WinCC_V70_compatibility_list_e.pdf
Transcript of WinCC_V70_compatibility_list_e.pdf
s With what are SIMATIC WinCC V7.x, V 6.x and V5.x compatible? Entry-ID: 21927773
Changedate: 04.02.2013
This entry is from the Service&Pupport portal of Siemens AG,Sector Industry, Industry Automation and Drive Technologies.
The general terms of use (http://www.siemens.com/terms_of_use) apply.Page: 1/3
Client / Singlestation Server
Client / Singlestation Server
Client / Singlestation Server
Client / Singlestation Server
xx
x x
x x *16) x x *16) x x *16) x x *16) x x *16)
x *14, 15) x x *14, 15) x x *14, 15) x x *14, 15) xx *14, 15) x x *14, 15) x x *14, 15) x x *14, 15) x
x *15) x x *15) xx
x *2) xx x x xx
x *2) x
V2.05a *27) x *24) x x *24) x x *24) x x *24) xV3.00 *27) x *24) x x *24) x x *24) x x *24) x
OPC Historical Data Access (HDA) *26) V1.20 *27) x *24) x x *24) x x *24) x x
OPC Alarms and Events (A&E) *26) V1.10 *27) x *24) x x *24) x x *24) x x
OPC XML Data Access *26) V1.00 x *24) x x *24) x x *24) x x *24) x
Unified Architecture V1.01 x *24)
x
x
STEP 7 *13)
V5.4 SP3 x
V5.4 SP5
xx x
V5.1 SP1 Upd1 xV5.1 SP1
Windows Server 2008 R2 Hyper-V
VISTA *5)
Software
McAfee VirusScan Enterprise V8.8 Patch1
V7.0
x
WinCC Version
Automation License Manager
xx
V5.1 SP1 Upd2
x
xx
x
xxx
x
x *30)
x
x
x
x
x x
x x
xx
x
x
SIMATIC WinCC V7.0V7.0 SP3
x
x
V7.0 SP1 V7.0 SP2
xxx
x
x
xx
x
Virus Scanner
McAfee Application Control V5.1 Symantec AntiVirus Corporate Edition
V10.2 (Norton Antivirus)
Trend Micro OfficeScan V8.0 SP1 incl. Patch 2 *3)
Variablen Export/Import
WinCC Archive Configuration Tool
WinCC Communication Configurator
Variablensimulator
Microsoft Internet Explorer V7.0
V9.0Trend Micro OfficeScan V8.0 *3)
McAfee VirusScan Enterprise V8.7iMcAfee VirusScan Enterprise V8.8
Trend Micro OfficeScan V10.5 incl. Patch 1 (Build 1946) *3)
Trend Micro OfficeScan V10.5 incl. Patch 1 (Build 1799) *3)
Trend Micro OfficeScan V10.0 *3)
V5.1 SP1 Upd3
V6.0 SP2V6.0 SP1
V4.0 SP2
Microsoft Windows NetMeeting *9)
Trend Micro OfficeScan V10.6 *3)
V5.0 SP1
V3.0 SP1
McAfee VirusScan Enterprise V8.5
Symantec Endpoint Protection V11.0 (Norton Antivirus)
Dynamic Wizard EditorDocumentation Viewer
V5.4 SP3.1V5.4 SP4
V5.5
V5.5 SP2
WinCC CrossReferenceAssistant
WinCC Configuration Tool
Windows 7 *11)
Microsoft Windows(32-Bit)
Server 2003 R2 SP2 *4)
Server 2008 SP2 *4, 17, 19)
VISTA SP1 *5)
XP Professional SP2XP Professional SP3Server 2003 SP2 *4)
Windows 7 SP1 *11)
WinCC Smart Tools
Microsoft Windows(64-Bit)
Windows 7 SP1 *11)
Server 2008 R2 SP1 *4, 19)
Windows Server 2008 Hyper-VVMware ESXi 4.0
Virtualization
"RealVNC" Enterprise Edition V4.6.3 *18)
x
x
V8.0 x x
x
xx
x
x
x
OPC Data Access Spezification *25)
Remote Software"RealVNC" Enterprise Edition V4.6 *18)
Remote Desktop Connection (RDC) *10)
x
x
OPC
x
x
x
x
x x xx
xx *7)
x *7)
x
V5.5 SP1 x *28)
xx
x
s With what are SIMATIC WinCC V7.x, V 6.x and V5.x compatible? Entry-ID: 21927773
Changedate: 04.02.2013
This entry is from the Service&Pupport portal of Siemens AG,Sector Industry, Industry Automation and Drive Technologies.
