What is the AnyRidge way? · • Esthetic design & varied abutment selection • Super...
Transcript of What is the AnyRidge way? · • Esthetic design & varied abutment selection • Super...
Characteristics & AdvantagesI. Design ConceptII. Surgery III. Prosthetics IV. Maintenance
Fixture Product & PackageI. Dimension II. Size III. Package
Cover Screw & Healing Abutment
Abutment & Prosthetic optionsI. Fixture level Prosthesis II. Abutment level Prosthesis 1. Solid Abutment & Components 2. Multi-unit Abutment & ComponentsIII. Overdenture Prosthesis 1. Meg-Rhein Abutment & Components
AnyRidge® Surgical KitI. Surgical KitII. Prosthetics KitIII. BonEx KitIV. Bone Profiler KitV. Optional components
Extra Option ProductsI. i-GenII. MEGA ISQIII. MEG-TORQIV. 911 Kit
Clinical cases www.ausmegagen.com.au
Have you made the PARADIGM SHIFT yet?Do it the AnyRidge way!
What is the AnyRidge way?
For clinicians…less invasive, fast,
simple, predictable, & esthetically
superior implant treatment
Realising theONE-DAY ImplantTM
For patients…strong new esthetic &
functional teeth via painless & rapid
treatment
AnyRidge does it right!AnyRidge goes FAR BEYOND standard expectations of dental implants…
The key benefits of AnyRidge implants become evident when considering immediate loading…
With the new loading protocol developed based on clinical results with AnyRidge, your patients have new smiles faster than ever….
• Guaranteed excellent stability, even with compromised bone density• Less reduction & more preservation of cortical bone• Wider implant possibilities than crestal width• Clinically proven safety • Faster & stronger osseointegration• Esthetic design & varied abutment selection• Super implant-prosthetic connection• Innovative R2GATE software for completing implant & prosthesis in ONE DAY
AnyRidge – a new design standard on the global stageLaunched in 2009 as a biologically-inspired implant concept, AnyRidge consistently surpasses clinical benchmarks
– 055054 AnyRidge®
Small but Strong Abutment ScrewDiameter 1.8mm
Thicker abutment wallMore favorable for path adjustment
Optimum post taper✔ Different taper according to post diameter (8°, 10°, 12°, 14°)✔ Wider diameter has more taper!
Various cuff height2.0, 3.0, 4.0, 5.0mm
Single connectionAbutment can be used on any size of fixture
Wider fixture in a narrow crestMaximizes long-term survival of a fixture
No cutting edge, but strong self-threading✔ Sharp cutting flutes slice and widen bone gradually.✔ No wobbling on cortical slope in anterior immediate placement case.
Various post height4.0, 5.5, 7.0, 9.0mm
Flexibility of 1mm1mm trimmable margin gives restorative
flexibility without changing B-L dimension
Biologic S-lineBiologic S-line provides
seamless natural-lookingemergence profile
Maximum preservation of cortical bone
Important for esthetics and long-term prognosis
Narrow diameterWider fixture into a small osteotomy socket (less invasive surgery) is important to pre-serve marginal hard and soft tissues.
Taper designEasy to place always guarantees
excellent initial stability
Knife-ThreadsOffer progressive bone condensing, ridge expansion, maximized compressive force
resistance, and minimized shear force production.
Characteristics & Advantages » Ⅰ. Design Concept
I. Design ConceptCharacteristics & Advantages
– 057056 AnyRidge®
➲
➲
➲
➲ ➲ ➲
Lance Drill
Stopper Drill 2.8
AnyRidge® Fixture 5.0
Lance Drill
Stopper Drill 2.8
Stopper Drill 3.3
Marking Drill 3.8
AnyRidge® Fixture 4.0
II. Surgery
• AnyRidge® system has no fixed drilling protocol, just make your own protocol based on patient’s bone quality to attain preferred initial stability or simply drill an osteotomy socket to given conditions and then decide the diameter of a fixture.
Example 1) Ø5.0mm fixture can be placed 2.9mm osteotomy socket in D4 bone. Excellent initial stabil-ity can be attained
Example 2) In hard one, it is highly recommended to make a socket almost same diameter size as a fixture
• Improved drill design has simplified drilling sequence, you can even harvest autogenous bone using these specially designed drills. (Recommended speed : 50 RPM, 50 Ncm with saline solution irrigation)
• The best way to get ideal initial stability with AnyRidge system is placing a fixture using a surgical engine, leaving one or two treads above the crest; then use ratchet wrench to place the platform at the desired position.
• Soft bone The super self-tapping threads have a single core diameter that facilitates minimal site preparation by utilizing a smaller osteotomy to place a wider fixture with special threads.
• Hard bone AnyRidge® Fixture with its super self-tapping thread design is easier than other traditional implants at hard bone. *Caution! : The osteotomy socket (drilling) size should almost reach the size of fixture to avoid getting stuck in the bone during placement.
1. Fixture placement
Easy way to avoid stuck in the bone during AnyRidge implant placement1. Due to extremely strong initial stability of AnyRidge fixture, it can be stuck in the middle during placement especially in mandibular hard bone. Please consider ‘One millimeter Rule’ to avoid this in the best and easiest way. Clinician can customize the drilling sequence once he fully understand the concept and characteristics of AnyRidge system to get preferred initial stability. ‘One millimeter Rule’ is simple; if an implant engine (40Ncm) stops leaving one millimeter above the crest, use ratchet wrench to screw it down to preferred position. We recommended to place implant platform 0.5~1.0mm under the crest.
2. If a fixture stucks in the middle leaving more than 1mm above the crest in hard mandibular bone, it is recommended to remove it using a wrench rather than trying to screw it down with excessive torque. Please use a cortical bone drill that is included in a surgical kit, the depth of cortical bone drilling can be adjusted according to the bone condition. Then, place the same fixture into the osteotomy socket.
<1mm >1mm1mm 1mm
1 2
2. Customized drilling Sequence
Excellent initial stability, even at compromised bone density. AnyRidge® Fixture cuts bone smoothly and condenses it simultaneously.
Characteristics & Advantages » Ⅱ. SurgeryCharacteristics & Advantages » II. SurgeryCharacteristics & Advantages » I. Design Concept
Characteristics & Advantages » III. ProstheticsCharacteristics & Advantages » III. Prosthetics
– 057056 AnyRidge®
Separation force between fixture and abutment after cold welding.
(n=5)
25.36
49.49
Company A1.5° Connection
AnyRidge5° Connection
Company B 8° Connection
11.46
A
B
AnyRidge
Ⅲ. Prosthetics
• Magic Five (5° Internal connection) Now you can be free from screw loosening with our unique connection (5 degree morse taper) which gives perfect hermetic sealing. Biologic width is minimized due to no micro gap, and crestal bone health is well maintained.
Helps to achieve beautiful, natural-looking esthetics.
Feel AnyRidge connection. It starts with impression taking and lasts until final restoration.
Every case, every shape, every size. Everything was considered to satisfy every need.
Better esthetic outcomes from wide variety of prosthetic options!Stop worrying about screw loosening!
Performed Retention Test to evaluate the fixture-abutment retention force using Universal Testing Machine-R&D center in MegaGen Implant Co.,Ltd.(2009)-
1. No screw loosening, less biologic width!
2. Biologic S-line
3. Optimum hex height
4. All indications, various abutment options
Characteristics & Advantages » Ⅲ. Prosthetics
VariousPost Heights
Complete Hermetic Seal Cuff Height
S-line
[SEM Image] Magic Five Connection : 5° Morse Taper
– 059058 AnyRidge®
Characteristics & Advantages » Ⅲ. Prosthetics
1. All transitional and temporary components have ‘Ledges’ on the bottom
2. All permanent abutments will make strong connections with fixtures, even with finger force!
• Cover Screws, Healing Abutments, Impression Coping (transfer and pick-up type), Temporary Cylinders have ledges on the bottom which prevent from cold welding with a fixture.• Hand Drivers(1.2 Hex) or Impression Drivers can be used easily to screw these components in and out.
• 25~35Ncm is recommended to connect a permanent abutment into a fixture.
• A fixed abutment cannot be removed with finger force even after complete removal of Abutment Screw because of perfect cold welding. To remove a permanent abutment, Abutment Removal Driver should be used.
▸▸ Two different connections between a fixture & a component
Characteristics & Advantages » IV. Maintenance Characteristics & Advantages » III. Prosthetics
– 059058 AnyRidge®
Due to extremely strong connection force, you don’t have to worry about screw loosening. Please use our special ‘removal driver’ when you want to remove an abutment from a fixture.
Characteristics & Advantages » Ⅲ. Prosthetics
Hand Driver (1.2 Hex)(Refer to Page.349)
Abutment Removal Driver
(Refer to Page.350)
1
4 5 6
2 3
1. Use a Hand Driver(1.2 Hex) to unscrew Abutment Screw.2. Continue to turn counter-clockwisely until you feel a click of disengagement.3. Push down Hand Driver once again to catch and fix Abutment Screw.4. Lift up Hand Driver lightly and continue to turn counter-clockwisely until Abutment Screw engages with the inner screw of Abutment.5. Remove Abutment Screw completely from the abutment6. Insert an ‘Abutment Removal Driver’ and continue to turn clockwise until the abutment comes out of fixture. You can feel some resistance during screw-down of the Abutment
Removal Driver, but don’t worry, simple exert is needed disconnect the abutment from the fixture.
▸▸ How to remove Permanent Abutment from Fixture?
– 061060 AnyRidge®
300.0
250.0
200.0
150.0
100.0
50.0
0.03.5
AnyRidge
4.0 6.0 (n=8)
Diameter
kgf
0
5
-5
15
25
35
45
2 4 6
Stre
ss(M
Pa)
Length (mm)
AnyRidge 4.5 x 10mm
AnyRidge 5.5 x 10mm
Company OS
Company NB
- Less insertion torque- Excellent initial stabilization- Resistance to compressive force- Minimal Shear force creation- Higher BIC
- Round faced and narrow thread design
Stress Distribution (Fixture-Bone)Cortical Bone Thickness - 0.8mmCancellous bone level - D4
EZ Plus Rescue
300.0
250.0
200.0
150.0
100.0
50.0
0.03.5
AnyRidge
4.0 6.0 (n=8)
Diameter
kgf
0
5
-5
15
25
35
45
2 4 6
Stre
ss(M
Pa)
Length (mm)
AnyRidge 4.5 x 10mm
AnyRidge 5.5 x 10mm
Company OS
Company NB
- Less insertion torque- Excellent initial stabilization- Resistance to compressive force- Minimal Shear force creation- Higher BIC
- Round faced and narrow thread design
Stress Distribution (Fixture-Bone)Cortical Bone Thickness - 0.8mmCancellous bone level - D4
EZ Plus Rescue
300.0
250.0
200.0
150.0
100.0
50.0
0.03.5
AnyRidge
4.0 6.0 (n=8)
Diameter
kgf
0
5
-5
15
25
35
45
2 4 6
Stre
ss(M
Pa)
Length (mm)
AnyRidge 4.5 x 10mm
AnyRidge 5.5 x 10mm
Company OS
Company NB
- Less insertion torque- Excellent initial stabilization- Resistance to compressive force- Minimal Shear force creation- Higher BIC
- Round faced and narrow thread design
Stress Distribution (Fixture-Bone)Cortical Bone Thickness - 0.8mmCancellous bone level - D4
EZ Plus Rescue
300.0
250.0
200.0
150.0
100.0
50.0
0.03.5
AnyRidge
4.0 6.0 (n=8)
Diameter
kgf
0
5
-5
15
25
35
45
2 4 6
Stre
ss(M
Pa)
Length (mm)
AnyRidge 4.5 x 10mm
AnyRidge 5.5 x 10mm
Company OS
Company NB
- Less insertion torque- Excellent initial stabilization- Resistance to compressive force- Minimal Shear force creation- Higher BIC
- Round faced and narrow thread design
Stress Distribution (Fixture-Bone)Cortical Bone Thickness - 0.8mmCancellous bone level - D4
EZ Plus Rescue
Ⅳ. MaintenanceUnique and sturdy design provides long-term stability!
