Wall Mounted Ceiling Cassette Ceiling Convertible …...PCXF14 PRODUCT SYSTEM Chilled Water Wall...
Transcript of Wall Mounted Ceiling Cassette Ceiling Convertible …...PCXF14 PRODUCT SYSTEM Chilled Water Wall...
PCXF14
PRODUCT SYSTEMChilled Water
Wall Mounted
Ceiling Cassette
Ceiling Convertible
Fan Coil UnitProduct Catalogue
Ducted
Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.
@2014-1
Cooling Capacity
FWW-L
FWF-C
FWK-E/ FWKE-E/
FWKE-EH
FWE-E
FWC-C
FUD-B
0 5 10 15 20
kW
25 30 35 40
Products Overview
2 / 4 / 5
5 / 6 / 8 / 9 / 11 / 13
5 / 6 / 7 / 8 / 10 / 12
20 / 25 / 30 / 40
Contents
02
Wall Mounted Type
05
Ceiling Cassette Type
08 12
16
Ceiling Convertible Type
Ceiling Concealed Type
Ducted Blower Type
20
24
Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. All specifications are subjected to change by the manufacturer without prior notice.
* With Brushless DC Motor
2 / 3 / 4 / 5 / 6
3 / 4 / 6 / 7 / 9 / 11 / 12 / 14 / 16
32
FWW-L Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A (Option)
› Comfortable Air Flow & Lower Sound Level› Stylish Flat-Panel › Indoor Quiet Mode› Turbo Mode› Uniform Air Distribution› Easy Maintenance
› NIM-Able› Sleep Function For Cool And Heat Mode› Auto Restart With Last-State-Memory› Valve & Valveless Control Options› Self Diagnosis Features› Compact & Easy To Use Wireless Remote Controller
Wall Mounted TypeComfortble Air Flow & Lower Sound LevelUser given more choice on preferable fan speed, quiet mode or automatic setting. With the introduction of SCR indoor fan motor, a step-less change of fan speed results in smooth air flow and unnoticeable sound level change during fan speed change.
Stylish Flat-PanelIdeal blend of style and function.• The front panel is designed for contemporary style without
compromising on function.• Air intake area is designed to ensure smooth air flow profile for
better sound quality and optimized volume.
Indoor Quiet ModeMore quiet room environment.• With up to five selectable fan speeds, users are given more
choices. By selecting Quiet mode, the sound pressure level is reduced down to an unobstrusive 24 dBA.
• To quickly cool down the room, Turbo model can be selected for maximum cooling power and highest airflow.
Sleep function for Cool and Heat modeOnce activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment.
Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A (Option)
20Rustling
Of Leaves30
Pendulum OfA Wall Clock
40Library
50Normal Office (dB)
24dBA Is So Quiet You Can Even Hear Whispers
24dBAfor
FWWM-L
FanSpeed
H
Low
TurboSL L M
High
Compact & Easy To Use Wireless Remote ControllerCompact and user friendly wireless remote controller BRC52A offers:
• Real Time Clock• "Glow in the dark" ON/OFF Button• Low, Medium, High fan speed options• ON Timer Setting
Heating mode*
Cooling
Hour
s
Tem
pera
ture
Sleep Set On
+0.5˚C
0 1/21
2
+0.5˚C+1˚C
Cooling mode
Heating
Hour
s
Tem
pera
ture
Sleep Set On
-1˚C
-2˚C
-3˚C
0 1/2 12
T set
T room
Start 20min 30min
Power Failure Power Returns
E2 PROME2 PROM
Setting stored before power failure.
RestartStopOperation
Auto Restart with Last-State-MemoryIn case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed.
Uniform Air DistributionAutomated air swing ensures conditioned air distributed evenly.
Easy MaintenanceAir intake grill is easily detachable to be cleaned with water.
Self Diagnosis FeaturesThis feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights.
Turbo ModeTURBO function is available in COOL and HEAT modes only. Once it is activated, the air-conditioner will run into full power with indoor fan running at MAX speed for 20 minutes. This enables the set temperature to be achieved faster. If TURBO and SLEEP are activated at the same time, the SLEEP mode timer will be reset, it will resume after TURBO function is cleared.
54
Specification for Wall Mounted Type ~ 50HZ
FWW02L FWW03L FWW04L FWW05L FWW06L
Btu/h 8300 9200 11300 15500 18000W 2430 2700 3310 4540 5280
Btu/h 6300 6900 9000 11700 14000W 1850 2020 2640 3430 4100
Btu/h 11000 12000 15000 20500 25000W 3220 3520 4400 6010 7330W 31 32 42 57 72A 0.20 0.20 0.21 0.30 0.34
V/Ph/Hz
CFM 260 280 370 510 620CFM 230 250 320 450 520CFMCFM
200180
220190
260240
390360
460440
USGPM 1.85 2.03 2.51 3.43 4.01litres/min 7.00 7.68 9.50 13.00 15.18
kPa 34.0 24.0 31.0 30.0 36.0kPa 29.0 20.0 25.0 27.0 33.0kPam/s 0.68 0.74 0.97 0.83 1.01dBA 34 / 29 / 25 / 24 35 / 30 / 25 / 24 42 / 39 / 32 / 29 42 / 38 / 34 / 32 46 / 42 / 39 / 37
H X W X D mmH X W X D mm
kgmmmm
HIGH RPM 1030 1050 1310 1035 1250MEDIUM RPM 890 910 1150 920 1070LOW RPM 760 780 955 825 970
HIGH W 31 32 42 57 72MEDIUM W 29 31 37 50 68LOW W 25 29 33 43 60HIGH A 0.20 0.20 0.21 0.30 0.34MEDIUM A 0.19 0.20 0.20 0.29 0.32LOW A 0.17 0.19 0.19 0.26 0.31
A 0.40 0.40 0.40 0.30 0.43W 18 18 18 26 30
mm
m² 0.18 0.18 0.18 0.29 0.29
litre 0.52 0.58 0.58 0.95 0.95
pc
COLOUR
FAN
RATEDINPUT POWER
310 X 1065 X 224
14
COIL
TUBEMATERIAL
QUANTITY
1608
288 X 800 X 206344 x 874 x 274
9386 X 1136 X 314
CASING WHITE
AIR QUALITY
MOTOR OUTPUT
IP20 IP44
WATER VOLUMEROW 2
FILTERTYPE WASHABLE SARANET FILTER
COPPERDIAMETER 7.00
FIN MATERIAL ALUMINIUMFACE AREA
2
E
POLES 4
TYPE CROSS FLOW FANDRIVE DIRECT
RATEDRUNNINGCURRENT
FAN SPEED
FAN MOTOR
TYPE INDUCTIONINDEX OF PROTECTION (IP)INSULATION GRADE
PACKING DIMENSION UNIT WEIGHT CONDENSATE DRAIN SIZE 19.05PIPE CONNECTION
MEDIUMLOWQUIET
NOMINAL WATER FLOW RATE
12.70
HEAD LOSS (COOLING)HEAD LOSS (HEATING) : 50˚CMAX. WORKING PRESSURESURFACE AIR VELOCITYSOUND PRESSURE LEVEL (H/M/L/Q)UNIT DIMENSION
220-240 / 1 / 50
REFRIGERANT TYPE N/A
INDO
OR
UNIT
CONTROLAIR DISCHARGE AUTOMATIC LOUVER (UP & DOWN)OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
STARTING CURRENT
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENT
POWER SOURCE
AIR FLOW
HIGH
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
FWF-C
Wireless Remote ControllerBRC52A
Wired Remote ControllerBRC51A
› Compact Design› Fresh Air Intake› Stylish & Slim Panel› Built In High Head Drain Oump & Water Flow Switch› 4 Way Air Discharge & Air Swing› Valve Or Valveless Control Options
› Branch Duct Connection› Sleep Function For Cool & Heat Mode› Auto Restart With Last-State-Memory› NIM-Able› Self Diagnosis Features› Choices Of Wired Or Withless Remote Controller
Ceiling Cassette Compact Type (600x600)
76
Compact DesignCeiling Cassette C Series body dimension is only 570 mm x 570 mm which can easily fits into a 600 mm ceiling grid.
