Wavin: Range 600 Inspection ChambersProduct Technical Guide

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 2: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

2 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 3

Contents

IntroductionAdoptable drainage: scope 3

New rules for access chambers 3

Regulations for Access ChambersChambers for adoptable areas 4

Chambers for non-adoptable areas 4

Range 600 IntroductionRange 600 inspection chambers 5

Range 600 Product DetailsBase options 6-7

Shaft 7

Cover & Frame options 7

Accessories and spares 8

Installation GuidanceTransportation, handling and storage

on site 8

Chamber and shaft 9

Cover & frame 10-11

Backdrop connections 12

Testing & Maintenance 13

Advice and General InformationWavin Chambers ranges summary 14

Wavin total solutions 14

Fig.1: Adoptable and non-adoptable drainage

Foul water

Surface water

Indicates where Range 600 Inspection Chambers may typically be installed.

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 3: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

2 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 3

Public Footpath

Access in Public Area

8.60 8.60

RB(4)h HB

Boundary

Introduction

Lateral drains and sewers that serve two

or more properties, and connect to the

UK public sewerage network, are now the

responsibility of the relevant Water and

Sewerage Company [WASC].

See Figs.1 and 2 for typical layouts

according to the principles of Sewers for

Adoption 7th edition [SfA7].

For regulations and typical details specifically

applicable to Inspection Chambers in

adoptable applications, see pages 4-5.

Non-adoptable drainageDrains that only serve individual properties

remain the responsibility of each house-

holder. These are still subject to Building

Regulations Part H1, see page 4.

Adoptable drainage: scope

Fig.2: Lateral sewers and drains: typical SfA7 layout example

New rules for access chambersKey changes affecting design and specificationDesign and installation of inspection

chambers in adoptable applications are

now subject to the following:

NEW 7th edition of Sewers for Adoption (SfA7) published 2012SfA7 standardises all relevant performance

criteria, newly-defined design detailing,

and installation standards for all adoptable

drainage networks – including manholes

and inspection chambers.

Flexible (plastic) deep inspection chambers now authorisedSfA7 now incorporates Typical Access

Chamber Details for flexible material

(= plastic) versions of Chamber Type 4

(see Fig.3).

Rigid traditional concrete chambers are no

longer the only authorised type that may be

used for adoptable drainage installations

down to 3 metres.

NEW standards for chamber design specifications

Inspection Chambers manufactured

from plastics are now required to

comply fully with BS EN 13598

– Part 1 – for installations down to

maximum 1.2* metres invert depth

– Part 2 – for installations down to

maximum 3 metres invert depth

*NOTE: For chambers with 450mm minimum diameter.

For smaller chambers (min. dia. 190mm) max invert depth is 0.9m.

Key Foul Water Surface Water

Private drain run

Osma SIC/MBIC (0.6>0.9m deep)

Osma UIC (<1.2m deep)

Adoptable Sewer

Wavin Range 200 (SfA7 – Type 4)

Wavin Range 315 (SfA7 – Type 4)

Wavin Range 600 (SfA7 – Type 3)

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 4: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

4 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 5

Typical details Wavin chambers for Sewers for Adoption

(Type 3 / 4) installations can fully comply with

all relevant specifications within the standard

details reproduced here (see Fig.3).

These include requirements for correct

installation of covers and frames suitable

for the anticipated loading of each location,

in accordance with Classifications under

BS EN 124.

Regulations for Access Chambers

Chambers for adoptable areas

Cover & Frame complying with BS EN 124 and BS 7903 for driveways, footways and landscaped areas – Class B125

Minimum internal dimensions180mm diameter or 225mm x100mm

150mm deep concrete collar

Garden

Granular bedding material

DOT Type 1 sub base (thickness varies)or concrete surround

Base unit to have all connections with a diameter greater than 150mm set at soffits level

Joints between base and shaft components to be fitted with watertight seals

Minimum radius to be 500mmfor a 100mm diameter pipe and600mm for a 150mm diameterpipe to allow entry ofmaintenance equipment

Driveway

Fig.3: Typical Access Chamber Detail – Type 4 (Flexible material detail) Maximum depth from cover level to soffit of pipe 2m, non entry

Typical details for chambers sited in driveways/paved areas

For installation guidance specifically

applicable to Range 600 Inspection

Chambers for Type 3 / 4 installations, see

page 9 – General Installation, page 12 –

Backdrops.

For typical details and installation guidance

specifically applicable to Covers & Frames

options, see pages 10-11.

