West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large...
-
Upload
oliver-wheeler -
Category
Documents
-
view
213 -
download
1
Transcript of West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large...
![Page 1: West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large diameter by Nikhef team.](https://reader036.fdocuments.us/reader036/viewer/2022083008/56649ef45503460f94c07e08/html5/thumbnails/1.jpg)
West input
Rotated DN1000 standard valve
Options: - small or large link - small link: small or large diameter
by Nikhef team
![Page 2: West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large diameter by Nikhef team.](https://reader036.fdocuments.us/reader036/viewer/2022083008/56649ef45503460f94c07e08/html5/thumbnails/2.jpg)
West input
New valve position
Valve DN630
Adapter 700 for end stations by Nikhef team
![Page 3: West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large diameter by Nikhef team.](https://reader036.fdocuments.us/reader036/viewer/2022083008/56649ef45503460f94c07e08/html5/thumbnails/3.jpg)
West / North end
Mi
Mirror
Mi
2370
Cold surface: length: 2370 mm diameter: 1000 mm
Baffles: diameter: 620 mm 3 needed to cover cold surface temperature influences mirror temperature material: glass?
![Page 4: West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large diameter by Nikhef team.](https://reader036.fdocuments.us/reader036/viewer/2022083008/56649ef45503460f94c07e08/html5/thumbnails/4.jpg)
Side view
Reinforcement ribsL = 3490 mmD = 1208 mm
by Nikhef team
![Page 5: West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large diameter by Nikhef team.](https://reader036.fdocuments.us/reader036/viewer/2022083008/56649ef45503460f94c07e08/html5/thumbnails/5.jpg)
Cryo link details
Heat bridge/expansion bellows
LN2 vessel support
LN2 (250 l)
superinsulation
BaffleD= 620 mm
PumpoutFlange (100 mm)
3.2 mm/m
![Page 6: West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large diameter by Nikhef team.](https://reader036.fdocuments.us/reader036/viewer/2022083008/56649ef45503460f94c07e08/html5/thumbnails/6.jpg)
Transfer line connections
LN2 inlet duct
34 mm
60 mm
LN2 max level (control ± 10 mm)Bath width: 325 mm
Rapid heatup
![Page 7: West input Rotated DN1000 standard valve Options: - small or large link - small link: small or large diameter by Nikhef team.](https://reader036.fdocuments.us/reader036/viewer/2022083008/56649ef45503460f94c07e08/html5/thumbnails/7.jpg)
Phase separator
2 m above cryo link