Fresh Air Intake• Knock out hole is available at the unit.• Installation & accessories need to be field supplied & installed.• Keep the introduction of fresh air intake within 20% of the total
air flow. Also provide a chamber and use a booster fan.
Choices Of Wired Or Wireless Remote ControllerCompact and user friendly wireless BRC52A and wired BRC51A remote controller offer :• Real Time Clock• "Glow in the dark" ON/OFF Button• Low, Medium, High fan speed options• ON Timer Setting
Stylish & Slim PanelThe slim panel can be blended easily into decoration and interior design.
Self Diagnosis FeaturesThis feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights.
Sleep Function For Cool And Heat ModeOnce activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment.
Heating mode*
Cooling
Hour
s
Tem
pera
ture
Sleep Set On
+0.5˚C
0 1/21
2
+0.5˚C+1˚C
Cooling mode
Heating
Hour
s
Tem
pera
ture
Sleep Set On
-1˚C
-2˚C
-3˚C
0 1/2 12
600mm600mm
570mm 570mm
Duct flange (With insulation material)
Intake duct (Field supplied and installed)
Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A
Power Failure Power Returns
E2 PROME2 PROM
Setting stored before power failure.
RestartStopOperation
Auto Restart With Last-State-MemoryIn case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed.
Branch Duct ConnectionImproves air flow distribution when there is an obstruction. It allows for air conditioning of two rooms simultaneously.
4 Way Air Discharge & Air SwingIt comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.
Built In High Head Drain Pump & Water Flow SwitchThe unit comes with a 700 mm built-in high head drain pump. A safety float is incorporated int he drain pump to monitor its water level.
700mm
Valve Or Valveless Control OptionsThe design is flexible enough to allow for either valve or valveless control installation.
Branch duct chamberDischarge duct
Room 1 Room 2
Wall
Specification for Ceiling Cassette Compact Type ~ 50Hz
FWF02C FWF04C FWF05C
Btu/h 8500 14000 15500W 2490 4100 4540
Btu/h 6500 10000 11500W 1910 2930 3370
Btu/h 12000 16000 18000W 3520 4690 5280W 63 64 79A 0.28 0.28 0.35
V/Ph/Hz
CFM 380 400 440CFM 290 310 330CFM 230 220 280
USGPM 2.03 3.43 3.57litres/min 7.68 12.98 13.51
kPa 19.3 26.9 28.8kPa 16.8 23.9 26.5kPam/s 0.75 0.76 0.83dBA 42 / 35 / 29 45 / 38 / 30 48 / 40 / 36
H X W X D mmH X W X D mm
kg 15 + 3 17 + 3 17 + 3mmmm
HIGH RPM 725 810 900MEDIUM RPM 565 630 700LOW RPM 460 480 610
HIGH W 63 64 79MEDIUM W 51 58 73LOW W 46 52 69HIGH A 0.28 0.28 0.35MEDIUM A 0.23 0.25 0.32LOW A 0.21 0.24 0.31
A 0.32 0.30 0.47W 17 23 28
mm
m² 0.24 0.25 0.251 2 2
litre 0.43 0.83 0.83
pc
COLOUR
DIRECT
19.0519.05
TYPE TURBO FAN
250 X 570 X 570 (295 X 640 X 640)
CASING
B
WATER VOLUME
AIR QUALITY
FIN MATERIAL
220-240 / 1 / 50
LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL4 WAY AUTOMATIC LOUVER (UP & DOWN)
LIGHT GREY1
WASHABLE SARANET FILTER
ALUMINIUM
N/A
316 X 630 X 630 (126 X 700 X 726)
1608
FACE AREAROW
7.00
FILTERTYPEQUANTITY
TUBEMATERIAL
INSULATION GRADE
CONDENSATE DRAIN SIZE
POLES 6COPPER
DIAMETER
COIL
IP20
PIPE CONNECTION
INDUCTION
HEAD LOSS (COOLING)HEAD LOSS (HEATING) : 50°CMAX. WORKING PRESSURESURFACE AIR VELOCITYSOUND PRESSURE LEVEL (H/M/L)UNIT DIMENSION - ( ) WITH PANEL
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWER
AIR FLOWHIGH MEDIUMLOW
POWER SOURCE
NOMINAL RUNNING CURRENT
INDO
OR
UNIT
CONTROLAIR DISCHARGEOPERATION
NOMINAL WATER FLOW RATE
REFRIGERANT TYPE
PACKING DIMENSION - ( ) PANELUNIT WEIGHT (UNIT + PANEL)
MOTOR OUTPUT
FAN SPEEDFAN
RATEDINPUT POWER
RATEDRUNNINGCURRENT
STARTING CURRENT
DRIVE
FAN MOTOR
TYPEINDEX OF PROTECTION (IP)
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
8
FWK-E
Wireless Remote ControllerBRC52A
Wired Remote ControllerBRC51A
› Multi Comfort - 3 Air Swing Pattern Control› Fresh Air Intake› Optimum Air Discharge› Superior Sound Level› Branch Duct Connection› Low Height Design› Built In High Head Drain Pump & Water Flow Switch› Modern & Elegant Panel
› Low water Pressure Drop› Self Diagnosis Features› NIM-Able› Valve Or Valveless Control Options› Sleep Function For Cool & Heat Mode› Auto Restart With Last-State-Memory› Choices Of Wired Or Wireless Remote Controller
Ceiling Cassette Type (900x900)Multi Comfort - 3 Air Swing Pattern ControlTo increase the comfort level of the air conditioned area of FWK-E series, the system had been built in with three different type of air flow pattern to suit different requirement.* The default setting is pattern 1. The air swing pattern can be
selected via wireless remonote control.
