WIN2000 SMALL FLANGE + flowcurves

2
Options 1. Closing device 2. S cr een 3. Threaded connection, only for aluminium pipes. 4. Powder (epoxy) coating 5. Sounding pipe 6. Small flange connection (DN50-DN125) 7. Vacuum Breaker 8. Anti splash water type (Type 1B, DN50-DN125, recommended for fueltanks) Table 1: WIN2000 Air Pipe Head DN50-DN125 dimensions DN50 (2”) DN65 (2 ½”) DN80 (3”) DN100 (4”) DN125 (5”) A Ø108 Ø130 Ø160 Ø195 Ø235 B ±2.5 161 200 226 265 320 C Overflow 136 168 190 226 262 D Small flange connection: see Table 2 below Ball diameter Ø60 Ø75 Ø90 Ø105 Ø130 Weight kg. 2 2.75 3.75 6 8.5 Flow rate at 0,25 bar(m3/h)* 23 34 57 102 128 Flow rate at 0,25 bar(m3/h) ** 19 33 52 78 116 Max inlet air 11 95 10 8 95 The original The world’s largest producer of seawater resistant aluminium air pipe heads Innovative and high quality products WIN2000 Air pipe heads with small flange connection A      C     o     v     e     r       f       l     o     w      B

description

WIN2000 SMALL FLANGE + flowcurves_Winteb

Transcript of WIN2000 SMALL FLANGE + flowcurves

  • 5/24/2018 WIN2000 SMALL FLANGE + flowcurves

    1/2

    Options

    1. Closing device

    2. Screen

    3. Threaded connection, only for aluminium

    pipes.

    4. Powder (epoxy) coating

    5. Sounding pipe

    6. Small flange connection (DN50-DN125)

    7. Vacuum Breaker8. Anti splash water type (Type 1B,

    DN50-DN125, recommended for fuel tanks)

    Table 1: WIN2000 Air Pipe Head DN50-DN125 dimensions

    DN50

    (2)

    DN65

    (2 )

    DN80

    (3)

    DN100

    (4)

    DN125

    (5)

    A 108 130 160 195 235

    B 2.5 161 200 226 265 320

    C Overflow 136 168 190 226 262

    D Small flange connection: see Table 2 below

    Ball diameter 60 75 90 105 130

    Weight kg. 2 2.75 3.75 6 8.5

    Flow rate at 0,25

    bar(m3/h)*

    23 34 57 102 128

    Flow rate at 0,25

    bar(m3/h) **

    19 33 52 78 116

    Max inlet air 11 9 5 10 8 9 5

    The original

    The worlds largest producer of seawater resistant aluminium air pipe heads

    Innovative and high quality products

    WIN2000 Air pipe heads with small flange connection

    A

    Coverflow

    B

  • 5/24/2018 WIN2000 SMALL FLANGE + flowcurves

    2/2

    Max inlet air 11 9 5 10 8 9 5

    Pressure

    drop

    in

    kPa

    Pressure

    dro

    in

    kPa

    WIN2000 type 1 without screen size DN450

    Pressure

    dro

    in

    kPa

    Pressure

    drop

    ink

    Pa

    WIN2000 type 1 without screen sizes DN50-250

    WIN2000 type 1 with screen mesh18 sizes DN50-250 WIN2000

    type 1-B with screen mesh18 sizes DN50-125

    WIN2000 type 1 without screen sizes DN300-400

    WIN2000 type 1 with screen mesh18 sizes DN300-400

    WIN2000 type 1 with screen mesh30 sizes DN300-400

    WIN2000 Air Pipe Heads: Pressure drop vs. Flow rate Characteristics

    According to classification societies the air pipe head characteristic curves

    are to be taken into consideration at the design stage of the ballast system.

    Flowrate in m3/h

    The original