Just clip on your required equipment to the DIN Rail and if necessary fit the Comb Busbar. Fitted with full DIN rail, Earth and Neutral terminal bars.
Din Rail EnclosuresM2E18No. of Modules Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)
4 M2E4 230 116 110 220
6 M2E6 230 152 110 220
12 M2E12 230 285 110 220
18 M2E18 230 390 110 220
25 M2E25 230 511 110 220
Outgoing MCBs/RCBOs to be ordered separately.
-
+44 (0) 1527 52067816
Acc
esso
ries
Accessories
Description Cat. No.Blanking plate B1
Insulated Comb Busbars
Barriers & Locking
BM1
DLPX1
DLPX1P
B1
Description Cat. No.Insulated comb busbar 19 SP ways CB19SP
Insulated comb busbar 28 SP ways CB28SP
CB19SP
Description Cat. No.Blanking module BM1
Description Cat. No.MCB Dolly locking device DLPX1
Description Cat. No.MCB Dolly locking device c/w padlock DLPX1P
Description Cat. No.Busbar terminal shroud BBS1
BBS1
Description Cat. No.Cable terminal for insulated comb busbar CBCT1
CBC3
-
www.m2electrical.co.uk 17
M2
Cas
e S
tudy
Waveney District CouncilM2 Consumer Units & Wiring Accessories
Waveney District Council selected M2 XS Amendment 3 consumer units and M2 white moulded wiring accessories for their local housing
specifications. Since specifying M2 Electrical, Waveney District Council can now purchase their very own, branded Consumer Unit - a 10-way Dual
RCD unit, complete with Miniature Circuit Breaker’s and accompanying 16-module Spacer Mount.
Waveney District Council’s previous supplier had a drop in quality and service levels, which prompted them to make a change – with
approximately 5,000 properties to work on. The Council had the opportunity to work with a British manufacturer offering a 25 year
guarantee, based in Worcestershire. M2 Electrical were able to offer a more modern and stylish product than previously installed, which was the
key selling point to the engineers.
-
+44 (0) 1527 52067818
Current Rating (A) 6kA SP Type BCat. No.
6kA SP Type CCat. No.
6 M2B6 M2C6
10 M2B10 M2C10
16 M2B16 M2C16
20 M2B20 M2C20
32 M2B32 M2C32
40 M2B40 M2C40
50 M2B50 M2C50
63 M2B63 M2C63
Circ
uit P
rote
ctio
n D
evic
esMCBs, RCBOs & Compact RCBOs
M2B32
Compact Residual Current Breakers with Overload
M240MBRSP
Miniature Circuit Breakers
M26MBRSPK
Current Rating (A) 6kA Type BCat. No.
6kA Type CCat No.
6 M26MBRSPK M26MCRSPK
10 M210MBRSPK M210MCRSPK
16 M216MBRSPK M216MCRSPK
20 M220MBRSPK M220MCRSPK
32 M232MBRSPK M232MCRSPK
40 M240MBRSPK M240MCRSPK
45 M245MBRSPK M245MCRSPK
Residual Current Breakers with OverloadCurrent Rating (A) 6kA Type B
Cat. No.6kA Type CCat No.
6 M26MBRSP M26MCRSP
10 M210MBRSP M210MBCSP
16 M216MBRSP M216MCRSP
20 M220MBRSP M220MCRSP
32 M232MBRSP M232MCRSP
40 M240MBRSP M240MCRSP
45 M245MBRSP -
-
www.m2electrical.co.uk 19
M2
Circ
uit P
rote
ctio
n D
evic
es
RCDs & Isolators
M2XS45
Isolators
M21002100
Residual Current Devices
Lower current rated DP RCD units are available in Type A on request.
Current rating (A) M2XS45 M2XS45
63 M2XS63
100 M2XS100
Current Rating (A)
No. Of Poles
Max. CableSize
30mA Type AC Cat. No.
30mA Type A Cat. No.
100mA Type AC Cat. No.
32 2 50mm2 M232230 - M2322100
40 2 50mm2 M240230 M240230A M2402100
63 2 50mm2 M263230 M263230A M2632100
80 2 50mm2 M280230 M280230A M2802100
100 2 50mm2 M2100230 M2100230A M21002100
-
+44 (0) 1527 52067820
IP67
Rot
ary
Isol
ator
sRotary Isolators
3 Pole IP67 Rotary IsolatorsCurrent Rating (A) AC23A 415V
Power at 415V (kW)
Power at 690V (kW)
No. of Poles
Max. Cable
Cat. No.
20 11 15 3 10mm2 M2203
32 18.5 15 3 10mm2 M2323
63 37 37 3 35mm2 M2633
100 55 55 3 35mm2 M21003
4 Pole IP67 Rotary IsolatorsCurrent Rating (A) AC23A 415V
Power at 415V (kW)
Power at 690V (kW)
No. of Poles
Max. Cable
Cat. No.
20 11 15 4 10mm2 M2204
32 18.5 15 4 10mm2 M2324
63 37 37 4 35mm2 M2634
100 55 55 4 35mm2 M21004
Product H (mm) W (mm) D (mm)M2203 160 105 127
M2204 160 105 127
M2323 160 105 127
M2324 160 105 127
M2633 210 135 127
M2634 210 135 127
M21003 329 205 154
M21004 329 205 154
M2 Electrical, Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire. B98 0HU. Web: www.m2electrical.co.uk Email: [email protected]
Product Data Sheet
Product Code: M21003 Issue No. Issue Date: Issue by: A 06/10/2017 T. Tombs Description 100A 3 pole switch disconnector with neutral and earth clamps in IP67 insulated enclosure. Key Dimensions
Fixing centres.
Additional information. Usage Intended for use by skilled persons or instructed persons. Electrical Earth & Neutral terminals Rated frequency: 50 / 60 Hz. Rated operational voltage: 690V ac maximum Rated insulation voltage (Ui): 800V Rated impulse voltage (U imp): 8 kV Earthing system: EMC environment: Environment type A. Physical Ambient operating temperature -25 to 40 °C. These isolators should not be operated when submerged. Maximum altitude: 3000m. Enclosure: Glass fibre reinforced polyester. Installation Service conditions: Wiring of this product must comply with current IEE regulations. Units are intended for indoor use and NOT where high levels of humidity and temperature are experienced. Note: IP rating of enclosures can be compromised if correct use of glands is not followed when installing unit. IP67 definition: 6 - Completely protected against dust ingress. 7 - Temporary protection against immersion in water up to 1m depth (water must not penetrate in harmful quantities in prescribed conditions).
M2 Electrical, Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire. B98 0HU. Web: www.m2electrical.co.uk Email: [email protected]
Product Data Sheet
Product Code: M21003 Issue No. Issue Date: Issue by: A 06/10/2017 T. Tombs Description 100A 3 pole switch disconnector with neutral and earth clamps in IP67 insulated enclosure. Key Dimensions
Fixing centres.
Additional information. Usage Intended for use by skilled persons or instructed persons. Electrical Earth & Neutral terminals Rated frequency: 50 / 60 Hz. Rated operational voltage: 690V ac maximum Rated insulation voltage (Ui): 800V Rated impulse voltage (U imp): 8 kV Earthing system: EMC environment: Environment type A. Physical Ambient operating temperature -25 to 40 °C. These isolators should not be operated when submerged. Maximum altitude: 3000m. Enclosure: Glass fibre reinforced polyester. Installation Service conditions: Wiring of this product must comply with current IEE regulations. Units are intended for indoor use and NOT where high levels of humidity and temperature are experienced. Note: IP rating of enclosures can be compromised if correct use of glands is not followed when installing unit. IP67 definition: 6 - Completely protected against dust ingress. 7 - Temporary protection against immersion in water up to 1m depth (water must not penetrate in harmful quantities in prescribed conditions).
H
W D
-
www.m2electrical.co.uk 21
M2
IP67
Rot
ary
Isol
ator
s
Technical Information
- Modern design and manufacturing process. - IP67 ingress protection allows installation in the most
severe conditions. - Dedicated LOCK OFF position. - High switching capability. - Strong high impact resistance enclosure.
Standard BSEN 60947 - 1 & 3. EN 60529
Voltage Rating 690V ac maximum
Enclosure Glass fibre reinforced unsaturated polyester resin. High flame resistance and anti-carbonisation. (PC + ABS)
Handle 2 Padlock positions in the LOCK OFF position. Padlock not supplied.
IP Rating Enclosure - IP67 & switch terminal - IP20
Impact Resistance IK08
Pollution Degree 3
Operating Temperature -25°C to 40°C
Front Cover Screw fixed cover. 2 screws have sealing facility. Captive cover screws
Equipment Type Fixed stationary
Device Rating3 / 4 Pole switch disconnector 20A, 32A 63A or 100A
Accessories. Ordered separately. Change over auxiliary contact. Part No.: M2A11
Auxiliary contact rating: AC-13 - 10A @ 230V ac. AC-15 - 6A @ 230V ac.
1 3 5
L1 L2 L3
E
2 4 6
T1 T2 T3
N
1 3 5
L1 L2 L3
E
2 4 6
T1 T2 T3
7
L4
8
T4
Rotary Isolators
Features
General Characteristics
Switch Configuration
3 Pole 4 Pole
-
+44 (0) 1527 52067822
Tech
nica
l Inf
orm
atio
nTechnical Information
Type Instantaneous Tripping Range
Circuit Applications
B 3 - 5 Used in domestic situations where maximum sensitivity is required and very little equipment with high start-up current is connected.