Fresh Air Intake• Knock out hole is available at the unit.• Installation & accessories need to be field supplied & installed.• Keep the introduction of fresh air intake within 20% of the total
air flow. Also provide a chamber and use a booster fan.
Duct flange (With insulation material)
Intake duct (Field supplied and installed)
Branch Duct ConnectionImproves air flow distribution when there is an obstruction. It allows for air conditioning of two rooms simultaneously.
Optimum Air DischargeCombining 4 ways air discharge and large discharge area on each side, Ceiling Cassette promote even air distribution. The additional feature of automatic air swing helps to distribute the conditioned air more evenly to every corner of the room.
Low Height DesignUnit height as low as 265mm for installation convenience.
Superior Sound LevelWith the adapted technology from Daikin turbo fan, Ceiling Cassette series is able to achieve exceptional low noise.With up to 4 selected fan speeds, users are given more choices. By selecting the Quiet mode, the sound pressure level can be as low as 23dBA.
Branch duct chamberDischarge duct
Room 1 Room 2
Wall
10˚ 10˚
65˚65˚
Standard SettingLouver is set to swing at the maximum angle for gentle drafts.
10˚ 10˚
40˚40˚
Pattern 1
Pattern 2
Pattern 330˚
65˚
30˚
65˚
Draft Prevention SettingWith the aid of Coanda effect, direct draft which may lead to discomfort can be avoided.
Soil Prevention SettingEven distribution of cooling whilst ensuring ceiling to bekept spotless.
Longitudinal vortices generated along serration edges accelerate mixing turbulence which reduces vortex shedding noise.
265mm 350mm
9
1110
NIM-AbleAble to communicate with the versatile NIM networking control module and offers the oppurtunity of one centralized control for a system of multiple indoor units in a building.
Choices Of Wired Or Wireless Remote ControllerCompact and user friendly wireless BRC52A and wired BRC51Aremote controller offer :• Real Time Clock• "Glow in the dark" ON/OFF Button• Low, Medium, High fan speed options• ON Timer Setting
Self Diagnosis FeaturesThis feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights.
Low Water Pressure DropAlso commonly known as low head loss actually helps to increase the system efficiency.
Heating mode*
Cooling
Hour
s
Tem
pera
ture
Sleep Set On
+0.5˚C
0 1/21
2
+0.5˚C+1˚C
Cooling mode
Heating
Hour
s
Tem
pera
ture
Sleep Set On
-1˚C
-2˚C
-3˚C
0 1/2 12
Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A
Power Failure Power Returns
E2 PROME2 PROM
Setting stored before power failure.
RestartStopOperation
Auto Restart With Last-State-MemoryIn case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed.
Modern & Elegant PanelIt is designed with unique "round" side contour and new LED light location. The rotateable intake grill promotes uniform installation as well.
Built In High Head Drain Pump &Water Flow SwitchThe unit comes with a 700mm built-in high head drain pump. A safety float is incorporated int he drain pump to monitor its water level.
700mm
Valve Or Valveless Control OptionsThe design is flexible enough to allow for either valve or valveless control installation.
Sleep Function For Cool And Heat ModeOnce activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment.
Specification for Ceiling Cassette Type ~ 50HzFWK06E FWK08E FWK09E FWK11E FWK13E
Btu/h 21000 25000 30000 38000 43000W 6150 7330 8790 11140 12600
Btu/h 16700 19200 22300 27400 31000W 4890 5630 6540 8030 9090
Btu/h 28000 33600 38300 45500 52000W 8210 9850 11230 13340 15240W 95 126 167 186 227A 0.44 0.55 0.74 0.85 1.03
V/Ph/Hz
CFM 750 860 890 1000 1140CFM 620 700 720 840 1000CFM 480 540 570 680 840CFM 320 380 420 540 700
USGPM 4.71 5.59 6.69 8.45 9.60litres/min 17.83 21.17 25.29 31.94 36.29
kPa 20 37 22 44 53kPa 19 33 19 38 47kPam/s 0.91 1.04 1.14 1.03 1.17dBA 42/38/32/23 46/42/35/27 48/43/38/30 50/47/43/33 52/49/45/39
H X W X D mmH X W X D mm
kg 26 + 4 26 + 4 28 + 4 32 + 4 32 + 4mmmm
HIGH RPM 530 600 660 710 800MEDIUM RPM 450 500 550 610 710LOW RPM 360 400 450 510 610
HIGH W 95 126 167 186 227MEDIUM W 79 103 109 151 176LOW W 67 89 86 118 144HIGH A 0.44 0.55 0.74 0.85 1.03MEDIUM A 0.40 0.45 0.49 0.71 0.82LOW A 0.36 0.39 0.39 0.57 0.69
0.44 0.71 0.89 1.02 1.28AW 30 45 65 80 110
mm
m² 0.39 0.39 0.37 0.46 0.462 2 3 3 3
litre 1.36 1.34 1.97 2.35 2.35
pcCOLOUR
COIL
7.00MATERIAL ALUMINIUMFACE AREA
1600
WATER VOLUME
FIN
TUBEMATERIAL COPPERDIAMETER
UNIT DIMENSION - ( ) WITH PANELPACKING DIMENSION - ( ) PANEL
19.05
CASING LIGHT GREY
INDUCTION
ROW
AIR QUALITY
BIP20
RATEDINPUT POWER
RATEDRUNNINGCURRENT
FILTERTYPE WASHABLE SARANET FILTERQUANTITY 1
POLES 8
UNIT WEIGHT (UNIT + PANEL)CONDENSATE DRAIN SIZE
TYPE TURBO FANDRIVE DIRECT
19.05PIPE CONNECTION
FAN SPEEDFAN
FAN MOTOR
MOTOR OUTPUTSTARTING CURRENT
TYPEINDEX OF PROTECTION (IP)INSULATION GRADE
INDO
OR
UNIT
CONTROLAIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN)
HEAD LOSS (COOLING)HEAD LOSS (HEATING) : 50°CMAX. WORKING PRESSURESURFACE AIR VELOCITYSOUND PRESSURE LEVEL (H/M/L/Q)
LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
AIR FLOW
HIGH MEDIUM
QUIET
OPERATION
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENT
265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)
NOMINAL WATER FLOW RATE
POWER SOURCE
LOW
220-240 / 1 / 50
REFRIGERANT TYPE N/A
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
1312
FWKE-E
Wireless Remote ControllerBRC52A
Wired Remote ControllerBRC51A
› Comfortable› Energy Saving› Low Noise› Low Maintenance & No Brush Sparking› 4 Pipe System Available*› Modulating Fan Speed Control› Optimum Air Discharge› Multi Comfort - 3 Air Swing Pattern Control
Ceiling Cassette Type (900x900) With Brushless DC Motor
› Branch Duct Connection› Low Height Design› Built In High Head Drain Pump & Water Flow Switch› Superior Sound Level› Fresh Air Intake› Low Water Pressure Drop› Sleep Function For Cool And Heat Mode› Choices Of Wired Or Withless Remote Controller
Energy SavingCompared to the traditional AC motor, DC motor offers the advantages of lower power input , higher efficiency and hence more energy saving.
