Welkom bij het Webinar Industrial Automation - siemens.be · Engineering options E.g. TIA Portal...
Transcript of Welkom bij het Webinar Industrial Automation - siemens.be · Engineering options E.g. TIA Portal...
Welkom bij het WebinarIndustrial Automation
We starten om 10u00. Voor een vlot verloop van dit webinar, gelieve uw microfoon uit te schakelen.Dit webinar wordt opgenomen
Unrestricted / © Siemens NV 2017.Page 2
Agenda
1. Hoever staan we met de TIA portal?
2. Welke PLC's zijn beschikbaar?
3. Hoe ziet de toekomst eruit?
4. Migratiethema's,…
Unrestricted / © Siemens NV 2017.Page 3
Agenda
1. Hoever staan we met de TIA portal?
2. Welke PLC's zijn beschikbaar?
3. Hoe ziet de toekomst eruit?
4. Migratiethema's,…
Unrestricted / © Siemens NV 2017.Page 4
Totally Integrated Automation PortalOne Engineering Framework for all Automation Challenges
WinCC V15
SIMATIC HMI
Startdrive V15
SINAMICS
STEP 7 V15
SIMATIC PLC
Safety V15
Safety
Totally Integrated AutomationPortal
One common Engineering Framework for the Production-Automation
V15,22/12/2017
Unrestricted / © Siemens NV 2017.Page 5
Basic licenses –Overview of the software performance range
Communication PROFIBUS, PROFINET, AS-i, IO-Link, ET 200, network topologyPROFIsafe via PROFIBUS and PROFINET
Common functions E.g. System diagnostics, import/export to Excel, Undo, …
Engineering options E.g. TIA Portal Multiuser, SIMATIC Energy Suite, SIMATIC ProDiag…
SIMATIC STEP 7 V14/ STEP 7 Safety V14 SIMATIC WinCC V14
Programming languages (F-)KOP, (F-)FUP, SCL, AWL1), S7-GRAPH1) Machine-level operator control and monitoring and process visualization (SCADA)
S7-1500/SW-Controller (F)
S7-1200 (F)
S7-1500 (F)
S7-300/400/WinAC (F)B
asic
Single station PC
Basic Panelsand 2nd Generation
Comfort Panelsand Mobile
(without Micro)
SCADA
Adva
nced
Com
fort
Bas
ic
Prof
essi
onal
Bas
ic
Prof
essi
onal
Adva
nced
1) S7-300/400/1500/WinAC
Unrestricted / © Siemens NV 2017.Page 6
System functionsWin10-Support for TIA Portal
Supported operating systems
V13 SP2V14 SP1
V15
01/2020Windows 7
10/2025Windows 10
End of ext.support:
Use case
§ Long-term Microsoft Windows support with Windows 10
§ One shared operating system platform for TIA Portal and"Classic* products"
§ Project upgrade to a single-station computer :Vxxà V13 SP2à V14 SP1 /V15
Customer benefits*
Windows 7 (64-bit)
Windows 7 Home Premium SP1 *
Windows 7 Professional SP1
Windows 7 Enterprise SP1
Windows 7 Ultimate SP1
Windows 10 (64-bit)
Windows 10 Home Version 1703 *
Windows 10 Professional Version 1703
Windows 10 Enterprise Version 1703
Windows 10 Enterprise 2016 LTSB
Windows 10 IoT Enterprise 2015 LTSB
Windows 10 IoT Enterprise 2016 LTSB
Windows Server (64-bit)
Windows Server 2012 R2 StdE (full installation)
Windows Server 2016 Standard (full Installation)
*for Basic edition only
Unrestricted / © Siemens NV 2017.Page 7
TIA Portal Products and actual products compatibility
WinCC flexible 2008 SP2 onwards
STEP 7 V5.4 SP5 onwards
TIA Portal based software:
V11, V12, V13, V14, V15 ...
Installation of different software products on a single computer
Unrestricted / © Siemens NV 2017.Page 8
Available Devices in TIA PortalOverview
Controller• Modular Controller SIMATIC S7
• S7-1500• S7-1200• S7-300• S7-400
SIMATIC PC-based Controller• SIMATIC S7-modular EC (F)• SIMATIC WinAC RTX (F)• SIMATIC WinAC MP
All modules that are still actively marketed as of 01.10.2007
Distributed I/O§ ET 200S§ ET 200M§ ET 200L§ ET 200iSP§ ET 200pro§ ET 200eco PN§ ET 200eco§ ET 200R§ ET 200SP§ ET 200MP
Industrial Communication
§ PROFIBUS§ PROFINET§ Gateways§ AS-Interface
SIMATIC HMI§ Panel§ SCADA
SINAMICS Drives§ G120§ Others via GSD(ML)
