Water Quality Online Monitoring Device - Environmental XPRT · 2019-07-17 · water quality testing...
Transcript of Water Quality Online Monitoring Device - Environmental XPRT · 2019-07-17 · water quality testing...
Water Quality Online Monitoring Device
Hangzhou Zetian Technology Co., Ltd. , founded in 2008, is located in Hangzhou, Zhejiang Province,
China. We are professional manufacturer of high-tech environmental monitoring equipment, analytical
instruments, industrial process control and industrial safety products.
We have five major products' series; Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer,
water quality testing instruments, air quality monitoring systems, and gas leak alarm. We developed
more than 60 product models for these series, basically covering air and water pollution monitoring,
metallurgical industries, chemical and other on-line monitoring needs. Some of our products include
back-scatter laser dust meter, high temperature humidity meter, denitration escape ammonia analyzer,
sulphur analyzer, trace Cl analyzer system, immersive UV broad spectrum water analyzer, ammonia 2
nitrogen analyzer, colorimetric heavy analyzer, anodic stripping voltammetry heavy metal analyser etc.
We’ve combined integrated fields includ microelectronics, telecommunication, software, electrical and
mechanical engineering and other area of technology. We are among the few worldwide manufacturers
that have proprietary right for gas analysis, water analysis and dust analysis products at the same time.
We're technology innovation oriented driven organization. We trade with many corporate customers,
including domestic and foreign source on-line monitoring / process analysis system integrator; agents,
operation and maintenance providers; equipment manufacturers, thermal power plants, sewage
treatment plants, chemical plants and the like. We provide our clients with highly cost-effective
intellectual monitoring instrumentation and analysis equipment, analysis module / component, CEMS
program sets, complete set of water quality analysis program and other similar products. We accept
OEM, also provides ODM, on behalf of operation and maintenance and other services.
Hangzhou Zetian Technology is committed to the Integrity, Strength and Quality of our products. We're
internationally recognized. We warmly welcome you to visit us for business negotiation and products'
inspection.
ENTERPRISE INTRODUCTIONENTERPRISE INTRODUCTION
Technology Platform Introduction
Hangzhou Zetian Technology Co., Ltd. is the only domestic company with five analysis technical platforms which are
LED colorimetric platform, full spectrum colorimetric platform, cold atomic absorption colorimetric platform, anodic
dissolution platform and electrode method platform. These five kinds of analysis platform can measure the common
pollution factor in water, including COD, ammonia nitrogen, total phosphorus, total nitrogen and heavy metals such as
copper, chromium, lead, zinc, mercury, arsenic, etc. At the same time, using the full spectrum colorimetric platform or
anodic dissolution platform also can realize COD/ ammonia nitrogen integrated machine, total phosphorus/ total nitrogen
integrated machine, and all kinds of heavy metal integrated machine, etc.
The water quality series products of Hangzhou Zetian Technology Co., Ltd. have been experienced years of on-site
validation, stable and reliable, low failure rate. Comparison table of our products and other company's products is listed
below.
Platform Principle Introduction Advantages Disadvantages
LED Platform
Light source adopts high quality imported LED, precise constant current source drives LED, light transmits through the cuvette, and received by the photoelectric detector, using lambert beer's law to measure the concentration of the substance.
Simple measurement platform, low cost, high accuracy, suitable for common instruments, such as COD, ammonia nitrogen device, etc.
(1)In the same circumstances, the absorbance of LED light source spectrum is smaller than that of full spectrum method. (2)High temperature drift , must use reference beam, otherwise, the measurement data has large drift.(3)Generally, devices using LED light source can't measure a variety of factors simultaneously .
Full Spectrum Colorimetric
Platform
Using xenon lamp as light source, which transmits through the colorimeter cell, been detected by the other side of the spectrometer. Spectrometer obtains continuous spectrum from 200 nm to 800 nm bybeam splitter , then using the needed wavelengths, calculates the concentration of the substance based on Lambert. Beer's law.
(1 ) There a re severa l wave leng th po in t s to rea l i ze measurement, turbidity compensation, color saturation compensation and the reagent blank compensation. Suitable for analysis of heavy metal such as total lead, total manganese, total zinc, etc.(2) Unit absorbance of spectrometer is much bigger than that of LED, so detection limit can be lower.(3)Can get partial uv light (200 nm), while normally LED can't get this kind of wavelength.(4)Xenon lamp emits a continuous spectrum, so one device can measure multiple parameters.
(1)Higher cost compared to the LED platform. (2 )Sui tab le fo r mul t i -parameter in tegra ted machine, total nitrogen, heavy metal analyzer , etc.
Anodic Dissolution Platform
Under certain conditions, after electrolytic solution for a certain time, the metal ion deposits on the electrode. Then reversely apply voltage until reaching the oxidation voltage, the metal concentrated on the electrode dissolves out. Measuring according to the electrochemical dissolution curve.
(1) Can detect PPB level of metal content, suitable for heavy metals detection of pollution exits and surface water. ( 2 ) T h e r e a r e m u l t i - p a r a m e t e r s i n t e g r a t e d machine(can simultaneously measure various heavy metals).
(1)Higher cost compared to the colorimetric method. (2) Suitable for good water quality places (in case of poor water quality, can measure with our company's precision filtration equipment).
Cold Atomic Absorption
Colorimetric Platform
Light source adopts imported mercury lamp, which is driven by high voltage power supply. The light transmits through the cuvette (mercury vapor f l o w s t h r o u g h c u v e t t e ) a n d r e c e i v e d b y photoelectric detector, using lambert beer's law to measure the concentration of mercury vapor.