• Brushless DC motor has less internal resistance and better heat dissipation in the stator coils. As a result, it has higher operating efficiencies since heat can more efficiently dissipate via the stationary motor housing.
• With the green building and development being so welcomed now, this Ceiling Casstte type with Brushless DC motor gives you another excellent option to consider.
Low NoiseDue to no brushes or a mechnical commutator, it has less shaft friction or inertia and hence less audible noise as low as 16 dBA.
Low Maintenance & No Brush SparkingBrushless DC motor does not use carbon brushes or a mechanical commutator, thus, it is low maintenance and non-sparking.
4 Pipe System Available*4 pipe system allows a distribution system that contains both hot water supply with return lines and a chilled water supply with return lines.* FWKE-EH model
Modulating Fan Speed ControlFan speed modulates steplessly based on room temperature to reduce the difference between room temperature and set temperature and hence provides maximum comfort and reduces energy consumption.* Available in auto fan mode
Recommended ApplicationsCeiling Cassette type fan coil with Brushless DC motor provides a green and pleasant environment.
0
50
100
150
200
600 650 700 750 800 850 900 950 1000 1050 1100
Pow
er In
put (
W)
Air Flow (CFM)
Power Consumption Comparison BetweenAC Motor & DC Motor
AC Motor DC Brushless Motor
Office
Home
Restaurant
67%Energy Saving Maximum
Room
Tem
pera
ture
CFM
Room Temperature v.s. CFM
1514
Specification for Ceiling Cassette Type ~ 50Hz (2 Pipe System)
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
NOTE: A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:FWKE05E MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNITFWKE08/11E MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
NOTE: A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:FWKE05EH MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNITFWKE08/11EH MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGHBtu/h 8200 11900 15900 20100 15200 19800 24700 30000 21000 26800 33100 40100
W 2400 3500 4650 5900 4550 5800 7250 8800 6150 7850 9700 11750Btu/h 5800 8700 11700 15400 11000 14500 18500 21900 14600 18900 23800 28600
W 1710 2540 3440 4510 3220 4260 5410 6430 4270 5540 6970 8370
Btu/h 11300 15200 19800 24200 18400 23900 30400 38200 24100 31600 39100 46700W 3300 4450 5800 7100 5400 7000 8900 11200 7050 9250 11450 13700W 7 12 19 37 17 26 50 90 23 39 83 120
A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
V/Ph/Hz
CFM 220 350 470 620 420 560 720 890 510 680 870 1060
Pa
USGPM 1.84 2.68 3.56 4.52 3.41 4.44 5.55 6.74 4.71 6.01 7.43 9.00
Litres/min 6.96 10.15 13.48 17.10 12.90 16.81 21.02 25.51 17.83 22.76 28.12 34.06
kPa 5 10 15 24 7 9 14 20 15 22 30 41
kPa 4 8 13 21 5 8 12 18 12 20 26 37
kPa
m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83dBA 16 23 31 37 31 37 42 47 34 41 46 51
H X W X D mm
H X W X D mm
kg
mm
mm
RPM 200 280 360 450 350 440 550 660 400 510 630 750
RATED RUNNING CURRENT A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
A
W
mm
m²
Litre
pc
COLOUR
2.35
2 3 3
FWKE05E FWKE08E
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50˚C)
FAN INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE
MODEL
REFRIGERANT TYPE
INDO
OR
UNIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
EXTERNAL STATIC PRESSURE (H/M/L)
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50˚C
MAX. WORKING PRESSURE
SURFACE AIR VELOCITY
FAN
TYPE
DRIVE
SOUND PRESSURE LEVEL
UNIT DIMENSION - ( ) WITH PANEL
PACKING DIMENSION - ( ) PANEL
UNIT WEIGHT
CONDENSATE DRAIN SIZE
PIPE CONNECTION
FAN SPEED
FACE AREA
FANMOTOR
TYPE
INDEX OF PROTECTION (IP)
INSULATION GRADE
STARTING CURRENT
MOTOR OUTPUT
POLES
CASING
FWKE11E
WATER VOLUME
AIRQUALITY FILTER
TYPE
QUANTITY
COIL
TUBEMATERIAL
DIAMETER
FIN
MATERIAL
ROW
ALUMINUM
WASHABLE SARANET FILTER
220-240 / 1 / 50
N/A
4 WAY AUTOMATIC LOUVER (UP & DOWN)LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
1608
IP20
E
1.5
70
IP20
E
2.2
100
BLDC
IP20
E
2.2
70
1
LIGHY GREY
N/A
265 X 820 X 820 (340 X 990 X 990)
341 X 916 X 916 (125 X 1020 X 1020)
300 X 820 X 820 (375 X 990 X 990)
376 X 916 X 916 (125 X 1020 X 1020)
26 + 4 28 + 4 32 + 419.05
19.05
TURBO FAN
7.00
DIRECT
COPPER
8 88
0.39 0.37 0.46
1.36 1.97
Specification for Ceiling Cassette Type ~ 50HZ (4 Pipe System)
QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGHBtu/h 6800 9600 12300 15000 13300 17100 20800 24600 17700 22200 26400 30700
W 2000 2800 3600 4400 3900 5000 6100 7200 5200 6500 7750 9000Btu/h 5300 7600 10200 13100 9900 13000 16600 19600 13300 16700 20700 24500
W 1560 2240 2990 3850 2910 3810 4850 5750 3890 4900 6060 7170
Btu/h 12800 17200 21700 26100 21800 27300 32800 38200 31900 39100 46200 53400W 3750 5050 6350 7650 6400 8000 9600 11200 9350 11450 13550 15650W 7 12 19 37 17 26 50 90 23 39 83 120
A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
V/Ph/Hz
CFM 220 350 470 620 420 560 720 890 510 680 870 1060
Pa
USGPM 1.53 2.14 2.76 3.37 2.99 3.83 4.67 5.51 3.98 4.98 5.93 6.89
Litres/min 5.80 8.12 10.44 12.75 11.31 14.49 17.68 20.87 15.07 18.84 22.47 26.09
USGPM 1.44 1.93 2.43 2.93 2.45 3.06 3.68 4.29 3.58 4.38 5.19 5.99
Litres/min 5.44 9.20 9.20 11.09 9.28 13.91 13.91 16.23 13.55 16.60 19.64 22.68
kPa 5 9 13 18 6 10 15 19 12 19 24 32
kPa 7 10 17 22 13 18 25 32 21 30 39 52
kPa
m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83dBA 16 23 31 37 31 37 42 47 34 41 46 51
H X W X D mm
H X W X D mm
kg
mm
mm
RPM 200 280 360 450 350 440 550 660 400 510 630 750
RATED RUNNING CURRENT A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
A
W
mm
m²
Litre
pc
COLOUR
NOMINAL WATER FLOW RATE (COOLING)
1.36 1.97 2.35
0.39 0.37 0.46
2 3 3
SURFACE AIR VELOCITY
SOUND PRESSURE LEVEL
UNIT DIMENSION - ( ) WITH PANEL
PACKING DIMENSION - ( ) PANEL
CONDENSATE DRAIN SIZE
PIPE CONNECTION
FAN
TYPE
DRIVE
FAN SPEED
FANMOTOR
TYPE
INDEX OF PROTECTION (IP)
INSULATION GRADE
MODELFWKE05EH FWKE08EH
BLDC
POWER SOURCE
REFRIGERANT TYPE
INDO
OR
UNIT
CONTROLAIR DISCHARGE
UNIT WEIGHT
OPERATION
AIR FLOW
