Welcome IP Basic - ABB Group · ABB-Welcome IP bus 3. +27 V, GND: ... (cause need APP and multi IS)...

53
Welcome IP Basic

Transcript of Welcome IP Basic - ABB Group · ABB-Welcome IP bus 3. +27 V, GND: ... (cause need APP and multi IS)...

Welcome IP Basic

01 Product portfolio

02 Planning

(1) capacity

(2) power consumption rule

(3) distance rule

03 Commissioning

(1) device detail

(2) commission overview

a. addressing b. programming access

04 Typical sample

(1) planning

(2) commissioning

June 13, 2017 Slide 2

Agenda

01 Product portfolio

Product portfolio

June 13, 2017 Slide 4

Indoor station Building outdoor station

Villa outdoor station

Mini outdoor station

Card reader Guard unit

Power supply IP Gateway Lift control module Relay module Management software

02 Planning

1. One power supply can support 8 ISs or 6 OSs (maximum).

2. If there are more than 1 IS in one apartment, it should need a IP Gateway.

3. If customer needs virtual indoor station function, it should need a IP Gateway.

4. If customer wants to avoid public access to their private devices(IP camera, KNX devices, etc), it should need a IP Gateway.

5. The following devices can be powered by PoE* switch or local power supply: 7 indoor station, Building outdoor station, Villa outdoor station, Mini Outdoor station.

6. The following devices can only be powered by local power supply: IP gateway, card reader, lift control, relay module, guard unit.

Tips

Planning

June 13, 2017 Remark: PoE follows 802.3af regulation.Slide 6

Capacity

Planning

June 13, 2017 Slide 7

Perapartment

PerBuilding

Public Persystem

Distance Unlimited Unlimited Unlimited Unlimited

Channel 2+1 32 (*) 32 (*) /

Building 999

Guard unit 32 32

Property management software 32 32

Outdoor station 4 (connected to public network)32 (connected to home network) 64 32 ~ 8 M

Indoor station 8 ~ 16 M

Apartment ~ 2 K ~ 2 M

Access control 9 32 ~ 9 K

IP camera 256 256 ~ 512 M

Power consumption rule

Planning

June 13, 2017 Slide 8

Device Powered by PoE switch

Power by local PS Consumption YSM01

capacity

Indoor station X X 300 mA @ 27 VDC

Rated: 2500mA @ 27 VDC

Building outdoor station X X 400mA @ 27 VDC

Villa outdoor station X X 250mA @ 27 VDC

Mini outdoor station X X 400mA @ 27 VDC

Card reader - X 100mA @ 27 VDC

Guard unit - X 300mA @ 27 VDC

IP Gateway - X 100mA @ 27 VDC

Lift control module - X 60mA @ 27 VDC

Relay module - X 300mA @ 27 VDC

Distance rule

Planning

June 13, 2017 Slide 9

LAN cable (Cat5E, Cat6, Cat7, …) Fiber-optic

100 m > 1 Km

Between any two devices, support maximum 100 meters

Planning-selection of OS

June 13, 2017• *2nd button by default• **2nd button programmedSlide 10

Article H8137xK-S H8137xPx-S H81312Px-A H81362Px-A H81361P1-A

Utility Building OS Villa OS Mini OS Mini OS Secondary OS

Material Stainless steel Stainless steel Aluminum alloy Aluminum alloy Aluminum alloy

Installation FM FM SM FM/Cavity wall FM/Cavity wall

Dimension (mm) 346.8 x 135 x 48.5 273.8 x 135 x 48.5 168 x 99 x 26 180 x 105 x 43 180 x 105 x 43

Camera pixel 1 M 1 M 0.3 M 0.3 M 0.3 MCamera angle 130° 130° 104° 104° 104°

Unlock X X X X -

Unlock by card ID or IC IC and NFC ID ID -

Card capacityBuilding OS: 2,000

Gate station: 40,000

300 64 64 -

Unlock by password X - - - -

03 Commissioning

Device details

Commissioning

June 13, 2017 Slide 12

Indoor station

24.4 mm

1. LCD display2. Talk3. Unlock4. Mute5. Message6. Call guard7. Set8. Power indicator9. Alarm indicator10. Mute indicator

1. LAN port2. Power supply

+27 VDC input +12 VDC output)

4. Door bell5. Power status detection6. 8 alarm zones

Article. no:

H82351-W WhiteH82351-B BlackH82351-G Golden

12

3 4 5

Device details

Commissioning

June 13, 2017 Slide 13

Outdoor station

1. Camera module with light senor & illumination light2. Acoustic module with MIC & SPK3. 128*64 Display module4. Push button or 4*4 keypad module5. Interface for exit button and door status6. Interface for local power and 2 locks connection7. LAN port8. Wiegand output

Article no.:

H81371K-S ID readerH81372K-S IC readerH81371P1-S 1 buttonH81372P1-S 1 button with IC / NFCH81371P2-S 2 buttonH81372P2-S 2 button with IC / NFC

Device details

Commissioning

June 13, 2017 Slide 14

Mini outdoor station

1. Ring indicator2. Communication indicator3. Unlock indicator4. Acoustic module with MIC & SPK5. Push button module6. Connector for door status, exit button and 1st lock7. Connector for 2nd lock and local power supply8. LAN port9. Selection for tone indication and default lock

Article no.:

H81312P1-A 1 button with ID reader, SMH81312P2-A 2 buttons with ID reader, SMH81362P1-A 1 button with ID reader, FMH81362P2-A 2 buttons with ID reader, FMH81361P1-A 1 button

Device details

Commissioning

June 13, 2017 Slide 15

Card reader

1. Infrared receiver2. Indicator (Green)

On for unlockFlash for setting

3. Power indicatorOn for normalOff for abnormal

1. Lock, Door status, Exit 2. Local power supply3. ABB-Welcome 8 bus4. ABB-Welcome IP bus5. Software upgrade6. Wiegand output

1. Device address2. Type selection

On for buildingOff for public

3. WiegandOn for 26 bitOff for 34 bit

Article no.:

YSM14-CR+

Device details

Commissioning

June 13, 2017 Slide 16

Guard unit

1. Power indicator2. Microphone3. Speaker4. SD card slotA. Title barB. Dial keypadC. Status barD. Video display area

1. LAN port2. Power supply

Article No.:

HSM36-GU

Device details

Commissioning

June 13, 2017 Slide 17

Power supply

Article no.:

YSM01-PS

1. Battery low voltage indicator: on when the battery is low

2. Power failure indicator: on when the AC input has lost

3. Work indicator: on when the DE output is normal4. DC output interface and status output5. AC input interface6. Commissioning button *7. Fuse:

Primary (F1): T3.15AL / 250VSecondary(F2): T6.3AL / 250V

Device details

Commissioning

June 13, 2017 Slide 18

IP Gateway

Article no.:

H8301

1. Status indicator:When the device is

powered on and the connection of indoor stations is detected, LED indicator blinks.

After entering the factory reset mode, the indicator lights 3 seconds and then goes off.

1. LAN port: connect to home router

2. Uplink port: connect to ABB-Welcome IP bus

3. +27 V, GND: Power supply4. Reset button:

When the device is powered on, hold this button more than 3 s to enter the factory reset mode.

Device details

Commissioning

June 13, 2017 Slide 19

Lift control module

Article no.:

YSM23-LC

1. ABB-Welcome IP bus2. ABB-Welcome 8 bus3. RS485 BUS

To 3rd party controllerTo relay module

1. LED indicatorGreen flash for ABB-

Welcome IPRed flash for ABB-

Welcome 8

Commission overview-addressing

Commissioning

June 13, 2017

It is connected to building door entry system bus.It is connected to home router while there is IP Gateway in family.It is used for common area.It is used for dedicated building (with lift control function)

Slide 20

Building address Floor address Apartment address

Identifier

Gate station / / / 1 ~ 32

Building outdoor station 000 ~ 999 -7 ~ 63 / 1 ~ 64

Villa / Mini outdoor station (1) 000 ~ 999 01 ~ 63 01 ~ 32 1 ~ 4

Villa / Mini outdoor station (2) / / / 1 ~ 32

Indoor station (1) 000 ~ 999 01 ~ 63 01 ~ 32 /

Indoor station (2) / / / 1 ~ 8

IP Gateway 000 ~ 999 01 ~ 63 01 ~ 32 /

PMO software / / / 1 ~ 32

Guard unit / / / 1 ~ 32

Card reader (3) / / / 1 ~ 32

Card reader (4) 000 ~ 999 / / 1 ~ 9

Lift control module 000 ~ 999 / / /

Relay module / / / 1 ~ 16

Commissioning

June 13, 2017 Slide 21

1. Open any password input menu.

2. Enter “A12037” to enter engineering mode.

(Press and hold “0” to input “A”)

