Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission...

16
Volume 13 OVER 60 YEARS SERVICE TO SOUTHERN AFRICAN INDUSTRY Johannesburg t (011) 435 1080 f (011) 435 1306 [email protected] Cape Town t (021) 939 9134 f (021) 939 2638 [email protected] Durban t (031) 205 5265 f (031) 205 7913 [email protected] www.nz.co.za AMR WATER MEASUREMENT

Transcript of Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission...

Page 1: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

Volume 13

over 60 years service to southern african industry

Johannesburg

t (011) 435 1080 f (011) 435 1306

[email protected]

Cape Town

t (021) 939 9134 f (021) 939 2638 [email protected]

Durban

t (031) 205 5265 f (031) 205 7913

[email protected]

www.nz.co.za

amr

W a t e r m e a s u r e m e n t

Page 2: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

Mag Meters with GPRS  telemetry operating

in South Africa

With battery powered mag meters you don’t under-bill and don’t give away water for free!

Isoil’s battery powered mag meters have no moving parts so they are extremely reliable. They are not affected by wear, corrosion, debris build-up or catastrophic failure. So there is no

under-reading as with mechanical meters.

• Accuracy: ± 0.4%

• Battery Life: typically 3 to 6 years

• Seamlessly integrate into the WaMSS Water Management Scada

• Certified to: ISO9001; ISO EN17025; OIMLR49 and MID1001.

AMR Automatic Meter Reading Integrated in South Africa

Flow rate and flow totals are saved in the flow meter’s on-board data logger and can be read off the display. The on-board modem sends the information directly to the WaMSS Scada, which compiles reports and automatically emails them to your pc, tablet or cell.

2 N&Z Instrumentation & Control | www.nz.co.za

You always have reliable flow, billing and maintenance

information at your fingertips.

Under-reading Mechanical Meters

Mag Meters at the Isoil

Factory

Page 3: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

Event Log

Water Loss

The WaMSS Scada is a simple-to-use tool for logging, planning and implementation. It delivers continual performance monitoring and trending and automatically emails reports of key performance parameters.

Automatic Graphs and Reports for AMR and Water Demand Management

WaMSS Scada Web Based Made in South Africa

SqL Database with Automatic Export to other Applications

Statistics for "Available Data"Flow Totals Unit Start End TotalPositive Totalizer m³ 724687 817974 93287Negative Totalizer m³ 0 0 0Net m³ 93287

Meter Reading Reports

Flow TrendsDashboard Report for Management Oversight

Line Pressure Trends

3N&Z Instrumentation & Control | www.nz.co.za

Corrosion Potential Monitoring

Reservoir Level Management

time

le

ve

l

Page 4: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

N&Z’s Water Management System Made in South Africa

WaMSS SCADA

Data collection automatic reportingDate & Time Positive 

TotalizerUnit Negative 

TotalizerUnit Flow 

RateUnit Pressure Unit

2014/06/04  00.30 777305.00 m³ 0.00 m³ 311.90 m³/h 22.63 bar2014/06/04  00.45 777384.00 m³ 0.00 m³ 312.90 m³/h 22.72 bar2014/06/04  01.00 777462.00 m³ 0.00 m³ 313.50 m³/h 22.80 bar2014/06/04  01.15 777540.00 m³ 0.00 m³ 313.80 m³/h 22.78 bar2014/06/04  01.30 777619.00 m³ 0.00 m³ 314.00 m³/h 22.75 bar2014/06/04  01.45 777697.00 m³ 0.00 m³ 313.70 m³/h 22.73 bar2014/06/04  02.00 777776.00 m³ 0.00 m³ 314.00 m³/h 22.73 bar2014/06/04  02.15 777854.00 m³ 0.00 m³ 314.00 m³/h 22.75 bar2014/06/04  02.30 777933.00 m³ 0.00 m³ 315.60 m³/h 22.84 bar2014/06/04  02.45 778012.00 m³ 0.00 m³ 315.40 m³/h 22.93 bar2014/06/04  03.00 778091.00 m³ 0.00 m³ 315.30 m³/h 22.98 bar2014/06/04  03.15 778170.00 m³ 0.00 m³ 315.10 m³/h 22.98 bar MAnAger

reportS AutoMAtiCAlly eMAileD1

3 4

5

7 8

10

9

6

11

• Meter Reading

• Flow Totalisation

• Flow Trend

• Line Pressure Trend

• Reservoir Level Trend

• Water Balances

• Water Loss Reports

• Battery Power

• Antenna Power

1 Isoil battery powered magnetic flow meter with built-in GPRS data transmission.

2 Mechanical flow meter.

3 Pulses from mechanical flow meters.

4 Smart loggers with built-in GPRS data transmission for: • Mechanical Flow Meters • Line Pressure • Reservoir Level • Analyzers • Other Sensors.

