Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide April 29, 2011

Transcript of VXI Config Guide

Page 1: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide April 29, 2011

Page 2: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 2

Contents Goal .............................................................................................................................................................. 5

Audience ...................................................................................................................................................... 5

Objectives .................................................................................................................................................... 5

Design Overview ......................................................................................................................................... 2

Data Center Compute and Storage Components .................................................................................. 10 Cisco Unified Computing System ........................................................................................................... 10

Cisco UCS 2100 Series Fabric Extender ........................................................................................... 12 Cisco UCS 6100 Fabric Interconnect ................................................................................................. 12 Cisco UCSM Configuration ................................................................................................................ 14 UCS 6100 Uplink Storage Configurations .......................................................................................... 17

Fibre Channel Storage Components ...................................................................................................... 18 NFS Storage Components ...................................................................................................................... 22 Cisco Unified Computing System C-Series and DAS Storage ............................................................... 22 Cisco Nexus 1000v ................................................................................................................................. 23 Atlantis ILIO ............................................................................................................................................ 27 Cisco VSG .............................................................................................................................................. 27 Cisco vWAAS .......................................................................................................................................... 27 McAfee MOVE-AV .................................................................................................................................. 28 Hypervisor Installation and Configuration ............................................................................................... 28

VMware ESX/ESXi ............................................................................................................................. 28 Microsoft Hyper-V ............................................................................................................................... 28

Desktop Virtualization Software Installation and Configuration .............................................................. 29 VMware View Configuration ............................................................................................................... 29 Citrix XenDesktop Configuration ........................................................................................................ 29

Data Center Networking Infrastructure ................................................................................................... 31 Cisco Nexus 5010 Access Layer Switch ................................................................................................ 31 Cisco Nexus 7010 ................................................................................................................................... 33 Cisco Application Control Engine (ACE4710) ........................................................................................ 33 Cisco Adaptive Security Appliance (ASA5580) ...................................................................................... 35 Cisco WAN Acceleration Engine (WAE-512) ......................................................................................... 36 Cisco Network Analysis Module (NAM2220) .......................................................................................... 36

Campus Network ....................................................................................................................................... 37 Cisco Catalyst 6504E (CAT6504E) ........................................................................................................ 38 Cisco 7206VXR Router ........................................................................................................................... 38 Cisco WAN Acceleration (WAE-674) ...................................................................................................... 38 Cisco Adaptive Security Appliance (ASA5540) ...................................................................................... 39 Cisco Integrated Service Router (ISR3945) ........................................................................................... 39 Cisco Catalyst 4500E (Campus Access CAT4500E) ............................................................................. 39 Cisco Catalyst 4507E (Campus Access CAT4507E) ............................................................................. 39 Cisco Aironet Access Points ................................................................................................................... 40 Cisco 5508 Wireless Controller .............................................................................................................. 40 Cisco 3310 Mobility Services Engine ..................................................................................................... 40

Branch Configurations ............................................................................................................................. 40 Branch 1 – Branch connection with PfR ................................................................................................. 40 Branch 2 – Branch connection with external WAVE-674 ....................................................................... 43 Branch 3 – Branch connection with no WAAS ....................................................................................... 44 Branch 4 – Branch connection with WAAS SRE Module ....................................................................... 44 Branch 5 – Identical to Branch 3 except uses 3945 ............................................................................... 45 Branch 6 – Branch connection with WAAS Express .............................................................................. 45 Branch 7 – Identical to Branch 3 except uses 3945 ............................................................................... 46 Branch 8 – Identical to Branch 3 except uses 2951 ............................................................................... 46

Page 3: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 3

Branch 9 – Direct Connection using Site-to-Site VPN ............................................................................ 46 Branch 10 – Direct Connection using AnyConnect VPN ........................................................................ 47

Appendix 1 – Location Tracking .............................................................................................................. 47

Appendix 2 - Endpoint security 802.1x, MacSec, MAB, ACS ............................................................... 49

Appendix 3 – QOS settings in VXI ........................................................................................................... 52

Appendix 4 – CUPC and Deskphone control ......................................................................................... 57

Appendix 5 – Netflow and Energywise ................................................................................................... 63

Page 4: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 4

Figures Figure 1: CVD Test Configuration .............................................................................................................................. 2 Figure 2: Network Map showing IP addresses .......................................................................................................... 3 Figure 3: Virtual Infrastructure ................................................................................................................................... 4 Figure 4: Server Configuration ................................................................................................................................. 10 Figure 5: Logical Diagram of the Cisco UCS Compute Components ...................................................................... 12 Figure 6: Complete UCS System Block ................................................................................................................... 13 Figure 7: UCS 6120 Uplink Storage Connectivity .................................................................................................... 18 Figure 8: Data Center Network Components ........................................................................................................... 31 Figure 9: Campus Network Components ................................................................................................................. 37 Figure 10: Branch 1 Design ..................................................................................................................................... 41 Figure 11: Branch 2 Network Design ....................................................................................................................... 43 Figure 12: Branch 3 Network Design ....................................................................................................................... 44 Figure 13: Branch 4 Network Design ....................................................................................................................... 45 Figure 14: Branch 6 Network Design ....................................................................................................................... 45 Figure 15: Branch 9 Network Design ....................................................................................................................... 46 Figure 16: Branch 10 Network Design ..................................................................................................................... 47

Tables Table 1: Data Center Compute Components............................................................................................................. 5 Table 2: Data Center Storage Components ............................................................................................................... 6 Table 3: Data Center Network Components .............................................................................................................. 7 Table 4: Campus Network Components .................................................................................................................... 7 Table 5: Branch Components .................................................................................................................................... 9 Table 6: Supporting Application Services .................................................................................................................. 9

Page 5: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 5

Goal This document reports the tested configuration for the VXI Release 2.0 architecture. It includes specific device configurations and diagrams showing interconnections.

Audience This document is intended to assist solution architects, sales engineers, field engineers and consultants in planning, design and deployment of the Cisco VXI System. This document assumes the reader has an architectural understanding of the Cisco VXI system and has reviewed the Cisco VXI Release 2.0 CVDs for Citrix XenDesktop and VMware View.

Objectives This document is intended to articulate the overall design and VXI specific configurations of the tested architecture called out in the VXI Release 2.0 CVDs for Citrix XenDesktop and VMWare View.

Page 6: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 2

Design Overview The design implemented in the Cisco VXI CVD replicates a customer’s network, end-to-end, from the datacenter to the endpoints installed either in the campus or branch environment. Figure 1 shows the complete system test setup. Discussion for each of the sections are show following. Figure 1: CVD Test Configuration

Release 2.0 of the VXI CVD is based on existing selling equipment from both Cisco and its Technology Partners. Where possible the preferred operating mode and configuration was used, unless specific commands or configurations yielded improvements or enhancements to the Desktop Virtualization (DV) experience. Due to the number of devices in the VXI CVD test setup, the configuration files for each device are included as hyperlink references throughout the document. Refer to the Appendix section of this document for guidance on completing VXI specific use cases.

Page 7: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 3

Figure 2: Network Map showing IP addresses

Page 8: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 4

Figure 3: Virtual Infrastructure

Page 9: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 5

Table 1: Data Center Compute Components

Component Software Release

Cisco Unified Computing System: • UCS 5108 • B200 M1 & M2 • B250M2 • B230 M1 • UCS 6120 Fabric Interconnect • UCS Manager

1.4.1j

Cisco Unified Computing System: • C250 M2

1.4.1j

VMware ESXi /ESX 4.1

VMware vSphere/vCenter 4.1

Microsoft Hyper-V

Windows 2008 R2 64-bit

Microsoft SCVMM

Windows 2008 R2 64-bit

Citrix XenServer 5.6 FP1

Cisco Nexus 1000v 4.2.1 SV1(4)

Cisco Virtual Security Gateway

4.2.1 VSG1(1)

Cisco vWAAS

4.3.1

VMware View Connection Server 4.5 / 4.6

VMware View Composer 2.5.0.291081

VMware View Agent 4.5 / 4.6

Citrix XenDesktop 5.0

Citrix PVS 5.6.0 SP1

Citrix XenApp

6.0

Page 10: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 6

Microsoft Windows 7 & XP SP3

McAfee MoveAV

1.5

McAfee VSE

7.3

Cisco Unified Presence Client (CUPC) 8.5

WebEx/WebEx Connect 7

Microsoft Lync

2010

Table 2: Data Center Storage Components

Component Software Release

Cisco MDS 9222i 5.0(1a)

EMC Celerra NS-480 FLARE 4.30

EMC Unisphere 6.0.36-4

NetApp FAS 3170 8.0.1

NetApp Mgmt. Software 1.1 R2

Atlantis ILIO 2.0.2

Page 11: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 7

Table 3: Data Center Network Components

Component Software Release

Cisco Nexus 5000 5.0(2)N1(1)

Cisco Nexus 7010 NxOS 5.1(2)

Cisco - Data Center Network Manager (DCNM) 5.1(2)

Cisco Application Control Engine (ACE) 4710 A3 (2.5)

Cisco ACE Device Manager A3 (2.5)

Cisco Adaptive Security Appliance (ASA) 5580 8.3.1

Cisco NAM Appliance 2220 5.0(1)

Cisco Adaptive Security Device Manager (ASDM) 6.2.5

Cisco WAAS central manager 4.3.1

Table 4: Campus Network Components

Component Software Release

Catalyst 6504-Sup720 12.2(33)SXI5

Cisco 7206VXR NPE-G1 15.0(1)M4

Cat 4507R-E 122-54.SG

Cisco WAE 674 4.3.1

Cisco Adaptive Security Appliance (ASA) 5540 8.3.1

Cisco ISR 3945 G2 15.1(T3)

CiscoWorks LAN Management Solutions (LMS) 4.0

Cisco Aironet Access Point 7.0.98.0

Page 12: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 8

Cisco 5508 Wireless Controller

7.0.98.0

Cisco Wireless Control System

7.0.164

Cisco Mobility Services Engine

7.0.105.0

Page 13: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 9

Table 5: Branch Components

Component Software Release

Cisco ISR 3945 G2 15.1(T3)

Cisco ISR 3845 15.1(T3)

Cisco WAE 674 4.3.1

NM-WAE module for ISR 4.3.1

WAAS Express

4.3.1

Catalyst 3560 / Catalyst 3750 12.2(35)SE1

Networked Printers Win 2008

Cisco 99xx, 79xx IP Phones 99xx.9-0-2, 79xx.9-0-2SR1

Cisco VXC2111 / VXC2211 (PCoIP)

3.3.1

Cisco VXC2112 / VXC2112 (ICA) 7.0.0.30

Apple iPad 4.2.1

Wyse Xenith, Wyse P20 Embedded OS

Wyse R90LEW, X90LW Embedded WinXP/Win7

Wyse V10L

Wyse Thin OS

Wyse R50

Linux

DevonIT TC5DW DeTOS

DevonIT TC5XW Embedded WinXP

IGEL UD7 Embedded WinXP

Table 6: Supporting Application Services

Component Software Release

Cisco Unified Communication Manager 8.5

Page 14: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 10

Cisco Unity Connection 8.5

Cisco Unified Presence Server (CUP) 8.5

WebEx/WebEx Connect 7

Microsoft Active Directory Domain Controllers Win 2008

Cisco Secure Access Control System 5.1.0.44

DNS Win 2008

DHCP Win 2008

SSC 5.1

AnyConnect 3.0

Data Center Compute and Storage Components This section describes the Data Center infrastructure components used in the CVD configuration. The design for the data center uses guide lines from the Data Center 3.0 CVD available on the Cisco Design Zone. It deploys the standard three tier model: Access, Aggregation, and Core. Service Appliances are connected to the Aggregation Layer and are covered in this section.