Unrestricted / © Siemens NV 2017.Page 10
Agenda
1. Hoever staan we met de TIA portal?
2. Welke PLC's zijn beschikbaar?
3. Hoe ziet de toekomst eruit?
4. Migratiethema's,…
Unrestricted / © Siemens NV 2017.Page 11
SIMATIC S7-1500Positioning modular controller
App
licat
ions
com
plex
ity
CapabilityI/O capacity, program size, instruction time, communication skills, …
The modular compact controllerfor solutions in the compact /basic area of automation
SIMATIC S7-1200
The modular controller forsystem solutions in the middleto high-end range automation *)
SIMATIC S7-400
Logic modules for switching andmonitoring for low-endapplications automation
LOGO!
„TIA“applications
„Stand
alone“applications
Bas
icSt
anda
rd
(modular)compact
controller
(modular)controller
logic modules
Product CharacterizationApplication
Nan
o
Segment
SIMATIC S7-300
Adv
ance
d
Unrestricted / © Siemens NV 2017.Page 12
SIMATIC New Controller GenerationController scalability that meets all requirements
S7-1500: Advanced Control§ Balance of control for machines or plants§ Complex automation architectures that require Many HMI’s, Drives and
other field devices§ Customized mass production control§ Perfect for when machine to machine controls
are required for an entire production process
Application Requirements
Perf
orm
ance
S7-1200: Basic Control§ Perfect for stand-alone simple machine control§ Material handling & packaging§ Vertical form, fill and seal
Unrestricted / © Siemens NV 2017.Page 13
Advanced ControllerSIMATIC S7-1500 Software Controller
SIMATIC S7-1500
SIMATIC New Controller GenerationAlways the appropriate Controller performance with comprehensive functionalities!
Syst
empe
rfor
man
ce
Application complexity
Distributed ControllerSIMATIC ET 200SP CPU
Basic ControllerSIMATIC S7-1200
Engineered with TIA Portal
Unrestricted / © Siemens NV 2017.Page 15
Connection resources
Integrated Analog I/O
SIMATIC Basic Controller portfolio
High-Speed Counter
Integrated Digital I/O
PROFINET Ports
Bit performance
Work memory /int. load memory
CPU type 1212FC
85 ns
100kB2 MB
8/6
6
2/-
38
1214C
85 ns
100kB4 MB
14/10
6
2/-
38
1211C
50 kB1 MB
6/4
6
85 ns
2/-
38
1215FC
85 ns
150 kB4 MB
14/10
6
2/2
38
1217C
85 ns
150 kB4 MB
14/10
6
2/2
38
1215C
85 ns
125 kB4 MB
14/10
6
2/2
38
1214FC
85 ns
125kB4 MB
14/10
6
2/-
38
1212C
85 ns
75kB2 MB
8/6
6
2/-
38
SIMATIC S7-1200 CPU
Unrestricted / © Siemens NV 2017.Page 16
Compact CPUs Standard-CPUs Technology CPUs MFP
CPUtypes
1511C-1PN
1512C-1PN
1511F-1PN
1513F-1PN
1515F-2PN
1516F-3PN/DP
1517F-3PN/DP
1518F-4PN/DP
1511TF-1PN
1515TF-2PN
1516TF-3PN/DP
1517TF-3PN/DP
1518F-4PN/DP
MFP
Interfaces
Program/data storage
175 KB1 MB
250 KB1 MB
150/225 KB
1 MB
300/450 KB1.5 MB
500/750 KB
3 MB
1/1.5 MB
5 MB
2/3 MB8 MB
4/6 MB20 MB
225/225 KB
1 MB
750/750 KB
3 MB
1.5/1.5 MB
5 MB
3/3 MB8 MB
4/6 MB20 MB
50 MB1
Bit-performance
60 ns 48 ns 60 ns 40 ns 30 ns 10 ns 2 ns 1 ns 60 ns 30 ns 10 ns 2 ns 1 ns
Max. numberof connections
96 128 96 128 192 256 320 384 96 192 256 320 384
Positioning axes• Typical2• Maximum2 5
105
105
105
107
307
3070
128128128
510
730
6580
70128
128128
Width 85 mm 110 mm 35 mm 35 mm 70 mm 70 mm 175 mm 175 mm 35 mm 70 mm 175 mm 175 mm 175 mm
New New
Hardware Configuration – Overview of SIMATIC S7-1500 –The right CPU for every application
