We are (A)NABL Accreditation (A)NABL Accreditation at Lab and Site for : a) Energy & Power b) CT/PT,...
-
Upload
lisa-rhoden -
Category
Documents
-
view
237 -
download
8
Transcript of We are (A)NABL Accreditation (A)NABL Accreditation at Lab and Site for : a) Energy & Power b) CT/PT,...
We are We are
(A)(A) NABL Accreditation NABL Accreditation at Lab and Site for :
a) Energy & Power
b) CT/PT, Open Access Connection Metering Unit
c) Dead Weight Tester
(B) Transformer, CT/PT, Energy Meter, Conductor Testing
(C)(C) NABL Accreditation NABL Accreditation at Lab and Site for Mechanical, Thermal and Electro-technical
(D) Training and Consultancy
(E) Research and Development Centre
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
A Primary A Primary Standard NABL Standard NABL
Accredited Accredited LaboratoryLaboratory
(A) (A) C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Calibration Laboratory (NABL C-0768; lab and site ) : -
Energy and Power
FIRST FIRST IN IN
INDIAINDIA
FIRST IN INDIA NABL accredited laboratory to calibrate the reference meter of 0.02 Class at Site.
Equipped with COM 3003 Zera Germany, master with direct traceability to NPL India and DKD Germany.
Calibration meeting the requirements of Electricity Regulatory Board.
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Laboratory (NABL C-0768; lab and site ) : -
Energy and PowerElectricity Electricity Regulatory Regulatory
BoardBoardFacility for calibration of ABT meter, Energy Meter, LT/HT Accuchek, Energy meter calibrator, Power meter /Analyzer, CT/PT Burden Box, Meter Test Bench/ Source, Reference Standard.
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
CT / PT Calibration
Facility for calibration of Standard CT / PT , AC High Voltage and CT / PT Test set .
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur
Energy , Power & CT ,PT Calibration Electricity Electricity Regulatory Regulatory
BoardBoardParameter Capability
Power / Energy 1Ø/ 3 Ø ; 40V to 320V, 40 Hz to 70 Hz, 1mA to 120 A 0.01% of rdg
Power Factor 0.00011 PF
Frequency 40Hz to 70 Hz 0.025%
CT up to 2000A Ratio ErrorPhase Error
0.03%2.5 minute
PT up to 33 kV Ratio Error Phase Error
0.08%4.0 minutes
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur
NABL Accredited Laboratory (NABL C-0769; lab and site ) : -
PressurePrimary Primary
Standard for Standard for DWTDWT
Primary Standard for Dead Weight Tester Calibration upto 1200 kg/cm2 using Cross Float Method.
Equipped with DH-Budenberg UK Dead Weight Tester of Class 0.007% rdg Traceable to UKAS, UK.
Facility for calibration of DWT, Pressure Calibrator, Master Pressure Gauge, Pressure Transmitter, Transducer, Digital Pressure Indicator etc.
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
(B) C and I Calibrations Pvt. Ltd., Jaipur(B) C and I Calibrations Pvt. Ltd., Jaipur
TestingTesting Testing ActivityActivity
Distribution Transformer
CT/PT
Energy Meter
AAC/AAAC/ACSR Conductor
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
(B) NABL Accredited Calibration Laboratory
C&I Systems Kota-
• 15 years old Calibration Laboratory
• NABL accredited since 2000.
• Currently NABL accredited for Mechanical, Thermal and Electro-technical calibration.
• NABL accredited for site calibration as well.
12+ Years12+ Yearsofof
AccreditationAccreditation
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
NABL Accredited Calibration Laboratory
C&I Systems Kota- Electro-technical (NABL C-0190)
Mechanical (NABL C-0088)
Pressure & Vacuum
Dimension , Angle
Mass & Balance
Volume & Density
Speed
Sound
Force
Temperature & Humidity (NABL C-0191)
12+ Years12+ Yearsofof
AccreditationAccreditation
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
NABL Accredited Calibration Laboratory
C&I Systems Kota-
Our Specialities
Calibration of :
• High Voltage AC up to 100 kV & DC up to 35 kV
• Hygrometers (Humidity )
• Volume
• Hydrometer (Density)
• Medical Instruments like BP Instrument , Centrifuge, Incubator, Glass wares, Burette , Pipette etc.