5 Data transmission via GPRS on the GSM network.

6 WaMSS Scada System. Web based.

7 Data from field sensors are imported into an SqL database.

8 Reports are automatically compiled and emailed according to user’s schedule.

9 Management has key information at their fingertips and can compile adhoc reports.

10 Users receive regular alarms and regular reports so they can take action quickly.

11 Data Relay to other applications.

2

4 N&Z Instrumentation & Control | www.nz.co.za

Page 5: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

(L) Unauthorised Use(M) Metering Inaccuracies

(O) Leaks on Services

(A) System Input Volume

(C) Water Losses

(B) Authorised Consumption

(D) Billed Authorised

Consumption

(H) Billed Metered Use

(I) Billed Unmetered Use

(E) Unbilled Authorised

Consumption

(J) Unbilled Metered Use

(Q) Revenue Water - 47%

(R) Non-Revenue Water - 53%(K) Unbilled Unmetered Use

(F) Apparent

(G) Real Losses

(N) Leaks on Transmission and/or distribution mains

(P) Storage Tank Leaks and Overflows 83m²

NO DROP

3

WaMSS Scada – Produces Graphs and Reports for your Water Management

The WaMSS Scada is a simple to use tool in the logging phase, planning phase and implementation. It enables you to continually monitor and trend your performance and automatically compiles reports featuring your key performance parameters.

International Water Association model

You need to know how the system performance changes over time.

� ��Water�BalanceN&Z’s WaMSS system produces Water Balance Diagrams based on the IWA model. Metered flows are sent from our battery powered mag meters or from existing mechanical meters fitted with our “Smart” loggers. .

The flow measurements are automatically processed by the Water Balance model. The model also processes your estimates of “un-billed, un-metered use”, “leakage on transmission and distribution mains” etc., as a percentage of the System Input or as absolute values.

These diagrams are produced automatically for the time window that you choose and are automatically e-mailed.

WaMSS Scada Water Balance as per IWA guidelines

5N&Z Instrumentation & Control | www.nz.co.za

� ��Water�Balance�TrendThe WaMSS produces a water balance trend on a daily, weekly, monthly or yearly basis where these critical performance indexes are automatically graphed.

Page 6: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

• Battery-powered • GPRS data transmission • Seamless integrations into WaMSS Scada • South African manufactured

WaMSS loggers accept pulses from flow meters, pressure sensors and 4-20mA inputs from any sensors, and logs the data. These data files are sent automatically by GPRS to the web-based WaMSS Scada. So you can easily incorporate flow meters into an AMR system or log parameters such as level, pressure, pH, conductivity, etc. into a simple-to-use, plug and play Scada.

A number of models are available to suit different applications. And being locally designed and manufactured, we provide on-the-spot support.

WaMSS ‘Smart’ Loggers Made in South Africa

WaMSS Loggers are widely used for flow or level logging or as a part of an AMR system.

WaMSS loggers regularly measure their current

location. Its GPS co-ords are available on the Scada

� ��Base�Specifications• Pulse inputs: Automatically detects whether the sensor is active (supplies voltage) maximum 10Hz; or

passive (voltage supplied by logger) maximum 30Hz. Selectable ‘relay debounce’ function.

• Analogue inputs: 4-20mA, selectable active (sensor supplies power) or passive (logger supplies power, pulsed at the sampling window.)

• Pressure sensors for pressure or level measurement.

• Approximate GPS co-ordinates.

• Power: High quality lithium batteries. These typically have three to six years life depending on configuration.

- External power facility: 9-24 VDC.

- Automatic switchover to external power i.e. battery backup.

• Housing: IP68 or IP67.

• Logged data sent by built-in GSM module via GPRS as .csv files attached to an email. Integrates seamlessly with the WaMSS Scada or other software..