1. Higher cortical bone preservation is guaranteed
AnyRidge does not depend on cortical bone for initial stability; decreased stress on corti-cal bone helps to prevent bone resorption after implantation.
• More cortical bone = More soft tissue volume = Beautiful gingival line Advanced coronal design allows maximum cortical bone preservation around implants. Beyond osseointegration, AnyRidge can assure beautiful gingival line by preserving and maintaining more cortical bone.
• A Human Biopsy (2.5 yrs after placement)The sharp and high alveolar crest (yellow arrow) could be maintained due to biology driven implant design. With this maintenance of alveolar bone, the peri-implant marginal gingiva showed almost no recession during 2.5 years of follow-up, even in the case of limited ridge width.
Performed Finite element analysis to evaluate the fixture-bone stress using ABAQUS 6.8 -R&D center in MegaGen Implant Co.,Ltd.(2009)-
Characteristics & Advantages » Ⅳ. Maintenance
II. Size
Small Ø3.5- Cover Screw included.• Availability of 7mm product is subject to local approval.• Europe certified only(CE). Not for Korean domestic
users.
Regular Ø4.0- Cover Screw included.• Availability of 7mm product is subject to local approval.• Europe certified only(CE). Not for Korean domestic
users.
Regular Ø4.5- Cover Screw included.• Availability of 7mm product is subject to local approval.
3.5
7 FANIHX3507C
8.5 FANIHX3508C
10 FANIHX3510C
11.5 FANIHX3511C
13 FANIHX3513C
15 FANIHX3515C
4.0
7 FANIHX4007C
8.5 FANIHX4008C
10 FANIHX4010C
11.5 FANIHX4011C
13 FANIHX4013C
15 FANIHX4015C
4.5
7 FANIHX4507C
8.5 FANIHX4508C
10 FANIHX4510C
11.5 FANIHX4511C
13 FANIHX4513C
15 FANIHX4515C
Fixture
Diameter (mm) Length(mm) Ref.C
Fixture
Diameter (mm) Length(mm) Ref.C
Fixture
Diameter (mm) Length(mm) Ref.C
4.0
4.4
4.9
L
L
L
2.8
3.3
3.3
3.5
4.0
4.5
Fixture Product & Package » II. SizeFixture Product & Package » I. Dimension
– 061060 AnyRidge®
[SEM image]
Fixture Product & Packaging » Ⅰ. Dimension
I. Dimension Fixture Product & Packaging
Ø3.3 3.53.8
4.0
Ø3.8 4.0 4.5
Ø4.0 4.25 4.75
Ø4.3 4.5 5.0
Ø4.8 5.0 5.5
Core(mm)
Platform(mm)
Bevel (mm)
Widest thread diameter is0.5mm wider than fixture size at 3.5mm0.4mm wider than fixture size at 4.0~8.0mm *For example Ø3.5 = Fixture diameter + 0.5mm Ø4.0~Ø8.0 = Fixture diameter + 0.4mm
Widest Thread Diameter
Bevel Diameter
Platform Diameter
Fixture Diameter
Narrow apical Diameter
Core
Length*Actual length of fixtureCore Ø3.3~4.3 fixture : 0.8mm shorter than the written lengthCore Ø4.8 fixture : 0.6mm shorter than the written length
Ø3.5 : 1.6mmØ4.0~5.5 : 1.8mmØ6.0~8.0 : 3.0mm
Important concept!It has been proven that 0.5~1.0mm subcrestal placement shows better crestal bone response. With AnyRigde system, a fixture goes down to the ideal position without further drilling avoiding damage to important anatomic structures.
Core diameter measured at 3.5mm under the platform
Platform Diameter
BevelDiameter
Female screw1.8mm diameter X 0.35mm pitch
Internal Hex : 2.3mm(Same in all fixtures)
3 different sizes - 3.5mm fixture : 3.5mm(platform) / 3.8mm(bevel) - 4.0~5.5mm fixture : 3.5mm(platform) / 4.0mm(bevel) - 6.0~8.0mm fixture : 5.0mm(platform) / 5.5mm(bevel)
Platform diameterBevel diameter
Ø6.0~Ø8.0 Ø4.0~Ø5.5 Ø3.5
Relationship between platform diameter and bevel diameter
Super Wide Ø7.5- Cover Screw included.
Super Wide Ø8.0- Cover Screw included.
7.5
7 FALIHX7507C
8.5 FALIHX7508C
10 FALIHX7510C
11.5 FALIHX7511C
13 FALIHX7513C
8.0
7 FALIHX8007C
8.5 FALIHX8008C
10 FALIHX8010C
11.5 FALIHX8011C
13 FALIHX8013C
Fixture
Diameter (mm) Length(mm) Ref.C
Fixture
Diameter (mm) Length(mm) Ref.C
L
L
8.4
7.9
4.8
4.8
8.0
7.5
Super Wide Ø7.0- Cover Screw included.
7.0
7 FALIHX7007C
8.5 FALIHX7008C
10 FALIHX7010C
11.5 FALIHX7011C
13 FALIHX7013C
Fixture
Diameter (mm) Length(mm) Ref.C
L
4.8
7.0
7.4
Fixture Product & Package » II. Size
Fixture Size
Wide Ø5.5- Cover Screw included.
Super Wide Ø6.0- Cover Screw included.
Super Wide Ø6.5- Cover Screw included.
Fixture Product & Package » II. Size
Wide Ø5.0- Cover Screw included.
5.5
7 FANIHX5507C
8.5 FANIHX5508C
10 FANIHX5510C
11.5 FANIHX5511C
13 FANIHX5513C
15 FANIHX5515C
6.0
7 FALIHX6007C
8.5 FALIHX6008C
10 FALIHX6010C
11.5 FALIHX6011C
13 FALIHX6013C
6.5
7 FALIHX6507C
8.5 FALIHX6508C
10 FALIHX6510C
11.5 FALIHX6511C
13 FALIHX6513C
Fixture
Diameter (mm) Length(mm) Ref.C
Fixture
Diameter (mm) Length(mm) Ref.C
Fixture
Diameter (mm) Length(mm) Ref.C
L
L
L
5.9
3.3
5.5
4.8
6.5
6.9
4.8
6.0
6.4
5.0
7 FANIHX5007C
8.5 FANIHX5008C
10 FANIHX5010C
11.5 FANIHX5011C
13 FANIHX5013C
15 FANIHX5015C
Fixture
Diameter (mm) Length(mm) Ref.C
3.3
5.0
5.4
L
Fixture Product & Package » III. Package
III. Package
Fixture Product & Package » II. Size
Additional AnyRidge Fixtures
L
L
5.4
5.9
4.0
4.0
5.0
5.5
AnyRidge has Core 4 Implant
4.0 4.0
Ø 3.5 Ø 4.0 Ø 4.5 Ø 5.0 Ø 5.5 Ø 6.0 Ø 6.5 Ø 7.0 Ø 7.5 Ø 8.0
2.8 3.3 3.3 3.3 3.3 4.8 4.8 4.8 4.8 4.8
This is a fixture that has improved the unstable elements in the current fixture line-up for safer dental implant practice in hard bone case; you will experience its excellence if you use it for following cases.
• If there is sufficient ridge or large osteotomy socket• If it is hard to place a deep-threaded fixture due to high bone density• If the habitual occlusal force of a patient is considered as higher than the average
Thin Ridge Normal Ridge
Core3.3
Core3.3
Core4.0
– 067066 AnyRidge®
Fixture Product & Packaging » Ⅲ. Packaging
Ⅲ. Packaging
Fixture
Cover Screw
Peel off cover & remove ampule
Make sure fixture is fully connected, then remove from ampule
Use hand driver to pick up cover screw
Place fixture according to drilling sequence
Tighten cover screw to fixtureSeparate fixture ampule from bottom, as shown, to reveal cover screw holder③
MegaGen ampule! Re-usable as building block *after cleaning and sterilization! less plastic waste!
Flip open top to reveal fixture
Connect handpiece to fixture
Separate top① & bottom②, as shown, to reveal inner ampule with fixture
①
③
②
→⤴
⤹
→
- Ampule
Wide Ø5.5_Core Ø4- Cover Screw included.
Wide Ø5.0_Core Ø4- Cover Screw included.
5.5
7 FANIHX5507SC
8.5 FANIHX5508SC
10 FANIHX5510SC
11.5 FANIHX5511SC
13 FANIHX5513SC
15 FANIHX5515SC
Fixture
Diameter (mm) Length(mm) Ref.C
5.0
7 FANIHX5007SC
8.5 FANIHX5008SC
10 FANIHX5010SC
11.5 FANIHX5011SC
13 FANIHX5013SC
15 FANIHX5015SC
Fixture
Diameter (mm) Length(mm) Ref.C
Abutment & Prosthetic Options » I. Fixture Level Prosthesis
(Refer to Page.260)
Cover Screw & Healing Abutment
– 067066 AnyRidge®
Cover Screw* Included in the fixture package.
• Use with a Hand Driver(1.2 Hex).• Used for submerged type surgery.• Protects the inner structure of a fixture.• Different heights can be chosen according to the position of fixture below the crest.• 1.6mm and 2.6mm height of Cover Screw
can be purchased separately.• Recommend torque : by hand (5 - 8Ncm)
Healing Abutment• Use with a Hand Driver(1.2 Hex).• Used for non-submerged type surgery or for
two stage surgery.• Choose appropriate diameter and height of
Healing Abutment according to situation.• Helps to form suitable emergence profile during period of gingival healing.• Recommend torque : by hand (5 - 8Ncm)
Ø3.5
0.8 AANCSF3508
1.6 AANCSF3516
2.6 AANCSF3526
Ø5.0 0.5 AANCSF5005
Ø6.0 0.5 AANCSF6005
Ref.C
Ø4.0
3 AANHAF0403
4 AANHAF0404
5 AANHAF0405
6 AANHAF0406
7 AANHAF0407
8 AANHAF0408
9 AANHAF0409
Ø5.0
3 AANHAF0503
4 AANHAF0504
5 AANHAF0505
6 AANHAF0506
7 AANHAF0507
8 AANHAF0508
9 AANHAF0509
Ø6.0
3 AANHAF0603
4 AANHAF0604
5 AANHAF0605
6 AANHAF0606
7 AANHAF0607
8 AANHAF0608
9 AANHAF0609
Ø7.0
3 AANHAF0703
4 AANHAF0704
5 AANHAF0705
6 AANHAF0706
7 AANHAF0707
8 AANHAF0708
9 AANHAF0709
Ø8.0
3 AANHAF0803
4 AANHAF0804
5 AANHAF0805
6 AANHAF0806
7 AANHAF0807
8 AANHAF0808
9 AANHAF0809
Ø10.0
3 AANHAF1003
4 AANHAF1004
5 AANHAF1005
6 AANHAF1006
7 AANHAF1007
8 AANHAF1008
9 AANHAF1009
Cover Screw & Healing Abutment
Height
ProfileDiameter Height
(mm) Ref.C ProfileDiameter
Height(mm) Ref.C
P.D
P.D
Platformlevel
H
Cover Screw & Healing Abutment
ProfileDiameter
Height(mm)
– 069068 AnyRidge®
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis
(Refer to Page.350)
Zirconia Abutment
CCM Abutment EZ Post Abutment Milling Abutment Angled Abutment
Temporary Abutment [Metal] Fuse Abutment
Lab Analog
Transfer Impression Coping Driver
(Refer to Page.352 )
Impression Coping [Transfer]
Impression Coping [Pick-Up]
Healing Abutment
Abutment Removal Driver
Cover Screw
Gold Abutment
Abutment & Prosthetic OptionsⅠ. Fixture Level Prosthesis
Zirconia Abutment
EZ Post Abutment Angled Abutment
Temporary Abutment [Metal] Fuse Abutment
Lab Analog
Transfer Impression Coping Driver
Impression Coping [Transfer]
Impression Coping [Pick-Up]
Healing Abutment
Abutment Removal Driver
Cover Screw
Gold Abutment
Temporary Abutment(Titanium)- Multi Post Screw(AANMSF) included.
• For making provisional restoration.• Grooved on the post allows strong resin adherence.• Recommend torque : 25Ncm
Fuse Abutment- Straight, 15°, 25° ; Multi Post Screw(AANMSF) included + Fuse Cap included.- Milling ; Multi Post Screw(AANMSF) included.