(1)Separate the mercury from water samples to avoid interference of ions, turbidity, chromaticity, etc. (2) Using mercury lamp to measure, it has big absorbance, and improves the detectionlimit.
(1)High costs.
Electrode Method Platform
It is a kind of electrochemical sensors which use membrane potential to measure activity or concentration of ions in the solution. When it contacts with solution which containing ions under test, on phase interface of the sensitive membrane and solution, it produces membrane potential relative to the ion activity.
(1) water sample pretreatment is simple, basically no need reagent;(2) applicable to some water samples of high concentration, without the influence of turbidity, etc.(3) simple maintenance.
(1)Electrode membrane needs regular maintenance and clean.
Zetian Technology Other Company
Peristaltic Pump Tube
The United States imported special rubber hose, long service life, a tube can use more than one year.
General rubber hose, easily go bad.
Sample ModuleHomemade sampling module uses the high pure PTFE material, sample valve imported from Japan, reliable operation, every channel is completely isolated.
Using rotary valve for sampling control, particularly for COD device, selector valve easily leaks, and if damaged, it needs whole replacement, large amount of maintenance.
Control System(1)Control solenoid valve uses non-contact electronic switch, no mechanical life. (2) Homemade control unit, after years of verification, low fault rate, high reliability, modular design, low maintenance cost.
(1)Control solenoid valve uses relay which has a mechanical life and is affected by the moisture, etc. (2) The control unit adopts PLC design, once damaged, it needs high cost of maintenance.
Instrument Protection
It provides instruments protection function as much as possible, such as reagents fault adding warning (especially H SO used in COD, if it is not H SO , it is likely to lead digestion tube 2 4 2 4
burst), leakage protection (if there is leakage, the instrument will report errors), pressure relief valve (making pressure in digestion tube within a certain range).
None, it is likely to lead digestion tube burst.
Grounding Ddesign
All the external interface and main circuit of equipment is in isolation, which makes the normal sample without the outside interference. Especially for unequal potential connection, its effect is particularly evident. External export and internal input are not isolated, communication is not
reliable.In analog circuits (measurement module) also made electrical isolation, which makes the minimum possible interference on measurement.
Measuring PartsModulating optical measurement makes no influence of external light on measurement, it is more stable
Affected by external light, measurement data is not stable.
External Interface
Largest configuration has 2×4-20 mA output, 4×4-20 mA input, 2 switch input, 2 switch output, can access the PH meter, flow meter, ss and other equipment, and can display on the main interface.
Very few external output interfaces.
Technology Platform It has five measuring platforms, suitable for the needs of different applicationsLess technology platform, single product, can't meet the ever-changing market needs
Permanganate Index Water Quality AnalyzerWDet-5000Mn
Instrument use the acidic potassium permanganate oxidation method to
measure the organic matter content of water.Theorganic matter in the
water is dispelled andoxidized by the acidic potassium permanganate at
the temperature of 95℃ .The amount of residual potassium
permanganate is reduced by excess sodium oxalate. Titrate the rest of
thesodium oxalate withpotassium permanganate.The index of
potassium permanganate is calculatedby the consumption of potassium
permanganate.
Product Features
Product Overview
Technical specifications
Acidic potassium permanganate spectrophotometry
No more than ±5%
0 20 50 100mg/L,~ ~ ~ adjustable
Digestion Time 3、5、20、30minutes optional
Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Period Minimum measurement period 45minutes
Span Drift ±5%
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional)
Uncertainty
Interface
Method
Range
Interval
High reliability, low maintenanceCore components are imported, high reliability, long lifetime, suitable for long time online monitoring Water samples are quantified by means of the overflow cup, and reagents flow separately, which reduces the
pollution of the water samples on reagent flow pathWater overflow cup can be used for quantification of bad water qualityAll parts contacted with liquid before delivery will havea special test to ensure that these parts can be used for a
long timeFlow path is not easy to jam through the special design
Accurate measurement, unique designReaction liquid are analyzed by using advanced image recognition technology, and more accurate judgment of the
titration end-point Reagent is quantified by using capacitance metering module, high accuracy, more simple and reliable flow path
designAutomatically adjust the titration speed, high analysis efficiency
Identification methodlike human eye, can quickly identify the consumption of solution directlyA variety of practical function, providing humanized operation
When a reagent leakage, instruments and automatic will alarm and prompt the user for maintenanceEquipment has self-diagnosis function, if there is a defective, it will automatically alarm, and display nameExceed standard sample retained function, abnormal data samples will be retained for handwork analysisSimple equipment operation, the touch screen control panel and friendly software interface, providing abundant
information, the software is simple to understandA digital lock screen, prevent others wrong operation
●
●
●
●
●
●
●
●
●
●
●
●
●
●
WDet-5000Ammonia-Nitrogen Water Quality Online Automatic Analyzer
Wdet - 5000 ammonia-nitrogen water quality online automatic analyzer (salicylic acid
method) based on the salicylic acid spectrophotometric method. In alkaline medium, the
ammonia nitrogen in water samples oxidizes into chloramine by hypochlorite oxidation.
Under the effect of catalyst, it reacts with salicylate to form compounds which have
characteristic absorption at 697 nm. Ammonia nitrogen content in water samples is
calculated by measuring the absorbance of the compounds.
WDet - 5000 ammonia-nitrogen water quality online automatic analyzer (salicylic acid)
can be widely used in ammonia nitrogen monitoring of surface water environment,
industrial depth treatment water sample.
