WHAT’S IN THE BOX? - Tandberg Data · RDX® QuikStor™ Internal USB and Internal SATA WHAT’S...

3
RDX® QuikStor™ Internal USB and Internal SATA WHAT’S IN THE BOX? USB 3.0 DC Input Voltage and Rated Input Current 5VDC/0.9A and 12VDC/0.003A SATA DC Input Voltage and Rated Input Current 5 VDC/1.5A Power Ratings Thank you for selecting Tandberg Data AccuGuard data protection software. Key Benefits: Powerful Data Deduplication • Quick Point-in-Time Recovery • Fast File-Level Searching • Microsoft Exchange Protection • Microsoft SQLProtection • Simple User Interface Tandberg Data AccuGuard™ License Activation 433985 Rev C Visit www.tandbergdata.com/login Account Sign In Sign in or create an account Enter the Promo Code RDX10 LicenseAgreement Click to agree Enter the Authorization Code LAC# ## ## ## Download AccuGuard Software Click the download link on the bottom License Key Receive your key via email 1 2 3 4 5 6 7 1 2 3 4 5 USB or SATA Cable Power Adapter Cable Note: A power adapter cable only ships with the RDX internal SATA drive and the RDX internal USB 3.0 drive. Mounting Screws AccuGuard License Activation Card Note: AccuGuard software is only included with selected RDX products Warranty Card 1. 2. 4. 5. 3. Visit the Support section of the Tandberg Data web site (www.tandbergdata.com) for more information, including product warranty and registration, knowledge base articles, user documentation, and technical support. For More Information for USB 3.0 for USB 2.0 for SATA for SATA The following power ratings represent typical-use performance. for USB 3.0 8 9 Activate Software Click the appropriate link on the right Update RDX Utility and Firmware Click the download link on the bottom

Transcript of WHAT’S IN THE BOX? - Tandberg Data · RDX® QuikStor™ Internal USB and Internal SATA WHAT’S...

Page 1: WHAT’S IN THE BOX? - Tandberg Data · RDX® QuikStor™ Internal USB and Internal SATA WHAT’S IN THE BOX? USB 3.0 DC Input Voltage and Rated Input Current 5VDC/0.9A and 12VDC/0.003A

RDX® QuikStor™ Internal USB and Internal SATA

WHAT’S IN THE BOX?

USB 3.0 DC Input Voltage and Rated Input Current 5VDC/0.9A and 12VDC/0.003A

SATA DC Input Voltage and Rated Input Current 5 VDC/1.5A

Power Ratings

Thank you for selecting Tandberg Data AccuGuard data protection software.

Key Benefits: • Powerful Data Deduplication • Quick Point-in-Time Recovery • Fast File-Level Searching • Microsoft Exchange Protection • Microsoft SQL Protection • Simple User Interface

Tandberg Data AccuGuard™ License Activation

433985 Rev C

Tandberg BluePantone PMS 287CMYK 100-068-000-012

Tandberg OrangePantone PMS 151CMYK 000-043-087-000

Fonts: Arial Black, Arial Regular

Visitwww.tandbergdata.com/loginAccount Sign InSign in or create an account

Enter the Promo CodeRDX10

License AgreementClick to agree

Enter the Authorization CodeLA C# ## ## ##

Download AccuGuard SoftwareClick the download link on the bottom

License KeyReceive your key via email

1

2

3

4

5

6

7

1

2

3

4 5

USB or SATA Cable Power Adapter Cable

Note: A power adapter cable only ships with the RDX internal SATA drive and the RDX internal USB 3.0drive.

Mounting Screws

AccuGuard License Activation CardNote: AccuGuard software is only included with selected RDX products

Warranty Card

1.

2.

4.

5.

3.

Visit the Support section of the Tandberg Data web site (www.tandbergdata.com) for more information, including product warranty and registration, knowledge base articles, user documentation, and technical support.

For More Information

for USB 3.0 for USB 2.0

for SATA

for SATA

The following power ratings represent typical-use performance.

for USB 3.0

8

9

Activate SoftwareClick the appropriate link on the right

Update RDX Utility and FirmwareClick the download link on the bottom

Page 2: WHAT’S IN THE BOX? - Tandberg Data · RDX® QuikStor™ Internal USB and Internal SATA WHAT’S IN THE BOX? USB 3.0 DC Input Voltage and Rated Input Current 5VDC/0.9A and 12VDC/0.003A

1

2

3 4

START HERE — Page Two

Mount the RDX QuikStor

Install RDX Utility Connect Data and Power Cables Load RDX Cartridge

• Power off the computer and open the server cover.• Slide the RDX QuikStor into the drive opening. • Secure the dock with the four supplied mounting screws.

Note: The RDX Utility installs only on Windows.

ServerFront

RDX QuikStor

Write Protect

Keyed Corner

• Connect the data cable and the power cable to the back of the RDX QuikStor. The dock connections are keyed to ensure the correct

• For SATA interfaces, connect the SATA cable to your system’s SATA controller (built-in or PCI card).