• Recommend torque : 25Ncm
Ø4.0 2Hex AANTMH4012T
Non-Hex AANTMN4012T
ProfileDiameter
Cuff Height(mm) Type Ref.C
Ø5.5
Ø5.5
3
5.5 Straight AFAP5535P
Ø4.5 715° AFAA5315P
25° AFAA5325P
Diameter
Labio-lingual
Mesio-distal
C.H(mm)
P.H(mm) Ref.CType
Ø4.0
Ø5.0
Milling
Mesio-distal
Mesio-distal
Labio-lingual
C.H
P.H
Labio-lingual
10
11
Platformlevel
Platformlevel
2
1
Hex
HexHex
Non-Hex
15° 25°
Lab AnalogØ3.5 Magenta AANLAF35
Ø4.0 ~ Ø5.5 Blue AANLAF4055
Ø6.0 ~ Ø8.0 Yellow AALLAF6080
Profile Diameter Color Ref.C
Abutment & Prosthetic Options » I. Fixture Level Prosthesis
Impression Coping (2-piece, Transfer Type)(For Closed-tray Technique)• Streamlined shape ; easy to transfer.• Anti-rotation grooves match with hex structure of fixtures.• Should be tightened with Impression Driver • Special impression coping screw which can be used
with a 1.2mm hex driver is available on request.
Impression Coping (1-piece, Transfer Type)(For Closed-tray Technique)• Should be tightened with Impression Driver• Special impression coping screw which can be used
with a 1.2mm hex driver is available on request.
Impression Coping (2-piece, Pick-up Type)(For Open-tray Technique)- Guide Pins : AANGPP0010 (7mm : Short) / AANGPP0015 (12mm : Long) / AANGPP0020 (20mm : Extra-long)
• Square structure ; strong anti - rotation function.• Designed for easy and accurate pick-up impression.• Extra-long guide pin can be purchased separately.
16
127
16
P.D
Abutment & Prosthetic Options » I. Fixture Level Prosthesis
Lab Analog & Temporary Abutments
Ø4.012
1-Piece
AANITN4012
16 AANITN4016
Ø5.012 AANITN5012
16 AANITN5016
Ø4.012
1-PieceHand driver
(1.2 Hex)
AANITN4012H
16 AANITN4016H
Ø5.012 AANITN5012H
16 AANITN5016H
Ø4.012
2-Piece
AANITH4012T
16 AANITH4016T
Ø5.012 AANITH5012T
16 AANITH5016T
Ø4.012
2-PieceHand driver
(1.2 Hex)
AANITH4012HT
16 AANITH4016HT
Ø5.012 AANITH5012HT
16 AANITH5016HT
ProfileDiameter
Height(mm) Type Ref.C
ProfileDiameter
Height(mm) Type Ref.C
Ø4.0
12
2-Piece
AANIPH4012T
16 AANIPH4016T
12 AANIPN4012T
16 AANIPN4016T
Ø5.0
7 AANIPH5007T
12 AANIPH5012T
7 AANIPN5007T
12 AANIPN5012T
12
3
P.D
Platformlevel
12
P.D
16
Platformlevel
ProfileDiameter
Height(mm) Type Ref.C
Impression Copings
EZ Post Abutment- Multi Post Screw(AANMSF/AANMST) included.
• Use with a Hand Driver (1.2 Hex).• Esthetic gold coloring.• Two different post heights. (5.5, 7.0mm)• Four different profile diameters.
(Ø4.0, 5.0, 6.0, 7.0)• Four different cuff heights.
(2.0, 3.0, 4.0, 5.0mm)• Recommend torque : 35Ncm
Abutment & Prosthetic Options » I. Fixture Level Prosthesis
force causing movement of 100μm on a fixture which was placed securely into adequate density of bone without defect. First, AnyRidge implants were placed into the internationally recognized standard bone block with more 40Ncm torque force and an abutment was connected on each implant. Instron equipment was used to measure the force to move a fixture 100μm. The average force was 220N (22.4 kgf). Therefore, if the new temporary abutment can be fractur under this force, it might protect the fixture from movement or failure.
From this experiment, we could developed a special temporary abutment which has lower fracture threshold of less than 200 N (20.4 kgf). It was named as Fuse Abutment. Also it has an anatomic profiles to make temporary prosthetics more esthetic.
Fuse Abutment ™
In 1992, Brunski JB. reported that the implant may has a higher possibility of fibrointergration than osseointegration between bone and implant surface when movements of more than100um occur on the fixture during osseointegration period. (John B. Brunski, Biomechanical factors affecting the bone-dental implant interface. Clinical Materials, Vol. 10, 153-201) Therefore, the implant was needed to protected not to move when immediate loading is carried out. However, it is not easy to manage loading on the fixture, even when we used a resin temporarily with a titanium cylinder. It was thought that it was partly because of the metal component of temporary cylinder, which can deliver excessive forces to the fixture. This was one of the reasons which made clinicians hesitate the immediate loading procedure. So it was necessary to develop a special temporary cylinder. It should have been broken under the force which could lead fibrointegration or failure of osseointegration to protect the fixture. and it would be preferred if it was easy to make a temporary crown on this particular temporary cylinder. We tried to measure the
Similar to acustomized abutmentfor excellent esthetics!
Perfect margin fitwith a prosthetic cap
Scalloped outline
Various Angle :Straight 15° 25°
S-line
Elliptical Occlusal view like a natural tooth
Average < 180N
Disp
lacem
ent(m
m)
Force(N)
Micro-movement test of implant
Fuse Abutment
area
0 50
0.1
0.2
0.3
0.4
0.5
100 150 200 250 350 400 450 500
D1
D2
D3
D4
300
Com
pres
sive
stre
ngth
(N)
Displacement(mm)
Compressive strength test of Fuse Abutment
0
50
100
150
200
250
1 2
Specimen 2Specimen 3Specimen 4Specimen 5
Specimen 1
Design concept of Fuse Abutment™
Why ‘Fuse Abutment’ is the essential partner for a temporary crown?
Rationale of Fuse Abutment™
Mesio-distal
Labio-lingual
Performed compressive strength test to evaluate the micro movement for bone density using universal testing machine -R&D center in Megagen Implant Co.,Ltd.(2012)-
Performed compressive strength test to evaluate the yield strength for Fuse Abutment using universal testing machine-R&D center in Megagen Implant Co.,Ltd.(2012)-
Abutment & Prosthetic Options » I. Fixture Level Prosthesis
Ø4.0
2
5.5
Hex
AANEPH4025L
3 AANEPH4035L
4 AANEPH4045L
5 AANEPH4055L
2
7
AANEPH4027L
3 AANEPH4037L
4 AANEPH4047L
5 AANEPH4057L
Ø4.0
2
5.5
Non-Hex
AANEPN4025L
3 AANEPN4035L
4 AANEPN4045L
5 AANEPN4055L
2
7
AANEPN4027L
3 AANEPN4037L
4 AANEPN4047L
5 AANEPN4057L
Ø5.0
2
5.5
Hex
AANEPH5025L
3 AANEPH5035L
4 AANEPH5045L
5 AANEPH5055L
2
7
AANEPH5027L
3 AANEPH5037L
4 AANEPH5047L
5 AANEPH5057L
Ø5.0
2
5.5
Non-Hex
AANEPN5025L
3 AANEPN5035L
4 AANEPN5045L
5 AANEPN5055L
2
7
AANEPN5027L
3 AANEPN5037L
4 AANEPN5047L
5 AANEPN5057L
Ø6.0
2
5.5
Hex
AANEPH6025L
3 AANEPH6035L
4 AANEPH6045L
5 AANEPH6055L
2
7
AANEPH6027L
3 AANEPH6037L
4 AANEPH6047L
5 AANEPH6057L
Ø6.0
2
5.5
Non-Hex
AANEPN6025L
3 AANEPN6035L
4 AANEPN6045L
5 AANEPN6055L
2
7
AANEPN6027L
3 AANEPN6037L
4 AANEPN6047L
5 AANEPN6057L
Ø7.0
2
5.5
Hex
AANEPH7025L
3 AANEPH7035L
4 AANEPH7045L
5 AANEPH7055L
2
7
AANEPH7027L
3 AANEPH7037L
4 AANEPH7047L
5 AANEPH7057L
Ø7.0
2
5.5
Non-Hex
AANEPN7025L
3 AANEPN7035L
4 AANEPN7045L
5 AANEPN7055L
2
7
AANEPN7027L
3 AANEPN7037L
4 AANEPN7047L
5 AANEPN7057L
ProfileDiameter
CuffHeight(mm)
Post Height(mm) Type Ref.C
P.D
P.H
C.H
Platformlevel
Hex Non-Hex
ProfileDiameter
CuffHeight(mm)
Post Height(mm) Type Ref.C
Abutment Options (Continued)
Angled Abutment- Multi Post Screw(AANMSF/AANMST) included.
• Two different angulations. (15°, 25°)• Four different profile diameters.
(Ø4.0, 5.0, 6.0, 7.0)• Four different cuff heights. (2, 3, 4, 5mm)• Can cover 12 different directions.
[six to the surface(Hex), six to the edge of hex(Hex-E)]
• Esthetic gold coloring.• Minimized screw head length needs minimum
height to prevent milling problems.• Recommend torque : 35Ncm
Abutment & Prosthetic Options » I. Fixture Level Prosthesis
Gold Abutment - Multi Post Screw(AANMSF/AANMST) included.
• Useful to make a customized abutment in difficult situations.
• Precious only.• Melting point of gold alloy : 1400 - 1450°C• Threaded sleeves for convenient Resin / Wax-up.• Recommend torque : 30Ncm
Abutment & Prosthetic Options » I. Fixture Level Prosthesis
Ø4.0
2
7
Hex
15°
AANAAH4215L
3 AANAAH4315L
4 AANAAH4415L
5 AANAAH4515L
2
Hex-E
AANAAE4215L
3 AANAAE4315L
4 AANAAE4415L
5 AANAAE4515L
2
Hex
25°
AANAAH4225L
3 AANAAH4325L
4 AANAAH4425L
5 AANAAH4525L
2
Hex-E
AANAAE4225L
3 AANAAE4325L
4 AANAAE4425L
5 AANAAE4525L
Ø5.0
2
7
Hex
15°
AANAAH5215L
3 AANAAH5315L
4 AANAAH5415L
5 AANAAH5515L
2
Hex-E
AANAAE5215L
3 AANAAE5315L
4 AANAAE5415L
5 AANAAE5515L
2
Hex
25°
AANAAH5225L
3 AANAAH5325L
4 AANAAH5425L
5 AANAAH5525L
2
Hex-E
AANAAE5225L
3 AANAAE5325L
4 AANAAE5425L
5 AANAAE5525L
Ø6.0
2
7
Hex
15°
AANAAH6215L
3 AANAAH6315L
4 AANAAH6415L
5 AANAAH6515L
2
Hex-E
AANAAE6215L
3 AANAAE6315L
4 AANAAE6415L
5 AANAAE6515L
2
Hex
25°
AANAAH6225L
3 AANAAH6325L
4 AANAAH6425L
5 AANAAH6525L
2
Hex-E
AANAAE6225L
3 AANAAE6325L
4 AANAAE6425L
5 AANAAE6525L
Ø7.0
2
7
Hex
15°
AANAAH7215L
3 AANAAH7315L
4 AANAAH7415L
5 AANAAH7515L
2
Hex-E
AANAAE7215L
3 AANAAE7315L
4 AANAAE7415L
5 AANAAE7515L
2
Hex
25°
AANAAH7225L
3 AANAAH7325L
4 AANAAH7425L
5 AANAAH7525L
2
Hex-E
AANAAE7225L
3 AANAAE7325L
4 AANAAE7425L
5 AANAAE7525L
ProfileDiameter
CuffHeight(mm)
Post Height(mm) Type Angle Ref.C
P.D
15° 15°25° 25°
P.H
C.H
Platformlevel
Hex-E Hex
ProfileDiameter
CuffHeight(mm)
Post Height(mm) Type Angle Ref.C
Ø4.0 1 11Hex AANGAH4012L
Non-Hex AANGAN4012L
ProfileDiameter
CuffHeight(mm)
Post Height(mm) Type Ref.C
Hex Non-Hex
P.H
C.H
P.D
Platformlevel
Abutment Options (Continued)
CCM Abutment - Multi Post Screw(AANMSF/AANMST) included.