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of actual
water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
Automatic leakage alarming, when reagent leakage appears, instrument self-check alarms, remind maintenance
Abnormal state automatic processing, when a power exception occurs during the operation, the instrument will self-
diagnose abnormal state the next time power restores, and clean flow path to recover sampling status
Easy operation, touch screen control panel and friendly software interface provide abundant information. The
software is easy to understand
A digital lock screen, prevent wrong operation
●
●
●
●
●
●
●
●
●
●
●
Product Features
Technical specifications
Product Overview
Salicylic acid spectrophotometric method
Accuracy:±3% F.S.
Reroducibility:±5% F.S.
0~0.5~2~10mg/L,other range is adjustable
Period Minimum measurement period 15minutes
Automatically adjust the measuring interval, can also be triggered by serial port
Detection Limit 0.05mg/L
Span Drift ±5%
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <2hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional)
Uncertainty
Interface
Method
Range
Interval
Total Phosphorus Water Quality Online Automatic AnalyzerWDet-5000
Under neutral conditions, the sample is digested by potassium
phosphorus converting all of phosphorus into orthophosphate. Then
under acidic conditions, orthophosphate reacts with molybdate and
oxygen antimony potassium tartrate, generating phosphomolybdic acid
that is reduced by ascorbic acid to form blue complex. The amount of
blue complex is proportional to orthophosphate. Measurement by
colorimetric method gets total phosphorus content ultimately.
It applies to the monitoring of pollution sources and surface
water,can also be applied to the detection of the sewage treatment
process.
Method Ammonium molybdate spectrophotometric method
Uncertainty
Range 0.01~10mg/L,adjustable
Interval Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Reproducibility ±3%
Reagent A single set of reagents can measure 250 samples
External
Interface
Maintenance <2hours/month
Working Temp. 5℃~40℃
Power 200W(220±10%VAC 50Hz), regardless of the pump
RS485/RS232/USB interface (optional)Interface
Analog Output:1×4-20mA output (expandable to 2 channel), the
maximum load 500Ω
Analog Input: 1×4-20mA input (expandable to 2 channel),
compatible with 0-5V input, optional
Relay Output: 4 channel (can be flexible configuration)
Molybdate yellow colorimetric method
0.2~100mg/L,adjustable
Product Overview
Technical specifications
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of actual
water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and remind maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm and display
●
●
●
●
●
●
●
●
●
Linearity:±3%
Reproducibility:±3%
Product Features
Total Nitrogen Water Quality Online Automatic AnalyzerWDet-5000
Under more than 60℃ in aqueous solution, potassium persulfate can be
completely decomposed into potassium bisulfate and atomic oxygen, and
at 120℃~ 124℃ conditions, the atomic oxygen can make the nitrogen of
nitrogen compound in water samples element oxidize to nitrate,
andorganic matter are also oxidized and decomposed simultaneously. The
absorbance of water samples is measured by UV spectrophotometry at the
wavelength of 220nm and 275nm. Total nitrogen content is calculated
according to this absorbance.
It applies to the monitoring of environmental pollution, industrial process
water, municipal wastewater treatment.
Product Overview
Technical specifications
Alkaline potassium persulfate digestion - UV spectrophotometry
Reproducibility:±3%
Linearity:±3%
0.05~100~200mg/L,adjustable
Min Period Less than 1 hour
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional)
Uncertainty
Interface
Method
Range
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life..
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of actual
water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and remind maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm and display
●
●
●
●
●
●
●
●
●
Product Features
Immersion Water Quality AnalyzerWDet-5000UVI
WDet-5000UVI is the first full-spectrum (200-800nm)
immersion UV analyzer. Apply to measurement COD,
BOD, UV254, nitrate, TOC, DOC, turbidity, TSS, color
and other indicators of surface water, groundwater,
municipal wastewater.
It uses the pulse xenon lamp as light source, optical fiber
UV spectrometer as the detector, can real-time collect
water pollutants absorption spectrum between 200-800
nm, using chemometrics algorithms technology to real-
time analysis water contaminants. Its light path is
illustrated right:
220VAC,30W
2%F.S.
<1%F.S.
0~50~200mg/L,Greater range can be customized
The shortest 60 seconds, the cycle can be set
<10m
Can be adjusted according to the site conditions
5℃~45℃
IP65(secondary instrument)
Can be set
RS232/RS485 , 4-20mA output(2 channel)(Baud rate can be set)
φ60*380.5mm
5kg
Method
Power
Linearity
Zero Drift
Range(COD)
Interval
Probes Depth
Optical Path
Working Temp.
Enclosure Rating
Auto-cleaning
Interface
Probe Size
Probe Weight
Secondary instrument
Air compressor
Cable Gas circuit
Sewage being measured
Product Overview
Applications Scenarios Technical specifications
Technical Features
Light source
Fiber optic spectrometer
UV/visible differential optical absorption spectroscopy,
wavelength range 200-800nm
Analyzerprobe
1: Compared with the double wavelength background subtraction
technique, full spectrum (200-800nm) measurement technique
and chemometric algorithm allow more parameters to be measured,
and the influence of composition change is small
2: Automatic cleaning of gas probe with high-pressure provides
higher reliability than the mechanical blade
3: No reagents, low operating costs, no secondary pollution
4: Fast response(2s), applicable to real-time requirements of the occasion
5: Interference-free chlorine ion
WDet-5000UVS Extractive Water Quality Analyzer
It applies to the occasion of poor water quality
conditions, such as enterprises pollution exits, sewage
treatment plants entrance, sewage treatment plant
process on-line detection.
