WATER POTABILIZATIONRO TREATMENT PLANTS

LABEAU TUNISIE - TUNISIE

RO-S SERIES

Page 2: Water Potabilization RO Treatment Plants

SYSTEMES DE PRODUCTION EAU POTABLE60-1000 m3/day (16000-285000GPD)

Système pour la purification del’eau saumâtre jusqu’à 20.000 TDS,

apte à produire de l’eau à usage industriel, potable, l’irrigation et le processus.

ROS machines comprennent:

- Structure autosuffisant - version standard dimension: 3500/6000x1200/1400x1800/1900h.mm. second modèle. Construit de métal galvanisé et peint à haute résistance - Tous le instruments, les jauges, les commandos et les dispositifs d’urgence sont déplacés sur le panneau frontal du système.- Robuste 40” longuer 5µm sédiments multifilter - caisse externe PVC ou AISI316 réalisés.- Pompe à haute pression: multicellulaires verticales (400V) AISI316L réalisé - Le ROS systèmes comprende des modules d’osmose inverse pour la productione entre 60 et 1000m3/hour (16000-285000GPD) second modèle.- Il est possible d’alimenter le système avec de l’eau à haute SDI avec prétraitments spécifiques. - Le contrôle et l’affichage sont réalisées par les Labeau automate électronique PLC dispositifLe dispositif affiche:- L’état du système- Conductivité d’entrée et de sortie - Pression d’entrée- Pression pompe haute pression- Commande automatique de la stand-by et le nettoyage des membranes d’osmose inverse.- Système automatique de dosage pour le produit antitatre.- Système automatique de dosage pour le produit biocide, etc . (second modèl)

Pour le capacité élevée de ce système est très important de l’analyse de l’eau d’alimentation pour le choix du système de prétraitment.Sont disponibles: adoucisseurs d’eau, dechlorine système, automatique système pour l’élimination du fer, de manganèse.

PROCESSUS:Les processus de l’osmose inverse utiles des membranes pour

WATER POTABILIZATION TREATMENT SYSTEM60-1000 m3/day (16000-285000GPD)

For water purification:

removing more than 98% of media and more than 99% of colloids and other organic matter.

THE ROS SYSTEMS:Each ROS systems consist of following stages:- Self carrying Structure - dimension 6000/3500x1400/1200x1400h.mm. in the standard version, built with steel galvanized and painted structure with facility transportation.- All the instrumentation, the pressure gauges, the commandos and the emergency devices are placeed on the frontal panel of the system.- Heavy duty 40” 5µm sediment Multifilter - external case PVC or AISI304- High pressure pump. Stainless stell AISI316L high pressure Up Vertical multistage pump (400V).- ROS Systems include reverse osmosis modules, production is 60-1000m3/hour (16000-285000GPD)It’s possible to feed the system with high SDI water.- Automatic electronic system control display: - System in operation indicator - Conductivity inlet and outlet - Lighted On/Off controls - Pressure inlet- Automatic control of stand-by and cleaning of reverse osmosis membranes.- Automatic dosing system for antiscalant product.For the elevated capacity of this system is very important a water feeding analysis for the right choice of pretreatment system. So high capacity Water softners, Dechlorine and automatic system for the removal of Iron, Manganese and other are available

PROCESS:The RO process uses membranes to remove dissolved solids, organics, pyrogens and bacteria from water.RO also removes sodium, chloride, hardness, fertilizers, insecticides, arsenic, heavy metals and many other contaminants.Most importantly, RO reduces total dissolved solids (TDS).RoPlant standard production includes a simple pretreatment as a sediment and carbon filter and a more detailed as an

ROS SeriEs

Page 3: Water Potabilization RO Treatment Plants

antiscalent feeder for very hard water in high efficiency RO systems. Other pretreatment methods are determined through a water analysis.

SYSTEM CONTROLThe system is controlled by Labeau PLC that verifies every single parameter in order to assure and to verify continuously the operations.

Main Features:- Acustic and visual Alarm - Inlet/outlet pressure - Display of TDS/Conductivity, pH, Temperature C° and % of recovery - Total hour meter - Membranes auto flush system and built-in cleaning system- The equipment is factory tested and sterilized prior to shipment- All components are high quality with FDZ/NSF approval- Mixing valve for adjusting quality of permeate water.

For the elevated capacity of this system is very important a water feeding analysis for the right choice of pretreatment.

eliminer les matières dissoutes dans l’eau, matière organique, les bactéries et les pyrogénes.Osmose inverse élimine également de sodium, chlorure, dureté, engrais, insecticides, l’arsenic, des métaux lourds et plusieurs autres contaminants.Osmose Inverse surtout réduit la TDS total solides dissous.Les modèles standard de la sèrie ROS comprennent un simple pretraitment comme un filtre à sédimentes, un filtre à charbon et une dose unitaire de antitartre.D’autres méthodes de pretraitment sont établis par l’analyse de l’eau entrante.

SYSTEME DE CONTROLELe système est contrôlé par PLC Labeau qui vérifie chaque paramètre afin d’assurer et de vérifier en permanence les opérations.

Caractéristiques principales:- Alarme visuelle et Acustic- CIP - nettoyage intégré du système- Affichage de TDS / conductivité, pH, température ° C et% de

récupération- Total compteur horaire- auto purger le système de membranes et de

nettoyage intégré du système- Le matériel est testé en usine et stérilisé avant l’expédition- Tous les composants sont de haute qualité avec FDZ / NSF- Vanne de mélange pour ajuster la qualité de l’eau de perméat.