Cisco Unified Computing System The Cisco Unified Computing System is used to host the virtual desktops and desktop virtualization servers. For the Cisco UCS B Series, three Cisco UCS 5108 Blade enclosures were used for the test. Two enclosures contain eight half width Cisco UCS B200 blade servers each and one enclosure contains four full width UCS B250 blade servers. The Desktop Virtualization (DV) machines are distributed across all three enclosures. Cisco VXI also has validated two configurations of the Cisco UCS C Series Rack Mount server. The Cisco UCS M71KR-Q Converged Network Adapter (CNA) mezzanine card was used for this test. It provides two 10 Gigabit Ethernet NICs and two Fibre Channel HBAs combining them into two Fibre Channel over Ethernet (FCoE) interfaces. The hypervisor will map these interfaces to the various VLANs needed to support the DV environment. Figure 4: Example Server Configuration (Cisco UCS B Series shown)

Page 15: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 11

Page 16: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 12

Cisco UCS 2100 Series Fabric Extender The Cisco UCS 2104XP Fabric Extender (FEX) has four 10 Gigabit Ethernet, FCoE-capable, Small Form-Factor Pluggable Plus (SFP+) ports that connect the Cisco B5108 blade chassis to the Cisco UCS 6100 fabric interconnect and eight 10 Gigabit Ethernet server ports connected through the mid-plane, one to each half-width slot in the chassis. Figure 5: Logical Diagram of the Cisco UCS Compute Components

Cisco UCS 6100 Fabric Interconnect The Cisco® UCS 6100 Series Fabric Interconnects are a core part of the Cisco Unified Computing System, providing both network connectivity and management capabilities for the system (Figure 4). Each uplink from the UCS 2104XP FEX is connected to a 10G FCoE Port on the UCS 6100.

Page 17: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 13

Figure 6: Complete UCS System Block

Page 18: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 14

Cisco UCSM Configuration

The Cisco UCS Manager (UCSM) is used to configure the various elements of the Cisco Unified Computing System. Cisco UCSM runs in the Cisco UCS 6100 Series Fabric Interconnects, and provides multiple interfaces (including GUI and CLI) for managing a UCS instance. Each Fabric Interconnect has a unique IP address. A Virtual IP address is created to link the two switches and provide a single point of management. Cisco UCSM is accessed via a browser.

Cisco UCSM can be used to manage all hardware in a UCS instance (chassis, servers, fabric interconnects, etc) and all resources (servers, worldwide name addresses, MAC addresses, UUIDs, bandwidth). It also provides tools for server, network, and storage administration. Because of the breadth and depth of its capabilities, a detailed explanation of the Cisco UCSM configuration is far beyond the scope of this document. The fundamental elements of a Cisco UCS configuration include:

• System: configuring the Fabric Interconnects, ports, communication servers, role-based access controls, DNS servers, authentication, firmware management, and more

• Network: configuring VLANs, LAN pin groups, MAC pools, QoS, and other network-related policies

• Storage: configuring Named VSANs, SAN pin groups, WWN pools, and other storage related policies

• Server: configuring server-related pools, management IP addresses, server-related policies, service profiles, and power management

• VN-Link: configuring VN-Link components, distributed virtual switches, port profiles, VN-Link related policies, and pending deletions

Page 19: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 15

• System Management: managing time zones, chassis, servers, I/O modules, configurations, and passwords

• System Monitoring: monitoring traffic and hardware, configuring statistics-related policies, managing the event log, configuring settings for faults, events, and logs, configuring call home

Cisco UCS Service Profiles Service Profiles are the central concept of Cisco UCS. A service profile ensures that associated server hardware is properly configured to support the application it will host. The service profile defines server hardware, interfaces, fabric connectivity, server identify, and network identity. Service profiles are centrally managed and stored in a database on the Cisco UCS 6100 Series Fabric Interconnect. Every Cisco UCS server must be associated with a service profile. Service profile templates facilitiate the rapid creation and deployment of service profiles. The following example shows a truncated version of a single Cisco VXI service profile.

enter service-profile S3B4 instance associate server 3/4 enter vcon 2 enter vhba HBA-A fabric a set adapter-policy VMWare set fabric a set fc-if name SONS-VSAN-Fabric-A set max-field-size 2048 set order 1 set pers-bind disabled set pin-group "" set qos-policy "" set stats-policy default set template-name vHBA_FI-A set vcon any exit enter vhba HBA-B fabric b . . . exit enter vnic NIC-A fabric a-b enter eth-if EMC-NFS set default-net no exit enter eth-if NetApp-NFS set default-net no exit enter eth-if NetApp-iSCSI set default-net no exit enter eth-if PXE-Boot-999 set default-net yes exit . . .

Page 20: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 16

set adapter-policy VMWare set fabric a-b set mtu 9000 set nw-control-policy CDP-On set order 3 set pin-group "" set qos-policy "" set stats-policy default set template-name vNIC_SON_FI-A set vcon any exit enter vnic NIC-B fabric b-a . . . exit power up set bios-policy SONS-BIOS set boot-policy SONS-boot set descr "" set dynamic-vnic-conn-policy "" set ext-mgmt-ip-state none set host-fw-policy 1.4.1j set ipmi-access-profile "" set local-disk-policy SONS-mirror set maint-policy "" set mgmt-fw-policy "" set power-control-policy default set scrub-policy "" set sol-policy default set src-templ-name SONS set stats-policy default set user-label "" set vcon 2 selection all set vcon-policy "" exit

The UCSM configuration screenshots can be found here : UCS Manager Configuration. The configuration file for the UCS6120 was captured by using SSH to get access to the CLI and issuing the command: show config >> sftp://<host>/<path>/<dest_filename>" The complete configuration for the UCS6120 can be found here : UCS 6120 Configuration. NOTE To enable Jumbo Frames for both NFS and FC storage, use the QOS configuration on the Cisco Unified Computing System Manager. Configure platinum policy by checking the Platinum policy box and if you want jumbo frames enabled change MTU from normal to 9000. Use the option to set no packet drop policy during this configuration.

Page 21: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 17

UCS 6100 Uplink Storage Configurations Two sets of uplinks are provided on the UCS 6100. One set is used for Fibre Channel (FC) connectivity to FC based storage. These uplinks are located on the module slot. The second set is used for Ethernet connectivity including access to NFS storage. Ethernet ports on the module slot or from the built-in ones can be used for this purpose. Figure 7shows this portion of the system configuration.

Page 22: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 18

Figure 7: UCS 6120 Uplink Storage Connectivity

Fibre Channel Storage Components A pair of MDS Series switches was used in the configuration to connect the Cisco UCS 6120 Fabric Interconnect Fibre Channel ports to the storage array (see Figure 7). The MDS switches provide an optimized platform for deploying Storage Area Networks (SANs), intelligent fabric services, and multiprotocol connectivity. These switches support high density Fibre Channel switching, hardware-based virtual fabric isolation with VSANs, Fibre Channel-based Inter-VSAN routing, iSCSI connectivity for Ethernet-attached servers, and a wide range of additional advanced services. In the Cisco VXI validated design testing, the MDS Series SAN switches enabled e Boot from SAN support for the Cisco UCS Series servers. The MDS series switches can be configured by means of a command line interface (CLI), or using the Cisco Fabric Manager. Detailed information on configuring MDS Series basic and advanced services can be found at Cisco MDS Series configuration guide. The complete MDS 9222i configuration can be found: MDS9222i Configuration. The key elements of the Cisco VXI test configuration include definitions for the following:

• VSANs • Interfaces • Zones and Zone Sets • N-Port ID Virtualization

VSANs A VSAN is a virtual storage area network. VSANs provide isolation among devices that are physically connected to the same fabric. VSANs enable the creation of multiple logical SANs over a common physical infrastructure. Each VSAN contain up to 239 switches, and has an independent address space so that identical Fibre Channel IDs can be used simultaneously in different VSANs. The VSANs must be consistent on the VMware vSphere hosts, the Cisco UCS Series servers, the Cisco MDS Series switches, and the Fibre Channel storage array. VSAN configuration can be done either in the MDS

Page 23: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 19

Series switch CLI or the Cisco MDS Device manager. Cisco Fabric Manager can also be used for managing the SAN configuration and zoning information. Configuring VSANs requires the following: Creating the VSANs in the database:

vsan database vsan 100 name "vxi_triage_auto_a" vsan 200 name "vxi_soncs_ls_a" vsan 300 name "vxi_infra_a"

Configuring persistent Fibre Channel IDs in each VSAN:

vsan 1 wwn 20:41:00:0d:ec:f9:b3:c0 fcid 0x6d0000 dynamic vsan 1 wwn 20:43:00:0d:ec:f9:b3:c0 fcid 0x6d0001 dynamic vsan 1 wwn 20:45:00:0d:ec:f9:b3:c0 fcid 0x6d0002 dynamic vsan 1 wwn 50:06:01:60:3c:e0:60:04 fcid 0x6d00ef dynamic

.

.

. vsan 200 wwn 20:00:00:25:b5:22:01:7f fcid 0xbc0027 dynamic

Assigning interface membership to the appropriate VSAN:

vsan database vsan 100 interface fc1/1 vsan 200 interface fc1/2 vsan 100 interface fc1/3 vsan 100 interface fc1/4 vsan 200 interface fc1/5

.

.

. vsan 300 interface fc2/24

Interfaces The interface is the mechanism through which frames are transferred. Each interface must be defined and its operating characteristics specified. Configured interfaces can be Fibre Channel, Gigabit Ethernet, management, or VSAN interfaces. Interfaces can be associated with a particular owner, and traffic flow can be enabled or disabled. The example shows a Fibre Channel interface associated with owner Triage-a1, and with traffic flow enabled.

interface fc1/3 switchport owner Triage-a1 no shutdown

Zones and Zone Sets Zoning enable administrators to control access between storage devices and/or user groups. Zones can be used to provide an added measure of security, and to prevent data loss or corruption. Zoning is enforced based on source-destination ID fields. A zone consists of multiple members, and is usually based on member worldwide names (WWNs) or Fibre Channel IDs (FC IDs). A zone member can access other zone members; non-zone members cannot access zone members. The example shows creation of a zone named emc1-a2_s4b7-a for VSAN 200. Two members (one target and one initiator) are assigned to this zone, based on Port WWNs.

Page 24: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 20

zone name emc1-a2_s4b7-a vsan 200 member pwwn 50:06:01:64:3c:e0:60:04 ! [emc1-a2] member pwwn 20:00:00:25:b5:22:02:7e ! [s4b7-a]

A Zone Set is a collection of zones. A zone set can be activated or deactivates as a single entity across all switches in the fabric. A zone can be a member of multiple zone sets. Only one zone set can be activated at a given time. The example shows the creation of a zone set named vxi_soncs_ls_a in VSAN 200, and the assignment of the member zones in this set. The example also shows the zone set being activated.

zoneset name vxi_soncs_ls_a vsan 200 member emc1-a2_s1b1-a member emc1-b2_s1b1-a member emc2-a2_s1b1-a member emc2-b2_s1b1-a member emc1-a2_s1b3-a member emc1-b2_s1b3-a member emc2-a2_s1b3-a

.

.