Extractive UV water quality analyzer uses full spectrum measurement technique which is the same as immersion water
quality analyzer. It can well improve the situation that optical lens of immersion UV water quality analyzer is easy to be
polluted in the case of poor water quality conditions, and manual maintenance is high. Every time the extractive UV water
quality analyzer measures through extractive liquid into the measuring chamber by the peristaltic pump. After the
measurement, the liquid can be discharged, and measuring pool should be cleaned by clean fluid. Its principle is as
follows:
Cleaningfluid
Peristaltic pump
Fiber optic spectrometer Light source
Measuringcell
Sewage being measured
Product Overview
ApplicationsTechnical Features
1: Measuring pool immerses in the cleaning fluid at ordinary
times, real-time sampling, real-time emptying, high
adaptation to the poor water quality
2: Automatic zero, no maintenance, no scale calibration, only
regular cleaning fluid(composition is dilute sulphuric acid,
consumption is 3 ml each time, configurable by users)
3:Compared with the double wavelength background
subtraction technique, full spectrum (200-800nm)
measurement technique and chemometric algorithm allow
more parameters to be measured, and the influence of
composition change is small
4: Can realize high range measurement (COD up to 10000 mg/L)
5: Fast response (5s) is applicable to occasions of real-time
requirements
6: Interference-free from chlorine ion
This instrument adopts the pulse xenon lamp as light source, optical fiber
UV spectrometer as the detector, collect real-time absorption spectrum of
water quality pollutants between 200-800 nm, using the weighted multi-
wave leng th abso rbance a s say WMW (Weigh ted Wave leng th
absorptiometry), to improve the shortcomings of UV method analyzer.
Taking COD for example, in detection of five typical UV absorption spectra
of the organic matter between 243 nm to 290 nm, according to the UV
absorbance information of full range (it builds a mathematic model of the
spectral data and the COD value, and by using the model extrapolation
ability, according to the absorbance value of unknown samples, it reversely
calculates the COD value of water sample.)
It can achieve the measurement of organic pollutants such as COD, BOD,
etc, widely used in environmental pollution monitoring, surface water
monitoring, municipal sewage treatment.
WDet-5000UV UV Water Quality Online Analyzer
Product Overview
Technical specifications
±5%
COD: 0~200mg/L,higher range can be customized
BOD: 0~200mg/L,higher range can be customized
UV-vis spectrophotometry
Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Reproducibility ±5%
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional)
Range
Interface
Uncertainty
Method
Interval
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life..
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of actual
water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and remind maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm and display
●
●
●
●
●
●
●
●
●
Product Features
MDet-6000XAnodic Stripping Heavy Metal Water Quality Online Analyzer
Analyzer uses electrochemical anodic stripping voltammetry which is
ranked by the US EPA of authority as a standard test method. Stripping
voltammetry is also called reverse stripping polarography, which make
the material be electrolytic a certain amount of time under the ion
polarographic analysis of limiting current potential test. Then change
the electrode potential, make the material gathered on the electrode to
be dissolved. According to the given volt-ampere curve in the
dissolution process for quantitative analysis.
(1) Before testing, the instruments automatically extract the fresh sample to clean sample pipe, metrology pipe and
measurement pool, to ensure that the sample is representative.
(2) The instrument uses the new peristaltic pump technology to sample. Pump pipe does not directly contact with
samples and reagents. The volume of the sample is controlled by an optical measurement system.
(3) Same as sample injection, reagent (buffer, electrolyte, etc.) is absorbed by peristaltic pump. Inhaled volume is
controlled by the optical measurement system. Reagent and water are mixed through the form of the bubble.
(4) Placing a constant voltage on the working electrode, the ion under test restores and dissolves out on the work elec-
trode surface. Then reversely apply a linear change scanning voltage. Metal elemental dissolves on the working elec-
trode, in the electrode circuit it produces characteristic current which feeds back ion concentration in the solution.
(5) Analyzer can use the built-in calibration standard solution and cleaning solution automatically for equipment
calibration and cleaning according to preset cycle.
ØPharmaceutical factory, chemical plants, electroplating factory.
ØLead-acid battery factory.
ØAll kinds of metal factory.
ØSewage treatment plant and other occasions.
Distilled
water
Dig
estion
solu
tion
Ad
justin
g so
lutio
n
Waste fluid bottle
Waste fluid
Waste flu
id
Standard solutionDistilled water
Water sampleAdjusting solution
ElectrolyteChannel valve
OxidantCoating solution
Ten-way valve
Meterin
g tub
e
Reference tank
Digestion tube
Peristaltic pump
Electrolytic tank
Elec t r ic machinery
Continuous, 1, 2, 3...24 hours a day, or triggered by the modbus device
1×4-20 mA output (expandable to 2 channel), 2 multi-function relay output
Components Cadmium, lead, zinc, copper, mercury, arsenic
Method Anodic stripping voltammetry
Range 1ppb~10ppm
Accuracy ±3%(100ppb)
Reproducibility ±5%(100ppb)
Enrichment Time 15s,30s,200s can be set
Interval
Calibration Automatic calibration time, interval can be set
Size 1460*510*410(mm)
Weigh
Working Temp. 5℃~40℃, <95%,no condensationhumidity
Power 100W(220±10%VAC 50Hz), regardless of the pump
Output
Maintenance 15days
Reagent A single set of reagents can measure 250 samples
Preheat Time 2hours
Other Automatic cleaning, data records, print, buzzer alarm
70kg( )exclusive of reagent
Basic Principle
Measurement Process
Applications Analyzer Flow Chart
Technical specifications
Portable Anodic Stripping Heavy Metal AnalyzerPDV-5000X
Analyzer uses anodic stripping voltammetry to detect heavy metals, it has features of low detection limit (up to PPB
level), high precision, stable performance, easy to carry, especially suitable for field operation. Widely used in
monitoring heavy metal content in the water of soil, food, solid material, drinking water, surface water, beverage, water
environment, seawater, industrial waste water.
