WHERE SAFETY MEETS EFFICIENCY - Ultradent while preserving more tooth structure. ... WHERE SAFETY...

7
WHERE SAFETY MEETS EFFICIENCY

Transcript of WHERE SAFETY MEETS EFFICIENCY - Ultradent while preserving more tooth structure. ... WHERE SAFETY...

WHERE SAFETY MEETS EFFICIENCY

• Get the safety of reciprocation (90/̊30˚) and the efficiency of rotary (360˚)

• After preflaring and creating the glide path, complete any procedure with just two files

• Choose between multiple finishing options for final enlargement

• Use for both treatment and retreatment

CLINICIANS NEED A FILE SYSTEM THAT IS COMPATIBLE WITH BOTH RECIPROCATION AND ROTARY

DON’T LET YOUR CHOICE LIMIT YOU

ROTATIONAL MOVEMENT AROUND A SINGLE AXIS

ROTATIONAL MOVEMENT THAT ALTERNATES BETWEEN CLOCKWISE AND

COUNTER-CLOCKWISE DIRECTIONS

ROTARYRECIPROCATION

SAFETY

OR

EFFICIENCY

Clinicians have always had to choose between reciprocation and rotary; safety and efficiency.

So which do you choose?

Mini Handle (11 mm) ISO Identification Colors

.04 TaperThermal Treated NiTi Alloy

S Cross Section Progressive Pitch Enhanced Flutes Non-Cutting TipImproves control and visualization of the file Allows for easy

identification

Reduces the risk of separation, excessive removal of dentin, and dentin cracks

Improves resistance and flexibility

Double cutting edges with right positive action for asymmetric reciprocation and rotary action

Prevents “screw in” effect Larger space between flutes maximizes debris removal

Prevents ledging and keeps the file in the canal

OVERVIEWEach Genius file is designed with a constant .04 taper to shape and clean the root canal system while preserving more tooth structure. They are compatible with both reciprocation and rotary movement. Genius files operate ideally in the 90º clockwise and 30º counter clockwise reciprocation movement provided by the Genius® motor.

WHERE SAFETY MEETS EFFICIENCY

This reciprocation movement not only reduces the risk of file fracture due to torsional and cyclic fatigue, but also creates a smooth path to the apical limit. After safely reaching the apical limit, Genius files can then be used in 360° rotation to better remove debris from the canal.

NOW YOU CAN EASILY MATCH THE GENIUS FILES TO THE GENIUS MOTOR WITH THE TOUCH OF A BUTTON

Safely creates access to the working length and minimizes file cyclic and torsional fatigue. Enables the use of a brushing movement to

clean and shape oval canals.

(90 /̊30˚)

Refines canal walls while shaping and removing debris after reciprocation.

(360 )̊

RECIPROCATION SETTING ROTATION SETTING

ROTATING - P1Ratio: 8:1 FWDRpm: 300 A/R: SARTorque: 0.5Ncm

RECIPROCATING - GENRatio: 8:1 FWD: 90Rpm: 350 REV: 30

30 .08 3743A18 mm

25 .04 3746A21 mm

3747A25 mm

30 .04 JJ 3748A21 mm

3749A25 mm

35 .04 J 3750A21 mm

3751A25 mm

40 .04 I 3754A21 mm

3755A25 mm

50 .04 I 3756A21 mm

3757A25 mm

PROCESS

FINISHING FILE SELECTION

3752A Genius File Starter Kit (21 mm)3753A Genius File Starter Kit (25 mm) 1 x 30 .08 Orifice Shaper 1 x 25 .04 Genius File 1 x 30 .04 Genius File 1 x 35 .04 Genius File 1 x 40 .04 Genius File 1 x 50 .04 Genius File

3744A Genius File Intro J Kit (21 mm)3745A Genius File Intro J Kit (25 mm) 1 x 30 .08 Orifice Shaper 1 x 25 .04 Genius File 1 x 35 .04 Genius File

Genius File - Refill 6 Packs

Genius File Orifice Shaper - Refill 3 Packs

GENIUS FILES AND ACCESSORIES

Curvature

W.L.

W.L.

Foramen

Foramen

ROTATING - P1Ratio: 8:1 FWDRpm: 300 A/R: SARTorque: 0.5Ncm

RECIPROCATING - GENRatio: 8:1 FWD: 90Rpm: 350 REV: 30

SHAPING APICAL FINISHING

PREFLARING WORKING LENGTH DETERMINATION

OR

IJJJ

JJ

Orifice Shaper

J I I

CURVED AND NARROW CANALS

CURVED CANALS

STRAIGHT CANALS

2 3

1

OR OR OR

25 .04 30 .04

30 .08

35 .04 40 .04 50 .04

ROTATING - P1Ratio: 8:1 FWDRpm: 300 A/R: SARTorque: 0.5Ncm

RECIPROCATING - GENRatio: 8:1 FWD: 90Rpm: 350 REV: 30

Endo-Eze Genius Gutta Percha

60 x Genius Gutta Percha 0.04 Taper Points

4299 Assorted, 25,30,35,40,50 (12 each)4294 Size 254295 Size 304296 Size 354297 Size 404298 Size 50

F29030 Endo-Eze Genius Motor

1 x Genius motor 1 x Handpiece 1 x Foot pedal 1 x Power cord

4056 Endo-Eze Genius 8:1 Contra-Angle

1 x Contra-Angle

Ultradent has always been committed to

advancing technology and science. We have

several different sectors in Research and

Development dedicated exclusively to the

development of new materials and techniques

for better global dentistry. The Endodontics

Research and Development sector has made

especially large investments in state-of-the-art

equipment and engineering.

Our new Endo-Eze brand combines these

efforts with the best technology in order

to simplify endodontics while maintaining

efficiency and safety.

EVERYTHING YOU NEED FROM BEGINNING TO ENDO

Foramen indentification

Tips, syringes, and chemicals

Engine-driven glide path

Interappointment intracanal medication

Post and core reconstruction

Hand files Ultrasonification ObturationReciprocation and rotary instrumentation

Coronal restoration

Improving Oral Health Globally1003834.4 091616

U L T R A D E N T . C O M800.552.5512© 2016 Ultradent Products, Inc. All Rights Reserved.