. member emc2-b2_s1b7-a2 zoneset activate name vxi_soncs_ls_a vsan 200

N-Port ID Virtualization The uplink FC ports on the UCS 6120 operate in N-Port Virtualization (NPV) mode. The uplink ports operate in a similar mode to host ports (referred to as N-Ports in the FC world). To support NPV on the UCS 6120, the N-Port ID Virtualization (NPIV) feature must be enabled on the MDS 9222i Switch. # show feature | grep npiv npiv 1 enabled # show interface br ------------------------------------------------------------------------------- Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps) ------------------------------------------------------------------------------- fc1/1 1 auto on up swl F 4 -- fc1/2 1 auto on up swl F 4 -- fc1/3 1 auto on up swl F 4 -- fc1/4 1 auto on up swl F 4 --

EMC Unified Storage Cisco VXI validation testing employed a EMC Unified Storage system and high bandwidth fibre channel connectivity to provide a Boot from SAN capability. In addition to fibre channel, the EMC system also supports iSCSI and NAS storage. The system is composed of two to four autonomous servers and a Storage Processor Enclosure (SPE). The servers (also called X-Blades) run the operating system and provide block (and file) access. The SPE manages the disk arrays. The system provides up to 192 TB of storage capacity.

Page 25: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 21

Detailed configuration of the EMC Unified Storage system is beyond the scope of this document. The basic approach is to begin by connecting the EMC FC ports to the Cisco MDS Series SAN switches. Adminstrators also should ensure that the FC zoning process has been completed. The next step is to create a Raid Group (Raid 1/0), and then to create LUNs from that group. Then a storage group is created, and VMware vSphere hosts (which will access the LUNs) are added to the group. Finally, the newly created LUNs are added to the storage group. When these steps are completed, vCenter Server is used to rescan the FC adapter for new storage devices. After the rescan, the FC LUN will be added to storage. Refer to EMC documentation for specific configuration guidance on provisioning EMC Unified Storage in virtual desktop environments : http://www.emc.com/collateral/solutions/reference-architecture/h8020-virtual-desktops-celerra-vmware-citrix-ra.pdf http://www.emc.com/collateral/software/technical-documentation/h6082-deploying-vmware-view-manager-celerra-unified-storage-plaform-solution-guide.pdf

Page 26: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 22

NFS Storage Components As shown in Figure 7 above, the NFS based storage array is connected to the Cisco Nexus 5000. In the Cisco VXI validated design, this array was deployed to store user data. The Cisco VXI system tested a NetApp FAS series storage system for NFS storage. The NetApp FAS series is a unified storage platform that provides primary and secondary storage with simultaneous file and block services. This system supports up to 840 drives with a total capacity of over 16 TB. The NFS array needs to have L2 adjacency to the hypervisors. If the array is on another L2 segment then special routes will need to be manually added to both the array and the hypervisor connections. The NFS array can be connected to another Cisco Nexus 5000 or the Cisco Nexus 7000 as long as the L2 adjacency is maintained. Jumbo Frames need to be configured on all the Ethernet switches that make up the pathway between the hypervisors and the NFS storage array. Detailed configuration of the NetApp FAS system is beyond the scope of this document. Please refer to the NetApp documentation for specific details on configuration. To provision NFS storage on the NetApp system, the first step is to create an aggregate, which is a collection of disks. The general recommendation is to configure an aggregate of maximum possible size. The next step is to configure a default flexible volume for NFS exports, which can grow to the size of the aggregate. Once the aggregate is created, additional Flexible Volumes can be defined if needed. Disk space can be reserved for the volume, or it can configured to grow only as data is written. The configuration process also involves defining interface characteristics and NAS volumes. For VMware environments using NFS storage, NetApp recommends increasing the number of VMware vSphere data stores from the default value of 8 to 64, so that additional data stores can be dynamically added as needed. NetApp also suggests changing NFS.HeartbeatFrequency to 12, and NFS.HeartbeatMaxFailures to 10 for each ESX host. Refer to NetApp documentation for specifc configuration guidance on provisioning NetApp Storage in virtual desktop environment : NetApp Windows Host Utilities 5.3: http://now.netapp.com/knowledge/docs/hba/win/relwinhu53/pdfs/setup.pdf NetApp DSM 3.4 for Windows Multi-Path I/O: http://now.netapp.com/knowledge/docs/mpio/win/reldsm34/pdfs/install.pdf NetApp SnapDrive 6.3 for Windows http://now.netapp.com/knowledge/docs/snapdrive/relsnap63/pdfs/admin.pdf NetApp SnapManager for Hyper-V 1.0 http://now.netapp.com/knowledge/docs/smhv/relsmhv10/pdfs/install.pdf

Direct Attached Storage

Page 27: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 23

The Cisco UCS C-Series (C250 M2) was tested with DAS storage in two configurations : 2x100GB SSD with 6x300GB SAS and 8x300GB SAS. In the Cisco VXI validated design deployment, the UCS C Series local storage was used to store both boot images and user data. VMware vSphere was installed on the UCS Server, which was configured to boot from the local hard disk. Local disk policy was configured on the server to create a RAID LUN (raid-1-mirrored) as shown in the following example:

enter local-disk-config-policy SONS-mirror set descr "SONS Local Disk Cfg Policy" set mode raid-1-mirrored set protect yes exit There are several caveats involving the interaction of UCS C Series servers, UCS Manager, and RAID storage controllers when configuring local storage. For best results, consult the UCS Manager Configuration Guide to understand the conditions that may apply in a given situation.

Atlan tis ILIO Atlantis ILIO, a storage optimization software solution, was tested with the UCS C-Series. Atlantis ILIO is designed to reduce the amount of storage capacity required for desktop images, increase desktop performance, and increase the number of virtual desktops that can be run on a storage system. The Atlantis virtual appliance was installed on the Cisco UCS C-series server. Cisco and Atlantis recommend the following additional steps when using the ILIO appliance in a Cisco VXI environment:

1. Use the default settings configured during the Atlantis ILIO installation. These settings determine how and when the cache flushes data to disk and have been tuned for optimal performance.

2. Using the vSphere interface, make the following changes to the ESXi host that is running the Atlantis ILIO virtual appliance. See the ESXi Advanced Settings under the Configuration tab:

NFS.HeartbeatFrequency = 12 NFS.HeartbeatTimeout=5 NFS.HeartbeatDelta=8 NFS.HeartbeatMaxFailures=10

3. Ensure that the ESXi server has a VMK interface in the same VLAN as the ILIO management port so that the ILIO NFS traffic stays within the host and never touches the network.

Cisco Nexus 1000v The Cisco Nexus 1000V is an NX-OS based virtual access software switch that runs on VMware vSphere. The switch was overlaid across the UCS Series servers used for Cisco VXI system testing to enable virtual machine networking. The Cisco Nexus 1000V provides Layer 2 switching, advanced

Page 28: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 24

networking functions (such as QoS and security), and a common network management model in a virtualized server environment by replacing the virtual switch within VMware vSphere. The Cisco Nexus 1000V has the following components:

• The Virtual Supervisor Module (VSM)— the control plane of the switch and a virtual machine that runs NX-OS.

• The Virtual Ethernet Module (VEM) —a virtual line card embedded in each VMware vSphere (ESX) host. The VEM is partly inside the kernel of the hypervisor and partly in a user world process, called the VEM Agent. The VEM provides the data plane for the Cisco Nexus 1000v.

Installation of Cisco Nexus 1000v software is beyond the scope of this document. For detailed coverage of installation procedures, see the Cisco Nexus 1000V Software Installation Guide. Once the switch is successfully installed and its VM is powered on, a setup configuration dialog will automatically start. The Cisco Nexus 1000V can be configured by means of a Command Line Interface (CLI) or using a Graphical User Interface (GUI) tool. For a complete explanation of the entire configuration process, see the Cisco Nexus 1000V Configuration Guides. Essentials of a Cisco Nexus 1000V Series configuration include:

• Defining VEMs • Creating VLANs • Defining Port Profiles • Associating Port Profiles with Interfaces • Configuring the Connection between VSM and the VMware vCenter Server

VEMs A single instance of the Cisco Nexus 1000V can support up to 64 VEMs as well as a maximum of two VSMs (deployed in active/standby mode), creating the equivalent of a 66-slot modular switch. Each VEM needs to be configured with the VMware ID of the host with which it is associated. In the following example, each VEM is associated with a slot number and a host.

vem 3 host vmware id e87a619a-ee71-11df-0000-00000000025e vem 4 host vmware id e87a619a-ee71-11df-0000-00000000022e vem 5 host vmware id e87a619a-ee71-11df-0000-00000000023e vem 6 host vmware id e87a619a-ee71-11df-0000-00000000020e vem 7 host vmware id deed2b71-29ec-11df-b019-8843e138e566

VLANs For Cisco VXI validation, VLANs were used to logically separate traffic according to function as shown below. VLANs also can be used in system port profiles for VSM-VEM communications, uplink port profiles for VM traffic, and data port profiles for VM traffic. The following example shows a series of

Page 29: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 25

VLAN definitions. VLAN 1 is the default assignment; interfaces and ports not specifically assigned to other VLANs are members of VLAN 1.

vlan 1 vlan 34 name SONC-ESX-SRVR-MGMT vlan 35 name SONC-ESX-SRVR-VMOTION vlan 36 name SONC-PVS vlan 46 name VSG-Data vlan 47 name VSG-HA vlan 56 name SONC-MS-VM vlan 58 name SONC-CT-VM vlan 60 name SONC-VW-VM vlan 132 name SONCS-Infra-Servers vlan 144 name NFS vlan 146 name iSCSI

Port Profiles A port profile is a collection of interface-level configuration commands that are combined to create a complete network policy. A port group is a representation of a port profile on the vCenter server. Every port group on the vCenter server is associated with a port profile on the Cisco Nexus 1000V. Port profiles are created on the VSM and propagated to VMware vCenter Server as VMware port groups using the VMware VIM API. After propagation, a port profile appears within VMware vSphere Client and is available to apply to the vNICs on a virtual machine. The following examples show typical Cisco VXI configurations for both uplink and VM access ports. The uplink port profile defines this port as a trunk port, meaning that it can accommodate traffic from multiple VLANs. The VLANs that can use this trunk are specifically listed. The mtu is set to 9000 to support jumbo frames.

port-profile type ethernet Uplink-Port-Channel vmware port-group switchport mode trunk switchport trunk allowed vlan 34-36,46-47,58,60,132,144,146 mtu 9000 channel-group auto mode on mac-pinning no shutdown system vlan 34,144,146 state enabled

The next example shows a typical configuration for an access port. This profile defines an access port dedicated to VM traffic. As an access port, it only supports a single VLAN (vlan 58). A maximum of 1024 ports can be assigned to this profile.

port-profile type vethernet VM-58-Citrix vmware port-group switchport mode access

Page 30: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 26

switchport access vlan 58 no shutdown max-ports 1024 state enabled

Interfaces All interfaces on the Cisco Nexus 1000V are Layer 2 Ethernet interfaces. These interfaces can be configured as access ports, trunk ports, private VLANs, or promiscuous ports. Virtual Ethernet interfaces are logical interfaces, which correspond to virtual ports in use on the distributed switch. The following Cisco VXI example shows a Virtual Ethernet interface that inherits the characteristics of port profile VM-58-Citrix, and is associated with Network Adapter 1.

interface Vethernet115 inherit port-profile VM-58-Citrix description AS732MAWEBEX-AE,Network Adapter 1 vmware dvport 4641 dvswitch uuid "04 a7 09 50 7a a7 4a 56-37 12 5c de 0a 49 67 b5" vmware vm mac 0050.5689.0238

Connecting the VSM and VMware vCenter Server It is necessary to configure a connection to the vCenter Server in the Cisco Nexus 1000V. Prerequisites include having registered the Cisco Nexus 1000V plug-in on the vCenter Server, and knowing the server’s IP address, DNS name, and data center name. The example shows a connection configured between the switch and the vCenter Server at 10.0.132.16 port 80. The connection uses the VIM protocol.

svs connection SONC-VCenter protocol vmware-vim remote ip address 10.0.132.16 port 80 vmware dvs uuid "04 a7 09 50 7a a7 4a 56-37 12 5c de 0a 49 67 b5" datacenter-name SONC connect

The Cisco Nexus 1000V also provides the foundation for running other virtualized appliances such as the Cisco Virtual Security Gateway (VSG) and Cisco vWAAS. The following changes were made on the Nexus 1000v port profile configuration to forward virtual desktop traffic to the VSG and vWAAS virtual applicance hosted services using vPath: port-profile type vethernet VM-60-WebVSG vmware port-group switchport mode access switchport access vlan 60 org root/Sit_ORT ip verify source dhcp-snooping-vlan vn-service ip-address 10.0.46.5 vlan 46 fail open security-profile SP_HVD no shutdown max-ports 1024 state enabled port-profile type vethernet VM-60-View-VM-vWAAS vmware port-group switchport mode access switchport access vlan 60

Page 31: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 27

vn-service ip-address 10.0.132.40 vlan 132 fail open no shutdown state enabled The complete Nexus 1000v configuration can be found here : Nexus1000v Configuration.