Non-adoptable drainage: Building Regulations still applyFor drains that are not part of the newly-

extended adoptable areas, Part H1 of the

Building Regulations is still applicable.

These include minimum dimensions for

circular inspection chambers, and for

covers, as follows:

Chambers for non-adoptable areas

TypeDepth to invert from cover level

(m)

Internal size (mm)

Cover sizes

Length x width (mm) Circular (mm)

Shallow 0.6 or less 190* – 190

1.2 or less 450 430 x 430 430

Deep > 1.2 450 300 x 300** Restricted access to max. 350mm**

* Drains up to 150mm

** Size restricted for Health & Safety reasons. Larger openings may be used in conjunction with a restricted access.

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 5: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

4 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 5

Range 600 Introduction

Description600mm diameter polypropylene inspection

chambers for adoptable and non-adoptable

applications. Compliant with Sewers for

Adoption 7th edition [SfA7].

Choice of twelve bases for equal pipe

connections.

For use directly with 150mm, 225mm

and 300mm UltraRib system. For use

with other 150mm, 225mm and 300mm

plastic pipework and clay pipework via the

appropriate adaptor.

600mm diameter shaft may be cut to length

to achieve required invert up to maximum

3000mm.

Applicationsl For above ground access and

maintenance inspection of buried

pipework up to 3 metres deep

l For loading applications:

– B125 (12.5 tonnes) *

– D400 (40 tonnes) *

* with cover & frame supported by

concrete plinth

Key Dimensionsl Invert depth of base:

– 646mm [for 150mm system]

– 705mm [for 225mm and 300mm

systems]

l External shaft diameter: 683mm

l Shaft length: 3m

l Maximum installation depth: 3m

Range 600 Inspection ChambersKey Features & Benefitsl Fast, easy installation: no wet trades

l Lightweight: no lifting equipment required

l Reinforced base plate to withstand

groundwater pressure

l Shaft can be cut to required length

l All inlets and outlet sockets allow ≤7.5˚

movement in all directions

ComplianceRange 600 chambers comply with the

following standards and regulations

– BS EN 13598-2:2009 a

– SfA7 Typical Chamber Detail – Type 3:

(Non-entry. Maximum depth from cover

level to soffit of pipe: 3m)

– Building Regulations – Part H1 (type Deep,

to maximum depth >1.2m)

Range 600 chamber assembly

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 6: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

6 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 7

Range 600 Inspection Chambers Product Details

All Range 600 bases are polypropylene and supplied with a base-to-

shaft sealing ring.

When used in adoptable applications, maximum invert depth 3m.

Bases

D/S Equal Inspection Chamber Base a – straight channel only

l 600mm dia. base straight channel and single inlet

l For use with 150mm, 225mm and 300mm UltraRib

l Also for use with 150mm, 225mm and 300mm clay pipework,

using Adaptor TA/2 (150mm), Adaptor TA/4 (225mm), or

Adaptor TA/7 (300mm)

l Also for connection to 150mm, 225mm and 300mm TwinWall

using Adaptors 6TW145 (with150 Base), 9TW145 (with 225

Base) or 12TW145 (with 300 Base)

D/S Equal Inspection Chamber Base a – bent 30˚ channel only

l 600mm dia. base incorporating bent 30˚ channel and single inlet

l For use with 150mm, 225mm and 300mm UltraRib

l Also for use with 150mm, 225mm and 300mm clay pipework,

using Adaptor TA/2 (150mm), Adaptor TA/4 (225mm), or

Adaptor TA/7 (300mm)

l Also for connection to 150mm, 225mm and 300mm TwinWall

using Adaptors 6TW145 (with150 Base), 9TW145 (with 225

Base) or 12TW145 (with 300 Base)

Nominal Size (mm)

Part Number

Dimensions (mm)A B C D E F G

150 66NE300 720 720 - 150 720 646 207

225 69NE300 720 720 - 225 720 705 207

300 612NE300 720 720 - 300 720 705 207

B

C A

D

B

C A

D

B

C A

D

E

F

E

F

E

F

D/S Equal Inspection Chamber Base a – bent 90˚ channel only

l 600mm dia. base incorporating bent 90˚ channel and single inlet

l For use with 150mm, 225mm and 300mm UltraRib

l Also for use with 150mm, 225mm and 300mm clay pipework,

using Adaptor TA/2 (150mm), Adaptor TA/4 (225mm), or

Adaptor TA/7 (300mm)

l Also for connection to 150mm, 225mm and 300mm TwinWall

using Adaptors 6TW145 (with150 Base), 9TW145 (with 225

Base) or 12TW145 (with 300 Base)