C 5 - 10 Suitable for commercial / industrial situations where close protection is not required and start up currents of devices can run upto 5 times rated current for a short period. Where many low voltage lights are used in a domestic situation then, due to the inrush currents of the transformers, type C MCBs may be required to avoid nuisance tripping.
D 10 - 20 Suitable for industrial application where start-up currents may be up to 10 times rated current, for example protection for machines with electric motors fitted, welding units etc.
Miniature Circuit BreakersM2 MCBs are of thermo-magnetic, current limiting type and are available in a range of kA ratings (4.5kA up to 10kA) and operating characteristics (Type B, C and D). A selection of SP (single pole), DP (double pole) and TP (triple pole) options are offered. - All MCBs have a ‘trip free
mechanism’.
12060
20105
21
30
105
210.5
0.20.10.05
0.020.010.005
0.0020.0010.0005
Seco
nds
Min
utes
1 2 3 4 5 6 7 8 10 15 20 30 40 50I / In
B C D
2
3 4 5 6 7 8
1
MCB Tripping Curves
1
2
3
4
5
6
7
8
Steady current value 1.13xIn: t>1hrAll MCBs are capable of carrying full load current continuously (derating factors apply for ambient conditions and no. of circuits within an enclosure).
t = Tripping time
Steady current value 1.45xIn: t
-
www.m2electrical.co.uk 23
M2
Tech
nica
l Inf
orm
atio
n
Technical Information
Switchgear Derating
Terminal Capacities
MCB Installation Currents
Table A: Recommended MCB current ratings for the protection of cables to single phase 230V a.c. motors.
Generally the MCBs detailed are not intended to provide close overload protection for motors. However they can be employed in conjunction with the customary motor overload current device as an alternative to the isolator/fuse combination. In this condition the MCB will protect the cable to the motor and the motor will be protected by its own protective device.The tables A and B detailed below give recommendations on MCB selection for motor circuits, for C type only.Note: The values of full load current and starting current will approximately be 10% higher at 380/220V ac than the figures
Range of MCBs Capacity (mm2)MCBs 25mm2 (In and Out)
RCBOs 25mm2 (In) ; 10mm2 (Out)
RCDs (
-
+44 (0) 1527 52067824
MCB Installation Voltages
Maximum Earth fault loop impedance (ie Zs ohms) for circuits supplying socket outlets in accordance with BS7671 regulation 411.3.2 at 218.5V (230V x 0.95 Cmin).
At these levels of earth loop impedance, MCBs will provide disconnection times in accordance with BS7671 for circuits supplying socket outlets .
Type B & C 1 pole 230V ACBS7671: 2008 requirements: Electrical installations (17th Edition of the IEE Wiring regulations) specifically identifies Type B and C. Lower earth fault loop impedance’s (Zs) are generally necessary for Type D to achieve the operating times required by regulation 413-02-08. (Maximum Zs is calculated using the formula in the regulations and the characteristics of the circuit breaker). Where the requirement can not be achieved, use of the circuit breakers
as overcurrent protective devices is not precluded, but the use of residual current circuit breakers (RCDs) to provide protection against indirect earth fault condition is implied. Establishment of the value of the earth fault loop impedance (Zs) at the design stage of installation will determine which type of circuit breaker should be used.
Tech
nica
l Inf
orm
atio
nTechnical Information
Device Standard 6A 10A 16A 20A 32A 40A 50A 63AType B BSEN 60898 7.67 4.60 2.88 2.30 1.43 1.15 0.92 0.73
Type C BSEN 60898 3.83 2.30 1.43 1.15 0.72 0.58 0.46 0.36
-
www.m2electrical.co.uk 25
M2
Cas
e S
tudy
Hounslow HomesM2 Consumer Units
The M2 XS range of Consumer Units were specified by Hounslow Homes
due to their aesthetics, proven safety and versatility.Featuring the unique M2XS mains isolator switch with patented twin
terminals, it offers unrivalled performance and connectivity. In addition, the space saving MCB-sized RCBO device ensure ample
wiring space is available whilst providing maximum protection.
-
26
-
27
ElectricalWiringAccessories
M2 soft edge wiring accessories, both stylish and practical for the modern home or commercial office. Suitable to replace traditional products but equally at home in contemporary settings.
Modular design enables the installer to provide solutions to suit exact customer requirements with maximum flexibility. Small details of providing screw head fixing covers and flushed in neons to enable easy cleaning separate the M2 range from others in the category.
Added to the full range of voice, data and media products M2 presents a comprehensive range for the modern living and the working environment.
-
+44 (0) 1527 52067828
Features & Benefits
M2 Decorative Range
M2 Decorative creates a world of functionality and choice with beautiful aesthetic finishes. Five distinctive plate finishes: antique and polished brass; brushed and polished stainless steel and black nickel. A variety of modules can be selected to suit individual requirements.Further choices of white or black moulded plastic inserts, with or without matching metal decorative rocker switches.
Easy to install, a pleasure to use… the only difficulty is making your choice !
2 Choose plate.
3 Populate to suit your installation.
1 Choose module.
1
2
3
Dec
orat
ive
Acc
esso
ries
-
www.m2electrical.co.uk 29
M2
Product Selection
BrushedStainlessSteel
PolishedStainlessSteel
PolishedBrass
AntiqueBrass
BlackNickel
Product Code GuideRange Code Plate Finish Cat. No. Black Insert
M2 PS 1LS2 BK
BS PS PB AB BN
Metal Rocker(if applicable)
MWhen ordering any of the M2 Decorative range, replace ‘--’ in the catalogue number with your desired plate finish.
For example - M2PS1LS2BKAB & BN not available with white insert. D
ecor
ativ
e A
cces
sorie
s
-
+44 (0) 1527 52067830
Switches
2 Way Light SwitchesDescription Cat. No. H (mm) W (mm)1 Gang switch white insert M2’--’1LS2 86 86
1 Gang switch black insert M2’--’1LS2BK 86 86
1 Gang switch metal rocker white insert M2’--’1LS2M 86 86
1 Gang switch metal rocker black insert M2’--’1LS2MBK 86 86
2 Gang switch white insert M2’--’2LS2 86 86
2 Gang switch black insert M2’--’2LS2BK 86 86
2 Gang switch metal rocker white insert M2’--’2LS2M 86 86
2 Gang switch metal rocker black insert M2’--’2LS2MBK 86 86
3 Gang switch white insert M2’--’3LS2 86 86
3 Gang switch black insert M2’--’3LS2BK 86 86
3 Gang switch metal rocker white insert M2’--’3LS2M 86 86
3 Gang switch metal rocker black insert M2’--’3LS2MBK 86 86
4 Gang switch white insert M2’--’4LS2 86 146
4 Gang switch black insert M2’--’4LS2BK 86 146
4 Gang switch metal rocker white insert M2’--’4LS2M 86 146
4 Gang switch metal rocker black insert M2’--’4LS2MBK 86 146
6 Gang switch white insert M2’--’6LS2 86 146
6 Gang switch black insert M2’--’6LS2BK 86 146
6 Gang switch metal rocker white insert M2’--’6LS2M 86 146
6 Gang switch metal rocker black insert M2’--’6LS2MBK 86 146
Intermediate Light Switches
2 Way Retractive SwitchesDescription Cat. No. H (mm) W (mm)1 Gang switch white insert M2’--’1RS2 86 86
1 Gang switch black insert M2’--’1RS2BK 86 86
1 Gang switch metal rocker white insert M2’--’1RS2M 86 86
1 Gang switch metal rocker black insert M2’--’1RS2MBK 86 86
Triple Pole SwitchesDescription Cat. No. H (mm) W (mm)1 Gang switch white insert M2’--’TPS6 86 86
1 Gang switch black insert M2’--’TPS6BK 86 86
1 Gang switch metal rocker white insert M2’--’TPS6M 86 86
1 Gang switch metal rocker black insert M2’--’TPS6MBK 86 86
Brushed Stainless Steel Polished Stainless Steel Polished Brass Antique Brass Black Nickel
BS PS PB AB BN
Flush mount box: 16mm.
M2BS1LS2M
M2PS1NTS
M2ABTPS6BK
M2BN1LS2MBK
Dec
orat
ive
Acc
esso
ries
Description Cat. No. H (mm) W (mm)1 Gang switch white insert M2’--’1NTS 86 86
1 Gang switch black insert M2’--’1NTSBK 86 86
1 Gang switch metal rocker white insert M2’--’1NTSM 86 86
1 Gang switch metal rocker black insert M2’--’1NTSMBK 86 86
-
www.m2electrical.co.uk 31
M2
9 - 150W LED dimmer
Dimmer Switches
LED/CFL Dimmer SwitchesDescription Cat. No. H (mm) W (mm)1 Gang LED/CFL dimmer M2’--’1400DX 86 86
2 Gang LED/CFL dimmer M2’--’2400HDX 86 86
3 Gang LED/CFL dimmer M2’--’3400DX 86 146
250W DimmersDescription Cat. No. H (mm) W (mm)1 Gang 2 way M2’--’1250D 86 86
2 Gang 2 way M2’--’2250D 86 86
3 Gang 2 way M2’--’3250D 86 146
4 Gang 2 way M2’--’4250D 86 146
400W DimmersDescription Cat. No. H (mm) W (mm)1 Gang 2 way M2’--’1400D 86 86
2 Gang 2 way - double plate M2’--’2400D 86 146
2 Gang 2 way - single plate M2’--’2400HD 86 86
3 Gang 2 way M2’--’3400D 86 146
1000W DimmersDescription Cat. No. H (mm) W (mm)1 Gang 2 way - double plate M2’--’11000D 86 146
1 Gang 2 way - single plate M2’--’11000HD 86 86
Flush mount box: 29mm.