Cisco Virtual Security Gateway Cisco Virtual Security Gateway for Cisco Nexus 1000v Series switches is a virtual appliance that controls and monitors access to trust zones in enterprise and cloud provider environments. Cisco VSG provides secure segmentation of virtualized data center VMs using granular, zone-based control and monitoring with context-aware security policies. VSG works in unison with Nexus 1000v and is managed using VNMC console. During the Cisco VXI validation, VSG was used to segment knowledge workers from task workers. Appropriate communication ports for display protocols, Active Directory, Internet access, etc. were allowed from each zone. Further, inter-zone and intra-zone communications are denied. Cisco VSG was deployed in the data center and used vPath interception on Nexus 1000v to intercept and secure traffic. The attached configuration files layout the VNMC configuration in relation with the CLI configuration seen on the VSG. A successful VSG setup requires communication between VNMC and vCenter, VNMC and N1K switch and finally VNMC and VSG itself to be established. The configuration required is listed in the VNMC-VSG file is listed. Further zoning in a VXI environment is done base don VM attributes and Virtual Desktops belonging with similar functions/privileges are placed in the same zone. The configuration required for zoning is covered in detail in VNMC VSG configuration document along with screen shots. All zones must have rules defined to allow incoming Desktop protocol traffic and communications between the virtual desktops and the infrastructure components such as Brokers, Active Directory, Hypervisor manager etc. The definition of these rules along with appropriate port numbers for infrastructure communications is described in the configuration files below. The VNMC configuration screenshots can be found here : VNMC VSG Configuration. The complete Virtual Security Gateway configuration can be found here : VSG Configuration.

Cisco vWAAS The Cisco vWAAS is a virtual appliance that accelerates business applications delivered from private and virtual private clouds. Cisco vWAAS runs on Cisco UCS servers with supported hypervisors, using the policy-based configurations in the Cisco Nexus 1000v switch. Cisco vWAAS was deployed in the data center and used vPath interception on Nexus 1000v to intercept and optimize traffic. VXI traffic specific classifiers need to be set as described in the Branch configurations below. Apart from the VXI classifiers and wccp configurations all the remaining configuration is standard. The complete Cisco vWAAS configuration can be found here : vWAAS configuration.

Page 32: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 28

McAfee MOVE-AV McAfee Optimized Virtual Environments - Antivirus for VDI (MOVE-AV for VDI) was used to provide a scalable centralized virus protection solution. A highly optimized and dedicated virus scan server cluster does the resource intensive work of scanning the virtual desktop files, thereby significantly increasing the virtual desktop density achievable. The MOVE-AV was deployed using default scan settings with redundant Virus Scan Engines (VSE) co-located on the same virtual switch as the virtual desktops.

Hypervisor Installation and Configuration

VMware ESX/ESXi In this test The VMware ESX/ESXi hypervisor was installed on the servers. Version 4.1 was tested. The vSphere/vCenter management suite was used to manage the hypervisor. In the Cisco VXI validated design testing, hosts were organized into a single cluster to enable HA features like DRS and vMotion which provide higher availability when blades power down or fail (due to power failure or upgrade ). It is recommended to cluster hosts across different UCS chassis enclosures to provide better availability in event of a chassis failure. Management and infrastructure server applications (including the Nexus 1000v VSM) were installed on a dedicated UCS blade. A dedicated database server is used to host the vCenter and VMware View databases. The vSphere Enterprise Plus License was deployed on the vCenter server. It is recommended to use the Update Manager tool to install the latest ESXi patches on the blade. The Nexus 1000v virtual distributed switch was used to provide network connectivity to the virtual machines hosted across multiple UCS blades running ESX/ESXi. It was deployed with redundant Virtual Switch Modules (VSM). It was provisioned with VLANs, port profiles, and port channel groups using the NX-OS CLI. Virtual port groups assigned to a dedicated VLAN were used to segment the traffic for Citrix XenDesktop desktops, View desktops, VSG, NFS, PVS, vWAAS, and infrastructure servers. NAS and SAN based datastores connected via NFS and FC protocol connections were provisioned to store the virtual machine vmdk files. Path redundancy with load balancing was used to connect to the SAN storage devices. Virtual Desktops were provisioned with a guest OS running Windows 7 32-bit, Windows 7-64-bit, Windows XP with 1.5GB or 2GB RAM and 24GB of disk space. The ESX/ESXi and vCenter configuration screenshots can be found here : vSphere configuration.

Micros oft Hyper-V In this test the Microsoft Hyper-V hypervisor was installed on the servers. The server core installation of Windows 2008 R2 64-bit was used to implement Hyper-V. The Microsoft System Center Virtual Machine Manager (MSCVMM) and Hyper-V Manager was used to manage the hypervisor. In the Cisco VXI validated design testing, the Microsoft virtual switch was used to provide network connectivity to the virtual machines hosted on the UCS blades running Hyper-V. NAS and SAN based datastores connected via NFS and FC protocol connections were provisioned to store the virtual machine

Page 33: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 29

files. Virtual Desktops were provisioned with guest running Windows 7-64-bit (2GB of RAM) and Windows XP (with 1GB RAM) and 20GB of disk space. The MSCVMM was used to manage the Hyper-V environment and adds features not available in Hyper-V Manager like live migration and library management (ie. templates). The Hyper-V and MSCVMM configuration screenshots can be found here : Hyper-V Configuration.

Desktop Virtualization Software Installation and Configuration

VMware View Configura tion In this test VMware View 4.5/4.6 was installed to provide DV services to end users. The VMware View Composer 2.5 was used to provision the hosted virtual desktop pools. In the Cisco VXI validated design testing, the vSphere/vCenter connection details were provisioned in the View Manager Administrator console. Separate desktop pools were created for Windows 7 32-bit, Windows 7 64-bit, Windows XP desktops. These were automated pools so that desktops are generated based on a golden image. (ie. virtual machine snapshot). The golden image included the standard office productivity applications in addition to the UC application suite and the McAfee MOVE-AV agent. The pools used dedicated entitlements so that the user always gets the same desktop. The desktop pools used the View Composer Linked-clone feature so that the desktops share the same base golden image and storage disk space is conserved. The linked clones and replica (golden read-only image) were stored on different storage devices with different memory overcommit policies for better storage performance in some test configurations. In these configurations, the replica was stored on faster read-only storage. All desktops were set to be powered up all the time and refreshed after user logout. Please refer to the configuration screen shots for the detailed pool settings used. The users Windows profiles were redirected to a persistent disk and temporary files are stored on non-persistent storage. The user entitlement for the desktop pools were specified as an Active Directory group of users. The VMware View configuration screenshots can be found here : VMWare View Configuration.

Citrix XenDes ktop Configura tion In this test Citrix XenDesktop 5.0 was installed to provide DV services to end users. The Citrix Desktop Studio was used to provision the hosted virtual desktop pools. In the Cisco VXI validated design testing, the vSphere, SCVMM, or XenCenter connection details were provisioned in the XenDesktop Studio console. Separate desktop groups were created for Windows 7 32-bit, Windows 7-64-bit, Windows XP desktops. The desktop catalog used pooled machines that were generated based on a golden image snapshot. The golden image included the standard office productivity applications in addition to the UC application suite and the McAfee MOVE-AV agent. The desktop catalog used random assignment so that the user is assigned a desktop in a random manner. The desktop catalog uses Citrix Provisioning Services so that the desktops share the same base golden image and storage disk space is conserved. The user assignment for desktop groups was specified as an Active Directory group of users. Refer to the configuration screen shots for the detailed desktop group settings used. The Citrix XenDesktop configuration screenshots can be found here : Citrix XenDesktop Configuration.

Page 34: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 30

Page 35: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 31

Data Center Networking Infrastructure Figure 8: Data Center Network Components

Cisco Nexus 5010 Access Layer Switch The Cisco Nexus 5010 Switch is a 1 Rack unit (RU), 10 Gigabit Ethernet/FCoE access-layer switch with 20 fixed 10 Gigabit Ethernet/FCoE ports that accept modules and cables meeting the Small Form-Factor Pluggable Plus (SFP+) form factor. One expansion module slot can be configured to support up to 6 additional 10 Gigabit Ethernet/FCoE ports, up to 8 Fibre Channel ports, or a combination of both. For larger server pods, the Cisco Nexus 5020 (2 RU and 40 fixed ports, plus to module slots) can be used. The Cisco Nexus 5010, in combination with the Cisco Nexus 1000v, provides the functions for the Data Center Access Layer. This test configuration consists of a pair of Cisco Nexus 5010. Four 10 GE uplinks are configured on each of the Cisco UCS Fabric interconnect and are connected to each Nexus 5010 in parallel. The upstream interfaces are connected to ports that belong to the Internal Virtual Device Contexts (VDCs) on the Cisco Nexus 7010. Nexus 5010 configuration for a VXI system is not any different from a typical data center, however a few key considerations for VXI are described below. Virtual Port Channel (vPC, LACP): Virtual port channels although not required are a highly recommended in a VXI setup. VPC creates etherchannels spanning multiple chassis and by turning off spanning tree protocol allow for all links to be in forwarding state, there by increasing the total bandwidth available to downstream devices. To enable vPC enable the lacp and vpc features as shown

Page 36: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 32

below and setup the management vrf. The two Nexus 5010 establish peer relationship over the management interface. No configurations or states are communicated over the management interface. feature lacp feature vpc interface mgmt0 ip address 10.0.32.8/24 vrf context management ip route 0.0.0.0/0 10.0.32.1 port-channel load-balance ethernet source-dest-ip invalid-hash vpc domain 200 peer-keepalive destination 10.0.32.9 source 10.0.32.8 The portchannel interface between the two 5010 is defined as a vpc peer-link. All switch states are exchanged over this interface along with data traffic. The port channel is configured as spanning tree network port by default when the portchannel is added to the vpc domain (the config below explicity configures the spanning-tree port type). interface port-channel10 switchport mode trunk vpc peer-link switchport trunk native vlan 999 switchport trunk allowed vlan 34-36,38-39,46,48,50,52,54,56,58,60,62,132,144,146,148,999 spanning-tree port type network speed 10000 All other portchannels and interfaces (not in portchannels) need to be added to appropriate vpc by issuing “vpc <#>” command. Vlan IDs and vpc numbers can be different but the vpc number are required to be consistent across both Nexus 5010 switches. interface port-channel20 switchport mode trunk vpc 20 switchport trunk native vlan 999 switchport trunk allowed vlan 34-36,38-39,46,48,50,52,54,56,58,60,62,132,144,146,148,999 speed 10000 Jumbo Frame: Jumbo frames need to be normally configured with Fibre channel, iScsi etc storage traffic and requires some configuration on the Nexus 5010. The QoS and System mtu configuration for jumbo frames is listed below. class-map type qos class-fcoe policy-map type network-qos jumbo class type network-qos class-fcoe pause no-drop mtu 2158

Page 37: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 33

class type network-qos class-default mtu 9216 system qos service-policy type network-qos jumbo Vlan should be created to separate hypervisor management, Virtual desktop, migration, storage etc. traffic. The VLAN assignment can be found in the complete configuration below. The complete Nexus 5010 configuration used during validation can be found here : Nexus 5010 Configuration.

