The Efficient Application of an Impulse Source Wavemaker ...
Wavemaker G3 Pipe Screening System Guided Wave Testing Method.
-
Upload
marybeth-summers -
Category
Documents
-
view
265 -
download
7
Transcript of Wavemaker G3 Pipe Screening System Guided Wave Testing Method.
![Page 1: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/1.jpg)
WavemakerG3 Pipe Screening System
Guided Wave Testing Method
![Page 2: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/2.jpg)
2
WavemakerG3 Pipe Screening System
The pipe walls form a guide for ultrasonic waves, which directs them down the length of the pipe
Transducer
Structure
Region of structure inspected
Transducer
Structure
Region of structure inspected
Conventional
Guided waves
Propagation along, not through, a structure
![Page 3: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/3.jpg)
3
WavemakerG3 Pipe Screening System
Reflection from a feature (such as corrosion)
When the guided wave hits a change in cross section (or impedance),it reflects back toward the transducer
Transducer
Structure
![Page 4: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/4.jpg)
4
WavemakerG3 Pipe Screening System
Typical applications
Pipe racks Insulated pipe Pipe with restricted access Road crossings Submerged pipe Buried pipe
![Page 5: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/5.jpg)
5
WavemakerG3 Pipe Screening System
Wide variety of applications
![Page 6: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/6.jpg)
6
WavemakerG3 Pipe Screening System
Guided WavesThe Basics
![Page 7: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/7.jpg)
7
WavemakerG3 Pipe Screening System
Standard UT v Guided Waves
Standard UT high frequency short wavelength sensitive to small
defects at high frequencies
point measurement
Guided Waves low frequency long wavelength sensitive to “small”
defects even at low frequencies
rapid screening
![Page 8: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/8.jpg)
8
WavemakerG3 Pipe Screening System
Key Advantages
In service inspection
Rapid 100% coverage
Limited access required
![Page 9: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/9.jpg)
9
WavemakerG3 Pipe Screening System
Change in cross-sectional area
Method is equally sensitive to defects at any though wall position
Method is sensitive to changes in cross section (increase or decrease)
Reflection from welds and flanges are used as a reference
Amplitude of reflection is scaled with distance
![Page 10: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/10.jpg)
10
WavemakerG3 Pipe Screening System
Weld example
Incoming wave (100% of energy)
Reflected wave(20% of energy)
Transmitted wave(80% of energy)
![Page 11: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/11.jpg)
11
WavemakerG3 Pipe Screening System
At each reflection the transmitted energy becomes less
Incoming wave (100% of energy)
20% 80%
16% 64%
13% 51%
![Page 12: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/12.jpg)
12
WavemakerG3 Pipe Screening System
These effects appear as an amplitude decay
The reflected amplitude from distant features will be smaller than for close features
DAC curves are used to compensate for this
0.0 5.0 10.0 15.0 20.00.0
0.2
0.4
0.6
Distance (m)
Am
p (
mV
)
-F1 -F2 -F3 -F4 -F5
![Page 13: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/13.jpg)
13
WavemakerG3 Pipe Screening System
Symmetry example BLACK lines represent symmetric features
Uniform around the circumference
RED lines represent non-symmetric features Varies around the circumference
-10.0 -5.0 0.0 5.0
1.0
2.0
3.0
Distance (m)
Am
p (
mV
)
+F1 +F2 +F3 +F4-F1-F2-F3-F4A symmetric weld A non-symmetric defect
![Page 14: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/14.jpg)
14
WavemakerG3 Pipe Screening System
The ratio of red to black depends on the circumferential extent of the feature
Circumferential Extent (percent)
When the feature does not extend very far around the circumference
RED = BLACK
When the feature extends significantly around the circumference
RED << BLACK0
0
1
50 100
Am
plitude Ratio
![Page 15: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/15.jpg)
15
WavemakerG3 Pipe Screening System
Determining wall thickness reduction
The remaining wall thickness can never be measured directly by using this technique, which should always be considered a screening tool
It is necessary to prove up any defective areas using a complementary method such as UT thickness measurement or visual inspection
![Page 16: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/16.jpg)
16
WavemakerG3 Pipe Screening System
Wavemaker G3 System Components
![Page 17: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/17.jpg)
17
WavemakerG3 Pipe Screening System
The fixed rings Available for pipe sizes 2”-8” All rings carry unique serial
number which is identified in software
Can be used on pipes up to 180ºC (with special precautions)
Pipe transducers sprung loaded onto pipe
3 inches clearance needed around pipe
![Page 18: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/18.jpg)
18
WavemakerG3 Pipe Screening System
The inflatable rings Available for pipe sizes 6”-36” Rings can be joined to inspect larger
pipes All rings carry unique serial number
which is identified in software Can be used on pipes up to 180ºC
(with special precautions) Air pressure forces transducers onto
pipe using car style foot pump. Transducer modules rapidly switched
between rings (less than 30 mins) 2 inches clearance need around most
of pipe
![Page 19: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/19.jpg)
19
WavemakerG3 Pipe Screening System
Pipe diameters Pipes up to 75 inches (2 metres) in diameter have been inspected Pipes down to ¾ inch (19mm) can be inspected using special rings
![Page 20: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/20.jpg)
20