M2BS2400HDX
M2PB3400D
M2PS4250D
M2PB11000D
Dec
orat
ive
Acc
esso
ries
-
+44 (0) 1527 52067832
Fused Connection Units
Unswitched Fused Connection UnitsDescription Cat. No. H (mm) W (mm)13A White insert M2’--’13SU 86 86
13A Black insert M2’--’13SUBK 86 86
13A Metal cover white insert M2’--’13SUM 86 86
13A Metal cover black insert M2’--’13SUMBK 86 86
13A Neon white insert M2’--’13SUN 86 86
13A Neon black insert M2’--’13SUNBK 86 86
13A Neon metal cover white insert M2’--’13SUNM 86 86
13A Neon metal cover black insert M2’--’13SUNMBK 86 86
13A Flex outlet white insert M2’--’13SUF 86 86
13A Flex outlet black insert M2’--’13SUFBK 86 86
13A Flex outlet metal cover white insert M2’--’13SUFM 86 86
13A Flex outlet metal cover black insert M2’--’13SUFMBK 86 86
13A Neon & flex outlet white insert M2’--’13SUNF 86 86
13A Neon & flex outlet black insert M2’--’13SUNFBK 86 86
13A Neon flex outlet metal cover white insert M2’--’13SUNFM 86 86
13A Neon flex outlet metal cover black insert M2’--’13SUNFMBK 86 86
Switched Fused Connection UnitsDescription Cat. No. H (mm) W (mm)13A White insert M2’--’13SSU 86 86
13A Black insert M2’--’13SSUBK 86 86
13A Metal rocker white insert M2’--’13SSUM 86 86
13A Metal rocker black insert M2’--’13SSUMBK 86 86
13A Neon white insert M2’--’13SSUN 86 86
13A Neon black insert M2’--’13SSUNBK 86 86
13A Neon metal rocker white insert M2’--’13SSUNM 86 86
13A Neon metal rocker black insert M2’--’13SSUNMBK 86 86
13A Flex outlet white insert M2’--’13SSUF 86 86
13A Flex outlet black insert M2’--’13SSUFBK 86 86
13A Flex outlet metal cover white insert M2’--’13SSUFM 86 86
13A Flex outlet metal cover black insert M2’--’13SSUFMBK 86 86
13A Neon & flex outlet white insert M2’--’13SSUNF 86 86
13A Neon & flex outlet black insert M2’--’13SSUNFBK 86 86
13A Neon flex outlet metal cover white insert M2’--’13SSUNFM 86 86
13A Neon flex outlet metal cover black insert M2’--’13SSUNFMBK 86 86
Flush mount box: 25mm.
Brushed Stainless Steel Polished Stainless Steel Polished Brass Antique Brass Black Nickel
BS PS PB AB BN
M2BN13SUBK
M2BS13SSUMBK
M2PS13SUNFM
M2PB13SSUN
Dec
orat
ive
Acc
esso
ries
-
www.m2electrical.co.uk 33
M2
Socket Outlets
1 Gang Unswitched Socket OutletsDescription Cat. No. H (mm) W (mm)2A White insert M2’--’12S 86 86
2A Black insert M2’--’12SBK 86 86
5A White insert M2’--’15S 86 86
5A Black insert M2’--’15SBK 86 86
1 Gang Switched Socket Outlets
Description Cat. No. H (mm) W (mm)13A DP white insert M2’--’113SSDP 86 86
13A DP black insert M2’--’113SSDPBK 86 86
13A DP metal rocker white insert M2’--’113SSDPM 86 86
13A DP metal rocker black insert M2’--’113SSDPMBK 86 86
2 Gang Switched Socket OutletsDescription Cat. No. H (mm) W (mm)13A DP white insert M2’--’213SSDP 86 146
13A DP black insert M2’--’213SSDPBK 86 146
13A DP metal rocker white insert M2’--’213SSDPM 86 146
13A DP metal rocker black insert M2’--’213SSDPMBK 86 146
Flush mount box: 25mm.
M2PB15S
M2BS213SSDPM
M2PS113SSDPMBK
Dec
orat
ive
Acc
esso
ries
-
+44 (0) 1527 52067834
M2PB213SSUSB
M2PSDVSS
M2BN113SSUSBMBK
Socket Outlets
Dual Voltage Shaver SocketsDescription Cat. No. H (mm) W (mm)Dual voltage shaver socket white insert M2’--’DVSS 146 86
Dual voltage shaver socket black insert M2’--’DVSSBK 146 86
Description Cat. No. H (mm) W (mm)13A 1 Gang USB white insert M2’--’113SSUSB 86 86
13A 1 Gang USB black insert M2’--’113SSUSBBK 86 86
13A 1 Gang USB metal rocker white insert M2’--’113SSUSBM 86 86
13A 1 Gang USB metal rocker black insert M2’--’113SSUSBMBK 86 86
13A 2 Gang USB white insert M2’--’213SSUSB 86 146
13A 2 Gang USB black insert M2’--’213SSUSBBK 86 146
13A 2 Gang USB metal rocker white insert M2’--’213SSUSBM 86 146
13A 2 Gang USB metal rocker black insert M2’--’213SSUSBMBK 86 146
USB Switched Socket Outlets
Flush mount box: 47mm.
Flush mount box: 25mm.
Brushed Stainless Steel Polished Stainless Steel Polished Brass Antique Brass Black Nickel
BS PS PB AB BN
Dec
orat
ive
Acc
esso
ries
-
www.m2electrical.co.uk 35
M2
M2AB20DPSBK
M2BS145S
M2BN20DPSNFMBK
M2BS145SNM
Double Pole Switches
20A Double Pole SwitchesDescription Cat. No. H (mm) W (mm)White insert M2’--’20DPS 86 86
Black insert M2’--’20DPSBK 86 86
Metal rocker white insert M2’--’20DPSM 86 86
Metal rocker black insert M2’--’20DPSMBK 86 86
Neon white insert M2’--’20DPSN 86 86
Neon black insert M2’--’20DPSNBK 86 86
Neon metal rocker white insert M2’--’20DPSNM 86 86
Neon metal rocker black insert M2’--’20DPSNMBK 86 86
Flex outlet white insert M2’--’20DPSF 86 86
Flex outlet black insert M2’--’20DPSFBK 86 86
Flex outlet metal rocker white insert M2’--’20DPSFM 86 86
Flex outlet metal rocker black insert M2’--’20DPSFMBK 86 86
Neon & flex outlet white insert M2’--’20DPSNF 86 86
Neon & flex outlet black insert M2’--’20DPSNFBK 86 86
Neon & flex outlet metal rocker white insert M2’--’20DPSNFM 86 86
Neon & flex outlet metal rocker black insert M2’--’20DPSNFMBK 86 86
Flex outlet white insert M2’--’20FX 86 86
Flex outlet black insert M2’--’20FXBK 86 86
1 Gang 45A Double Pole SwitchesDescription Cat. No. H (mm) W (mm)DP switch white insert M2’--’145S 86 86
DP switch black insert M2’--’145SBK 86 86
DP switch metal rocker white insert M2’--’145SM 86 86
DP switch metal rocker black insert M2’--’145SMBK 86 86
DP switch & neon white insert M2’--’145SN 86 86
DP switch & neon black insert M2’--’145SNBK 86 86
DP switch & neon metal rocker white insert M2’--’145SNM 86 86
DP switch & neon metal rocker black insert
M2’--’145SNMBK 86 86
Flush mount box: 47mm.
Flush mount box: 25mm.
Dec
orat
ive
Acc
esso
ries
-
+44 (0) 1527 52067836
Double Pole Switches & Cooker Panels
2 Gang 45A Cooker PanelsDescription Cat. No. H (mm) W (mm)Cooker control unit white insert M2’--’45CCU 86 146
Cooker control unit black insert M2’--’45CCUBK 86 146
Cooker control unit metal rockers white insert M2’--’45CCUM 86 146
Cooker control unit metal rockers black insert M2’--’45CCUMBK 86 146
Cooker control unit + neon white insert M2’--’45CCN 86 146
Cooker control unit + neon black insert M2’--’45CCNBK 86 146
Cooker control unit + neon metal rockers white insert
M2’--’45CCNM 86 146
Cooker control unit + neon metal rockers black insert
M2’--’45CCNMBK 86 146
2 Gang 45A Double Pole SwitchesDescription Cat. No. H (mm) W (mm)DP switch white insert M2’--’245S 146 86
DP switch black insert M2’--’245SBK 146 86
DP switch metal rocker white insert M2’--’245SM 146 86
DP switch metal rocker black insert M2’--’245SMBK 146 86
DP switch & neon white insert M2’--’245SN 146 86
DP switch & neon black insert M2’--’245SNBK 146 86
DP switch & neon metal rocker white insert M2’--’245SNM 146 86
DP switch & neon metal rocker black insert
M2’--’245SNMBK 146 86
Flush mount box: 47mm.
