WEATHERTEX CONSTRUCTION DETAILS
Transcript of WEATHERTEX CONSTRUCTION DETAILS
AUSTRALIA SEPTEMBER 2020
WEATHERTEX CONSTRUCTION
DETAILS
CAVITY & STEEL FRAME
CONSTRUCTION
WEATHERGROOVE PANELS
INTERNAL LINING
INSULATION
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
TIMBER/STEEL STUD FRAME
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
SMALL EXTERNAL LF
ALUMINIUM CORNER TRIM
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - SMALL EXTERNAL LF CORNER
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 21.07.20 CD-CF-1 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
INSULATIONINTERNAL LINING
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
TIMBER/STEEL STUD FRAME
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
SMALL INTERNAL LF
ALUMINIUM CORNER TRIM
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - SMALL INTERNAL LF CORNER
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-2 A421.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
SMALL TRADITIONAL EXTERNAL
ALUMINIUM CORNER TRIM
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
INTERNAL LINING
INSULATION
TIMBER/STEEL STUD FRAME
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - SMALL EXTERNAL TRADITIONAL CORNER
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 07.07.20 CD-CF-3 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
SMALL TRADITIONAL INTERNAL
ALUMINIUM CORNER TRIM
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
TIMBER/STEEL STUD FRAME
INSULATIONINTERNAL LINING
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - SMALL INTERNAL TRADITIONAL CORNER
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-4 A421.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
SMALL END STOP (SELFLOK, WEATHERGROOVE, ECOWALL, RUBIC RANGES)
LARGE END STOP (PRIMELOK, CLASSIC RANGES)
POLYURETHANE SEALANT APPLIED TO
MANUFACTURERS REQUIREMENTS
ALTERNATIVE BUILDING MATERIAL
E.G. MASONRY, CONCRETE ETC.
9.5mm WEATHERTEX CLADDING
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
TIMBER/STEEL STUD FRAME
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
6mm CONTROL GAP
9mm BACKING ROD
PACKING
DAMPCOURSE
CAVITY CLOSER INSTALLED
AT BASE OF WALL
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
DRAWING NAME:
CAVITY FIX INSTALLATION - END STOP SEPARATION FROM
ALTERNATIVE BUILDING MATERIALS (ALL RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 21.07.20 CD-CF-7 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
WINDOW REVEAL
PACKING
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
INTERNAL LININGARCHITRAVE
INSULATION
WINDOW FRAME
POLYURETHANE SEALANT
WEATHERTIGHT
SEALING TAPE
DECORATIVE TRIM (IF REQUIRED)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED
AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - WINDOW FRAME JAMB
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-8 A4
WINDOW MEMBRANE TRIM DETAIL TO BE INSTALLED TO AS4200.2:2017 Fig 4.7
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
ARCHITRAVE
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
WEATHERTIGHT SEALING TAPE
INSULATION
PACKING
DECORATIVE TRIM (IF REQUIRED)
TIMBER/STEEL STUD FRAME
INTERNAL LINING
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
RUBBER SILL FLAP
WINDOW FRAME
POLYURETHANE
SEALANT
WINDOW REVEAL
DRAWING NAME:
CAVITY FIX INSTALLATION - WINDOW FRAME SILL
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-9 A4
WINDOW MEMBRANE TRIM DETAIL TO BE INSTALLED TO AS4200.2:2017 Fig 4.7
27.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
WINDOW REVEAL
WINDOW HEAD
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
WEATHERTIGHT SEALING TAPE
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
WEATHERTIGHT SEALING TAPE
DECORATIVE TRIM (IF REQUIRED)
CAVITY CLOSER
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGE)
ARCHITRAVE
INTERNAL LINING
HEAD FLASHING MIN 15 °
(TO EXTEND 50mm EITHER SIDE OF WINDOW)
10mm MIN BOARD CLEARANCE
FROM FLASHING
DRAWING NAME:
CAVITY FIX INSTALLATION - WINDOW FRAME HEAD
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-10 A4
WINDOW MEMBRANE TRIM DETAIL TO BE INSTALLED TO AS4200.2:2017 Fig 4.7
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
TIMBER/STEEL STUD FRAME
METER BOX
INSULATION
POLYURETHANE SEALANT
INTERNAL LINING
SMALL END STOP
POLYURETHANE SEALANT
(WHERE METER BOX EXTENDS
THROUGH INTERNAL WALL)
GAP FILLER ROD
GAP FILLER ROD
(WHERE METER BOX EXTENDS
THROUGH INTERNAL WALL)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED
AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - METER BOX JAMB
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-14 A4
METER BOX TRIM DETAIL TO BE INSTALLED TO AS4200.2:2017 Fig 4.7
21.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
POLYURETHANE SEALANT
POLYURETHANE SEALANT
(WHERE METER BOX EXTENDS
THROUGH INTERNAL WALL)
FLASHING MIN 15°
INSULATION
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
METER BOX
GAP FILLER ROD
(WHERE METER BOX EXTENDS
THROUGH INTERNAL WALL)
GAP FILLER ROD
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
INTERNAL LINING
TIMBER/STEEL STUD FRAME
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
WEATHERTIGHT SEALING TAPE
CAVITY CLOSER TO RUN LENGTH OF METER BOX
10mm BOARD CLEARANCE
FROM FLASHING
DRAWING NAME:
CAVITY FIX INSTALLATION - METER BOX HEAD
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-15 A4
METER BOX MEMBRANE TRIM DETAIL TO BE INSTALLED TO AS4200.2:2017 Fig 4.7
21.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
METER BOX
POLYURETHANE SEALANT
SMALL END STOP
INSULATION
INTERNAL LINING
POLYURETHANE SEALANT
(WHERE METER BOX EXTENDS
THROUGH INTERNAL WALL)
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
GAP FILLER ROD
GAP FILLER ROD
(WHERE METER BOX EXTENDS
THROUGH INTERNAL WALL)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
TIMBER/STEEL STUD FRAME
DRAWING NAME:
CAVITY FIX INSTALLATION - METER BOX SILL
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 21.07.20 CD-CF-16 A4
METER BOX MEMBRANE TRIM DETAIL TO BE INSTALLED TO AS4200.2:2017 Fig 4.7
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER
10mm MIN BOARD CLEARANCE
FROM FLASHING
FOLDED METAL HEAD FLASHING MIN 10°
TAPE FLASHING IF INSTALLED AFTER MEMBRANE
PACKING BLOCK
EXTERNAL DOOR JAMB
ARCHITRAVEEXTERNAL DOOR
TIMBER STUD FRAME
INSULATION
INTERNAL LINING
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
DRAWING NAME:
CAVITY FIX INSTALLATION - DOOR HEAD
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-20 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
INTERNAL LINING
TIMBER STUD FRAME
100mm CLEARANCE
SEALED GROUND
225mm CLEARANCE
UNSEALED GROUND
GROUND
INSULATION
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
CAVITY CLOSER
20-30mm
SLAB OVERHANG
CONCRETE SLAB
DRAWING NAME:
CAVITY FIX INSTALLATION - CONCRETE SLAB GROUND CLEARANCE
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-22 A421.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
SUSPENDED FLOOR
LOAD BEARING FRAME
TIMBER/STEEL STUD FRAME
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
CAVITY CLOSER
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
WEATHERTEX CLADDING TO EXTEND MIN 50mm
PAST LOWEST PART OF THE SUSPENDED
FLOOR FRAME
INSULATION
INTERNAL LINING
ANT CAPPING
EMBOSSED POLYTHENE
DAMPCOURSE
PACKING PLATE
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
DRAWING NAME:
CAVITY FIX INSTALLATION - CLADDING OVER PIER
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 22.07.20 CD-CF-24 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
DO NOT CONNECT WEATHERTEX
CLADDING TO MASONRY
PACKING PLATE
SUSPENDED FLOOR FRAME
INTERNAL LINING
TIMBER/STEEL STUD FRAME
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
MASONRY VENEER
TIMBER FRAME
DAMPCOURSE
CLADDING
INSULATION
WEATHERTEX CLADDING TO EXTEND MIN 50mm
PAST LOWEST PART OF THE SUSPENDED
FLOOR FRAME
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
DRAWING NAME:
CAVITY FIX INSTALLATION - FLUSH WITH VENEER
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 22.07.20 CD-CF-26 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
BRICK VENEER
10mm BOARD CLEARANCE
FROM FLASHING
FLASHING
FLOOR FRAME
TIMBER/STEEL STUD FRAME
WEEP HOLES @ MAX 1200 CENTRES
ABOVE FLASHING
CAVITY CLOSER
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE,
ECOWALL, RUBIX RANGES)
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
INTERNAL LINING
INSULATION
60mm WEATHERTIGHT SEALING TAPE
DRAWING NAME:
CAVITY FIX INSTALLATION - SET BACK OVER BRICK VENEER
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 22.07.20 CD-CF-28 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
EAVE/SOFFIT
TIMBER/STEEL STUD FRAME
INTERNAL LINING
FLOOR FRAME
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
INSULATION
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE,
ECOWALL, RUBIX RANGES)
CAVITY CLOSER
DRIP EDGE
QUAD QUAD
DRAWING NAME:
CAVITY FIX INSTALLATION - CANTILEVER ROOF