6 N&Z Instrumentation & Control | www.nz.co.za

Page 7: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

N&Z provides a complete service of flow logging, flow surveys, flow meter testing and pump testing. We operate throughout South Africa and measure most liquids from potable water and raw water through to effluent and slurries.

Flow Logging; Flow Surveys; Flow Meter Testing & Pump Testing

� ��Flow�Logging�(Leak Detection)

Flow logging is a very powerful tool which reveals flow characteristics, giving valuable information on the probability of existing leaks, pipe bursts, system design, operations and pumping strategy.

Flow is logged by “Smart” battery powered flow meters with built-in GPRS telemetry; alternatively we fit a “smart” logger to an existing meter or temporary portable meter. The data is sent by GPRS to the WaMSS Scada which automatically emails flow trends. The flow trends reveal flow variations and alert you to unusual operations.

An unexpected shift in the Flow trend will often alert you to a burst pipe

� ���Flow�Meter�Testing�and�Pump�Testing

Call N&Z out for flow meter testing and pump testing. We use a portable Fuji Ultrasonic flow meter for clear liquids and a Greyline Doppler meter for effluent and slurries.

For a quick and inexpensive spot Flow Rate test we monitor the output of your existing flow meter or pump.

A more thorough test is performed over a prolonged period using Flow Totalisation.

7N&Z Instrumentation & Control | www.nz.co.za

Flow Trend

Page 8: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

���Reservoir�level�measurement�and�management�is�an�essential�part�of�reliable�water�delivery�to�users

“Having water in the reservoir is like having money in the bank” - But equally an over flowing reservoir is a waste of money!

The most reliable way to measure water level is a pressure sensor connected to a pressure tapping on the bottom of the tank, or submerged in the water.

The pressure sensor connects to the Isoil battery powered magnetic flow meter or WaMSlog Smart Logger. The level measurement is sent by GPRS to the WaMSS Scada. The Scada trends the reservoir level, as well as water In-flow and Out-flow.

The reservoirs on the Scada display are grouped by region, or by those which are in alarm, e.g. too full (overflowing) or too empty (too low).

Pressure sensor for water level measurement

8

Reservoir Level Management

N&Z Instrumentation & Control | www.nz.co.za

Page 9: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

���Isoil�is�an�Italian�specialist�magnetic�flow�meter�manufacturer�focusing�on�the�water�industry.�

Their most successful model is the battery-powered full bore flow meter suitable for line sizes up to 1,200mm! It has major accuracy and reliability advantages over mechanical meters and is used widely in water distribution and management applications. The optional battery powered GPRS module sends flow measurements directly to our Scada system giving a complete AMR solution (Automatic Meter Reading).The Isoil insertion meter costs less than the full bore model and can be installed while the pipe line is under pressure with no interruption to the flow. It is available in battery-power GPRS version, and has a typical repeatability of ±0.5%.Isoil also supply pressure sensors and a Cathodic Potential Module which are fully compatible with their battery powered converter. A further unique advantage is a low flow calibration which is independent of the standard calibration.Isoil’s unique coil technology makes their sensor extremely sensitive with the result that Isoil is now widely used for both loop powered and battery powered applications.

2

9

Isoil Magnetic Flow Meters

1

1

N&Z Instrumentation & Control | www.nz.co.za

3

4

1 Full bore mag flow meter with battery powered converter and AMR option

2 Full bore flow meters at Isoil factory.

3 Supervisory monitoring of pipe Cathodic Potential

4 Insertion flow meter with pressure sensor and battery-powered converter.

5 Every Isoil mag meter is wet calibrated on an ISO17025 approved flow rig

5

Page 10: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

��How�it�works�–�Non-contact,�Non-invasiveUltrasonic flow meters do not come into contact with the fluid at all. They are easy to install, commission and maintain. Installation requires no plant downtime. Ideal for both portable and fixed applications, line size has little influence on price.

With no obstruction to flow, no pressure drop and no maintenance, the life-cycle cost of ownership is extremely low.

• Portable flow meters are widely used for spot measurements or for checking the accuracy of existing flow meters.

• Fixed meters are easy to install as they do not require any plant downtime or changes to existing piping.

���Greyline�Doppler�Flow�Meter�For Liquids with air bubbles or suspended solids or slurries.