Cisco Nexus 7010 The Cisco Nexus 7010 Switch is used in the collapsed module for both the Data Center Aggregation and Core layers. This is done by creating two Virtual Device Contexts (VDCs): Internal (connected to Hosted Desktops, Application Servers) and External (connected to Enterprise Core switches). The Internal VDC acts as the Aggregation layer. The External VDC acts like the Core Layer. Each VDC is isolated from the other for increased availability. Should one VDC encounter an error or crash, the other is not affected. The Nexus 7010s are installed as a redundant pair. The complete Nexus 7010 configuration can be found here: Nexus 7010 Internal Device Context Configuration and Nexus 7010 External Device Context Configuration.

Cisco Application Control Engine (ACE4710) The Cisco Application Control Engine (ACE4710) is used in the VXI environment to provide load balancing functions for the DV Connection Brokers. They are connected in a redundant pair to the Internal VDC on the Cisco Nexus 7010. Virtual contexts are created on the ACE for different test environments and each context included server farms for VMware View Desktops, the Citrix XenDesktops, and Microsoft Remote Desktops. The following configurations on the ACE implement health monitoring probes for the View Manager and XenDesktop Controller : probe https View-Web interval 15 faildetect 1 passdetect interval 30 passdetect count 2 receive 2 ssl version all expect status 200 200 open 1 probe http Xen-Web interval 15 faildetect 1

Page 38: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 34

passdetect interval 15 passdetect count 2 receive 2 expect status 200 200 open 1 The following configurations on the ACE setup the XenDesktop Controller server farm : rserver host XenCM1 ip address 10.0.132.11 inservice rserver host XenCM2 ip address 10.0.132.24 inservice serverfarm host XenCM probe Ping probe Xen-Web fail-on-all rserver XenCM1 inservice rserver XenCM2 inservice sticky ip-netmask 255.255.255.255 address source StickyXen timeout 5 serverfarm XenCM class-map match-all Xen-VIP 2 match virtual-address 10.0.60.36 any policy-map type loadbalance first-match Xen-LB class class-default sticky-serverfarm StickyXen policy-map multi-match Xen class Xen-VIP loadbalance vip inservice loadbalance policy Xen-LB loadbalance vip icmp-reply nat dynamic 1 vlan 132 interface vlan 60 service-policy input Xen no shutdown The complete Cisco ACE4710 configuration can be found here : ACE Configuration.

Page 39: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 35

Cisco Adaptive Security Appliance (ASA5580) The Cisco Adaptive Security Appliance installed in the Data Center provides firewall services to isolate and protect the various compute resources from both external traditional desktop users as well as the DV users installed in the data Center. Two virtual contexts are used on the ASA : Non Server (connected to VRF for Hosted Desktops) and Server (connected to VRF for Application Servers). The ASA5580s are deployed as a redundant pair (configured in active-active mode ) and are connected to the Internal VDC and External VDC on the Cisco Nexus 7010. Use the ASDM or the ASA CLI to provision security services on the ASA. The following configuration on the ASA provisions services ( UC and Virtual Desktop services ) and hosts to be allowed through the firewall : object-group service UC-SERVICES group-object JABBER group-object RTP group-object SCCP group-object SIP group-object WEB-SERVICES service-object tcp destination range 1101 1129 service-object tcp destination eq 2444 service-object tcp destination eq 2749 service-object tcp destination eq 3223 service-object tcp destination eq 3224 service-object tcp destination eq 3804 service-object tcp destination eq 4321 service-object tcp destination eq 61441 service-object tcp destination eq 8007 service-object tcp destination eq 8009 service-object tcp destination eq 8111 service-object tcp destination eq 8222 service-object tcp destination eq 8333 service-object tcp destination eq 8404 service-object tcp destination eq 8444 service-object tcp destination eq 8555 service-object tcp destination eq 8998 service-object tcp destination eq 9007 service-object tcp destination eq 9009 service-object tcp destination eq ctiqbe group-object LDAP group-object TFTP group-object IMAP object-group service ICA - desktop protocols service-object tcp destination eq 1604 service-object tcp destination eq 2598 service-object tcp destination eq citrix-ica

Page 40: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 36

object-group service PCOIP service-object tcp destination eq 32111 service-object tcp destination eq 4172 service-object tcp destination eq 50002 service-object udp destination eq 50002 service-object udp destination eq 4172 object-group service RDP service-object tcp destination eq 3389 object-group service DESKTOP-SERVICES group-object ICA group-object RDP group-object PCOIP access-list allowall extended permit object-group UC-SERVICES object-group ALL-HOSTED-DESKTOPS object-group UC-SERVERS Similarly, hosts and services in the network like hypervisor managers and desktop connection managers should also be provisioned. Use the following configuration on the ASA to enable jumbo frames : mtu outside 9216 Used for Jumbo Frames mtu inside 9216 Configure the global policy to enable application layer inspection by the ASA : policy-map global_policy class inspection_default inspect waas It is important to add ‘inspect waas’ to allow vWAAS traffic through the ASA. Otherwise vWAAS traffic will be blocked going through the ASA. The complete Cisco ASA 5580 configuration can be found here : ASA Server Configuration and ASA Non Server Configuration.

Cisco WAN Acceleration Engine (WAE-512) The WAE-512s installed in the data center are the controllers for the other WAAS appliances installed in both the campus and branch networks. They are installed as a redundant pair. The complete Cisco WAE-512 configuration can be found here : WAAS Controller Configuration.

Cisco Network Analysis Module (NAM2220)

Page 41: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 37

The Cisco NAM2220 is used to monitor and collect data on traffic flow entering and leaving the data center. This tool is useful for monitor the DV users load on the network and identifying any potential bottlenecks in the design. A SPAN port created on the Internal VDC on the Nexus 7010 was used to monitor and capture traffic. The NAM appliance was also used to collect Netflow data exported from the campus network routers and switches. The complete Cisco NAM2220 configuration can be found here : Network Analysis Module Configuration.

Campus Network The campus network is composed of two redundant Catalyst 6504E switches, Branch Connectivity routers, internet access routers, WAN accelerators, and Firewall Appliances. It also contains equipment for local campus access. Figure 9: Campus Network Components

Page 42: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 38

Cisco Catalyst 6504E (CAT6504E) The Cisco CAT6504E switches are used for the core and distribution layer functions for the campus network. They are installed uplinked to the data center Nexus 7010 which provides the data center core functions. These switches are installed as a redundant pair. The complete Cisco CAT6504E configuration file can be found here : Catalyst 6504 configuration.

Cisco 7206VXR Router The Cisco 7206VXR routers are used to provide branch connections that do not require VPN services. The complete Cisco 7206VXR configuration can be found here : 7206VXR Configuration.

Cisco WAN Acceleration (WAE-674) The Cisco WAE-674s installed in the campus network provide the campus-side termination of the WAAS tunnels from the branch WAE appliances. Some key classifiers and mapping need to be configured for VXI are listed below. Note that since PCoIP traffic is over UDP transport WAAS is unable to optimize the traffic and hence no configuration is required. Other WAAS configuration parameters still need to be configured to enable optimization and these are covered in the complete comfiguration below. policy-engine application name Remote-Desktop

Page 43: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 39

classifier Citrix-ICA match dst port eq 1494 match dst port eq 2598 exit classifier HTTP match dst port eq 80 match dst port eq 8080 match dst port eq 8000 match dst port eq 8001 match dst port eq 3128 exit classifier HTTPS match dst port eq 443 exit map basic name Remote-Desktop classifier Danware-NetOp action optimize DRE no compression none name Remote-Desktop classifier Laplink-surfup-HTTPS action optimize DRE no compression none name Remote-Desktop classifier Remote-Anything action optimize DRE no compression none The complete Cisco WAE-674 configuration file can be found here : WAE-674 Configuration.

Cisco Adaptive Security Appliance (ASA5540) The Campus Cisco ASA5540 network provides a VPN concentrator for the Cisco AnyConnect Clients. The complete Cisco ASA 5540 configuration can be found here : ASA Configuration.

Cisco Integrated Service Router (ISR3945) The Campus Cisco ISR3945 provides the VPN concentrator for site-to-site network connections. The complete Cisco ISR3945 configuration can be found here : 3945 Configuration.

Cisco Catalyst 4500E (Campus Access CAT4500E) This Catalyst 4500E provides the campus user access to the network with PoE+ It contains the L2 edge features such as QoS, Security, and Energywise. The complete Catalyst 4500E configuration file can be found here : Catalyst4500E Configuration.

Cisco Catalyst 4507E (Campus Access CAT4507E)

Page 44: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 40

The Catalyst 4507E provides alternate method for campus user access to the network. It contains the L2 edge features such as QoS and Security. The complete Cisco Catalyst 4507E configuration can be found here : Catalyst 4507E Configuration.

Cisco Aironet Access Points Cisco Aironet IEEE 802.11a/b/g wireless access points provide a wireless method for campus users to access to the network using mobile devices like laptops and tablets. They have the versatility associated with connected antennas, a rugged metal enclosure, and a broad operating temperature range. In this test, the Aironet 1140 and 1240 series of access points were used in the branches and Aironet 1250, 1260, 3502e, and 3502i series of access points were used in the campus network. The Cisco Aironet access points are configured by the Cisco Wireless Controller.

Cisco 5508 Wireless Controller The Cisco 5508 Wireless Controller (WLC) controls and manages the Cisco Aironet wireless access points deployed in the campus and branch networks. It offers enhanced uptime with RF visibility and CleanAir protection and reliable streaming video and voice quality. The complete WLC configuration can be found here : WLC Configuration.

Cisco 3310 Mobility Services Engine The Cisco 3310 Mobility Services Engine (MSE) provides mobility services and applications across a variety of mobility networks. It provides location based services for wired and wireless VXI endpoints. Refer to Appendix 1 for guidance in provisioning the MSE for location tracking services.

Branch Configurations All branches use the same configuration for the Catalyst 3560 and 3750. The complete Catalyst 3560 configuration can be found here : 3560 Branch Configuration. All branches use either a Cisco Aironet 1131AG or 1242AG access point to provide wireless network access to users. All branches included the VXC clients : VXC-2211/2212 and VXC-2111/2112 which allow users to access their virtual desktop. Refer to the VXC client documentation for guidance on provisioning the VXC clients.