The general terms of use (http://www.siemens.com/terms_of_use) apply.Page: 2/3
Client / Singlestation Server
Client / Singlestation Server
Client / Singlestation Server
Client / Singlestation ServerSoftware
V7.0WinCC Version SIMATIC WinCC V7.0
V7.0 SP3V7.0 SP1 V7.0 SP2
Edition 2007 HF1 (V7.0)Edition 2008 HF1 (V7.1)Edition 2008 SP2 (V7.1.2)Edition 2008 SP4 (V7.1.4)Edition 2008 SP5 (V7.1.5)
V8.0 (2010) (V8.0)V8.0 SP1V8.1 SP1
x
V7.0 SP3 Upd3 *29) x
V7.0 SP3 Upd2 *29)
x
V7.0 SP3 Upd3 *29) x
x
V7.0 SP2 Upd9 *29) x
V7.0 SP3 Upd1 *29)
x V7.0 SP2 Upd10 *29) x
x
V7.0 SP3
V7.0 SP3 Upd2 *29) x
x
V7.0 SP2 Upd10 *29)
V7.0 SP2 Upd6 *29) x
V7.0 SP2 Upd10 *29) x
V7.0 SP1 Upd4 x
V7.0 SP3
V7.0 SP2 Upd9 *29) x
V7.0 SP2 Upd9 *29) xV7.0 SP2 Upd10 *29)
WinCC/WebNavigator
WinCC/IndustrialX
WinCC/ODK
WinCC/ProAgent *2)
WinCC/ProcessMonitor
WinCC/Redundancy
WinCC/Server
WinCC/Central Archive Server (CAS)
WinCC Connectivity Pack / Station
WinCC/Change Control
WinCC/DataMonitor
WinCC/DowntimeMonitor
WinCC/Industrial DataBridge
x
V7.0 SP1
V7.0 SP2 Upd6 *29)V7.0 x x x
x
V7.0 SP3
x x
V7.0 SP3 Upd3 *29)
V7.0
V7.0 x x x
x
x
V7.0 SP2 x
V7.0 SP3 Upd2 *29)
V7.0 SP2 Upd6 *29)V7.0 x
V7.0 SP3 Upd1 *29)
V7.0 SP2 Upd9 *29)
V7.0 SP3
V7.0 SP3 Upd4 *29)
V7.0 SP3 Upd2 *29)
V7.0 SP3 Upd3 *29)
x
V7.0 SP2
V7.0 SP1
xx
x
x
x
x
x
x
V7.0
V7.0 SP3
V7.0 SP3V7.0 SP1
V7.0 SP3
V7.0 SP3 Upd4 *29)
V7.0 SP3 Upd1 *29)
V7.0 SP3 Upd4 *29)
V7.0 SP1
V7.0 SP3
V7.0 SP2 Upd6 *29)
V7.0V7.0 SP3
V7.0 SP2 Upd8 *29)
V6.0 SP4
V7.0 SP3
V7.0 SP1
V7.0
V7.0 SP2 Upd7 *29)
V7.0
V7.0 SP1
V7.0
V7.0 SP3 Upd4 *29)
xx
x
x
x
x
xx *31)
x
x
xx
x
x
x
x
x
x
x
x
x *31)
x
x
x
x
x
x
V7.0 x x x x
V7.0 SP3
xV7.0 x x x
V7.0 SP3 V7.0 xx
x
x
x
WinCC/User Archives
x x
x
SIMATIC NET *1, 8)
WinCC/Audit
x
V7.0 SP2 Upd8 *29)
x
x
x
V7.0 SP3 Upd1 *29)
V7.0 SP2 Upd7 *29)
x
x
x
x
x
V7.0 SP2 Upd8 *29)
V7.0 SP2 Upd8 *29) x
V7.0 SP2 Upd7 *29) x
x
V7.0 SP2 Upd7 *29) x
x
s With what are SIMATIC WinCC V7.x, V 6.x and V5.x compatible? Entry-ID: 21927773
Changedate: 04.02.2013
This entry is from the Service&Pupport portal of Siemens AG,Sector Industry, Industry Automation and Drive Technologies.