1 Additional 50 MB memory for ODK applications; 2 For 4ms Servo/IPO cycle
11
11
11
11
11
2 11
2 11
2 11
23
11
11
2 11
2 11
2 11
23
Unrestricted / © Siemens NV 2017.Page 17
SIMATIC Distributed Controller portfolio
PROFIBUSPROFINET / IE
Interfaces
Width
Bit instruction time
Program /Data memory
CPU type
ET 200SP CPUs for low and middle range application
1512SP F-1PN*
100 mm
300 KB1 MB
S7-1512SP F
48 ns
1
1
1
1512SP -1PN
100 mm
200 KB1 MB
S7-1512SP
48 ns
1
1
1
1510SP F-1PN*
100 mm
150 KB750 KB
S7-1510SP F
72 ns
1
1
1
1510SP -1PN
100 mm
100 KB750 KB
S7-1510SP
72 ns
1
1
1
35 mm
125 DPSlaves
CM DP
DP-Master / DP-Slave
Unrestricted / © Siemens NV 2017.Page 19
Agenda
1. Hoever staan we met de TIA portal?
2. Welke PLC's zijn beschikbaar?
3. Hoe ziet de toekomst eruit?
4. Migratiethema's,…
Unrestricted / © Siemens NV 2017.Page 20
TIA Portal V15There is even more …
• Installation: Package, Classic
• Multiuser: Automatic selection, working
locally and server improvements
• Shared commissioning:
Download/upload of tag tables
• PLCSIM: Simulation of blocks with know-
how protection for S7-1500
• Recipes with S7-1500 in ASCII format
• Security: Configuration of Scalance M/S,
UMAC integration
• Openness: SCL export, PLC download,
Startdrive supported
• PLCSIM Advanced: Interrupts, events,
process image partitions, FW1.8 to 2.5
• SiVArc: Interrupt generation, template
screens, trend view control
•
• ProDiag: Improvements and quantity limit
increase
• OPC UA: Client, methods, companion
specifications
• Energy Suite: new instruction “energy
efficiency of maschines”, change of
powertag count within WinCC RT Prof.
• User Management Component:
Plant-wide user management
IntegratedEngineering
DigitalWorkflow
TransparentOperation
Unrestricted / © Siemens NV 2017.Page 21
SIMATIC S7-1500Positioning modular controller
App
licat
ions
com
plex
ity
CapabilityI/O capacity, program size, instruction time, communication skills, …
The modular compact controllerfor solutions in the compact /basic area of automation
SIMATIC S7-1200
The modular controller forsystem solutions in the middleto high-end range automation *)
SIMATIC S7-400
Logic modules for switching andmonitoring for low-endapplications automation
LOGO!
„TIA“applications
„Stand
alone“applications
Bas
icSt
anda
rd
(modular)compact
controller
(modular)controller
logic modules
Product CharacterizationApplication
Nan
o
Segment
SIMATIC S7-300
Adv
ance
d
Phase-out 1stof october
2013
Unrestricted / © Siemens NV 2017.Page 22
SIMATIC S7-1500Positioning modular controller
App
licat
ions
com
plex
ity
CapabilityI/O capacity, program size, instruction time, communication skills, …
The modular compact controllerfor solutions in the compact /basic area of automation
SIMATIC S7-1200
The modular controller forsystem solutions in the middleto high-end range automation *)
SIMATIC S7-400
Logic modules for switching andmonitoring for low-endapplications automation
LOGO!
„TIA“applications
„Stand
alone“applications
Bas
icSt
anda
rd
(modular)compact
controller
(modular)controller
logic modules
Product CharacterizationApplication
Nan
o
Segment
SIMATIC S7-300
Adv
ance
d
Phase-outplanned asfrom:1st of
october 2023
Unrestricted / © Siemens NV 2017.Page 23
Phase Out ET 200SMigration-strategy ET 200Sà ET 200SP
Phase-outplanned:1stof october
2019
Unrestricted / © Siemens NV 2017.Page 24
SIMATIC S7-1500Positioning modular controller
App
licat
ions
com
plex
ity
CapabilityI/O capacity, program size, instruction time, communication skills, …
The modular compact controllerfor solutions in the compact /basic area of automation
SIMATIC S7-1200
The modular controller forsystem solutions in the middleto high-end range automation *)
SIMATIC S7-400
Logic modules for switching andmonitoring for low-endapplications automation
LOGO!
„TIA“applications
„Stand
alone“applications
Bas
icSt
anda
rd
(modular)compact
controller
(modular)controller
logic modules
Product CharacterizationApplication
Nan
o
Segment
SIMATIC S7-300
Adv
ance
d
Unrestricted / © Siemens NV 2017.Page 26
Agenda
1. Hoever staan we met de TIA portal?
2. Welke PLC's zijn beschikbaar en op welke manier een keuzemaken?
3. Hoe ziet de toekomst eruit?
4. Migratiethema's,…
Unrestricted / © Siemens NV 2017.Page 27
Which kinds of migration exist?