• Useful to make a customized abutment in difficult situations. • Can be casted with non-precious alloys(Ni-Cr, Cr-Co alloys). • Non-precious melting temperature : Depend on Manufacturer• Threaded sleeves for convenient Resin / Wax-up. • Melting temperature of CCM : 1380 - 1420°C• Recommend torque : 35Ncm
Extra EZ Post Abutment- Multi Post Screw(AANMSF/AANMST) included.
• Only when satisfactory emergence profile cannot be obtained due to thin gingiva or shallow positioned fixture.
• Useful when fixture is exposed over the gum line.• AANEEH3335 used for fixture (ø4.0~5.5)• AANEEH4035 used for fixture (ø5.0, ø5.5_Core ø4)
- AANEEH4035 is for the Core Diameter ø4.0mm (Fixture Diameter ø5.0~5.5mm). It also can be used for Fixture Diameter ø 6.0~8.0mm for platform switching.
• AANEEH4835 used for fixture (ø6.0~8.0)• Recommend torque : 35Ncm
Ø3.3
3 5.5
Bevel AANEEH3335L
Ø4.0Platform
AANEEH4035L
Ø4.8 AANEEH4835L
CoreDiameter
Cuff Height
Post Height Type Ref.C
Bevel Platform Platform
5.5 5.5 6.5
P.H
C.H
Platformlevel
Ø4.0 1 11Hex AANCAH4012L
Non-Hex AANCAN4012L
ProfileDiameter
CuffHeight(mm)
Post Height(mm) Type Ref.C
Hex Non-Hex
P.H
C.H
P.D
Platformlevel
– 093092 AnyRidge®
Multi-unit Abutment[Straight]
Multi-unit AngledAbutment [17°]
Multi-unit AngledAbutment [30°]
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
CCM Cylinder
Scan Abutment
Temporary Cylinder
Impression Coping Lab Analog
ZrGen Abutment
For the design concept and rationale of the Multi-unit Abutment, Please refer to page.094
Ⅱ. Abutment Level Prosthesis3-1. Multi-unit Abutment & Components (All-on-4) (N_Type)
[Regular] [Wide]Healing Cap
(Refer to Page.098)
– 095094 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
▸▸ Multi-unit AbutmentTM
Multi-unit Abutment Design Concept
MegaGen Implant develops the special abutment named as Multi-unit Abutment, which can be the solution for the edentulous patients. With 4 fixtures placed into patient’s ridge and a hybrid denture on those four fixtures, a patient can recover his or her dental condition almost completely. In most cases, Multi-unit Abutments work in a set of 2 x straight type abutment for anterior position and 2 x angled type abutment on posterior position.
Features
You could see how Multi-unit Abutment functions and what benefits you could get from Multi-unit Abutment are as the followings:
• 2 fixtures which are slantly implanted on posterior position are osseointegrated with cancellous bone. These fixtures function as dispersing vertical load on alveolar bone.
• Multi-unit Abutment is only 4 fixtures + 4 abutments. It means that dental surgeon has enough places for surgery. Therefore, it will be easy to find and place 4 fixtures into ridge where abundant cancellous bone exists.
• A doctor can use graft bone material if a patient dosen’t have enough alveolar bone. However, the slantly placed fixtures can overcome the patient’s insufficient bone by getting good holding strength with this angulation.
• In addition, these angulated fixtures can avoid touching important anatomies, such as mandibular nerve and maxillary sinus.
• All on 4 technique is also possible to do guided surgery using R2GATE Guide with a diagnosis from R2GATE.
Abutment & Prosthetic Options » II. Abutment Level ProsthesisAbutment & Prosthetic Options » II. Abutment Level Prosthesis
II. Abutment Level Prosthesis Multi-unit Abutment & Components (All-on-4) (N_Type)
For the design concept and rationale of the Multi-unit Abutment.
– 095094 AnyRidge®
▸▸ Multi-unit Abutment N Type
The solution for the edentulous patients
Benefit Available implant System
Compatibility with others’ Multi-unit level prosthetic components
1. Easy and economical treatment solution for compromised edentulous cases.2. Expensive and time consuming bone graft may not be necessary.3. Multiple angles (0˚, 17˚, 30˚) support different implant insertion paths.4. Universally compatible with other Multi- unit systems.
- AnyRidge Internal- AnyOne Internal- AnyOne External
✓ Post Height ✓ Post Diameter ✓ Post Angle ✓ Abutment Angle ✓ Cuff Height
Prosthetics compatibilityNobel Abutment
Various AnglesStraight, 17°, 30°
ConnectionAnyRidge Internal
AnyOne Internal, External
Post Platform Diameter Ø4.8
Post Height 2.2mm
Various CuffsInternalStraight :1.5, 2.5, 3.5, 4.5mm17°: 2.5, 3.5mm30°: 3.5, 4.5mm
ExternalStraight :1, 2, 3, 4, 5mm17°: 2, 3, 4mm30°: 4, 5mm
Post Angle 44˚
Post Diameter Ø4
– 097096 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
➲ Multi-unit Abutment
1.5
1-piece(M1.8)
MUAARN0015C
2.5 MUAARN0025C
3.5 MUAARN0035C
4.5 MUAARN0045C
2.5
Hex
MUAARH1725LC
3.5 MUAARH1735LC
4.5 MUAARH1745LC
2.5
Non-Hex
MUAARN1725LC
3.5 MUAARN1735LC
4.5 MUAARN1745LC
Multi-unit Abutment [AR] - Straight- MUA Straight Carrier (MUASC) included• Recommend torque : 35Ncm
Multi-unit Angled Abutment [AR] - 17°- MUA Screw (MUAARS) included- MUA Angled Carrier (MUAAC) included• Recommend torque : 25Ncm
Multi-unit Angled Abutment [AR] - 30°- MUA Screw (MUAARS) included- MUA Angled Carrier (MUAAC) included• Recommend torque : 25Ncm
Cuff Height (mm)
Cuff Height (mm)
Type
Type
Ref.C
Ref.C
3.5Hex
MUAARH3035LC
4.5 MUAARH3045LC
3.5Non-Hex
MUAARN3035LC
4.5 MUAARN3045LC
Cuff Height (mm) Type Ref.C
Ø4.8
C.H
C.H
17°
C.H
30°
Abutment & Prosthetic Options » II. Abutment Level ProsthesisAbutment & Prosthetic Options » II. Abutment Level Prosthesis
– 097096 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
Impression coping (Pick-up)- Guide pin (MUAGP) included• Use to take an impression at the abutment level.• Open tray method.
Non-Hex MUAICT
Multi-unit Abutment(Nobel) MUALA
Connection Ref.C
Head form Ref.C
➲ Components for Multi-unit Abutment (Continued)
11.2
Ø4.8
2.2 44°
1510.7
2
Ø4.8
Lab Analog• Use to duplicate the Multi-unit abutment in the working
model.• Available to use as a RP Analog for 3D printed working
model.
CCM Cylinder- Cylinder Screw (MUAS) 2EA included Non-Hex MUACCML
Connection Ref.C 15
3.4
M1.4
Ø3.3
Ø4.8
Temporary Cylinder- Cylinder Screw (MUAS) included Non-Hex MUATCL
Connection Ref.C 12
3.4
M1.4
Ø3.3
Ø4.8
• Use for fabricating acrylic provisional restoration.• Grooves on the post cylinder allow storing resin adhension.• Back-up screw is included.• Recommend torque : 15Ncm
• Use for fabricating screw retained prostheses with metal reinforced or bar structured overdentures.• Available to cast with non-precious dental alloys
(Ni-Cr, Cr-Co alloys)• Melting temperature of CCM base: 1380 - 1420℃• Back-up screw is included.• Recommend torque : 15Ncm
– 099098 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
Healing Cap Set reference codeOrder code : Add “P” after the existing reference codeEx) MUAHCL → MUAHCP
Regular MUAHCL
Wide MUAHCWL
Type Ref.C Healing Cap- Cylinder Screw (MUAS) 2ea included • The size of healing cap can be selected
depending on soft tissue volume or type of restorations.
Regular Wide
4.2 1.71.5 3.4
Ø4.9 Ø4.9Ø6.8
M1.4
Try-in Abutment Set reference codeOrder code : MUTIAAR00P
※ Available Systems : AnyRidge, AnyOne Internal, AnyOne External ※ Kit contains Straight, 17˚ and 30˚ type of Try-in Abutments (1 each)
Try-in Abutment• Cuff height is indicated with laser markings• Straight17˚, 30˚• Non-hex type
Straight 17˚ 30˚
1.52.53.54.5
Straight 1.5 / 2.5 / 3.5 / 4.5 MUTIAAR00C
17˚ 2.5 / 3.5 / 4.5 MUTIAAR17C
30˚ 3.5 / 4.5 MUTIAAR30C
Angle Cuff Marking Ref.C
➲ Components for Multi-unit Abutment
Abutment & Prosthetic Options » II. Abutment Level ProsthesisAbutment & Prosthetic Options » II. Abutment Level Prosthesis
– 099098 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
2.0 10 MUD10
1.2 20 MUHD1220
1.2 20 MUARD20
2.0 10 MURAD10
Hex
Hex
Hex
Hex
Length
Length
Length
Length
Ref.C
Ref.C
Ref.C
Ref.C
10
20
Ø4.4
10
20
20
24
29
29
Ø4.4
Hex1.2
Hex1.2
M2.0
Multi-unit Driver• Use to torque straight type Multi-unit Abutments.• Use with a torque wrench (ref code: MTW300A)
Right Angle Driver• Use to torque straight type Multi-unit Abutments.• Use with latch-type handpiece.• Use with Meg-TORQ (ref code: MEG_TORQ)
Hand Driver• Use for abutment screw with 1.2 hex hole.• Use up to 15˚ divergent.• It should use under 30Ncm torque.
Removal Driver • Use for abutment screw with 1.2 hex hole.• Use up to 15˚ divergent.• Exclusively for AnyRidge system.• It should use under 30Ncm torque.
Abutment & Prosthetic Options » II. Abutment Level Prosthesis
– 101100 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
• Abutment Screw (M1.8 & M2.0) : 25Ncm • Cylinder Screw (M1.4) : 15Ncm • Straight Abutment (M1.8 &M2.0) : 35Ncm
Instruction for removing abutment screw from Multi-unit abutment [Exclusively for AnyRidge system]
1. Completely unscrew abut- ment screw by rotating it counterclock wise (approxi- mately 4 rotations are required). It should sue with a Hand Driver (ref code: MUHD1220)
2. Pull the Hand Driver up straight until it is visible through abut- ment crew hole. Shaking left and right may be required if the screw becomes stuck inside of the abutment hole.
3. Slightly rotate the screw to the main access hole. Otherwise the screw could fall back into the screw hole due to distur bance of abutment structure.
4. Remove abutment with the Removal Driver (ref code: MUARD20) by rotating it clockwise.
Driver Tightening Torque Guide
1. Multi-unit Abutment Remover Driver
FractureLocation
< 30Ncm < 30Ncm
FractureLocation
2. Multi-unit Hand Driver
• Excessive torque more than 30Ncm may cause fracturing of the driver.• Straight type Multi-unit abutment needs to use the Multi-unit Driver that is provided in the starting package. (ref code: MUD10)• Strongly recommended to pick up the abutment screw by pressing the Hand Driver to remove the abutment screw from the
Multi-unit abutment.
▸▸ Screw & Abutment Tightening Torque Guide
Abutment & Prosthetic Options » II. Abutment Level Prosthesis
– 101100 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
30º 7 MUSG70
Angle Marking Length(mm) Ref.CSurgical Guide
• The distance between the lines is 7mm• Put center pin after initial drilling at the centric
of arch. (Refer to the surgical protocol on page.104)
770
14
10
30˚
Ø2.0
▸▸ How to use Surgical Guide
※ As Canine and second premolar are most commonly used, the surgical guide has thicker lines for easier identification. ※ The surgical guide is able to use for first molar depending on surgical plan.