Branch 1 – Branch connection with PfR This branch configuration uses a Cisco ISR3845 router, a Cisco Catalyst 3560 switch, and a Cisco Aironet 1242AG access point. The ISR was tested with both T1 and T3 connections. The 3845 was configured with the Performance Routing (PfR) feature enabled which provides path optimization and

Page 45: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 41

advanced load balancing for VXI traffic over the WAN. The complete Branch 1 configuration can be found here : 3845 Branch 1 Configuration. Figure 10: Branch 1 Design

Branch 1 design focuses on validating PfR in VXI environment. PfR operation has multiple steps, traffic classification, network characterstics measurement, policy identification and policy enforcement. All branch routers enabled with PfR work as border routers and communicate with the master router. The configuration for PfR used is listed below with appropriate explanations. key chain PFR_Chain key 1 key-string cisco_123 pfr master policy-rules POLICY2 logging ! Identify the interfaces included in the PfR operations and attach the key string defined above for communications with the master. border 10.1.253.5 key-chain PFR_Chain interface Serial0/0/1 external interface Serial0/0/0 external interface Loopback1 internal interface GigabitEthernet0/0 internal ! Define network characterstics to measure for PfR operation. In this case throughput and delay are being measure and will be used as inputs for policy enforcement. learn

Page 46: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 42

throughput delay periodic-interval 1 monitor-period 1 prefixes 250 applications 250 list seq 10 refname MYLIST traffic-class access-list PFR_list delay delay threshold 30 <Delay threshold defined here defines out-of-policy triggers. mode route control mode monitor passive <Passive monitoring measures TCP throughput from live traffic. For UDP traffic active ping probes are required> mode select-exit best resolve delay priority 1 variance 5 <The amount of delay variance defines the acceptable jitter> ! active-probe echo 10.1.253.5 <Active probes are sent to the master and network health is measured directly> active-probe tcp-conn 10.1.253.5 target-port 2000 ! For active probing it is recommended to use a loopback interface. pfr border local Loopback1 master 10.1.253.5 key-chain PFR_Chain active-probe address source interface Loopback0 crypto pki token default removal timeout 0 Classify PfR traffic using a standard ACL. IN this scenario all traffic was VXI specific so a port numbers were not used. In scenarios where PfR is applied for specific traffic types port numbers can be used to classify applications. ip access-list extended PFR_list permit tcp any 10.1.1.0 0.0.0.255 permit tcp 10.1.1.0 0.0.0.255 any permit ip any 10.0.0.0 0.0.0.255 ! ip sla responder ip sla responder tcp-connect port 2000 pfr-map BLUE 10 match pfr learn delay set mode select-exit best set delay threshold 90 ! pfr-map test1 10 ! pfr-map POLICY2 10

Page 47: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 43

match pfr learn list MYLIST set delay threshold 30 ! pfr-map POLCY2 10 set resolve delay priority 1 variance 1

Branch 2 – Branch connection with external WAVE-674 This branch configuration uses a Cisco ISR3845 router, a Cisco Catalyst 3750 switch, and a Cisco Aironet 1131AG access point. The ISR was tested both T1 and T3 connections. The WAVE-674 is connected via an Ethernet port on the ISR3845. The ISR3845 in Branch 2 uses WCCP redirection for connection to the WAVE-674. Refer to the Appendix 3 for specific guidance on implementing a QOS policy for traffic traversing the WAN. Traffic to external WAAS appliance from the branch router is redirected using WCCP option 61 on every incoming traffic interface on the router except where WAE is connected. On all incoming router interfaces wccp command shown below is used to redirect traffic to WAE. ip wccp 61 redirect in Interface connecting directly to WAAS interface need to be excluded from wccp using the command below. This avoids sending the optimized traffic back into the waas appliance avoinding loops. ip wccp redirect exclude in The complete Branch 2 configuration can be found here : 3845 Branch 2 Configuration and WAVE-674 Configuration. Figure 11: Branch 2 Network Design

Page 48: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 44

Branch 3 – Branch connection with no WAAS This branch configuration uses a Cisco ISR3845 router, a Cisco Catalyst 3560 switch and a Cisco Aironet 1242AG access point. The ISR was tested with both T1 and T3 connections. The complete Branch 3 configuration can be found here : 3845 Branch 3 Configuration Figure 12: Branch 3 Network Design

Branch 4 – Branch connection with WAAS SRE Module This branch configuration uses a Cisco ISR2951 router, a Cisco Catalyst 3750 switch and a Cisco Aironet 1242AG access point. The ISR was connected via both T1 and T3 connections. The configuration may only show one of the serial connections active. The WAAS SRE module operates the

Page 49: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 45

same as an external device. The ISR still uses WCCP redirection for this application; however the network connection to the SRE module is made internal to the ISR. The complete Branch 4 configuration can be found here : 2951 Branch 4 Configuration and WAAS SRE Configuration. Figure 13: Branch 4 Network Design

Branch 5 – Identical to Branch 3 except uses 3945

Branch 6 – Branch connection with WAAS Express This branch configuration uses a Cisco ISR3945 router, a Cisco Catalyst 3750 switch and a Cisco Aironet 1131AG access point. The ISR was connected via both T1 and T3 connections. The WAAS Express feature is enabled on the 3945. The complete Branch 6 configuration can be found here : 3945 Branch 6 Configuration. Figure 14: Branch 6 Network Design

Page 50: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 46

Branch 7 – Identical to Branch 3 except uses 3945

Branch 8 – Identical to Branch 3 except uses 2951

Branch 9 – Direct Connection using Site-to-Site VPN This branch configuration uses a Cisco ISR3945 router, a Cisco Catalyst 3560 switch and a Cisco Aironet 1242AG access point. While the hardware is the same as Branch 1, the configuration is the different. This ISR connects via a Site-to-Site VPN tunnel to the Campus ISR3945. The complete Branch 9 configuration can be found here : 3945 Branch9 Configuration. Figure 15: Branch 9 Network Design

Page 51: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 47

Branch 10 – Direct Connection using AnyConnect VPN This branch configuration uses a Cisco 7301 router, a Cisco Catalyst 3560 switch and a Cisco Aironet 1242AG access point. This ISR connects using AnyConnect VPN to the Campus ASA5540. The complete Branch 10 configuration can be found here : 7301 Branch10 Configuration. Figure 16: Branch 10 Network Design

Appendix 1 – Location Tracking Location Tracking

Location tracking for Cisco VXI requires the following minimums

Catalyst 4K Switch IOS version 12.2(52)SG or later.

Catalyst 3K Switch IOS version 12.2(50)SE or later.

MSE 3355 – Recommended for large scale deployments to track up to 18,000 endpoints

MSE 3310 – Recommended for smaller VXI deployments of upto 2000 devices.

Currently VXI environment can only leverage the admin tag and civic information stored on the switches. Admin tag is an administrative tag or a site location associated with a logical grouping of devices or users.

The civic location is a string which usually denotes the various elements of a civic location as described in RFC 4776. An example of a civic location as configured in the switch is as follows: Switch(config)# location civic-location identifier 1 Switch(config-civic)# number 3550 Switch(config-civic)# primary-road-name "Cisco Way" Switch(config-civic)# city "San Jose" Switch(config-civic)# state CA Switch(config-civic)# building 19 Switch(config-civic)# room C6 Switch(config-civic)# county "Santa Clara"

Page 52: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 48

Switch(config-civic)# country US Switch(config-civic)# end

Note The labels such as “building”, “room”, “state” etc are defined element types in the RFC. The rest of the string that follows is the value configured for that label.

Configuration sequence – Wired Switch

The switch has to be configured for the location service. This includes configuration of location data as well as enabling NMSP. These are the configuration steps on the switch side:

• Understand the Slot/Module/Port configuration (1/0/20).

• Use the correct IOS version that pertains to the respective switch model

• Enable the NMSP.

• Enable the IP Device tracking.

• Configure the SNMP community with read-write access.

• Configure the Civic/admin tag location identifiers.

• Assign identifiers to the switch interfaces.

CLI commands for the above sequence and other useful debug information can be found at:

Configuration sequence – for WCS. Required for wired switches to relay location information to the WCS.

http://www.cisco.com/en/US/docs/switches/lan/catalyst3750/software/release/12.2_50_se/configuration/guide/swlldp.html

On the WCS:

• Go to Configure >Ethernet Switches.

• Add Ethernet switches.

• Add the IP address.

• Enable Location Capable.

• Enter the SNMP Community (read-write). The SNMP community string entered must match that value assigned to the Catalyst switch.

• Go to Services > Synchronize Services > Switches.

• Click Assign to assign it to preferred MSE.

• Choose the switch and synchronize.

• Go to Services > Synchronize Services > Switches.

• Go to System > Status > NMSP Connection status.

• Check for the active NMSP status for each switch.

Once both configuration sequences above are complete wired elements can be viewed on the WCS:

• Under Context Aware Services, click Wired Switches under Wired

• A list of the switches displays.

• Click Switch IP Address to view details

Detailed configuration steps and screen shots for Location based services, also called context-aware-services can be found at.

http://www.cisco.com/en/US/partner/products/ps9742/products_installation_and_configuration_guides_list.html

http://www.cisco.com/en/US/partner/docs/wireless/mse/3350/7.0/CAS/configuration/guide/CAS_70.html

Page 53: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 49

Appendix 2 - Endpoint security 802.1x, MacSec, MAB, ACS

Configuration sequences below are built based on the discussion in the Release 2.0 VXI CVD. Please see Deployment and Configuration best practices of VXI security components section under Anyconnect 3.0, Dot1x, MacSec and MAB along with ACS. The configuration sequence below is an sample scenario and not part of the validated architecture. It is presented here as a reference to understand configuration sequence of various elements involved in securing the VXI Access.

Following procedure should be used to setup Anyconnect, Dot1x, ACS5.2 and MacSec in VXI environment.

1. Any Connect 3.0 Network Access Manager (NAM) Configuration

In this section, the AnyConnect NAM Profile Editor is used to create an example wired 802.1x connection that is MACsec enabled. Before starting Launch the profile editor

Client Policy Configuration : Defines the options that govern the client policy.

Step 1 From the left navigation menu, select Client Policy

Step 2 Select Enable for the Service Operation under Administrative Status.

Step 3 Select Attempt connection after user logon for Connection Settings

Step 4 Under Mediacheck Allow Wired (802.1x) Media, and Allow user to disable client

Note MACsec is only supported on wired media.

Authentication Policy Configuration:

Define the global association and authentication policies. This policy controls what type of networks the end user may create using the AnyConnect UI. Launch the Network menu and enable all options. Depending on the enterprise policy some options may be disabled as needed.

Network Configuration:

AnyConnect 3.0 is configured for use on a wired network that supports 802.1x authentication and MACsec encryption. From the Anyconnect UI on the Anyconnect profile editor follow the procedure below. This is a onetime procedure for each type of profile and is recommended to be distributed via ASA.

Step 1 Click Add.

Step 2 Enter a Name for the connection (MACsec for example) and select Wired (802.3) Network

Step 3 At the bottom of the window, click Next

Step 4 Under Security Level, select Authenticating Network

Step 5 Within the Security section, set Key Management to MKA and Encryption to MACsec AES-GCM-128

Step 6 Within the Port Authentication Exception Policy, select Dependent on 802.1x. In this example the switch is configured for 'must secure' so therefore none of the port exceptions under 'Dependent on 802.1x' need to be checked.

Step 7 Click Next

Step 8 Under Network Connection Type, select User Connection.