EXTERNAL STATIC PRESSURE (H/M/L)
NOMINAL WATER FLOW RATE (HEATING)
FWKE11EH
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50˚C)
FAN INPUT POWER
NOMINAL RUNNING CURRENT
NOMINAL COOLING CAPACITY
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50˚C
MAX. WORKING PRESSURE
STARTING CURRENT
MOTOR OUTPUT
POLES
COIL
TUBEMATERIAL
DIAMETER
FIN
MATERIAL
FACE AREA
ROW
WATER VOLUME
AIRQUALITY FILTER
TYPE
QUANTITY
CASING
220-240 / 1 / 50
N/A
4 WAY AUTOMATIC LOUVER (UP & DOWN)
LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
N/A
1608
265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)
341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)
26 + 4 28 + 4 32 + 419.05
19.05
WASHABLE SARANET FILTER
1
LIGHY GREY
TURBO FAN
DIRECT
COPPER
7.00
ALUMINUM
IP20 IP20 IP20
E E E
70 70 100
8 8 8
1.5 2.2 2.2
1716
FWE-EWireless Remote Controller
BRC52A Wired Remote Controller
BRC51A
› Compact Design› Far Air Throw› Auto Air Swing› Service & Maintenance At Ease› Ceiling & Floor Installing Option› Versatile Installation› Room Temperature Sensing
› Saranet Filter› Sleep Function For Cool And Heat Mode› Auto Restart With Last-State-Memory› Valve Or Valveless Control Options› Self Diagnosis Features› NIM-Able› Choices Of Wired Or Wireless Remote Controller
Ceiling Convertible TypeCompact DesignUnit height as low as 212mm for installation at limited ceiling space.
Auto Air SwingThe motorized louver enables the air flow to be evenly distributed.
Service & Maintenance at EaseThe washable fitler can be easily accessed by just pulling down the intake grill.During servicing or repairing, only the bottom panel needs to be removed in order to access the parts like fan motor, blower, wiring connection, control box, piping connection and so on.
Far Air Throw
Saranet Air FilterThe anti fungus air filter removes air-particles from the air.
Room Temperature SensingAble to sense the room temperature in order to perform more controls for comfort.
Ceiling and Floor Installating OptionThe unit is uniquely designed with possiblity to be installed under or sitting on the floor to suit any interior design requirements.
Versatile InstallationThe unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safery protection.* Drain pump kit supplied as optional item
1090mm
212mm
630mm
Maximum air throw distance up to 16.5m. *Wall bracket is supplied as optional item.
700mm
1918
Choices Of Wired Or Wireless Remote ControllerCompact and user friendly wireless BRC52A and wired BRC51A remote controller offer :• Real Time Clock• "Glow in the dark" ON/OFF Button• Low, Medium, High fan speed options• ON Timer Setting
Sleep Function For Cool And Heat ModeOnce activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment.
Heating mode*
CoolingHo
urs
Tem
pera
ture
Sleep Set On
+0.5˚C
0 1/21
2
+0.5˚C+1˚C
Cooling mode
Heating
Hour
s
Tem
pera
ture
Sleep Set On
-1˚C
-2˚C
-3˚C
0 1/2 12
Wireless Remote Controller BRC52A
Wired Remote ControllerBRC51A62
Power Failure Power Returns
E2 PROME2 PROM
Setting stored before power failure.
RestartStopOperation
Auto Restart with Last-State-MemoryIn case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed.
Valve Or Valveless Control OptionsThe design is flexible enough to allow for either valve or valveless control installation.
Self Diagnosis FeaturesThis feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights.
NIM-AbleAble to communicate with the versatile NIM networking control module and offers the oppurtunity of one centralized control for a system of multiple indoor units in a building.
Specification for Ceiling Convertible Type ~ 50Hz
FWE05E FWE06E FWE07E FWE08E FWE10E FWE12EBtu/h 15500 20300 21000
W 4540 5950 6150248007270
3450010110
4630013570
5160015120
337009880
4000011720
Btu/h 12700 15400 16150W 3720 4510 4730
Btu/h 19500 25000 28000
W 5720 7330 8210W 101 109 113A 0.46 0.49 0.52
V/Ph/Hz
CFM 520 580 620CFM 450 530 570CFM 400 490 520
USGPM 3.43 4.49 4.67Litres/min 13 17 17.68
kPa 27.4 48.1 57.1kPa 24.2 42.1 50.2kPam/s 0.87 1.01 1.08dBA 50 / 43 / 41 53 / 51 / 49 56 / 51 / 44
H X W X D mmH X W X D mm
kgmmmm
HIGH RPM 1192 1346 1380MEDIUM RPM 945 1238 1300LOW RPM 871 1143 1200
HIGH W 101 109 113MEDIUM W 98 108 115LOW W 94 107 113HIGH A 0.46 0.49 0.52
MEDIUM A 0.43 0.47 0.51LOW A 0.41 0.47 0.51
A 5.2 10.3 24W 50 65 70
mm
m²
Litre
pcCOLOUR
NOMINAL TOTAL INPUT POWER
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50 ⁰C)
INDO
OR
UNIT
CONTROLAIR DISCHARGE AUTOMATIC LOUVER (UP & DOWN)
OPERATION LCD WIRELESS MICRO-COMPUTERREMOTE CONTROL
AIR FLOWHIGHMEDIUMLOW
UNIT WEIGHT 27
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)HEAD LOSS (HEATING) : 50 ⁰CMAX. WORKING PRESSURE
NOMINAL RUNNING CURRENTPOWER SOURCE 220-240 / 1 / 50REFRIGERANT TYPE N/A
1608SURFACE AIR VELOCITYSOUND PRESSURE LEVEL (H/M/L)UNIT DIMENSION 212 X 1090 X 630PACKING DIMENSION 297 X 1197 X 740
B
RATED INPUT POWER
RATED RUNNING CURRENT
STARTING CURRENT
CONDENSATE DRAIN SIZE 19.05PIPE CONNECTION 12.7
FAN
TYPE BLOWERDRIVE DIRECT
FAN SPEED
MOTOR OUTPUTPOLES 4
COIL
TUBEMATERIAL COPPERDIAMETER 6.35
FIN
FAN MOTOR
TYPE INDUCTIONINDEX OF PROTECTION (IP) IP 22INSULATION GRADE
MATERIAL ALUMINUMFACE AREA 0.27ROW 3
CASING WHITE
WATER VOLUME 1.11
AIR QUALITY FILTERTYPE WASHABLE SARANET FILTERQUANTITY 2
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
COMING SOON
NOTE: A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMP
COMING SOON
20
FWC-C
Wired Remote ControllerBRC51A
› Excellent Air Distribution› Compact Design› High Capacity Range› High External Static Pressure Range› Double Protection Drainage› East To Service› Left/Right Piping Option
Ceiling Concealed Type
› 4 Useable Fan Speed› Valve Or Valveless Control Options› Self Diagnosis Features› NIM-Able› Auto Restart With Last-State-Memory› Choices Of Wired Or Without Wired Controller
21
Excellent Air DistributionThe air can be distributed evenly to every corner of the room through ducting. This not only presents a confortable environment, it also enables the installation of multiple area by using only one fan coil unit.