Brushed Stainless Steel Polished Stainless Steel Polished Brass Antique Brass Black Nickel
BS PS PB AB BN
M2PS45CCNMBK
M2BS245SM
M2PB45CCU
Dec
orat
ive
Acc
esso
ries
-
www.m2electrical.co.uk 37
M2
TV OutletsDescription Cat. No. H (mm) W (mm)1 Gang coaxial socket white insert M2’--’1TV 86 86
1 Gang coaxial socket black insert M2’--’1TVBK 86 86
1 Gang coaxial isolated socket white insert M2’--’1TVISO 86 86
1 Gang coaxial isolated socket black insert M2’--’1TVISOBK 86 86
1 Gang satellite socket white insert M2’--’1SAT 86 86
1 Gang satellite socket black insert M2’--’1SATBK 86 86
1 Gang coaxial & satellite socket white insert M2’--’1TV/SAT 86 86
1 Gang coaxial & satellite socket black insert M2’--’1TV/SATBK 86 86
2 Gang coaxial socket white insert M2’--’2TV 86 86
2 Gang coaxial socket black insert M2’--’2TVBK 86 86
1 Gang Telephone OutletsDescription Cat. No. H (mm) W (mm)Telephone master white insert M2’--’1TMF 86 86
Telephone master black insert M2’--’1TMFBK 86 86
Telephone secondary white insert M2’--’1TEF 86 86
Telephone secondary black insert M2’--’1TEFBK 86 86
RJ11 Telephone white insert M2’--’1RJ11 86 86
RJ11 Telephone black insert M2’--’1RJ11BK 86 86
1 Gang Data OutletsDescription Cat. No. H (mm) W (mm)CAT5E data outlet white insert M2’--’1RJ5E 86 86
CAT5E data outlet black insert M2’--’1RJ5EBK 86 86
CAT6 data outlet white insert M2’--’1RJ6 86 86
CAT6 data outlet black insert M2’--’1RJ6BK 86 86
Blank PlatesDescription Cat. No. H (mm) W (mm)1 Gang blank plate M2’--’1BP 86 86
2 Gang blank plate M2’--’2BP 86 146
Outlets & Plates
M2BS1TV/SAT
M2AB1BP
M2BN1TEFBK
M2PB1RJ6BK
Dec
orat
ive
Acc
esso
ries
-
+44 (0) 1527 52067838
Modular Plates
1 Gang Modular PlatesDescription Cat. No. H (mm) W (mm)1 Module aperture plate white trim M2’--’SM1G1AP 86 86
1 Module aperture plate black trim M2’--’SM1G1APBK 86 86
2 Module aperture plate white trim M2’--’SM1G2AP 86 86
2 Module aperture plate black trim M2’--’SM1G2APBK 86 86
3 Module aperture plate white trim M2’--’SM1G3AP 86 86
3 Module aperture plate black trim M2’--’SM1G3APBK 86 86
1 Module easyclip plate white trim M2’--’1G1MP 86 86
1 Module easyclip plate black trim M2’--’1G1MPBK 86 86
2 Module easyclip plate white trim M2’--’1G2MP 86 86
2 Module easyclip plate black trim M2’--’1G2MPBK 86 86
2 Gang Modular PlatesDescription Cat. No. H (mm) W (mm)4 Module aperture plate white trim M2’--’SM2G4AP 86 146
4 Module aperture plate black trim M2’--’SM2G4APBK 86 146
6 Module aperture plate white trim M2’--’SM2G6AP 86 146
6 Module aperture plate black trim M2’--’SM2G6APBK 86 146
4 Module easyclip plate white trim M2’--’2G4MP 86 146
4 Module easyclip plate black trim M2’--’2G4MPBK 86 146
Brushed Stainless Steel Polished Stainless Steel Polished Brass Antique Brass Black Nickel
BS PS PB AB BN
M2ABSM1G2APBK
M2PSSM2G4AP
M2BNSM1G3APBK
Easy to swap modules to provide endless combinations and simple solutions.
Dec
orat
ive
Acc
esso
ries
-
www.m2electrical.co.uk 39
M2
M2SM1LS2
Switch Modules
1 Way Light Switch ModulesDescription Cat. No. H (mm) W (mm)White M2SM1LS1 65 16
Black M2SM1LS1BK 65 16
Brushed stainless steel M2SM1LS1MBS 65 16
Polished stainless steel M2SM1LS1MPS 65 16
Polished brass M2SM1LS1MPB 65 16
Antique brass M2SM1LS1MAB 65 16
Black nickel M2SM1LS1MBN 65 16
2 Way Light Switch ModulesDescription Cat. No. H (mm) W (mm)White M2SM1LS2 65 16
Black M2SM1LS2BK 65 16
Brushed stainless steel M2SM1LS2MBS 65 16
Polished stainless steel M2SM1LS2MPS 65 16
Polished brass M2SM1LS2MPB 65 16
Antique brass M2SM1LS2MAB 65 16
Black nickel M2SM1LS2MBN 65 16
Intermediate Switch ModulesDescription Cat. No. H (mm) W (mm)White M2SM1NTS 65 16
Black M2SM1NTSBK 65 16
Brushed stainless steel M2SM1NTSMBS 65 16
Polished stainless steel M2SM1NTSMPS 65 16
Polished brass M2SM1NTSMPB 65 16
Antique brass M2SM1NTSMAB 65 16
Black nickel M2SM1NTSMBN 65 16
1 Way Retractive Switch ModulesDescription Cat. No. H (mm) W (mm)White M2SM1RS1 65 16
Black M2SM1RS1BK 65 16
Brushed stainless steel M2SM1RS1MBS 65 16
Polished stainless steel M2SM1RS1MPS 65 16
Polished brass M2SM1RS1MPB 65 16
Antique brass M2SM1RS1MAB 65 16
Black nickel M2SM1RS1MBN 65 16
M2SM1LS2MBN
M2SM1RS1MAB
M2SM1NTSMPB
Dec
orat
ive
Acc
esso
ries
-
+44 (0) 1527 52067840
Switch & Blank ModulesD
ecor
ativ
e A
cces
sorie
s
2 Way Retractive Switch ModulesDescription Cat. No. H (mm) W (mm)White M2SM1RS2 65 16
Black M2SM1RS2BK 65 16
Brushed stainless steel M2SM1RS2MBS 65 16
Polished stainless steel M2SM1RS2MPS 65 16
Polished brass M2SM1RS2MPB 65 16
Antique brass M2SM1RS2MAB 65 16
Black nickel M2SM1RS2MBN 65 16
Key Switch Modules
Double Pole Switch ModulesDescription Cat. No. H (mm) W (mm)White M2SMDPS 65 16
Black M2SMDPSBK 65 16
Brushed stainless steel M2SMDPSMBS 65 16
Polished stainless steel M2SMDPSMPS 65 16
Polished brass M2SMDPSMPB 65 16
Antique brass M2SMDPSMAB 65 16
Black nickel M2SMDPSMBN 65 16
M2SM1RS2MPB
M2SM1KS2
M2SMDPSMBN
Brushed Stainless Steel Polished Stainless Steel Polished Brass Antique Brass Black Nickel
BS PS PB AB BN
Description Cat. No. H (mm) W (mm)2 way white M2SM1KS2 65 16
2 way black M2SM1KS2BK 65 16
DP white M2SMDPKS 65 16
DP black M2SMDPKSBK 65 16
DP white - printed ‘EMG LTG TEST’ M2SMDPKS/EMG 65 16
DP black - printed ‘EMG LTG TEST’ M2SMDPKSBK/EMG 65 16
M2SM1BP
Blank ModulesDescription Cat. No. H (mm) W (mm)White M2SM1BP 65 16
Black M2SM1BPBK 65 16
Brushed stainless steel M2SM1BPMBS 65 16
Polished stainless steel M2SM1BPMPS 65 16
Polished brass M2SM1BPMPB 65 16
Antique brass M2SM1BPMAB 65 16
Black nickel M2SM1BPMBN 65 16
-
www.m2electrical.co.uk 41
M2
Printing Description Print SuffixKeyswitch module ‘EMG LTG TEST’ EMG
Washing machine WM
Tumble dryer TD
Fridge freezer FF
Waste disposal WD
Microwave MW
Cooker hood CH
Fridge FD
Freezer FZ
Fan FN
Hob HB
Boiler BL
Oven OV
Water heater WH
Dish washer DW
Printed Double Pole Modules
Dec
orat
ive
Acc
esso
ries
Description Cat. No.White No suffix required
Black BK
Brushed stainless steel BS
Polished stainless steel PS
Polished brass PB
Antique brass AB
Black nickel BN
Print Ref.
Module Finishes
M2SMDPSMABWM
M2SMDPSMPBWM
Product Code GuideRange Code Switch Module Type Black Insert
(if applicable)
M2 SM DPS BKWhen ordering any of the M2 Decorative modules, use code above.
Metal Rocker(if applicable)
MPrint Ref.