WavemakerG3 Pipe Screening System
WavemakerTypical performance
![Page 21: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/21.jpg)
21
WavemakerG3 Pipe Screening System
Detection threshold Typically minimum detectable defect is 5% cross
sectional loss
If pipe is in good general condition defects down to 1% have been detected
A 1% defect in a 3” pipe equates to a half wall defect of 5mm (0.2”) diameter
![Page 22: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/22.jpg)
22
WavemakerG3 Pipe Screening System
Diagnostic range In ideal conditions 200m of pipe can be screened in
each direction from a single test location
Typically range on above ground pipe is 50m in each direction
For buried pipes 20m in each direction is more typical unless the pipe is sleeved
![Page 23: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/23.jpg)
23
WavemakerG3 Pipe Screening System
Unrolled pipe ‘C-Scan’ Circumferential orientation can now be determined
accurately
Works best with newly developed 16 channel rings
Gives equivalent information as in-line inspection tools
![Page 24: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/24.jpg)
24
WavemakerG3 Pipe Screening System
Unrolled pipe example
-24d
B
-2.0 0.0 2.0 4.0 6.00
100
200
300
Ang
le (
deg)
-2.0 0.0 2.0 4.0 6.00.0
5.0
10.0
15.0
20.0
Distance (m)
Am
p (L
inea
r)
-F1
-F4
-F2
-F3
-F5
-F6
+F2
+F1
+F3
+F4
+F5
Defect at 150° (close to bottom)
Defect at 50° (close to top)
![Page 25: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/25.jpg)
25
WavemakerG3 Pipe Screening System
WavemakerTypical application examples
![Page 26: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/26.jpg)
26
WavemakerG3 Pipe Screening System
Pipe racks
Pipe racks are generally easy to test. Over 100m can be screened from a single test location.
![Page 27: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/27.jpg)
27
WavemakerG3 Pipe Screening System
Insulated pipes Small section of
insulation removed at each test point
Over 100m of pipe can be screened from each test point
![Page 28: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/28.jpg)
28
WavemakerG3 Pipe Screening System
Overhead pipes Only limited access
needed
Over 100m can be screened from a single test point
![Page 29: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/29.jpg)
29
WavemakerG3 Pipe Screening System
Sleeved road crossings Only external access is
required.
Up to 35m can be screened from a single location depending on coatings
![Page 30: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/30.jpg)
30
WavemakerG3 Pipe Screening System
Wall penetrations Only external access is
required.
Concrete walls up to 1m thick and earth walls up to 20m thick can be screened
![Page 31: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/31.jpg)
31
WavemakerG3 Pipe Screening System
Buried pipes Holes dug at pre-defined
intervals
Around 20m of pipe can be tested in each direction from a single location (depending on pipe, coating and soil conditions)
![Page 32: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/32.jpg)
32
WavemakerG3 Pipe Screening System
Offshore pipe Riser splash-zone
inspection (top side)
Sub-sea pipe inspected using special transducer rings and instrumentation
![Page 33: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/33.jpg)
33
WavemakerG3 Pipe Screening System
Limiting factors General condition of pipe determines detection
threshold and range
Some coatings and coverings (for example earth) reduce range
High external noise, such as compressors, reduce performance
![Page 34: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/34.jpg)
34
WavemakerG3 Pipe Screening System
Effect of pipe contents Gases - no effect
Liquids
No effect when low viscosity
Sludge
Heavy viscous deposits in the pipe attenuate the signal and reduce the test range
![Page 35: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/35.jpg)
35
WavemakerG3 Pipe Screening System
Reporting Automatic reporting feature to increase productivity
All raw data stored for later review and auditing
Reports can be printed directly or imported into other applications
Photographs can be embedded in the report file
![Page 36: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/36.jpg)
36
WavemakerG3 Pipe Screening System
Reporting
Inspection company header Site details including GPS
location, operator and equipment used
List of pipe features with distance, type and operator notes
A-Scan trace showing the post processed data for review
![Page 37: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/37.jpg)
37
WavemakerG3 Pipe Screening System
Training Class and site training
3 operator levels defined
Level 1 can perform basic interpretation,
Level 2 can perform more challenging inspections
Intermediate trainings also available
![Page 38: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/38.jpg)
38
WavemakerG3 Pipe Screening System
New developments
![Page 39: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/39.jpg)
39
WavemakerG3 Pipe Screening System
Tube Inspection System (T-Scan)
![Page 40: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/40.jpg)
40
WavemakerG3 Pipe Screening System
Boiler Tube Inspection (Claw)
Probes for access restriction
![Page 41: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/41.jpg)
41
WavemakerG3 Pipe Screening System
Permanently Installed Rings (PIMS)Special rings can be bonded onto the pipe permanently for use on
any pipe including buried and sub-sea.
![Page 42: Wavemaker G3 Pipe Screening System Guided Wave Testing Method.](https://reader038.fdocuments.us/reader038/viewer/2022102602/56649eec5503460f94bfd7b3/html5/thumbnails/42.jpg)
42
WavemakerG3 Pipe Screening System
NDT Equipment Services157 Central Avenue
BillinghamClevelandTS23 1LF
T 00 44 (0)1642 555575F 00 44 (0)1642 555548
W www.ndt-equipment.co.ukE [email protected]