Compact DesignUnit height as low as 266mm for installation at limited ceiling space.
High Capacity RangeFrom 3kW to 16kW.
High External Static Pressure RangeAvailable up to 167Pa for high static application like the ducting application.
Double Protection Drainage System There are primary and secondary drain pan from the standard model, which provide extra protection against condensed or water leaking posibilities.
Choices Of With Or Without Wired Remote ControllerCompact and user friendly wired BRC51A remote controller offers:• Real Time Clock• "Glow in the dark" ON/OFF Button• Low, Medium, High fan speed options• ON Timer Setting
Wired Remote ControllerBRC51A
Power Failure Power Returns
E2 PROME2 PROM
Setting stored before power failure.
RestartStopOperation
Auto Restart With Last-State-MemoryIn case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting
Easy To ServiceDirect access to control box at side panel and filter is accessible from side panel too.
Left / Right Piping optionFor flexible installation and application at site
Valve Or Valveless Control OptionsThe design is flexible enough to allow for either valve or valveless control installation
Self Diagnosis FeaturesAbility to detect and diagnose faults and display as error code in the wired controller.
NIM-AbleAble to communicate with the versatile NIM networking control module and offers the oppurtunity of one centralized control for a system of multiple indoor units in a building
702mm
266mm
351mm
Filter Cover
Primary Drain PanPolysterene (PS)With High ImpactPolystyrene (HIPS)Cover
Secondary Drain PanWith Insulation
4 Useable Fan SpeedEach speed offers different external static pressure and air flow which enhances flexibility.
2322
Specification for Ceiling Concealed Type ~ 50Hz
FWC03C FWC04C FWC06C FWC07C
Btu/h 9900 11600 18000 22500W 2900 3400 5280 6590
Btu/h 7000 8120 12600 15750W 2050 2380 3690 4620
Btu/h 11500 15000 23000 29000W 3370 4400 6740 8500W 89 140 168 182A 0.40 0.65 0.77 0.86
V/Ph/Hz
CFM 300 510 700 730CFM 285 490 675 660CFM 260 400 640 580Pa 49 / 44 / 36 49 / 42 / 28 49 / 45 / 41 49 / 43 / 30
USGPM 2.20 2.60 4.05 5.06litres/min 8.33 9.84 15.33 19.15
kPa 10.5 24.0 20.1 32.4kPa 8.8 20.3 17.0 27.6kPam/s 1.29 1.72 1.83 1.72dBA 36 / 35 / 33 40 / 38 / 33 42 / 41 / 40 41 / 40 / 36
H X W X D mm 267 x 702 x 351 267 x 842 x 351 267 x 1002 x 351 267 x 1137 x 351H X W X D mm 376 x 951 x 541 376 x 1091 x 541 376 x 1251 x 541 376 x 1386 x 541
kg 18 22 24 26mmmm
HIGH RPM 128212211117
138512791078
136913311263
134812701072
MEDIUM RPMLOW RPM
HIGH W 89 140 168 182MEDIUM W 86 128 165 175LOW W 78 127 163 163HIGH A 0.40 0.65 0.77 0.86MEDIUM A 0.39 0.59 0.76 0.83LOW A 0.35 0.59 0.75 0.77
A 0.73 1.66 1.22 1.86W 38 72 80 90
mm
m² 0.11 0.14 0.18 0.20
litre 0.94 1.15 1.43 1.63
pcCOLOUR
IP20
PIPE CONNECTION
1608
FAN
19.05TYPE
FAN MOTOR
TYPE INDUCTIONINDEX OF PROTECTION (IP)
N/AQUANTITY
FACE AREAROW
4MOTOR OUTPUT
N/A
WATER VOLUME
AIR QUALITY FILTERTYPE SARANET
CASING
COIL
TUBEMATERIAL COPPERDIAMETER 9.52
FIN MATERIAL ALUMINIUM
3
INSULATION GRADE B
POLES
RATEDINPUT POWER
RATEDRUNNINGCURRENT
STARTING CURRENT
DIRECT
FAN SPEED
PACKING DIMENSIONUNIT WEIGHT CONDENSATE DRAIN SIZE 19.05
BLOWER
HEAD LOSS (HEATING) : 50°CMAX. WORKING PRESSURESURFACE AIR VELOCITYSOUND PRESSURE LEVEL (H/M/L)UNIT DIMENSION
DRIVE
HIGH MEDIUMLOW
NOMINAL WATER FLOW RATE
EXTERNAL STATIC PRESSURE
HEAD LOSS (COOLING)
REFRIGERANT TYPE N/A
INDO
OR
UNIT
CONTROLAIR DISCHARGE DUCTEDOPERATION WIRED MICRO-COMPUTER REMOTE CONTROL
AIR FLOW
POWER SOURCE 220-240 / 1 / 50
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENT
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING AND WIRED/WIRELESS REMOTE CONTROL OPTION
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
Specification for Ceiling Concealed Type ~ 50HZ
FWC09C FWC11C FWC12C FWC14C FWC16C
Btu/h 24800 38000 37000 44700 51800W 7270 11140 10840 13100 15180
Btu/h 19700 29800 29300 35100 40900W 5770 8730 8590 10290 11990
Btu/h 32800 49200 48000 54900 65300W 9610 14420 14070 16090 19140W 345 504 442 427 531A 1.50 2.28 1.93 1.86 2.32
V/Ph/Hz
CFM 830 1250 1240 1340 1550CFM 760 1130 1100 1220 1400CFM 710 1040 1020 1190 1300Pa 167 / 128 / 88 118 / 108 / 88 128 / 88 / 39 157 / 137 / 108 157 / 137 / 98
USGPM 5.55 8.59 8.28 10.04 11.62litres/min 21.01 32.51 31.34 38.00 43.98
kPa 14.0 39.0 23.0 38.0 51.0kPa 11.0 37.0 19.0 33.0 48.0kPam/s 1.40 1.74 1.83 1.54 1.52dBA 46 / 42 / 38 51 / 48 / 45 49 / 45 / 41 52 / 50 / 47 53 / 50 / 47
H X W X D mm 384 x 917 x 462 316 x 1225 x 559 384 x 1003 x 462 384 x 1287 x 462 384 x 1487 x 462H X W X D mm 415 x 1126 x 631 355 x 1461 x 727 415 x 1245 x 631 415 x 1497 x 631 415 x 1701 x 631
kg 42 47 44 50 56mmmm
HIGH RPM 12301093937
138112681169
12601097913
128412031108
130312151067
MEDIUM RPMLOW RPM
IP20 IP21 IP22 IP20 IP20
HIGH W 345 504 442 427 531MEDIUM W 304 380 384 388 466LOW W 270 338 342 373 413HIGH A 1.50 2.28 1.93 1.86 2.32MEDIUM A 1.34 1.72 1.69 1.69 2.02LOW A 1.21 1.53 1.54 1.63 1.81
A 2.43 2.77 3.18 3.50 4.90W 310 470 355 373 500
mm
m² 0.28 0.34 0.32 0.41 0.483 3 3 3 3
litre 2.21 2.66 2.60 3.33 3.80
pcCOLOUR
19.05
1608
FACE AREAROW
WATER VOLUMESARANET