Nominal Size (mm)

Part Number

Dimensions (mm)A B C D E F G

150 66NE314 720 720 - 150 720 646 207

225 69NE314 720 720 - 225 720 705 207

300 612NE314 720 720 - 300 720 705 207

Nominal Size (mm)

Part Number

Dimensions (mm)A B C D E F G

150 66NE315 720 720 - 150 720 646 207

225 69NE315 720 720 - 225 720 705 207

300 612NE315 720 720 - 300 720 705 207

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 7: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

6 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 7

Range 600 Inspection Chambers Product Details

B

C A

D

E

F

ShaftP/E Inspection Chamber Shaftl 600mm dia. plain-ended shaft. Length: 3 metres

l For use with all Range 600 bases

Nominal Size (mm)

Part Number

Dimensions (mm)A B**

600 60NE003 683 3000

A

B

Bases

Restriction Access CapRestriction Access Capl For use with 60NE003

l Restricts access to 350mm

l Supplied with one 600mm sealing ring

Nominal Size (mm)

Part Number

Dimensions (mm)A B

600 60NE930 704 270

A

B

** Dimension B = effective height

D/S Equal Inspection Chamber Base a – straight channel with two 90˚ branches (left and right)

l 600mm dia. base incorporating straight channel and three inlets

including 2 x 90˚ equal branch inlets

l For use with 150mm, 225mm and 300mm UltraRib

l Also for use with 150mm, 225mm and 300mm clay pipework,

using Adaptor TA/2 (150mm), Adaptor TA/4 (225mm), or

Adaptor TA/7 (300mm)

l Also for connection to 150mm, 225mm and 300mm TwinWall

using Adaptors 6TW145 (with150 Base), 9TW145 (with 225

Base) or 12TW145 (with 300 Base)

Nominal Size (mm)

Part Number

Dimensions (mm)A B C D E F G

150 66NE316 720 720 - 150 720 646 207

225 69NE316 720 720 - 225 720 705 207

300 612NE316 720 720 - 300 720 705 207

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 8: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

8 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 9

Range 600 Inspection Chambers Product Details

Transportation If chambers are carried on vehicles with

a flat bed, ensure that:

l The bed is free from nails and other

projections.

l Chambers are adequately secured.

HandlingRange 600 polypropylene chambers are

lighter than other, more traditional materials,

yet have excellent strength and impact

Transportation, handling and storage

characteristics. So they are easier to

handle and less likely to be damaged.

However, to minimise risk of damage:

l Load/unload chambers by hand:

avoid use of mechanical handling

equipment if possible.

l If mechanical equipment employed,

use special hoist equipment with

textile straps. Do NOT use metal

hooks or chains.

l Do not drop chambers onto hard

surfaces or drag them along the

ground.

StorageStore chambers on level ground that

is free of stones and sharp objects.

Exercise reasonable care to avoid

damage prior to their installation.

Accessories

Chamber Base to Shaft Seall 600mm diameter for use with 60NE003

Nominal Size (mm)

Part Number

Dimensions (mm)dia.

– 600TW117 600

Spares

Chamber Shaft Cutter components

l For cutting 110/160mm connection holes to receive

plastic pipework in Range 600 Inspection Chamber shaft

Connector Kit

l For connecting 110/160mm plastic pipework to

Range 600 Inspection Chamber shaft

Nominal Size (mm)

Part Number

110 NE955

160 NE965

Nominal Size (mm)

Part Number

110 NE950

160 NE960

Adaptors for clay pipe

l For connecting 100/150mm clay pipe to

chamber base

Nominal Size (mm)

Part Number

100 SA15/1

150 SA15/2

Adaptor for UltraRib pipe

l For connecting 150mm UltraRib pipe to

chamber base

Nominal Size (mm)

Part Number

150 6UR141

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 9: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

8 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 9

Installation Guidance

NOTE: The following is a summary of

installation procedures following selection of

a suitable Range 600 Base for the required

number of inlets.

Excavationl Take precautions against trench collapse:

support trench sides deeper than 1.2m.

Preparationl Prepare and compact 100mm regulating

bed of granular material in trench bottom.

Positioning/connectionl Position Base on regulating bed. Check

outlet is facing in the correct direction: i.e.

with side inlets swept to follow water flow.

l Ensure all inlets/outlet are free from dirt

or grit.

l Use standard jointing sequence

to connect 150mm, 225mm or 300mm

UltraRib pipes to inlets/outlet.