Typically anodic stripping heavy metal detection process basically includes two steps:
(1)Use oxidant to decompose and convert metals contained in water samples into ions, then under constant potential
which is more negative than its peak potential, digestion solution pre-electrolyzes and gathers on the working electrode
for a certain time.
(2)Scan potential in the direction from negative to positive, make the material
enriched on the electrode oxidation dissolved. And record its dissolution map,
according to the stripping peak potentials to determine the composition of the
material being tested. According to the stripping peak current, the content of
material is measured.
Electrolytic reduction is slow accumulation, dissolution is quickly released, at
the time of dissolution, Faraday current as a signal increases greatly, so that the
sensitivity of method is greatly improved
ØTerminal analysis of the heavy metal sample
content in the laboratory.
ØThe rapid emergency detection of outdoor
environment accident point.
ØThe inspection analysis of industrial process.
Components Cadmium, lead, zinc, copper, mercury, arsenic
Method Anodic stripping voltammetry
Range 1ppb~10ppm
Accuracy ±3%(100ppb)
Reproducibility ±5%(100ppb)
Measuring Time 15s,60s,200s can be set
Battery Life Without external power supply, measuring time with built-in lithium battery can be 4 hours hours continuously
continuous
Size 200*102*55(mm)
Weight 5.3kg( )including the reagent
Working Temp. 5℃~40℃,humidity<95%,no condensation
Power 220VAC( In),12V/1.5A(Out)
Signal Output Bluetooth
Maintenance Depending on the sample analysis cycle(nance
advise before measuring)
mainte-
Reagent Support measuring 50 samples , optional reagent kit with reagent
Preheat Time 2hours
Other Data record and print
Basic Principle
Applications
Technical specifications
1: 240×160 pixel LCD screen
2: Form a complete set of experimental instruments, make the direct analysis possible on scene
3:Multiple sets of measuring cups, it is convenient to continuously measure a variety of samples at the same time
4: Detachable electrode combination, convenient to replace and maintain
5: In addition to the default measurement method, analysis of parameters can be set freely, to facilitate the expansion
of the measurement method
Product Features
WDet-5000 Integrated Water Quality Online Analyzer
WDet-6000X water qualityautomatic analyzer is a high level integration of
multi-parameter water quality analyzer, as upgrade product of WDet-
5000integrated water quality analyzer, analyzer, ituses modular design,
each parameter using independent sample and analysis module, to
realizethe use of any combinationsuch as COD, ammonia nitrogen, total
phosphorus, total nitrogen and a variety of heavy metals.Reagentused by
Instruments can be configured according to relevant national standards
It can be widely used in water pollution monitoring, industrial process
water, industrial and municipal wastewater treatment and surface water
monitoring, etc.
Product Overview
Technical specificationsCOD, ammonia nitrogen, total phosphorus, total nitrogen and part
of heavy metals. The other parameters can be customized
3、5、20、30、40、60、80、100、120min optional
Hourly and interval measurement, can also start the measurementvia a
serial port
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional) Interface
Parameters
Digestion Time
Interval
Product FeaturesHigh reliability, small amount of maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring Water samples are quantified by means of the overflow cup, and reagents flow separately, which reduces the
pollution of the water samples on reagent flow pathWater overflow cup can be used for quantification of bad water qualityAll parts contacted with liquid before delivery will havea special test to ensure that these parts can be used for a
long timeFlow path is not easy to jam through the special design
Modular design, more convenient combinationA single HMI module can connect with multiple analysis module, to facilitate the measurement combinationof the
multiple parameterEach module has independent sample, resolution and measurement function, no cross interferenceStructure design of high compatibility, monitoring modulecan be replaced according to the field requirements
A variety of practical function, providing humanized operationWhen a reagent leakage, instruments and automatic will alarm and prompt the user for maintenanceAutomatic processingof abnormal state, whenpowerexception occurs during the operation, the instrument will
diagnose abnormal state, and clean flow path back to wait for sample statusthe next time power restoresExceed standard sample retained function, abnormal data samples will be retained for handwork analysisSimple equipment operation, the touch screen control panel and friendly software interface, providing abundant
information, the software is simple to understandA digital lock screen, prevent others wrong operation
●
●
●
●
●
●
●
●
●
●
●
●
●
CCOD:low 10% of measuring value,≥40mg/L
low 5mg/L,<40mg/L
Ammonia nitrogen: 3%
Total phosphorus: 3%
Total nitrogen: 5%
Heavy metals: 5%
Accuracy
COD/Ammonia Nitrogen/TPIntegration Water Quality Automatic AnalyzerWDet-5000I
WDet-5000 COD/ammonia nitrogen/TP Integration water quality analyzer is a new kind of automatic on-line analyzer
used for simultaneously measuring ammonia nitrogen, total phosphorus and chemical oxygen demand (UV method) in the
water. Using the latest photoelectric measurement, UV-VIS spectral measurement techniques, it has features of accurate
measurement, high integration, low detection limit, high reliability, strong adaptability, etc. Instrument reagent can be
self-configured in accordance with the relevant national standard.