WMPlate Finish
BS
-
+44 (0) 1527 52067842
M2SM13SUMBS
M2SMDABBS
Dec
orat
ive
Acc
esso
ries
Fuse & Dimmer Modules
Fuse ModulesDescription Cat. No. H (mm) W (mm)White M2SM13SU 65 16
Black M2SM13SUBK 65 16
Brushed stainless steel white insert M2SM13SUMBS 65 16
Brushed stainless steel black insert M2SM13SUMBSBK 65 16
Polished stainless steel white insert M2SM13SUMPS 65 16
Polished stainless steel black insert M2SM13SUMPSBK 65 16
Polished brass white insert M2SM13SUMPB 65 16
Polished brass black insert M2SM13SUMPBBK 65 16
Antique brass M2SM13SUMABBK 65 16
Black nickel M2SM13SUMBNBK 65 16
Dimmer Assembly Modules(Twin module width)
Description Cat. No. H (mm) W (mm)White module, white cap M2SMDAWW 65 32
Black module, black cap M2SMDABB 65 32
White module, brushed stainless steel cap M2SMDAWBS 65 32
Black module, brushed stainless steel cap M2SMDABBS 65 32
White module, polished stainless steel cap M2SMDAWPS 65 32
Black module, polished stainless steel cap M2SMDABPS 65 32
White module, polished brass cap M2SMDAWPB 65 32
Black module, polished brass cap M2SMDABPB 65 32
Black module, antique brass cap M2SMDABAB 65 32
Black module, black nickel cap M2SMDABBN 65 32
Interchangeable Dimmer ModulesDescription Cat. No. H (mm) W (mm)2 Way 250w dimmer module DM2502W - -
2 Way 400w dimmer module DM4002W - -
400w LED/CFL dimmer module DMLED - -
6A 2 Way switch only module DMSO - -DMSO
Flush mount box: 35mm.Set consists of dimmer backing plate, lock nut tool & dimmer cap.
-
www.m2electrical.co.uk 43
M2
Hounslow HomesM2 Wiring Accessories
M2 wiring accessories have been specified through Hounslow Homes to be installed in new build & refurbishment projects. Their electrical engineers were satisfied that the unique colour coded terminals on the M2 range eased installation and required the services of a local
manufacturer to supply the many different engraved spurs that were required on the project.C
ase
Stu
dy
-
+44 (0) 1527 52067844
M2Soft EdgeW
hite
Mou
lded
Acc
esso
ries
Features & Benefits
Switches
- Curved rockers. - Easy switch action. - Modular format for greater flexibility. - Colour matched on 45 amp products.
Thermoset Urea Faceplates
- Soft edge. - High gloss finish. - Scratch resistant. - Flat fronted to ensure correct plug seating.
Screw Cap Covers
- Clean smooth overall appearance. - Tamper proof. - Unbroken surface minimises dust traps.
Power Indication
- Flush mount neon indicator. - Crescent rocker marking.
Fastline
A limited alternative within the M2 range offering choice without compromising quality.
See highlighted products within.
2 Choose plate.
3 Populate to suit your installation.
1 Choose module.
1
2
3
-
www.m2electrical.co.uk 45
M2
Whi
te M
ould
ed A
cces
sorie
s
Features & Benefits
-
+44 (0) 1527 52067846
Light Switches
1 Way Light Switch
M2P2E
M21AS2
M2TPS65SU
Description Cat. No. H (mm) W (mm)1 Gang light switch 1 way M21LS1 86 86
2 Way Light SwitchesDescription Cat. No. H (mm) W (mm)1 Gang light switch 2 way M21LS2 86 86
2 Gang light switch 2 way M22LS2 86 86
3 Gang light switch 2 way M23LS2 86 86
4 Gang light switch 2 way M24LS2 86 146
6 Gang light switch 2 way M26LS2 86 146
Intermediate Light SwitchesDescription Cat. No. H (mm) W (mm)1 Gang light switch intermediate M21NTS 86 86
Retractive SwitchesDescription Cat. No. H (mm) W (mm)6A Retractive switch M26RS 86 86
1 Gang retractive switch 1 way printed ‘PRESS TO EXIT’
M2P2E 86 86
1 Gang retractive switch large rocker 1 way printed ‘DOOR EXIT’
M2DES 86 86
Architrave SwitchesDescription Cat. No. H (mm) W (mm)1 Gang architrave switch 2 way M21AS2 86 32
2 Gang architrave switch 2 way M22AS2 172 32
Triple Pole SwitchesDescription Cat. No. H (mm) W (mm)6A Triple pole switch M2FLTPS6 86 86
6A Triple pole switch fan isolator M2FLTPS6FN 86 86
Triple pole swicth c/w 5A fuse module M2TPS65SU 86 86
M21LS1
M24LS2
M21NTS
Surface mount box: 19mm | Flush mount box: 16mm.
Whi
te M
ould
ed A
cces
sorie
s
-
www.m2electrical.co.uk 47
M2
Modular Switches & Plates
Description Cat. No. H (mm) W (mm)1 Gang 1 module plate M2SM1G1AP 86 86
1 Gang 2 module plate M2SM1G2AP 86 86
1 Gang 3 module plate M2SM1G3AP 86 86
Description Cat. No. H (mm) W (mm)2 Gang 4 module plate M2SM2G4AP 86 146
2 Gang 6 module plate M2SM2G6AP 86 146
1 Gang Plates
2 Gang Plates
M2SM1G2AP
M2SM2G4AP
1 Way Switch Modules
2 Way Switch Modules
Intermediate Switch Module
Description Cat. No. H (mm) W (mm)Switch module 1 way M2SM1LS1 65 16
Keyswitch module 1 way M2SM1KS1 65 16
Retractive switch module 1 way M2SM1RS1 65 16
Description Cat. No. H (mm) W (mm)
Switch module 2 way M2SM1LS2 65 16Keyswitch module 2 way M2SM1KS2 65 16
Retractive switch module 2 way M2SM1RS2 65 16
Description Cat. No. H (mm) W (mm)Intermediate switch module M2SM1NTS 65 16
M2SM1LS1
M2SM1KS2
M2SM1NTS
Double Pole SwitchesDescription Cat. No. H (mm) W (mm)16A Double pole key switch printed ‘EMG LTG TEST’
M2DPKS/EMG 86 86
M2DPKS/EMG
Whi
te M
ould
ed A
cces
sorie
s
-
+44 (0) 1527 52067848
Modular Accessories
Double Pole Switch ModulesDescription Cat. No. H (mm) W (mm)Switch module M2SMDPS 65 16
Retractive switch module M2SMDPRS 65 16
Keyswitch module M2SMDPKS 65 16
Double Pole Switch Modules (Printed)Printing Description Cat. No. H (mm) W (mm)Keyswitch module ‘EMG LTG TEST’ M2SMDPKS/EMG 65 16
Washing machine M2SMDPSWM 65 16
Tumble dryer M2SMDPSTD 65 16
Fridge freezer M2SMDPSFF 65 16
Waste disposal M2SMDPSWD 65 16
Microwave M2SMDPSMW 65 16
Cooker hood M2SMDPSCH 65 16
Fridge M2SMDPSFD 65 16
Freezer M2SMDPSFZ 65 16
Fan M2SMDPSFN 65 16
Hob M2SMDPSHB 65 16
Boiler M2SMDPSBL 65 16
Oven M2SMDPSOV 65 16
Water heater M2SMDPSWH 65 16
Dish washer M2SMDPSDW 65 16
M2SMDPSFF
M2SMDPSBL
M2SMDPKS
Fuse ModuleDescription Cat. No. H (mm) W (mm)13A Fuse module M2SM13SU 65 16
M2SM13SU
Neon Modules & BlankDescription Cat. No. H (mm) W (mm)Red M2SMNIR 65 16
Amber M2SMNIA 65 16
Green M2SMNIG 65 16
Blank module M2SM1BP 65 16M2SMNIG
Whi
te M
ould
ed A
cces
sorie
s
TP Isolator ModuleDescription Cat. No. H (mm) W (mm)Triple pole switch module M2SMTPS6 65 32
M2SMTPS6
-
www.m2electrical.co.uk 49
M2
Dimmer Switches
1 Way Dimmer Switch
Suitable for both mains and low voltage applications and do not require de-rating for GU10 lamps.
Surface mount box: 29mm | Flush mount box: 25mm.Not suitable for switching fluorescent loads.
2 Way Dimmer SwitchesDescription Cat. No. H (mm) W (mm)1 Gang 250w dimmer 2 way M21250D 86 86
1 Gang 400w dimmer 2 way M21400D/2 86 86
2 Gang 250w dimmer 2 way M22250D 86 86
2 Gang 400w dimmer 2 way M22400HD 86 86
2 Gang 400w dimmer 2 way M22400D 86 146
3 Gang 250w dimmer 2 way M23250D 86 146
3 Gang 400w dimmer 2 way M23400D 86 146
4 Gang 250w dimmer 2 way M24250D 86 146
Description Cat. No. H (mm) W (mm)1 Gang 400w dimmer 1 way M21400D/1 86 86
M21400D/1
M22400HD
LED/CFL Dimmer SwitchesDescription Cat. No. H (mm) W (mm)1 Gang 400w dimmer 2 way M21400DX 86 86
2 Gang 400w dimmer 2 way M22400HDX 86 86
3 Gang 400w dimmer 2 way M23400DX 86 146
2 Gang 400w dimmer 2way M22400DX 86 146M23400DX
Dimmer Assembly Modules(Twin module width)
Description Cat. No. H (mm) W (mm)White module, white cap M2SMDAWW 86 32
Interchangeable Dimmer ModulesDescription Cat. No. H (mm) W (mm)2 Way 250w dimmer module DM2502W - -
2 Way 400w dimmer module DM4002W - -
400w LED/CFL dimmer module DMLED - -
6A 2 Way switch only module DMSO - -
Flush mount box: 35mm.Set consists of dimmer backing plate, lock nut tool & dimmer cap.