For connection of TwinWall pipes in these

sizes, use Adaptors 6TW145, 9TW145 or

12TW145

If connecting to 150mm, 225mm or

300mm Hepworth Clay, insert the

appropriate adaptors into the required

inlet/outlet as follows:

– 150mm Clay use Adaptor TA/2

– 225mm Clay use Adaptor TA/4

– 300mm Clay use Adaptor TA/7

NOTE: The main through channel MUST

be used. Bends up to 45° may be used on

any inlet or outlet.

Backfilll Using same material as bedding,

backfill around Base in 150mm layers

up to underside of shaft socket.

Ensure inside of Base is free of debris.

Preparing shaftl Cut corrugated shaft to approx. Invert

depth of Chamber.

RECOMMENDATION: leave extra 300mm

depth to allow for possible final site changes.

l Locate sealing ring between 2nd and 3rd

ribs from shaft bottom. Ensure ring is

seated correctly/not twisted.

l Clean inside of Base socket and lubricate

this entire area.

Installation guidance: chamber and shaft

Driveway

Cover & Frame Class B125 loading

Class B engineering bricksset in class 1 mortar

150mm deep concrete collar

Shuttering to external cap

600mm dia Shaft

Compacted backfill –‘as-dug’ or granularbedding material

150mm, 225mm or300mm dia Pipe

Granular bedding material

Restrictor cap 600mm diato 350mm dia

Fig. 4: Typical installation detail: Range 600 Inspection Chamber. Type 3

l Position shaft at 45° angle into Base

socket. Vertically push home manually or,

if required, with mechanical assistance

(if so, protect top of shaft).

Backfill trenchl Before starting backfill, cover top of shaft

to prevent ingress of dirt or grit.

Trafficked application (e.g. roadway)l Follow Highway Specification: use

Type 1 or similar backfill, and compact.

Non-trafficked application (e.g. garden area)l Use “as-dug” material (excluding stones

>40mm dia., frozen or vegetable matter) in

300mm layers. Tamp mechanically around

full circumference of Base so that current

conditions re ground and water table, and

anticipated future loading, can be

supported.

RECOMMENDED SPD LEVELS:

– Green areas 90%

– Paved areas/limited traffic load 95%

– Roads/heavy traffic loads 98%

l Avoid knocking shaft during backfilling –

and keep free of debris.

l Backfill to formation level.

Trim shaft/fit restriction access cap l Trim shaft to required height using fine-

toothed saw.

NOTE: If finished ground level is not yet

known, leave shaft proud of surface and

keep open end covered until final completion.

l When shaft trimmed to final height, locate

sealing ring between 2nd and 3rd ribs from

shaft top. Ensure ring is seated correctly/not

twisted.

l Lubricate inside of 350mm restrictor cap,

position over top of shaft, and push fully

home.

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 10: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

10 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 11

Car Surface

Cover & Frame Class B125 loading

150mm deep concrete collar

Shuttering to external cap

600mm dia Shaft

Compacted backfill –‘as-dug’ or granularbedding material

150mm, 225mm or300mm dia Pipe

Granular bedding material

Restrictor cap 600mm diato 350mm dia

Installation Guidance

Use the appropriate Cover and Frame to

suit application area/function:

A15 – non-loaded green/landscaped areas

only accessible to pedestrians and bicycles

B125 – paved areas with limited traffic load,

where heavy vehicles do not have access

D400 – roads with heavy duty traffic loads

Galvanised cover and framesGalvanised options are recommended for

A15 applications.

For A15 applications in areas such as

domestic gardens and/or applications

subject to occasional/temporary loading

up to 15kN (1.5 tonnes) such as domestic

driveways, the frame should always be

supported by a concrete plinth. (See Fig. 5).

Ductile iron covers and framesDuctile iron options are recommended for

heavier loaded applications:

Class B125 - with medium duty loading

capacity of 125kN (12.5 tonnes) where the

frame is supported by a concrete plinth.

Suitable for applications such as car parks

and service roads.

Class D400 classification - with loading

capability of up to 400kN (40 tonnes) where

supported by a concrete plinth. Suitable for

carriageways and roads subject to motor

vehicle trafficking.