Bend to use
[Packing]
LabelProduct
Instruction for use
2 35
4
6
➲ Components for Multi-unit Abutment
Abutment & Prosthetic Options » II. Abutment Level Prosthesis
– 103102 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
▸▸ Multi-unit Abutment Set Contents
Straight
AnyRidge
Angle 17˚ Angle 30˚
Cuff 1.5mm2.5mm3.5mm4.5mm
Cuff 2.5mm 3.5mm 4.5mm
Cuff 3.5mm 4.5mm
Impression Coping
Lab Analog
Temporary Cylinder
HealingCap
(Regular)OR CCM
Cylinder
Multi-unit Abutment Healing cap type Set reference codeOrder code : Add “HP” after the existing reference codeEx) MUAARH1725LC → MUAARH1725 HP
Multi-unit Abutment CCM type Set reference codeOrder code : Add “P” after the existing reference codeEx) MUAARH1725LC → MUAARH1725 P
Abutment & Prosthetic Options » II. Abutment Level Prosthesis
– 105104 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
▸▸ Surgical ProtocolConventional Surgery
1. Initial drilling 2. Guide Bending & Position
8. Impression 9. Healing Cap
7. Tightening the AbutmentAbutment Screw tighten-ing Torque : 25Ncm After connecting Abutment Screw, remove Carrier from Abutment. For 17 ̊ abut-ment, you need to tighten it by tilting Driver about 5.̊ Connect Abutment and check the path using Carrier.
Straight Abutment tight-ening Torque : 35Ncm After removing Carrier, connect Abutment to the Fixture using Right Angle Driver or MUA Driver.
For placement of center pin after initial drilling in the centric of the arch. The drill-ing hole should be in lingual area of the arch to ensure the best result.
Bend according to the patient’s arch.
Take an impression with an individual tray. (Open tray method is strongly recom-mended to avoid any error in the future.)
Cylinder Screw tighten-ing Torque : 15NcmPlace Healing Cap on top of Multi-unit abutment, and connect Cylinder Screw with the Hand Driver.
– 105104 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
3. Drilling
6. Abutment Selection
10. Suture
Drill according to the surgical plan.
4. The fixture is implantedPlace implant fixtures ac-cording to the surgical plan and do not exceed torque value (60Ncm)
Select the appropriate set after checking the angu-lation and cuff height that were measured with the Try-in abutment. Con-nect the abutment onto the fixture and check the angulation and the cuff height.
5. Try-in AbutmentUsing the laser marking on the Try-in abutment, select the appropriate cuff height and angulation of Multi-unit abutments.
– 107106 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
▸▸ Surgical ProtocolGuided Surgery
1. GuidePlace a R2GATE Guide.
2. Narrow Crest Drill
9. Connect Temporary Cylinder in the back
10. Setting Temporary and Denture
8. Setting Temporary and Denture 7. Connect Temporary Cylinder in the frontReline the temporary denture with resin to fill the space around the Temporary Cylinder.
Connect the Temporary Cylinders in the front. Make sure that holes in the denture are free from any contact with the Temporary Cylinder. Adjust the holes until there is no contact between the denture and the Temporary Cylinder. *If the Temporary Cylinder is fixed using Guide Pin, resin flow into access hole will be prevented.
For the cases with narrow ridge or placing a fixture slanted on the lingual side, you can flatten the surface and drill stably without slipping
Connect rest of the Temporary Cylinders in the back, make sure that the holes in the denture are free from any contact with the Temporary Cylinder. Adjust the holes until there is no contact between the denture and the Tempo-rary Cylinder.
All temporary cylinders are picked up in the denture with resin.
– 107106 AnyRidge®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis
3. DrillingDrill according to the drilling sequence.
4. Fixture Placement
5. Try-in Abutment6. Abutment Selection
13. Finish11. Temporary Fixation 12. Tighten the Denture
Select the appropriate set after checking the angulation and cuff height that were measured with the Try-in abutment. Connect the abutment onto the fixture and check the angulation and the cuff height.
Using the laser marking on the Try-in abutment, select the appropriate cuff height and angulation of Multi-unit abutments.
Remove Denture and fill up the bottom and other non-resin filled parts with resin and completely fix Temporary Cylinder.
Cylinder Screw tightening Torque : 15Ncm Set Denture onto Multi-unit Abutment and tighten cylinder
Close Hole using EZ Seal and finalize the surgery.
– 127126 AnyRidge®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis
Retentive Cap set (Dynamic)
Retentive Cap set
Lab Analog
Impression Coping
Meg-Rhein Abutment
Ⅲ. Overdenture Prosthesis5. Meg-Rhein Abutment & Components
– 127126 AnyRidge®
➲ Meg-Rhein Overdenture System
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis
Meg-Rhein Overdenture System- 1 Meg-Rhein Abutment- 1 Plastic Impression Coping- 1 Stainless Steel Housing- 1 Protective Disk- 5 Retentive Caps (Black-Lab, Yellow-0.6kgf, Pink-1.2kgf, White-1.8kgf, Violet-2.7kgf)
• Perfect compatibility with the Rhein83 from Italy.• Recommend torque : 15Ncm.
0 ADR00P
1.0 ADR01P
2.0 ADR02P
3.0 ADR03P
4.0 ADR04P
5.0 ADR05P
6.0 ADR06P
Cuff Height (mm) Ref.C
C.H
Stainless Steel Housing & Black Cap
Meg-Rhein Abutment with Plastic Impression Coping
Yellow Cap & Pink Cap
White Cap & Violet Cap
Protective Disk
8.8
Meg-Rhein Overdenture System(Dynamic)- 1 Meg-Rhein Abutment- 1 Plastic Impression Coping- 1 Stainless Steel Housing (Dynamic) & Black-Lab- 1 Protective Disk- 4 Retentive Caps (Yellow-0.6kgf, Pink-1.2kgf, White-1.8kgf, Violet-2.7kgf)
• Perfect compatibility with the Rhein83 from Italy.• Recommend torque : 15Ncm.
0 ADR00PA
1.0 ADR01PA
2.0 ADR02PA
3.0 ADR03PA
4.0 ADR04PA
5.0 ADR05PA
6.0 ADR06PA
Cuff Height (mm) Ref.C
C.H
Stainless Steel Housing (Dynamic) & Black Cap
Meg-Rhein Abutment with Plastic Impression Coping
Yellow Cap & Pink Cap
White Cap & Violet Cap
Protective Disk
8.8
– 129128 AnyRidge®
▸▸ Overdenture System
Advantages
4.4mm 4.8mm
2.1mm 2.2mm
30º
Violet(2.7kgf)
White(1.8kgf)
Pink(1.2kgf)
Yellow(0.6kgf)
Small & Easy-to-Use Housing System
Normal Dynamic
Tilting Angle
Various Retentive Caps of the Meg-Rhein
Low Reduction Rate & Uniform Variance of Retentive Force
50º
100
80
60
40
20
0Meg-Rhein Product K
Before After (1,000cycles)
Product L Product P
Ret
entiv
e fo
rce
(kgf
) 3
2
1
01,000 Cycles
R2=0.85
27%
7349%
51
38%
62
37%
63
R2(Coefficient of determination) becomes more reliable when it is close to “1”.
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis
– 129128 AnyRidge®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis
➲ Components for Meg-Rhein Abutment
Stainless Steel Housing• 5ea/pack MHP
Ref.C
RCVP
Ref.C Retentive Caps (Violet)• Violet cap(2.7kg) - For refill (5ea/pack).• Can be used for more retentive force following
white cap(1.8kgf).
RCWP
Ref.C Retentive Caps (White)• White cap(1.8kg) - For refill (5ea/pack).• Can be used for more retentive force following pink
cap(1.2kgf).
RCPP
Ref.C Retentive Caps (Pink)• Pink cap(1.2kgf) - For refill (5ea/pack).
RCYP
Ref.C Retentive Caps (Yellow)• Yellow cap(0.6kgf) - For refill (5ea/pack).
RCBP
Ref.C Retentive Caps (Black)• For laboratory
Stainless Steel Housing (Dynamic)• 5ea/pack
THP
Ref.C
– 131130 AnyRidge®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis
Stainless Impression Coping (Pick-Up)• 2ea/pack.• Italy - Rhein 83 products.• For accurate (pick-up type) impression.• Metal with groove design to prevent from swaying.
044CAIN
Ref.C 5.5
085IAC
Ref.C
83
40
Retentive Cap Insertion Tool• Retentive Cap insertion tool.
091EC
Ref.C
90
Retentive Cap Removal Tool• Retentive Cap removal tool.
PLA
Ref.C Lab Analog
– 131130 AnyRidge®
Why will AnyRidge work in any ridge?
Wider fixture in a narrow crestTo maximize long term survival of implants.
Narrow upperdiameter To maximize preservation by minimizing stress on the cortical bone.
Knife-Threads· For smooth insertion and stronger primary stability. · No cuting edge for minimum invasion. · Ideal for soft bone cases.
Narrow apicaldiameter For easier fixture insertion into a narrow ridge split incision
Tapered bodyExcellent for simple installationand Immediate loading.
· For faster, stronger osseointegration.· New surface technology incorporating Ca2+ ions on the SLA treated surface.· 100% elimination of any remaining acid from the conventional SLA process.
final restoration
Case1 Case2
– 347346
Hand DriverRatchet Connector
Ratchet Connector
HandpieceConnector
HandpieceConnector
Cortical Bone Drill
Torque WrenchTorque Wrench
Lance Drill
Drill Extension
Path Finder(for pre-placed fixtures)
Direction Indicator(for osteotomy sockets)
Path Finder(for pre-placed fixtures)
Direction Indicator(for osteotomy sockets)
Abutment Removal Driver
Abutment Removal Driver
Trephine BurPoint Trephine Bur
llirD gni kr aM
llir D gni kr aM
llir D r eppot S
Cortical Bone Drill
Drill Extension
Lance Drill
Hand Driver
Ratchet
AnyRidge Kit » Ⅱ. Surgical Kit
Ⅱ. AnyRidge Surgical Kit : Full Type
KARIN3001
Ref.C
Easier and safer to drill for the depth as you need with the stopper drills.
MegaGen Kit – 347346
Ø2.0 Long MGD100L
Diameter Type Ref.C
Ø2.0
18
TANTDF2018
Ø2.5 SD2518S
Ø2.8 SD2818S
Ø3.3 TANSDF3318
Ø3.8 TANSDF3818
Ø4.3 TANSDF4318
Ø4.8
15
TANSDF4815
Ø5.4 TANSDF5415
Ø5.9 TANSDF5915
Diameter Length (mm) Ref.C
Ø2.0
7 TANTDF2007
8.5 TANTDF2008
10 TANTDF2010
11.5 TANTDF2011
Ø2.8
7 SD2807M
8.5 SD2808M
10 SD2810M
11.5 SD2811M
Ø3.3
7 TANSDF3307
8.5 TANSDF3308
10 TANSDF3310
11.5 TANSDF3311
Ø3.8
7 TANSDF3807
8.5 TANSDF3808
10 TANSDF3810
11.5 TANSDF3811
Ø4.3
7 TANSDF4307
8.5 TANSDF4308
10 TANSDF4310
11.5 TANSDF4311
Ø4.8
7 TANSDF4807
8.5 TANSDF4808
10 TANSDF4810
11.5 TANSDF4811
L
L
D
Diameter Length (mm) Ref.C
AnyRidge Kit » Ⅱ. Surgical Kit
Lance Drill• Useful to make an indentation on cortical bone to confirmtheexactdrillinglocation.