7 inch indoor station

Commissioning

June 13, 2017 Slide 22

1. Enter “#*345678#” to enter engineering mode from stand-by menu. (345678 is the default password)

Outdoor station

Commissioning

June 13, 2017 Slide 23

1. Connect Mini outdoor station to public network bus by LAN cable

2. Press and hold the first button for 3 seconds to enter engineering mode within 3 mins after devices is power on. (If device is factory default setting, there is not 3 mins constraint)

3. Enter indoor station engineering mode and select outdoor station configuration.

4. Search & set parameter for this villa outdoor station.

Mini outdoor station

Commissioning

June 13, 2017 Remark: indoor station should not be in “IPgateway” mode.Slide 24

1. Connect villa outdoor station to indoor station directly by LAN cable

2. Press “set” button on villa outdoor station rear side at least 3s, during power on to enter engineering mode.

3. Enter indoor station engineering mode and select “Private OS” configuration.

4. Search & set parameter for this villa outdoor station.

Villa outdoor station

Commissioning

June 13, 2017 Slide 25

1. Get its IP-address from indoor station status bar “i”. (or from your router device)

2. Connect your PC/Laptop/Tablet/smart home to router.

3. Open web browser and input IP-address to login.

4. Enter user name and password to login (default user: admin, default password : admin).

IP Gateway

Commissioning

June 13, 2017 Slide 26

1. Open any password input menu.

2. Enter “A12037” to enter engineering mode. (Press and hold “0” to input “A”)

Guard unit

04 Typical sample

Sample 1

Typical sample

June 13, 2017 Slide 28

Requirements:1 Front door1 Rear door4 Indoor stations in basement/1st floor/2nd floor/attic4 Apps

Devices:1 building Outdoor station1 villa OS / mini Outdoor station4 Indoor stations1 PoE Switch 1 IP Gateway (cause need APP and multi IS)1 Power supply (for IP gateway)

Villa

Single villa topology

Topology

Steps

Typical sample-1

June 13, 2017 Slide 29

1. Configure OS1, OS2 via IS; (IS should be in “Not IP Gateway” mode);

3. Configure IP Gateway;

2. Configure all IS;

4. Configure phone;

1. Configure OS1, OS2 via IS

Typical sample-1

June 13, 2017 Slide 30

Press “setting button " on indoor station

■ Click "Advanced setting" then input programming password and click "OK".

(Default programming password is "A12037". To get "A" by holding number "0" for a while.)

Mini outdoor station as Rear door

1. Configure OS1, OS2 via IS

Typical sample-1

June 13, 2017 Slide 31

Choose "Private OS" tab, then click "Search" to find mini outdoor station. Click "OK" to confirm.

Click "Active" to take effect. If change Address, it will restart outdoor station.

Mini outdoor station as Rear door

1. Configure OS1, OS2 via IS

Typical sample-1

June 13, 2017 Slide 32

① To set release time for 2 locks. (1-10 s, default is 5 s)

② To set default lock of outdoor station.

③ ID only, support normal IC card; ID plus, support IC card with key.

④ This function is suit for the case including multi indoor stations within an apartment. If enable, new indoor stations need an authorization to release the lock. Please find details in system manual.

Mini outdoor station as Rear door

1. Configure OS1, OS2 via IS

Typical sample-1

June 13, 2017 Slide 33

Pre-condition:

This outdoor station should connect to Indoor station via LAN cable directly.

1. Press and hold set button at least 3 s when power is on. You will notice round pushbutton module light on.

2. After about 20 s, round pushbutton module flash. It means outdoor station is in engineering mode.

Villa outdoor station as Rear door

1. Configure OS1, OS2 via IS

Typical sample-1

June 13, 2017 Slide 34

3. Press set button on indoor station, click "Advanced setting" then input programming password and click "OK". (Default programming password is "A12037". To get "A" by holding number "0" for a while.)

Villa outdoor station as Rear door

1. Configure OS1, OS2 via IS

Typical sample-1

June 13, 2017 Slide 35

4. Choose "Private OS" tab, then click "Search" to find outdoor station. Click "OK" to confirm.

Click "Active" to take effect. If change Address, it will restart OS.

.

Villa outdoor station as Rear door

1. Configure OS1, OS2 via IS

Typical sample-1

June 13, 2017 Slide 36

① To set release time for 2 locks. (1-10 s, default is 5 s)

② To set default lock of outdoor station.

③ ID only, support normal IC card; ID plus, support IC card with key.

④ To set Wiegand output format

⑤ This function is suit for the case including multi indoor stations within an apartment. If enable, new indoor stations need an authorization to release the lock. Please find details in system manual.