Installation guidance: cover and frame

Fig.5. Installation detail A15 –domestic gardens and/or areas subject to occasional

vehicle loading up to 15kN (1.5 tonnes)

Installation procedures:

For A15 applications in domestic garden areas and/or subject to occasional vehicle loading up to 15kN (1.5 tonnes) (See Fig.5)

EXAMPLE: domestic driveways

l Leave top 150mm of shaft clear of backfill

l Lay 150mm thick slab of pre-cast or in

situ concrete around top of shaft chamber

l Prepare A15 Cover and Frame for instal-

lation in accordance with manufacturer’s

instructions

l Position the cover and frame socket

on top of slab and fix in accordance with

manufacturer’s instructions

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 11: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

10 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 11

Installation Guidance

Installation guidance: B125 & D400 cover and frame

Driveway

Cover & Frame Class B125 loading

Class B engineering bricksset in class 1 mortar

150mm deep concrete collar

Shuttering to external cap

600mm dia Shaft

Compacted backfill –‘as-dug’ or granularbedding material

150mm, 225mm or300mm dia Pipe

Granular bedding material

Restrictor cap 600mm diato 350mm dia

Installation procedures:

For B125 - Paved areas with limited traffic load and for D400 – Roads with heavy traffic loads

l Trim shaft section at last stage of

construction. Ensure unit is at correct

height.

l Protect shaft from traffic loading by

shuttering its external ribs.

l Lay 150mm thick slab of pre-cast or in

situ concrete around top of shaft chamber

with minimum opening 750mm x 750mm

– or 750mm diameter – to ensure that any

loads are distributed away from the shaft.

l On top of slab, construct Class B

engineering brickwork OR concrete blocks

OR pre-cast concrete seating rings up to

required height.

l According to required loading application,

position the appropriate Cover and Frame

on top of slab. (See Fig.6)

Fig.6. Installation detail for B125 loading: paved areas with limited traffic load; and for

D400 loading: roads with heavy traffic loads

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 12: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

12 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 13

Installation Guidance

A chamber which has substantially different

invert levels will require backdrop connection

of one or more drains. This operation can

be done externally on site. (See Fig.7)

Use a combination of Backdrop Kit [NE950

or NE960], with associated 100/110mm or

150/160mm fittings, for in situ connection to

a 600 shaft, as follows:

l Drill required opening into corrugated

shaft section at appropriate place

l Clean and remove any swarf from the

opening

Fig.7. Installation detail – typical backdrop situation

Installation guidance: backdrop connections

Restrictor cap 600mm diato 350mm dia

Driveway

Cover & Frame Class B125 loading

Class B engineering bricksset in class 1 mortar

150mm deep concrete collar

600mm dia Shaft

Compacted backfill –‘as-dug’ or granularbedding material

150mm, 225mm or300mm dia Pipe

Granular bedding material

l Install the special 110mm or 160mm seal

into the opening

l Fully lubricate around the entire internal

surface of the seal

l Insert specially designed “in-situ” socket

connector into the seal opening

l Lubricate the outside surface of the spigot

pipe to be connected and insert into the

socket connector

l Make remaining connections in the same

way as for standard jointing of 110mm or

160mm pipes and or fittings

Installation of backdrop connections

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 13: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

12 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 13

Installation Guidance

All testing of these non-man entry

chambers and connecting pipework must

be undertaken at ground level.

For guidance, please use the following:

Air Testing using remote test bags: equipment requiredl 3 x 1 metre x 8mm Steel Drainage Rods

l 50mm Double Worm Screw for use with

Steel Drainage Rods

l PVC sealing bags fitted with Schrader

Valve and 6 metre hose.

l Steel drain plug with testing point

l Bicycle Pump

l Tyre pressure gauge to ensure correct

inflation pressure of the test bags.

Air Testing procedure1. Assemble drain rods to 3 metres in length

with double worm attachment on end.

2. Remove as much air as possible from the

PVC Sealing Bag.

Method: hold valve open and squeeze

bag flat.

Tip: folding the bag in half to make it

as small as possible will make it easier

to locate.

3. Twist neck of PVC Sealing Bag into

double worm attachment until it has

firm grip on bag.

4. Ensure valve end of hose is secure with

no danger of falling down the chamber.

5. Hold drain rods and hose from the PVC

Sealing Bag together. Start to lower the

test bag into the base.

Tip: Keep hose tight while lowering bag.

This helps to keep bag in place.

6. When bag is in chamber base, position it

into the channel of the run to be tested.

7. By using the channel as a guide, slide test

bag into the mouth of the pipe, and as far

as possible into the pipe.

Method: use rods to push bag into

position.

8. Leave rods attached (this ensures bag is

held in position). Start to pump the bag

up using a bicycle pump.