The general terms of use (http://www.siemens.com/terms_of_use) apply.Page: 3/3
Client / Singlestation Server
Client / Singlestation Server
Client / Singlestation Server
Client / Singlestation ServerSoftware
V7.0WinCC Version SIMATIC WinCC V7.0
V7.0 SP3V7.0 SP1 V7.0 SP2
*1)*2)*3)*4)*5)*6)*7)
*8)*9)
*10)*11)*12)*13)*14)*15)*16)
*17)
*18)*19)*20)*21)*22)*23)*24)*25)*26)*27)*28)*29)*30)*31)
x
V7.0 SP2 x *21)
V7.0 SP2 Upd6 *29) x
x
x
Installation of the congruent WinCC update is necessary for using this WinCC option.
V4.0 Upd1 x *20)
SIMATIC WinCC TELECONTROL
V7.0 SP2
Simatic Logon
Maintenance Station
2009 SP2
2009
Standard and Enterprise Edition
BATCH (for WinCC)
WinCC/Calendar Options
WinCC/Event Notifier
SIMATIC powerrate
SIMATIC B.Data
x
Notice Operating system, entry 9859007Only released for WinCC Singlestation.Only the "Corporate Edition" of Trend Micro OfficeScan virusscanner is released.
Installation of WinCC V7.0 SP2 Upd5 is necessary for using "RealVNC" Enterprise Edition V4.6.
Installation of WinCC V7.0 SP2 Upd5 is necessary for using SIMATIC powerrate V4.0 Upd1.
x *21)
V4.0 SP1
Ultimate / Business / Enterprise
V7.0 SP1 x
2007 SP3 x
x *23)
x
xV1.4 SP3 x
V5.2 SP1 x
xV1.5
V4.0
V7.1 SP1 x
Only for WinCC Server projects and max. 3 clients. See "WinCC Information System > Configurations > WinCC ServiceMode" and "WinCC Information System > Release Notes > Notes on Process Control Options > Server Project on Windows XP with Clients without their own project".
V7.0 SP3V3.0 SP1 x
V7.1 SP1 Upd1 *22) x
V7.0 SP2 Upd5 *29)
V7.0 SP2
V7.0 SP3
x
x *31)
x
x *31)
x *31)
x *31)
V1.4 *6) x x
V5.3
V7.0 SP3
x
x *31)
x
2007 SP4
x
x
2009 SP1x
You can access WinCC systems with a RDC via a console session.Professional, Enterprise and UltimateOnly for WinCC ClientsNotice operating system, entry 8250891
or higherIt is not absolutely necessary to have WinCC installed. In this case you cannot read/write data from/to WinCC. But it is a requirement to install MS Excel 2007 / XP /2003. MS Excel 2007 is released for WinCC V7.0, even if it is not mentioned in the WinCC Information System. WinCC is delivered with SIMATIC NET Softnet-S7 LeanMore information on installing and configuring "Microsoft Windows NetMeeting" is available on the Microsoft sites at http://support.microsoft.com/kb/154144/ and http://support.microsoft.com/kb/158623/
Clients without own project are not allowed for operating system Windows Server 2003 (R2).Windows Server is only released as a WinCC Client operating system if the WinCC Server operating system is not Windows XP.
Installation of WinCC V7.0 SP2 Upd4 is necessary for using WinCC/Calendar Scheduler V7.0 SP2 or WinCC/Event Notifier V7.0 SP2.Installation of WinCC V7.0 SP2 Upd5 or WinCC V7.0 SP1 HF4 is necessary for using BATCH (for WinCC) V7.0 SP1 Upd1.
Please consider the following link for a optionally downgrade of Windows Server 2008 R2: http://www.microsoft.com/windowsserver2008/en/us/downgrade-rights.aspxFind more informations concerning "RealVNC" for WinCC in entry-ID 55422236.The version "Windows Server 2008 Enterprise without Hyper-V" and "Windows Server 2008 Standard without Hyper-V" is not tested.
WinCC V7.0 SP2 Upd6 is necessary for using this WinCC option.Installation of WinCC OPC Server is only released on WinCC client with own project.
Installation of WinCC V7.0 SP2 Upd4 is necessary for using STEP 7 V5.5 SP1.
OPC DA is possible in WinCC Demo mode.OPC HDA, OPC A&E and OPC XML DA is not possible in WinCC Demo mode. You need a WinCC ConnectivityPack license.OPC DA, OPC A&E and OPC HDA is released for Connectivity Station. ConnectivityStation is not possible in WinCC Demo mode.
WinCC V7.0 SP3 Upd1 is necessary.
V5.2 x x