10

Ultrasonic Flow Meters – Clamp-on, non-contact

Ultrasonic pulses are propagated between sensors mounted on the outside of the pipe. The ‘time of flight’ of these pulses is used to calculate liquid flow rate

���Fuji�Time�of�Flight�Flow�Meter�Precise and ideal for clear liquids.

Sensor Sensor

N&Z Instrumentation & Control | www.nz.co.za

Bubbles or solids reflect sound

Sound waves transmitted from the sensor

Sound waves are reflected back to the sensor

Page 11: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

��Fuji’s�fixed�ultrasonic�flow�meterCost effective permanent installationsFlow data, system parameters and diagnostics are shown on the 16 letter, 2 line LCD display; flow rate is transmitted by a 4-20mA output and flow volume by pulses; the RS-232C interface gives efficient connection to PCs, networks, telemetry, etc.

��VerificationFuji ultrasonic meters have in-situ verification for full confidence in measurement accuracy.

��Portaflow�Hand-Held Flow MeterThe Portaflow has a large, clear LCD display for flow rate, totalised flow in both directions, site details and diagnostics. Flow data can also be downloaded onto a PC to produce reports. There are hundreds of Fuji Portaflows operating in South Africa.

Calibrated at Eskom’s SANAS-approved laboratory to an accuracy of +0.32% RMS (certificate U08UC9040-1)

Calibrated at Eskom’s SANAS-approved laboratory to an accuracy of +0.30% RMS (certificate U08UC9065-1)

��Used�for�Clear�LiquidsFuji is a pioneer in portable ultrasonic flow metering. Their many years of experience gives you a meter which works in extreme applications. And the built-in verification function which Fuji pioneered gives you full confidence in your measurement accuracy. Normal operating accuracies are between ±0.5% to ±1% of readings. Accuracies of up to ±0.23% can be achieved where the pipe is sound and the dimensions are precisely known. The meter is suitable for pipes from 13 to 6,000mm.

11

Fuji’s Clamp-on Ultrasonic Time-of-Flight Flow Meters

N&Z Instrumentation & Control | www.nz.co.za

Page 12: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

12

��For�Liquids�with�air�bubbles�or�suspended�solids�or�slurriesGreyline’s non-intrusive flow meters measure flow from outside the pipe with a strap-on sensor. They are ideal for aerated liquids, waste water, slurries and effluent.

Suitable for pipes from 25mm to 4,500mm in diameter and flow velocities from 0.08 to 12.2m/sec, accuracy is typically ±2%.

For best operation the liquid should have solids or bubbles with a minimum size of 100 microns and minimum solids concentration of 75ppm.

Doppler Clamp-on Ultrasonic Flow Meters

N&Z Instrumentation & Control | www.nz.co.za

���Greyline�Hand-Held��Doppler�Flow�

���Greyline�Fixed�Doppler�Flow�Meter

Page 13: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

��How�it�works• Level is measured by an ultrasonic sensor which can be mounted at the bottom of the channel, externally

above the channel, or by a pressure sensor in the channel.

• Flow velocity is measured by a submerged Doppler sensor which is ideal for most surface water, waste water and effluent applications, or alternatively by a non-contract laser sensor which is ideal for waste water and effluent.

• These measurements, combined with the stored data of the geometry of the channel give volumetric flow rate.

13

��Measure�flow�in�part-filled�pipes�and�open�channels�without�weirs�or�flumesWeirs and flumes frequently erode or silt up making readings misleading. And the Manning formula model is strongly affected by changes in the channel conditions and down-stream obstructions and can lead to dramatic over-reading.

Area velocity flow meters are the ideal solution for measuring flow in partially filled pipes and open channels.

Open Channel Flow Meters

N&Z Instrumentation & Control | www.nz.co.za

Page 14: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

14

Water Quality Monitors

ATI has been a leading manufacturer of reliable water quality monitors for more than two decades. There is an extensive installed base of ATI monitors at Water Boards and municipalities in South Africa, supplied by N&Z and with strong support from the ATI factory.

ATI is also a pioneer in remote water quality monitoring using “Smart” sensors in a multi-parameter system which also had the benefit of minimum water consumption.

��Potable�Water�ApplicationsATI monitors have a proven track record in South Africa for pH, conductivity, turbidity, chlorine and ammonia measurement.