COD measurement uses the weighted multiwavelength absorbance assay WMW (Weighted
Wavelength absorptiometry) to improve the shortcomings of the UV method analyzer. In
detection of five typical UV absorption spectra of the organic matter between 243 nm to 290 nm,
according to the UV absorbance information of all band, it builds a mathematic model of the
spectral data and the COD value, and by using the model extrapolation ability, according to the
absorbance value of unknown samples, it reversely calculates the COD value of water sample.
1: Full spectrum (200-800nm) measurement techniques, can simultaneously measure COD(UV method),
ammonia nitrogen and total phosphorus
2: Photoelectric non-contact measurement, high measuring accuracy, high reliability
3: Volume of a single sample liquid is less than 9 ml, low operational cost
4: Using high resolution industrial-grade colorized touch screen, easy to operate, rich information
5: Dispense with monitoring cabin, can be directly installed outdoors.
6: Built-in industrial air conditioner, avoid the influence of ambient temperature.
7: Support connections with instrument such as flow meter, PH meter.
COD
Molybdenum yellow colorimetry
±3%F.S.±5%F.S.
0-50mg/L(In terms of phosphorus)
±3%±5%
A single set of reagents can measure 250 samples
Total Phosphorus(TP)
<1hour per month
5℃~40℃
200W(220±10%VAC 50Hz),regardless of the pump
0~200 mg/L~500
200-800nm spectrum
±5%F.S.
±5%
0~10mg/L
Ammonia Nitrogen
Nessler's reagent colorimetric
Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Method
Accuracy
Range
Reproducibility
ExternalInterface
Maintenance
Working Temp.
Type
Measurement
Reagent
UV-vis spectrophotometry
Power
Ultraviolet source
Spectrograph
Reaction tank
Optical fiber
Principle of full spectrum detection
Product Overview
Product Features
Instrument Indexes
Analog output: Each parameter configuration 1 channel
:
output
Analog Input 1×4-20mA input (expandable to 2 channel), compatible with 0-5V input (optional)
Relay Control:4 channel,can be flexibly configured
Communication Interface: RS485/RS232/USB interface (optional)
CODcr Water Quality Online Automatic AnalyzerCODet-5000
CODet-5000 is a new-type on-line automatic analyzer for chemical oxygen demand
(COD) measurement. The instrument uses the latest technology such as optical
measurement, high temperature and high pressure digestion, color integration, etc, has the
feature of accurate measurement, low detection limit, high reliability and good
adaptability, etc.
CODet-5000 CODcr Water Quality Online Automatic Analyzer is widely used in water
pollution monitoring, industrial process water, industrial and municipal wastewater
treatment and other fields.
Quantitative potassium dichromate is added in water samples, and under the condition of
strong acid with silver halide as catalyst, after high temperature, oxygen organic matter and 3+ 6+reducing substances in water will restore Cr back to Cr . Through the photoelectric 3+colorimetric, measuring the generation of Cr , and comparing the measuring value of
sample with the calibration curve of the standard sample value, the COD value can be
obtained.
Technical specifications
Water quality determination of cod-rapid spectrophotometric method
Accuracy:≥40mg/L,<10% of the measured value.
<40mg/L, <5mg/L
0~1000~5000mg/L (customizable)
Digestion Time 3、5、20、30、40、60、80、100 or 120minutes
Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Zero Drift ±5mg/L
Span Drift ±10%
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~45℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional)
Uncertainty
Interface
1: Photoelectric non-contact measurement, high measuring accuracy and high reliability operation
2: Each sampling requires liquid amount < 9 ml, low maintenance cost
3: Integrated digestion / colorimetric module (patent technology), direct measurement after high temperature (170℃)
high pressure airtight digestion, compact structure, complete digestion, high efficiency
4: Using high resolution industrial-grade color touch screen, easy operation, rich information
5: It can access signal of flow meter and PH meter, main interface can real-time display the measured values
6: A multistage administrative access password and screen digital lock, prevent wrong operation
7: It can realize remote control (including start/stop, measurement, calibration, cleaning, etc.)
Product Features
Analysis Principle
Method
Range
Interval
Product Overview
Ammonia-Nitrogen Water Quality Online Automatic AnalyzerWDet-5000
WDet-5000 ammonia-nitrogen water quality online automatic
analyzer uses nessler's reagent colorimetric method. Now it provides
two options, one for direct injection, colorimetric measurement
scheme, namely, direct method, suitable for circumstance of the stable
and clean water quality, such as sewage treatment plant export.
Another kind is distillation of sewage to drive out NH , by using 3
absorbing liquid to absorb NH and colorimetric measurement, apply 3
to the sewage treatment plant entrance, colored water, etc.
It applies to water pollution monitoring, industrial process water,
industrial and municipal wastewater treatment and other fields.
Ammonia nitrogen in water is mainly refers to the ammonia form of 4+NH and NH , when alkali is strong, ammonia nitrogen mainly exists 3
in the form of NH . Directly join the Nessler's reagent in the water 3
samples (or diluted), using spectrophotometer to realize the
measurement of ammonia nitrogen in water samples.