Marking Drill• Eachdrillhascalibrationsfrom7.0to18.0mm.(TANSDF4815,TANSDF5415,TANSDF5915have calibrationsupto15.0mm)
• Easy to recognize by dual marking systems.(Grooveandlasermarking)
StopperDrill
➲ Surgical Kit Components
2.0
1510
L
D
AnyRidge ® Surgical Kit » I. Surgical KitAnyRidge ® Surgical Kit » I. Surgical Kit
– 349348
7(7.5)
8.5(9)
10(10.5)
11.5(12)
13(13.5)
Ø5.0 (In.Ø4.0) SPTB4050
Diameter Ref.C
5.0
D
Ø3.5 TANCDL3500
Ø4.0~ Ø5.5 TANCDL4055
Ø6.0~ Ø8.0 TANCDL6080
Diameter Ref.C
Diameter 1Diameter 2
Ø3.5 (in Ø2.5)
Short(32mm)
TANTBL2535
Ø5.0 (in Ø4.0) TANTBL4050
Ø6.0 (in Ø5.0) *TANTBL5060
Ø7.0 (in Ø6.0) *TANTBL6070
Ø3.5 (in Ø2.5)
Long(38mm)
*TANTBE2535
Ø5.0 (in Ø4.0) *TANTBE4050
Ø6.0 (in Ø5.0) *TANTBE5060
Ø7.0 (in Ø6.0) *TANTBE6070
Diameter Type Ref.C
Type
AnyRidge Kit » Ⅱ. Surgical Kit
➲ Surgical Kit Components (Continued)
PointTrephineBur
CorticalBoneDrill• Removescorticalboneandenlargesosteotomysocketespeciallyathardbone.
• Similarfunctionwithcountersinkdrillofothersystems.
• Eachdrillhastwostepsofdiameterforconvenience.
TrephineBur• Minimizesthedrillingstepsneeded,especiallyforwiderfixtures.
• Helpfulforcollectingautogenousbone.• Usefulforremovingfailedandfracturedfixtures.• Depthmarkingsare7,8.5,10,11.5,13mm,samedepthsasfixtures.(NoYdimensionsomarkingsareactuallength).
• Markingsonthedrillshaftrepresenttheinside/outsidediameterofTrephineBurs.
(*)Separatesalesitem.3.5,5.0TrephineBurareincludedinSurgicalkit.
MegaGen Kit – 349348
5 *Ultra short TANHCU
10 Short TANHCS
15 Long TANHCL
10 Short (MiNi) HCS17
15 Long (MiNi) HCL17
6 *Ultra short TANREU
10 Short TANRES
15 Long TANREL
15 Short(MiNi) RCS17
20 Long (MiNi) RCL17
Length (mm) Type Ref.C
Length (mm) Type Ref.C
5 *Ultra-short TCMHDU1200
10 Short TCMHDS1200
15 Long TCMHDL1200
20 *Extra-long TCMHDE1200
TypeLength(mm) Ref.C
L
L
L
Ultrashort
Ultrashort
Option
Option
Option
Option
Short
Short
Long
Long
MiNi
MiNi
AnyRidge Kit » Ⅱ. Surgical Kit
RatchetConnector• DeliverstorquefortheplacementorremovalofafixturewithaRatchetWrench.
• SecureaRatchetExtensionorTorqueWrenchtoafixturebeforeexertingforce.
• Toomuchtorqueforcecanresultadamagetothehexofafixture.
• Marksontheshaftcanindicatethepositionoffixtureplatform,especiallyforflaplesssurgery.
HandpieceConnector• Deliverstorquefortheplacementofafixturewithahandpiece.
• Easyandsecurepick-upanddelivery.• Usedtoplaceanimplantwithoutamount.• Marksontheshaftcanindicatethepositionoffixtureplatform,especiallyinflaplesssurgery.
Hand Driver (1.2Hex)• UsedforallCoverScrews,allAbutmentScrews
and all Healing Abutments.• Availablein4lengthsforconvenience.• HandDrivercanbedirectlyinsertedintotheTorqueWrenchwithoutusinganadapter.
• Hextipcanwithstand35-45Ncmoftorquewithoutdistortion.
(*)Separatesalesitem.
(*)Separatesalesitem.
(*)Separatesalesitem.
AnyRidge ® Surgical Kit » I. Surgical KitAnyRidge ® Surgical Kit » I. Surgical Kit
– 351350
17.5 TANMRD18
25.0 *TANMRD25
Length (mm) Ref.C
MDE150
Ref.C
Ø2.0 / Ø2.8 MDI100
Ø3.2 / Ø4.7 MDI3348
Length (mm) Ref.C
10 TANPFF3580
Length (mm) Ref.C
Torque Wrench MTW300AT
*Torque Wrench Adapter(Handpiece) TTAI100
Torque Wrench Adapter(Ratchet) TTAR100
Type Ref.C
Handpiece Ratchet
AnyRidge Kit » Ⅱ. Surgical Kit
➲ Surgical Kit Components
AbutmentRemovalDriver• Usedtoremovefinalabutment;useafterremovingAbutmentScrew.
• Insertstraightintotheabutmentandrotateclockwise.• LongAbutmentRemovalDriverisfordisconnectinganabutmentwithacementedcrown.
DrillExtension• Extendsdrills&otherhandpiecetools.• No more than 35Ncm torque : Can be distorted
when too much force is applied.
Direction Indicator• Confirmsdrillingdirectionandlocationduringdrilling.• Checksdrillingposition.
PathFinder• Afterplacingafixture,aPathFindercanbeconnectedtoguideparallelforthenextimplant.• Gingivaldepthcanbemeasuredwiththegroovesespeciallyforflaplesssurgeries.
TorqueWrench&Adapter• TorqueWrenchhastorqueoptionsfrom15Ncmto45NcmandisusedfortheplacementofanimplantandfinaltighteningoftheAbutmentScrew.
(*)Separatesalesitem.
(*)Separatesalesitem.
L
TorqueWrench
TorqueWrenchAdapter
8 8
Ø2.8 Ø4.7
Ø2.0 Ø3.2
8 8
2 2
L
AnyRidge ® Surgical Kit » I. Surgical Kit
MegaGen Kit – 351350
Ratchet
OPTION Ø4 Ø5 Ø6 Ø7GUIDE PIN
Bone Profiler Kit
Hand Driver
AbutmentRemoval Driver
AnyRidge Solid Driver
Ball Driver
Transfer ImpressionCoping Driver
Octa Driver
AnyRidge Kit » Ⅲ. Prosthetics Kit
Ⅲ. AnyRidge Prosthetic KitA kit with all kinds of driver that are needed for prosthetics.
KANPK3000
Ref.C
RefertoPage.350
RefertoPage.349
RefertoPage.350
AnyRidge ® Surgical Kit » II. Prsthetics Kit
– 353352
*Handpiece Connector(Short) TBH250S
*Handpiece Connector(Long) TBH250L
*Ratchet Connector(Short) TBR250S
*Ratchet Connector(Long) TBR250L
Toque Driver(Short) TBT250S
*Toque Driver(Long) TBT250L
Type Ref.cHandpieceConnector
RachetConnector TorqueDriver
For Two piece impression Coping TCMID
For One piece impression Coping TCMIDE
Type Ref.C
Ø48.5 TANSDS400
13.5 *TANSDL400
Ø58.5 TANSDS500
13.5 *TANSDL500
Ø68.5 TANSDS600
13.5 *TANSDL600
Ø78.5 TANSDS700
13.5 *TANSDL700
Solid AbutmentProfile Diameter Length(mm) Ref.C
7 MOD300S
13 MOD300L
Length (mm) Ref.C
L
AnyRidge Kit » Ⅲ. Prosthetics Kit
➲ Prosthetic Kit Components
BallDriver• ForseatingoftheBallAbutmentintothefixture.• CanconnecttoaHandpiece,RatchetorTorqueWrench.• Availableinlongandshort.
ImpressionCopingDriver
• FortransfertypeofImpressionCoping.• Workswithfrictiononly.• Smallbutpowerfulgrip.
(Transfer)
Solid Driver• ForthedeliveryofSolidAbutments.• Colorcodedfordifferentprofilediameters.(Ø4-magenta,Ø5-blue,Ø6-yellow,Ø7-green)• Twodifferentheights.(8.5/13.5mm)• DirectlyconnectabletoTorqueWrench.
Octa Driver• ForseatingoftheOctaAbutmentintothefixture.• CanalsobeconnectedtoTorqueWrench.
(*)Separatesalesitem.
1.ConnectImpressionCopingandImpressionDrivertogether2.AdjustConnectionwithaFixturebyturningaHolderclockwise.3.PushtheHolderandputtheImpressionCopingintotheFixture.4.TurntheDriverclockwisetoensureconnectionoftheImpressionCopingandFixture.
1 2 3 4
(*)Separatesalesitem.
Option Option Option
L
AnyRidge ® Surgical Kit » I I. Prsthetics Kit
Regeneration – 551550
Handpiece Connector
option
Chisel Tip Chisel Handle
(TCMSC403)
(TANHCU) (TANHCS)
RatchetConnector(TANRES)
Ratchet Connector (TANREL)
Lance Drill (MGD100L)
BonEx Kit - - - KBECS3000
BonEx Kit component
Ø2.4
13 7 / 8.5 / 10 / 11.5
TCMBE2413
Ø2.8 TCMBE2813
Ø3.3 TCMBE3313
Ø3.8 TCMBE3813
Ø4.3 TCMBE4313
Ø4.8 TCMBE4813
Expander
Ⅱ. BonEx Kit™
Narrow Ridge » Ⅱ. BonEx Kit
Useful in very narrow bone (<2mm)Use Lance Drill before Expanders to avoid bone breakage during drilling.Can be tapped until the end with a Mallet.
Step-by-step ridge Expander can be placed with a Handpiece & a Ratchet Extension, matching with the core shape of the AnyRidge Fixture .
: Best combination with SmarThor™: Perfect for the exceptionally difficult cases
Description Diameter Length (mm)
Marking line(mm)
Ref.C
Product coordinator : Eui Jin Han, [email protected]
AnyRidge ® Surgical Kit » III. BonEx Kit
III.
MegaGen Kit – 353352
OPTION Ø4 Ø5 Ø6 Ø7GUIDE PIN
Bone Profiler Kit
3
OPTION
OPTION
BoneProfiler-GuidePin(TANPGF3305)included.
• Eachboneprofilercanbepurchasedseparatelyforrefill.
• Eachpakageincludesaboneprofilerandaguidepin.
Ø413
TANBPL40G
Ø5 TANBPL50G
Ø68
TANBPS60G
Ø7 TANBPS70G
Profile Diameter Length (mm) Ref.C Boneprofiler
Guidepin
AnyRidge Kit » Ⅳ. Bone Profiler Kit
Ⅳ. AnyRidge Bone Profiler KitRemoves the overhanged bone around a fixture to allow adequate seating of a Healing Abutment or a Prosthetic Abutment.•PlaceaGuidePinintoafixtureandchooseaBoneProfilerwhichfitswiththe
situation.•Fourdifferentsizesofboneprofilerandfourguidepinsareincludedinthekit.
KARBP3000
Ref.C
AnyRidge®
Rev.00
L
AnyRidge ® Surgical Kit » IV. Bone Profiler Kit
– 355354
4 Ultra-short
Hex 1.2
MDR120SS
10 Short MDR120S
15 Long MDR120L
20 Extra Long MDR120EL
- not included in the surgical kit- can be purchased separately and placed into the ‘option’ spaces provided in the surgical kit
Ⅴ. Optional components
AnyRidge Kit » Ⅴ. Optional components
RightAngleDriverTip• UsedforallCoverScrews,allabutmentscrews
and all Healing Abutments.• Hextipcanwithstand35-45Ncmoftorquewithoutdistorting.
Lindermann Drill• Crosscutonthedrill.• Cancorrectthepathduringdrilling. 2 TEEL200M
TypeLength(mm)
Diameter(mm)
Ref.C
Ref.C
L
Insert Driver• UsedforallCoverScrews,allabutmentscrewsandallHealingAbutments.
• Hextipcanwithstand35-45Ncmoftorquewithoutdistorting.
HandTap• Usefulwhentheinternalscrewofafixtureis
damaged.• Retappingdamagedthreads.• Needtobepatientandforce-controlled.
10 ShortHex 1.2
MID120S
15 Long MID120L
M1.8 THT180L
TypeLength(mm)
Type
Ref.C
Ref.C
L
Multi-unitDriver(2.0Hex)(ForMulti-unitAbutment)• Fortheseating&tighteningofmulti-unitAbutment(Straighttype)
10 Short TCMMUDS20
15 Long TCMMUDL20
Length(mm) Type Ref.C
L
2
Ø5.0 / Ø2.03.5
FD5020
Ø6.0 / Ø2.0 FD6020
Diameter Length (mm) Ref.C
FlatteningDrill• Inthecaseofirregularbone,stopperdrillcanbedrilledinprecisedepthbyflatteningthebone.