12+ Years12+ Yearsofof
AccreditationAccreditation
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
NABL Accredited Calibration Laboratory (Mechanical)
C&I Systems Kota-
Discipline Parameter Capability
Pressure Pressure Calibrator, Gauges, Transducer, Tx, 0-400 Kg/Cm2 0.04% FS
Vacuum Vacuum Calibrator, Gauges, Transducer 0.045% FS
Spirit Level Up To 300mm 16 µm/m
Dimension Vernier, I/S, O/S Micrometer, Dial Gauge, Height Gauge, Borge Gauge, Feeler Gauge, Bore Gauge, Feeler Gauge, Measuring Tape/ Scale
0-1000 mm
Mass & Balance
Weights 1mg To 20kg Balance Up To 100kg
0.008 mg to 0.73g 0.12 mg to 2.689g
Our Coverage Our Coverage AndAnd
CapabilitiesCapabilities
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
NABL Accredited Calibration Laboratory (Mechanical)
C&I Systems Kota-
Discipline Parameter Capability
Volume 10 µl To 5 ltr. 0.02 µl – 0.065 ml
Speed (RPM) Tachometer (upto 50000 RPM) 0.02% FS Sound Sound Level Meter 94db, 114db 0.53 dB Density Hydrometer 0.6 to 2 g/ml 0.0013 g/ml
AngleBevel Protector/Combination Set / Clinometer 00-3600
3. 6 min.
ForceTension 0.1kN - 50kN, Compression 40kN - 2000kN
0.5%0.7%
Our Coverage Our Coverage AndAnd
CapabilitiesCapabilities
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
NABL Accredited Calibration Laboratory (Electro-technical)
C&I Systems Kota-
(
Discipline Parameter Capability
Electro- technical
Power / Energy 63 V To 415 V,10 mA to 500 A 0.065 % to 0.5 % Power Factor 0.0055 PF Frequency Up To 10 Mhz 0.004% Current(AC/DC) 10 µA to 1000A Voltage(AC/DC) Up to 1000 V
0.03%-0.9% 0.005% - 0.5%
Resistance 0.001Ω T0 400 MΩ Insulation Resistance Up To 2GΩ
0.013%-0.93% 2.4%
Inductance 10 µH To 10H 0.35% - 0.55% Capacitance 10nF To 10mF 0.13% - 1.45%
Our Coverage Our Coverage AndAnd
CapabilitiesCapabilities
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
NABL Accredited Calibration Laboratory (Electro-technical)
C&I Systems Kota-
Discipline Parameter Capability
Electro- technical
High Voltage AC 100kV High Voltage DC 35kV
0.7% to 2.8% 2.9%
Oscilloscope Time Mark 2ns To 5 S Band Width 600 MHz 5mv To 120V
0.014%-0.13% 3.46% 0.3%
Time (Stop Watch) 0.37 Sec-0.7 Sec. Turn Ratio Up To 2000 Turn 0.12%-1.5% Temp. Simulator/Indicator 0.02o C-0.26%o C
Our Coverage Our Coverage AndAnd
CapabilitiesCapabilities
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
NABL Accredited Calibration Laboratory (Thermal)
C&I Systems Kota-
Discipline Parameter Capability
TemperatureRTD. T/C, Thermometer, Bath , Oven, Furnace - 350C to 12000C
0.10C - 2.40C
Humidity 20% to 90% RH 2.06%
Our Coverage Our Coverage AndAnd
CapabilitiesCapabilities
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
Module Type of Training
Power and Energy
Principles & Techniques in Power & Energy Calibration and Uncertainty of Measurement
CT / PT Principles & Techniques in CT/PT Calibration and Uncertainty of Measurement
Electrical Calibration
Voltage, Current, Resistance, Watt Meter, Oscilloscope, Digital Multimeter and Uncertainty of Measurement
Mechanical Calibration
Dimension, Mass & Volume, Pressure & Vacuum, Force, Speed, Sound etc. and Uncertainty of Measurement
Thermal Calibration
Temperature & Humidity Calibration and Uncertainty of Measurement
TrainingTrainingByBy
ExpertsExperts
(D) Training and Consultancy
Technical Training on Calibration -
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
Standard Certification / Accreditation
ISO/IEC 17025 Testing and Calibration Laboratories
ISO 15189 Medical Laboratories
NABH, QCI Hospitals and Health Care units
ISO 9000, ISO14000, TS16949
Industries / Public Sectors / Govt. Institutions
ISO 22000 Food Industries / Food Outlets
ConsultancyConsultancyfor for
Value additionValue addition
Training and Consultancy
Consultancy -
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
Area Type of R&D
Our Patent Patent File No 1271/DEL/2012 for “ A PROCESS for treating dye house waste water for reclamation & reuse”
Waste Tyre Waste Tyre Pyrolysis for recovery of value added products
Solar Energy Solar Applications for Energy Conservation
Water Purification Water purification using Magnetic De-scaling
Effluent Water Treatment
Recovery & reuse of Effluent Water for zero Water Discharge
Our PatentOur PatentAndAnd
Other ResearchOther Research
(E) Research and Development
Sectors Covered -
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical
Contact us at [email protected]
Visit us at www.cicpl.in
C&I Systems, KotaC&I Systems, Kota NABL Accredited Calibration
Laboratory for Mechanical, Electro-technical and Thermal
C and I Calibrations Pvt. Ltd., JaipurC and I Calibrations Pvt. Ltd., Jaipur NABL Accredited Primary Standard
Calibration Laboratory for Mechanical & Electro-technical