Page 54: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 50

Note MACsec encryption is supported for Machine and User Connections. However, in this example only User Connection is selected

Step 9 ClickNext

Step 10 Within EAP methods, select PEAP

Note In this example PEAP is used for authentication however MACsec encryption is supported with any EAP method that generates a Session-Id (See RFC5247) including EAP-TLS, EAP-PEAP, and EAP-FAST.

Step 11 Click Next

Step 12 Within User Credentials, select Prompt for Credentials

Step 13 Click Done.

Step 14 Navigate to the menu options in the upper left corner of the Profile Editor. Choose File -> Save. Save the file as "configuration.xml".

Deploy this profile via the ASA, please refer to Chapter 2, "Deploying the AnyConnect Secure Mobility Client", of the Cisco AnyConnect Secure Mobility Client Administrator Guide.

2. Configuring the 3750-X/3560-X switch with Dot1X and MacSec

Base AAA Configuration: Base configuration for AAA (RADIUS). The configuration described below is required to enable 802.1X authentication: CTS-3750X(config)#aaa new-model CTS-3750X(config)#aaa authentication dot1x default group radius CTS-3750X(config)#aaa authorization network default group radius CTS-3750X(config)#aaa accounting dot1x default start-stop group radius CTS-3750X(config)#radius-server host <ip address> auth-port 1812 acct-port 1813 key cisco123 CTS-3750X(config)#radius-server vsa send authentication CTS-3750X(config)#radius-server vsa send accounting

Note The command "aaa authorization network" is required for authorization methods such as dynamic VLAN assignment or downloadable ACL.

802.1x and MACsec Configuration: Enable 802.1X in global configuration mode CTS-3750X(config)#dot1x system-auth-control

Enable 802.1X on interface CTS-3750X(config)#int gi1/0/1 CTS-3750X(config-if)#switchport mode access CTS-3750X(config-if)#authentication port-control auto CTS-3750X(config-if)#dot1x pae authenticator

Enable MACsec on interface CTS-3750X(config-if)#mka default-policy CTS-3750X(config-if)#macsec CTS-3750X(config-if)#authentication linksec policy CTS-3750X(config-if)#authentication event linksec fail action next-method CTS-3750X(config-if)#authentication event linksec fail action authorize VLAN

3. Configure 802.1x Components in ACS: 802.1x policy elements, Identity Stores, Access Services and Access Service Selection are configured on ACS.

Page 55: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 51

Configuring Identity Stores and an Identity

Step 1 In the left column, under Users and Identity Stores, select Identity Store Sequences and select Create.

Step 2 Enter a name (in this example the name is "802.1x Identities"). Select the check box for Password Based authentication method, and then add Internal Users to the Selected section. Click Submit.

Step 3 In the left navigation column, under Users and Identity Stores, expand Internal Identity Stores, and select Users. Click Create.

Step 4 Enter a username. Enter and confirm a password under Password Information. Click Submit when done.

Create an Authorization Profile: Creating a wired authorization profile. This profile is used to define users access to the network.

Step 1 In the left navigation column, under Policy Elements, expand Authorization and Permissions. Then expand Network Access and select Authorization Profiles. Click Create.

Step 2 On the General tab, specify a name for this profile.

Step 3 Click on the Common Tasks tab. Navigate down to 802.1x-REV. Select a Static value of "must-secure".

Note This linksec policy will override the policy configured on the interface

Step 4 Click Submit.

Create a 802.1x Access Service

Step 1 In the left navigation column, under Access Policies, click Access Services.

Step 2 At the bottom of the resulting pane, click Create.

Step 3 Specify a name to for this service.

Step 4 Under Access Service Policy Structure, choose Based on service template, and then click Select.

Step 5 Choose Network Access-Simple and click OK. Then click Nextat the bottom of the resulting window.

Step 6 No need to change any settings in this window*. * Click Finish. You will be prompted to modify the service selection policy. Click No.

Define the Authorization Policy: Here the authorization policy of the access service is defined.

In the left navigation column, under Access Policies navigate to the access service that was just created. (802.1x Service in this example).

Step 1 Expand 802.1x Service and click Authorization. Click Create.

Step 2 Specify a name for the rule

Step 3 Under Conditions, choose NDG:Location and click Select. Set the value to All Locations.

Step 4 Scroll down to the Results section and click Select. An Authorization Profiles dialog box appears:

Step 5 Select the Finance 802.1x Authz profile that was created in Create an Authorization Profile section.

Page 56: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 52

Step 6 Click OK. Click Save Changes.

Create a Service Selection Rule: Creating a service selection rule. This rule ensures the policies defined in an access service (802.1x Service in this example) are applied to 802.1x requests.

Step 1 In the left navigation menu, under Access Policies, click Service Selection. At the bottom of the right pane, click Create.

Step 2 Specify a name for the rule (Match 802.1x Requests is used here)

Step 3 Select Protocol and match it with Radius.

Step 4 Select Compound Condition. Under Condition, choose RADIUS-IETF for Dictionary and Service-Type for Attribute. For Value, select Framed and click Add to add the condition to the Current Condition Set.

Step 5 Under Results, select the access service that was created in Create an 802.1x Access Service section. Click Ok. Click Save Changes.

Step 6 Finally: Launch AnyConnect and get connected.

The following dot1x and MAB port configuration was found to provide a satisfactory experience with most thin clients: interface GigabitEthernet0/10 switchport access vlan XX switchport mode access dot1x mac-auth-bypass dot1x pae authenticator dot1x port-control auto dot1x timeout tx-period 2 spanning-tree portfast

Appendix 3 – QOS settings in VXI Many applications do not mark traffic with DSCP values. For even those that do, the marking may not be appropriate for every enterprise's priority scheme. Therefore, you should perform hardware-based classification (using a Cisco Catalyst® or Cisco Nexus® Family switch) instead of software-based classification. In testing, the markings were implemented on a Cisco Nexus 1000V Switch whenever possible. See below for an configuration example used during testing of Cisco VXI system

Classification: ip access-list RDP permit tcp any eq 3389 any ip access-list PCoIP-UDP permit udp any eq 50002 any ip access-list PCoIP-TCP permit tcp any eq 50002 any ip access-list PCoIP-UDP-new permit udp any eq 4172 any ip access-list PCoIP-TCP-new permit tcp any eq 4172 any ip access-list ICA permit tcp any eq 1494 any ip access-list View-USB permit tcp any eq 32111 any ip access-list MMR

Page 57: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 53

permit tcp any eq 9427 any ip access-list NetworkPrinter permit ip any host 10.1.128.10 permit ip any host 10.1.2.201 ip access-list CUPCDesktopControl permit tcp any host 10.0.128.125 eq 2748 permit tcp any host 10.0.128.123 eq 2748

Class-maps: class-map type qos match-any CALL-SIGNALING match access-group name CUPCDesktopControl class-map type qos match-any MULTIMEDIA-STREAMING match access-group name MMR class-map type qos match-any TRANSACTIONAL-DATA match access-group name RDP match access-group name PCoIP-UDP match access-group name PCoIP-TCP match access-group name PCoIP-UDP-new match access-group name PCoIP-TCP-new class-map type qos match-any BULK-DATA match access-group name View-USB match access-group name NetworkPrinter

Policy-map: policy-map type qos pmap-HVDAccessPort class CALL-SIGNALING set cos 3 set dscp cs3 ! dscp = 24 class MULTIMEDIA-STREAMING set cos 4 set dscp af31 ! dscp = 26 class TRANSACTIONAL-DATA set cos 2 set dscp af21 ! dscp = 18 class BULK-DATA set cos 1 set dscp af11 ! dscp = 10

Apply policy-map to the switch port to which the hosted virtual desktop (HVD) virtual machine connects: port-profile type vethernet VM240 description Port profile for View HVD VM access vmware port-group switchport mode access switchport access vlan 240 no shutdown state enabled system vlan 240 service-policy input pmap-HVDAccessPort

Nexus 1000v QoS information:

http://www.cisco.com/en/US/partner/docs/switches/datacenter/nexus1000/sw/4_0/qos/configuration/guide/qos_2classification.html#wp1067764

Page 58: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 54

Note These examples are meant to be guidelines for deploying QoS in a Cisco VXI network and should not be applied without consideration given to all traffic flows within the enterprise.

In a campus network, the bandwidth is high enough so that contention for the resources should be minimal. However, slower connections in a branch WAN router network need to be examined. Here at the egress point from the high-speed connections of the branch-office LAN to the slower-speed links of the WAN is where bandwidth contention is likely to occur. Service policies that constrain the amount of bandwidth that is dedicated to a given protocol are defined and applied at this point. These same queuing and bandwidth configurations can be placed anywhere there is a concentration of Cisco VXI endpoints, to enforce the appropriate response in case of traffic congestion. Below is an example of Bandwidth Services Policies used during Cisco VXI system testing.

Class Maps - defining the buckets: class-map match-any BULK-DATA match dscp af11 af12 af13 class-map match-all NETWORK-CONTROL match dscp cs6 class-map match-all MULTIMEDIA-CONFERENCING match dscp af41 af42 af43 class-map match-all VOICE match dscp ef class-map match-all SCAVENGER match dscp cs1 class-map match-all CALL-SIGNALING match dscp cs3 class-map match-all TRANSACTIONAL-DATA match dscp af21 af22 af23 class-map match-any MULTIMEDIA-STREAMING match dscp af31 af32 af33

Policy Maps - Assigning the bandwidth per bucket: policy-map WAN-EDGE class VOICE priority percent 10 class NETWORK-CONTROL bandwidth percent 2 class CALL-SIGNALING bandwidth percent 5 class MULTIMEDIA-CONFERENCING bandwidth percent 5 random-detect dscp-based class MULTIMEDIA-STREAMING bandwidth percent 5 random-detect dscp-based class TRANSACTIONAL-DATA bandwidth percent 65 random-detect dscp-based class BULK-DATA bandwidth percent 4 random-detect dscp-based class SCAVENGER bandwidth percent 1 class class-default bandwidth percent 25 random-detect

Page 59: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 55

Cisco VXI thin-client endpoints do not typically provide the capability to mark the session traffic. Therefore, the same marking that was performed on the Cisco Nexus1000V in the data center for outbound desktop virtualization traffic must be performed at the branch office on behalf of the endpoints for the traffic returning to the data center virtual machine. Below is an example of a branch switch configuration used during Cisco VXI system testing.

Endpoint Classification: ip access-list RDP permit tcp any eq 3389 any ip access-list PCoIP-UDP permit udp any eq 50002 any ip access-list PCoIP-TCP permit tcp any eq 50002 any ip access-list PCoIP-UDP-new permit udp any eq 4172 any ip access-list PCoIP-TCP-new permit tcp any eq 4172 any ip access-list ICA permit tcp any eq 1494 any ip access-list View-USB permit tcp any eq 32111 any ip access-list MMR permit tcp any eq 9427 any ip access-list NetworkPrinter permit ip any host 10.1.128.10 permit ip any host 10.1.2.201 ip access-list CUPCDesktopControl permit tcp any host 10.0.128.125 eq 2748 permit tcp any host 10.0.128.123 eq 2748

Class-maps: class-map type qos match-any CALL-SIGNALING match access-group name CUPCDesktopControl class-map type qos match-any MULTIMEDIA-STREAMING match access-group name MMR class-map type qos match-any TRANSACTIONAL-DATA match access-group name RDP match access-group name PCoIP-UDP match access-group name PCoIP-TCP match access-group name PCoIP-UDP-new match access-group name PCoIP-TCP-new class-map type qos match-any BULK-DATA match access-group name View-USB match access-group name NetworkPrinter

Policy-map: policy-map type qos pmap-HVDAccessPort class CALL-SIGNALING

Page 60: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 56

set cos 3 set dscp cs3 ! dscp = 24 class MULTIMEDIA-STREAMING set cos 4 set dscp af31 ! dscp = 26 class TRANSACTIONAL-DATA set cos 2 set dscp af21 ! dscp = 18 class BULK-DATA set cos 1 set dscp af11 ! dscp = 10

Page 61: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 57

Appendix 4 – CUPC and Deskphone control

How to deliver a UC video/voice call solution using deskphone control in a hosted virtual desktop environment

This section will describe the required components and necessary steps to achieve a basic Cisco Unified Personal Communicator (CUPC) environment (IM, directory lookup and voice/video calls) running in a Citrix XenDesktop hosted virtual desktop (HVD) deployment.