Partial modernization§ Exchange of devices based on:
§ End of product lifecycles§ Increase in productivity with new devices
Advantage: investment protection, minimal effortDisadvantage: if so, two systems
System extension§ Extension of an existing plant
Advantage: investment protectionDisadvantage: two systems
Complete conversion§ Exchange of hardware, migration of software
Advantage : innovative products, advantages ofthe new system will be completely usedDisadvantage: considerable effort
Exis
ting
solu
tion
Mig
ratio
nen
gine
erin
g
Unrestricted / © Siemens NV 2017.Page 28
SIMATIC S7-1200Positioning modular controller
App
licat
ions
com
plex
ity
CapabilityI/O capacity, program size, instruction time, communication skills, …
The modular compact controllerfor solutions in the compact /basic area of automation
SIMATIC S7-1200
The modular controller forsystem solutions in the middleto high-end range automation *)
SIMATIC S7-400
Logic modules for switching andmonitoring for low-endapplications automation
LOGO!
„TIA“applications
„Stand
alone“applications
Bas
icSt
anda
rd
(modular)compact
controller
(modular)controller
logic modules
Product CharacterizationApplication
Nan
o
Segment
SIMATIC S7-300
Adv
ance
d
Phase-out 1stof october
2013
Unrestricted / © Siemens NV 2017.Page 29
Siemens Controller Family Release Overview
CPU221
CPU222
CPU224
CPU224XP
CPU226
Every CPU had two variants: 24V or 120-240V AC.224XPsi: with current sinking outputs
Unrestricted / © Siemens NV 2017.Page 30
Design and handling S7-200Set-up and extension options - maximum
S7-221 è S7-1211S7-222 è S7-1212S7-224 è S7-1214S7-224 XPè S7-1214S7-226 è S7-1215
Unrestricted / © Siemens NV 2017.Page 31
SIMATIC S7-1500Positioning modular controller
App
licat
ions
com
plex
ity
CapabilityI/O capacity, program size, instruction time, communication skills, …
The modular compact controllerfor solutions in the compact /basic area of automation
SIMATIC S7-1200
The modular controller forsystem solutions in the middleto high-end range automation *)
SIMATIC S7-400
Logic modules for switching andmonitoring for low-endapplications automation
LOGO!
„TIA“applications
„Stand
alone“applications
Bas
icSt
anda
rd
(modular)compact
controller
(modular)controller
logic modules
Product CharacterizationApplication
Nan
o
Segment
SIMATIC S7-300
Adv
ance
d
Phase-outplanned asfrom:1st of
october 2023
Unrestricted / © Siemens NV 2017.Page 32
TIA-selection ToolMigration-strategy
Need some help withthe migration?
Unrestricted / © Siemens NV 2017.Page 33
Interfaces
Retain memory:
Bit-Performance
Program /Data memory
CPU Type
SIMATIC InnovationMigration to SIMATIC S7-1500 CPU 1515(F)-2 PN
S7-1500
315-2PN/DP
50 ns
384 KB
412-1
75 ns
256 KB256 KB
412-2
75 ns
512 KB512 KB
412-2PN
31.25 ns
512 KB512 KB
1515-2PN
30 ns
500 KB3 MB
1 2
315F-2PN/DP
50 ns
512 KB
1515F-2PN
30 ns
750 KB3 MB
2
1
PROFIBUS
PROFINET / IE
PROFIBUS/MPI
MPI
IF Module
S7-300 S7-400
1
1
FlagsCountersTimersDB
4Kb2048204864Kb
4Kb2048204864Kb
4Kb2048204864Kb
2Kb256256128Kb
2Kb256256128Kb
512Kb 512Kb
1
2
3
Unrestricted / © Siemens NV 2017.Page 35
Retain memory:
SIMATIC InnovationMigration to SIMATIC S7-1500 CPU 1511(F)-1 PN
Interfaces
Bit-Performance
Program /Data memory
CPU Type 1511-1 PN
128 Kb
60 ns
150 KB1 MB
1
1
S7-1500
1511F-1PN
1
1
225 KB1 MB
128 Kb
60 ns
PROFIBUS
PROFINET / IE
PROFIBUS/MPI
MPI
IF Module
S7-300
FlagsCountersTimersDB
315-2PN/DP
50 ns
384 KB
315F-2PN/DP
50 ns
512 KB
2Kb256256128Kb
2Kb256256128Kb
??