NOTE: When inflating the test bags, follow manufacturer’s instructions to ensure pressure is not exceeded. Use tyre pressure valve to monitor bag pressure.

9. If required, remove rods by twisting them

in an anti-clockwise direction to release

the double worm. Check the valve end

of hose is safely positioned.

Testing

MaintenanceAs with all Wavin Chambers, the smooth

interior bore of chamber channels and

associated pipe systems will aid the flow

of water and waste through the system.

Because man-entry of Wavin chambers

is not possible, maintenance work

such as Rodding, Jetting and CCTV

inspection must be undertaken at

ground level.

Always follow the Health & Safety and

Operational procedures of equipment

suppliers.

10. Place a similar sealing bag or a steel

drain plug at the other end of the pipe

length to be tested.

(This could be another chamber or a

terminal access point.) Both bag and

steel drain plug must include a suitable

testing point.

11. Attach a manometer. Carry out required

air test method.

12. Remove sealing bag

Method: twist double worm attachment

around the hose at ground level. Lower

it down the hose, guiding the rods to the

bottom of the chamber and once again

grip the bag.

NOTE: No requirement to grip bag

tightly. This is simply to aid its removal.

Release as much air as possible from

bag. Then slide bag back out the pipe

with the rods.

When this is done, lift/remove all test

equipment out of the chamber.

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 14: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

14 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 15

Advice and General Information

Comprehensive choiceWavin Range 600 is part of a comprehensive portfolio of inspection chambers that can

provide the optimum solution for every adoptable and non-adoptable situation.

Wavin Chambers

Base Type Max Invert Depth* (m)

Base Dia. (mm)

SfA7 Type

No. of Inlets Inlet Sizes (mm OD)

1 2-3 4-5 100/110 150/160 160 225 300

Shallow 0.6 250 4* l l

Multi-Base 0.9 300 4* l l

Mini-Access 0.9 315 4 l l

Universal 1.2 450 4* l l l l l

PPIC 1.2 475 4 l l l l l

Range 200 2.0 200 4 l l l

Range 315 2.0 315 4 l l l l

Range 450 3.0 450 3, 4 l l l l l l

Range 600 3.0 600 3, 4 l l l l l

* NOTE: Maximum invert depths shown are for individual base types.

Under SfA7 and Building Regulations, maximum permitted depth can be less.

Our Inspection Chambers are backed by Wavin’s comprehensive technical

advice service. This is available to provide expert assistance at every stage of a

project, from planning and product selection to installation and maintenance.

Contact Wavin Technical Design Department:

Tel: 0844 856 5165

Fax: 01249 766653

Email: [email protected]

or via online enquiry at www.wavin.co.uk

Wavin systems are integrated to provide a

total solution for above and below ground

drainage, water management, plumbing

and surface heating and cooling for the

Building and Construction markets.

Wavin is Europe’s leading supplier of

effective solutions for essential needs of

daily life: safe distribution of drinking water;

sustainable management of rainwater and

waste water; energy-efficient heating and

cooling for buildings.

Technical advice and further Information

Wavin total solutionsAssociated systemsContact Wavin Technical Design Department

for further details regarding:

l Below Ground Drainage systems

l Surface Water Drainage systems

l Stormwater Management systems

Other Wavin systemsl Hep2O Flexible Plumbing system

l Hep2O Underfloor Heating and Cooling

systems

l Rainwater systems

l Soil & Waste systems

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 15: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

14 Customer Services: 0844 856 5152 Technical Advice: 0844 856 5165 15For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected]

Page 16: Wavin: Range 600 Inspection Chambers - MyTub Ltd · Wavin: Range 600 Inspection Chambers Product Technical Guide For latest prices and delivery to your door visit MyTub Ltd - - info@mytub.co.uk

Wavin operates a programme of continuous product development, and therefore reserves the right to modify or amend the specification of their products without notice. All information in this publication is given in good faith, and believed to be correct at the time of going to press. However, no responsibility can be accepted for any errors, omissions or incorrect assumptions. Users should satisfy themselves that products are suitable for the purpose and application intended.

WP004

www.wavin.co.uk

Solutions for Essentials

Wavin: Range 600 Inspection ChambersProduct Technical Guide

Wavin provides effective solutions for essential needs of daily life:

safe distribution of drinking water; sustainable management of

rainwater and waste water; energy efficient heating and cooling for

buildings.

Wavin’s European leadership, local presence, commitment to

innovation and technical support, all benefit our customers.

We consistently achieve the highest sustainability standards

and ensure total reliability of supply to support our customers to

achieve their objectives.