Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to...

25
Why Acoustic Sand Detectors don’t work?

Transcript of Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to...

Page 1: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Why Acoustic Sand Detectors

don’t work?

Page 2: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“The well is shut-in

yet we keep getting

indications of sand

production!”

Operator issues #1

Page 3: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“ We know we are

producing sand as

we keep filling up

our separator but

the sand detector

shows zero sand

production.”

Operator issues #2

Page 4: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“The CRO’s were

getting flooded

with so many sand

alarms we had no

choice but to turn

the system off”

Operator issues #3

Page 5: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“Why is it that for many operators

their acoustic monitoring systems

simply don’t work”

Why acoustic detectors don’t work

Page 6: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Detector fundamentals

• Passive microphone

transducer

• Detects noise of particles

impacting on pipe wall

• Also detects flow noise

and mechanical noise

Page 7: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

• Filter used to ensure

noise is predominantly

due to sand impacts.

Filter

• Not possible to

completely isolate sand

noise

Page 8: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Rate

• Quantify each wells sand

production

• Predict sand deposition in

vessels

• Estimate erosion

Page 9: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Calibration

Real time process data

• Flow rates: Oil, Gas, Water

• Velocity

• Pressure & Temperature

• Static Inputs

Page 10: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Background noise / Zero

• Flow well at different rates

Background noise curve

y = 3x3 - 40x

2 + 533x + 2000

0

2000

4000

6000

8000

10000

12000

0 2 4 6 8 10 12 14 16

velocity [m/s]

sig

nal [1

00n

V]

Velocity Signal [100nV]

0 m/s 2000

5 m/s 4 000

10 m/s 6 000

15 m/s 10 000

• Establish background

noise at each rate

• Determine background

noise curve / zero values

Page 11: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand noise / Step

• Flow well at different rates

• Inject known quantities of

sand at each rate

• Determine sand curve /

step values

Sand curve [1g/s]

y = 11x3 - 240x

2 + 3533x - 0

0

5000

10000

15000

20000

25000

30000

35000

40000

0 2 4 6 8 10 12 14 16

velocity [m/s]

sig

nal [1

00n

V]

Velocity Signal [100nV]

0 m/s 0

5 m/s 13 000

10 m/s 22 000

15 m/s 35 000

Page 12: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Rate

• Calculate sand rate

Production availability

Accurate particle sampling data

Raw data – Background noise

Sand Noise Sand rate =

Page 13: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

y = 3x3 - 40x2 + 533x + 2000

0

2000

4000

6000

8000

10000

12000

0 2 4 6 8 10 12 14 16

y = 11x3 - 240x2 + 3533x - 0

0

5000

10000

15000

20000

25000

30000

35000

40000

0 2 4 6 8 10 12 14 16

Background noise curve

Sand curve for 1g/s

Velocity = 11 m/s Reading = 21 040 [100nV]

Background noise = 3*113- 40*112 + 533*11 + 2000

= 7016 [100nV]

Sand noise [1g/s] = -11*113- 240*112 + 3533*8 + 0

= 24463 [100nV]

Sandrate = Reading - Background noise

Sand noise

= 21040 - 7016

24463

= 0.57 g/s

Sand Rate – worked example

Page 14: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Re-calibration

• Every 6 – 12 months

Stable process flow

POB capacity

• Change in the well flowing

conditions

Page 15: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Quantification criteria

Stable process flow

Real time process data

Accurate particle sampling data

POB capacity

Production availability

Page 16: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Raw signal interpretation

You are the

experts on your

sand production!

Page 17: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Data Interpretation

Acoustic Data – Sand Event?

Page 18: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Acoustic data & erosion probe data– Sand Event - Yes

Data Interpretation

Page 19: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Acoustic data, erosion probe data, pressure & temperature– Sand Event - Yes

Data Interpretation

Page 20: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Raw Signal

• Determine sand

producing wells

• Understand how process

operations affect sand

production

• Estimate erosion – if

used in conjunction with

sampling data.

Page 21: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Case Study

Surfactant treatment and Pressure reduction

Page 22: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Case Study (cont.)

Surfactant treatment

Platform Trip during pressure reduction

Well cycled

Page 23: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Case Study (cont.)

1. Well flowing normally

2. Well cycled closed for 9 hours

3. Noise signal consistent with sand production 4. Well begins to ‘clean-up’

Page 24: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

SGA – Case Study (cont.)

Outcome: Surfactant treatment successful

Staged pressure reduction successful

! Sand production following well start-ups

! Requirement for ‘hard’ bean-up

Page 25: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Monitoring Services

http://www.sand-monitoring.co.uk

Questions?