The required components are listed below:

- Cisco Unified Communications Manager (Cisco UCM) 7.1(5) or later

- Cisco Unified Presence Server 8.0 or later

- Cisco IP phones 9971 or 9951 with USB video camera (Phone load <9-1-0VD-6>)

- VXC-2112 clients

- LDAP server (Microsoft Active Directory is used in this example)

- Citrix XenDesktop 5

Cisco Unified Communications Manager

Delivering the UC experience to XenDesktop HVD users can be accomplished on either virtualized Cisco UCM or MCS server based Cisco UCM deployments. For details on virtualizing your Cisco UCM see http://www.cisco.com/en/US/partner/docs/voice_ip_comm/cucm/virtual/servers.html

Cisco UCM administration does not require any extra steps or upgrades to achieve UC with Citrix XenDesktop. The provisioning and assignment of users, devices and deskphone control remains the same as if the deployment of CUPC was installed on regular laptops, but instead the CUPC application will be installed on the users Hosted Virtual Desktop (Note: CUPC is not supported in a Hosted Shared Virtual Desktop Environment). Cisco UCM must be integrated to Cisco Unified Presence server (CUP) in order to deliver CUPC sign-in, instant message, directory look-up and deskphone control features. To integrate Cisco UCM to CUP follow the steps below:

• User and Device Configuration on Cisco Unified Communications Manager

http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dgcucm.html#wp1099013

• Configure the Presence Service Parameter

http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dgcucm.html#wp1063445

• Configure the SIP Trunk on Cisco Unified Communications Manager

http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dgcucm.html#wp1063383

• Configure the SIP Trunk Security Profile for Cisco Unified Presence

http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dgcucm.html#wp1050014

• Configuring the SIP Trunk for Cisco Unified Presence

Page 62: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 58

http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dgcucm.html#wp1063105

• Create Deskphone control application user as an application user on Cisco UCM (required for deskphone control)

This user is created on CUCM as a “Application User” and must match the settings on CUPC “Desk Phone ControlSettings”

• Verifying That the Required Services are Running on Cisco Unified Communications Manager

http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dgcucm.html#wp1050114

For full details on how to configure Cisco Unified Communications Manager for Cisco Unified Presence see: http://www.cisco.com/en/US/partner/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dgcucm.html#wp1063445 (Section: Configuring Cisco Unified Communications Manager for Integration with Cisco Unified Presence)

Page 63: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 59

Each Cisco UCM end user that will use CUPC must be properly licensed. For instructions on how to license your CUPC users see: http://www.cisco.com/en/US/partner/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dglic.html#wp1081264

For all licensing requirements see: http://www.cisco.com/en/US/partner/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/dglic.html#wp1081264 Cisco Unified Presence server As with Cisco UCM the Cisco Unified Presence server can be installed on either a virtualized environment or MCS server based deployment. Also, CUP administration remains the same as if it were installed to service a laptop or desktop environment (non-hosted virtual desktop environment). To provision directory lookup a LDAP server is required and must integrate to the CUP server. For details on installing CUP server is a virtual environment see http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/installation/guide/cpinvmware.html

Note LDAP to CUP integration is used for directory lookup only, for user provisioning and user authentication the LDAP server must integrate to Cisco UCM. This is outside the scope of this document but information on how to integrate LDAP to Cisco Unified Communications Manager can be found here: http://www.cisco.com/en/US/partner/docs/voice_ip_comm/cucm/admin/8_5_1/ccmcfg/bccm-851-cm.html

Follow the steps below to provision and assign features to CUPC users:

• Configure CUCM Publisher

This value is configured during the Cisco Unified Presence installation process. If this field needs to be changed see: http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/installation/guide/cppostins.html#wp1075065

• Configure Cisco Unified Presence settings

Page 64: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 60

• Configure Presence Gateway

You must configure Cisco Unified Communications Manager as a Presence Gateway on Cisco Unified Presence to enable the SIP connection that handles the availability information exchange between Cisco Unified Communications Manager and Cisco Unified Presence. The Cisco Unified Presence server sends SIP subscribe messages to Cisco Unified Communications Manager over a SIP trunk which allows the Cisco Unified Presence server to receive availability information (for example, phone on/off hook status). On how to configure the Presence gateway see: http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/Deployment_Guide_Cisco_Unified_Presence_85_March16.pdf (search for “Presence gateway”)

• Enable Instant Messaging

You can enable instant messaging on CUP server through MessagingSettings menu. See : http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/Deployment_Guide_Cisco_Unified_Presence_85_March16.pdf (search for “instant messaging”)

• Create incoming and outgoing ACL (access list)

Access-list for both incoming and outgoing communication between CUCM and CUP server must be configured. Either IP address or FQDN (if a DNS server is deployed) can be used. For Outgoing ACL configure the CUCM server only, for the incoming ACL configure both CUCM and CUP server. These values are typically automatically populated by the CUP server during install and integration to the CUCM, but if errors occur you must enter these values manually.

Page 65: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 61

• Configure Unified Personal Communicator settings

TFTP and proxy settings must be configured under ApplicationsCisco Unified Personal CommunicatorSettings. The TFTP server will be your CUCM publisher (Or CUCM node handling CUPC application). See http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/Deployment_Guide_Cisco_Unified_Presence_85_March16.pdf (search for “Configuring the Proxy Listener and TFTP Addresses”)

• Configure LDAP host and profile

LDAP user provisioning, user authentications and directory look-up are all supported. In order to support LDAP user provisioning and authentication the LDAP integration is done with Cisco Unified Communications Manager, for directory lookup services the LDAP integration is done on the Cisco Unified Presence server. For details see: http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/Deployment_Guide_Cisco_Unified_Presence_85_March16.pdf (for CUCM LDAP integration search for “LDAP integrations”) for LDAP to CUP integration search for “Creating LDAP Profiles and Adding Cisco Unified Personal Communicator Users to the Profile and Configuring LDAP Server Names and Addresses for Cisco Unified Personal Communicator”)

• Configure DeskPhone control settings

To configure deskphone control both the CUCM and CUP server must be configured to the CTI (Computer Telephony Integration) application. For details see: http://www.cisco.com/en/US/docs/voice_ip_comm/cups/8_0/english/install_upgrade/deployment/guide/Deployment_Guide_Cisco_Unified_Presence_85_March16.pdf (search for “How to Configure CTI Gateway Settings for Desk-Phone Control on Cisco Unified Presence”)

• Assign desk phone control feature to users

Desk phone control privileges are easily assigned to users by using the CUP GUI interface

Page 66: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 62

Page 67: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 63

Citrix XenDesktop

To install Citrix XenDesktop you require virtual Windows server 2003 (XenDesktop 4) or Windows server 2008 (XenDesktop 5) for the Connection broker application (Controller). For the HVD images Windows 7 or Windows XP are supported and are installed with Citrix VDA agent. Citrix XenDesktop can be hosted by VMware ESX or ESXi, Citrix XenServer or Windows Hyper-V hypervisor environment. XenDesktop requires an Active Directory. For complete details on XenDesktop installation and configuration see http://support.citrix.com/proddocs/index.jsp?topic=/xenapp5fp-w2k8/

Appendix 5 – Netflow and Energywise

Cisco NetFlow provides statistics on packets flowing through network elements ( routers and switches ) and can be used to monitor traffic utilization in a VXI system. Netflow is supported on the following routing and switching platforms: Cisco ISR and 7200, 10000, 12000, CRS-1 Series Routers; Catalyst4k, Cat6500, and Nexus switches. Refer to the Cisco VXI CVD, for guidelines on implementing Netflow in a VXI system. Steps to enable Netflow in a VXI network: 1. Configure netflow on the network elements (router and switches)

• Set the netflow collector IP address and the netflow export version. • Enable netflow on devices and interfaces

2. Install the netflow collector as the management station. • Provision the netflow collector with IP address and SNMP attributes of Netflow enabled routers

and switches 3. Start the netflow collector to begin netflow data collection 4. Run a netflow analyzer report on the collected data The following configuration implements Netflow Data Export (NDE) on the Catalyst 6504 campus core switch : mls netflow mls netflow interface mls flow ip interface-full mls nde sender ! interface TenGigabitEthernet1/4 ip address 10.1.254.45 255.255.255.252 ip flow ingress ip flow egress ! interface TenGigabitEthernet1/5 ip address 10.1.254.41 255.255.255.252 ip flow ingress - enable netflow for inbound traffic ip flow egress - enable netflow for outbound traffic ! ip flow-export version 9 - Netflow format version 9 ip flow-export destination 10.0.128.49 2055 - IP address of the Netflow collector

Page 68: VXI Config Guide

Cisco Virtualization Experience Infrastructure (VXI) Configuration Guide

© 2011 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 64

The following sample configuration implements Netflow data export on the 7206VXR campus edge router : interface GigabitEthernet0/3 ip flow ingress - enable netflow for inbound traffic ! ip flow-export source GigabitEthernet0/1 ip flow-export version 9 - Netflow format version 9 ip flow-export destination 10.14.1.206 3000 - IP address of the Netflow collector ip flow-cache timeout active 1 ip flow-cache timeout inactive 15 snmp-server ifindex persist

Cisco's Energywise Orchestrator can be used to monitor, control, and conserve power consumption on EnergyWise enabled network elements and endpoints in a VXI deployment . VXI desktop virtualization endpoints like thick PC's and thin clients running the Orchestrator Client can be managed directly by the Energywsie Orchestrator. The power consumption on DV endpoints like VXC clients (zero clients) that use PoE can also be monitored and controlled by managing the attached port on an Energywise enabled switch. Refer to the Cisco VXI CVD, for guidelines on implementing Energywise in a VXI system. Steps for integrating Energywise in a VXI network: 1. Configure EnergyWise on the domain members (router and switches)

• Set the domain and management password on the domain members connected to the endpoints. • Configure energywise attributes on devices and interfaces connected to endpoints

2. Install the Orchestrator client on PC end points 3. Install the Orchestrator server (including the Proxy server) as the management station.

• Provision the Proxy server with the domain, password, and IP address of the primary domain member

4. Start the Orchestrator server to begin discovery of EnergyWise devices and PCs

Here is a sample configuration that enables Energwise management of the PoE+ ports (connected to VXC clients) on the Catalyst 4500E campus access switch : energywise domain Campus security shared-secret 0 cisco - sets up the domain energywise importance 70 - set the devices priority energywise name Campus_switch - sets device identity energywise keywords Campus_switch - sets device identity energywise role Campus_switch - sets the device function energywise management security shared-secret 0 cisco - sets up management communications ! interface GigabitEthernet0/3 energywise importance 60 - sets the device priority energywise role vxc-client-1 - sets the device function energywise keywords Campus.switch2.port0/3 - sets the device locations energywise name vxc-client-1 - sets the device identity