Villa outdoor station as Rear door

2. Configure all IS

Typical sample-1

June 13, 2017 Slide 37

1. Press set button on indoor station, click "Advanced setting" then input programming password and click "OK". (Default programming password is "A12037". To get "A" by holding number "0" for a while.)

2. Stick “IP Gateway”, and then fill in different ID No for each IS, e.g. 01, 02, 03, 04.

3. Configure IP Gateway

Typical sample-1

June 13, 2017 Slide 38

1) Connect wifi of the route

2) Login IP-Gateway by admin.

You can find IP-gateway address via pressing “I” on the left and press “I” again on the right. (user name: admin; password: admin;)

3) Add user and assign permission from user management entry.

IP Gateway setup

IP Gateway setup

3. Configure IP Gateway

Typical sample-1

June 13, 2017 Slide 39

IP Gateway setup

3. Configure IP Gateway

Typical sample-1

June 13, 2017 Slide 41

3. Configure IP Gateway

Typical sample-1

June 13, 2017 Slide 42

4) Enter the specified DynDNSaddress in the "External IP / Hostname" field from Network configuration entry (option for remote access)

5) Logout IP-Gateway by admin.

6) Login IP-Gateway by user added in previous step, then there is one configuration QR code over there.

IP Gateway setup

4. Configure phone

Typical sample-1

June 13, 2017 Slide 43

You can down load the app for your smartphone / tablet via the following two ways: scan QR code on the indoor station from status bar “i”. There will be two QR code, one for IOS, another one for Android. You can input “buschjaeger” into APP store to search for an APP named “Welcome App”, and down load.

APP installation

IOS Android

4. Configure phone

Typical sample-1

June 13, 2017 Slide 44

1) Open the app

2) Click “setting/network settings”

3) Click “Quick configuration with QR-code” and scan the QR code available in 1st step.(Option) Enter IP-Gateway IP address, user name and password added in 1st step,

APP configuration

Requirements:

4 Buildings

- 30 floors per building

- 8 apartments per floor

- 5 entries on 1st floor

1 guard house

5 gate

Devices:

960 Indoor stations (1*8*30*4)

25 Outdoor station (5*4+5)

1 Guard Unit

1 Power supply

121 PoE Switch (30*4+1)

Overview

Typical sample-2

June 13, 2017 Slide 45

1. Connect all devices

Typical sample-2

June 13, 2017 Slide 46

Residential complex topology

Guard house

Building A

……

Build

ing B

Build

ing C

Build

ing D

Steps

Typical sample-2

June 13, 2017 Slide 47

1. Configure indoor stations

2. Configure outdoor stations and gate stations

3. Configure Guard Unit

1. Configure indoor stations

Typical sample-2

June 13, 2017 Slide 48

Press “setting button " on indoor station

■ Click "Advanced setting" then input programming password and click "OK".

(Default programming password is "A12037". To get "A" by holding number "0" for a while.)

1. Configure indoor stations

Typical sample-2

June 13, 2017 Slide 49

Configure each indoor station.

Fill in Block No and Unit No for each indoor station. All IS within the same building should have the same Block No, and different Unit No for different apartment.

1. Configure indoor stations

Typical sample-2

June 13, 2017 Slide 50

001-0101,

001-0102,

001-0108,

001-0201,

001-0202

001-0208;

……

001-3001,

001-3002,

001-3008;

002-0101,

002-0102,

002-0108,

002-0201,

002-0202

002-0208;

……

002-3001,

002-3002,

002-3008;

004-0101,

004-0102,

004-0108,

004-0201,

004-0202

004-0208;

……

004-3001,

004-3002,

004-3008;

003-0101,

003-0102,

003-0108,

003-0201,

003-0202

003-0208;

……

003-3001,

003-3002,

003-3008;

Building 1 Building 2 Building 3 Building 4

2. Configure outdoor stations and gate stations

Typical sample-2

June 13, 2017 Slide 51

Gate station No:

01,

02,

03,

04,

2. Configure outdoor stations and gate stations

Typical sample-2

June 13, 2017 Slide 52

Block No: 001;

Device No:

01,

02,

03,

04,

05,

Block No: 002;

Device No:

01,

02,

03,

04,

05,

Block No: 004;

Device No:

01,

02,

03,

04,

05,

Block No: 003;

Device No:

01,

02,

03,

04,

05,

Building 1 Building 2 Building 3 Building 4

3. Configure Guard Unit

Typical sample

June 13, 2017 Slide 53

Press “Unlock” button and input password (“A12037”).

Set guard unit No here.

1. 2.