Measure Residual Chlorine Without ReagentsA major advantageof ATI’s chlorine monitor is that usually you do not require pre-sample treatment. This means you get dependable measurements without expensive chemicals or time-consuming maintenance. Sensors are available for Free Chlorine and Chloramine (combined chlorine).

AmmoniaATI has made a breakthrough in on-line moitoring with their Model Q46 which is easier to operate and less expensive that standard systems but with a higher degree of reliability – and at a lower cost.

The Q46 measures Total Ammonia and Monochloramine concentrations; the Free Ammonia concentration is derived from these values.

The simple chemical system uses inexpensive reagents and the fast response time (90% in 3 minutes) makes the system suitable for online control.

��Waste�Water�ApplicationsDissolved Oxygen - Auto-clean OptionATI’s patented AutoClean Air Wash system is very effective in wastewater and effluent where rapid sensor fouling is a major problem. This system blasts the surface of the sensing membrane, giving many months of maintenance-free operation.

Calibration is quick and accurate using ambient air and barometric pressure as references.

Numerous systems have been operating in South Africa since 1997.

N&Z Instrumentation & Control | www.nz.co.za

Parameters Measured by ATI Water Monitors

Ammonia ChlorineChlorine Dioxide

ConductivityDissolved Oxygen

Hydrogen Peroxide

Ozone

Peracetic Acid Permanganate Ph/Orp Sulphide SulphiteSuspended

SolidsTurbidity

Page 15: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

15

Liquid Monitors

���Automatic�Water�Quality�Monitoring�at�Remote�SitesThe MetriNet system is ideal for measuring water quality at remote sites and transmitting the data to our WaMSS Scada or other software. MetriNet measures up to 8 parameters; each parameter is measured by its own node which can be calibrated in your laboratory and simply plug into the MetriNet on site. The system has minimal service and water requirements. The Scada provides a complete monitoring and alarming facility and automatic data transfer to other software systems.

���Pump�Station�Level�Controller�Package��(with Ultrasonic Level Sensor and backup Pressure Level Sensor)

The stand-alone Greyline PSL controls your pump station level intelligently. It has 6 built-in relays which control your pumps and valves.

The Greyline system includes a non-contact ultrasonic level sensor and a back-up pressure level sensor. If the controller loses signal from the ultrasonic sensor, for example due to foam on the water surface, the back-up pressure sensor automatically kicks in.

The Greyline PSL brings new reliability to pump station level control in one integrated  package.

Together with N&Z’s Smart loggers and WaMSS Scada the PSL provides a robust “local control and remote supervision” system.

MetriNet MeasuresFree Chlorine Total Chlorine Chlorine Dioxide pH

ORP Dissolved Oxygen Dissolved Ozone Conductivity

Fluoride Turbidity Peracetic Acid Hydrogen Peroxide

��Sludge�Level�MeasurementSludge Level Detection for clarifiers and thickeners.Measuring sludge blankets in clarifiers or thickeners is challenging, but the EcoSmart has proved to be very reliable in South African applications.

The Smart sensor is mounted under water and an ultrasonic beam gives continuous sludge level measurements. The optional self-cleaning wiper removes bubbles, slime and other material accumulations from the sensor to provide reliable operation in hostile environments.

N&Z Instrumentation & Control | www.nz.co.za

Page 16: Water measurement2014/06/04 00.30 777305.00m³ 0.00m³ 311.90m³/h 22.63 bar ... 5 Data transmission via GPRS on the GSM network. 6 WaMSS Scada System. Web based. ... pipe bursts,

N&Z has been supplying leading instrumentation and control products to Southern African industry for more than 60 years.

We represent a portfolio of renowned manufacturers and can therefore supply most of your process measurement, control, telemetry and analysis needs.

Full support from engineering, specication, supply, installation, commissioning, service, repair and onsite flow surveys is provided for all industries.

Our Mission���To efficiently provide our customers with excellent equipment, services,

and support.

���To be the preferred solution supplier for industry’s measurement and control applications.

���To have a long-term, mutually beneficial relationship with our customers, employees, suppliers and shareholders.

Volume 13

Johannesburg

t (011) 435 1080 f (011) 435 1306

[email protected]

Cape Town

t (021) 939 9134 f (021) 939 2638 [email protected]

Durban

t (031) 205 5265 f (031) 205 7913

[email protected]