• For USB 3.0 interfaces, connect the USB 3.0 cable to the PC motherboard or a USB host bus adapter.

• For USB 2.0 interfaces, connect the USB 2.0 cable to the PC motherboard or the USB host bus adapter. Align pin 1 on the cable connector with the pin 1 location on the motherboard. The pin 1 location on the cable connector is marked with a triangle .

Warning: Connecting the USB 2.0 Cable incorrectly to the PC will result in damage. Verify pin layout on the motherboard versus the cable connector pin-out (see diagram). Consult your motherboard manual for the pin 1 location on the mating USB connector.

• Replace the server cover and turn the computer on.

+5VDCDATA -DATA +GNDKey

PIN SIGNAL PIN SIGNAL 1 VCC 2 VCC 3 USB0- 4 USB 1- 5 USB0+ 6 USB 1+ 7 GND 8 GND 9 Key 10 USBOC

1 2

9 10

USB 2.0 cable connector pin-out

USB SATA

• Go to www.Tandbergdata.com..• Chose „Support“ from the main menu.

• Click on „Drivers and Downloads“ at theright hand side of the page.

• Click the „Go“-Button near RDX QuikStor.• Choose „RDX_Utility.zip“.• Click on „Download RDX Utility“.• Register and download the RDX Utility.• Unpack the zip-file, start „setup.exe“ and

follow the installation instructions.• Download and install the lastest Firmware.

Page 3: WHAT’S IN THE BOX? - Tandberg Data · RDX® QuikStor™ Internal USB and Internal SATA WHAT’S IN THE BOX? USB 3.0 DC Input Voltage and Rated Input Current 5VDC/0.9A and 12VDC/0.003A

5

Page Three

RDX QuikStor FeaturesInstall AccuGuard Server for RDX

Tandberg Data AccuGuard backup and recovery software is only included with select RDX products. If your product includes an AccuGuard licence activation card, follow the instructions on the card to download and install the software.

Note: AccuGuard installs only on Windows operating systems.

• Follow the steps on your AccuGuard License Activation card to download the software.

• Run the AccuGuard Server for RDX.exe

• At the screen of the setup wizard, be sure the checkbox “Run AccuGuard Server for RDX now” is selected. Click [Finish].

• Click “Add a License Key.” Enter the license key that you received via email in the above download process.

• Click [Yes] to activate the software license, then click [OK]. The AccuGuard Home screen opens.

Create a Data Protection Plan6

• From the Home screen, select “Add a Protection Plan” in the upper-right area of the screen.

The Create a Protection Plan inter-face opens.

• Complete the tasks in order, begin-ning with the Start tab and ending with the Schedule tab.

LED Status Meaning DescriptionOn Green Ready Cartridge is ready.

Blinking Green

Activity Reading, writing, seeking.

On Amber Fault Unit has detected a cartridge fault condition. For more information, run a diagnostic application.

Eject Button/Power LEDThe following table describes the Power LED’s function:

LED Status Meaning DescriptionOff No Power Unit does not have power.

On Green Ready Power is On and the unit is working properly.

Blinking Green

Ejecting Unit is rejecting the cartridge.

On Amber Fault Unit has detected a fault condition. For more information, run a diagnostic application.

Blinking Amber

Prevent Host computer is accessing the media and the user has pressed the Eject Button. The unit will eject the cartridge after the Host access completes.

The following table describes the Activity LED’s function:Activity LED

© 2013 Tandberg Data. All rights reserved. RDX QuikStor and AccuGuard are trademarks of Tandberg Data. RDX is a registered trademark of Tandberg Data S.a.r.l. All other trademarks are the property of their respective owners.

Eject Button/Power LEDActivity LED

Refer to the following Protection Plan Tab Tasks section for more information.

Emergency Eject HoleTab What to Do

Start Select one of the following protection plan options:

• Personal Data and Settings — backs up data that is located in the Documents and Settings folder, such as email account and desktop settings.

• Custom — backs up the and folders that you manually select.

• Everything — backs up all disk drives on the host computer (recommended).

• Exchange Storage Groups — backs up Microsoft Exchange Storage Groups on the host computer. (This option only applies if MS Exchange is installed on the host.)

• SQL Server Databases — backs up SQL Server databases on the host computer. (This option only applies if SQL Server is installed on the host.)

Selections The Selections tab function varies depending on which plan option you initially selected.

• Personal Data and Settings-— select the user ac-count settings to include in your protection plan.

• Custom — select the drives, directories, and to include in your protection plan.

• Everything — the software automatically selects all disk drives on the computer for backup.

• Exchange Storage Groups -— select one or more the storage groups to include in your protection plan.

• SQL Server Databases — select one or more data-bases to include in your protection plan.

Plan Name Type a name and description for the backup plan.

Cartridges Select one or more storage locations for the protection plan. If necessary, click [Add] to include a storage loca-tion. You can add storage located on a local, network, or removable disk.

Schedule Choose a time and frequency for your protection plan.

(The Advanced option allows you to schedule a backup run time under certain circumstances, such as when the system is idle.)

Protection Plan Tab Tasks

P/N 433822 Rev. F