QUANTITY N/ACASING N/A
AIR QUALITY FILTERTYPE
COIL
TUBEMATERIAL COPPERDIAMETER 9.52
FIN MATERIAL ALUMINIUM
FAN MOTOR
TYPE INDUCTIONINDEX OF PROTECTION (IP)INSULATION GRADE B
POLES
RATEDINPUT POWER
RATEDRUNNINGCURRENT
4
19.05TYPE BLOWERDRIVE DIRECT
PIPE CONNECTION
MAX. WORKING PRESSURESURFACE AIR VELOCITYSOUND PRESSURE LEVEL (H/M/L)UNIT DIMENSION
FAN SPEEDFAN
PACKING DIMENSION UNIT WEIGHT CONDENSATE DRAIN SIZE
WIRED MICRO-COMPUTER REMOTE CONTROLHIGH MEDIUMLOW
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
AIR FLOW
220-240 / 1 / 50
REFRIGERANT TYPE N/A
INDO
OR
UNIT
CONTROLAIR DISCHARGE DUCTEDOPERATION
MOTOR OUTPUTSTARTING CURRENT
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY (ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENT
EXTERNAL STATIC PRESSURE
POWER SOURCE
HEAD LOSS (HEATING) : 50°C
NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING AND WIRED/WIRELESS REMOTE CONTROL OPTION
2524
FUD20/25B FUD40/50B
› Excellent Air Distribution› 4 Useable Fan Speed*› Easy To Service› Fire-Resistant Polysthylene Insulation› Left/Right Piping Option
› Cabinet Construction› High External Static Pressure Range› ChangeableDrive Package*› Convertible Air Throw Direction*› High CFM Range
Ducted Blower Type
25
Excellent Air DistributionThe air can be distributed evenly to every corner of the room through ducting. This not only presents a confortable environment, it also enables the installation of multiple area by using only one fan coil unit.
4 Useable Fan Speed*Each speed offers different external static pressure and air flow which enhances flexibility*Only available for FUD20/25B
High CFM RangeFrom 20kW to 40kW and 2500CFM to 4600CFM.
Convertible Air Throw Direction*Convertible discharge air direction (vertical or horizontal air throw) provides flexibility in installation at site*Only available for FUD30/40B
Easy To ServiceThere is a service way allocated at the bottom for servicing available for FUD20/25B
Fire-Resistant Polyrethylene (PE) insulation is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethylene, which is also a type of Closed Cell Foam (CCF) insulation has offered the following advantages:• Durable external surface that resists tough dirt and resilient.• Higher degree of punsture resistance when compared to
fiberglass.• Easily cleaned surface (if necessary) to further resist microbial
growth.
Changable Drive Package*Changeable belt driven package offers flexibility in customizing project based according to application*Only available for FUD30/40B
High External Static Pressure RangeAvailable up to 2256Pa for high static application like the ducting application
Cabinet ConstructionIt is coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for sever external conditions.Service panel is available at the convenience side as well.
Left / Right Piping optionFor flexible installation and application at site.
Ducted Supply Ducted Return
Return Air GrilleAir Discharge Grille
FUD Unit
DuctSystem
FUD UnitConcrete
Plinth
ReturnAir Grille
2726
Specification for Ducted Blower Type ~ 50Hz
FUD20B FUD25B FUD30B FUD40B
Btu/h 75600 95000 125000 150000W 22160 27840 36640 43960
Btu/h 53700 69400 90000 106500W 15740 20340 26380 31210
Btu/h 78000 97500 138000 170000W 22860 28580 40450 49820W 760 1800 1620 1910A 3.49 7.84 3.33 4.03
V/Ph/Hz
CFM 2500 3200 4200 4600CFM 2100 3000 N/A N/ACFM 1750 2800 N/A N/APa 100 / 72 / 50 100 / 80 / 60 230 230
USGPM 16.90 21.10 27.70 33.30litres/min 64.00 80.00 105.00 126.00
kPa 34.5 42.0 48.8 53.3kPa 32.9 27.4 31.5 63.2kPam/s 2.19 2.80 1.96 2.15dBA 50/46/42 54/52/50 58 58
H X W X D mmH X W X D mm
kg 92 102 176 189mmmm
HIGH RPM 835 950 707 707MEDIUM RPM 720 885 N/A N/ALOW RPM 615 805 N/A N/A
HIGH W 760 1800 1620 1910MEDIUM W 611 1620 N/A N/ALOW W 478 1320 N/A N/AHIGH A 3.49 7.84 3.33 4.03MEDIUM A 2.86 7.06 N/A N/ALOW A 2.32 5.82 N/A N/A
A 5.20 10.30 24.00 29.00W 375 500 1500 2200
6 4 4 4
mm
m² 0.54 0.54 1.01 1.013 4 3 4
litre 4.53 6.27 8.14 11.63
pcCOLOUR
MOTOR OUTPUT
380-415 / 3 / 50
IP22
COPPERDIAMETER 9.53
220-240 / 1 / 50
1608
DRIVE
PIPE CONNECTION
IVORY
AIR QUALITY FILTER
POLES
N/AQUANTITY
ALUMINIUMCOIL
TUBEMATERIAL
DIRECT BELT
N/ACASING
FAN MOTOR
FACE AREAROW
WATER VOLUME
INDUCTION
INDEX OF PROTECTION (IP)
TYPE
FIN MATERIAL
B
RATEDINPUT POWER
RATEDRUNNINGCURRENT
STARTING CURRENT
UNIT WEIGHT CONDENSATE DRAIN SIZE 19.05
FAN SPEED
28.58TYPE BLOWER
INSULATION GRADE
TYPE
762 x 1605 x 880885 x 1540 x 850
1154 x 1787 x 1188
HEAD LOSS (COOLING)HEAD LOSS (HEATING) : 50°CMAX. WORKING PRESSURESURFACE AIR VELOCITYSOUND PRESSURE LEVEL UNIT DIMENSION PACKING DIMENSION
HIGH MEDIUMLOW
NOMINAL WATER FLOW RATE
EXTERNAL STATIC PRESSURE
572 x 1402 x 605
N/A
INDO
OR
UNIT
CONTROLAIR DISCHARGE DUCTEDOPERATION
FAN
WITHOUT CONTROLLER
AIR FLOW
POWER SOURCE
REFRIGERANT TYPE
MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)
NOMINAL TOTAL INPUT POWERNOMINAL RUNNING CURRENT
COOLING27˚C DB / 19˚C WB
7˚C
12˚C
HEATING20˚C DB
50°C (2 Pipes System)70°C (4 Pipes System)45°C (2 Pipes System)60°C (4 Pipes System)
MODEENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
LEAVING WATER TEMPERATURE
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING.