DMSO
M2SMDAWW
Whi
te M
ould
ed A
cces
sorie
s
-
+44 (0) 1527 52067850
Socket Outlets
Description Cat. No. H (mm) W (mm)13A 1 Gang unswitched socket outlet M2113S 86 86
13A 1 Gang switched socket outlet M2113SS 86 86
13A 1 Gang switched socket outlet c/w neon M2113SSN 86 86
5A 1 Gang unswitched socket outlet M215S 86 86M2113SS
Socket Outlets
13A 2 Gang unswitched socket outlet M2213S 86 146
13A 2 Gang switched socket outlet M2213SS 86 146
13A 2 Gang switched socket outlet (red) M2R213SS* 86 146
2 Gang switched socket + 4 module plate M221336 86 146
13A Neon key switched socket outlet PE5133 86 146M2213SS
Fast Line - Sockets OutletsDescription Cat. No. H (mm) W (mm)13A 1 Gang switched socket outlet - DP M2FL113SSDP 86 86
13A 2 Gang switched socket outlet - DP M2FL213SSDP 86 146
13A 2 Gang switched socket outlet - SP M2FL213SS 86 146
M2FL213SSDP Surface mount box: 29mm | Flush mount box: 25mm.
Shaver OutletDescription Cat. No. H (mm) W (mm)Dual voltage shaver socket 20VA 230V / 115V
M2DVSS 146 86
M2DVSS
Surface mount box: 47mm | Flush mount box: 47mm.
USB Switched Socket OutletsDescription Cat. No. H (mm) W (mm)13A 1 Gang 2 USB switched socket outlet M2113SSUSB 86 86
13A 2 Gang 2 USB switched socket outlet M2213SSUSB 86 146
M2213SSUSB
M2413SS
Socket OutletDescription Cat. No. H (mm) W (mm)13A 4 Gang switched socket outlet c/w back box
M2413SS 86 292
Back Box Dimensions: 276 x 75 x 35mm.
* - Other colours also available
Whi
te M
ould
ed A
cces
sorie
s
-
www.m2electrical.co.uk 51
M2
Connection Units & DP Switches
13A Connection UnitsDescription Cat. No. H (mm) W (mm)13A Unswitched fused connection unit M213SU 86 86
13A DP switched fused connection unit M213SSU 86 86
13A DP switched fused connection unit c/w neon M213SSUN 86 86
13A Red unswitched fused connection unit printed ‘FIRE ALARM’
M2RSUFA 86 86
Description Cat. No. H (mm) W (mm)13A DP switched fused connection unit M2FL13SSU 86 86
13A DP switched fused connection unit c/w neon
M2FL13SSUN 86 86
13A DP switched fused connection unit c/w neon & flex outlet
M2FL13SSUNF 86 86
13A DP switched fused connection unit c/w flex outlet
M2FL13SSUF 86 86
13A Unswitched fused connection unit M2FL13SU 86 86
13A Unswitched fused connection unit c/w neon M2FL13SUN 86 86
13A Unswitched fused connection unit c/w neon & flex outlet
M2FL13SUNF 86 86
13A Unswitched fused connection unit c/w flex outlet
M2FL13SUF 86 86
Fast Line 13A Connection Units
M213SU
M2FL13SSUNF
M2FL13SUN
Surface mount box: 29mm | Flush mount box: 25mm.Bottom edge cable outlet, accepts 2.5mm² flexible cord on specified outlet plates.
Print legends and engraving service available.
M220DPSN
20A Double Pole SwitchesDescription Cat. No. H (mm) W (mm)20A Double pole switch M220DPS 86 86
20A Double pole switch c/w neon M220DPSN 86 86
Fast Line 20A Double Pole SwitchesDescription Cat. No. H (mm) W (mm)20A Double pole switch M2FL20DPS 86 86
20A Double pole switch c/w neon M2FL20DPSN 86 86
20A Double pole switch c/w neon & flex outlet
M2FL20DPSNF 86 86
20A Double pole switch c/w flex outlet M2FL20DPSF 86 86M2FL20DPSNF
M220FX
Flex OutletsDescription Cat. No. H (mm) W (mm)20A Flex outlet M220FX 86 86
20A Flex outlet M2FL20FX 86 86
Whi
te M
ould
ed A
cces
sorie
s
-
+44 (0) 1527 52067852
45A DP Switches & Cooker Panels
45A Double Pole Switches
- Screw Cap Covers for overall clean appearance. - Neon Indicators flushed into plate . - White Rockers.
Description Cat. No. H (mm) W (mm)1 Gang 45A switch M2145S 86 86
1 Gang 45A switch with neon M2145SN 86 86
1 Gang 45A switch M2FL145S 86 86
1 Gang 45A switch with neon M2FL145SN 86 86M2145S
45A Double Pole SwitchesDescription Cat. No. H (mm) W (mm)2 Gang 45A switch M2245S 146 86
2 Gang 45A switch with neon M2245SN 146 86
2 Gang 45A switch M2FL245S 146 86
2 Gang 45A switch with neon M2FL245SN 146 86
M2245SN
Surface mount box: 47mm | Flush mount box: 47mm.
45A Cooker PanelsDescription Cat. No. H (mm) W (mm)45A Cooker control unit M245CCU 86 146
45A Cooker control unit with neon M245CCN 86 146
45A Cooker control unit M2FL45CCU 86 146
45A Cooker control unit with neon M2FL45CCN 86 146M245CCN
Cooker OutletDescription Cat. No. H (mm) W (mm)Cooker outlet M2CO 86 86
Cooker outlet M2FLCO 86 86
M2CO
Whi
te M
ould
ed A
cces
sorie
s
-
www.m2electrical.co.uk 53
M2
Coaxial, Voice & Data
Description Cat. No. H (mm) W (mm)1 Gang satellite connection plate M21SAT 86 86
1 Gang TV outlet M21TV 86 86
1 Gang TV isolated M21TVISO 86 86
1 Gang TV & satellite connector M21TV/SAT 86 86
1 Gang Coaxial & Satellite Sockets
Digital Sockets
Voice & Data Sockets
Description Cat. No. H (mm) W (mm)2 Gang satellite connector 1 gang plate M22SAT 86 86
2 Gang TV outlet non isolated 1 gang plate M22TV 86 86
2 Gang TV socket isolated 1 gang plate M22TV/ISO 86 86
2 Gang Coaxial & Satellite Sockets
Multi-way outlets split a single down feed from a combiner.
Description Cat. No. H (mm) W (mm)TV/FM diplex plate M2DIPLEX 86 86
TV/FM/SAT triplex plate M2TRIPLEX 86 86
TV/FM/ SAT1/SAT2 quad plate M2QUAD 86 86
Description Cat. No. H (mm) W (mm)1 Gang RJ45 data socket M21RJ 86 86
1 Gang RJ11 telephone socket M21RJ11 86 86
1 Gang telephone extension flush fitting M21TEF 86 86
1 Gang telephone master flush fitting M21TMF 86 86
M22TV/ISO
M2QUAD
M21TEF
M21TV/SAT
Surface mount box: 29mm | Flush mount box: 25mm.
Whi
te M
ould
ed A
cces
sorie
s
-
+44 (0) 1527 52067854
Modular Plates
1 Gang PlatesDescription Cat. No. H (mm) W (mm)1 Gang 1 module plate M21G1MP 86 86
1 Gang 2 module plate M21G2MP 86 86
2 Gang PlatesDescription Cat. No. H (mm) W (mm)2 Gang 4 module plate M22G4MP 86 146
4 Gang PlateDescription Cat. No. H (mm) W (mm)4 Gang 8 module linear plate c/w back box M24G8MP 86 292
Back Box Dimensions: 196 x 164 x 47mm.
12 Module EnclosureDescription Cat. No. H (mm) W (mm)12 Module enclosure c/w back box DE374 190 210
Back Box Dimensions: 276 x 75 x 35mm.
M22G4MP
M21G1MP
M24G8MP
DE374
Blank PlatesDescription Cat. No. H (mm) W (mm)1 Gang blank plate M21BP 86 86
2 Gang blank plate M22BP 86 146
M21BP
Whi
te M
ould
ed A
cces
sorie
s
-
www.m2electrical.co.uk 55
M2
Pattress & Junction Boxes
Description Cat. No. H (mm) W (mm)1 Gang 19mm shallow pattress M2SP1 86 86
1 Gang 29mm deep pattress M2DP1 86 86
1 Gang 47mm deep pattress M2147P 86 86
Junction Boxes
In compliance with BS 7671: 2008Clamps 0.75mm² to 2.5mm² cable/flex
Flex & cable securely clampedExposed conductors avoidedEliminates strain on terminals
1 Gang Pattress Boxes
17th Edition Compliant Junction Box
Description Cat. No. H (mm) W (mm)2 Gang 29mm deep pattress M2DP2 86 146
2 Gang 47mm deep pattress M2247P 86 146
Dual accessory pattress M2DAP 86 172
2 Gang Pattress Boxes
Description Cat. No. H (mm) W (mm)1 Gang 19mm architrave pattress M21APB 86 32
2 Gang 19mm architrave pattress M22APB 172 32
Architrave Pattress Boxes
For M2 switches only.