Unrestricted / © Siemens NV 2017.Page 36
Overview
STEP 7 V5.x STEP 7 V11/12è V13 SP1 STEP 7 V14
„Migrate Project“
„Upgrade“
S7-300S7-400
S7-300S7-400
S7-300S7-400
S7-1500
S7-300S7-400
„Migrate toS7-1500“
S7-1500
„Migrate toS7-1500“
Unrestricted / © Siemens NV 2017.Page 37
Overview
STEP 7 V5.x STEP 7 V11/12è V13 SP1 STEP 7 V14
„Migrate Project“
„Upgrade“
S7-300S7-400
S7-300S7-400
S7-300S7-400
S7-300S7-400
Unrestricted / © Siemens NV 2017.Page 38
1
3
2
§ Migration of engineering data(Availability of hardware testable by Readiness Check Tool)
§ Check the migration log and change the project if necessary
§ Compile the migrated project and resolve detected errors/warnings
Migration steps
Unrestricted / © Siemens NV 2017.Page 39
Hardwareconfiguration
With modules can be migrated• All modules of the STEP 7 V5.5 project must be in the TIA-portal hardware
catalog• Important: Most of the modules which are actively marketed at the
01.10.2007 are included in the hardware catalog (readiness check tool)
No longer actively marketedat the deadline
Unrestricted / © Siemens NV 2017.Page 40
Step 1: Migration of the engineering data
Start migration…èProject Migrate,..• Portal view• Project view
Migrate dialog• Source: STEP 7 V5.5 project• Target: Path for TIA-portal project
Filetype• *.S7P à STEP 7 V5.x project• *.HMI àWinCC flexible project• *.am12 à Migrationfile
Project to be migrated
Destination
Progress
Unrestricted / © Siemens NV 2017.Page 41
Start migration – with/without hardware
Default without hardware
Unrestricted / © Siemens NV 2017.Page 42
Step 2: Check of the migration log
Display of migration messages in the inspector area• Direct link to respective editor
Display of migration log …• Dialog at the end of the migration• Folder „Logs“ in project navigation• Properties of the project
Unrestricted / © Siemens NV 2017.Page 43
Step 3: Compile of the migrated project
After a successful migration the user has to adjust the project ifneccessary. Only a consistent program can be downloaded.
Possible errors:
The STEP 7 V5.5 project needs to beconsistent for the migration. If there areerrors the migration will be aborted withan error message.
Most common error,…
Unrestricted / © Siemens NV 2017.Page 44
Achive block consistency
Solution:Check the block consistency beforeyou start the migration.Compile the program afterwards
Check the blockconsistency
Compile
1
212
Unrestricted / © Siemens NV 2017.Page 45
Precondition of the migrationError free project,…
Create a copy of youprogram with „Save as…“
… with reorganization (slow)!
BeforeBefore migrating,… TIP:
Unrestricted / © Siemens NV 2017.Page 46
Overview
STEP 7 V5.x STEP 7 V11/12è V13 SP1 STEP 7 V14
S7-300S7-400
S7-1500
S7-300S7-400
„Migrate toS7-1500“
S7-1500
„Migrate toS7-1500“
Unrestricted / © Siemens NV 2017.Page 47
1
3
2
§ Migration to S7-1500 (right-click on the S7-300 or S7-400 CPU)
§ Check the migration log and change the project if necessary
§ Compile the migrated project and resolve detected errors/warnings
Migration steps
S7-300
S7-400
S7-1500
Unrestricted / © Siemens NV 2017.Page 48
Step 1Start migrate PLC
Open project with S7-300/400 andcompile the projectStart migrate to S7-1500
1
2
12
S7-1500 S7-1200 S7-300/400/WinAC
Only the PLC will be migrated!Central modules and peripheralstations will not be changed and
have to be reconfigured /reconnected by the user
Unrestricted / © Siemens NV 2017.Page 49
Step 1Choose S7-1500
Choose new S7-1500 plcfor example CPU 1516-3PN/DP
3
3
S7-1500 S7-1200 S7-300/400/WinAC
Unrestricted / © Siemens NV 2017.Page 50
Step 1Security Advice S7-1500 S7-1200 S7-300/400/WinAC
Before the migration will be started the user must confirm asecurity advice
§ Program could be modified during the migration
§ Manual corrections might still be necessary
§ Test the program under security conditions
Unrestricted / © Siemens NV 2017.Page 52
Step 3After migration S7-1500 S7-1200 S7-300/400/WinAC
After the migration the new PLCexists beside the old PLC
Alle new PLCs have to becompiled