Water Quality Management in Rivers. Dissolved Oxygen Depletion.

36
Water Quality Management in Rivers

Transcript of Water Quality Management in Rivers. Dissolved Oxygen Depletion.

Water Quality Management in Rivers

Dissolved Oxygen Depletion

Dissolved Oxygen Depletion

Biochemical Oxygen Demand Measurement

• Take sample of waste; dilute with oxygen saturated water; add nutrients and microorganisms (seed)

• Measure dissolved oxygen (DO) levels over 5 days• Temperature 20° C• In dark (prevents algae from growing)• Final DO concentration must be > 2 mg/L • Need at least 2 mg/L change in DO over 5 days

Example

• A BOD test was conducted in the laboratory using wastewater being dumped into a Lake. The samples are prepared by adding 3.00 mL of wastewater to the 300.0 mL BOD bottles. The bottles are filled to capacity with seeded dilution water.

Example : Raw Data

Time(days)

Dilutedsample

DO (mg/L)

Blank SeededSample DO

(mg/L)0 7.95 8.151 3.75 8.102 3.45 8.053 2.75 8.004 2.15 7.955 1.80 7.90

Example : Calculations

• What is the BOD5 of the sample?

• Plot the BOD with respect to time.

sample diluted

the of ionsconcentrat DO final and initial DO ,DO

(blank)water diluted seeded

the of ionsconcentrat DO final and initial B ,B

volumetotal sample/ volumefactor dilutionPP

P)])(1B(B-)DO[(DOBOD

fi

fi

fifim

Example : Time – Concentration Plot

0

100

200

300

400

500

600

700

0 1 2 3 4 5 6

time (days)

BO

D (

mg

/L)

Modeling BOD as a First-order Reaction

0123456

0 10 20 30time (days)

Co

nc. (m

g/L

)

Organic matter oxidized

Organic matter remaining

Modeling BOD Reactions

• Assume rate of decomposition of organic waste is proportional to the waste that is left in the flask.

demandoxygen uscarbonaceo ultimate theis where

:yieldsequation thisSolving

)(timeconstant rate BOD the

tafter timeleft demandoxygen ofamount where

1-

o

ktot

t

tt

L

e LL

k

L

- kLdt

dL

Ultimate BOD

0123456

0 10 20 30time (days)

Co

nc

. (m

g/L

)

Lt

Lo

Lo- Lt BOD exerted

L remaining

BODt

Ultimate Biochemical Oxygen Demand

Lt = amount of O2 demand left in sample at time, t

Lo = amount of O2 demand left initially (at time 0, no DO demand has been exerted, so BOD = 0)

At any time, Lo = BODt + Lt (that is the amount of DO demand used up and the amount of DO that could be used up eventually)Assuming that DO depletion is first order

BODt = Lo(1 - e-kt)

Example

• If the BOD5 of a waste is 102 mg/L and the BOD20 (corresponds to the ultimate BOD) is 158 mg/L, what is k?

kteL 10tBOD

kteL

0

1 tBOD

ktL

0

1ln tBOD

Example (cont)

t

Lk

0

1ln tBOD

day

mg/L mg/L

5

158102

1ln

k

-1day 21.0k

Biological Oxygen Demand: Temperature Dependence

• Temperature dependence of biochemical oxygen demand As temperature increases, metabolism

increases, utilization of DO also increases

kt = k20T-20

= 1.135 if T is between 4 - 20 oC = 1.056 if T is between 20 - 30

oC

Example

The BOD rate constant, k, was determined empirically to be 0.20 days-1 at 20 oC.

What is k if the temperature of the water increases to 25 oC?

What is k if the temperature of the water decreases to 10 oC?