Description Cat. No. H (mm) Dia (mm)5A 4 Terminal junction box M2JB54 22 62
20A 4 Terminal junction - large M2JB204L 30 80
20A 4 Terminal junction - small M2JB204S 27 60
20A 6 Terminal junction box M2JB206 30 86
30A 3 Terminal junction box M2JB303 36 90
Description Cat. No. H (mm) W (mm) W (mm)5 - 30A 4 Terminal 2 clamps M2JB5304 32 56 120
5 to 30 As Terminal capacityDurable urea construction
Easily accessible fixing holesFits downlighter aperture Ø58mm+
Reversible cable clamps for double cable entry
M2DP1
M2DP2
M21APB
M2JB54
M2JB5304
Typical down lighter applicationTypical Ring main application
Whi
te M
ould
ed A
cces
sorie
s
-
+44 (0) 1527 52067856
Whi
te M
ould
ed A
cces
sorie
sCeiling Accessories
10A Surface Pull Switches
Batten Lamp Holders
Pendant Sets
Ceiling Rose
Surface Pull Switches
Description Cat. No. H (mm) Dia (mm)10A Pull switch 1 way M26CS1 43 76
10A Pull switch 2 way M26CS2 43 76
Description Cat. No. H (mm) Dia (mm)Angle batten holder M2ABH - 85
Straight batten holder M2SBH - 72
Description Cat. No. H (mm) Dia (mm)6” Pendant set M26PS 33 86
9” Pendant set M29PS 33 86
Description Cat. No. H (mm) Dia (mm)Ceiling rose M2CRO1 33 86
Description Cat. No. H (mm) W (mm)45A Pull switch M245CS 86 86
50A Pull switch M250CS 86 86
M26CS2
M26PS
M2CR01
M2ABH
M250CS
-
www.m2electrical.co.uk 57
M2 - 3 pin and 4 pin commercial lighting connectors to
suit conduit boxes 50.8mm fixing centres. - Auxiliary pin version commonly used for emergency
lighting circuits.
- Other lengths and styles of flex e.g. Low Smoke Flex available.
Whi
te M
ould
ed A
cces
sorie
s
Lighting Connectors
Clip-In Ceiling PlugsDescription Cat. No.3 Pin plugs CCP
4 Pin plug CCPA
CCP
3 Pin Clip-In Ceiling RosesDescription Cat. No. L (m) Size (mm)3 Pin clip-in ceiling rose CCR - -
3 Pin clip-in ceiling rose CCR2-0.75 2 0.75
3 Pin clip-in ceiling rose CCR3-0.75 3 0.75
3 Pin clip-in ceiling rose CCR2-1.00 2 1.00
3 Pin clip-in ceiling rose CCR3-1.00 3 1.00CCR
4 Pin Clip-In Ceiling RosesDescription Cat. No. L (m) Size (mm)4 Pin clip-in ceiling rose CCR - -
4 Pin clip-in ceiling rose CCRA2-0.75 2 0.75
4 Pin clip-in ceiling rose CCRA3-0.75 3 0.75
4 Pin clip-in ceiling rose CCRA2-1.00 2 1.00
4 Pin clip-in ceiling rose CCRA3-1.00 3 1.00CCRA2-0.75
Lighting Trunking ConnectorsDescription Cat. No.3 Pin lighting trunking connector CCRT
4 Pin lighting trunking connector CCRTACCRT Trunking connector designed to suit standard 2” (50mm) lighting trunking.
-
+44 (0) 1527 52067858
Met
alcl
ad A
cces
sorie
sSwitches & Sockets
10AX Switches
16AX Key Operated Switch
16AX Large Rocker Switch
Description Cat. No. H (mm) W (mm) D (mm)1 Gang light switch 2 way M21LS2M 86 86 47
2 Gang light switch 2 way M22LS2M 86 86 47
3 Gang light switch 2 way M23LS2M 86 86 47
Triple pole switch M2TPS6M 86 86 47
Description Cat. No. H (mm) W (mm) D (mm)Key operated switch ‘EMG LTG’ M2DPKSM 86 86 47
Description Cat. No. H (mm) W (mm) D (mm)Wide rocker retractive switch ‘DOOR EXIT’ M2DESM 86 86 47
M22LS2M
20A Double Pole SwitchesDescription Cat. No. H (mm) W (mm) D (mm)20A Double pole switch M220DPSM 86 86 47
20A Double pole switch with neon M220DPSNM 86 86 47
20A Double pole switch c/w flex outlet M220DPS/FM 86 86 47
20A Double pole switch c/w neon & flex outlet
M220DPSN/FM 86 86 47
45A Double Pole SwitchesDescription Cat. No. H (mm) W (mm) D (mm)2 Gang 45A switch M2245SM 146 86 47
2 Gang 45A switch c/w neon M2245SNM 146 86 47
M2DESM
M220DPSN/FM
M2245SM
M2DPKSM
Description Cat. No. H (mm) W (mm) D (mm)1 Gang switched socket outlet M2113SSM 86 86 47
2 Gang switched socket outlet M2213SSM 86 146 47
2 Gang 2 USB switched socket outlet M2213SSUSBM 86 146 47
13A Sockets
M2213SSUSBM
-
www.m2electrical.co.uk 59
M2
Connection Units, Boxes & Plates
13A Connection Units
3A Connection Units
Description Cat. No. H (mm) W (mm) D (mm)Unswitched M213SUM 86 86 47
Unswitched c/w flex outlet M213SU/FM 86 86 47
Switched fused M213SSUM 86 86 47
Switched fused c/w neon M213SSUNM 86 86 47
Switched fused c/w flex outlet M213SSU/FM 86 86 47
Switched fused c/w neon & flex outlet M213SSUN/FM 86 86 47
Description Cat. No. H (mm) W (mm) D (mm)Key switched fused connection unit M23KSSUNM 86 86 47
Unswitched fused connection unit red M2RSUMFA 86 86 47
Key switched fused connection unit red RPE5142 86 86 47
M213SSUN/FM
1 Gang Back Boxes & Blanks
Modular Plates
Description Cat. No. H (mm) W (mm) D (mm)1 Gang back box M21GBOXM 86 86 47
1 Gang cover plate M21BPM 86 86 47
1 Gang back box* M21GBOXM/NKO 86 86 47
* - No knockouts.
2 Gang Back Boxes & BlanksDescription Cat. No. H (mm) W (mm) D (mm)2 Gang back box M22GBOXM 86 146 47
2 Gang cover plate M22BPM 86 146 8
2 Gang back box* M22GBOXM/NKO 86 146 47
* - No knockouts.