Product Features1: Support direct method and distillation method,
convenient for user selection
2: Photoelectric non-contact measurement, high
measuring accuracy and high reliability operation
3: Patent of circular multi-channel sample dilution
technique, which can realize large dilution ratio
4: Each sampling requires liquid amount < 9 ml, low
maintenance cost
5: United States imported peristaltic pump pipe, in the
case of sampling per hour, pump pipe can be used
normally for more than six months
6: Reagents with special formula and long shelf life
Absorption/ colorimetric tube
LED DetectorMeasurement,sample injection, drainage module
Join the absorption liquid and nessler's A/nessler's B
Absorption/ colorimetric
tube
LED Detector
Join the absorption liquid and nessler's A
Measurement,sample injection, drainage module
Distillation tube
Peristaltic pump
Heater strip
1/8"Fluorine tube 1/8"Fluorine tube
PT100
Product Overview
Analysis Principal
Direct Method Flow Path Distillation Method Flow Path
Technical specifications
Nessler's reagent colorimetric method
±2%F.S./7d
640*480 touch color LCD display
Reagent
Method
Span Drift
Display Screen
A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2
channel) , the maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2
channel) , compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
RS485/RS232/USB interface (optional) Interface
Multirange, 0.05~50mg/L(low), 0.5~300mg/L(high) Range
±2%F.S./7dZero Drift
Self-Checking
Maintenance
Self monitoring leakage, instrument status self-diagnosis
Minimum measurement period 25minutesPeriod
±5%Linearity
±3%F.S.Reproducibility
4000 groups (extensible SD card storage)Data Storage
Working Temp. 5℃~45℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
Interval>6months, every time approx.30minutes
MDet-5000XColorimetric Method Heavy Metal Water Quality Online Analyzer
Heavy metal pollution refers to the environmental pollution caused by
heavy metals or their compounds, which mainly caused by human
factors such as mining, exhaust emissions, sewage irrigation and the
use of heavy metal products. Heavy metal content of the environment
caused by human activities increases and beyond the normal range,
which leads to the deterioration of the environment quality.
Mdet-5000X series heavy metal water quality online analyzer can
detect the heavy metal content in the water quality online,
measurement is accurate, reliable and safe.
Product Overview
Product Features
Metal Measurement Field Key Indicators
Hexavalent Chromium
/Total Chromium
Widely used in monitoring of hexavalent chromium (total chromium) in industrial sewage
treatment plant and industrial process (such as electroplating, metallurgy, printing and
dyeing industry) , etc.
Range:0~2mg/L(expandable)
:±5% Uncertainty
Copper Ions
/ Total Copper
Widely used in monitoring of copper in wastewater produced by the process of the copper
zinc ore mining and smelting, metal processing, machinery manufacturing, steel production
and so on.
Range:0~5mg/L(expandable)
:±5% Uncertainty
Nickel Ions
/Total Nickel
Widely used in monitoring of nickel in waste water produced by mining, smelting, metal
production, metal processing, electroplating, chemical, ceramics and glass, etc.
Range:0~10mg/L(expandable)
:±5% Uncertainty
Arsenic Ion
/Total Arsenic
Widely used in monitoring of arsenic in waste water produced by arsenic metal mining,
smelting, production of glass, pigments, technical and paper with arsenic and arsenic
compounds as raw materials, use of arsenic pesticide.
Range:0~2mg/L(expandable)
:±5% Uncertainty
Mercury Ion
/ Total Mercury
Widely used in monitoring of pollutants containing mercury produced by metal production,
the semiconductor industry, energy-saving lamp production enterprise.
Range:0~0.5mg/L(expandable)
:±5% Uncertainty
Manganese Ion
/ Total Manganese
Widely used in monitoring of pollutants containing manganese produced by manganese ore
mining, smelting, and production of manganese, glass colorant, dye, paint, paint pigment,
matches, soap, synthetic rubber, plastics, pesticides.
Range:0~8mg/L(expandable)
:±5% Uncertainty
Zinc Ions
/ Total Zinc
Widely used in monitoring of industrial waste water containing zinc pollutants produced by
zinc mining, smelting processing, machinery manufacturing and galvanized, instruments
and meters, organic synthesis and papermaking.
Range:0~2mg/L(expandable)
:±5% Uncertainty
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for
long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration
to the situation of actual water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and remind maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm and display
●
●
●
●
●
●
●
●
●
Total Lead Water Quality Online AnalyzerMDet-5000Pb
This instrument adopts the acidic oxidant under high temperature and
high pressure to transform leaded products into lead ion, then the
porphyrin chromogenic reagent and lead ions in alkaline conditions
form orange-yellow complex compound which has a characteristic
absorption at 480 nm. The complex concentration is proportional to the
concentration of Pb ion, and then through the multi-wave colorimetric
of characteristics complex compound by precision spectrometer, the
content of lead in water is accurately measured.
It is widely used in environmental pollution monitoring
(electroplating, battery, metallurgy, printing and dyeing and other
industries), and municipal wastewater monitoring.
Product Overview
Technical specifications
Porphyrin reagent colorimetric method
0.05~5mg/L,higher range can be customized
Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Reproducibility ±5%
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional) Interface
Method
Range
Interval
Uncertainty ±5%
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life..
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of actual
water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and remind maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm and display
●
●
●
●
●
●
●
●
●
Product Features
MDet-5000Hg Total mercury Water Quality Online Analyzer
Mercury atomic vapor has a strong absorption in ultraviolet of 253.7
nm wavelength,mercury vapor concentration is proportional to the
absorption value. Using stannous chloride to restore mercury ofwater
samples into elemental mercury, pump in the air at ambient
temperature, vaporize the mercury, load the cold atomic absorption
mercury measurement instrument, measure the absorption value, map
the concentration peak shape, the total mercury content in the sample
can be obtained.
Surface water, groundwater, drinking water, sewage and industrial
wastewater
Measuring module
Mercury absorption curve
absorbance
Product Overview
Technical Specifications
Cold atomic absorption spectrophotometry
0.002~0.2mg/L
Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Reproducibility ±3%
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional) Interface
Method
Range
Interval
±3%Uncertainty
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life..