• FlatteningLanceandHousingareconnectedtogether.TwotypesofHousingdiameters(Ø5.0&Ø6.0)arecomposedinaccordancewiththesizeoffinaldrilldiameter.
• Ø5.0=StopperDrillØ2.0~Ø4.3 Ø6.0=StopperDrillØ4.8~Ø5.4
• Formationofboundarythroughhousingwillguidethenextdrillinglocationoffixture. Ø5.0Ø2.0 Ø6.0
FlatteningLance
FlatteningHousing
FlatteningDrill
AnyRidge ® Surgical Kit » V. Optional components
AnyRidge ® Surgical Kit » V. Optional components
MegaGen Kit – 355354
ReamerDrill&CenterPin• RemovesinnerlipofthecastaftercastingBurn-outCylindersofSolidAbutment.• CenterPinhave4differentdiametersaccordingtotheprofilediameterofSolidAbutments.
Ø10.0 Reamer Drill TANRD
Ø4.0
Center Pin
TANRDJ40
Ø5.0 TANRDJ50
Ø6.0 TANRDJ60
Ø7.0 TANRDJ70
Diameter Type Ref.C
TrephineBurStopper• ControlsthedepthoftrephinationwithaStopperplacedintotheTrephine.
• Especiallyusefulincaseswithlimitedavailabebonefromimportantanatomy.
Manual Inserter• SpeciallydesignedformanualplacementofAnyRidgefixture.• Especiallyusefulatimmediateimplantplacementonmaxillaryanterior.
• Thetiphassamestructurewiththehand-piececonnector.
7.0 TANTSF2307
8.5 TANTSF2308
10.0 TANTSF2310
11.5 TANTSF2311
Length (mm) Ref.C
TANMI
Ref.C
TrephineBurStopper
Connection
L 7 8.5 10
AnyRidge Kit » Ⅴ. Optional components
Type
BottomDrill• It removes remaining bone in osteotomy socket aftertrephinedrilling.• Itimprintsthesizesoffixtures,forexample7,8.5,10,11.5and13mm,bylasermarker.
Ø3.3
Short(32mm)
TCMBDS33
Ø3.8 TCMBDS38
Ø4.8 TCMBDS48
Ø5.8 TCMBDS58
Ø6.8 TCMBDS68
Ø3.3
Long(38mm)
TCMBDL33
Ø3.8 TCMBDL38
Ø4.8 TCMBDL48
Ø5.8 TCMBDL58
Ø6.8 TCMBDL68
Diameter Type Ref.C
D
7(7.5)
8.5(9)
10(10.5)
11.5(12)
13(13.5)
RatchetWrench• Usedtoexertmoreforcethanhandpiece.• Nobearingsystem:Nobreakageandcorrosionproblems.
• AttachestoRatchetExtension.• Arrowlasermarkingindicatesdirectionofforce.
MRW040S
Ref.C
Regeneration – 559558
Ⅰ. i-Gen
Augmentation » Ⅰ. i-Gen
4 9 11 4.5 - - A1 IG1W45094 10 11 5.5 - - A2 IG1W55104 11 11 6.5 - - A3 IG1W65115 9 11 4.5 - - B1 IG2W0918
6.5 11 11 5.5 - - B2 IG2W11209 13 11 6.5 - - B3 IG2W13235 9 11 4.5 6 4.25 C1 IG3W0921
6.5 11 11 5.5 8 4.25 C2 IG3W11259 13 11 6.5 10 9 C3 IG3W13288 11 11 5.5 9.6 9.25 D1 IG4W1128
i-Gen Membrane Dimension
PL(Proximal Length)
BW(Buccal width)
BL(Buccal Length)
BD(Buccal
Distance)
LW(Lingual width)
LL(Lingual Length)
A1
Small Regular Wide
B1
C1
A2
B2
C2
A3
B3
C3
Augmentation
Ref.CType
BW LW
BL
BDLL
PL
Product coordinator : Jung Ho Nam, [email protected]
Extra Option Products » I. i-Gen
– 561560
Augmentation » Ⅰ. i-Gen
➲ i-Gen Components
M 2.0• MegaGen (AnyOne, EZ Plus(R&W) & MegaFix)• Straumann (Standard & Standard Plus)• Nobel Biocare (Nobel Replace Tapered Groovy)• Dentium (Superline)• Dio (Steady, SM, IFI)• Neobiotech (IS)• Osstem (TS IV)
M 1.8• MegaGen (AnyRidge)• Dentsply-Frident (Ankylos C/X Implant)• Zimmer (TSV)
M 1.6• MegaGen (AnyRidge Octa 1, EZ Plus Internal _Small)• Straumann (Bone Level)• 3i (Osseotite certain & Full Osseotite NT Certain)
M 1.4• MegaGen (MiNi)
i-Gen Screw* We recommend that you verify the size of the abutment screws before use, it should be noted that it may not be fully compatible depending on the tolerance of each manufacturer.
C.H
C.H
C.H
C.H
Hex 1.2 1.0 ICS3510
i-Gen Cover Screw- Use Hand Driver(1.2 Hex)
• Used for primary closure after i-Gen(on top of i-Gen screw).
Type Height (mm) Ref.C
Flat Healing Abutment• Used for one stage approach after i-Gen
(on top of i-Gen screw).2 FHA402
3 FHA403
4 FHA404
Height(mm) Ref.C
H
Hand Driver (1.6 Hex)• This driver is designed to deliver i-Gen screw into
a fixture. Just finger force is enough to tighten the i-Gen screw.
10 Short TCMHDS1600
L
Length(mm) Type Ref.C
M1.8
1.0 IA1810
2.0 IA1820
3.0 IA1830
4.0 IA1840
5.0 IA1850
M2.0
1.0 IA2010
2.0 IA2020
3.0 IA2030
4.0 IA2040
5.0 IA2050
Type Cuff Height(mm) Ref.C
M1.6
1.0 IA1610
2.0 IA1620
3.0 IA1630
4.0 IA1640
5.0 IA1650
M1.4
1.5 IA1415
2.0 IA1420
3.0 IA1430
4.0 IA1440
5.0 IA1450
1.0
3.5
Extra Option Products » I. i-Gen
Instrument & Material – 589588 Instrument & Material – 589
Low stability Medium stability High stability
Full splint IL2-stage
Traditional
Implant at riskmonitor ISQ
Partial1-or 2-stage
Early
Single1-stage
Immediate
IndicationSurgical protocol
Restorative protocol
Implantplacement
Post sutureremoval
ProstheticsComplete
S-L-A RBM
1 2 3
Have you made the PARADIGM SHIFT yet?
Do it the AnyRidge Way
When is the right time to load?
AnyRidge is Perfect for Early(Immediate) loading with Mega-ISQComplete Prosthetic Process in Only 4 WeeksWith Con�dence! Objective Evidence with ISQ Values
Excellent Primary Stability with Knife thread
Excellent Secondary Stability with Xpeed
For smooth insertion and stronger primary stability.No cutting edge for minimum invasion. Perfect result in any bone condition.
For faster, stronger osseointegration. Surface technology incorporating Ca2+ ions on the SLA treated surface.100% acid-residue free surface
- Stable dispersion of stress with Buttress Thread shape- Easier Insertion with Sharp Thread shape- Increase the surface area of the round side compared with the straight side.
XPEED Surface Treatment presents much faster & stronger Osseointegration than RBM or S-L-A
Test result after 4Ws with rabbit
Using Mega-ISQ enable accurate and objective assessment of implant stability which, in conjunction makes leading to predictable outcomes.
Experience stable or increasing ISQ values continuously when using AnyRidge implants.
the AnyRidge Way
II. Mega-ISQ
Extra Option Products » II. mega-ISQ
– 599598
Ⅱ. Wireless Auto Torque Driver MEG-TORQ®
Instrument » Ⅱ. MEG-TORQ
MEG-TORQ2 Right Angle Driver included.
[1 Long Type, 1 Short Type(1.2 Hex)]MEG-TORQ
Right Angle Driver
Slot 0.5Short MDR050SLong MDR050L
Hex 0.9Ultra-Short MDR090SS
Short MDR090SLong MDR090L
Hex 1.2
Ultra-Short MDR120SSShort MDR120SLong MDR120L
Extra-Long MDR120EL
Hex 1.25Short MDR125SLong MDR125L
Hex 1.6Short MDR160SLong MDR160L
Hex 3.0 Ultra-Short RDI30U
Description Ref.C
Operating button (A)
Operating button (B)
On/Off , Torque selection
Clockwise / Counterclockwise
RPM selection
LCD Panel RPM
Rotation information
Battery Condition
Calibration mode
Torque information60
rpm
➲ Use as Second Implant Motor at soft bone cases (Max torque 35Ncm)
➲ Quick removal of numerous prosthetic appliances➲ Easy to reach to molar areas➲ Approach the implants placed in distal areas➲ Record the number of abutment screw torquing accurately
Accurate Torque Value, Strong Power!
Product coordinator : Jerry Park, [email protected]
Combined world’s first class FAULHABER motor from Germany and Swiss-made reduction gear.
I
Extra Option Products » III. Meg-Torq
– 395394
4
M1.4Magenta
M1.6Blue
M1.8Yellow
M2.0Red
M2.5Green
6 8 0 5
Hex
4
M1.4Magenta
M1.6Blue
M1.8Yellow
M2.0Red
M2.5Green
6 8 0 5
➲ 911 Fixture Removalkit
The total solution kit to remove broken pieces easily when fixture, abutment or screw are fractured. KPSCS3000
KPSFS3000
Ref.C
Ref.C
911 kit
911 Kit
This is a simplified version of 911 kit, only to use for fixture removal.
Product coordinator : jung hee Lee, [email protected]
IV. 911 Kit
Extra Option Products » IV. 911 Kit
MegaGen Kit – 395394
FixtureRemover• Toremovethefixture.WhenselectingaFixtureRe-mover,considertheouterdiameterofaFixture.IncaseofAnyRidgeFixturethatthethreadisformedunderplatform,selectaFixtureRemoveraccordingtoplatformsize
TorxDriver• Toconnectfixtureremovalscrewtoafixture.
TorqueWrench• TW500:Tochecktorqueforcewhenremovingfixture.
• TW70:TochecktorqueforcewhentighteningFixtureRemoverScrew.
FixtureRemoverScrew• ToconnectfixtureandFixtureRemover.• Recommendedtighteningtorque -FSS14,FSS16:40~50Ncm -FSS18,FSS20,FSS25:70~80Ncm.
Ø3.0~Ø3.615 *FSS3035
20 *FSL3035
Ø3.7~Ø4.615 FSS3540
20 FSL3540
Ø4.7~Ø5.615 FSS4555
20 FSL4555
Ø5.7~Ø7.015 *FSS6080
20 *FSL6080
Applied Fixture Diameter Length(mm) Ref.C
5 TD05
15 TD15
20 *TD20
300Ncm TW500
70Ncm *TW70
Length (mm) Ref.C
Type Ref.C
L
L
➲ 911 kit Components (Continued)
911 Kit
(*)Separatesalesitem.
(*)Separatesalesitem.
(*)Separatesalesitem.
(*)Separatesalesitem.
4 6 8 0 5M1.4 (MiNi) Magenta
40~50 Ncm
*FSS14
M1.6 (EZ Plus, ExFeel Ø3.3,Octa 1) Blue FSS16
M1.8 (AnyRidge) Yellow
70~80 Ncm
FSS18
M2.0(AnyOne, MegaFix, EZ Plus, ExFeel)
Red FSS20
M2.5 (Rescue) Green *FSS25
Applied Fixture Thread
Ref.CTorqueColor
Extra Option Products » IV. 911 Kit
– 397396
AbutmentRemover• Toremovefracturedabutment.• UsescrewsizeM1.8&M2.0.