Features:• Cool/Heat/Fan/Dry/Auto mode• Auto/High/Med/Low fan speed• Temperature operate in ºC and ºF• Turbo and Quiet Function• Sleep function• Swing function• Real time clock and day display• 7-days programmable timer• Error indicator• Key lock and fan lock features• Batteries backup and retain setting during power failure• Last state memory (Memory backup setting from main board)• Delay Timer (1 or 2 hours)• Interaction with Wireless Handset (BRC52A61/BRC52A62)
1. Vertical Automatic Air Swing2. Selectable Mode: Auto Mode, Cooling , Heating, Dry, Fan3. Turbo Function4. Quiet Function5. ON Timer Setting6. Real Time Clock7. Transmission Source8. “Glow in the dark” ON/OFF Button9. Fan Speed Selection: Low, Med, High, Auto10. Temperature Setting: Up & Down11. Sleep Mode Function12. OFF Timer Setting
1
7
8
9
101112
234
5
6
BRC52A61 – Heatpump with auto modeBRC52A62 – Cooling onlyBRC52A63 - Heatpump
BRC51A61 – Heatpump with auto modeBRC51A62 – Cooling only
ControllerBRC52A
BRC51A
2928
NIM
Main Board Controllers And Display Control PanelNIM must be used in conjunction with:
• DX fan coil units (except FT(Y)N model. The development is in progress and kindly contact with local distributor for status update.)• BRC51A or BRC52A
Network Interface Module (NIM) is a networking system which enables communication among Daikin air conditioners.With the Network Interface Module (NIM), all your air conditioning systems can be controlled with just a single controller giving you benefits:
Benefits• More convenience. No more individually controlling air conditioning units• Quicker and easier zone control from the master control unit• Better control of air conditioning systems operating conditions
NIM utilizes master-slave type system whereby the master node will issue commands to each of the slave nodes.
Every master unit will have a group address so that every slave can only response to their respective master. Each slave unit must have a unique address so that it can be addressed independently of other nodes.
The master unit will be operating in conjunction with a control panel. Any settings done via the control panel connected to the master will overwrite the settings of its slave units.
Slave unit can be operated with or without control panel. If a slave unit is operating with a control panel, its settings can be changed without following its master.
Basic Features• DIP switch setting for Group & Unit address.• Master or slave system configuration.• Automatic detection of control panel existence.• Error type and unit ID indication through display control panel.
• Maximum point to point communication bus up to 1000m.• A single master unit can control up to 15 slave units in each group.• Each slave unit will sense their individual local temperature.• Unit address range from 0 to 15 (0000-1111).
The NIM System Consists Of• Main Board controller • Display control panel • NIM controller • Communications bus
Intelligent Control Series
Network Control NIM
(up to total of16 FCUs)
Slave(s)Slave(s)SlaveMaster
Connection
ConnectionThe communication bus must be connected serially to the adjacent NIM. (Daisy chain connection). The same polarity has to be connected between the NIMs (A to A, B to B).
Communication BusA 2-way twisted pair cable is used as the communication bus. Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5mm to 1.0mm.
Supported Configuration
BRC51A
BRC52A
Master Slave
G-Way
First NIM to the furthestconnected NIM 1000
10
10
Connection
NIM to Main Board
NIM to Wired Controller
Recommended Maximum Cable Length (m)
G-Way
To MainBoard
To Wired Control Panel
CN2
CN1 RELAY 1
RELAY 2
DIP SwitchTerminalBlocks
NO
NO
COM
COM
Dry ContactOutput 1
Dry ContactInput
Dry ContactSwitch
Unit On/OffIndicator
Unit ErrorIndicator
BMSG-Way Controller
Dry ContactOutput 2
1000 m
Types of Operation DSW2 Setting
Control & Monitor (Ext. Switch Closed = ON A/C) 0000
0010
0001
Control & Monitor (Ext. Switch Open = ON A/C)
Monitoring only
Function• Gateway between DX fan coil unit and basic Building Management System (BMS).
Note: • Remote (On/Off) control of air conditioner via BMS.• Unit error indication via BMS and BRC51A controller.• Unit operation status monitoring via BMS.• Maximum point to point communication bus between air conditioner and BMS of up to 1000m.• DIP switch setting for control or monitoring function.
DSW2 Setting
30
• Laboratory• Railway Switching Center• Room with Critical Electronics Equipments
• S-NIM controller• Communication Bus
S-NIM
Master Unit
Slave Unit
Typical connection structure for S-NIM
Main Board Main Board
Control Panel
The S-NIM System Consists Of• Main Board controller• BRC51A
Communication BusA 2-way twisted pair cable is used as the communication bus.Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5mm to 1.0mm.
S-NIM Controller Application• Server Room• Telecommunication Tower• Livestock Breeding Farm• Warehouse
S-NIM For Timer Switchover Control
Built on the NIM configuration, S-NIM serves to enhance the abilities and extend the operating lifetime of existing air conditioning units in harsh and demanding environment.
S-NIM works in a master & slave system, operating at alternate sequence of preset hours. Whenever the operating unit is at fault, the standby unit will automatically takes over.
Features• Auto restart feature with last state settings.• 2 air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/4/5/7/9/11/12 hours).• System controlled by a single BRC51A controller.• When the operating unit is at fault, the standby unit automatically takes over.• Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)• During system OFF mode, running timer will stop. It resumes when changing to ON mode.• Preset operation hours can be set via DIP Switch.* The air conditioning unit connected to the wired controller is always the master unit.
S-NIMS-NIM