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-30 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(SELFLOK, WEATHERGROOVE
ECOWALL, RUBIX RANGES)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER
TIMBER/STEEL STUD FRAME
INSULATION
INTERNAL LINING
70mm MIN CLEARANCE
FROM ROOF
RAFTER
ROOFING
METAL FLASHING BY BUILDER 10° MIN
TO EXTEND 50mm BEHIND CLADDING
TAPE IF MEMBRANE CONTINUES BEHIND FLASHING
DRAWING NAME:
CAVITY FIX INSTALLATION - ROOF CLEARANCE
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-32 A427.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
ROOFING
TIMBER STUD FRAME
INTERNAL LINING
INSULATION
ROOFING
EAVE/SOFFIT QUAD
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(PRIMELOK, CLASSIC RANGES)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
DRAWING NAME:
CAVITY FIX INSTALLATION - EAVE/SOFFIT
(SELFLOK, WEATHERGROOVE, ECOWALL, RUBIX RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-34 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
WEATHERGROOVE JOINER
INTERNAL LINING INSULATIONTIMBER/STEEL STUD FRAME
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERTEX CLADDING
(WEATHERGROOVE RANGE)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED
AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - WEATHERGROOVE JOINER
(WEATHERGROOVE RANGE)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-39 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
2mm BUTT JOIN (LEFT OPEN)
INTERNAL LINING INSULATIONTIMBER/STEEL STUD FRAME
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
9.5mm WEATHERGROOVE NATURAL
POLYURETHANE SEALANT
100mm ALCOR FLASHING
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
CAVITY CLOSER INSTALLED
AT BASE OF WALL
DRAWING NAME:
CAVITY FIX INSTALLATION - BUTT JOIN
(WEATHERGROOVE NATURAL)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-43 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
SMALL Z FLASHING
(TOP PANEL TO BE INSTALLED ABOVE Z FLASHING NIB)
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
ROTATED OR DOUBLE NOGGING
INTERNAL LINING
TIMBER/STEEL STUD FRAME
50X50mm ROTATED PACKER TO MATCH
CAVITY BATTEN DEPTH @ FASTENER LOCATION
STEEL FRAMES REFER TO WEATHERTEX
EXTERNAL CLADDING INSTALLATION MANUAL
DO NOT INSTALL CONTINUOUS BATTEN/THERMAL BREAK
ON HORIZONTAL MEMBERS
9.5mm WEATHERTEX CLADDING
(WEATHERGROOVE, ECOWALL RANGES)
INSULATION
DRAWING NAME:
CAVITY FIX INSTALLATION - SMALL Z FLASHING
(WEATHERGROOVE, ECOWALL RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-DF-46 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
Z FLASHING
(TOP PANEL TO BE INSTALLED ABOVE Z FLASHING NIB)
FASTENING PATTERN REFER TO
PRODUCT INFORMATION IN
WEATHERTEX EXTERNAL CLADDING
INSTALLATION MANUAL
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
ROTATED OR DOUBLE NOGGING
INTERNAL LINING
TIMBER/STEEL STUD FRAME
60X60mm ROTATED PACKER TO MATCH
CAVITY BATTEN DEPTH @ FASTENER LOCATION
STEEL FRAMES REFER TO WEATHERTEX
EXTERNAL CLADDING INSTALLATION MANUAL
DO NOT INSTALL CONTINUOUS BATTEN/THERMAL BREAK
ON HORIZONTAL MEMBERS
INSULATION
9.5mm WEATHERTEX CLADDING
(WEATHERGROOVE, ECOWALL RANGES)
DRAWING NAME:
CAVITY FIX INSTALLATION - Z FLASHING
(WEATHERGROOVE, ECOWALL RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART CD-CF-47 A427.07.20
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.
SMALL CORNER
VAPOUR PERMEABLE MEMBRANE
AS SPECIFIED IN WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
Z FLASHING BUTT JOINED
WITH CORNER
TIMBER/STEEL STUD FRAME
9.5mm WEATHERTEX CLADDING
(WEATHERGROOVE, ECOWALL RANGES)
CAVITY BATTEN (TIMBER FRAME)
THERMAL BREAK (STEEL FRAME)
REFER TO WEATHERTEX EXTERNAL
CLADDING INSTALLATION MANUAL
ROTATED PACKER TO MATCH
CAVITY BATTEN DEPTH @ FASTENER LOCATIONS
STEEL FRAMES REFER TO WEATHERTEX
EXTERNAL CLADDING INSTALLATION MANUAL
O NOT INSTALL CONTINUOUS BATTEN/THERMAL BREAK
ON HORIZONTAL MEMBERS
DRAWING NAME:
CAVITY FIX INSTALLATION - Z FLASHING INTO CORNER
(WEATHERGROOVE, ECOWALL RANGES)
SCALE: DRAWN BY: SHT SIZEDATE: DRAWING No.:CHECKED BY:
NTS A.MOATE R.STUART 27.07.20 CD-CF-48 A4
These drawings are for information only. They donot contain full details required for constructionand must be used in conjunction with the currentissue Weathertex Installation Manual, NationalConstruction Code and any other State and LocalRegulations. Weathertex recommends gainingprofessional advice to ensure the drawings aresuitable for your project. Weathertex accepts noliability in respect to the use of these drawings.