ScrewRemover• Toremovefracturedscrew.• Screwsizeofsystem M1.4=MiNi�
M1.6=EZ�Plus,�Exfeel�Ø3.3
M1.8=AnyRidge�
M2.0=AnyOne
ScrewRemoverGuide• TosecuretheScrewRemoverfrommovingsidetosidewhenremovingthescrew.
22 ASS
27 ASL
30M1.4 & M1.6
*SS1416S
45 *SS1416L
30M1.8 & M2.0
SSS
45 SSL
Length (mm) Ref.C
ScrewRemoverGuideHolder• TooltosupporttheScrewRemoverGuide.
SSGH
Ref.C
HexRemover• Toremovehex-damagedAbutmentScrew,CoverScreworHealingAbutment.
22 HSS
27 HSL
Length (mm) Ref.C
L
L
L
911 Kit
➲ 911kit Components
Length (mm) Type Ref.C
(*)Separatesalesitem.
(*)Separatesalesitem.
Internal
10∘(AnyRidge) SSIG10
16∘(AnyOne OneStage) SSIG16
22∘(AnyOne Internal / MiNi Internal) *SSIG22S
22∘(AnyOne Internal / MiNi Internal) SSIG22
22∘(AnyOne Internal / MiNi Internal) *SSIG22W
External
HEX 2.4(AnyOne External Ø3.5) SSEG24
Hex 2.7(AnyOne External) SSEG27
Hex 3.3(Rescue External) SSEG33
Applied Fixture Diameter Type Ref.C
Extra Option Products » IV. 911 Kit
MegaGen Kit – 397396
911 Kit
GrindingandRemovalBurwithaImplantmotor ARARHB18
ARARS
Ref.C
Ref.C
➲ Broken Abutment Remover Set for AnyRidge
Components HighSpeedBur+AbutmentRemoverDriver+AbutmentRemoverHousing
How togrindremainingfracturedabutmentusingahigh-speedbur,andremovetheresidueusingahousing-connecteddriver
Recommendations 1.Ifanabutmenthexisnotseparatedeventhoughtheabutmentisremoveduptothestopper, remove theabutmenthexwithpincette.2.Checkthebladebeforeusage.Itishighlyrecommendedtouseanewburifitiswornout.3.Washandsterilizeimmediatelyaftereveryusage
※Cautions 1. Perpendicularly insert a high-speed bur into a fixture 2. Do not overload when using a high-speed bur. Adequate irrigation is highly recommend when using. 3. The given kit case is for storage only. Do not sterilize. 4. Anti-clockwise when in use.
: Remover set to remove fractured AnyRidge Abutment
Extra Option Products » IV. 911 Kit
Fig 1. This 52 year-old male patient lost his maxillary left first molar due to periodontitis during implant treatment for other teeth. The panoramic radiograph was taken about one month after extraction, and a large extraction socket defect was expected. On the clinical examination, the inter-arch space for future crowns was very limiteddue to large tuberosity, so it was planned to remove bone and soft tissue from this sites (red line on panoramic view). The remaining vertical height was about 7~8 mm under the sinus floor.
Fig 2. Two parallel incision lines were made on the crest expecting the soft tissue amount after reducing the crestaldimension. There was no buccal plate remain-ing on the extraction socket of the first molar area.
Fig 3. During the procedure to make an ideal shape of alveolar ridge, all thecortical bone was removed from the crest.
Fig 4. Now the ridge has normal shape and inter-arch distance was recovered enough to make ideal contour of crowns. However, the bone density was extremely soft with-out any cortical bone. It was much less than Type IV bone density. At the case of like this, how long do we have to wait after implant placement to start the prosthetic procedures? Normally we wait for at least 6 months for Type IV bone with conventional implant system because we cannot get enough initial stability due to less bone density. However if we can make excellent initial stability with mandibular implants by changing implant design, we may start prosthetic procedures after 3 months or less. That is one of important design con-cepts on AnyRidge implant system.
Fig 1
Fig 3
Fig 2
Clinical Case 1 - Courtesy of Dr. Kwang-Bum Park
AnyRidge Clinical Case
AnyRidge implant can make excellent initial stability even at this extremely loose bone.
Clinical Cases
Clinical Cases
Fig 5. Two osteotomy sockets were pre-pared with a single trial of drilling using a trephine (4050 which has 5.0mm outer diameter). Bone density was extremelysoft as expected, and there was enough ridge width both to buccal and lingual side. If we place fixtures with conventional thread design, satisfactory initial stability is really difficult to achieve due to loose bone density. AnyRidge implant was designed to have same core diameter, but different thread depth with increase of fixture diam-eter. So in the case like this,we needed to consider the bone density ur-ing socket preparation to choose adequate depth of thread which could affect initial stability.
Fig 6. Two 7.0(W)x8.5(L)mm AnyRidge fixtures were placed with excellent initial stability because of deep and knife threads. Compared with the size of osteotomy sockets, the fixtures were 2mm bigger in di-ameter, but the core diameter of these wide fixtures are only 4.8mm. The whole depth of thread could be used to engage bone to get more BIC and better initial stability.
Fig 7. The bone defect was grafted with au-togenous bone which was harvested during reshaping of alveolar ridge and trephina-tion. And primary closure was made to make sure bone regeneration.Fig 8. The panoramic view after surgery.
Fig 9. Three months after implant place-ment, the second stage surgery was made and provisional restoration was delivered two weeks later. The final restoration was delivered about one monthlater for the maturation of regenerated bone. On the radiograph taken 2.5 years later, the crestal bone regenerated up to the level of platform.
Fig 4
Fig 5 Fig 6
Fig 8
Fig 9
Fig 7
Clinical Cases
Fig 1. This patient was 56 years old male patient and had a chief complaint of chewing difficulty on the left first mandibular molar due to periodontitis. On the panoramic radiograph, the tooth was floated with complete bone loss to the apex, and there was not enough bone to get initial stability for implant placement at the apex above mandibular nerve. So I decided to extract the tooth and wait for 4 months for regeneration of the socket.
Fig 2. The patient came back to my office af-ter 4 months. Healing appeared good enough clinically, but the panoramic view still showed large socket defect. In many cases like this, we can expect some amount of bone fill in the socket which can allow minimal initial stability for implant placement.
Fig 3. When the flap was opened, I was very embarrassed that bone regeneration did not occur in the socket. None of remaining bone could be used for implant fixation.
Fig 4. A widest AnyRidge implant 8.0mm was placed on the mesial wall of extraction socket, but there was no initial stability. This trial was quite heroic treatment, but there was no other option except this be-cause he flied many hours for this surgery.
Fig 5. The mixture of Allograft (Mega-Oss) and Synthetic bone (Bone Plus) was placed into the remaining socket defect and a collagen membrane was covered. Then primary closure was made with releasing incision on the periosteum.
Clinical Case 2 - Courtesy of Dr. Kwang-Bum Park
Fig 1
Fig 2
Fig 3
Fig 4
Fig 5
AnyRidge implant has excellent surface treatment which can be osseointegrated at this extreme case of bone defect.
Clinical Cases
Fig 6. On the panoramic view after surgery, we could find that none of the fixture was engaged with remaining bone, so it had more than 1.6mm gap from the tip to the depth of knife threads. I worried about the bone filling and success of the osseointe-gration on this fixture.
Fig 7. However, I was surprised with the hard cortical bone regeneration over the cover screw when I did the second stage surgery with the Biolaser.
Fig 8. On the intraoral radiograph taken several weeks after second surgery, we could see the fully regenerated bone into the bottom of thread depth.
Fig 9. The patient came back to our office to get one more implant on the maxillary upper molar after 2 years from the first implant surgery. The regenerated bone was matured and showed very stable crestal bone on the intraoral radiograph.
Fig 6
Fig 7
Fig 8
Fig 9
MegaGen History
201201.02 Present a new slogan for coming decade. "To be One, To the world, To the Future".01.17 MegaGen implant’s AnyRidge system was awarded 2012 Jang Young Sil prize12.25 MEGAGEN TOWER opened
201012.14 President Park, Kwang Bum was awarded grand prize for “2010 Intellectual property management”
200805.29 Won the reward prize of the man of merit on the First Day of Medical Appliances (Minister's Prize of the Ministry for Health and Welfare)10.22 Awarded the Prime Minister's citation at "The Best Venture Enterprise 2008"12.02 Awarded "a five million dollar export tower prize" on the Forty Fifth Day of Trade
200201.03 Established MegaGen Co., Ltd. (CEO Kwang-Bum Park)
200603.08 CE Certification for the ExFeel Implant System/Intermezzo Implant System06.09 Selected as the Inno-Biz (No. 6535-0617)09.11 Licensed to establish an organ bank (Korea Food & Drug Administration: No. 88)
200407.14 Government Industry Auxiliary Research Institute certified (ID No.20041761/ MegaGen Corp)09.09 ISO9001/2000 (NO.12 100 23436 TMS)
201404.01 MEG-Inject, Red Dot award 2014 Winner09.28 MegaGen Meg-Series won Convergence Federation Prime Minister’s Award for small and medium-sized business
200309.01 Performed a project related to TBI business (Ministry of Commerce, Industry and Energy)
201103.16 [Award] Recived a Ministry of Knowledge & Economics award on "2011 Chamber's day"05.19 [Award] Received a Prime Ministry Award on The 46th INVENTION DAY of Korea.12.21 MegaGen implant was awarded U$10 million export tower on the Trade Day
200702.22 KGMP04.11 SFDA in China Certification for the EZ Plus Implant
System & the Rescue Implant System
200509.02 U.S. FDA approval for the Intermezzo Implant System NO.K05101812.21 Certification of ISO9001/13485 DNV (NO.2005-OSL-AQ-0376)
201303.18 AnyRidge got approval from Russia
201703.27 Selected as Global IP Star Company (Regional Intellectual Property Center)05.31 Selected as Excellent Venture Company (Venture Business Association)10.14 Certified TRUST QUALITY (CLEAN IMPLANT FOUNDATION)12.13 Awarded a grand prize for Export Innovation Enterprise (Korea Trande-Investment Promotion Agency, "KOTRA")12.14 Awarded the prize of $50 million Export Tower (Korea International Trade Association)
200906.30 Appointed as a leading company for future Bio-technology dental implant development from Korean government09.02 Prime Minister of Korea Award of “Innovate Technology 2009”
201604.01 Nominated as KISTI family company from Korea Institute of Science
and Technology Information04.27 Nominated as Youth friendly Smallgiants from Ministry of Employment
and Labor06.30 Nominated as the top leading venture company (global & continuous
growth) from Korean Venture Business Association09.28 Awarded as an outperforming company in Global Standard Policy Forum09.29 National Productivity Competition Prime Minister Awarder10.19 Ranked as one of the most valuable companies from Asian Science
Park Association12.05 Receive 30 million dollars export award
201801.01 Selected as 'Young man friendly leading company' (Ministry of Employment and Labor)05.23 Certified as 'Technology Innovation Company' by INNOBIZ06.24 Selected as the Best Company in Job creation07.01 Selected as Excellent Venture Company (Job creation, Global, R&D)07.10 Selected as Employment-friendly Company11.21 Selected as Daegu Star company 100 (Daegu)12.13 Awarded a Citation (Korea Technology Finance Corporation) by INNOBIZ12.19 Awarded an appreciation plaque for exports meritorious company
(Dalseoung district)
201503.18 Received a commendation from Korea International Trade Association (42nd Commerce Day)06.26 Venture company certification (Korea Technology Finance Corporation)07.01 Selected as World Class 300 Company (Small and Medium Business Administration) Selected as Global Company (Ministry of Trade, Industry and Energy)11.27 Received a Creative Economic Award (2nd Daegu, Gyeong-buk, Creative Economic Award Competition) Gyeong-buk office12.07 Received 20 million dollars export award 12.16 Received a Minister award from Ministry of Trade, Industry and
Energy (15th Daegu, Gyeong-buk, high-technology venture company)12.17 Awarded from a chairman of Korea technology finance corporation
(Inno Business Association)12.22 Ranked as one of the most valuable companies for inventing Jobs
from Korean Intellectual Property Office
www.megagen.com.au
08 8331 [email protected]
www.megagen.com.au1-233 Greenhill Rd. DULWICH SA 5065