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of actual
water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and remind maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm and display
●
●
●
●
●
●
●
●
●
Product Features
Under the condition of weak acid, cyanide of water samples and
chloramine T generate chloramine cyanide, and then react with
isonicotinic acid, after the hydrolysis generate pentene dialdehyde,
finally, together with barbituric acid generate purple blue compounds,
in a certain concentration range, the chroma is proportional to the
concentration of cyanide.
It applies to the cyanide monitoring of surface water, sewage and
industrial wastewater.
WDet-5000CN Cyanide Water Quality Online Analyzer
Product Overview
Technical specifications
Isonicotinic acid - barbituric acid
±5%
0~1mg/L,higher range can be customized
Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Reproducibility ±5%
Reagent A single set of reagents can measure 250 samples
External Interface
Analog Output:1×4-20mA output (expandable to 2 channel) , the
maximum load 500Ω
Analog Input:1×4-20mA input (expandable to 2 channel) ,
compatible with 0-5V input
Relay Output: 4 channel (can be flexible configuration)
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W 220±10%VAC 50Hz ,regardless of the pump ( )
RS485/RS232/USB interface (optional)
Uncertainty
Interface
Method
Range
Interval
High reliability, low maintenance
Core components are imported, high reliability, long lifetime, suitable for long time online monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contact with liquid will be particularly tested to ensure a long service life..
Specially designed flow path to prevent blocking
Accurate measurement, wide application scope
Photoelectric measurement method, accurate sampling , low sample injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of actual
water samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
Safe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and remind maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm and display
●
●
●
●
●
●
●
●
●
Product Features
When fluorine electrode contacts with the test solution containing
fluorine, battery electromotive force E changes with the change of
fluorine ion activity in the solution (comply with the Nernst
equation).When the total ion strength of solution is the fixed value and
enough, it obeys the relation:
1: Design on the principle of single chip solid ion selective electrode,
the electrode is easy to clean
2: Built-in reference electrode, high measurement accuracy
Slope: within the linear range, when the activity of the ions under test
changes an order of magnitude, it causes electrode potential change value
(mV), which called the slope of electrode to a given ion, also called the
slope of E - logai curve. The theoretical value is represented:
S=2.303RT/(NIF)
It is suitable for determination of the fluoride in surface water, ground
water and industrial wastewater (including semiconductor
manufacturing, solar cells and metallurgical).
Method Ion selective electrode method
Range 0~2000~20000mg/L,other range is adjustable
Interval Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
Zero Drift ±5%
Reagent A single set of reagents can measure 250 samples
ExternalInterface
Maintenance <1hour per month
Working Temp. 5℃~40℃
Power 200W(220±10%VAC 50Hz), regardless of the pump
RS485/RS232/USB interface (optional)Interface
Analog Output:1×4-20mA output (expandable to 2 channel),
the maximum load 500Ω
Analog Input: 1×4-20mA input (expandable to 2 channel),
compatible with 0-5V input, optional
Relay Output: 4 channel (can be flexible configuration)
Span Drift
Linearity
Reproducibility
±5%
±5%
±5%
Period 20 minutes
Fluoride Water Quality Online AnalyzerMDet-5000F
Instrument Principle
Applications
Product Features
Technical Specifications
Corresponding range and detection limitof ion selective electrode
-300
-250
-200mV
-[F ]
E=E2.303RT
Flog c
F
Turbidity analyser
Fluorescence dissolved oxygen analyzer
ØWater plant, turbidity monitoring of reservoir, water wells, clear
water reservoir, before and after filtration, sedimentation and
effluent water.
ØIndustrial production process: water quality monitoring of water
circulation in production, circulating water, etc.
ØSewage treatment: water quality monitoring of water inlet and
outlet.
LCD screen and multiple parameters with the screen display
Built-in bubble elimination system, improve the measurement accuracy and
stability
High accuracy, good repeatability, strong anti-interference ability
Using two-point correction method
Simple cleaning maintenance, convenient correction
Field calibration by comparison
A variety of measuring unit form such as NTU, mg/L
Multifarious installation such as immersion flow-through and plug-in
Sensor can be configured with purging device, controlled by the transmitter for
self-cleaning
Fluorescence principle, sensitive reaction, stable and reliable measurement
Special optical coating, no replacement, no electrolyte, no maintenance
No oxygen consumption, no request of flow rate and agitation.
PPM level sensor, suitable for sewage measurement control
Many kinds of signal output such as current, relay, etc
LCD liquid crystal display
Multiple installation, easy maintenance
Long service life, high accuracy and resolution
Note: please call us for specific performance indicators.
ØMunicipal and industrial wastewater treatment, including
adjusting pool, aeration tank, aerobic and anaerobic digestion
pool, water testing, etc.
ØPower plant water treatment, boiler circulating water.
ØWater environment monitoring of rivers, lakes, sea water,
fisheries aquaculture, etc.
Other Water Quality Online Analyzer
Applications
Product Features
Applications
Product Features
Residual chlorine analyzer Conductivity meter PH meter Sludge concentration meter Ultrasonic flowmeter
Applications
l
l
l
l
l
l
l
l
l
Water monitoring
Environmental monitoring station
Municipal water treatment process
Municipal pipe network water quality monitoring
Rural water monitoring
Circulating cooling water
Swimming pool water operation management
Industrial water recycling
Factory aquaculture and other fields
Typical Applications
HANGZHOU ZETIAN TECHNOLOGY CO.,LTD.
Web
Phone: 86-13588711905 86-0571-28322780
Fax: 86-0571-87851772
E-mail: [email protected]: en.zetian-tech.com
Add: Taiheng Mansion, 22 Zhiren Street, Binjiang District, Hangzhou,