WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

26

Transcript of WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

Page 1: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.
Page 2: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

WELCOME

TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT

Page 3: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

CONTROL CENTER

The Brain of the process. Each switch controls a valve or a pump. Analog analyzers can be used to monitor parameters at a glance.

Page 4: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

SCADAINTERFACE

Operations are performed, recorded, monitored, and analyzed through this Interface.

Page 5: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

LAB

Water quality parameters are routinely measured and recorded here.

Page 6: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

LAB

Chlorine residual is measured by introducing a reagent to a sample cell containing finished water. The sample is measured in the spectrometer.

Page 7: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

MICROBIOLOGICAL LAB

Weekly samples from the distribution system are tested for coliform bacteria here. Lake samples are also processed and reviewed here.

Additional tests are run at independent laboratories.

Page 8: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

PROCESS AREA

This room houses the bulk chemical tanks and feed pumps used to inject chemicals.

Page 9: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

ALUMINUM SULFATE- COAGULANT

Used to increase the size of the matter to be filtered by chemically bonding impurities.

Page 10: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

CATIONIC POLYMER- COAGULANT

Helps to produce larger floc, conditions filters.

Page 11: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

POLYALUMINUMCHLORIDE- COAGULANT

Used during high algae periods in lieu of Alum and Cat Poly.

Page 12: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

SODIUM HYPOCHLORITE- DISINFECTION

Added to deactivate any bacteria that may come in contact with the finished water.

Page 13: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

SODIUMHYDROXIDE- PH ADJUSTMENT

A base, used to increase pH to a suitable level to prevent pipe corrosion and ensure palatable drinking water.

Page 14: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

HYDROFLUOSILICICACID- FLUORIDATION

A consumers vote in 1965 mandated the district add fluoride toprevent tooth decay.

Page 15: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

POLYPHOSPHATE

Used to form a lining inside pipes to inhibit the leaching of lead and copper.

Page 16: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

PUMPROOM

China Lake water travels by gravity to the base of these pumps where it is lifted roughly 20’ through the clarifiers.

Page 17: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

PIPEGALLERY

Water is directed to and from the filters through a network of pipes and valves.

Page 18: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

FILTER BAY

3 upflow Clarifiers and 6 Granular Activated Carbon Filters remove impurities from the raw water.

Page 19: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

BOILER ROOM

Two boilers installed in 2011 replace 6 boilers from 1992Expected Annual Fuel savings - 30%

Page 20: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

GENERATOR ROOM

Used to run the process in the event of power failure.

Page 21: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

CLEARWELLS

2 million gallons of storage enables required contact time for chlorine reaction.

Page 22: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

LAGOONS

When the filters and clarifiers becoming overloaded with floc, they must be backwashed

or flushed. This water is sent to a lagoon. When the lagoon becomes full it is taken offline

and allowed to dry before the material and scraped and transported away.Check out our PROJECTS tab for more information about exciting new

uses for this waste product!

Page 23: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

Boilers 2011Chemical Feed Pumps 2011-2013PLC 2011-2012

UPGRADES

Page 24: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

We are in the process of upgrading ourchemical feed pumps. The new pumpswill give us more control and enhancedsafety.

Milton Roy Positive Displacement Pump

Thermo Scientific Peristaltic Pump

Page 25: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

The analog board will soon be a distant memory as we have commenced work on A new programmed logic controller (PLC). This board will disappear and be replaced

By additional features on the existing SCADA system.

Page 26: WELCOME TO THE KENNEBEC WATER DISTRICT FILTRATION PLANT.

THANK YOU FOR TOURING OUR FACILITY!

We would be happy to walk you through the plant in person.Please call (207) 923-3358 to schedule a visit.