Example

202525 )056.1(20.0 -1day k

-1day 26.025 k

201010 )135.1(20.0 -1day k

-1day 056.010 k

Nitrogenous Oxygen Demand

• So far we have dealt only with carbonaceous demand (demand to oxidize carbon compounds)

• Many other compounds, such as proteins, consume oxygen

• Mechanism of reactions are different

Nitrogenous Oxygen Demand

• Nitrification (2 step process)2 NH3 + 3O2 2 NO2

- + 2H+ + 2H2O

2 NO2- + O2 2 NO3

-

– Overall reaction:NH3 + 2O2 NO3

- + H+ + H2O

• Theoretical NBOD = N /gO g 4.57 14

16 x 4

oxidized nitrogen of gramsused oxygen of grams

2

Nitrogenous Oxygen Demand

Nitrogenous oxygen demand

• Untreated domestic wastewater

ultimate-CBOD = 250 - 350 mg/Lultimate-NBOD = 70 - 230 mg/L

Total Kjeldahl Nitrogen (TKN) = total concentration of organic and ammonia nitrogen in wastewater: 15 - 50 mg/L as N

Ultimate NBOD 4.57 x TKN

Other Measures of Oxygen Demand

Chemical Oxygen Demand

• Chemical oxygen demand - similar to BOD but is determined by using a strong oxidizing agent to break down chemical (rather than bacteria)

• Still determines the equivalent amount of oxygen that would be consumed

• Value usually about 1.25 times BOD

Water Quality Management in Rivers

Dissolved Oxygen Depletion

Dissolved Oxygen Sag Curve

Mass Balance Approach

• Originally developed by H.W. Streeter and E.B. Phelps in 1925

• River described as “plug-flow reactor”

• Mass balance is simplified by selection of system boundaries

• Oxygen is depleted by BOD exertion

• Oxygen is gained through re-aeration

Steps in Developing the DO Sag Curve

1. Determine the initial conditions

2. Determine the re-aeration rate from stream geometry

3. Determine the de-oxygenation rate from BOD test and stream geometry

4. Calculate the DO deficit as a function of time

5. Calculate the time and deficit at the critical point

Selecting System Boundaries

Initial Mixing

Qr = river flow (m3/s)DOr = DO in river (mg/L)Lr = BOD in river (mg/L)

Qmix = combined flow (m3/s)DO = mixed DO (mg/L)La = mixed BOD (mg/L)

Qw = waste flow (m3/s)DOw = DO in waste (mg/L)Lw = BOD in waste (mg/L)

1. Determine Initial Conditions

a. Initial dissolved oxygen concentration

b. Initial dissolved oxygen deficit

where D = DO deficit (mg/L)

DOs = saturation DO conc. (mg/L)

rw

rrww

QQ

DOQDOQDO

mix

rrwwsa Q

DOQDOQDOD

DODOD s

1. Determine Initial Conditions

DOsat is a function of temperature. Values can be found in Table.

c. Initial ultimate BOD concentration

rw

rrwwa QQ

LQLQL

2. Determine Re-aeration Rate

a. O’Connor-Dobbins correlation

where kr = reaeration coefficient @ 20ºC (day-1)

u = average stream velocity (m/s)

h = average stream depth (m)

b. Correct rate coefficient for stream temperature

where Θ = 1.024

2/3

2/19.3

h

ukr

2020,

Trr kk

Determine the De-oxygenation Rate

a. rate of de-oxygenation = kdLt

where kd = de-oxygenation rate coefficient (day-1)

Lt = ultimate BOD remaining at time (of travel downstream) t

b. If kd (stream) = k (BOD test)

and

tkt

deLL 0

tkd

deLk 0tiondeoxygenta of rate

3. Determine the De-oxygenation Rate

c. However, k = kd only for deep, slow moving streams. For others,

where η = bed activity coefficient (0.1 – 0.6)d. Correct for temperature

where Θ = 1.135 (4-20ºC) or 1.056 (20-30ºC)

h

ukkd

2020,

Trr kk

4. DO as function of time

• Mass balance on moving element

• Solution is

DkLkdt

dDrtd

tka

tktk

dr

adt

rrd eDeekk

LkD

5. Calculate Critical time and DO

ad

dra

d

r

drc Lk

kkD

k

k

kkt 1ln

1

crcrcd tka

tktk

ar

adc eDee

kk

LkD