Description Cat. No. H (mm) W (mm) D (mm)1 Gang 1 module easyclip unit M21G1MPM 86 86 47
1 Gang 2 module easyclip unit M21G2MPM 86 86 47
2 Gang 4 module easyclip unit M22G4MPM 86 146 47
Met
alcl
ad A
cces
sorie
s
M22BPM
M21GBOXM
M21G2MPM
RPE5142
Fire Alarm Isolating SwitchesDescription Cat. No. H (mm) W (mm) D (mm)DP rotary key switch RPE5148 86 86 47
DP rotary key switch, neon fused RPE5147 86 146 47
RPE5147
-
+44 (0) 1527 52067860
Easy Seal SwitchesW
eath
erpr
oof A
cces
sorie
s
1 Gang Light SwitchDescription Cat. No. H (mm) W (mm)1 Gang light switch 2 way M2ES1LS2 90 90
M2ES1LS2
2 Gang Light SwitchDescription Cat. No. H (mm) W (mm)2 Gang light switch 2 way M2ES2LS2 90 90
M2ES2LS2
Retractive SwitchDescription Cat. No. H (mm) W (mm)2oA Retractive switch M2ES1RS 90 90
M2ES1RS
-
www.m2electrical.co.uk 61
M2
Easy Seal Enclosures
Wea
ther
proo
f Acc
esso
ries
Socket OutletsDescription Cat. No. H (mm) W (mm)13A 1 Gang switch socket outlet M2ES113SS 135 102
13A 1 Gang switch socket outlet (grey lid) M2ES113SSG 135 102
M2ES113SS
Socket OutletsDescription Cat. No. H (mm) W (mm)13A 2 Gang switch socket outlet M2ES213SS 135 162
13A 2 Gang switch socket outlet (grey lid) M2ES213SSG 135 162
M2ES213SS
RCD Socket OutletsDescription Cat. No. H (mm) W (mm)1 Gang RCD protected socket M2ES13SURCD 135 102
1 Gang RCD protected socket (grey lid) M2ES13SURCDG 135 102
M2ES13SURCDG
RCD Socket OutletsDescription Cat. No. H (mm) W (mm)1 Gang RCD protected socket M2ES2GRCD 135 162
1 Gang RCD protected socket (grey lid) M2ES2GRCDG 135 162
M2ES2GRCD
EnclosuresDescription Cat. No. H (mm) W (mm)1 Gang enclosure M2ES1ENC 135 102
1 Gang enclosure (grey lid) M2ES1ENCG 135 102
M2ES1ENC
EnclosuresDescription Cat. No. H (mm) W (mm)2 Gang enclosure M2ES2ENC 135 162
2 Gang enclosure (grey lid) M2ES2ENCG 135 162
M2ES2ENCG
-
+44 (0) 1527 52067862
Description Cat. No. H (mm) W (mm)1 Gang light switch 1 way GRA1LS1 86 86
Par
t M A
cces
sorie
sSwitches & SocketsIt is recommended that all Public Buildings are Part M compliant.A comprehensive range of Part M compliant wiring accessories for use in the public building sector that allows specifiers to maintain a consistent plate style
1 Way Dimmer Switch
1 Way 16AX Light Switch
GRA1LS1
Description Cat. No. H (mm) W (mm)1 Gang intermediate switch GRA1NTS 86 86
Intermediate 16AX Light Switch
Description Cat. No. H (mm) W (mm)1 Gang light switch 2 way GRA1LS2 86 86
2 Gang light switch 2 way GRA2LS2 86 86
3 Gang light switch 2 way GRA3LS2 86 146
4 Gang light switch 2 way GRA4LS2 86 146
2 Way 16AX Light Switches
Description Cat. No. H (mm) W (mm)1 Gang 400w dimmer 1 way GRA1400D/1 86 86
2 Way Dimmer SwitchesDescription Cat. No. H (mm) W (mm)1 Gang 250w dimmer 2 way GRA1250D 86 86
1 Gang 400w dimmer 2 way GRA1400D/2 86 86
2 Gang 250w dimmer 2 way GRA2250D 86 86
2 Gang 400w dimmer 2 way - double plate GRA2400D 86 146
2 Gang 400w dimmer 2 way - single plate GRA2400HD 86 86
3 Gang 250w dimmer 2 way GRA3250D 86 146
3 Gang 400w dimmer 2 way GRA3400D 86 146
4 Gang 250w dimmer 2 way GRA4250D 86 146
GRA1NTS
GRA2LS2
GRA1400D/1
GRA2400HD
throughout without compromise.Part M accessories are supplied in the M2 soft edge style, other colours in other ranges can be made available upon request.
GRA3250D
-
www.m2electrical.co.uk 63
M2
Description Cat. No. H (mm) W (mm)1 Gang 45A switch c/w neon GRA145SN 86 86
Description Cat. No. H (mm) W (mm)1 Gang 2 module plate GRA1G2MP 86 86
2 Gang 4 module plate GRA2G4MP 86 146
Description Cat. No. H (mm) W (mm)1 Gang blank plate GRA1BP 86 86
2 Gang blank plate GRA2BP 86 146
Switches & Sockets
Par
t M A
cces
sorie
s
13A SocketsDescription Cat. No. H (mm) W (mm)13A 1 Gang unswitched socket outlet GRA113S 86 86
13A 1 Gang switched socket outlet GRA113SS 86 86
13A 2 Gang unswitched socket outlet GRA213S 86 146
13A 2 Gang switched socket outlet GRA213SS 86 146
13A Connection Units
45A Double Pole Switch
Modular
Blank Plates
Coaxial, Data, Voice & Satellite Sockets
Description Cat. No. H (mm) W (mm)13A Unswitched connection unit GRA13SU 86 86
13A Switched connection unit GRA13SSU 86 86
13A Switched connection unit c/w neon GRA13SSUN 86 86
Description Cat. No. H (mm) W (mm)1 Gang TV GRA1TV 86 86
1 Gang telephone secondary GRA1TEF 86 86
1 Gang RJ45 data socket GRARJ45 86 86
1 Gang satellite connection plate GRA1SAT 86 86
1 Gang telephone master GRA1TMF 86 86
GRA113SS
GRA13SSUN
GRA145SN
GRA1TV
GRA1G2MP
GRA1BP
Compliance requirements: - ‘Accessories that contrast visually with their
surroundings’ - Individual switches on multiple socket outlets are
well ‘separated to avoid inadvertent selection’ &
indicate ‘ON’ status - Switches activated by ‘Large Switch Pads’ & ‘Simple
push button controls that require limited dexterity, for the visually impaired or infirm’.
-
+44 (0) 1527 52067864
Description Cat. No. H (mm) W (mm)Single medical isolated supply socket M2B113SIPS 86 86
Med
ical
Soc
kets
Medical Sockets
1 Gang Medical 13A Socket
Description Cat. No. H (mm) W (mm)Dual medical isolated supply socket M2B213SIPS 86 146
2 Gang Medical 13A Socket
M2B113SIPS
M2B213SIPS
- Surface mount box: 29mm - Flush mount box: 25mm - Large Twin Colour coded terminals aid loop wiring & complies to BS7671 - Clearly Engraved ‘MEDICAL EQUIPMENT ONLY’
Isolated Power Supply sockets for medical applications. In line with HTM06-01 and MEIGaN requirements with clean and dirty earth connections.Engraved in white lettering 'MEDICAL EQUIPMENT ONLY'Face plate manufactured from a blue urea compound which contains a very effective life-long anti-microbial & anti-fungal additive
Soft edge M2 styling & unbroken surface (screw cap covers) minimise dust & dirt traps improve effectiveness of infection control proceduresLarge twin terminals aid loop wiring & complies to BS7671 and BS1363 where applicable.
-
www.m2electrical.co.uk 65
M2
Tech
nica
l Inf
orm
atio
n
Technical Information
- BS1363 PT2: 1995 - CE Compliant: 93/68/EEC - EN61000-6-1:2007 - EN61000-6-3:2007/+A1:2011 - EMC Directive 2004/108/EC - EU REACH Regulation No 1907/2006
- Live & Neutral: 4 x 2.5mm2 - Earth: (dual) 8 x 2.5mm2
Single Pole
- 13A - 5V DC across 2 x USB outlets
50Hz
10 piece
Packaging Waste:Cardboard – 0.0013Kg / 125T/125T B FluteRoHS Complaint – ref: 2011/65/EUThe products manufactured & otherwise supplied by the company do not have any perceived or known hazardous materials or by-products that would be deemed hazardous to the environment.
Compliance:
Terminal Capacity:
Switching:
Current:
Voltage:Frequency:Environmental Issues:
Flush (1 gang): 35mm. Flush (2 gang): 25mmSurface: 29mm ref.M2DP2
Mounting Boxes:
UreaFace Plate Material:
The range of M2 socket outlets are designed for ease of installation and are available in one or two gang configurations, there are also double pole switching options available. - Red ‘ON’ indication to show
position of switch rocker. - Top access twin colour coded
angled terminals to help with ease of wiring.
- Neon switch rocker indication available.
- Captive terminal screws help with installation of sockets.
- Silver switching contacts with a 3mm contact gap.
Sockets
CONSUMERUNIT
2
NOTE: EARTH REMOVED FOR CLARITY FCU - FUSE CONNECTION UNIT
1 - UNSWITCHED SPUR2 - SPUR USING AN FCU NOT CONNECTED DIRECTLY TO RING3 - SPUR USING AN FCU CONNECTED DIRECTLY TO RING4 - FCU SUPPLYING FIXED EQUIPMENT5 - BS1363 SOCKET OUTLET
FIXEDEQUIPMENT
1
34
5
JUNCTIONBOX
JUNCTIONBOX
JUNCTIONBOX
DOMESTIC RING FINAL CIRCUITFOR FLOOR AREA UP TO 100m2
REFER TO IEE WIRING REGULATIONSFOR INSTALLATION PRACTICE
The range of M2 light switches are designed for ease of installation and are available in one or two gang, intermediate and multi-pole switch configurations, there is also double pole switching options available.
SwitchesCOMMON
1
LAMP
L
N
COMMON
12 2TWO WAY SWITCHES
Two way Switching
USB Sockets
-
+44 (0) 1527 52067866
Technical InformationTe
chni
cal I
nfor
mat
ion
The range of M2 dimmer switches are available in one and two gang configurations with up to four operational dimmers on one plate.
DimmersCOM
L1
LAMP
L
N
1
L2
2
DOTTED LINE SHOWS ALTERNATIVE SWITCH POSITIONS
TWO WAYDIMMER
COM
L2L1 COMMON
TWO WAYSWITCH
- One and two way switching available on each dimmer switch.
- Integrated over temperature protection fuse fitted (non replaceable).
- Leading edge phase control. - For use with inductive and resistive
loads. - Dimmer switches available in 250W,
400W & 1000W versions. - It is recommended that the lamps
Manufactured by LIF (Light Industry Federation) members only are used with the RPP range of dimmer switches.
COMMON
1
LAMP
L
N
COMMON
12 2
DOTTED LINE SHOWS ALTERNATIVE SWITCH POSITIONS
2
2 1
1TWO WAYSWITCH
TWO WAYSWITCH
INTERMEDIATESWITCH
Two Way Intermediate Switching Switches
Description Cat. No.Electronic Transformer (E) These can be mounted remotely, but are now mo